| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹31.5 LAccepted-AOC RZ 18 260 WEST SAGARPUR NEAR MCD SCHOOL NEW DELHI 110046 | NEW DELHI | NEW DELHI | DELHI | 110046 | L1 | Accepted-AOC Being L1 Bidder | |
| 2 | L2₹31.7 L+₹19,460 (0.62%)Rejected-AOC E 73 FF GALI NO 17B SADH NAGAR PALAM COLONY NEW DELHI 110045 | SOUTH WEST DELHI | DELHI | 110045 | L2 | Rejected-AOC Not L1 Bidder | |
| 3 | L3₹33.8 L+₹2.4 L (7.55%)Rejected-AOC H NO 28 FIRST FLOOR E BLOCK KARMPURA WEST DELHI 110015 | WEST DELHI | DELHI | 110015 | L3 | Rejected-AOC Not L1 Bidder | |
| 4 | L4₹35.2 L+₹3.8 L (12.0%)Rejected-AOC | L4 | Rejected-AOC Not L1 Bidder | |
| 5 | L5₹36.4 L+₹4.9 L (15.6%)Rejected-AOC | L5 | Rejected-AOC Not L1 Bidder |
Tender Value
₹41.4 L
EMD Value
₹82,800
Closing Date
24 Jan 2024, 6:00 pmClosed
GE (U) WATER SUPPLY
GE (U) WATER SUPPLY DELHI CANTT
REPAIR/MAINT OF SUBMERSIBLE PUMP SETS, CLEANING OF UG SEWAGE WELLS AND CONNECTED WORKS IN THE AREA OF AGE (U) WATER SUPPLY NO III UNDER GE (U) WATER SUPPLY DELHI CANTT -10
2023_MES_634520_1
GE/WS/IFA-118/Token-73 OF 2023-24
Open Tender
Civil Works
Item Rate
180 days
GE (U) WATER SUPPLY
AS PER NIT AND TENDER DOCUMENTS
6 documents required · 6 mandatory
₹500
GE (U) WATER SUPPLY
₹82,800
Yes
14 Feb 2024
27 Dec 2023
26 Jan 2024
27 Dec 2023
24 Jan 2024
11 Jan 2024
Amount
Disconnecting electric connections from LT control panel and starter of submersible pump set of size 2 to 15 HP and removing the pipe line connections from discharge side and taking down/out submersible pump set along with column pipe from bore well with the help of chain pully block including transportation to workshop for repairs and back and lowering of same pump in bore well after repairs and replacement of rusted nuts, bolts, washers, rubber gasket etc including testing complete all as specified and as directed by Engineer-in-Charge. (NOTE :- If the contractor fails to repair the motor and pump within the seven days given to him the same will be got repaired through other agency by calling spot quotation at his risk and cost. charge as per provision of tender. The decision of the Accepting officer in this regard shall be final concluding and binding on the contractor.)
Labour for Opening the submersible pump set for repairing, rewinding and assembling the pump set including insulating material of any size of capacity 2 to 15 HP complete all as specified and as directed by Engg-in-charge.(Different make and size of copper winding and other spare parts will be measured under relevant items of this shedule as supply only) (Note :- Copper winding wire shall be measured and paid seperately as supply only under item no.03)
Supplying only super enamelled copper winding wire of appropriate gauge suitable upto 2 to 15 HP capacity submersible pump set complete all as specified and as directed. (Note :- Old U/s copper winding obtained from demolition shall be taken on charge in demolition/salvage register and enter page number in demolition statement. Necessary RV of weight (KG) shall be taken into account and attach with RAR/F Bill)
Supply Only following spare parts for submersible pump set of capacity 2 HP to 15 HP.:- (Note :- Old U/s material obtained from demolition shall be taken on charge in demolition/salvage register and enter page number in demolition statement. Necessary RV of weight (KG) shall be taken into account and attach with RAR/F Bill)
Bearing Bush.
Rotor Sleeve.
Water seal and cable seal
Thrust bearing
Revolving Disc
CI Connection piece
Motor GM Sand Guard
Sealing Ring
CI upper Housing
CI lower Housing
Labour only for Rotor Sleeve turning and grinding
Labour only for Remetling of Rotor, turning and balancing
Flange upper with stud and nut
Flange lower with stud and nut
Labour only for Repairing of stator stamping
Seal bush
CI Motor Base
Thrust plate
SS coupling
Coupling key
Stud and Nuts for connection piece
Labour only for balancing of rotor
T Bolt with Nut
LNK Bolt SS
Submersible Cable joint
CI Suction Chamber
CI Stage bowl
EPV Impeller
EPV Stage Bowl
Guide Bush
GM DOWL Bush
SS DOWL Sleeve
Inter ring
CI DOWL Piece
CI NRV body
Impeller key
SS pump shaft per stage
Remattling of GM Impeller and Turning
Pump sand guard
SS Distance Sleeve
EPV Defuser
Hook bolt with nut
GM Neck Ring
Mild steel stud with nut
Wire mesh
Drain plug
M & L for preparation of surfaces for painting of existing submersible pump sets of capacity 2 to 15 HP and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and as directed by Engineer-in-Charge.
Supply and fixing in replacement GI Nipple with flange welded, heavy duty 40 x 300 mm size complete all as specified and as directed.(Note for item no 6-8 :- Old U/s GI nipple obtained from demolition shall be taken on charge in demolition/salvage register and enter page number in demolition statement. Necessary RV of weight (KG) shall be taken into account and attach with RAR/F Bill)
All as per serial item No 6.00 here-in-before but of size 50 x 300 mm
All as per serial item No 6.00 here-in-before but of size 80 x 300 mm
Supply and fixing in replacement of GI column pipe, heavy grade, class 'C', 50 mm bore of 3 metre length, heavy duty, flange welded on both ends with suitable rubber gasket including nut & bolts complete all as specified and as directed . (Note :- Old U/s column pipe obtained from demolition shall be taken on charge in demolition/salvage register and enter page number in demolition statement. Necessary RV of weight (KG) shall be taken into account and attach with RAR/F Bill)
Supply and fixing in replacement of GI column pipe, heavy grade, class 'C', 80 mm bore of 3 metre length, heavy duty, flange welded on both ends with suitable rubber gasket including nut & bolts complete all as specified and as directed. (Note :- Old U/s column pipe obtained from demolition shall be taken on charge in demolition/salvage register and enter page number in demolition statement. Necessary RV of weight (KG) shall be taken into account and attach with RAR/F Bill)
S&F in replacement of submersible cable of size 2.5 Sqmm 3 Core. 1100 Volt complete all as specified and directed by Engineer-in-Charge.(Note for item 11-14 :- Old U/s cable obtained from demolition shall be taken on charge in demolition/salvage register and enter page number in demolition statement. Necessary RV of weight (KG) shall be taken into account and attach with RAR/F Bill)
All as per serial item No 11.00 here-in-before but cable of size 4 Sq mm 3 core , 1100 Volts .
All as per serial item No 11.00 here-in-before but cable of size 6 Sq mm 3 core, 1100 Volts .
All as per serial item No 11.00 here-in-before but cable of size 10 Sq mm 3 core, 1100 Volts .
Supply and fixing in replacement of Mild steel clamps in Mild steel flat of size 50mm x 6 mm with including two Nos Mild steel nut and bolts suitable for 50mm bore column pipe complete all as specified and directed..(Note for item 15-16 :- Old U/s clamps obtained from demolition shall be taken on charge in demolition/salvage register and enter page number in demolition statement. Necessary RV of weight (KG) shall be taken into account and attach with RAR/F Bill)
Supply and fixing in replacement of Mild steel clamps in Mild steel flat of size 80 mm x 6 mm with including two Nos Mild steel nut and bolts suitable for 80mm bore column pipe complete all as specified and directed.
Supply and fixing in replacement PVC insulated multistranded copper conductor wire 1100 volt, single core of size 2.50 Sq mm complete all as specified and as directed. .(Note for item 17-19 :- Old U/s copper wire obtained from demolition shall be taken on charge in demolition/salvage register and enter page number in demolition statement. Necessary RV of weight (KG) shall be taken into account and attach with RAR/F Bill)
All as per serial item No 18.00 here-in-before but cable of size 4 Sq mm 1100 Volts .
All as per serial item No 18.00 here-in-before but cable of size 6 Sq mm, 1100 Volts .
M&L for Periodical Cleaning dewatering and pumping out of existing accumulated Sewage/sludge and removing of settled down Sewage sludge cum mud/De-Silting etc of Sewage Well of size 8 mtr height x 6 mtr dia complete all as specified and as directed.
M&L for Periodical Cleaning dewatetrig and pumping out of existing accumulated Sewage/sludge of Sewage Installation and removing of settled down Sewage/ sludge cum mud/De-Silting etc of Sewage well of size 8 mtr height x 9 mtr lentgh x 7 width Notes for srl item Nos 20 and 21:- Rate quoted shall include the aspects:- (i) Diesel Driven Pump Set of appropriate capacity not less than 5/7.5 HP with operator including necessary POL required at site for De-Watering of Sewage septic water including PVC heavy duty flexible hose pipe for suction and delivery purposes . (ii) Tractor mounted storage tank of appropriate capacity not less than 1 KL with driver directly collected from the soak well and disposing the same to the location where approved by the Delhi Canttonment Board/PCB . (iii) Tractor/truck with driver for disposal of sewage sludge and POL required for the same (duly covered with necessary Tarpaulins ) and depositing the same to the location where approved by the Delhi Canttonment Board/PCB. (iv) Labour element and T&P required for removal of settled down sewage sludge/mud inside the sewage tank for scooping out from inside and below the septic/ staining sewage water inside the well and lifting the same and deposited on top and near by the sewage tank where directed and further to removal the same at the location where approved by the Delhi Cantonment Board/PCB (v) Appropriate qty of Phenyle required at site for Sterilization of sewage sludge being collected in the Sewage tank . (vi) Necessary Oxygen Mask, Gloves, Gum Boot and all other safety aspects and including necessary Phawda, Steel Bucket, Manila rope etc required at site.
M&L for CI water meter Woltman type magnetic drive class-B flanged suitable for 80mm dia pipe including taking dow old unserviceable water meter all as specified and as directed by Engr-in-Charge. (Note :- Old U/s water meter obtained from demolition shall be taken on charge in demolition/salvage register and enter page number in demolition statement. Necessary RV of weight (KG) shall be taken into account and attach with RAR/F Bill)
M&L for CI water meter Woltman type magnetic drive class-B flanged suitable for 100mm dia pipe including taking dow old unserviceable water meter all as specified and as directed by Engr-in-Charge. (Note :- Old U/s water meter obtained from demolition shall be taken on charge in demolition/salvage register and enter page number in demolition statement. Necessary RV of weight (KG) shall be taken into account and attach with RAR/F Bill)
Material and labour for painting to existing surface of NRV, Sluice valves/ strainers valves of capacity 80 to 200 mm by using spray gun with one coat of red oxide primer and two coat of synthetic enamel paints as per colour code all as specified and directed (Note :- Colour shades :- NRV colour - Black, sluice valves / Strainer - Black)
Material and labour for removing any type of old piant by paint removers or burning off by blow lamps and cleaning with scrapers, any number of coats, any width or grith from the existing centrifugal motor and pumps of capacity 15 to 75 HP and applying painting by using spray gun with one coat of red oxide primer and two coat of synthetic enamel paints as per colour code, complete all as specified and directed. (Note :- Shade of colour code :- Motor colour - dark grey, pump colour - Blue, Coupling -Black)
Excavation in trenches not exc 1.5 M wide and not exc 1.5 M in depth for pipe line, etc in any type of soil getting out and levelling of bottom surface to required level all as specified and as directed.
Returning filling in, including spreading, leveling, watering and well ramming in layers not exc 25 cm thick complete all as specified and as directed.
Removing excavated material (soil) from site to a distance not exc 50 mtrs and depositing where directed at a level not exc 1.5 mtr above the starting point complete all as specified and as directed.
M&Lfor DI special such as tees, bends of any size and radius, tapers, collers, tail pieces, caps and plugs complete all as specified and as directed for following sizes :-(Note :- Old U/s fittings obtained from demolition shall be taken on charge in demolition/salvage register and enter page number in demolition statement. Necessary RV of weight (KG) shall be taken into account and attach with RAR/F Bill)
(a) upto 150mm bore.
(b) 200mm to 300mm bore.
M&L Supplying, Laying, jointing, testing and commmisioning of DI Pipe, as per ISO - 7186 - 2011, K-7 with spigot and socketed ends centrifugally cast Class LA Push on joint laid in trenches complete including taking out of old UNSV pipe line any type all as specified and directed at site for the following sizes :- Note- Excavation & earth work for new location shall be measured & paid for seperately. : (Note :- Old U/s DI pipe obtained from demolition shall be taken on charge in demolition/salvage register and enter page number in demolition statement. Necessary RV of weight (KG) shall be taken into account and attach with RAR/F Bill)
(a) 200 mm bore
(b) 300 mm bore
Supplying, fixing, jointing & testing cast Iron Sluice Valve, ISI Marked, flanged ends drilled pressure rating PN-1.0, PD Short body confirming to IS 14846 -2000, having stainless steel spindle with cast iron operation wheel at top complete with Nuts, Bolts, washers and rubber gaskets of following sizes including taking out of unserviceable sluice valve complete all as specified and as directed. : (Note :- Old U/s sluice valves obtained from demolition shall be taken on charge in demolition/salvage register and enter page number in demolition statement. Necessary RV of weight (KG) shall be taken into account and attach with RAR/F Bill)
(a) 80 mm dia
(b) 100 mm dia
(c) 150 mm dia
(d) 200 mm dia
Supply, fixing, jointing and testing of Cast iron Non Return valve of following sizes, without by pass arrangement , Swing type, confirming to IS 5312, flanged ends, pressure rating PN 1.0 complete including taking out unserviceable NRV complete all as specified and as directed. Note:- Flanged joints complete with jointing material shall deemed to be included in the unit rate of this item. : (Note :- Old U/s NRV obtained from demolition shall be taken on charge in demolition/salvage register and enter page number in demolition statement. Necessary RV of weight (KG) shall be taken into account and attach with RAR/F Bill)
(a) 80 mm dia
(b) 100 mm dia
(c) 150 mm dia
(d) 200 mm dia
Supply & Fixing in replacement MCCB 200 Amps, 4 pole, 415 V, breaking capacity 36 KA lcu at 415 V, AC 50 Hz. Complete all as directed. (Note for item no.33-36 :- Old U/s MCCBs obtained from demolition shall be taken on charge in demolition/salvage register and enter page number in demolition statement. Necessary RV of weight (KG) shall be taken into account and attach with RAR/F Bill)
Supply & Fixing in replacement MCCB 160 Amps, 4 pole, 415 V, breaking capacity 30 KA lcu at 415 V, AC 50 Hz. Complete all as directed.
Supply & Fixing in replacement 3 pole MCCB 125 Amps, 415V, breaking capacity 30 kA Complete all as directed
Supply & Fixing in replacement 3 pole MCCB 63 Amps,415 V, breaking capacity 10 kA Complete all as directed
Supply and fixing in replacement 3 pole power contactor ML-1.5, 25 Amps suitable for fixing in existing panel complete all as specified and as directed. (Note for item no.37-38 :- Old U/s power contactor obtained from demolition shall be taken on charge in demolition/salvage register and enter page number in demolition statement. Necessary RV of weight (KG) shall be taken into account and attach with RAR/F Bill)
Supply and fixing in replacement 3 pole power contactor ML-2, 32-40 Amps suitable for fixing in existing panel complete all as specified and as directed.
Supply and fixing in replacement of over load relay, type ML 1.5 relay, range 10-16 Amp complete all as specified and as directed. (Note for item no.39-51 :- Old U/s relays obtained from demolition shall be taken on charge in demolition/salvage register and enter page number in demolition statement. Necessary RV of weight (KG) shall be taken into account and attach with RAR/F Bill)
Supply and fixing in replacement of over load relay, type ML-2 relay range 9-14Amps complete all as specified and as directed.
Supply and fixing in replacement of over load relay, type ML-2 relay range 13-21 Amps, Complete all as directed
Supply and fixing in replacement of over load relay, type ML-2 relay range 20-32 Amps, Complete all as directed
Supply and fixing in replacement single phase preventor, type VSP-II complete all as specified and as directed.
S&F in replacement of Amp meter digital type 0-100 Amps all as per existing size complete all as directed
S&F in replacement of Voltmeter digital type 0-500 Volts all as per existing size complete.
S&F in replacement of analog type time switch FM 1/ Quartz daily 240 VAC, flush mounting, 50 Hz Complete all as directed
S&F in replacement of indicating lamps (R.Y.B) LED Type all as per existing size and type Complete all as directed
S&F in replacement of current transformer 0-100 Amps all as per existing size Complete all as directed
S & F Fully automatic stat delta motor starter in sheet enclosure type, rating AC 3 duty 415V 50 Hz 3 phase, ML-1.5/MN-25 FASD relay range 13-21 Amps including taking down old starter complete complete all as specified and as directed by Engr in charge.
Supply & Fixing in replacement Fully Automatic Star-Delta starter type ML/MN either in FASD ML-2 or MN-32 FASD complete all as specified and as directed.
Excavation in trenches by cutting of road crossing, PCC hard standing for taking out /laying of pipe including making good the existing surface with same finish to match the original finish complete all as specified and directed.
Supply & fixing , install testing and commissioning of feeder pillar box ,outdoor type cubical shape,three phase, 4 wire, copper bus bar for phases and neutral made out of CRCA sheet 3.15 mm thick ,factory fabricated , CPRI approved , powder coated ,dust and vermin proof , provn for ventilation , angle iron frame and four legs of 50x50x6mm thick angle iron ,2 ft long grouted on PCC foundation of height not less than 30 cm from the ground level , grouting properly ,and of suitable size to accomodate the items mentioned below and having seperate compartment /chambers for cable gallery busbar ,switch gear etc all as specified and comprising of following including necessary cable connections to the MCCBs ,voltmeter,Ammeter and cable lugs etc . (Note:- Old U/s panel box, MCCBs, ampmeter,voltmeter,busbar,indicating lamps obtained from demolition shall be taken on charge in demolition/salvage register and enter page number in demolition statement.
M&L for plate earthing complete with galvanised copper plate electrode 600×600×3.15mm thick buried directly in ground vertically (in earth pit not less than 2.25 m below normal ground level) with the top edge of the earth plate at a depth not less than 1.5 m below normal ground level, the earth electrode surrounded by adequate quantity of charcoal dust and salt to a packed thickness of 15 cm on all sides and 20×3mm copper strip earth lead bolted (with brass nuts, bolts & check nuts) and riveted to earth plate at one end and connected to test point at the other, earth strip from top of electrode to body of equipment fixed with clamps, bolts, nuts and washer and also including necessary earth work, excavation etc and medium grade 40mm GI pipe of suitable length for protection of copper strip, 20 mm bore GI pipe light grade for watering from bottom of earth pit to top of plate electrode, complete with wire mesh, funnel and earth pit in PCC 1:2:4 type B-1 using 20 mm graded crushed stone aggregate and RCC cover as shown in electrical plate No. 3 of SSR Part-I and testing on completion complete all as specified and directed. (Note:- Old U/s copp[er plate,strips,rod obtained from demolition shall be taken on charge in demolition/salvage register and enter page number in demolition statement.
PRASAD ELECTRICALS
GE WORLD
M/s Shri Shyam Bharat Builders
B.R. Enterprises
Rahul Enterprises
Bidder Name
Rahul Enterprises
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .