Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹31.1 LAccepted-AOC N A | NA | NA | 121004 | L1 | Accepted-AOC Being lowest tender | |
| 2 | L2₹33.9 L+₹2.3 L (7.17%)Rejected-Finance | L2 | Rejected-Finance Being L2 | |
| 3 | L3₹34.7 L+₹3.1 L (9.81%)Rejected-Finance | L3 | Rejected-Finance Being L3 |
Tender Value
₹35 L
EMD Value
₹70,000
Closing Date
16 Jan 2020, 6:00 pmClosed
Garrison Engineer South Delhi Cantt 110010
Delhi Cantt 110010
SPECIAL REPAIR TO BLOCK-III (QTR NO 17 TO 32) IN DAD PANCHWATI COMPLEX PROVN OF TWO TOILETS AND TWO BATHROOMS IN BLDG NO P-97 (SAINIK INSTITUTE OF 13 KUMAON) PROVN OF INTERNAL ELECTRIFICATION IN BLDG NO P-169 (MT LINE) OF 11 RAJ RIF) AND ADDL/ALT OF
2019_MES_306890_1
GE/DS-80/2019-20
Open Tender
Civil Works
Item Rate
270 days
Garrison Engineer South Delhi Cantt 110010
Please refer Tender documents.
9 documents required · 9 mandatory
₹500
Garrison Engineer South Delhi Cantt 110010
₹70,000
Yes
22 Feb 2020
16 Dec 2019
18 Jan 2020
16 Dec 2019
16 Jan 2020
30 Dec 2019
17 Dec 2019 - 27 Dec 2019
Amount
B/R Works Surface excavation n.exc (not exceeding) 30cm deep and averaging 15cm deep and get ting out in any type of soil complete all as specified and as directed by the Engineer-in-Charge.
Excavation in trenches not exceeding 1.5m wide and not exceeding 1.5m depth for foundation etc for manholes,septic tanks,wells etc not exceeding 10 sqm on plan and not exceeding 1.5m in depth and getting out in any type of soil complete all as specified and as directed by the Engineer-in-Charge.
Returning, filling in approved soft/loose soil, including spreading, levelling, watering and well ramming in layers not exceeding 25cm thick complete all as specified and as directed by the Engineer-in-Charge.
Removing excavated material n exc. 50 m and depositing where directed at a level n exc. 1.5 m above the starting point complete all as specified and as directed by the Engineer-in-Charge.
M&L for Cement concrete 1:4:8 type D-2 (using 40mm graded stone aggregate) as in foundations filling and mass concrete complete all as specified and as directed by the Engineer-in-Charge.
M&L for Cement concrete 1:2:4 Type B1 (using 20mm graded stone aggregate) in lintels upto 1.5m clear span, cills, steps;seismic and other similar bands, plinth course:s, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates and the like including weathering , slightly rounded or chamfered angle and throughting complete including necessary form work all as specified and as directed by the Engineer-in-Charge.
M&L for Brick work with sub class 'B' bricks strainght or curved on plan not exceeding 6m mean radius built in cement mortor (1:6) complete all as specified and as directed by the Engineer-in-Charge.
M&L for Brick work with sub class 'B' bricks strainght or curved on plan to any radius in half thick in CM 1:4 brick wall built in cement mortor complete all as specified and as directed by the Engineer-in-Charge.
M&L for Damp proof course 40mm thick to horizontal or vertical surfaces in Cement Concrete 1:2:4 including neccessary formwork and with WPC as per manufacturer instruction. Note-: WPC shall be measured and paid for seperately
Supply only Integral water proofing compound complete all as specified and as directed by the Engineer-in-Charge.
M&L for RCC M-25 Design Mix as in slabs, supported on walls, landings, balconies, shelves including scaffolding and other T&P in repair complete all as specified and as directed by the Engineer-in-Charge.
S&F TMT bars 10 mm dia & over as in reinforcement of columns, beams, RCC, slabs, chajjas, lintels etc cut to length bent to shape required including cranking, bending, spirally hoping for columns, hooking ends and welding the new reinforcement with old steel bars to receive gunniting treatment over existing surfaces including binding with and incl mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and as directed by the Engineer-in-Charge.
M&L for from work to soffits of suspended slabs such as roof slabs, floor slabs, landing & similar work not exceeding 200mm thick (Horizontal or sloping) for rough finished surfaces complete all as specified and as directed by the Engineer-in-Charge.
M&L for 10 mm thick Cement Plaster in cement mortar 1: 3 on concrete surfaces of ceiling,chajja,etc finished fair and even complete all as specified and as directed by the Engineer-in-Charge.
M&L for preparaing newly plastered surfaces on Ceiling and applying three coats of white wash complete all as specified and as directed by the Engineer-in-Charge.
M&L for 15mm thick Cement plaster in CM (1:4) on fair faces of brick or concrete surface and finished the surface even and smooth without using extra cement complete all as specified and as directed by the Engineer-in-Charge.
M&L for 15mm thick Cement plaster in CM (1:6) on unfair faces of brick or concrete surface and finished the surface even and smooth without using extra cement complete all as specified and as directed by the Engineer-in-Charge.
M&L for preparation of new surface of plaster and applying 3mm thick wall care putty in two layers complete all as specified and as directed by the Engineer-in-Charge.
M&L for applying two coats of distemper oil emulsion, on white or tinted over 3mm thick wall care putty in two layers complete all as specified and as directed by the Engineer-in-Charge.
M&L for applying two coats of Exterior emulsion paint (whether coat / Apex) on white or tinted over existing prepared putty base surface complete all as specified and as directed by the Engineer-in-Charge.
M&L for 100mm thick Cement concrete 1:4:8 type D-2 (using 40 mm graded stone aggregate) as in sub base of floors complete all as specified and as directed by the Engineer-in-Charge.
M&L for 40 mm thick Cement concrete 1:2:4 Type B-1 as in floor surface finished even and fair complete all as specified and as directed by the Engineer-in-Charge.
M&L for Coloured Non Skid ceramic tiles, joint free 7 to 8 mm thick(square/ rectagular) area of each tile exceeding 0.18 sq m but not exceeding 0.38 sqm , in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over 15mm thick screed bed in cement mortor 1:6 complete all as specified and as directed by the Engineer-in-Charge.
M&L for Coloured Glazed ceramic tiles size 450 x 350 x7 mm on vertical surfaces such as skirtings, dados and riser to steps etc over 10mm thick rendring in Cm 1:4 complete all as specified and as directed by the Engineer-in-Charge.
M&L for Hardcore of broken stone or boulders gauge n exc. 63 mm, deposited, spread and levelled in layers under plinth protection 100 mm thick, watered and rammed to a true surface complete all as specified and as directed by the Engineer-in-Charge.
M&L for 75 mm thick Cement concrete type C2 1:3:6 (using 40mm graded stone aggregate) 75mm thick as in plinth protection etc complete all as specified and as directed by the Engineer-in-Charge.
S&F Powder coated anodised aluminium as in frame & shutter of door, window, ventilators and shutter etc. with one or more rebates including jioning cleat for fixing etc. fixed type/louvered/sliding window or ventilators without sash bar, aluminium including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws (minimum thickness of coating powder 50 micron) etc complete all as specified and as directed by the Engineer-in-Charge. Make:- Jindal/ Hindalco.
S&F 4mm thick ordinary quality glass, frosted on one side, in square n exc 0.5 Sqm each pane, fixed with aluminium beading in aluminium window/ventilation etc complete all as specified and as directed by the Engineer-in-Charge
M&L for 12 mm thick Prelaminated particle board,exterior grade, prelaminated both side with decorative choice lamination , fixed in aluminium door of required size complete all as specified and as directed by the Engineer-in-Charge
M&L for Aluminium anodised barrel tower bolts of extruded section , 150 mm long complete all as specified and as directed by the Engineer-in-Charge
M&L for Aluminium anodised butt hinges 75mm size medium duty weight complete all as specified and as directed by the Engineer-in-Charge
M&L for Aluminium anodised butt hinges 100mm size medium duty weight complete all as specified and as directed by the Engineer-in-Charge
M&L for 250mm long Aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast aluminium alloy and fixed complete all as specified and as directed by the Engineer-in-Charge
M&L for 100 mm Aluminium handles, cast type, anodised complete all as specified and as directed by the Engineer-in-Charge
M&L for 25 mm bore Mild steel galvanized steel tubing medium grade with all fittings and fixed complete all as specified and as directed by the Engineer-in-Charge
S&F 25mm gun metal gate Valves with iron wheel head, Screwed both ends for iron pipe complete all as specified and as directed by the Engineer-in-Charge
M&L for 15 mm bore Mild steel galvanized steel tubing medium grade with all fittings and fixed complete all as specified and as directed by the Engineer-in-Charge
M&L for Bib taps, cast copper alloy, fancy type chromium plated, with crutch or butterfly handle, screwed down for iron pipe, 15mm bore of pipe complete all as specified and as directed by the Engineer-in-Charge
M&L for Stop valves, cost copper alloy, fancy type chromium plated, screwed down, high pressure with crutch or butterfly handle, 15 mm bore of pipe complete all as specified and as directed by the Engineer-in-Charge
M&L for Pillar taps, fancy type cast copper alloy, with capstan heads, chromium plated, screwed down high pressure, with or without lettered ‘Hot' or ‘Cold' with long screwed shanks and fly-nuts, screwed for iron pipe and fixed, 15 mm bore of pipe complete all as specified and as directed by the Engineer-in-Charge
M&L for 20mm thick Granite(of any type) work (table rubbed and polished) in steps, jambs, pillars, window- cills,cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite complete all as specified and as directed by the Engineer-in-Charge
S&F vitreous china wash hand basin of size 550x400mm , white flat back, including waste fitting complete all as specified and as directed by the Engineer-in-Charge
S&F Vitreous china wash down water closet pan (pedestal pattern) , white fixed in repair,including sheet cover of closed pattern with flat bottom and mild steel chromium plated or aluminiumised hinging device, complete all as specified and as directed by the Engineer-in-Charge
M&L for Vitreous china squatting pan white Orissa patern size 580x440mm with integral foot rests (excluding flushing cistern & flush pipe) with cast iron 'P' trap incl Cement concrete complete all as specified and as directed by the Engineer-in-Charge
M&L for PVC valve less, Symphonic action type, flushing cistern of capacity 10 liters, low level, white with inlet, ball valve, manually operated with one PVC ball valve horizontal plunger type including provision of 32mm PVC flush pipe of required length and making connections complete all as specified and as directed by the Engineer-in-Charge
S&F vituous china bowl urinal flat back size 465x355x220mm white with grating and union for discharge pipe (excluding flushing cistern, flush pipe, waster pipe) complete all as specified and as directed by the Engineer-in-Charge
S&F for CP cast copper alloy Health Faucet with 1mtr tube & Hook complete all as specified and as directed by the Engineer-in-Charge
S&F in repairs toilet paper holder of viperous china, box type coloured plated ‘D’ type, to walls with chromium plated brass screws complete all as specified and as directed by the Engineer-in-Charge
S&F in repairs brass chromium plated tubular towel rail, 20 mm dia D type , 60 cm long between flanges complete all as specified and as directed by the Engineer-in-Charge
M&L for 1000 ltrs rotational moulded polyethylene water storage tank triple layers (cyclindrical vertical with closed top) fixed in position complete all as specified and directed by Engr-in-Charge
M&L for 25mm bore float valve with epoxy coated aluminium rod and high density plastic ball including GI fitting complete all as specified and as directed by the Engineer-in-Charge
M&L for 75mm Cast iron floor trap, with grating including jointing to waste pipe fixed in cement concrete type B1(1:2:4) complete all as specified and as directed by the Engineer-in-Charge
M&L for 100mm dia Cast iron soil, waste and vent pipes, in any length with or without ears, with cement joints, laid in trenches or in floors
M&L 100mm CI Bends (any radius) or diminishing pieces complete all as specified and as directed by the Engineer-in-Charge
M&L 100mm CI Branch pieces, single (equal or unequal), ordinary or inverted (spigot or socket type) or with parallel branches complete all as specified and as directed by the Engineer-in-Charge
M&L for 50mm Cast iron soil, waste and vent pipes, (Sand Cast) in any length with or without ears with cement joints, fixed on wall complete all as specified and as directed by the Engineer-in-Charge
M&L for PVC connection pipe 15mm size with PTMT nuts of lenth 450mm complete all as specified and as directed by the Engineer-in-Charge
M&L for Reinforced concrete pipe class NP2 150mm bore laid in trenches on concrete bed, to required slope, jointed and tested complete all as specified and as directed by the Engineer-in-Charge
M&L for 110 mm PVC (SWR) pipes double socketed, in any length with rubber ring joints laid in trenches or in floors complete all as specified and as directed by the Engineer-in-Charge
M&L for 150 mm thick Hardcore with Broken stone or boulders of gauge n exe 63 mm deposited, spread and levelled in layers, watered and rolled/rammed to a true surface complete all as specified and as directed by the Engineer-in-Charge
M&L for 100mm thick Cement concrete type C- 2, 1:3:6 (using 40mm graded aggregate) as in sub base complete all as specified and as directed by the Engineer-in-Charge
M&L for Machine pressed precast concrete interlocking paver block any shape and size conforming to IS 15658-2006 of 80 mm thickness, M-40 grade laid over 30mm thick sand cushion and joints grouted in Cement Mortar 1:4 finished smooth complete all as specified and as directed by the Engineer-in-Charge
Dismantling/taking out and removing existing unserviceable cement plaster, loose/unsound weakend cement concrete of any description and in any postiong from existing external surfaces of RCC roof slab/beams/columns depth varying from 25 mm to 90 mm (approx upto 13.35 mtr high from natural ground level) with power driven (HILTI-706) or pneumatic chisel as directed by Engr -in -charge including saw cutting of all edges making square shoulders of the cavities roughening of smooth surfaces scraping out/removing corrosion/all loose scales/rust etc from the visible reinformcement and cleaing the steel reinformemcement complete all as specified and as directed by the Engineer-in-Charge Notes for Item No 64 to 75:- 1. The rates of scaffolding for structural rehabilitation & Guniting up to 04 storey Bldg deemed to be included in the item quoted rate. 2. The dismantling of concrete in RCC members , RCC slabs, cantilever Balcony projections, Balcony columns & beams and other Columns shall be done after necessary backpropping arrangements using steel props to relieve the load carrying members. The rate of backpropping deemed to be included in the item rate. 3. All the site shall be cleaned by the contractor after guniting & Structural rehabilitation including removal of debris outside MOD Land.
M&L for removal of rust from reinforcement completely by rubbing with wire brush or emeray paper and proper cleaning of reinforcements with RUSTKLENE or Sika rust off-100 (Rust converter manufactured by Sika India Pvt. Ltd.) or equivalent in MC Bauchemie India Pvt Ltd or Fosroc Industries Banglore as per manufacturers instruction complete all as specified and as directed by the Engineer-in-Charge
M&L for providing new additional reinforcement bars for RCC roof slab/beams/columns including power drilling holes of appropriate diameters in reinforced or plain cement concrete to minimum depth of 150 mm and up to 200 mm wherever required, fixing the reinforcement in position of TMT bars 8mm dia and over, cut to length, bent to shape required including cranking bending spirally for hooping for columns, hooking ends and binding with mild steel wire (annealed) not less than 0.9mm dia or securing with clips/ welding etc. quality conforming to FE-410-S or Fe-410-O complete all as specified and as directed by the Engineer-in-Charge
All as per Item No. 66 above but TMT bars 10 mm dia and over.
M&L for providing and inserting non-returnable nozzle 12 mm dia 350 mm c/c up to depth from 25 to 60mm or half the thickness of member whichever is less for injecting through pressure pump low viscosity BULIDCORROBIT and BUILDPOXY-LV or Sika FerroGard-903 (Corrosion inhibitor manufactured by Sika India Pvt. Ltd.) and Sikadur 52 (Low viscous epoxy manufactured by Sika India Pvt. Ltd.) or equivalent in MC Bauchemie India Pvt Ltd or Fosroc Industries Banglore, , with two operation pumping or as per manufacturer instructions complete all as specified and as directed by the Engineer-in-Charge (Note:-The chemical shall be measured and paid for seperately under respective item)
Supply and Injection of Corrosion Inhibitor BULIDCORROBIT or Sika FerroGard-903 (Corrosion inhibitor manufactured by Sika India Pvt. Ltd.) or equivalent in MC Bauchemie India Pvt Ltd or Fosroc Industries Banglore through the nozzles using a pressure pump with a pressure of 2 Kg/Sqcm and once the material overflowing from the next nozzles , the operation shall be shifted to other neighbouring nozzle complete all as specified and as directed by the Engineer-in-Charge
Supply and Injection of low viscosity epoxy BUILDPOXY-LV or Sikadur 52 (Low viscous epoxy manufactured by Sika India Pvt. Ltd.) or equivalent in MC Bauchemie India Pvt Ltd or Fosroc Industries Banglore as approved by GE complete all as specified and as directed by the Engineer-in-Charge
M&L for application of zinc rich primer coat on reinforcement bars BUILDCOTE (ZP) or Friazinc-R (Primer manufactured by Sika India Pvt. Ltd.) and shall be applied in such a manner that primer shall be a coating of atleast 40 micron complete as per manufacturers instruction complete all as specified and as directed by the Engineer-in-Charge
M&L for providing & applying of BUILDBOND or Sikadur 32 LP (Epoxy based bonding agent manufactured by Sika India Pvt. Ltd.) complete all as specified and as directed by the Engineer-in-Charge
M&L for application of micro concrete BUILDMICROKRIT or SikaRep Microcrete-4 (High strength microconcrete manufactured by Sika India Pvt. Ltd.) or equivalent in MC Bauchemie India Pvt Ltd or Fosroc Industries Banglore (50mm average thickness) including neccessary formwork required complete all as specified and as directed by the Engineer-in-Charge
M&L for providing & applying 20mm thick polymeric cement mortar plaster in CM 1:4 complete all as specified and directed and directed by Engineer-in-Charge/GE. (Note Polymeric waterpriifing compound i.e. Buildcrete or Equivallent of M/s Foscroc & M/s Sika will be added @ 2% by weight of cement)
M&L for providing & applying a coat of polyurethane based clear coating BUILDCOTE (PUR) or Sika PU UR (Polyurethane based coating manufactured by Sika India Pvt. Ltd.) or equivalent in MC Bauchemie India Pvt Ltd or Fosroc Industries Banglore as approved by GE complete all as specified and as directed by the Engineer-in-Charge
Dismantling of RCC fins, parapets,slab, facia, chajjas etc carefully without disturbing the existing re-inforcement complete all as specified and as directed by the Engineer-in-Charge
M&L for form work to chajjas,slab, shelves and similar works including sides complete all as specified and as directed by the Engineer-in-Charge
M&L for reinforced cement concrete type B1 (1:1.5:3) using 20 mm graded stone aggregate as in chajja, slabs, shelves and similar works complete all as specified and as directed by the Engineer-in-Charge
Demolition of brick work built in cement mortar incl quoins, arches, pillars etc complete all as specified and as directed by the Engineer-in-Charge
Taking down cement plaster on brick/concrete surface including racking out joints heacking for key scrubbing down with water etc complete all as specified and as directed by the Engineer-in-Charge
M&L for preparation of new plastered surfaces of ceiling and applying three coats of white wash complete all as specified and as directed by the Engineer-in-Charge
M&L for prepration of newly plastered surfaces of walls and applying two coats of oil bound distemper including one coat of priming complete all as specified and as directed by the Engineer-in-Charge
M&L for preparation of new plastered surfaces and applying three coats of white wash on surfaces of walls complete all as specified and as directed by the Engineer-in-Charge
M&L for prepapring old plastered surfaces and applying a coat of white wash on wall complete all as specified and as directed by the Engineer-in-Charge
M&L for preparation of old plastered surface by complete removal of existing treatment on wall or ceilings and applying two coats of cement base paint, white or tinted ( colour & shade as approved by GE) complete all as specified and as directed by the Engineer-in-Charge
M&L for preparation of old painted steel surfaces of any description over 10 cm in girth or width not otherwise described and applying one coat of synthetic enamel paint complete all as specified and as directed by the Engineer-in-Charge
Taking down old steel / Aluminium Window chowkats with shutters not exceeding 1.5 Sqm each (without taking off shutters from the frames) complete all as specified and as directed by the Engineer-in-Charge
Taking down old Steel/ Aluminium Window chowkats or frames with shutters (without taking off shutters from the frames) exceeding 1.5 Sqm but not exceeding 4 Sqm each complete all as specified and as directed by the Engineer-in-Charge
M&L for poweder coated Aluminium anodised three way track sliding windows of frame size 92 mm x 31.75 mm x 1.5mm thickness (section no. 20831 of JINDAL) and of shutter size 40 mm x 18 (with 9.00 mm interlocking legs) x 1.45 mm thick (section no. 20737 of JINDAL) section(two shutter glazed, covering half of span of opening each & one shutter sketlon covering half of span of opening ) incl provn for making windows air tight, including 95mm aluminium handle with spring lock , stainless steel wire cloth, 0.45 mm nominal dia of wire and average width of aperature 1.4mm and fixed with steel wire stapples and 5mm thick plain glass including necessary fitting/ fixture/ aluminium snap beads complete all as specified and as directed by the Engineer-in-Charge Note: Measurement shall be taken for clear opening i.e. out to out of window frame as a whole including all fittings and fixtures and no extra shall be paid for separately.
M&L for 6mm dia powder coated Aluminium decco grill section no-104, 100mm aperture of hexogenal design and pattern as approved complete all as specified and as directed by the Engineer-in-Charge
S&F Galvanised mild steel wire cloth, 0.63mm nominal dia or wire and Sqm average width or aperature 1.40mm, fixed with tinned tacks or galvanised wire staples complete all as specified and as directed by the Engineer-in-Charge
Dismantling and breaking up CI pipes set in CM, 100/75 mm dia pipe complete all as specified and as directed by the Engineer-in-Charge
S&F in repairs CI soil, waste and vent pipe in any length with or without ears, with cement joints, fixed to walls of 100 mm dia sand cast pipe complete all as specified and as directed by the Engineer-in-Charge
S&F in repairs CI soil, waste and vent pipe in any length with or without ears, with cement joints, fixed to walls of 75 mm dia sand cast pipe complete all as specified and as directed by the Engineer-in-Charge
S&F in repairs CI Bends (any radius ), diminishing pieces or tapers of 100 mm dia fitted with oval access door complete all as specified and as directed by the Engineer-in-Charge
S&F in repairs CI Bends (any radius ), diminishing pieces or tapers of 75 mm dia fitted with oval access door complete all as specified and as directed by the Engineer-in-Charge
S&F in repairs Cast iron branch pieces, single (equal or unequal), ordinary or inverted (spigot or socket type) or with parallel branches, 100 mm bore with cement joints, fitted with oval access doors complete all as specified and as directed by the Engineer-in-Charge
S&F in repairs Cast iron branch pieces, single (equal or unequal), ordinary or inverted (spigot or socket type) or with parallel branches, 75 mm bore with cement joints, fitted with oval access doors complete all as specified and as directed by the Engineer-in-Charge
S&F 100 mm cast iron sanitary connections short connections pipe of length upto 300 mm complete all as specified and as directed by the Engineer-in-Charge
S&F in repairs Stack clamps out of 50mm x 5mm flat iron and 16mm dia round iron stays, including bolts and nuts and securing ends of stays to wall or roof, for 100 mm bore pipes complete all as specified and as directed by the Engineer-in-Charge
S&F in repairs Stack clamps out of 50mm x 5mm flat iron and 16mm dia round iron stays, including bolts and nuts and securing ends of stays to wall or roof, for75mm bore pipes complete all as specified and as directed by the Engineer-in-Charge
Extra over cast iron pipe and fittings for lead joints if provided in lieu of cement joints for 100 mm dia CI Pipes complete all as specified and as directed by the Engineer-in-Charge
All same as per ser item No 102 above but for 75mm CI pipes
Taking down rain water pipe (any size) or pattern incl all fittings, head shoes, bends swan necks etc incl cleaning or re-fixing or removal to store(measured overall as fixed along the centre line over fittings and accessories complete all as specified and as directed by the Engineer-in-Charge
S&F in repairs PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to walls, of 110 mm dia complete all as specified and as directed by the Engineer-in-Charge
Demolition of cement concrete (unreinforced) in ground floors and paving not exceeding 15cm thickness (below or above ground level) complete all as specified and as directed by the Engineer-in-Charge
M&L for Cement concrete 1:3:6 type C1 using 20mm graded stone aggregate in plinth protection, 75mm thick, finished fair and even without using extra cement, complete all as specified and as directed by the Engineer-in-Charge
Forming Construction joint 30mm deep x 10mm wide filled with sealing compound grade 'A' complete all as specified and as directed by the Engineer-in-Charge
S&F for FRP window horizontal shade (Chhajja) for sun shade and protect to rain, thickness and weight as per manufacturers instruction, fixed with screw with drilling holes in the walls and surface make up with the existing surface with plaster and cement base paint/ appex including existing demolition and waste material remove from the site. colour will be approved by GE and complete all as specified and as directed by the Engineer-in-Charge
Dismantling floor or hearth or wall tiling including cement mortar bedding (but not backing) any description and thickness n.exc 25 mm and removal of rubbish off the premises all as directed by the Engr-in-Charge complete all as specified and as directed by the Engineer-in-Charge
M&L for coloured joint free non skid ceramic tiles 7 to 8mm thick (square/rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, in floors etc set & jointed in neat cement slurry & pointed in coloured cement to match for laying floor finish complete all as specified and as directed by the Engineer-in-Charge. Make;-Kajaria(Group-V)/Jhonson & Jhonson / Somany.
S&F glazed ceramic tiles in colour, of size 300mm x 200mm x7mm thick, on vertical surfaces such as dados etc, set and jointed in neat cement slurry and pointed in white cement complete all as specified and as directed by the Engineer-in-Charge
M&L for complete removal of existing treatment from walls by electric operated grinder machine and applying 1-2 mm thick wall care putty finished even and smooth and applying two coats of oil emulsion distemper over a coat of primer complete all as specified and as directed by the Engineer-in-Charge
M&L for prepapring old plastered surfaces and applying a coat of white wash on ceiling complete all as specified and as directed by the Engineer-in-Charge
S&F rolled mild steel in Fe 410-W(Gde-E-250) quality-A, framed work as in doors or gates of angle or other section with gusset plates, etc., complete, doors etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings and hanging; also fastening and fixing complete all as specified and as directed by the Engineer-in-Charge
Sewage Work Excavation in trenches n.exc. 1.5m wide and n.exc. 1.5m in depth for manholes and sewage line and getting out in soft/loose soil complete all as specified and as directed by the Engineer-in-Charge
All same as per ser item No. 116 above but depth exc 1.5m but n.exc. 3.00m
Removing excavated materials exc 50m but nexc 250m at a level n.exc. 1.50 above the starting point and depositing where complete all as specified and as directed by the Engineer-in-Charge
Demolition of cement concrete of any description and any position complete all as specified and as directed by the Engineer-in-Charge
Demolition and breaking up drain pipe (salt glazed were) set in cement mortar 150mm internal dia of pipe complete all as specified and as directed by the Engineer-in-Charge
Demolition and breaking up drain pipe (salt glazed were) set in cement mortar 200mm internal dia of pipe complete all as specified and as directed by the Engineer-in-Charge
M&L for concrete bed to drain in PCC 1:3:6 type C2 incl packing under and haunching against the sides of pipes after they are laid and tested in bore of pipe 150mm dia pipe complete all as specified and as directed by the Engineer-in-Charge
M&L for concrete bed to drain in PCC 1:3:6 type C2 incl packing under and haunching against the sides of pipes after they are laid and tested in bore of pipe 200mm dia pipe complete all as specified and as directed by the Engineer-in-Charge
Supply and Fixing salt glazed stone ware drain pipe laid and jointed of 150mm bore of pipe ( Internal dia of pipe) complete with collars complete all as specified and as directed by the Engineer-in-Charge
Supply and Fixing salt glazed stone ware drain pipe laid and jointed of 200mm bore of pipe ( Internal dia of pipe) complete with collars complete all as specified and as directed by the Engineer-in-Charge
M&L for Cutting existing manholes for connection new drain pipe making good to pipe and rendering cutting out existing benching for and forming branch channel (1/2 round or 3/4 section) in cement concrete 1:2:4 type B1 smooth finished and benching as required internal dia of pipe 150mm complete all as specified and as directed by the Engineer-in-Charge
S&F 180 x 150mm Salt-glazed stoneware gully traps, square or round mouthed, type `P' complete all as specified and as directed by the Engineer-in-Charge
M&L for brick work with sub class 'B' bricks straight or curved on plan exc 6m mean radius in cement mortar 1:4 as in manholes/drain complete all as specified and as directed by the Engineer-in-Charge
M&L for 15mm thick cement Plaster in Cement Mortar 1:4 on faces of brick/ concrete surface, finished even and smooth without using extra cement complete all as specified and as directed by the Engineer-in-Charge
M&L for cement concrete 1:2:4 type B1 (using 20mm grade stone agregate) as in coping etc including from work complete all as specified and as directed by the Engineer-in-Charge
M&L for 110mm dia PVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in trenches or in floors complete all as specified and as directed by the Engineer-in-Charge
M&L 110 mm dia PVC (SWR) bends any radius complete all as specified and as directed by the Engineer-in-Charge
S&F 100 mm dia Cast iron (Sand Cast ) soil, waste and vent pipes, in any length with or without ears, with cement joints, fixed to wall complete all as specified and as directed by the Engineer-in-Charge
-BLANK-
S&F 75 mm dia Cast iron (Sand Cast ) soil, waste and vent pipes, in any length with or without ears, with cement joints, fixed to wall complete all as specified and as directed by the Engineer-in-Charge
M&L for 75mm bends (any radius) or diminishing pieces complete all as specified and as directed by the Engineer-in-Charge
E/M Works M&L for Sub Main wiring complete multistrand copper conductor cable 2 runs of 6 Sq mm for phase and neutral and 1 run of 4 Sqmm for earth wire drawn through existing concealed steel/PVC conduit wiring in wall not less than 25 mm dia with all fittings like tees, bends, junction/terminal boxes etc as per site requirement complete all as specified and as directed by the Engineer-in-Charge Note:- Phase should be of Red /Yellow/Blue, neutral should be of back and earthing wire should be of green colour. Two runs of cable for phase/ neutral and one run of cable for earth will be measured and paid as one unit length).
M&L for existing concealed point wiring complete with 1.5 sq mm as per IS specification FR PVC insulated unsheathed stranded copper conductor cable drawn through and including siutable size of existing pvc conduit including pvc flexibal pipe and all assessories complete in walls and in Steel terminals boxes suitable for switches, sockets, fan regulator etc with screw, cup washer and 1.5 sq mm copper earth continuity wire connected to celing rose to fitting and earth dolly completeall as specified and directed. Note-the rate is inclusive cutting/ chasing and making good disturbed surface with CM 1:3 and same surface finshes with the adjoining surface of disturbed area with OBD/colour wash/ white wash complete all as specified and as directed by the Engineer-in-Charge
One light/fan point controlled by one way switch
One switch socket outlet type 5 pin 6 amp on same board
All same as per item No 138 above but 2.5 sq mm cable and 1.5 sq mm copper earth dolly for one switch socket outlet type 5 pin 6 Amp on same board
All same as per item No 138 above but 2.5 sq mm cable and 2.5 sq mm copper earth dolly for the following
One switch socket outlet type 5 pin 16 Amp on independent board.
One sheet metal enclosure point for geyser on independent board.
Supply and fixing surface mounting tube light fitting, 1X20 watt, 230 volts 4 ft LED CRCA batten including retropit T8 glass (LED tube rod) with and including, internally pre wired with all accessories and including connecting up to fitting, complete all as specified and as directed by the Engineer-in-Charge Make-C&S Cat Part No TARA-Mi/20 or equivlent in Havells/Philips/Benlo
Supply and fixing surface mounting tube light fitting, 1X10 watt, 230 volts 2 ft LED CRCA batten including retropit T8 glass (LED tube rod) with and including, internally pre wired with all accessories and including connecting up to fitting, complete all as specified and as directed by the Engineer-in-Charge Make-C&S Cat Part No TARA-M/10 or equivlent in Havells/Philips/Benlo
S&F 0-4 step type electronic regulators for ceiling fan 1200 mm sweep, 240 volts, complete all as specified and as directed by the Engineer-in-Charge
S&F exhaust fans, AC single phase 230 volts/240 volts of size 300 mm . sweep with louver and connecting up with replacement of cable T/C flexible cable of size:- 0.50 Sqmm from ceiling rose / connection and including taking down of old exhasut fan and depositing to MES store yard, complete all as specified and as directed by the Engineer-in-Charge
S&F ceiling rose, two to three terminals complete all as specified and as directed by the Engineer-in-Charge
S&F switch piano flush type single pole one way 5 Amp complete all as specified and as directed by the Engineer-in-Charge
S&F socket 2 in 1, 3 pin, 5 Amps & 15 Amp flush type complete all as specified and as directed by the Engineer-in-Charge
S&F switch piano flush type single pole one way 15 Amp complete all as specified and as directed by the Engineer-in-Charge
S&F socket 2 in 1, 3 pin 5&15 Amps flush type complete all as specified and as directed by the Engineer-in-Charge
S&F SPN DB 8 way double door type with metal door and IP 43 protetions flush mounting for MCBs & connecting complete all as specified and as directed by the Engineer-in-Charge
Supply and fixing MCB DP 40 Amps 'C' series, breaking capacity 10 KA, 'C' curve 240 volts, 50 Hz including necessary incoming and out going electric connection with suitable size of copper lugs etc complete all as specified and as directed by the Engineer-in-Charge
Supply and fixing MCB SP 5 to 32 Amps 'C' series, breaking capacity 10 KA, 'C' curve 240 volts, 50 Hz including necessary incoming and out going electric connection with suitable size of copper lugs etc complete all as specified and as directed by the Engineer-in-Charge
Supply and fixing TPN 100 Amps 4 pole 415 volts fixed type with breaking capacity 36 KA 415 volts, including necessary incoming and out going electric connection with suitable size of copper lugs etc complete all as specified and as directed by the Engineer-in-Charge
S&F water heater storage type, electric driven, capacity 50 litres, Inner container of Copper material, including taking down of old geyser and depositing to MES store yard and connecting up the geyser with replacement of cable three core cable of size 2.50 Sqmm by means of plug top 16 Amps complete all as specified and as directed by the Engineer-in-Charge Make-Havells Product No. GHWAMESWH050 or equivalent as approved by GE.
S&F in replacement concealed double door sheet metal enclosures with socket plug top and 20 amps MCBs for geyser complete all as specified and as directed by the Engineer-in-Charge
M&L for Earthing complete with galvanized steel earth plate electrode 600 x 600 x 6.3mm thick buried directly in ground (earth pit not less than 2.25 mtr deep below normal ground level) with top edge of the plate not less than 1.5 mtr below normal ground level connected to galvanized iron strip by means of bolts, nuts, check nuts and washers of galvanised iron all as shown in electrical plate No. 5 connected to earthing test point and testing on completion and including test point termination, complete all as specified and as directed by the Engineer-in-Charge Note:-The cost of excavation and earth work, PCC pit and CI cover, funnel & watering pipe, wiremesh, charcoal dust and common salt and 15 mm dia medium grade GI pipe as protection to earth lead wire shall be deemed included in the unit rate for earthing.
Supply and laying and testing cable XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) 1100 volts with stranded Aluminium conductors of size 6 sq mm 2 core complete all as specified and as directed by the Engineer-in-Charge
Excavation in trenches not exc 1.5 mtr wide and not exc 1.5 mtr in depth and getting out in hard/ dense soil complete all as specified and as directed by the Engineer-in-Charge
M&L for unwashed sand cushioning below and around cable in trenches with river sand complete all as specified and as directed by the Engineer-in-Charge
Returning/ filling incl spreading, leveling, watering and ramming in hard/ dense soil complete all as specified and as directed by the Engineer-in-Charge
Supply and laying brick with sub class 'B' straight for cable cover complete all as specified and as directed by the Engineer-in-Charge
Note:- The contract sum shall be after deducting the amount of Credit shown in Credit Schedule of this Tender.
M/S.Parmod Johar
M/S.M.S.Devi.Const.Co
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .