| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹2.3 LAccepted-AOC AT DAKRA PO DAKRA DIST RANCHI 829205 JHARKHAND | DAKRA | RANCHI | JHARKHAND | 829205 | L1 | Accepted-AOC The L1 bidder is techno-commercially eligible and the rate quoted is reasonable and justified, which has been accepted by the Competent Authority, NK Area. | |
| 2 | L2₹2.8 L+₹88,021.55 (46.0%)Rejected-Finance AT PO DAKRA PS KHALARI DISTT RANCHI JHARKHAND 829210 | DAKRA | RANCHI | JHARKHAND | 829210 | L2 | Rejected-Finance L2 | |
| 3 | L3₹3.1 L+₹1.2 L (61.9%)Rejected-Finance ANAND NAGAR KAMRE RATU ROAD RANCHI DIST RANCHI JHARKHAND 835222 | RANCHI | JHARKHAND | 835222 | L3 | Rejected-Finance L3 |
Tender Value
₹2.1 L
EMD Value
₹2,600
Closing Date
22 Jun 2023, 5:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
SO EnM NK
GM Office, NK Area
Repair and maintenance of damaged internal electrical wiring of Regional Stores and Regional Workshop Dakra under GM Unit, NK Area
2023_CCL_281267_1
GM (NK)/EnM/e-NIT/2023-24/ 47
Open Tender
Electrical and Maintenance Works
Item Rate
14 days
GM Unit, NK Area
As per NIT
2 documents required · 2 mandatory
₹2,600
17 Aug 2023
10 Jun 2023
24 Jun 2023
12 Jun 2023
22 Jun 2023
12 Jun 2023
12 Jun 2023 - 19 Jun 2023
Amount
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with piano type switch, phenolic laminated sheet, suitable size M.S. box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc. as required.
Wiring for circuit / submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required 2 x 4 sq. mm + 1 x 4 sq. mm earth wire.
Supplying and fixing metal box of 150 mm X 75 mm X 60 mm deep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including providing and fixing 3 pin 5/6 amps socket outlet and 5/6 amps piano type switch, connection, painting etc. as required.(For light plugs to be used in non residential buildings).
Supplying and fixing metal box of 180 mm X 100 mm X 60 mm deep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including providing and fixing 6 pin 5/6 and 15/16 amps socket outlet and 15/16 amps piano type switch, connection, painting etc. as required
Supplying and fixing stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc as required
Supplying and fixing 3 pin, 5 amp ceiling rose on the existing junction box / wooden block including connection etc as required.
Supplying and fixing brass batten / angle holder including connection etc as required.
Providing and fixing following capacity TP&N disconnector fuse switch unit inside the existing panel board with ISI marked HRC fuses including drilling holes in cubicle panel, making connections, etc as required. 32 Amp TP&N.
Supplying and fixing DP sheet steel enclosure on surface / recess along with 25/32 amps 240 volts “C” curve DP MCB complete with connections, testing and commissioning etc. as required.
Supplying and fixing following piano type switch / socket on the existing switch box / cover including connections etc. as required. 5/6 amps. Switch.
Supplying and fixing following piano type switch / socket on the existing switch box / cover including connections etc as required. 3 Pin 5/6 amp socket outlet.
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required 2 x 2.5 sq. mm
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required 2 x 6 sq. mm
Supplying and fixing 20 amps, 240 volts, SPN industrial type, socket outlet, with 2 pole and earth, metal enclosed plug top alongwith 20 amps “C” curve, SP, MCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required
Supplying, installing, testing and commissioning of following capacity TPN tap off box made of 1.6mm thick sheet steel enclosure duly painted with powder coating on existing rising mains complete with TPN disconnector FSU and HRC fuses, connections, earthing etc. as required 100 A
Providing and fixing busbar 63 amps.
Providing and fixing change over switch 100 amps.
Total impact of GST for the purpose of CTC
A K ELECTRICALS
M/S OM ENTERPRISES
stage.html
html • 0.04 MB
techsummary_291211.pdf
PDF • 0.23 MB
finsummary_291211.pdf
PDF • 0.93 MB
AOC_47.pdf
PDF • 2.56 MB
BOQ Comparative Chart
xlsx • 0.01 MB
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .