Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹7.0 LAccepted-AOC | L1 | Accepted-AOC Tender AoC | |
| 2 | L2₹7.8 L+₹26,647 (3.55%)Rejected-Finance | L2 | Rejected-Finance Being L2 | |
| 3 | L3₹8.3 L+₹78,170 (10.4%)Rejected-Finance H NO 29 DEVILAL COLONY TCP 2 HISAR CANTT HARYANA | HISAR | HISAR | HARYANA | 125006 | L3 | Rejected-Finance Being L3 | |
| 4 | L4₹8.7 L+₹1.2 L (16.1%)Rejected-Finance | L4 | Rejected-Finance Being L4 | |
| 5 | L5₹9.0 L+₹1.5 L (19.4%)Rejected-Finance | L5 | Rejected-Finance Being L5 |
Tender Value
₹15.3 L
EMD Value
₹31,000
Closing Date
7 Sept 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (WEST) HISAR
GE (WEST) HISAR HISAR MIL STN HISAR 125006
GE(W)/HSR-20/2022-23 REPAIR AND MAINTENANCE OF WINTER APPLIANCES AND CERTAIN MISC WORK AT HISAR MIL STN UNDER GE(WEST) HISAR
2022_MES_544541_1
GE(W)/HSR-20/2022-23 REPAIR AND MAINTENANCE OF WIN
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE (WEST) HISAR
As per tender documents
8 documents required · 8 mandatory
₹500
GE (WEST) HISAR
₹31,000
Yes
28 Oct 2022
10 Aug 2022
9 Sept 2022
10 Aug 2022
7 Sept 2022
25 Aug 2022
Amount
Attending of complaints pertaining to unsatisfactory/unfunctional state of solar water heater/ Geyser through telephone or in person on detailment at MES Service centre for Md/OTM accommodation in Hisar Mil Station incl EBS by rectification of fault of geysers / solar water heater points complete and carrying out repairs to the extent of disconnection and carefully taking down faulty wires, battens, conduits, boxes, main switches, MCBs, DBs heating elements thermostat and other E/M faults pertaining to particular instrument including wire upto 1.00 mtr and insulation tape required for the rectification of defect and refixing of existing dismantled serviceable articles and make good for functional serviceability after repair/replacement of fixtures complete. Cost of work requiring replacement of other stores will be measured as supply only and paid separately. Contracor shall provide the complaint slip containing 100 pages in duplicate (in two colour) of existing size properly binded and printed all as per sample and directed by Engr-in-Charge.
Supply only gun metal check valve / non return valve 15 mm dia suitable for Geyser of any make/capacity complete. All as specified and directed by Enge in charge.
Supply only pressure release valve for geyser 15 mm dia. All as specified and directed by Enge in charge.
Supply only geyser heating element 1500 watt suitable for any type, size & make of geyser. All as specified and directed by Enge in charge.
Supply only geyser heating element 2000 watt suitable for solar water heater of any type, size . All as specified and directed by Enge in charge.
Supply only thermostat of geyser suitable for any type, size & make of geyser.
Supply only PVC Cable of size 40/0.060mm 3 core copper conductor round type. All as specified and directed by Enge in charge.
Supply only indicating lamp round type suitable for Geyser. All as specified and directed by Enge in charge.
Supply only S/S heating plate assembly complete with water inlet & outlet, rubber gasket, nuts and bots and washers of required size suitable for 50 Ltr Capacity Geyser of any type and make etc complete. All as specified and directed by Enge in charge.
All as per Srl item No 9 above but suitable for capacity 25 Ltrs Geyser. All as specified and directed by Enge in charge.
Supply only glass wool for geyser vessel of any size and capacity complete. All as specified and directed by Enge in charge.
Supply only mild steel holding/anchor bolts and nuts machine made of size 10cm to 15cm long and dia of bolt 10mm to 15mm complete. All as specified and directed by Enge in charge.
Supply only dead nut/Safety plug of brass as per sample suitable for Geyser of any capacity/make. All as specified and directed by Enge in charge.
Supply only inner tank of geyser capacity 25 ltr made out of 16 SWG sheet Steel suitable for Geyser of any type and make to match the existing size and shape of inner tank of Geyser installed at site. All as specified and directed by Enge in charge.
All as per Srl item No 14 above but for Geyser of capacity 50 ltrs. All as specified and directed by Enge in charge.
Supply only outer tank of geyser made out of GI sheet of existing gauge, shape including top and bottom cover plate complete suitable for inner tank 25 ltr capacity geyser of any make complete. All as specified and directed by Enge in charge.
All as per item No 16 but suitable for 50 ltr capacity geyser. All as specified and directed by Enge in charge.
Supply only metal plug Socket 20 Amp (enclosure type) suitable for geyser. All as specified and directed by Enge in charge.
Supply only metal plug top 20A (enclosure type) suitable for geyser. All as specified and directed by Enge in charge.
Supply only hot water PVC connection of 15mm bore heavy duty, length upto 45cm with brass nut joints and washers at both ends complete. All as specified and directed by Enge in charge.
Supply only Cold water PVC connection of 15mm bore heavy duty, length upto 45cm with brass nut joints and washers at both ends complete. All as specified and directed by Enge in charge.
Supply only sheet metal enclosures with socket plug top and MCBs single pole and neutral enclosure with a 2 pin and earth plug and socket complete with one SP MCB of 16 Amp rating 240 Volt complete.
Taking down unserviceable geysers 25/35/50 litre capacity of any make opening up for inspection, inlet, outlet and thermostat pipe, washing the inner tank with anti corrosion solution , the inlet & outlet valves, safety valve, dead weight and refixing the geysers in position and testing for proper functioning including soldering/welding where required to stop the leakage and other jobs connected with plumber and mason which would be required in connection with making the geyser functional complete.
Supply only MCB, SPN 32 AMP, 240V, 10 KA (B Curve) complete. All as specified and directed by Enge in charge.
Supply only MCB, SP 06 to 32 AMP 240 V 10 KA (B Curve) complete. All as specified and directed by Enge in charge.
Sub main wiring with 2 run of single core 6 Sqmm FRLS PVC insulated unsheathed cable, 1100v grade with copper multi stranded conductor drawn through and including surface PVC conduit ISI marked medium grade 20mm dia with all fitting and fixing accessories including of 6 Sqmm FRLS PVC insulated unsheathed Copper cable green colour as earth wire connected to earth including taking down existing sub main wiring complete.
All as per serial item 26 here in before but with 2 run of single core 4 Sqmm cable with 4.0 sqmm earth wire. All as specified and directed by Enge in charge.
Supply and fixing of plug top 15/16Amps all as specified and directed by Engineer-in-charge. All as specified and directed by Enge in charge.
M&L for repairing of existing tanks of solar water heater made up of MS galvanized sheet with sheet fabrication ,welding/brazing works at site complete all as specified and directed as per requirement on site .
Supply only bottom cover plates of 25/50 ltr geyser all as specified and directed by Engineer-in-charge. All as specified and directed by Enge in charge.
stage.html
html • 0.06 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .