GE 881 EWS
GE 881 EWS C/o 56 APO
REPAIR TO FENCING, GATES, WALLS, PATH, DRAINS, PROTECTIVE WORKS AND OTHER MISC WORKS AND REPAIR TO GEYSERS, SOLAR HEATERS, ROS, CEILING FANS, EXHAUST FANS CONNECTED WORKS IN THE AOR OF STN HQ KG UNDER GE 881 EWS
2020_MES_342388_1
GE/PNH-90/2019-20
Open Tender
Civil Works
Item Rate
240 days
GE 881 EWS C/o 56 APO
AS PER TENDER DOCUMENTS
8 documents required · 8 mandatory
₹500
GE 881 EWS
₹32,000
Yes
25 Jul 2020
2 May 2020
9 Jul 2020
2 May 2020
8 Jul 2020
16 May 2020
Amount
B&R PORTION:- Dismantling posts or struts (wood, steel or R.C.C.) any section, including taking out embedded portion in concrete, brick work, masonry etc and making good disturbed ground, complete all as specified.
Dismantling posts or struts (wood, steel or R.C.C.) any section, including taking out embedded portion in natural ground and making good disturbed ground, complete all as specified.
Taking down carefully old galvanised stranded steel barbed of any description from old RCC or steel pole (each line wire to be measured) and removing frim site, complete all as specified.
Demolition of cement concrete (reinforced) of any description and in any position not otherwise specifically described (reinforement cut as required to facilitate demolition), complete all as directed by Engineer-in-Charge.
Demolition of cement concrete (un-reinforced) in ground floors and paving not exceeding 15cm thickness (below or above ground level), complete all as specified.
Demolition of brick or stone masonry, built in cement mortar including all quoins, arches, pillars etc but excluding ashlars facings, dressed stone work, complete all as specified and directed.
Dismantling wrought iron or mild steel work of any description complete all as specified and directed.
Taking down cement plaster of any description on stone or brick walls etc including racking out joints, hacking for key scrubbing down with water etc.complete all as specified.
Excavation in post holes each not exceeding 0.5 cum getting out in any type of soil, returning, filling in, including spreading, leveling, watering and well ramming earth or broken rubble mixed with earth around in layers not exceeding 25cm, watering, and removing surplus soil to a distance n exc 50m and making good surface, complete all as specified.
Plain cement concrete 1:4:8 type D-2 (using 40mm graded crushed stone aggregate) as in foundations filling and mass concrete, complete all as specified.
Mild steel work as in posts and struts in fencing including cuttings, tops to shapes, as directed, drilling, holes, notching for wire etc. flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting etc. fixed and similar work conforming to Fe-290 Gde E-165 complete all as specified.
Galvanised, 2 strand steel barbed wire 2.24mm dia, barbed with 2mm dia barbs at 75mm spacing and straining and fixing to any type of standard rails straining bolts, including securing and tying at crossings with and provision of galvanized (zinc coating 60 gram) mild steel wire, staple or steel pins, etc complete all as specified and directed.
Supply only Chain link MS galvanisd (zinc coating 60gram) fencing, any size or type, complete all as specified. Note:-Type / size of fencing holes / dia of chain link fenching shall be as approved by GE. The weight of chain link fencing shall be calculated for payment as per actual weight or standard weight as per SSR which ever is less.
Fixing only chain link fencing including line wires, any mesh, size and type to any type of standards, rails, straining bolts, etc. including provission of binding wire, complete all as specified.
Providing reinforced cement concrete type B-l, 1:2:4 (20 mm graded crushed stone aggregate) in precast posts, fencing posts, straining or terminal posts, struts etc. for fencing, average sectional area exc 100 sqcm and n exc 250 sqcm, with or without chamfered angles and flat, splayed, rounded or mitred tops as directed and fixed with & including necessary form work, complete all as specified.
RCC (nominal mix) type B-1 (1:2:4) using 20mm graded crushed stone aggregate as in columns, pillars, piers, posts and struts, complete all as specified.
Form work to sides of pillars, posts, struts piers, columns and stanchions and similar worksfor rough finished surface of concrete complete all as specified & directed.
TMT bars, 10mm dia and over, cut to length, bent to shape required including cranking, bending spirally or hooping for column, hooking ends and binding with and including mild steel wire(annealed) not less than 0.90mm dia complete all as specified.
TMT bars, 6mm to 8mm dia, cut to length, bent to shape required including cranking, bending spirally or hooping for column, hooking ends and binding with and including mild steel wire(annealed) not less than 0.90mm dia, complete all as specified.
TMT bars, 6 to 8 mm dia, cut to length, bent to shape required including cranking, bending spirally or hooping for column, hooking ends and binding with and including mild steel wire(annealed) not less than 0.90mm dia as in stirrups, complete all as specified.
Mild steel screw bolts 16-20mm dia at neck, machine made, with hexagonal or square heads at one end and screwed the other, or screwed both ends; each screwed and to be fitted with washers and one hexagonal or square nut, length of bolt exc 15cm and n exc 22.5cm long, complete all as specified and directed.
Concertina coil fencing with punched tape made to shape as directed having dia exc 450mm but nexc 600mm put on top of wall in between angle iron Y shaped post and secure with necessary binding wire complete all as specified and directed.
Brick work with sub class ‘B’ bricks straight or curved on plan exc 6m mean radius, built in cement mortar (1:6), all as specified and directed.
Walling of random rubble stone masonry brought upto course, well bonded, bedded and solidly hearted, built in cement mortar (1:6), complete all as specified and directed.
Description all as per item No.24 above, but except stone complete all as specified and directed
Boulder filling hand packed tightly (any thickness) at back of walls over arches etc. and raising (or lowering) to the required level, complete all as specified.
Rendering 20mm thick on other than fair faces of brick or stone masonry wall surfaces in cement mortar 1:4 and finished the surface even and smooth without using extra cement, complete, all as specified
15mm thick cement plaster rendering in CM 1:4 on fair faces of bricks or concrete surfaces & finishing the surface even and smooth without using extra cement, complete all as specified.
15mm thick rendering in CM 1:6 on other than fair faces of brick or stone masonry wall surfaces & finishing the surface even and smooth without using extra cement, complete all as specified.
Raking out joints / pointing to random rubble or polygonal rubble uncoursed or brought up to courses build in cement mortar, complete all as specified and directed.
Raised pointing to random rubble masonary, or polygonal rubble, uncoarsed or brought upto courses in cement mortar 1:4, complete all as specified and directed.
Applying three coats of white wash including preparation of newly plastered surfaces of wall complete all as specified.
Preparation of newly plastered or unplastered surfaces of wall and applying two coats of cement base paint, complete all as specified.
Mild steel work conforming to Fe-290 (Gde E-165) as in grills, gratings etc. with ends of bars shouldered and/ or rivetted or forged into spikes; framed guard bars, and similar works, complete all as specfied.
Applying two coats of synthetic enamel paint of Ist quality over a coat of red oxide primer to new or previously untreated steel surfaces over 10cm width or girth including preparation of surfaces, complete all as specified and as directed.
Pre-cast cement concrete block masonry 1:2:4 type B-1 (using 20mm graded crushed stone aggregate) with solid blocks, exc. 10cm in width and setting in cement mortar 1:4, complete all as specified.
Plain cement concrete 1:3:6 type C-1(using 20mm graded crushed stone aggregate) as in surface channels and drains, complete all as specified.
Extra for forming fair finished drain or channel 30cm inner girth in cement concrete using extra cement including forms, moulds, mitred/stopper ends etc complete all as specified.
25 mm thick PCC 1:2:4 type B-0 (using 12.50mm graded crushed stone aggregate) as in sub base floor finishing surface even and fair, complete all as specified.
Chequered cement concrete tiles 300x300x 25mm thick, set & jointed in neat cement slurry in floors and pointed with equal proportion of white and grey cement and no pigments, laid over and including 20mm thick screed bed in CM 1:6, complete all as specified and directed.
RCC (nominal mix) 1:2:4, type, B-1 (using 20mm graded crushed stone aggregate), as in slab supported on walls, columns in floors, roofs, landings, balconies and in shelves, complete all as specified.
Form work to soffits of suspended slab such as roof slabs, floor slabs, landings and similar work not exceeding 200mm thick for rough finished surfaces of concrete, complete all as specified.
Plain cement Concrete 1:3:6 type-B1 (using 20mm graded crushed stone aggregate) as in copings, hold fasts plinth band, bed blocks, benching and like slightly rounded or chamfered angles as directed including necessary form work, complete all as specified.
75mm thick PCC 1:4:8 type D-2 (using 40mm graded crushed stone aggregate) as in sub base to flooring/path etc, complete all as specified and directed.
Endura industrial joint free coloured tiles 10-15mm thick (square/rectangular) area of each tile n. exc 0.11Sqm as in foot path, parking area etc, set & jointed in neat cement slurry in floors and pointed in white or coloured cement to match the shade of tiles, laid over and including 15mm thick screed bed in CM 1:4, complete all as specified and directed.
Machine pressed precast concrete interlocking paver block (reflective type) any shape and size confirming to IS-15658-2006 of 60mm thickness M-35 grade, laid jointed & pointed with grey cement and pigments, with & including 25mm thick sand filling under pavers and paking the joints of paver block with sand including watering and consolidation all as specified and directed by Engr-in-Charge.
PVC (SWR) pipes 110mm dia any length single socketed with rubber ring joint laid in trenches/floors, complete all as specified and directed.
Mild steel bands, straps, supports or stays for rainwater, ventilating pipes, including bolts, if required: hooks (stay), heavy, for large gates; hook and pintle hinges: large hasps and staples; chains; hand made sliding bolts; clamps; hold fasts; wall ties; hooks for hanging fans; plain angle cleats for securing purlins to wood trusses or rafters; knee piece inserts; two way and three way straps, plate washers and similar small articles conforming to Fe-290 Gde-E-165 complete all as specified and directed.
E&M PORTION:- Repair of electric water heater (Geysers) of capacity 25 ltrs storage type including disconnecting of electric & water connections and taking out inner shell from outer cover, removing the thermostat switch, geyser element and geyser assembly etc, cleaning internally and externally including checking for leakage in geyser tank and rectifying the same by soldering / brazing, replacement of unsv accessories like inner shell, geyser element, themostate switch, gasket, nuts, bolts and clamps etc and Re - assembling the geyser and mounting on the grouted bolts and connecting with electric and water supply system and testing on complete to the entire satisfaction of the Engineer- in- Charge . (Unserviceable accessorise like inner shell, thermostat switch, geyser element and geyser assembly shall be measured and paid separately , if replaced as required under respective items).
Description all as per Srl Item No.-49 above but geyser of capacity 35/50 Litres, complete all as specified and directed.
Supply only inner shell stainless steel for storage type water heater 25 Litres capacity to match the existing model of geysers all as specified and directed by Engineer - in- Charge. Make : Same as per existing make of geyser and as approved by GE.
Description all as per Srl Item No.-51 above but for geyser of capacity 35 Litres, complete all as specified and directed.
Description all as per Srl Item No.-51 here in before but for geyser of capacity 50 Litres, complete all as specified and directed.
Supply only heating element push type, 1500 watt of triangular shape, conforming to ISI with rubber washers with clamps, complete all as specified and directed by Engineer - in – Charge.
Description all as per Srl Item No.-54 above but 2000 watt, complete all as specified and directed.
Supply only thermostat switch suitable for storage type geysers ranging 60 degree to 90 degree adjustable type operation on 240 Volts, complete all as specified and directed by Engineer - in - Charge. Make : Bajaj, Spherehot, Racold / other ISI make as approved by GE to match with existing make.
Supply only 15mm PVC connection wire woven with nickel plated brass adopter, both sides threaded, in standard length of 30cm to suit the size of geysers complete all as specified and directed by Engineer - in - Charge.
Supply only Neon lamp indicator red colour in circular / rectangular shape as suitable and as per existing model complete all as specified and directed by Engineer - in - Charge.
GI tubing, medium grade in short lengths with all fittings such as elbow, tee, socket, nipple, reducing socket, reducing elbow, reducing tee including guttees / saddles etc of size 15 mm bore and fixed to wall / floor / ceiling including connection to mixing arrangements of hot / cold water and making good disturbed surfaces all as specified and directed by Engineer - in – Charge.
Taking down and refixing of after spray painting to geysers of 25 litres capacity with one coat of synthetic enamel white paint externally after preparation of surfaces including writing MES numbers with black paint in 25mm size letters, all as specified and directed by Engineer - in – Charge
All as per Srl Item No. 60 above but geysers of 35/50 lires capacity all as specified and directed by Engineer - in - Charge.
Replacement GM stop cock of 15mm bore, ISI marked as per sample all as specified and directed by Engineer - in – Charge.
Replacement of 3 core flexible copper conductor cable of size 2.5 sqmm all as specified and directed by Engineer - in – Charge. Make : Paragon, Kalinga, Plaza
Rplacement of top plug 3 pin, 15 Amps, all as specified and directed by Engineer - in – Charge.
Cleaning storage tank of solar heating system of any capacity / size along with complete glass tubes for inside, outside/solar panel all as directed for smooth and efficiant function of system. Note :- 1. Any damage including to glass parts / solar tube/solar panel as solar water heating system during the cleaning process will be make good / replaced by contractor, cost of the same deemed to be included in the rate quoted by contractor . 2. All rubber parts or minor hidden parts such as PVC ellbow, joint, plug etc shall be replaced by contractor for effeciant functioning of system and cost of the same deemed to be included in the rate quoted by Contractor.
Removing old paint from the complete structure related to solar water heating system, by scrubbing with emery paper, applying one coat of red oxide piant and two coat of super enamelled paint of branded company (colour of paint as approved by GE), complete all as specified.
Cleaning of HDPE water storage tank from inside and outside for solar water heating system for smooth and efficient functioning of system & removing the scale / dirt from inlet / outlet pipe complete as per direction of Engr in charge.
Replacement of heating element 2 KW ISI marked of solar water heater of size 150 Ltr to 300 Ltr, complete all as directed by Engr in charge. Note :- Make and model of heating element shall be as per sample on site for solar water heating system.
Replacement of tharmostate switch suitable for solar water heater of size 150 Ltr to 300 Ltr , complete all as directed by Engr in charge. Note:- Make and model of thermostate shall be as per sample available at site to sait the solar water heating system.
Taking down ceiling fans of any type and size after disconnecting from existing ceiling rose to connector and clamp hooks and tronsportation to work shop, cleaning externally, dismantling and examining the rotor, stator, bearings, bushes, winding etc; for serviceability and repairing/replacing the defective parts subsequently oiling, greasing, assembling, testing for proper functioning, checking for safety security and proper locking, transporting back to building/site from work shop, hanging and connecting the electrical connections, testing for noise free smooth running etc. as directed.
Taking down old unserviceable rusted ceiling fan blades and providing new ceiling fan blades with fixing new screws as appropriate shape and size suitable for ceiling fan of any make and size 1200mm sweep complete all as specified and as directed
Taking down old unserviceable rusted ceiling fan blades and providing new ceiling fan blades with fixing new screws as appropriate shape and size suitable for ceiling fan of any make and size 1400mm sweep complete all as specified and as directed
Taking out existing worn out nut, bolt, rubber bush, cotter pin, and supply and fix new metallic clamps, rubber bush, nut bolt, washer and cotter pin and for various types of ceiling fans to complete the repair work all as directed.
Painting of ceiling fans along with blades of any make/model of size 1200 to 1400mm sweep with spray paint white in colour supper enameled paint, writing MES No. in 20mm letter size with black paint etc complete all as specified and as directed.
Taking out defective/worn out bearing of any make and supply and fix new bearing suitable for various makes of ceiling fans of size 1200 to 1400mm sweep complete all as specified and as directed..
Taking out defective capacitor and supply and fix new capacitor of 2.5 mfd of approved make for various makes of ceiling fans complete all as specified and as directed..
Taking out worn out Gun metal bush and supply and fix new Gun metal bush for various makes of ceiling fans of size 1200 to 1400mm sweep complete all as specified and as directed..
Taking out defective/burnt out windings of ceiling fans of various makes of size 1200 to 1400mm sweep working on 230/250 volt single phase AC supply and rewinding with supper enamelled new copper wire of appropriate gauge including varnishing with good quality varnish' baking up, reassembling the fan, testing including replacement of connector, flexible wire of suitable size, complete all as directed.
Taking out rusted/defective down rod and supply and fix new down rod of medium grade GI tubing 15mm bore having holes and threading at ends as per site requirement complete all as specified and as directed.
Taking down exhaust/wall mounted fans of any type and size after disconnecting the connections from existing ceiling rose to connector and transportation to work shop, cleaning externally, dismantling and examining the rotor, stator, bearings/bushes, winding etc for serviceability and repairing/replacing the defective parts subsequently oiling, greasing assembling, testing for proper functioning, checking for safety security and proper locking, transporting back to building/site from work shop, hanging/fixing and connecting the electrical connections, testing for noise free smooth running etc; complete all as as directed.
Painting of exhaust fans along with blades of any make/model of size 225 to 380mm sweep with spray paint black/existing colour supper enameled paint, writing MES No. in 20 mm letter size with white paint etc including prepation of old painted surface, complete all as specified and as directed.
Description all as per item No. 81 above but of size 450mm sweep.
Taking out defective/worn out bearing of any make and supply and fix new bearing suitable for various makes of exhaust fans of size 225/380mm sweep complete all as specified and as directed.
Description all as per item No. 83 above but of size 450mm sweep.
Taking out defective capacitor and supply and fix new capacitor of 4 mfd of approved make for various makes of exhaust fans complete all as specified and as directed.
Taking out defective/burnt winding of exhaust fans of various makes of size 225 to 380mm sweep working on 230 to 250 Volts, single phase, AC supply, transporting to workshop and rewinding with supper enameled new copper wire of appropriate gauge including varnishing with good quality varnish baking up, reassembling the exhaust fan, testing, replacement of connector, flexible copper wire of suitable size complete all as specified and as directed.
Description all as per item No 86 above but of size 450mm sweep.
Taking down unsv RO water purifier system, servicing the same complete by means of cleaning all pipes replacing unsv PVC connections, joints, elbow etc complete upto the entire satisfaction of work, complete all as specified. Note :- Replacement of unsv parts apart from mentioned above will be measured and paid seperately.
Replacement of pressure booster pump suitable for any type/capacity of RO, 24 volt DC, as per existing make all as specified & direct by Engr-in-charge.
Replacement of primary sedimenation filter suitable for any type/capacity of RO, as per existing make all as specified & direct by Engr-in-charge.
Replacement of post silver activated carbon cartridge for improvement of water taste, as per existing make all as specified & direct by Engr-in-charge.
Replacement of membrane catridge suitable for any/capacity of RO water purifier Make:- aquagauard or equivalant etc all as specified & directed.
Replacement of SMPS 24 volt DC adopter suitable for any/capacity of RO water purifier as per existing make, complete all as specified & directed.
Replacement of Solenoid switch (water level controler) suitable for any/capacity of RO water purifier as per existing make all as specified & directed
M/S MANHAS ENTERPRISES
M/S Farooq Ahmed Bhat
MAQSOOD AHMED
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .