| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹9.6 LAccepted-AOC | L1 | Accepted-AOC BEING L1 AND REASONABLE | |
| 2 | L2₹12.3 L+₹2.5 L (25.1%)Rejected-AOC RZ 18 260 WEST SAGARPUR NEAR MCD SCHOOL NEW DELHI 110046 | NEW DELHI | NEW DELHI | DELHI | 110046 | L2 | Rejected-AOC NOT BEING L1 | |
| 3 | L3₹12.8 L+₹2.9 L (29.4%)Rejected-AOC WZ 576 577 NANGAL RAYA NEW DELHI 110046 | NEW DELHI | NEW DELHI | DELHI | 110046 | L3 | Rejected-AOC NOT BEING L1 | |
| 4 | L4₹13.5 L+₹3.6 L (36.9%)Rejected-AOC | L4 | Rejected-AOC NOT BEING L1 | |
| 5 | L5₹13.5 L+₹3.7 L (37.1%)Rejected-AOC E 73 FF GALI NO 17B SADH NAGAR PALAM COLONY NEW DELHI 110045 | SOUTH WEST DELHI | DELHI | 110045 | L5 | Rejected-AOC NOT BEING L1 |
Tender Value
₹21.2 L
EMD Value
₹42,360
Closing Date
5 Sept 2024, 6:00 pmClosed
GE EM RR HOSPITAL DELHI CANTT 10
GE EM RR HOSPITAL, RAO TULA RAM MARG, DELHI CANTT 10
MAINT AND CLEANING OVER HEAD UG, SEMI UG, RCC PVC WATER TANK OF VARIOUS CAPACITY INCLUDING ALLIED WORKS AT AHRR UNDER GE EM RR HOSPITAL DELHI CANTT 10
2024_MES_663859_1
GE/H-18/2024-25
Open Tender
Civil Works
Item Rate
180 days
DELHI CANTT 10
AS PER TENDER DOCUMENTS
10 documents required · 10 mandatory
₹500
GE EM RR HOSPITAL
₹42,360
Yes
7 Oct 2024
4 Jul 2024
7 Sept 2024
4 Jul 2024
5 Sept 2024
18 Jul 2024
Amount
M&L mechanized cleaning of water reservoir of 3.15 lakh gallon semi UG capacity including scrapping of scales, flushing out of silt and muddy water, washing with anti bacterial solution, cleaning of walls by high pressure water jet, removal of remaining sludge and water with industrial vacuum pump to make the tank dry incl distamper existing colour, mud will be removed from the site etc complete all as directed.
All as per item No 1 here-in-before but for under ground sump reservoir of 2.30 lakh gallon capacity.
All as per item No 1 here-in-before but for under ground sump reservoir of 50000 gallon capacity.
All as per item No 1 here-in-before but for under ground sump reservoir of upto 25,000 gallon capacity. (Note for Srl Item No 01 to 04 : Site of the same will be handed over only for 06 hrs, contractor should arrange sufficient manpower & equipment to complete the work within the stipulated timeframe. Otherwise no payment will be entertained in this regard. Tank should be cleaned by prefessional team only. Water will not be provided for cleaning of tank. Time and date will be decided by Engr-in-Charge)
M&L cleaning of overhead water tank of 25,000 tank capacity including scrapping of scales, flushing out of silt and muddy water, washing with anti bacterial solution etc complete all as directed.
M&L cleaning of overhead water tank of 20,000 tank capacity including scrapping of scales, flushing out of silt and muddy water, washing with anti bacterial solution etc complete all as directed.
M&L cleaning of overhead water tank of 15,000 tank capacity including scrapping of scales, flushing out of silt and muddy water, washing with anti bacterial solution etc complete all as directed.
M&L cleaning of water tank of 10,000 tank capacity including scrapping of scales, flushing out of silt and muddy water, washing with anti bacterial solution etc complete all as directed.
M&L cleaning of water tank of 5,000 tank capacity including scrapping of scales, flushing out of silt and muddy water, washing with anti bacterial solution etc complete all as directed.
M&L cleaning of PVC water tank of 2,000 tank capacity including scrapping of scales, flushing out of silt and muddy water, washing with anti bacterial solution etc complete all as directed.
M&L cleaning of PVC water tank of upto 1,000 tank capacity including scrapping of scales, flushing out of silt and muddy water, washing with anti bacterial solution etc complete all as directed. Note for Srl Item No 05 to 11. Bypass supply arrangement will be provided till the cleaning of tank and rates are deem to be included in quoted rates.
M&L cleaning of fountain of any type/size including scrapping of scales, flushing out of silt and muddy water, washing properly incl replacing of broken/damaged tiles/marbles matching with exiting one incl dismantling of pipe line and refixing after descaling and painting to pipe line and structure of existing colour incl threading, cutting, welding etc complete all as directed. Note : fountain surface and pit shall be scraped/cleaned in every month for smooth functioning.
Supply only in replacement GI fittings like Tee, nipple, tank nipple, union, elbow etc of any type/size as per site requirement complete all as directed by Engr-in-charge. Make : Unik, Jindal, Tata
S&F in replacement rotational mouled polyethylene water storage tanks of tripple layers (cylindrical vertical with closed top) hoisted and fixed in position incl tank nipple complete all as specified in SSR Part I of capacity 1000 ltr.
S&F in replacement rotational mouled polyethylene water storage tanks of tripple layers (cylindrical vertical with closed top) hoisted and fixed in position incl tank nipple complete all as specified in SSR Part I of capacity 2000 ltr.
S&F in replacement rotational mouled polyethylene water storage tanks of tripple layers (cylindrical vertical with closed top) hoisted and fixed in position incl tank nipple complete all as specified in SSR Part I of capacity 500 ltr.
S&F in replacement rotational mouled polyethylene water storage tanks of tripple layers (cylindrical vertical with closed top) hoisted and fixed in position incl tank nipple and all fittings complete all as specified capacity 5000 ltr.
S&F in replacement rotational mouled polyethylene water storage tanks of tripple layers (cylindrical vertical with closed top) hoisted and fixed in position incl tank nipple and all fittings complete all as specified capacity 10000 ltr.
M&L scraping of old written Date of Cleaning and writing a fresh Date of cleaning and capacity water tank of any capacity and height quite front to entry gate of installation with synthetic enamel paint in English letter of not less than 20 cm font size and clearly visible with eyes, complete all as directed.
S&F, in replacement float valve high pressure of PTMT with epoxy coated aluminium rod and high density plastic valve screwed for iron pipe of 50 mm bore including taking out old unserviceable valve, complete.
All as per item No 20 here-in-before but for 40 mm bore size.
All as per item No 20 here-in-before but for 25 mm bore size.
All as per item No 20 here-in-before but for 20 mm bore size.
S&F in replacement stop valves , cast copper alloy, screwed down , high pressure,with crutch or butterfly handle,screwed both ends for iron pipe or for unions and fixed suitable for 50mm bore complete.
All as per item No 24 here-in-before but for 40 mm bore size.
All as per item No 24 here-in-before but for 25 mm bore size.
All as per item No 24 here-in-before but for 20 mm bore size.
All as per item No 24 here-in-before but for 15 mm bore size.
Supply only Calcium based granular disinfectant for water treatment more stable than chlorine gas, and stronger than Bleaching powder and sodium Hypochlorite pack of 45 Kg, Plastic drum all as directed.
Supply only in replacement portable and compact water testing kit containing the test of Ph, turbidity, Total hardness, Total chlorides, residual chlorine, iron, nitrates, fluoride, bacterial test complete all as specified.
S&F in replacement of well cap delivery/suction pipe suitable for any size bore dia consisting of two parts complete with welding, screwed, locking arrangements and machinary work having provision of cut out for passing of column/delivery pipe and fabricated from MS sheet 3 mm thick all as specified and directed.
S&F, in replacement foot valves, without bypass arrangement, vertical installation, flanged type for iron pipe of 150 mm bore as per IS 4038 including taking out old unserviceable valve complete all as directed.
All as per item No 32 here-in-before but for 100 mm bore size.
All as per item No 32 here-in-before but for 80 mm bore size.
Taking out GI Tubing 50 mm bore fixed on roof and wall with and including all old fittings and connections, complete all as directed.
All as per item No 35 here-in-before but for pipe of size 40 mm bore.
All as per item No 35 here-in-before but for pipe of size 25 mm bore.
Re-fixing and laying only of old steel water tubing of 50/40 mm bore retreived under sr item No. 35 & 36 above and returning of old screw threads as required in trench/floor ,in new or old positions including descaling cleaning and fixing of fittings such as elbow sockets, union, reducer all required as directed by Engineer-in charge.
Re-fixing and laying only of old steel water tubing of 25 mm bore retreived under sr item No. 37 above and returning of old screw threads as required in trench/floor ,in new or old positions including descaling cleaning and fixing of fittings such as elbow sockets, union, reducer all required as directed by Engineer-in charge.
M&L in repair the CI Sluice valve of 150mm rising PN 1.6 as per IS;14846 including CI flange with gaskit of matching hole to fix easily to the existing system complete all as specified.
All as per srl item No 40 here-in-before but of size 100 mm bore.
All as per srl item No 40 here-in-before but of size 80 mm bore.
P S TRADERS (BID ID -3073608)
Shiv Enterprises (BID ID -3074132)
M/s SAAR ENGINEERS (BID ID -3087934)
PRASAD ELECTRICALS (BID ID -3073678)
friends associeates (BID ID -3074539)
CHOUDHARY ELECTRICAL (BID ID -3073729)
V.K. Enterprises (BID ID -3074307)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .