Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.4 LAccepted-AOC | ₹1.4 L Quoted ₹1.2 L | L1 | Accepted-AOC L1 |
| 2 | L2₹1.4 L+₹20,020.99 (17.2%)Rejected-Finance ETTA BHATTA MAINROAD SURAJPUR BHATGAON SURAJPUR CHHATTISGARH | DURG | CHHATTISGARH | 490001 | ₹1.4 L+₹20,020.99 (17.2%) | L2 | Rejected-Finance L2 |
| 3 | L3₹1.4 L+₹25,103 (21.5%)Rejected-Finance MISSION HOSPITAL CHOWK KEDARPUR AMBIKAPUR DIST SURGUJA CG 497001 | SURGUJA | CHHATTISGARH | 497001 | ₹1.4 L+₹25,103 (21.5%) | L3 | Rejected-Finance L3 |
| 4 | L4₹1.5 L+₹32,255 (27.7%)Rejected-Finance | ₹1.5 L+₹32,255 (27.7%) | L4 | Rejected-Finance L4 |
| Sl No | Description | Qty | Unit | MS R.P. JAISWAL L3 | M/s ARPIT ENTERPRISES L1 | M/S UMASHREE ENGINEERING L2 | Bansal Construction L4 |
|---|---|---|---|---|---|---|---|
| 1.01Item Description/ Heading | |||||||
| 1.02Wiring of light point/fan point/ exhaust fan point/ call bell point with 1.5 sq. mm. FRLS PVC insualted copper conductor single core cable in surface/recessed medium class PVC conduit, with piano type switch, phenolic laminated sheet, suitable size M.S. box & earthing the point with 1.5 sq mm FRLS PVC insulated copper conductor single core cabel etc. as required. | |||||||
| 1.03 | Group A (1-3 mtr, length of point from main supply) | 40 | Point | 533 ₹21,320 | 439 ₹17,560 | 513.07 ₹20,522.8 | 284 ₹11,360 Lowest |
| 1.04 | Group B (3-6 mtr, length of point from main supply) | 35 | Point | 618 ₹21,630 | 509 ₹17,815 Lowest | 594.95 ₹20,823.25 | 540 ₹18,900 |
| 1.05 | Group C (More than 9 mtr, length of point from Main Supply) | 30 | Point | 774 ₹23,220 | 637 ₹19,110 Lowest | 745.26 ₹22,357.8 | 840 ₹25,200 |
| 1.06 | Wiring for light/power plug with 2 x 4 sq mm FRLS PVC insualted copper conductor single core cable in surface/recessed medium class PVC conduit alogwith 1 No. 4 sq. mm FRLS PVC insualted copper conductor single core cable for loop earthing as required. | 70 | Mtr. | 175 ₹12,250 | 144 ₹10,080 Lowest | 169.08 ₹11,835.6 | 325 ₹22,750 |
| 1.07Wiring for ciruit/submain wiring alongwith earthwire with the following sizes of FRLS PVC insualted copper conductor, single core cable in surface/recessed medium clas PVC conduit as required | |||||||
| 1.08 | 2 x 1.5 sq. mm + 1 x 1.5 sq mm earth wire | 90 | Mtr. | 124 ₹11,160 | 102 ₹9,180 | 119.34 ₹10,740.6 | 75 ₹6,750 Lowest |
| 1.09 | 2 x 4.0 sq. mm + 1 x 4.0 sq mm earth wire | 90 | Mtr. | 175 ₹15,750 | 144 ₹12,960 Lowest | 169.08 ₹15,217.2 | 150 ₹13,500 |
| 1.10Supplying and fixing of follwing sizes of medium class PVC conduit along with accessories in surafce/recess including cutting the wall and making good the same in case of recessed conduit as required. | |||||||
Tender Value
₹2.3 L
EMD Value
₹2,900
Closing Date
24 Dec 2025, 5:00 pmClosed
SO EM BHATGAON AREA
OFFICE OF SO EM BHATGAON AREA
Replacement of old wiring of different rooms of surface office buildings of Manager Office Shiwani UG Mine Bhatgaon Area
2025_SECL_349030_1
SECL/Bhat/EM/e-open tender/25-26/39 dtd 08.12.2025
Open Tender
Electrical and Maintenance Works
Item Rate
30 days
SECL BHATGAON AREA
As per NIT
5 documents required · 5 mandatory
₹2,900
12 Jun 2026
9 Dec 2025
26 Dec 2025
9 Dec 2025
24 Dec 2025
9 Dec 2025
9 Dec 2025 - 17 Dec 2025
Item Description/ Heading
Wiring of light point/fan point/ exhaust fan point/ call bell point with 1.5 sq. mm. FRLS PVC insualted copper conductor single core cable in surface/recessed medium class PVC conduit, with piano type switch, phenolic laminated sheet, suitable size M.S. box & earthing the point with 1.5 sq mm FRLS PVC insulated copper conductor single core cabel etc. as required.
Group A (1-3 mtr, length of point from main supply)
Group B (3-6 mtr, length of point from main supply)
Group C (More than 9 mtr, length of point from Main Supply)
Wiring for light/power plug with 2 x 4 sq mm FRLS PVC insualted copper conductor single core cable in surface/recessed medium class PVC conduit alogwith 1 No. 4 sq. mm FRLS PVC insualted copper conductor single core cable for loop earthing as required.
Wiring for ciruit/submain wiring alongwith earthwire with the following sizes of FRLS PVC insualted copper conductor, single core cable in surface/recessed medium clas PVC conduit as required
2 x 1.5 sq. mm + 1 x 1.5 sq mm earth wire
2 x 4.0 sq. mm + 1 x 4.0 sq mm earth wire
Supplying and fixing of follwing sizes of medium class PVC conduit along with accessories in surafce/recess including cutting the wall and making good the same in case of recessed conduit as required.
Supplying and fixing follwing piano switch/socket on the existing swithc box/ cover including connections etc. as required.
5/6 amps switch
15/16 amp switch
3 pin 5/6 socket outlet
6 pin 15/16 amp socket outlet
Bell Push
Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate swithc box including connections but excluding modular plate etc. as required.
Supplying and fixing of 3 pin, 5 amp ceiling rose on the existing juction box/wooden blcok including connection etc. as required.
Supplying and fixing PVC batten/angle holder including connection etc. as required.
Supplying & fixing of following rating, double pole, (Single Phase & Neutral), 240 Volts, residual current circuit breaker (RCCB), having a sensitivity current 30 mAmps in the existing MCB DB complete with connections, testing and commissioning etc. as required
Total impact of GST for the purpose of CTC
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.05 MB
Tendernotice_1.pdf
PDF • 0.57 MB
Tendernotice_2.pdf
PDF • 1.32 MB
BOQ_361759.xls
BOQ • 0.26 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .