Loading…
Loading…
Tender Value
₹23.9 Cr
EMD Value
₹23.9 L
Closing Date
3 Sept 2026, 12:30 pm
Superintending Engineer
ESDC-II, 13th Floor Shakti Bhawan Extn., 14-Ashok Marg, Lucknow
Construction of 2x40 MVA 132KV AIS S/S Koushiya Sarai, Hardoi on turnkey basis
2026_PTRCL_1174492_1
ESD-681
Open Tender
Construction Works
Turn-key
365 days
superintending Engineer ESDC-II
Please refer Tender documents.
2 documents required · 2 mandatory
₹2,950
ICICI Bank A/C No 628105038318
₹23.9 L
4 Aug 2026
4 Aug 2026
5 Sept 2026
4 Aug 2026
3 Sept 2026
4 Aug 2026
FOR 2x40MVA, UPEIDA (IMLC) AIS 132/33 KV SUB-STATION KAUSHIYA SARAI, HARDOI AGAINST SPECN. No. ESD-681
SCHEDULE OF QUANTITIES & PRICES FOR SUPPLY OF EQUIPMENTS/MATERIALS AND SUPPLY OF LIGHT LUMINAIRES FOR 2x40MVA, 132/33 KV SUB-STATION KAUSHIYA SARAI, HARDOIAGAINST SPECN. No. ESD-681
Sl. No Item/Equipments alongwith all accessories as per Specifications Unit Qty. Unit F.O.R. destn. Prices in Rs. (including Pkg, fwdg, freight & insurance charges) (w/o GST) Applicable GST Amount (Rs.) (@ 18% on Col. 5) Total Unit F.O.R. Destination Prices with GST (Rs.) (5+6) Total FOR Destination Rates with GST (Rs.) (4x7)
1.1 STATION TRANSFORMER,250KVA,36/0.415KV No. 1
2 Circuit Breaker
2.1 SF6 CB,145KV,3150A,40KA No. 6
2.2 VCB,36KV,2000A,31.5KA No. 10
3 Current Transformer (CT)
3.1 CT 145KV 800-400-200/1A,(Polymer type) 3C,40/1,0.2S No. 12
CT 145KV,400-200-100/1A,(Polymer type) 3C,40/1,0.2S No. 6
Terminal CONNECTOR, for CT,145KV,TWIN PANTHER Nos 36
JUNCTION BOX,CT,145KV No. 6
CT 36KV 800-400/1A,(Polymer type) 3C,0.2S (with Terminal Connector) No. 6
CT,36KV,400-200/1A,(Porcelean type) 2C,0.2S (with Terminal Connector) No. 24
36kV CT Junction Box No. 10
4 Potential Transformer (PT)
4.1 145 kV Potential Transformers 50 VA No.
4.2 Terminal connector for 145 kV PT Nos 12
132 kV PT Junction Boxes No. 4
36kV Potential Transformer with terminal connector 50 VA No. 6
36kV PT Junction Box No. 2
5.1 145kV 1250 Amp. Line Isolators with one earth switch (Motorised) without post insulator No. 2
5.2 145kV 1250 Amp, Bus Isolators without earth switch (Motorised) without post insulator No. 10
145kV 1250 Amp.Tandem Isolators (Motorised) without post insulator No. 9
5.4 36kV 1250 Amp,Line Isolators with Post Insulators with one earth switch No. 8
5.5 36kV1250 Amp. Bus Isolators with Post Insulators and without earth switch No. 22
5.6 36kV Drop Out Fuse Set with Post Insulator No. 2
6.1 145kV Post Insulator No. 162
6.2 36KV Post Insulator No. 15
6.3 70kN Antifog Disc Insulators No 2200
7 Surge Arrestor
7.1 120 kV Polymer type Surge Arrestor No. 12
7.2 30 kV Polymer type Surge Arrestor No. 12
8 CRP & SAS ( as per Technical specification of SAS)
8.1 Rotational under frequency Relay Panel 145KV No. 1
8.2 132 kV T/F Control & Protection Panel for 40 MVA T/F No. 2
8.3 132 kV Simplex Feeder C&R Panel No. 2
8.4 132 kV Simplex type Bus Coupler Panel SAS No. 1
8.5 132 kV Transfer Bus Control Panel (TBC) No. 1
8.6 33kV Triple Feeder C&R Panel No. 3
8.7 SAS (complete set) LS 1
8.8 Optical fibre reqd. for SAS Lot 1
9 Battery & battery charger
9.1 110 V, 200 AH Batteries complete Set lead acid Set 2
9.2 Battery Charger for 110V, 200AH Batteries Nos. 2
10 LT Switchgear
10.1 110 V DC Distribution Board No. 2
415 V AC Distribution Board No. 1
415 V AC Lighting DB Set 1
Bay Marshilling Kiosk for 132 kV Switchyard No. 4
11 Capacitor Bank & its Accessories
11.1 2x5 MVAR, 33kV Capacitor Bank Unit along with following equipment Set 2
Simplex Type Control & Relay Panel for 33kV Capacitor Bank
VCB,36KV,2000A,31.5KA
SURGE ARRESTOR,30KV
3-Phase Reactor
CT,36KV,400-200/1A,2C,0.2S (with Terminal Connector)
JUNCTION BOX,CT,36KV
ISOLATOR,36KV,1250A,W E/S (LINE ISOLATOR WITH POST INSULATOR)
ISOLATOR,36KV,1250A,W/O E/S (BUS ISOLATOR WITH POST INSULATOR)
36kV NCT Ratio 5/1A
Terminal Connector for 36kV NCT
Junction Box for 36kV NCT
PT,3 PHASE,36KV
Terminal Connector for 3-Phase PT
12 1.1kV PVC FRLS Unarmoured Copper Control Cable
12.1 2 Core x 2.5 Sq.mm Km. 15
4 Core x 2.5 Sq.mm Km. 40
6 Core x 2.5 Sq.mm Km. 20
13 1.1kV PVC FRLS Unarmoured Aluminium Power Cable
13.1 3.5 Core x 400 Sq.mm Km. 1
13.2 3.5 Core x 95 Sq.mm Km. 1
13.3 3.5 Core x 50 Sq.mm Km. 1
14 Structure & Earthing Materials
14.1 Lattice Type Galvanised Main & Auxiliary Structure with MS angles, channels, plates, nuts, bolts, step bolts, U bolts, spring washers, etc. and any other required materials MT 160
40mm MS Rod for Main Earthmat Meter 6500
40mm dia, 3 Mtr MS Earth Electrodes Nos 300
75 x 10mm Meter 2500
50 x 6mm Meter 2500
25 x 6mm Meter 2000
15 Energy Meter(SAMAST)
15.1 3P4W interface energy meter (ABT) of 0.2S class Nos 6
Metering Cubicle Nos 1
Network switch-16 Port, (14Cu+2FO) Nos 1
Data Concentrator(DCU)/Communication Gateway(IG) Nos 1
LAN Cable (average one roll per S/s 300 Mtr) KM 0.2
PVC conduit pipe-3/4" KM 0.2
OFC cable armoured(6P) along with HDPE conduit pipe 32 mm KM 0.5
15.8 LIU(Line interfacing unit) with patch chord and any other accessories for fibre cable ( to be used for extending length of ETHERNET cables) Nos 2
15.9 Switch Network 8 port, 6CU+2FO No 1
16.1 ACSR Moose Km. 4
ACSR Panther Km. 2
17 Hardware fittings
Single Tension Fittings Suitable for
17.1 ACSR Moose Nos. 120
17.2 ACSR Panther Nos. 100
Single Suspension Fittings Suitable for:
17.3 ACSR Moose Nos. 50
17.4 ACSR Panther Nos. 80
PG Clamps suitable for
17.5 Moose/ Moose Nos. 300
17.6 Moose /Panther Nos. 300
17.7 Panther / Panther Nos. 450
Bus Post Clamp suitable for
17.8 Panther Nos. 50
17.9 Twin Panther Nos. 24
17.1 Moose Nos. 12
17.11 Twin Moose Nos. 12
18 Fire fighting Equipment
18.1 Fire Extinguishe, Mech Foam 50 lit. No. 4
18.2 Fire Ext. Dry Chem, IS,2171/1985, 4.5KG Nos 4
18.3 Fire Ext. CO2, ISA 2878/1986, 22.5KG Nos 4
18.4 Fire Ext. CO2, ISA 2878/1986, 9 KG Nos 5
18.5 Fire Ext. CO2, ISA 2878/1986, 4.5 KG Nos 6
18.6 Supply of sand buckets as per tech. Specn. No. 40
Supply of sand buckets stand suitable for 10 nos. bucket as per tech. Specn. No. 4
Fire protection and alarm system comprising of smoke & heat type detectors for 132 kv S/s LS 1
19 100 kVA Silent type DG set confirming to latest MoEFCC/CPCB guidelines No. 1
20 GI perforated trays of various sizes for all cable trenches in switchyard, control room including fixing for 132 kV S/s
20.1 GI perforated cable tray (225/250 mm) Mtr. 200
20.2 GI perforated cable tray (75 mm) Mtr. 300
21 Lighting and Luminaires
21.1 Supply of Complete fitting of Street Light Luminairs with LED Lamp 110 to 130 Watt, with all accessories (make Philips/CGL/Bajaj) Confirming to IP:65 Nos. 42
21.2 Supply of Complete fitting of Post Top Lantern with all accessories with LED Lamp 40 to 45 Watt (make Philips/CGL/Bajaj) Confirming to IP:65 Nos. 10
21.3 Supply of 15W LED Lamp (make Philips/CGL/Bajaj) Nos. 15
21.4 Supply of Complete fittings of 18/20 Watt LED Tube Light (make Philips/CGL/Bajaj) Nos. 50
22 Tool & Plants
22.1 Thermovision Camera (640x480 px) SATIR/FLIR Make No 1
22.2 10 kV Digital Insulation tester (Megger or equivalent make ) No. 1
22.3 Digital Multimeter (4 1/2 digit) (Motvani or equivalent make ) No. 1
22.4 Digital Clamp-on-meter (Digital, 0-300-600A) No. 1
22.5 Earthing/Discharge Rod having, 25 sq. mm. copper cable No 6
22.6 Self Supported Aluminium Ladder as per specification No 2
22.7 Cartweel mountaed Aluminium Ladder as per standard No 1
22.8 BDV Testing kit No 1
22.9 Tank Oil Storage, 20KL 1
22.1 Earthing resistance tester (4 terminor digital type) No. 1
22.11 Earth Fault detection meter No. 1
23 Fibre Optic Terminal equipment(FOTE) SDH( STM-16)
23.1 Fote Base Equipment 4 Directions No. 1
23.2 Fote Short Haul, STM-16, 1310nm SFP Transceiver - S16.1 No. 2
23.3 Long Haul, STM-16, 1310nm SFP Transceiver- L-16.1 No. 4
23.4 Long Haul, STM-16, 1550nm SFP Transceiver- L-16.2 No. 2
23.5 E1 Interfaces (120 Ohm) ( 32 Interfaces with 2 Cards) No. 1
23.7 L2Etherner Interfaces 10/100 Base T (16 Interfaces with minimum 2 cards) No. 1
23.8 Fote Equipment cabinet for SDH and DTPC 2200mm (h) including 100mm base, w x d should be suitable for 19" or 23" Rack No. 1
23.9 Fote MDF (200 Pairs), mounted in cabinet No. 1
23.1 04 command standalone Digital Tele-Protection Cuupler (DTPC) fully equipped with necessary common cards power Supply Cards other Hardware accessories Connectors Cables Subtrack with E I path cords set of 04 etc. No. 4
23.11 VOIP Phone No 1
CCTV System for 132 kV Substation LS 1
25 Air Conditioner (AC) Unit (Hitachi/LG/O'Gen/Daikin/Voltas/Bluestar make)
25.1 2 Ton , 5 Star,Window AC along with Stablizer (5KVA) No. 12
Seal of Company Full Signature …………………………
Designation ……………
SUMMARY PRICE PROPOSAL
FOR 2x40MVA, UPEIDA (IMLC) AIS 132/33 KV SUB-STATION KAUSHIYA SARAI, HARDOI AGAINST SPECN. No. ESD-681
Sl.No. DESCRIPTION Amount (in Rs.) (including GST)
1 Total Price for Supply of Equipments and Material and Light Luminaires S -1
2 Total Price for Handling, Erection, Testing & Commissioning Charges S - 2
3 Total Price for Civil Works S-3
4 Total Price for Electrical & Civil works ([S-1]+[S-2]+[S-3])
1- Bidder is required to quote prices in this Schedule for all the individual items/sub-items.
2- Please confirm that the prices are after taking into account ITC benefits. As per section 171 of CGST act 2017 , " any reduction in rate of tax any supply of goods or services or the benefit of input tax credit shall be passed on to the recipient by way of commensureate reduction of prices. Hence supplier/ manufacture to ensure to passe the benefit of reduced prices to UPPTCL. Further prices quoted by supplier/manufacturer is subject to scrutiny under above section."
3- Evaluation of Tender shall be made with GST (present rate) on all items including supply, erection, Testing & commissioning, Spare and civil work asuming the work as Work Contract.
Seal of Company Full Signature …………………………
Designation ……………
FOR 2x40MVA, UPEIDA (IMLC) AIS 132/33 KV SUB-STATION KAUSHIYA SARAI, HARDOI AGAINST SPECN. No. ESD-681
FOR 2x40MVA, 132/33 KV SUB-STATION KAUSHIYA SARAI, HARDOI AGAINST SPECN. No. ESD-681
SI. No. Item/Equipments along with all accessories as per specification Unit Qty. Unit handling, erection, testing & commissioning charges without GST (Rs.) Applicable GST Amount (Rs.) (@ 18% on Col. 5) Unit handling, erection, testing & commissioning charges with GST (Rs.) (5+6) Total Price with GST (Rs.) (4x7)
1.1 EREC 40 MVA,132/33KV TRF Nos 2
1.2 EREC 250KVA,33/0.4KV TRF No 1
2 Circuit Breaker
2.1 EREC OF 145KV CB Nos 6
2.2 EREC OF 36KV VCB Nos 10
3 Current Transformer (CT)
3.1 EREC OF 145KV CT Nos 18
3.2 EREC OF JB FOR 145KV CT Nos 6
3.3 EREC OF 36KV CT Nos 30
3.4 EREC OF JB FOR 36KV CT Nos 10
4 Potential Transformer (PT)
4.1 EREC OF 145KV PT Nos 12
4.2 EREC OF JB FOR 145KV PT Nos 4
4.3 EREC OF 36KV PT Nos 6
4.4 EREC OF JB FOR 36KV PT Nos 2
5.1 EREC OF 145KV LINE ISO W/1ES Nos 2
5.2 EREC OF 145KV BUS ISO Nos 10
5.3 EREC OF 145KV TANDEM ISO W/1ES Nos 9
5.4 EREC OF 36KV LINE ISO Nos 8
5.5 EREC OF 36KV BUS ISO Nos 22
5.6 EREC OF 36KV DROP OUT FUSE SET No 2
6 Post Insulator
6.1 EREC OF 145KV POST INSULATOR Nos 162
6.2 EREC OF 36KV POST INSULATOR Nos 15
7 Surge Arrester
7.1 EREC OF 120KV LIGHTNING ARRESTER / SURGE ARRESTOR (POLYMER TYPE) Nos 12
7.2 EREC OF 30KV LIGHTNING ARRESTER / SURGE ARRESTOR (POLYMER TYPE) Nos 12
8 CRP & SAS (as per Technical Specification of SAS)
8.1 EREC OF UNDER FREQUENCY RELAY PANEL Nos 1
8.2 EREC OF 132KV RELAY/CONTROL PANEL PWR TRF Nos 2
8.3 EREC OF RELAY/CONTROL PANEL TBC No 1
8.4 EREC OF RELAY/CONTROL PANEL BUS COUPLER No 1
8.5 EREC OF RELAY/CONTROL PANEL FOR FDR Nos 2
8.6 EREC OF 33KV TRIPLE FDR CRP Nos 3
8.7 EREC OF SAS PANEL LS 1
8.8 EREC OF OPTICAL FIBRE FOR SAS LS 1
9 Battery & Battery Charger
9.1 EREC OF 110V BATTERY SET Set 2
9.2 EREC OF 110/48V BATTERY CHARGER No 2
10.1 EREC OF 110V DCDB No 2
10.2 EREC OF 415V ACDB No 1
10.3 EREC OF LIGHTING DIST BOARD No 1
10.4 EREC OF BAY MARSHALLING KIOSK AT 132KV SWITCHYARD Nos 4
11 Capacitor Bank & its Accessories
11.1 EREC OF COMPLETE 33KV CAPACITOR BANK 2X5MVAR IN ALL RESPECT SET 2
12.1 1.1 KV PVC FRLS Unarmoured Copper Control Cable
12.1.1 LAYING 2CX2.5SQMM UNARM CTRL CABLE including Terminations of cables (COMPLETE IN ALL RESPECT) KM 15
12.1.2 LAYING 4CX2.5SQMM UNARM CTRL CABLE including Terminations of cables (COMPLETE IN ALL RESPECT) KM 40
12.1.3 LAYING 6CX2.5SQMM UNARM CTRL CABLE including Terminations of cables (COMPLETE IN ALL RESPECT) KM 20
12.2 1.1 KV PVC FRLS Unarmoured Alluminium Power Cable
12.2.1 LAYING 3.5 core * 400 sq. mm including Terminations of cables (COMPLETE IN ALL RESPECT) KM 1
12.2.2 LAYING 3.5 core * 95 sq. mm including Terminations of cables (COMPLETE IN ALL RESPECT) KM 1
12.2.3 LAYING 3.5 core * 50 sq. mm including Terminations of cables (COMPLETE IN ALL RESPECT) KM 1
13 Structure & Earthing Material
13.1 EREC,STRUCTURES, MAIN/AUX, INCL ACCS: with MS angles, channels, plates, nuts, bolts, step bolts, U bolts, spring washers, etc. and any other required material MT 160
13.2 LAYG MS BAR 700MM-40MM DIA 40mm for Main Earthmat RM 6500
13.3 LAY,ELECTRODE,MS ROUND,40MMX3M,BLW GND 40mm Dia MS Electrode (3 M Long) Nos 300
13.4 FRESH EARTHG,W/FLAT,75X10MM RM 2500
13.5 FRESH EARTHG,W/FLAT,50X6MM RM 2500
13.6 FRESH EARTHG,W/FLAT,25X6MM RM 2000
14 Energy Meter
14.1 EREC OF ABT ENERGY METER Nos 6
14.2 EREC OF ABT ENERGY METERING PANEL with one main & one check rack No 1
14.3 INSTALLATION,DCU/GATEWAY/ETC including installation of Network Switch-16 Port, (14Cu+2 FO with FO Communication module (industrial frade), LIU (Light Interfacing Unit) with patchcord & accessories, Network Switch-08 Port, Data Concentrator (DCU)/ Communication Gateway (IG), laying of Lan Cable, PVC Conduit Pipe-3/4, OFC Cable Armoured (6P), HDPE Conduit Pipe 32mm LS 1
15 Stringing of Conductors
15.1 Stringing of Bus bars comprising of Conductors Tension & Suspension stings complete with anti fog type disc insulators, tension & suspension clamps, PG clamps, Bus post clamps, connectors, earth wires and all other required material for KM 2.5
15.2 132 KV Main Bus I & II Lot 1
15.3 132 KV Transfer Bus Lot 1
15.4 132 KV Jack Bus for
15.5 Feeder Lot 1
15.6 40 MVA Transformer Lot 1
15.7 Bus Coupler Lot 1
15.8 33 KV Main Bus Lot 1
15.9 33 KV Auxilliary Bus Lot 1
15.1 JUMPERING TRF & ASSOC. EQUIP. Baywise interconnection of equipments with specified conductors ( jumpering ) for complete substation including but not limited to: 1.40 MVA Transformer bay including 132 KV &33KV side bays 2. 132 KV Feeder Bays 3. 132 KV Bus Coupler Bay 4. 132 KV Transfer Bus Coupler Bay 5. 33 KV Feeder Bays 6. 33 KV Bus Coupler Bay 7. 33 KV Bay for station Transformer (COMPLETE IN ALL RESPECT) LS 1
16 Fire Fighting equipments
16.1 EREC OF FIRE FIGHTING SYSTEM (COMPLETE IN ALL RESPECT) JOB 1
17.1 EREC OF 100 KVA DG SET conforming to latest MoEFCC/CPCB guidelines No 1
18.1 INSTALL,TRAY,CABLE,INCL FABRICATION/ETC LS 1
19 FOTE Equipments
19.1 ERECTION/LAYING/T&C,STM-16,FOTE Erection of Fiber Optic Terminal Equipment (FOTE) SDH (STM-16) including but not limited to installation /erection of : 1. Base equipment suitable for 04 directions in subrack fully equipped with all necessary common cards, power supply cards, other hardware & accessories including 10 Nos. optical patch cords of lengths as per site requirements, DDF etc. with redundant CPU. 2. Optical Base Card for 04 directions (STM-16) 3. Short Haul & Long Haul 4. E1 Interfaces & L2 Etherner Interfaces 5. Equipment cabinet for SDH and DTPC 2200mm (Alongwith 110V to 48V DC-DC Converter) 06 VOIP Phone 7. MDF (200 Pairs), mounted in cabinet 8. 04 command standalone Digital Tele-Protection Coupler (DTPC) fully equipped with necessary common cards power Supply Cards other Hardware accessories Connectors Cables Subtrack with E I path cords set of 04 etc. (COMPLETE IN ALL RESPECT) LS 1
20 CCTV system complete in all respetcs LS 1
20.1 Air Conditioner (AC) Unit system complete in all respetcs Nos 12
21 LIGHT LUMINAIRES
21.1 OUTDOOR LIGHTING
21.1.1 PERIFERY AND ROAD LIGHTING
21.1.1.1 Supply and fixing of steel round pole 9.0 mt long in 1:4:8 cement concrete with 40mm brick ballast in size of 450x450x1900 and plastering of 300mm length of concrete above ground level No. 12
21.1.1.2 Supply of junction box of size 280x225x150mm made of 16 SWG sheet with grey painting suitable for 2x4x6 C sq mm incoming cable & 2x4x6 C sq mm out going cable fitted with 3 Nos. HRC Fuse link of 5A, Cable glands, neutral link, terminal block etc. and Fixing of junction box on M.S. round pole with the help of M.S. Clamp No. 12
21.1.1.3 Fixing of complete fitting of light luminaries with LED Lamp 110 to 130 Watt at designated height on light pole including taking out cable from junction box to light fixtures from inside pole. cable terminations and it’s testing and commissioning and earthing with 12 No. SW GI Wire No. 12
21.1.1.4 Supply & fixing of GI pipe bend of 35mm dia 'B' class 2.5 meter long and bended at one end by quarter circle in 0.5 meter for cable entry to junction box fitted on steel round pole No. 12
21.1.1.5 Painting of M.S. Round pole with first quality Asian /Nerolec/Burger paint, one coat of Red Oxide primer and two coats of Aluminium paint. No. 12
21.1.1.6 Making 3 Nos. of strips of 450mm height from plinth with Post Office red colour in bottom & top and white colour in middle on each light pole of 150mm dia on M.S. Round pole and writing No. of pole. No. 12
21.1.2 SWITCHYARD LIGHTING
21.1.2.1 Supply of junction box of size 280x225x150mm made of 16 SWG sheet with grey painting suitable for 2x4x6 C Sqmm incoming cable & 2x4x6 C sqmm out going cable fitted with 3 Nos. HRC Fuse link of 5A, Cable glands, neutral link, terminal block and Fixing of junction box on Columns with the help of 50x6mm G.I. Clamp No. 30
21.1.2.2 Supply and fixing of GI pipe bend of 35mm dia 'B' class 2.0 meter long and bended at one end by quarter circle in 0.5 meter for cable entry to junction box fitted on column No. 30
21.1.2.3 Supply and fixing of Light bend of 50mm dia GI 'B' class pipe 1.5 meter long bended at 1 meter at an angle of 300 for 250W HPSV light in Switchyard. No. 30
21.1.2.4 Fixing of complete fitting of LED 110 to 130 Watt light luminaries at designated height on Column with the help of GI clamps & Light Bend cable terminations and it’s testing and commissioning and earthing with 12 No. SW GI Wire. No. 30
21.1.3 LAWN LIGHTING
21.1.3.1 Supply & fixing of 'B'type light pole 2.5M long and fixing of cable bend pipe & its concreting in the ratio of 1:2:4 with 20mm stone granite and cement concrete in the size of 500x300x300mm including excavation, back filling, curing etc. to complete the job No. 5
21.1.3.2 Supply of Junction Box of size 180x150x100mm made of 16 SWG steel with grey painted suitable for 2x2x6 C Sqmm cable fitted 2 Nos. HRC Fuse link of 5A & 1 No. Neutral link terminal block, cable glands etc and fixing of junction box on light pole with the help of M.S. clamps and then making plinth of size 225x300x300 in the ratio of 1:2:4 cement & coarse sand with 20mm granite with JB embedded in the plinth and the top surface of plinth being tapered from all four sides of plinth with 30mm height in the centre including all associated works of finishing, plastering etc. No. 5
21.1.3.3 Supply & fixing of 50mm dia GI pipe light pole of 'B' class quality No. 5
21.1.3.4 Supply & fixing of 'J' bend of 25mm dia GI pipe of 'B' class for cable entry No. 5
21.1.3.5 Assembling and fixing of complete fitting of post top lantern with LED Lamp 40 to 45 Watt over the light poles, cable terminations, testing & commissioning etc. No. 5
21.1.3.6 Making 3 Nos. of strips of 150mm height from plinth with Post Office red colour in bottom & top and white colour in middle on each light pole of 50mm dia No. 5
21.1.4 GATE LIGHTING
21.1.4.1 Supply & fixing of junction box of size 180x150x 100mm as specified above at si.no. C_2 No. 4
21.1.4.2 Assembling and fixing of Complete fitting of post top lantern with LED Lamp 40 to 45 Watt with cable terminations, testing and ,commissioning No. 4
21.1.5 CABLE LAYING AND TERMINATIONS
21.1.5.1 Laying of 4cx2.5 sq mm copper control cable from control room to various point and for lawn lighting in excavated trench M 100
21.1.5.2 Laying of 2cx2.5 sq mm Copper control cable for lighting in switchyard periphery, road etc. in excavated trench M 500
21.1.5.3 Taking out above cable from junction box to light fittings fixed over the column by fixing GI clamps of 40x5mm flat with each crossed bracing on structures proper dressing etc M 500
21.1.5.4 Excavation of trench of size 300 x 600 mm for laying of cable, putting ganga sand & Ist class bricks over the cable and then earth filling etc. 500
21.1.5.5 Supply & fixing of Cable marker made of cast iron No. 60
21.1.2 INDOOR LIGHTING FOR CONTROL ROOM AND STORE
21.1.2.1 Wiring for light point/fan point/ Exhaust Fan point/Call bell point with 3/22, 1.5mm2 PVC insulated copper conductor in PVC conduit concealed in wall with 2.24mm dia bare copper earth continuity wire & piano type switches etc. complete in all respect. Nos. 70
21.1.2.2 Wiring for 3 Pin 5A light plug point socked outlet on existing switch board with 3/22, 1.5mm2 PVC insulated copper conductor in PVC conduit concealed in wall with 2.24mm dia bare copper earth wire continuity along with piano type switch complete in all respect. Nos. 12
21.1.2.3 Supply and fixing of metal box of size 180x100x80mm deep in recess with suitable size of white laminated sheet cover in front including providing & fixing 3 pin 15 A socket & switch connection piano type with 7/22, 4.0mm2 PVC insulated copper conductor concealed in wall with 2.24mm dia bare copper earth wire continuity complete in all respect. Nos. 8
21.1.2.4 Supply & wiring of sub main with PVC insulated copper wire of size & no. as detailed below along with 2.24mm dia bare copper earth wire continuity in PVC conduit concealed in wall complete in all respect.
21.1.2.5 2x4mm2 with 1 No. earth wire M 40
21.1.2.6 4x4mm2 with 2 No. earth wire M 30
21.1.2.7 2x1.5mm2 with 1 No. earth wire M 40
21.1.2.8 4x1.5mm2 with 2 No. earth wire M 50
21.1.2.9 Supply & fixing of angle/button holder suitable for LED Lamps complete in all respect Nos. 8
21.1.2.10 Supply & fixing of Factory Wired in-door decorative luminairs with LED Lamp for ceiling mounting with mirror optic suitable for 2x20/2x18W LED complete in all respect of category 'A' (make Philips/CGL/Bajaj) Nos. 8
21.1.2.11 Supply & fixing of factory wired in-door decorative luminairs for surface mounting with oval polystyrene diffuser suitable for 1x20/1x18 W LED Lamp complete in all respect of category 'A' make.(make Philips/CGL/Bajaj) Nos. 10
21.1.2.12 Supply & Fixing of complete set of street light luminair with LED Lamp 110 to 130 Watt complete in all respect with integral control gear of category 'A' make.(make Philips/CGL/Bajaj) Nos. 3
21.1.2.13 Supply & fixing of factory wired LED light fitting suitable for 1x20W LED complete in all respect of category 'A' make.(make Philips/CGL/Bajaj) Nos. 10
21.1.2.14 Supply & Fixing of Fancy wall bracket 1x15W LED fittings Nos. 12
21.1.2.15 Supply & Fixing of decorative ceiling luminairs for 1x10W LED Lamp complete with round twin PVC insulated flexible cord, approved holder complete in all respect with bulb for DC lighting Nos. 7
21.1.2.16 Supply & Fixing of 1200mm ceiling Fan complete with electronic regulator with double ball bearing and approved colour of category 'A' make as approved by Engineer. Nos. 10
21.1.2.17 Supply & fixing of 18" Exhaust fan of category 'A' make as approved by the Engineer. Nos. 4
21.1.2.18 Supply & Fixing of 12" Fresh Air Fan of category 'A' make as approved by the Engineer Nos. 4
21.1.2.19 Supply & fixing of 6000 capacity Desert cooler of size made of 20 SWG galvanized sheet duly wired fitted with 18" Exhaust fan of cat 'A' make and vertical pump along with stand & other thing required to complete the jobs satisfactorily. Nos. 2
21.1.2.20 Supply and fixing of Four Pole Isolator of 60/63 A. No. 1
21.1.2.21 Supply and fixing of surface/flush mounting 8 ways SPN Distribution board with MCB complete in all respect. No. 1
21.1.2.22 Supply & fixing of Call bell of approved make on white laminated sheet board including making connection etc. complete in all respect. Nos. 1
21.1.2.23 Supply & Fixing of 600x800x8mm GI plate vertically for earthing with its top at least 3M below the ground level complete with 20mm dia GI pipe & funnel for watering and one earthing lead of one No. 8 to 10 SWG GI wire within 15mm dia GI pipe up to switch board 30cm square CI frame with hinged cover masonry housing alternate layer of charcoal/coke and salt at least 150mm thick alround etc as per direction of Engineer complete in all respect Nos. 1
21.1.2.24 Supply & Fixing of Distribution box 6 bay TPNDB with 100 Amp. Isolator and 18 No. SP MCB of different capacity Havells make. Nos. 2
Seal of Company Full Signature …………………………
Designation ……………
FOR 2x40MVA, UPEIDA (IMLC) AIS 132/33 KV SUB-STATION KAUSHIYA SARAI, HARDOI AGAINST SPECN. No. ESD-681
Name of Bidder:
Bill of Quantity Name of Work :- Construction of Main Gantry, Aux. Foundation, Cable Trenches, Transformer Foundation, Firewall, Capacitor Bank, Control Room Building, Store, Sump House, Chain link fencing, Drain, Culvert, C.C. Road, Park & Plantation,Water supply works, Fire Hydrant System, O.H Tank, Tube Well Boring and Mis. Development Works etc. at 132/33 KV Sub-Station IMLC, Hardoi. (SOR 05/2024,G-4)
SI No Description Unit Qty Turnkey Qty Dept. Qty Unit Rate (Rs.) Applicable GST Amount (Rs.) (@ 18% on Col. 5) Unit Rate with GST (Rs.) (5+6) Total Price with GST (Rs.) (Rs) (4x7)
1 Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and for all lift, as directed by Engineer-in-charge. in All kinds of soil Cubic meter 2500 Cubic meter 1018
2 Excavating, supplying, stacking and filling of local earth (including royalty) by mechanical transport upto a lead of 5km also including ramming and watering of the earth in layers not exceeding 20 cm in foundation trenches, plinth, sides of foundation etc. complete for all lift. Cubic meter 48000 Cubic meter 6271
3 Supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete. Cubic meter 1500 Cubic meter 1805
4 Clearing jungle including uprooting of rank vegetation, grass, brush wood, trees and saplings of girth up to 30 cm measured at a height of 1 m above ground level and removal of rubbish up to a distance of 50 m outside the periphery of the area cleared. Cubic meter 1200 Square meter 22200
5 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:1½:3 (1 Cement: 1½ coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) Cubic meter 150 Cubic meter 1400
6 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources) Cubic meter 450 Cubic meter 923
7 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:5:10 (1 cement : 5 coarse sand (zone-III) derived from natural sources : 10 graded stone aggregate 40 mm nominal size derived from natural sources) Square meter 350 Cubic meter 24700
8 Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level :1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) Square meter 1700 Cubic meter 11500
9 Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement :1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) Cubic meter 120 Cubic meter 10
10 Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources). Cubic meter 130 Cubic meter 88.1
11 Centering and shuttering including strutting, propping etc. and removal of form for Foundations, footings, bases of columns, etc. for mass concrete Cubic meter 6000 Square meter 77
12 Centering and shuttering including strutting, propping etc. and removal of form for Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc. Cubic meter 2400 Square meter 510
13 Centering and shuttering including strutting, propping etc. and removal of form for Suspended floors, roofs, landings, balconies and access platform Square meter 500 Square meter 857
14 Centering and shuttering including strutting, propping etc. and removal of form for Shelves (Cast in situ) Square meter 50 Square meter 360
15 Centering and shuttering including strutting, propping etc. and removal of form for Lintels, beams, plinth beams, girders, bressumers and cantilevers per bag of 50kg cement used 150 Square meter 1350
16 Centering and shuttering including strutting, propping etc. and removal of form for Columns, Pillars, Piers, Abutments, Posts and Struts Cubic meter 600 Square meter 1118
17 Centering and shuttering including strutting, propping etc. and removal of form for Stairs, (excluding landings) except spiral-staircases Cubic meter 100 Square meter 356
18 Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. Mild steel and Medium Tensile steel bars Square meter 100000 Kilogram 950
19 Add for plaster drip course/ groove in plastered surface or moulding to R.C.C. projections. per cm depth per 100m 110 Meter 188
20 Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in:Cement mortar 1:4 (1 cement : 4 coarse sand) RM 1000 Cubic meter 486
21 Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in:Cement mortar 1:6 (1 cement : 6 coarse sand) Cubic meter 450 Cubic meter 363.8
22 Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in :Cement mortar 1:4 (1 cement : 4 coarse sand) Square meter 50 Cubic meter 2258
23 Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in :Cement mortar 1:6 (1 cement : 6 coarse sand) Square meter 250 Cubic meter 940
24 Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level.Cement mortar 1:3 (1 cement :3 coarse sand) Square meter 100 Square meter 1327
25 Providing edge moulding to 18 mm thick marble stone counters, Vanities etc., including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in-Charge. Marble work Square meter 50 Meter 1485
26 Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. Square meter 40 Square meter 3015
27 Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) decorative type, core of block board construction with frame of 1st class hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters. 35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws Cubic meter 25 Square meter 101.2
28 Providing and fixing ISI marked, IS : 1341, M.S. heavy weight bright finished butt hinges with necessary screws etc. complete : 125x90x4.00 mm Kg 15 each 212990
29 Providing and fixing aluminium die cast body tubular type universal hydraulic door closer (having brand logo with ISI, IS : 3564, embossed on the body, door weight upto 35 kg and door width upto 700 mm), with necessary accessories and screws etc. complete. Meter 15 each 250
30 Providing and fixing fly proof stainless steel grade 304 wire gauge, to windows and clerestory windows using wire gauge with average width of aperture 1.4 mm in both directions with wire of dia. 0.50 mm all complete. With 12 mm mild steel U beading Cubic meter 15 Square meter 746.5
31 Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. Cubic meter 75000 Kg 313
32 Providing and fixing 1 mm thick M.S. sheet sliding-shutters, with frame and diagonal braces of 40x40x6 mm angle iron, 3 mm M.S. gusset plates at the junctions and corners, 25 mm dia pulley, 40x40x6 mm angle and T- iron guide at the top and bottom respectively, including applying a priming coat of approved steel primer Cubic meter 10 Square meter 110
33 Supplying and fixing rolling shutters of approved make, made of required size M.S. laths, interlocked together through their entire length and jointed together at the end by end locks, mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete, including the cost of providing and fixing necessary 27.5 cm long wire springs manufactured from high tensile steel wire of adequate strength conforming to IS: 4454 - part 1 and M.S. top cover of required thickness for rolling shutters.80x1.25 mm M.S. laths with 1.25 mm thick top cover Cubic meter 10 Square meter 251
34 Providing and fixing ball bearing for rolling shutters. Square meter 5 Each 35
35 Providing & fixing fly proof wire gauze to windows, clerestory windows & doors with M.S. Flat 15x3 mm and nuts & bolts complete.Stainless steel (grade 304) wire gauze of 0.5 mm dia wire and 1.4 mm aperture on both sides Meter 25 Square meter 125
36 Dry brick on edge flooring in required pattern with bricks of class designation 7.5 on a bed of 12 mm mud mortar, including filling joints with Jamuna sand, with common burnt clay non modular bricks. Square meter 500 Square meter 62
37 Providing and fixing 10 mm thick acid and/or alkali resistant tiles of approved make and colour using acid and/or alkali resisting mortar bedding, and joints filled with acid and/or alkali resisting cement as per IS : 4457, complete as per the direction of Engineer-in- Charge. In dado/skirting on 12 mm thick mortar 1:4 (1 acid proof cement : 4 coarse sand) Acid and alkali resistant tile each 50 Square meter 13
38 Extra for pre finished nosing to treads of steps of marble stone. each 150 Meter 105
39 Providing and fixing 1st quality ceramic glazed floor tiles conforming to IS : 15622 (thickness to be specified by the manufacturer ) of approved make in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge in skirting, risers of steps and dados over 12 mm thick bed of cement Mortar 1:3 (1 cement: 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm including pointing in white cement mixed with pigment of matching shade complete. each 75 Square meter 155
40 Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete. Size of Tile 600x600 mm each 400 Square meter 35
41 Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing , curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. Polished Granite stone slab colour of Black, Cherry/Ruby Red or equivalent each 50 Square meter 35
42 Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes. 110 mm diaMeter each 300 Meter 95
43 Providing and fixing tiled false ceiling of specified materials of size 595x595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanized steel sections ( galvanized @ 120 grams/ sqm, both side inclusive) consisting of main "T" runner with suitably spaced joints to get required length and of size 24x38 mm made from 0.30 mm thick (minimum) sheet, spaced at 1200 mm center to center and cross "T" of size 24x25 mm made of 0.30 mm thick (minimum) sheet, 1200 mm long spaced between main "T" at 600 mm center to center to form a grid of 1200x600 mm and secondary cross "T" of length 600 mm and size 24x25 mm made of 0.30 mm thick (minimum) sheet to be interlocked at middle of the 1200x600 mm panel to form grids of 600x600 mm and wall angle of size 24x24x0.3 mm and laying false ceiling tiles of approved texture in the grid including, required cutting/making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main "T" runners to be suspended from ceiling using GI slotted cleats of size 27 x 37 x 25 x1.6 mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4 mm GI adjustable rods with galvanised butterfly level clips of size 85 x 30 x 0.8 mm spaced at 1200 mm center to center along main T, bottom exposed width of 24 mm of all T-sections shall be pre-painted with polyester paint, all complete for all heights as per specifications, drawings and as directed by Engineer-in-charge. 12.5 mm thick square edge PVC Laminated Gypsum Tile of size 595x595 mm, made of Gypsum plasterboard, manufactured from natural gypsum as per IS 2095 part I and laminated with white 0.16mm thick fire retardant PVC film on the face side and 12micron metalized polyester on the back side with all edges sealed with the face side PVC film which goes around and wraps the edges and is bonded to the edges and the back side metalized polyester film so as to make the tile a completely sealed unit. each 250 Square meter 145
44 12 mm cement plaster of mix : 1:4 (1 cement: 4 coarse sand) each 5500 Square meter 40
45 12 mm cement plaster of mix : 1:6 (1 cement: 6 coarse sand) Kg 500 Square meter 73130
46 15 mm cement plaster on rough side of single or half brick wall of mix: 1:4 (1 cement: 4 coarse sand) Square meter 600 Square meter 10
47 6 mm cement plaster of mix : 1:3 (1 cement : 3 fine sand) Each Square meter 2
48 Neat cement punning. Each 3700 Square meter 25
49 Extra for providing and mixing water proofing material in cement plaster work in proportion recommended by the manufacturers. Kg 700 Activity unit 270
50 Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade: New work (Two or more coats applied @ 1.43 ltr/10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/10 sqm) Square meter Square meter 43
51 Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade : Two or more coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture Square meter 1500 Square meter 300
52 Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. Square meter 2500 Square meter 845
53 Wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre of approved brand and manufacture, including applying additional coats wherever required to achieve even shade and colour.Two coats Meter 1500 Square meter 500
54 Providing and fixing double scaffolding system (cup lock type) on the exterior side, up to seven story height made with 40 mm dia M.S. tube 1.5 m centre to centre, horizontal & vertical tubes joining with cup & lock system with M.S. tubes, M.S. tube challies, M.S. clamps and M.S. staircase system in the scaffolding for working platform etc. and maintaining it in a serviceable condition for the required duration as approved and removing it there after .The scaffolding system shall be stiffened with bracings, runners, connection with the building etc wherever required for inspection of work at required locations with essential safety features for the workmen etc. complete as per directions and approval of Engineer-in-charge .The elevational area of the scaffolding shall be measured for payment purpose .The payment will be made once irrespective of duration of scaffolding. Square meter 300 Square meter 165
55 Fencing with angle iron post placed at required distance embedded in cement concrete blocks, every 15th post, last but one end post and corner post shall be strutted on both sides and end post on one side only and provided with horizontal lines and two diagonals interwoven with horizontal wires, of barbed wire weighing 9.38 kg per 100 m (minimum), between the two posts fitted and fixed with G.I. staples, turn buckles etc. complete. (Cost of posts, struts, earth work and concrete work to be paid for separately). Payment to be made per metre cost of total length of barbed wire used.With G.I. barbed wire Square meter 1500 Meter 177
56 Providing and filling in position rubberized bitumen hot sealing compound for sealing of expansion joints in roads / pavements all complete as per direction of the Engineer-in-Charge.Providing and filling in position rubberized bitumen hot sealing compound for sealing of expansion joints in roads / pavements all complete as per direction of the Engineer-in-Charge. Square meter 8700 Activity unit 300
57 Providing and laying 60mm thick faciory made cement concrete interlocking paver block of M -30 grade made by block making machine with strong vibratory compaction, of approved size, design & shape, laid in required colour and pattern over and including 50mm thick compacted bed of coarse sand, filling the joints with line sand etc. all complete as per the direction of Engineer-in-charge. Square meter 100 Square meter 77
58 Providing and fixing G.I. chain link fabric fencing of required width in mesh size 50x50 mm including strengthening with 2 mm dia wire or nuts, bolts and washers as required complete as per the direction of Engineer-in-charge. Made of G.I. wire of dia 4 mm Square meter 550 Square meter 37
59 Providing and laying C.C. pavement of mix M-25 with ready mixed concrete from batching plant. The ready mixed concrete shall be laid and finished with screed board vibrator , vacuum dewatering process and finally finished by floating, brooming with wire brush etc. complete as per specifications and directions of Engineer-in-charge. (The panel shuttering work shall be paid for separately). Deduct for using of M-20 grade concrete instead of M-25 grade concrete in C.C. pavement. Meter 350 Cubic meter 12
60 Construction of granular sub-base by providing close graded Material conforming to specifications, mixing in a mechanical mix plant at OMC, carriage of mixed material by tippers to work site, for all leads & lifts, spreading in uniform layers of specified thickness with motor grader on prepared surface and compacting with vibratory power roller to achieve the desired density, complete as per specifications and directions of Engineer-in-Charge. With material conforming to Grade-I (size range 75 mm to 0.075 mm) having CBR Value-30 Meter 500 Cubic meter 105
61 Providing and fixing water closet squatting pan (Indian type W.C. pan ) with 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required: White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests Square meter 2 each 13170
62 Providing and fixing white vitreous china pedestal type water closet (European type) with seat and lid, 10 litre low level white vitreous china flushing cistern & C.P. flush bend with fittings & C.I. brackets, 40 mm flush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required : W.C. pan with ISI marked black solid plastic seat and lid Square meter 2 each 750
63 Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: White Vitreous China Wash basin size 630x450 mm with a pair of 15 mm C.P. brass pillar taps Square meter 5 each 1315
64 Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS:13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required : Kitchen sink with drain board 510x1040 mm bowl depth 250 mm Square meter 2 each 1742
65 Providing and fixing controlled flush, low level cistern made of vitreous china with all fittings complete. 10 litre (full flush) capacity-white Square meter 2 each 75
66 Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete. Flexible pipe 32 mm dia Square meter 5 each 2800
67 Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete. Square meter 2 each 8320
68 Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour. 600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88 mm, weighing not less than 190 gms. Square meter 2 each 2007
69 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. Internal work - Exposed on wall 15 mm nominal dia Pipes Square meter 100 Meter 10220
70 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. Internal work - Exposed on wall 20 mm nominal dia Pipes Cubic meter 50 Meter 58
71 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. Internal work - Exposed on wall 25 mm nominal dia Pipes Cubic meter 100 Meter 71
72 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. Internal work - Exposed on wall 32 mm nominal dia Pipes Square meter 50 Meter 1311
73 Providing and fixing G.I. pipes complete with G.I. fittings including trenching and refilling etc. External work 15 mm dia nominal bore litre 75 Meter 164
74 Providing and fixing G.I. pipes complete with G.I. fittings including trenching and refilling etc. External work 20 mm dia nominal bore RM 75 Meter 755
75 Providing and fixing G.I. pipes complete with G.I. fittings including trenching and refilling etc. External work 25 mm dia nominal bore Kg 100 Meter 1550
76 Providing and fixing G.I. pipes complete with G.I. fittings including trenching and refilling etc. External work 40 mm dia nominal bore Square meter 50 Meter 198
77 Providing and fixing G.I. pipes complete with G.I. fittings including trenching and refilling etc. External work 50 mm dia nominal bore Cubic meter 100 Meter 196.2
78 Providing and fixing G.I. pipes complete with G.I. fittings including trenching and refilling etc. External work 65 mm dia nominal bore Cubic meter 50 Meter 230
79 Providing and fixing G.I. pipes complete with G.I. fittings including trenching and refilling etc. External work 80 mm dia nominal bore Square meter 50 Meter 965
80 Making connection of G.I. distribution branch with G.I. main of following sizes by providing and fixing tee, including cutting and threading the pipe etc. complete : 25 to 40 mm nominal bore each 15 each 6
81 Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) : 25 mm nominal bore each 5 each 3
82 Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) : 20 mm nominal bore each 5 each 9
83 Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) : 40 mm nominal bore each 5 each 5
84 Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) : 50 mm nominal bore each 5 each 2
85 Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) : 65 mm nominal bore each 5 each 3
86 Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete : 15 mm nominal bore each 10 each 6
87 Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete : 20 mm nominal bore each 5 each 9
88 Providing and fixing uplasticised PVC connection pipe with brass unions : 45 cm length 15 mm nominal bore Meter 10 each 50
89 Providing and fixing C.P. brass shower rose with 15 or 20 mm inlet : 150 mm diameter Meter 2 each 24
90 Providing and fixing to filter and lowering to proper levels 40 mm G.I. pipe for tube well including cleaning and priming the tube well. Meter 50 Meter 90
91 Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. Meter 12000 Liter 90
92 Providing and fixing C.P. brass bib cock of approved quality conforming to IS:8931 : 15 mm nominal bore Meter 20 each 10
93 Providing and fixing C.P. brass long nose bib cock of approved quality conforming to IS standards and weighing not less than 810 gms. 15 mm nominal bore Meter 5 each 45
94 Providing and fixing C.P. brass long body bib cock of approved quality conforming to IS standards and weighing not less than 690 gms. 15 mm nominal bore Meter 5 each 95
95 Supplying and fixing C.I. cover without frame for manholes : 455x610 mm rectangular C.I. cover (light duty) the weight of the cover to be not less than 23 kg Meter 5 Each 15
96 Providing and laying Non Pressure NP-3 class (Medium duty) R.C.C. pipes including collars/spigot jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete 450 mm dia RCC pipes. each 25 Meter 11
97 Providing and laying Non Pressure NP-3 class (Medium duty) R.C.C. pipes including collars/spigot jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete 600 mm dia RCC pipes. each 25 Meter 4
98 Providing and laying Non Pressure NP-3 class (Medium duty) R.C.C. pipes including collars/spigot jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete 900 mm dia RCC pipes. each 10 Meter 1
99 Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) : For fixed portion Powder coated aluminium (minimum thickness of powder coating 50 micron) each 500 Kilogram 2
100 Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) : For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately) Powder coated aluminium (minimum thickness of powder coating 50 micron) each 450 Kilogram 8
101 Providing and fixing 12 mm thick prelaminated particle board flat pressed three layer or graded wood particle board conforming to IS: 12823 Grade l Type ll, in panelling fixed in aluminum doors, windows shutters and partition frames with C.P. brass / stainless steel screws etc. complete as per architectural drawings and directions of engineer-in-charge. Pre-laminated particle board with decorative lamination on one side and balancing lamination on other side Liter 25 Square meter 12300
102 Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item): With float glass panes of 4.0 mm thickness (weight not less than 10kg/sqm) each 75 Square meter 22
103 Providing and fixing double action hydraulic floor spring of approved brand and manufacture conforming to IS : 6315, having brand logo embossed on the body / plate with double spring mechanism and door weight upto 125 kg, for doors, including cost of cutting floors, embedding in floors as required and making good the same matching to the existing floor finishing and cover plates with brass pivot and single piece M.S. sheet outer box with slide plate etc. complete as per the direction of Engineer-in-charge. With stainless steel cover plate minimum 1.25 mm thickness each 10 Each 7
104 Boring/drilling bore well of required dia for casing/ strainer pipe, by suitable method prescribed in IS: 2800 (part I), including collecting samples from different strata, preparing and submitting strata chart/ bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of Engineer-in-charge, upto 90 metre depth below ground level. All types of soil 300 mm dia each 90 Meter 5
105 Boring/drilling bore well of required dia for casing/ strainer pipe, by suitable method prescribed in IS: 2800 (part I), including collecting samples from different strata, preparing and submitting strata chart/ bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of Engineer-in-charge, beyond 90 metre & upto 150 metre depth below ground level. All types of soil 300 mm dia each 30 Meter 24
106 Gravel packing in tubewell construction in accordance with IS: 4097, including providing gravel fine/ medium/ coarse, in required grading & sizes as per actual requirement, all complete as per direction of Engineer-in-charge. each 25 Cubic meter 10
107 Supplying, assembling, lowering and fixing in vertical position in bore well, ERW (Electric Resistance Welded) FE 410 mild steel screwed and socketed/plain ended casing pipes of required dia, conforming to IS: 4270, of reputed & approved make, including painted with outside surface with two coats of anticorrosive paint of approved brand and manufacture, including required hire & labour charges, fittings & accessories, all complete, for all depths, as per direction of Engineer-in-charge. 100 mm nominal size dia having minimum wall thickness 5.00 mm Meter 40 Meter 50
108 Supplying, assembling, lowering and fixing in vertical position in bore well, ERW (Electric Resistance Welded) FE 410 mild steel screwed and socketed/plain ended casing pipes of required dia, conforming to IS: 4270, of reputed & approved make, including painted with outside surface with two coats of anticorrosive paint of approved brand and manufacture, including required hire & labour charges, fittings & accessories, all complete, for all depths, as per direction of Engineer-in-charge. 150 mm nominal size dia having minimum wall thickness 5.00 mm Meter 50 Meter 40
109 Supplying, assembling, lowering and fixing in vertical position in bore well, ERW (Electric Resistance Welded) FE 410 plain slotted (having slot of size 1.6/3.2 mm) mild steel threaded and socketed/ plain bevel ended pipe (type A) of required dia, conforming to IS: 8110, of reputed and approved make, having wall thickness not less than 5.40 mm, including painted with outside surface with two coats of anticorrosive bitumestic paint of approved brand and manufacture, including hire & labour charges, fittings & accessories, all complete, for all depths, as per direction of Engineer -in-charge. 100 mm nominal size dia Meter 30 Meter 5656
110 Development of tube well in accordance with IS : 2800 (part I) and IS: 11189, to establish maximum rate of usable water yield without sand content (beyond permissible limit), with required capacity air compressor, running the compressor for required time till well is fully developed, measuring yield of well by "V" notch method or any other approved method, measuring static level & draw down etc. by step draw down method, collecting water samples & getting tested in approved laboratory, i/c disinfection of tubewell, all complete, including hire & labour charges of air compressor, tools & accessories etc., all as per requirement and direction of Engineer-in-charge. Meter 25 Hour 697.8
111 Providing and fixing suitable size threaded mild steel cap or spot welded plate to the top of bore well housing/ casing pipe, removable as per requirement, all complete for borewell of: 150 mm dia each 2 Each 1208
112 Providing and fixing M.S. clamp of required dia to the top of casing/ housing pipe of tubewell as per IS: 2800 (part I), including necessary bolts & nuts of required size complete. 150 mm clamp each 2 Each 124
113 Providing and fixing Bail plug/ Bottom plug of required dia to the bottom of pipe assembly of tubewell as per IS:2800 (part I). 100 mm dia Kilogram 1 Each 250
114 Arranging and spreding 75 mm thick broken grit 20 mm (Granite stone) uniform for turfing over 100mm thick base course of C.C. In 1:4:8 (1cement:4coarse sand: 8, 40mm stone ballast) top finish by brooming of cement mortar 1:4(1cement: 4 Coarse sand) including supply of all materials, labour and tools and plants etc. required for proper completion. Kilogram 14000 Square meter 400
115 Supply and filling brick bat in soak pit including all labour,material and T&P etc complete. (for 01 soak pit) Square meter 5 Cubic meter 20
116 Supply of 28 mm. dia M.S. Anchor bolts (conforming to IS 266) 900 mm. long with base plate (75x75x6mm) welded with anchor bolts including its threading upto a length of 10cm. and also supply of a pair of galvanized standard nuts with threading including supply of 5 mm thick washer and cost of labour, material & T&P for proper completion of work Square meter 1200 Number 90
117 Fixing and grouting 28 mm and above dia bolts in proper alignment level and setout with help of a template complete including supply of all labour & T&P etc. required for proper completion of the work.(labour rates only) . Each 1200 Number 6
118 Supply of 25 mm dia.M.S. Anchor bolts (conforming to IS-226) 500 mm long with base plate(50x50x6 mm)welded with anchor bolts,including its threading upto a length of 10cm. and galvanizing upto 15cm from top, also supply of a pair of galvanized standard nuts with threading including supply of 5mm thick washer and cost of labour material and T&P etc. required for proper completion of the work. Meter Number 90
119 Fixing and grouting 25 mm and below dia M.S. Anchor bolt in proper alignment level and setout with the help of a template including supply of all labour T&P etc. reqd. for proper completion of the work. (labour rates only) . Each Number 80
120 S/F in position 90 lbs M.S. Rail for transformer plinth including cost of all labour, material and T&P etc. required for proper completion of the work. Meter 20 Meter 90
121 Grouting of vertical or inclined post of pale/chain/security fencing in true level, alignment and in plumb or inclination as required, including cost of all labour, materials and T&P required for proper completion of work. ( Post and concrete for grouting shall be measured separately) Meter 120 Number 30
122 Fixing and grouting of trench edging in proper level and alignment including cost of all labour, and T&P etc. required for proper completion of the work but excluding cost of C.C. (labour rates only) . Meter 2600 Meter 90
123 Fixing of template in position level and alignment for grouting of Anchor bolt in main gantry (labour rate only). Meter 60 Number 30
124 Same in NSI item-23 above but for auxiliary structure. (labour rate only). Cubic meter 232 Number 15
125 Fixing of cable trench racks in proper position and alignment including cost of all labour, material and T&Petc. required for proper completion of the work (Labour rate only). Hour 5000 Number 25
126 Providing (12x15) mm section groove in plaster including all material, labour and T&P etc. required for proper completion of the work. Square meter 1200 Meter 200
127 Champering the edge of concrete in auxiliary structure, of size 25 mm wide in triangular section including all materials, labour & T&P etc complete. Square meter 5500 Meter 120
128 2.5 cm thick 1:1.5:3 plain cement concrete floor with cement, approved coarse sand & 2cm graded approved stone ballast laid in panels finished with 3mm floating coat of neat cement or cement and marble dust in ratio of 5:1 as specified and removing any overlapping mortar at the joints of the panels if any and giving them a uniform finish including supply of all materials, labour and T&P etc, required for proper completion of the work. without base CC Cubic meter 850 Square meter 5
129 As in NSI item No.-35 above but 4.0 cm thick floor in 1:1.5:3 concrete with out base concrete. Square meter 350 Square meter 200
130 Painting letters & number over cable trench cover or other places with the help of stencils including painting of base of 150 mm. dia of one coat of primer and two coats of superior quality synthetic enamel paint size of letter to be 60 mm. x 10 mm. including cost of all materials labour and T&P etc. required for proper completion of the work including placing of Trench covers in required position Cubic meter 2200 Number 5
131 Pre-Construction anti-termite treatment, by creating a barrier under and around the columns pits, foundation trenches, under floors, junctions of Walls & floors, around the external perimetre of building, expansion joints, surrounding of pipes and conduits etc. (Plinth area of the building at ground floor only shall be measured as per I.S. 6313 (Part II 1981))with Eldrine emulsifiable 0.2% concentration or any other approved material such as Heptachlore or chlordance will be used. The consumption of emulsion shall be (i) Foundation and masonary @ 5 Ltrs/Sqm, (ii) Back fills in immediate contact of foundation@ 7.5 Ltrs. / Sqm, (iii) Top surface of Plinth filling @ 5 Ltrs / Sqm, ( iv) Junction of walls & floors @ 7.5 Ltrs / Sqm, (v) Soil along external perimetre of building @ 7.5 Ltrs / Sqm (vi) under apron of the building @ 5 Ltrs. /Sqm. The rates includes cost of all materials, labour, equipments, T&P complete. each 400 Square meter 20
132 Supply and fixing support clamps for column pipes made out of MS flats, pairs of bolt-nuts etc complete with all material, labour, T&P. 40 mm dia. each 1 Number 100
133 Transportation and installation of tube well drilling Rig m/c, compressure for development and other required equipments and accessories at site of work and dismentlling & taking them back after successful completion of the work including cleaning, levelling - dressing the site properly, also disposing off the surplus earth, silt, sand etc. each 1 Job 75
134 Supply and installation of 5H.P. Kirloskar or equivalent make single stage, horizontal, self priming,three phase dewatering pumpset of specification Head 14/16 M, Discharge 13.6/10 LPS, solid handle size 15.5 mm, suction 80 mm, delivery 80 mm, RPM 1500 including cost of 80 mm dia G.I. pipe for suction (3M) and delivery (4.5 M). each 1 Number 50
135 Supply & installation of electrical control panel of L&T / Havells or equivalent make for submersible pump / pumpset containing contractor relay condenser. b) for 1.5/ 2 H.P pump set single phase each 1 Number 75
136 Supply & installation of electrical control panel of L&T / Havells or equivalent make for submersible pump / pumpset containing contractor relay condenser. d) for 5 H.P pump set three phase each 1 Number 25
137 Supply & Installation of submersible pump of K.S.B/ CALAMA. or eqt. make including cost of labour, T&P and material required for completion of work. d) 3 HP outlet 50 mm dia. or more, Head 60/24, Discharge 6000/14000 LPH each 1 Number 75
138 Supply & fixing of steel wire rope for submersible pump including cost of labour, T&P and material required for completion of work. each 90 Meter 50
139 Placing of trench cover of all size in proper position including transportation from different places within the S/S area including all labour, T&P etc. required for proper completion of the work as per direction of Engineer - in - charge. Points 2200 Number 145
140 Providing and fixing soap dish chromium plated with brackets fixed to wooden cleats with brass screws including supply of all materials,labour and T&P etc.required for proper completion of the work. Meter 2 Number 109
141 Providing and laying SWR, PVC ( Finolex or equivalent ) pipe including cost of excavation, C.C etc including its jointing and connection, all materials, labour and T&P etc. required for proper completion of the work. c) 110 mm Dia. Meter 50 Meter 500
142 Providing and fixing SWR, PVC ( Finolex or equivalent ) Bends including cost of all materials, labour and T&P etc required for proper completion of the work. 110 mm dia Meter 10 Number 185
143 S/F full way 63/65 mm dia Fire hydrant Gun Metal Gate Valve heavy quality including supply of all labour , material andT & P for proper completion of work Meter 2 Number 185
144 P/F Male & Female coupling 63/65 mm dia. Gun metal BSI marked confirming to IS:903 heavy quality including supply of all labour , material and T & P for proper completion of work each 2 Number 75
145 P/F Short Branch pipe Gun Metal BSI marked heavy quality including supply of all labour , material and T & P for proper completion of work. each 2 Number 10
146 P/F 63 mm dia RLL Hose Pipe heavy quality having length 15.0 m including supply of all labour , material andT & P for proper completion of work. each 30 Meter 10
147 P/F MS Hose Box Single Door with stand for 15 mt RRL Hose heavy quality including supply of all labour , material andT & P for proper completion of work. each 2 Number 15
148 Placing of 10 KL PVC Tank over slab of 6 m staging including supply of all labour , material andT & P for proper completion of work. each 1 Job 7
149 Contouring of sub-station with help of leveling instrument/ total station instrument & staff including plotting of trees and structure if any including preparation of contour plan in 6 copies including marking periphery including all labour, Supervisor, instrument, T&P materials complete as per direction of Engineer I/C. each 20000 Square meter 10
150 Marking of building and foundation in new sub-station (132/220 KV) in UPPCL land as per approved layout drawing with help of Theodolite/ total station instrument and closing of Travers for main Gantry etc including cost of all labour, Supervisor, instrument, T&P materials complete as per direction of Engineer I/C. each 1 Job 10
151 Making borehole in all type of soil by any method required as per site conditions in accordance with IS specification No 1982-1979 and 1498-1970 and conducting standard penetration test in accordance with IS specification No 2131 – 1981 at every 1.5 M approx . or as per strata during making borehole and also collecting undisturbed and disturbed soil samples at a depth of approx. 1.5 M depth or change of strata of soil as per site requirements in each borehole in accordance with IS specification 1892-1978. (Depth of water table as detemine from borehole or from nearest waterwell ) Each Boreholes to be bored upto 15.00 depth. each 75 Meter 3
152 Undisturbed soil samples collected in field will be tested in Laboratory and preparation of samples for tests mentioned below, will be done/governed in accordance with IS 2720 (Part 1)-1983 i)Tri axial compression test and determination of shear parameters(c&) as per ISS –2720 (Part ix) ISS 2720-(Part xii) ISS 2720-(Part xiii) on silty/sandy soil . Consolidation Test as per ISS-2720( Part xv )on clay soil ii)Sieve analysis test as per ISS 2720 (Part iv) iii) Atterberg’s limit tests as per ISS –2720 (Part v) iv)Particle size analysis test as per ISS 2720 (Part iv) v)Natural moisture content test as per ISS 2720 (Part vi) vi)Wet density test and dry density test as per ISS 2720 (Part vi) vii)Specific gravity test as per ISS 2720 (Part iii) section 2 Disturbed soil samples will be prepared in accordance with ISS 2720 (Part I) 1983 and tested as follows i)Sieve analysis test as per ISS – 2720 (part iv) ii)Atterberg’s limit tests as per ISS- 2720(Part v) each 1 Job 32
153 Conducting plate load test near CONTROL ROOM BUILDING site at specifed depth as per IS 1980-1982 including supply of all material, labour and T&P equipment and recording of test result as per Codal requirement and submission of report. each 1 Job 2
155 Supply and Fixing of 3 blade wall fan of Havells platina 400 mm or equivalent including all material, T&P etc required for proper completion of work as approved by engineer in charge. Meter 10 each 1
156 Supply and Fixing of 5 blade Exhaust fan ventile air dx 225 mm of Havells or equivalent make including all material, T&P etc required for proper completion of work as approved by engineer in charge. Set 5 each 1
157 Supply and fixing of 36 Watt to 46 Watt indoor Recess mounting LED Square Fitting for Armstrong Ceiling having Powder coated die cast aluminium housing body with extended heat sink and diffuser of Special Polycarbonate meterial and driver set complete in all respect. Square meter 35 each 4500
158 Supply and fixing of LED Tube Light batten fitting suitable for up to 1 X 22 watt LED tube light on surface complete in all respect. Cubic meter 50 each 22
Horticulture Item Number 1640
159 Supplying and stacking of good earth at site including royalty and carriage upto 5 km lead complete (earth measured in stacks will be reduced by 20% for payment). Number 5 Cubic meter 1640
160 Supplying and stacking sludge at site including royalty and carriage upto 5 km lead complete (sludge measured in stacks will be reduced by 8% for payment). Number 10 Cubic meter 1832
161 Supplying and stacking at site dump manure from approved source, including carriage upto 5 km lead complete (manure measured in stacks will be reduced by 8% for payment) : Screened through sieve of I.S. designation 20 mm Number 5 Cubic meter 1948
162 Mixing earth and sludge or manure in the required proportion specified or directed by the Officer-in-charge Meter 10 Cubic meter 20
163 Providing & laying Selection no. 1 doob grass turf with earth 50mm to 60mm thickness of existing ground prepared with proper level and ramming with required tools wooden and than rolling the surface with light roller make the surface smoothen and light watering the same maintenance for 30 days or more till the grass establish properly,as per direction of officer in charge Number 200 Square meter 75
164 Plantation of Trees, Shrubs, and Hedge at site i/c watering and removal of unserveiceable material's as per direction of officer in charge (excluding cast of plant & water) Hedge Plant/Ground cover Meter 200 each 2483
165 Providing and Displaying Dahlia double kenya variety in different colour well developed with 3 to 4 flowers in half bloom, good foliage stacked with Green painted Bamboo sticks, 45 to 60 cm height in 25 cm Earthen Pot/ Plastic Pot and as per direction of the officer-in-charge. Number 200 each 83
166 Providing and Displaying Marigold jaffri dwarf in different colour well developed with fresh & healthy foliage with 12 to 15 flowers in full bloom specimen plant 23 to 30 cm ht. in 20 cm Earthen Pot/Plastic Pot and as per direction of the officer-in-charge. Number 200 each 312
167 Providing and Displaying Marigold jaffri orange/yellow/Russet colour well developed with fresh & healthy foliage with 40 to 50 flowers in bloom specimen plant 60 to 75 cm ht in 25 cm Earthen Pot/Plastic Pot and as perdirection ofthe officer-in-charge. Number 60 each 5295
168 Providing and stacking of plant Mogra of height 25 to 30 cm., 2 to 3 branch in earthen pots of size 20 cm Earthen Pot/Plastic Pot and as per direction of the officer-in-charge. Meter 90 each 5725
169 Providing and Displaying Standard Rose (H.T. variety) 3 to 4 healthy branch 90 cm and above ht. well developed with one and above flowers in 25 cm Earthen Pot, as per direction of the officer-in-charge. Meter 90 each 5289
170 Providing and stacking of Polyalthia pendula (Ashok Pendula) of height 150-165 cm. in earthen pots of size 25 cm as per direction of the officer-in-charge. Number 150 each 2543
171 Providing and stacking of Polyalthia pendula (Ashok Pendula) of height 180-195 cm. in gunny bag of size 30 cm as per direction of the officer-in-charge. Square meter 50 each 540
Electricle Item Number 1
172 Supplying and drawing following 3 x 2.5 sq. mm sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. Number 100 Meter 1
173 Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required..Group C Number 120 Points 2
174 Supplying and fixing of 20 mm of medium class PVC conduit along with accessories in surface/recess including junction box, cutting the wall and making good the same in case of recessed conduit as required. RM 250 Meter 50
175 Supplying and fixing of 25 mm of medium class PVC conduit along with accessories in surface/recess including junction box,cutting the wall and making good the same in case of recessed conduit as required. 25 mm Job 750 Meter 1
176 Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire Number 450 Meter 1
177 Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required 2 X 4 sq. mm + 1 X 4 sq. mm earth wire Number 300 Meter 2
178 Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required 2 X 6 sq. mm + 1 X 6 sq. mm earth wire Number 170 Meter 1
179 Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required. Meter 1 Set 100
180 Providing and laying earth connection from earth electrode with 6 SWG dia G.I. Wire in 15 mm dia G.I. pipe from earth electrode including connection with G.I. thimble excavation and re-filling as required. Number 20 Meter 2543
181 Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single pole NOT FOUND 30 each 3
182 Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.63 amps Meter 5 each 20
183 Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 4 way (4 + 12), Double door NOT FOUND 2 each 8
184 Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 volts, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 amps tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCB's (but without MCB's and incomer ) as required . (Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required.) 4 way (4 + 12), Double door Number 2 each 8
185 Supplying and fixing following size/ modules, GI box along with modular base & cover plate for modular switches in recess etc as required. 1 or 2 Module (75mmX75mm) Meter 10 each 70
186 Supplying and fixing following size/ modules, GI box along with modular base & cover plate for modular switches in recess etc as required. 3 Module (100mmX75mm) Number 15 each 8
187 Supplying and fixing following size/ modules, GI box along with modular base & cover plate for modular switches in recess etc as required. 4 Module (125mmX75mm) Number 10 each 12
188 Supplying and fixing following size/ modules, GI box along with modular base & cover plate for modular switches in recess etc as required. 6 Module (200mmX75mm) Number 15 each 12
189 Supplying and fixing following size/ modules, GI box along with modular base & cover plate for modular switches in recess etc as required. 8 Module (125mmX125mm) Number 20 each 9
190 Supplying and fixing following size/ modules, GI box along with modular base & cover plate for modular switches in recess etc as required. 12 Module (200mmX150mm) Number 20 each 5
Furniture Number 5
191 Supply of Executive office table size W2400 X D2100 X H750 PLPB Top, Extruded aluminium profile Geeken or equivalent make as approved by E/I. (Model No. EWOKE 1) Number 1 No 5
192 Supply of Executive office table size W2000 X D1850 X H750 Particle board top Geeken or equivalent make as approved by E/I. (Model No. EXCLUSIVE 2) Meter 1 No 120
193 Supply of Back Storage unit size W2250 X D450 X H2200 18 mm PLPB, PVC Edge Banded Tape Geeken or equivalent make as approved by E/I. (Model No. EWOKE 4) Number 2 No 5
194 Supply of Back Storage unit size W750 X D450 X H2200 18 mm PLPB, PVC Edge Banded Tape Geeken or equivalent make as approved by E/I. (Model No. EWOKE 4) Job 2 No 1
195 Supply & Fixing of High back Revolving chair PP Cushion arm ,Gas lift Leatherite Tapestry Geeken or Equvalent make as approved by E/I (Model No. ALTONA 1) Job 2 No 2
196 Supply & Fixing of chair with PP seat back and Powder Coated Metal Frame, Geeken or Equvalent make as approved by E/I.(Model No. GB 403) each 10 No 12
197 Supply of steel almirah size W900 X D450 X H1830 Geeken or equivalent make as approved by E/I. (Model No. GMS 10) each 2 No 5
198 Supply and fixing of blind stripe roller dim out Kazage make or equivalent with Haid rail and all material, T&P and labour required for proper completion of job as per direction & approved by Engineer-In-Charge. (NSI) each 180 Sqm. 5
Seal of Company Full Signature …………………………
Designation ……………
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.45 MB
TS.pdf
Tender Documents • 5.46 MB
BOQESD-681.xls
Additional Documents • 1.06 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at [email protected].