Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹6.0 CrAccepted-AOC | ₹6.0 Cr | L1 | Accepted-AOC Being Lowest Bidder |
| 2 | L2₹6.2 Cr+₹18.5 L (3.08%)Rejected-Finance C 709 VARDHAMAN APARTMENT MAYUR VIHAR I DELHI 110091 INDIA | EAST | DELHI | 110091 | ₹6.2 Cr+₹18.5 L (3.08%) | L2 | Rejected-Finance Being 2nd lowest |
| 3 | Rejected-Technical | - | - | Rejected-Technical Not carried out similar work in last 07 years |
| 4 | Rejected-Technical 401 THE GRAND MALL OPP STATE BANK ZONAL OFFICE S M ROAD AMBAWADI AHMEDABAD 380015 | AHMADABAD | GUJARAT | 380015 | - | - | Rejected-Technical Not enlisted in b(ii) cat |
| 5 | Rejected-Technical BINDA JAYANTI BUILDING 31 SEVOKE ROAD SILIGURI PIN 734001 DIST DARJEELING | SILIGURI | DARJEELING | WEST BENGAL | 734001 | - | - | Rejected-Technical Not carried out similar work in last 07 years and not enlisted in b(ii) cat |
Tender Value
₹8.7 Cr
EMD Value
₹7.6 L
Closing Date
1 May 2020, 6:00 pmClosed
CE (AF) SHILLONG ZONE
HQ CE (AF) SHILLONG ZONE, ELEPHANT FALLS CAMP, PO-NONGLYER, SHILLONG-793009
PROVISION OF WORK SERVICES FOR REMOVAL AND REINSTALLATION OF RUNWAY LIGHTS AT AF STN HASIMARA
2020_MES_329835_1
88422/HAS/E8
Open Tender
Miscellaneous Works
Item Rate
180 days
GE P AF Hasimara
As per tender documents
7 documents required · 7 mandatory
₹3,000
GE (P) (AF) HASIMARA
₹7.6 L
Yes
19 May 2020
29 Feb 2020
7 May 2020
29 Feb 2020
1 May 2020
20 Mar 2020
29 Feb 2020 - 19 Mar 2020
Amount
Material and labour for Taking out/ Dismantling of existing Runway Inset light fitting and Runway Elevated fitting any type, Taxi way light, Stop bar lights, CI Box, Isolating Transformer, Sign boards, PAPI Units etc with base including core cutting disconnecting all electric wiring including transport from the runway site upto store for safe handing in the Air Force Auth, GPS survey making (X,Y,Z coordinates) coring by core cutting equipment on rigid/flexible pavement upto cutting circular hole of dia 326mm and depth of 150mm or as required for fixing of existing fitting in PQC rigid/ flexible pavement of runway or as per requirement for fixing of light fitting and precise alignment for following items all as specified and directed:-
Runway adge C/C, C/Y, overrun & stop way elevated lights
Top assembly for inset runway edge lights
Turning pad lights elevated
Top assembly of runway center line lights
Top assembly of TDZ lights
Top assembly of inset threshold, threshold cum end lights
Elevated elvated wing bar lights
Top assembly of stop bar lights
Elevated taxi way dispersal edge lights
Removal of PAPI units
CAT II simple and side row approach elevated lights
Top assembly for inset approach lights and side row inset lights
Removal of 12 inch shallow base for runway edge, threshold, taxiway edge, approach, siderow approach & simple approach using suitable core cutting
Removal of 8 inch shallow base for runway centre line TDZ & stopbar lights using suitable core cutting
200 W IT for runway edge stopway & dispersal other lights
100 W for runway centre line lights
45w for taxiway, turning pad and dispersal edge lights
300 w for threshold side row and approach lights
TH box for runway edge and stop bar lights
TH box for runway centre line lights
TH box for TDZ lights
TH box for threshold & wingbar
TH box for approach lights, simple approach, supplimentry approach
TH box for PAPI and taxiway lights
TH box for turning pad and stopbar lights
TH box for crossing all circuit
Removal of sign boards
Removal of DTGM
Primary cable from the ducts
Material and labour for Re-installation, testing and commissioning of Runway Inset light fitting and Runway Elevated fitting any type, Taxi way light, Stop bar lights, CI Box, Isolating Transformer, Sign boards, PAPI Units etc with base at new raised surface of runway including transport from the store upto upto runway site, GPS survey making (X,Y,Z coordinates) and submission of completion drawing, to its existing position including compaction and ramming the surface and making good the existing surface with adequate material to match the existing surface coring by core cutting equipment on rigid/flexible pavement upto cutting circular hole of dia 326mm and depth of 150mm or as required fixing of existing fitting in PQC rigid/ flexible pavement of runway or as per requirement for fixing of light fitting and precise alignment for following items all as specified and directed:- Note:- The dismantelled items shall be handed over to the users and AGE (E/M) shall re-issue the reusable items for exection at site.
Runway edge light bi-directional elevated (C/C)
Runway edge light bi-directional elevated (C/Y)
Runway edge unit directional light elevated (B/R)
Runway edge lights inset C/Y (2 x 105 W) including shallow base
Stop way light elevated - APN952
Turning pad light elevated blue
Sand blasting and repainting of shallow base
O ring gasket for shallow base
Threshold green bi-dircetion inset (toe in left)
Threshold green bi-dircetion inset (toe in right)
Threshold bi- direction green/red inset (toe in left)
Threshold bi-direction green/red inset (toe in right)
Sand blasting and repainting of shallow base
O ring gasket for shallow base
Runway centre line lights insets (C/C)
Runway centre line lights insets (C/R)
Sand blasting and repainting of shallow base
O ring gasket for shallow base
Approach light white undirectional inset
Approach light white undirectional elevated
Sand blasting and repainting of shallow base
O ring gasket for shallow base
Supplimentary approach inset
Sand blasting and repainting of shallow base
O ring gasket for shallow base
Touch down zone light inset
Sand blasting and repainting of shallow base
O ring gasket for shallow base
Stop bar light inset
Sand blasting and repainting of shallow base
O ring gasket for shallow base
Approach light white inset (simple)
Sand blasting and repainting of shallow base
O ring gasket for shallow base
Taxiway light fitting blue elevated
Precision approach path indicator (PAPI)
Design siting of PAPI system and ground calibration of PAPI system
Installation of sign boards
Installation of DTGM
Connector kit for 1 core x 6 sqn m cable
Isolation transformer - 200 W - 6.6 A/6.6A
Isolation transformer - 45 W - 6.6 A/6.6A
Isolation transformer - 300 W - 6.6 A/6.6A
Isolation transformer - 100 W - 6.6 A/6.6A
Excavation for laying multiple conduits of 600 mm width in soft soil for depth upto 650 mm including getting out the excavated soil and refilling the trench with excavated
Increase of height for manholes/ new manhole
Installation of Transformer Housing Box
Installation of elevated Runway/ Taxiway edge lights using anchor fasteners
Installation of precast transformer Housing Box
Gasket for elevated runway & Taxiway edge lights
Dummy plate with gasket and necessary M10 bolts
Survey aligning the RW centre line making of location of all insert lights on ranway with surveor
End cap for 40 mm conduit
End cap for 25 mm conduit
Pulling Rope
Supply, installation, testing and commissioning of Runway edge High Intensity Bi-directional Insert light C/Y, with (2x105w) halogen lamp with 12" inch shallow base complete with bottom box and all accessories including halogen lamp, lens/ red filter, reflector etc. as required and as specified.
Supply, installation, testing and commissioning approach Intensity Uni-directional Insert Light White, with (3x105w) halogen lamp with 12" inch shallow base complete with bottom box and all accessories including halogen lamp, lens/ red filter, reflector etc. as required and as specified.
Supply, installation, testing and commissioning elevated type omni directional taxiway/apron/turning pad light fixtures suitable for 36 W halogen Lamp type on 6.6 A AC constant current series system complete with blue lense, connecting lead, breakable coupling, base plate and all other accessories etc. as required and as specified.
Supply and installation of DTGM
Material and labour for earthing pit
Supply and fixing of earthing 8 SWG GI wire complete all as directed.
Supply and fixing of connector kit for 1 core x 6 sqmm cable complete all as directed.
Supply, installation, testing and commissioning of 5000V, 50 Hz individual lamps series type isolating transformers encapsulated in polyester resin, finally moulded with neoprene rubber as specified in particular specifications of ratings 45W 6.6 A/6 6A.
Supply, installation, testing and commissioning of 5000V, 50 Hz individual lamps series type isolating transformers encapsulated in polyester resin, finally moulded with neoprene rubber as specified in particular specifications of ratings 200W 6.6 A/6. 6A
Supply, installation, testing and commissioning of 5000V, 50 Hz individual lamps series type isolating transformers encapsulated in polyester resin, finally moulded with neoprene rubber as specified in particular specifications of ratings 300W 6.6 A/6. 6A
Supply, installation, testing and commissioning Primary cables 1C x 6 Sqmm Airfield lightning (5KV) complete all as directed.
Supply, installation, testing and commissioning Secondary cables 1C x 4 sqmm (0.75 KV) complete all as directed.
Supply and fixing of 32 mm HDPE conduit for primary cables pulling complete all as directed.
Excavation for laying multiple conduits of 350 mm width in soft/ loose soil for depth upto 650 mm including getting out the excavated soil and refilling the trench with excavated soil complete all as directed.
Supply and fixing of C.I. Housing Box along with top lead, round type, metal container of size 330 mm dia and 450 mm height made of 10 mm thick cast iron moulding all around, except the top surface which is 15 mm thick suitable to receive a light fitting base plate on top, having clear holes (for AFL cable entry) center 3" above bottom surface suitable to receive 1 no 50 mm dia GI Pipe & check nut as required. The box should have two Earth Bolts of M-10 x 30 mm welded inside near the cable entry hole on one side and having a drain hole at the bottom suitable tapped to receive 15 mm dia GI Pipee and having clear opening of 220 mm at the top surface and 6 nos M 10 tapped hole at the ceter 260 mm dia to receive fitting base plate and bolts as required.
Supply and installation of elevated Runway/ Taxiway edge lights using anchor fasteners
Supply and installation of Gasket for elevated runway & Taxiway edge lights
Supply and fixing of dummy plate and necessary M-10 bolts as per size of housing box.
Supply and fixing 8 mm SWG GI wire complete all as dierected.
Material and labour for earth pits.
Supply and fixing of 40 mm dia HDPE conduit for primary cables pulling complete all as directed.
Supply and fixing of 150 mm shallow can and installation of elevated Runway edge lights on 150 mm shallow.
Supply of 40 mm inner dia GI conduit including accessories as T joint, end cap, elbow etc to lay in under kerf cutting area for running cable complete all as directed.
Supply of 25 mm inner dia GI conduit including accessories as T joint, end cap, elbow, etc to lay in undre kerf cutting area for running cable complete all as directed.
Material and labour for kerf cutting in existing asphalt surface of size 75 mm X 100 mm deep for laying 40 mm GI conduit including accessories required & filling with DBM complete all as directed.
Material and labour for kerf cutting in existing asphalt surface of size 60 mm X 100 mm deep for laying 25 mm GI conduit including accessories required & filling with DBM complete all as directed.
Material and labour for kerf cutting in existing concrete surface of size 75 mm X 100 mm deep for laying 40 mm GI conduit including accessories required & filling with concrete of M10 grade complete all as directed.
Material and labour for kerf cutting in existing concrete surface of size 60 mm X 100 mm deep for laying 25 mm GI conduit including accessories required & filling with concrete of M10 grade complete all as directed.
Integration with MAFI RCMS
REWINDER TECHNO ELECTRICALS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .