XEN MED Khellani
EXECUTIVE ENGINEER, Mechanical Division, Khellani Doda
Design Manufacture SITC of 250 KVA 3 Phase Servo Motor Operated Line Voltage Correctors suitable for outdoor installation alongwith Design Manufacture SITC of Electric Control Panel and other allied works like foundation Earthing Cable work
2021_PWDJK_130554_2
MDKD/TS/2021-2022/06
Open Tender
Electrical Works
Turn-key
7 days
DH Ramban
As per SBD
2 documents required · 2 mandatory
₹1,000
XEN MED Khellani-Doda
₹20,000
11 Aug 2021
21 Jul 2021
27 Jul 2021
21 Jul 2021
26 Jul 2021
21 Jul 2021
21 Jul 2021 - 26 Jul 2021
Amount
SCOPE OF WORK
Design, Manufacture, Supply, Installation, Testing & Commissioning of 250 KVA Three Phase Servo Motor Operated Line Voltage Correctors Suitable for outdoor installation with three Warranty conforming to relevant IS Codes and meeting specific requirements (Refer details as laid down in Scope of Work Annexure “A”)
Supplying, Installation, Testing & Commissioning of Cubical Type General Floor Incomer Panel Board suitable for 415 Volt, 3 phase 4 wire 50 Hz AC Supply System including In-comers, Outgoing Bus Bars, interlocking, etc. (Refer details as laid down in Scope of Work Annexure “A”) Supplying, Installation, Testing & Commissioning of Cubical Type General Floor Distribution Panel Board Suitable for 415 Volt, 3 Phase 4 wire 50 Hz AC Supply System including Incomers, Outgoing, Bus Bar, interlocking, etc (Refer details as laid down in Scope of Work Annexure “A”) Chemical earthing of AVR, Incomer & Distribution Panel: S&F of copper chemical earthing and Earth continuity strip of size 32x6 mm fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to wall or any other indicated situation including insulator with bolt for fixing on wall as per site conditions.
Supplying, Laying, Jointing, Testing & Commissioning 1100 Volts Grade LT XLPE insulated PVC sheathed as per IS-7098 (Part 1), 1988 with latest amendments, galvanized steel strips or wire armored, heavy duty electric cables with multi stranded aluminum conductors laid in trenches/passing through pipe/duct/road crossing or fixed on poles walls with suitable size clamps made out of mild steel flat iron including jointing materials such as crimping type lugs made out of mild steel iron including jointing materials such as crimping type lugs brass cable glands heavy duty double compression type etc. for making electrical connection from Incomer Control Panel to AVR, AVR to AMF Panel of DG Set and from AMF Panel of DG Set to Distribution Control Panel. 3.5 core 300 sqmm Armoured Cable approx. (70 meters) Supplying, Laying, Jointing, Testing & Commissioning of 1100 Volts Grade 4 mm sq , 4 core copper power cable laid in trenches/passing through pipe/duct/road crossing or fixed on poles walls with suitable size clamps made out of mild steel flat iron including jointing materials such as crimping type lugs made out of mild steel iron including jointing materials such as crimping type lugs brass cable glands heavy duty double compression type etc. for making electrical connection for making Electric connection between DG Set, Alternator and its control panel around 130 meter in length Note: Rate to be quoted for laying per metre of cable.
Mamta Enterprises
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .