Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹7.7 LAccepted-AOC | L1 | Accepted-AOC BEING LOWEST | |
| 2 | L2₹8.3 L+₹28,681.50 (3.59%)Rejected-Finance | L2 | Rejected-Finance Being Not lowest | |
| 3 | L3₹8.8 L+₹84,586.50 (10.6%)Rejected-Finance | L3 | Rejected-Finance Being Not lowest | |
| 4 | L4₹9.0 L+₹95,296.50 (11.9%)Rejected-Finance 65 MATA KA MANDIR RAM NAGAR COLONY SHAHJAHANPUR 242001 UP | SHAHJAHANPUR | SHAHJAHANPUR | UP | 242001 | L4 | Rejected-Finance Being Not lowest | |
| 5 | L5₹9.5 L+₹1.5 L (18.8%)Rejected-Finance MOH HATHITHAN NIGOHI ROAD SHAHJANPUR UP 242001 | SHAHJAHANPUR | UTTAR PRADESH | 242001 | L5 | Rejected-Finance Being Not lowest |
Tender Value
Refer Docs
EMD Value
₹20,000
Closing Date
13 Sept 2024, 6:00 pmClosed
AGE (I) Fatehgarh
AGE (I) Fatehgarh
REPAIR/ REPLACEMENT OF INTERNAL ELECTRIFICATION FITTING AND FIXTURES IN MARRIED/OTM ACCN OF SLI AT FATEHGARH CANTT
2024_MES_667182_1
AGE(I)/FAT/ET-12 OF 2024-2025
Open Tender
Miscellaneous Works
Works
180 days
AGE (I) Fatehgarh
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
AGE (I) Fatehgarh
₹20,000
Yes
23 Oct 2024
22 Jul 2024
20 Sept 2024
22 Jul 2024
13 Sept 2024
6 Aug 2024
23 Jul 2024 - 5 Aug 2024
Amount
Taking down copper/aluminium point wiring of any description and any position (light, fan, socket or power point) complete, including fixture and fittings such as switches,socket, ceiling rose,lamp holder,pendants, bracket and regulator etc and removing material from site including making good disturbed surface to match with the existing surface complete all as specified and as directed .
Taking down Aluminium/copper sub main wiring and making good disturbed surfaces to match with the existing surface roof/wall/floor complete all as specified and as directed .
M&L for point wiring with 1100 volt grade PVC insulated and unsheathed 1.5 Sq mm (FRLS) multistranded copper conductor cable with continuous earth wire of 1.5 Sq mm (FRLS) multistranded copper conductor cable PVC insulated and unsheathed, drawn in & including concealed / open surface PVC rigid conduit with medium grade fittings (ISI marked) not less than 20 mm dia & 1 mm thick sunken pressed steel galvanised terminal boxes with top cover ISI marked plastic laminated hylam sheet for housing/ fixing switches etc for One light/ holder/fan/exhaust fan/ bell point controlled by one switch 5/6 Amps complete all as specified & directed. Note:- (i) The quoted rate is deemed to be included for the chases cutting. (ii) Cutting chases for concealed shall be made good with using CM 1:4 and surface finished to match the existing surface & Colour.
All as per item No 03 above but one 5 pin 5 Amp switch socket combination point on an independent board complete all as specified and as directed.
All as per item No 03 above but one 5 pin 5 Amp socket point controlled by one switch on same board complete all as specified and as directed.
All as per item No 03 here in before but for one 16 Amp 6 Pin switch socket combination independent with 2.5 Sqmm FRLS unsheathed copper conductor single core multistranded complete all as specified and as directed.
S&F Switch Piano Flush type 6 Amp single pole one way complete all as specified and as directed.
S&F Switch Socket Combination 2 in 1 flush type 6 Amp 5 Pin complete all as specified and as directed.
S&F Switch Socket Combination 5 in 1, 16 Amp flush type complete all as specified and as directed.
S&F Bell Push AC 230 volts complete all as specified and as directed.
S&F Call Bell Ding Dong AC 230 volts complete all as specified and as directed.
S&F in repair Call Bell Ding Dong AC 230 volts complete all as specified and as directed.
S&F Electronic Fan Regulator 5 stepped type complete all as specified and directed
S&F Ceiling Rose PVC/Poly carbonate isolated body three terminal AC 230 volts complete all as specified and directed.
S&F in repair of Reserve Plus Rechargeable Emergency Inverter LED Batten, 20-watt Compact 3-feet LED Tubelight, Cool Day Light complete all as specified and directed.
S&F of LED decorative wall light fixture made up of Polycarbonate, suitable for 9W TU retrofit CFL (B-22 base) including LED ball Lamp 9 Watt of colour temp 3000K & luminaire lumen >1285 lm complete all as specified and directed.
M&L for Sub Main Wiring with two single core 6 Sqmm FRLS copper conductor PVC insulated and unsheathed cable including PVC conduit medium grade (appropriate size) concealed in wall for sub main connection including 6 Sqmm FRLS insulated multistranded unsheathed copper conductor used as a earth wire to common earth and connection to earth dolly complete all as specified and as directed. ( Note :- Two runs of 6 sqmm FRLS and one run of 6 sqmm FRLS copper conductor shall be measured as one unit length.)
Supply and fixing in replacement of VTPN DB 12 way suitable for Mounting MCCB as Incomer of rating 100 Amp with suitable rated bus bar having IP-43 protection and double metal door concealed in wall including connection with aluminium thimbles as required complete all as specified and as directed.
Supply and fixing in repair MCB distribution board SPN 240 Volt 8 way with 200 Amp rated bus bar having IP-43 protection and double metal door concealed in wall including connection with alum thimbles as required complete all as specified and as directed.
S&F of MCCB 100 Amp, 16KA, 4 Pole including complete electrical connection by appropriate size of alum lugs complete all as specified and directed.
S&F of MCB SPN 40 to 63 Amp Amp 240 volt 'C' 10 KA curve complete all as specifed and directed.
S&F of MCB SP 10 to 32 Amp 240 Volt 'C' curve 10 KA complete all as specified and directed.
Taking down old unserviceable LED light fitting of any description and in any position complete all as specified and directed.
S&F of LED lights fitting 4 feet, 20 Watt, 220V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and directed.
S&F of LED light fitting mirror type with high out put diffuser 2 feet, 10 watt 220 V AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed.
S & F in repair building security LED Light 30 Watt made up pressure die-cast aluminium housing with high power LED as lighting source and lens embedded PC having top opening separate driver compartment with IP-65 protection and impact resistance of IK 07 for building secuity purpose with bracket size made of GI pipe medicum grade 40 mm dia 1.5 mtr long bend to shape as required and fixing with two nos MS Clamp of size 40x6 mm for fixing of builiding security light fittings complete all as specified and directed.
S&F in repair LED luminaire 600 mm x 600 mm, 35/36 watt, 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete all as specified and directed.
S&F in repair of suspended / surface mounted with 1X 4' LED luminaire including 15 mm dia BSP steel conducit pipe of suitable length full panel LED luminaire with white powder coated housing acting as heat shrink and frame in CRCA sheet, high efficiency LED grade diffuser, in built electronic driver duly wired up to terminal block, power consumption < 30W, luminaire lumen > 3500Lm and system efficiency > 120 lm/W, CRI>80,, colour temp - 5700 K, Ingress protection IP 20, driver efficiency > 85%, 50000 burning hours (min) as per L 70 criteria, abmient temp 0 to 500C, power factor >0.95, THD <10%, surge protection in CM - 3 KV, two stages isolated constant current operated driver with range 150 - 270 V AC and safety extra low voltage safe level < 60 V DC as per IEC standard with LM 79 & LM 80 certification complete all as specified and directed.
S&F in repair to metal plug & socket DB with metal plug and MCBs dobule pole and neutral enclosere with a two pin earth plug and socket suitable for 20 Amp complete with one single pole MCB complete all as specified and directed.
Supply and Laying cable XLPE Insulated screened PVC bedded, galvanized steel strip armoured service cable pole to building electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 25 Sqmm 4 Core complete including dismentling all as specified and directed.
S & F in of 40 mm bore GI Tubing light grade with all fittings laid across road, in trenches or across PCC drain, along electric pole or floor/wall for cable protection with suitable size of MS Clapms and nut and bolts/washer complete all as specified and directed.
Supply and laying sand with approved fine grade sand around cable in cushioning for protection of under ground cable complete all as specified and as directed. Note:- (only punned and consolidated volume to be measured)
Supply and laying kiln burnt bricks best quality locally available old size sub class 'B' bricks laid flat in trenches with axis of brick perpendicular to the axis of cable for cable protection complete all as specified and as directed.
Excavation in trenches not exceeding 1.5 mtrs wide and not exceeding 1.5 mtrs in depth for laying of cables including getting out in any type of soil complete all as specified and directed.
Returning filling in including spreading, leveling ,and well ramming, in layers not exceeding 25 cm each layer of any type of soil complete all as specified and directed
Removing surplus excavated material from site not exceeding 50 mtrs from starting point and depositing where directed at level not exceeding 1.5 mtr above the starting point complete all as specified and directed
M&L for earthing complete with galvanised steel earth plate electrode 600 x 600 x 6 mm thick, burried directly into the ground (earth pit not less than 2.25 mtr below ground level) with top edge of the plate not less than 1.5 mtr below normal ground level, connected to GI earth wire 4 mm dia by means of bolts, nuts, check nuts, and washers of galvanised iron or steel all as shown iln electrical plate No - 3 connected to earthing test point all as specified or indicated including excavation and connected earth work, PCC chamber and cover, watering pipe, funnel wire mesh but with earth lead protection pipe and test on completion after dismantling unserviceable erthing (above GL only) including dismantling of exsisting earthing complete all as specified and as directed.(Note :- On testing after completion if desired earth resistence is not obtained, the earthing will be redone at no extra cost.)
M/S Arvind Electricals (BID ID -3081072)
Vishvani Electricals (BID ID -3089630)
M/S CHAUHAN ELECTRIC WORKS (BID ID -3085816)
avon electric engineering woks (BID ID -3090275)
S B ENTERPRISES (BID ID -3095107)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .