| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹45.9 LAccepted-AOC NO 1A 1 SHALOM VALLUVAR STREET SIVANANDHA COLONY COIMBATORE TAMIL NADU 641 012 | COIMBATORE | TAMIL NADU | 641012 | L1 | Accepted-AOC BEING LOWEST TENDER. L1 | |
| 2 | L2₹48.7 L+₹2.4 L (5.14%)Rejected-Finance 16 176 A BHARATHI PURAM NAGAI NAGAR DINDUGUL 3 | DINDUGUL | DINDIGUL | TAMIL NADU | L2 | Rejected-Finance BEING NOT LOWEST TENDER. | |
| 3 | L3₹49.2 L+₹2.9 L (6.24%)Rejected-Finance D 235 ADG P CHENNAI | CHENNAI | TAMIL NADU | 600001 | L3 | Rejected-Finance BEING NOT LOWEST TENDER. | |
| 4 | L4₹49.8 L+₹3.5 L (7.53%)Rejected-Finance C 150 ADG P CHENNAI | L4 | Rejected-Finance BEING NOT LOWEST TENDER. | |
| 5 | L5₹50.2 L+₹3.9 L (8.48%)Rejected-Finance NO 1C C L C WORKS ROAD NEW COLONY CHROMEPET CHENNAI 600044 | CHENGALPATTU | TAMIL NADU | 600044 | L5 | Rejected-Finance BEING NOT LOWEST TENDER. |
| Sl No | Description | Qty | Unit | shalom constructions L1 | LAKSHMI ELECTRICAL ENTERPRISES L5 | S KUMARAN L2 | S.RAMACHANDRAN L4 | N SARAVANAN L7 | M/s.Sai Agency L6 | T C KARUNANITHI L3 |
|---|---|---|---|---|---|---|---|---|---|---|
| 1.00SCHEDULE A BOQ | ||||||||||
| 2.00 | Attending unserviceable/ non functional hanger/wall/surface (for lights etc of any type/size fitted on poles/walls/post/pillars/hangers etc) by deploying technically qualified and experinced techinicians to find out defective/taking out unserviceable parts such as electronic driver, pvc insulated copper conductor cable for connecting street light fittings etc and repairing by changing the defective parts including minor repair to cable connection/loose connection, screws,nuts & bolts and insulation tap to insulate the LT joint etc and testing complete all as specified and as directed for at complete AF Station Sulur. | 845 | Each Job | 290 ₹2,45,050 | 320 ₹2,70,400 | 320 ₹2,70,400 | 420 ₹3,54,900 | 269 ₹2,27,305 | 263 ₹2,22,235 Lowest | 275 ₹2,32,375 |
| 2.01Note for item No 02 : The following items are deemed to be inclusive of quoted rate :- | ||||||||||
| 2.02(a) The above job shall be carried out by a trained skilled electrician shall be produced before commencement of work. | ||||||||||
| 2.03(b) 'Supply only' items to be delivered/ supplied to AGE E/M store yard as per qty asked by Engineer-in-Charge with in one calender month from the date of commencement of contract and these items will be issued from AGE E/M store yard for attending unserviceable/ defective street light complaints. | ||||||||||
| 2.04(c) Contractor or his Authorised Representitive has to inspect all Hanger/flood Lights on Daily basis at their own arrangement between 7.00 PM to 9.00 PM and maintain the record in Register which will be put up to Engineer-in-Charge/ JE on the very Next day. | ||||||||||
| 2.05(d) A Joint Inspection for Serviceability of all Hanger Lights will be carried out from 7.00 PM to 9.00 PM on every FRIDAY by Engineer-in-Charge/ JE (E/M)/ User alongwith Contractor or his authorised Representitive. | ||||||||||
| 2.06(e) Contractor has to arrange own T&P for repairing and testing of the Street/ Security Lights, defect rectification of Cables, etc. and to check the serviceability after repair. | ||||||||||
| 2.07(f) Quoted Unit Rate shall deemed to be inclusive of attending any breakdown of Hangers Lights during night. Contractor has to arrange Electrician and Helper and all necessary T&P and Equipments to remove the breakdown. Fault will be intimated through Telephone/ SMS. | ||||||||||
| 2.08(g) In case of any delay in attending the complaint more than 12 hrs after handing over routine/urgent work, the contractor shall be liable to pay the penalty as described in penalty clause given here as under. | ||||||||||
Tender Value
Refer Docs
EMD Value
₹96,000
Closing Date
16 Oct 2025, 6:00 pmClosed
GE AF
KANGAYAMPALYAM
REPAIR/ MAINT OF INTERNAL ELECTRIFICATION FITTINGS, FIXTURE, MAIN DISTRIBUTING BOARDS, BLDG EARTHING, ALL TYPE OF FANS, SUB MAIN UTILITIES AT LCA, ETB, MCCBS, DWR MSG COMPLEX ETC IN TECH AREA AT AF STN SULUR
2025_MES_730667_1
8795/E8
Open Tender
Miscellaneous Works
Item Rate
270 days
GE AF SULUR
Please refer to tender document.
7 documents required · 7 mandatory
₹500
GE AF SULUR
₹96,000
22 Dec 2025
12 Sept 2025
18 Oct 2025
12 Sept 2025
16 Oct 2025
25 Sept 2025
15 Sept 2025 - 23 Sept 2025
Amount
SCHEDULE A BOQ
Attending unserviceable/ non functional hanger/wall/surface (for lights etc of any type/size fitted on poles/walls/post/pillars/hangers etc) by deploying technically qualified and experinced techinicians to find out defective/taking out unserviceable parts such as electronic driver, pvc insulated copper conductor cable for connecting street light fittings etc and repairing by changing the defective parts including minor repair to cable connection/loose connection, screws,nuts & bolts and insulation tap to insulate the LT joint etc and testing complete all as specified and as directed for at complete AF Station Sulur.
Note for item No 02 : The following items are deemed to be inclusive of quoted rate :-
(a) The above job shall be carried out by a trained skilled electrician shall be produced before commencement of work.
(b) 'Supply only' items to be delivered/ supplied to AGE E/M store yard as per qty asked by Engineer-in-Charge with in one calender month from the date of commencement of contract and these items will be issued from AGE E/M store yard for attending unserviceable/ defective street light complaints.
(c) Contractor or his Authorised Representitive has to inspect all Hanger/flood Lights on Daily basis at their own arrangement between 7.00 PM to 9.00 PM and maintain the record in Register which will be put up to Engineer-in-Charge/ JE on the very Next day.
(d) A Joint Inspection for Serviceability of all Hanger Lights will be carried out from 7.00 PM to 9.00 PM on every FRIDAY by Engineer-in-Charge/ JE (E/M)/ User alongwith Contractor or his authorised Representitive.
(e) Contractor has to arrange own T&P for repairing and testing of the Street/ Security Lights, defect rectification of Cables, etc. and to check the serviceability after repair.
(f) Quoted Unit Rate shall deemed to be inclusive of attending any breakdown of Hangers Lights during night. Contractor has to arrange Electrician and Helper and all necessary T&P and Equipments to remove the breakdown. Fault will be intimated through Telephone/ SMS.
(g) In case of any delay in attending the complaint more than 12 hrs after handing over routine/urgent work, the contractor shall be liable to pay the penalty as described in penalty clause given here as under.
(h) The penalty shall be applicable to the contractor if the delay is noticed by the JE/Engr-in-Cahrge more than twelve hrs after handing over works of urgent nature to the contractor. The JE/Engr-in-Charge shall handover the slip containing specification of work to the contractor by lodging the time and signature of contractor be obtained on slip. The contractor shall attend the complaint immediately and shall report to Engr-in-Charge with in 12 hrs. The contractor will keep his tradesmen in stand by for attending any routine / urgent works from the executive. If the nature of job is such that the work cannot be completed within period of 12hrs then the facts shall be brought to the notice of the GE/Engr-in-Charge and the period for the working to the complaint shall be decided by the GE/EIC. If the delay is more then twelve hrs period and the GE is not satisfied with the reason for delay then penalty at the double rate per job shall be deducted from the dues of the contractor. Please note that this penalty is exclusively other then the condition 56 of IAFW - 2249 and shall be treated as interim condition of the contract and shall be enforceabove as and when delay in individual job is noticed and no claim whatsoever on this account shall be entertained by the Deptt. The decision of the Accepting Officer is this regards shall be final and binding.
(j) Contractor has to ensure serviceability of Hanger lights on Daily basis in any Weather Condition at their own arrangement.
(k) Contractor shall provide conveyance to the deployed labour for maintaining the services without any extra cost to department.
(l) Vehicle mounted ladder for maintaining services shall be provided by the contractor at no extra cost to department.
(m) Materials required for the repairing of the lights shall be measured and paid separately under respective item(s). But labour required for taking down, dismantling, repairing and replacing parts and reinstalling and testing the street lights fittings shall deemed to be included in the rate quoted.
(n) Necessary T&P, Safety Belt, Vehicle, Ladder, etc. will be arranged by the Contractor and Cost for the same shall deem to be included in the Quoted Unit Rate.
(o) All safety measures and provn of all safety devices, first aid box etc shall be provided by the contractor. Contractor will be solely responsible for full safety of the persons deployed for providing the services and department will have no liability for any type of accident/injury of any type. Unit rate quoted will be deemed to include the cost of the same and no extra payment shall be made on this part.
(p) All type of T & P, PVC insulation tapes, minor nuts/ bolts/ washers etc required for maintaining the services shall be provided by the contractor without any extra cost to department.
(q) Attending and repairing complaint for one light of any type shall be measured and paid as one Job.
(r) Earth work (if necessary at Site) for removing of any Cable Fault will be Measured and Paid under respective Items.
(s) The contractor shall maintain a record of all urgent work at and if the work is repeated due to poor workmanship, he will be liable to repair the same without any extra expenditure to the Govt.
(t) Contractor shall provide contact details of his responsible person(s) for any emergency.
(u) Any Materials replaced which are not specified in SCHEDULE OF CREDIT will be deposited to MES STORE YARD without any extra Cost to the Department.
Disconnecting & taking out unserviceable one and replacemet with new electronic Driver with input voltage 220 to 270Volt and output voltage suitable for LED light fitting of capacity 10 to 25 watt, complete all as specified and as directed.
Disconnecting & taking out unserviceable one and replacemet with new electronic Driver with input voltage 220 to 270Volt and output voltage suitable for LED light fitting of capacity 30 to 45 watt, complete all as specified and as directed.
Disconnecting & taking out unserviceable one and replacemet with new electronic Driver with input voltage 220 to 270Volt and output voltage suitable for LED light fitting of capacity 60 to 90 watt, complete all as specified and as directed.
Disconnecting & taking out unserviceable one and replacemet with new electronic Driver with input voltage 220 to 270Volt and output voltage suitable for LED light fitting of capacity 100 to 110 watt, complete all as specified and as directed.
Disconnecting & taking out unserviceable one and replacemet with new electronic Driver with input voltage 220 to 270Volt and output voltage suitable for LED light fitting of capacity 140 to 160 watt, complete all as specified and as directed.
Disconnecting & taking out unserviceable one and replacemet with new MCCB four pole, 125 Amp ultimate breaking capacity not less than 16 KA complete conforming to IEC -61439-1 complete all as specified and as directed.
Disconnecting & taking out unserviceable one and replacemet with newmetal clad switch socket triple pole and earth enclosure with three pin and earth plug with socket complete with on triple pole 32 Amps, 415 Volts MCB complete all as specified and as directed.
Disconnecting & taking out unserviceable one and replacemet with new metal clad switch socket triple pole and earth enclosure with three pin and earth plug with socket complete with on triple pole 63 Amps, 415 Volts MCB complete all as specified and as directed.
M&L for taking down of ceiling fan of size 1200/1400mm for safety checking by replacing defective parts/painting/rewinding and re-fixing the ceiling fan after repairs,all as specified and as directed by Engr-in-charge. (Note:- The cost for replacement of unserviceable parts of minor nature such as screws, lugs, insulation tape, nuts, bolts, washers etc after cleaning the metal surface, greasing/lubricant etc to make it functional and making connection by replacing PVC insulated unsheathed cable of copper conduct of size 1.5 Sqmm from ceiling rose/ connector fan (minimum 0.50 Mtr length) including cost of labour for taking down defective parts are deemed to be inclusive in quoted rate all as directed.
Note for item No 11 :- The following items shall be deemed to be inclusive in the quoted rate (a) In each job, checking the functioning of fan including its connections, cleaning of fan, greasing of fan and mechanical check i.e. tightening of loose screw, nuts, bolts, etc are inclusive in unit quoted rate.
(b) The above job shall be carried out by a trained electrician having qualified in ITI ( electrician Trade), documentary proof of the education of tradesman shall be produced, before commencement of work.
(c) The entire job will be carried out in Air Force stn Sulur and necessary documents showing qtr No, bldg No supported with user signature shall be prepared as per format directed by Engr-in-charge and will be deposited to concerned JE (E/M) within 24 hrs.
(d) Maitenance of documents ie complaint slip/complaint register & other stationery required shall be of contractor's responsibility.
(e) Necessary T&P such as ladder, required manpower for taking down and refixing after repair shall be of contractor's responsibility.
(f) All types of T&P, PVC insulation tape, minor nuts, bolts, washers etc required for maintaining the services shall be provided by contractor without any cost to the department.
(g) Any fan found defective/not working shall be brought to AGE E/M store yard & re-fixed after repairing.
(h) In case of major defects, entire job shall be completed within 10 days from the date of registration of complaint, failing which penalty charges @100/- per day shall be recovered.
(j) In case of minor defects, entire job shall be completed within12 hrs from the time of registration of complaint, failing which penalty charges @ 50/- per job shall be recovered.
(k) The contractor shall maintain a record of all urgent/ routine works and if the work is repeated due to poor workmanship, he will be liable to repair the same without any extra expenditure to the Govt.
Disconnecting & taking out unserviceable one and replacemet with new rotor of ceiling fan of any size
Supply and fix fan canopies for ceiling fan size of 1200mm/1400mm
Disconnecting & taking out unserviceable one and replacemet with new gun metal bush of suitable size for ceiling fan 1200mm /1400 mm sweep
Disconnecting & taking out unserviceable one and replacemet with new fan bearing suitable for ceiling fan 1200mm /1400 mm sweep (bearing with 8 balls shall be used )
Disconnecting & taking out unserviceable one and replacemet with new down rod for ceiling fan with 15mm dia (of length not less than 45cm and not more than 60cm) with hanging clamps for ceiling fan complete all as specified and directed.
Disconnecting & taking out unserviceable one and replacemet with new Rubber reel bushes for ceiling fan of size 1200/1400mm
Disconnecting & taking out unserviceable one and replacemet with new 'U' clamp for hanging ceiling fan with all nuts, bolts and washers.
Disconnecting & taking out unserviceable one and replacemet with new outer body of ceiling fan of any size
Disconnecting & taking out unserviceable one and replacemet with new blades (made of aluminum) suitable for 1400mm sweep ceiling fan of any make with set of screws complete all as specified and directed.
Disconnecting & taking out unserviceable one and replacemet with new safety pins 40mm to 50mm long with nuts and bolt with washers for ceiling fan of size 1200/1400mm
Disconnecting & taking out unserviceable one and replacemet with new blades (made of aluminum) suitable for 1200mm sweep ceiling fan of any make with set of screws complete all as specified and directed .
Disconnecting & taking out unserviceable one and replacemet with new down rod for ceiling fan with 15mm dia (of length not less than 90cm and not more than 120cm) with hanging clamps for ceiling fan complete all as specified and directed.
Supply and fix down rod for ceiling fan with 15mm dia (of length not less than 180cm and not more than 210cm) with hanging clamps for ceiling fan complete all as specified and directed.
M&L painting the ceiling fan 1200mm /1400 mm sweep with one coat of syntetic enamel paint as existing colour and writing the MES No- as directed by Engr in Charge. Note:- (i)Painting of ceiling fan shall be done inside MES complex only. (ii) Taking down and re hanging of fan shall be measured and paid under relevent item here in above seperately.
Material and labour for winding of ceiling fan motor 1200 mm sweep of any make with super enameled copper winding wire of existing gauge (wt of copper winding wire per fan 350 to 500 gms) including cutting and getting out old burnt winding, sleeve work, varnishing with E class insulation varnish, threading, connections with twin core copper flexible wire of size 0.0076mm of length not more than one meter with each fan complete all as specified and directed. Note :- Motor shall be wound with machine inside MES complex only.
Description all as per Sl item No 26 here in above but ceiling fan of 1400 mm sweep
Disconnecting & taking out unserviceable one and replacemet with new energy efficeint Ceiling fan 1200mm sweep, energy efficient ISI mark with 5 star rating 230 Volts AC 50 Hz, single phase including provision of fixing arrangement, nut and bolt and flexible 3 core of size 1.5 sqmm not less than 0.5 m long complete including taking down existing one, writing MES No with synthetic enamel paint all as specified and as directed. Note:- (a) The contractor shall given a written guarantee of minimum two years from completion of work. (b) Old Unserviceable ceiling fan shall be deposited to MES store yard.
Taking down of exhuast fan any size/capacity after disconnecting cable connection, and refixing same in original position after necessary repair/over hauling including replacement of parts of minor nature such as screws, lugs, insulation tape, nuts, bolts, washers etc after cleaning the metal surface, greasing/lubricant etc to make it functional and making connection by replacing PVC insulated unsheathed cable of copper conduct of size 1.5 Sqmm from ceiling rose/ connector fan (up to 0.50 Mtr length) and taking down defective parts are deemed to be inclusive in quoted rate all as specified and as directed.
Material and labour for winding of Exhuast fan 450 mm sweep of any make with super enameled copper winding wire of existing gauge (wt of copper winding wire per fan 250 to 500 gms) including cutting and getting out old burnt winding, sleeve work, varnishing with E class insulation varnish, threading, connections with twin core copper flexible wire of size 0.0076mm of length not more than one meter with each fan complete all as specified and directed. Note :- Motor shall be wound with machine inside MES complex only.
Description all as per Sl item No 30 here in above but 300 mm sweep
Description all as per Sl item No 30 here in above but 250/230/200 mm sweep
Disconnecting & taking out unserviceable one and replacemet with new fan bush of suitable size for exhaust fan of the any sweep
Disconnecting & taking out unserviceable one and replacemet with new metal louvers of suitable size for exhaust fan of the 450mm sweep
Disconnecting & taking out unserviceable one and replacemet with new fan bearing of suitable size for exhaust fan of 450mm sweep including greasing.
Disconnecting & taking out unserviceable one and replacemet with new metal louvers of suitable size for exhaust fan of the 300mm sweep
Disconnecting & taking out unserviceable one and replacemet with new fan bearing of suitable size for exhaust fan of 300mm sweep including greasing.
Disconnecting & taking out unserviceable one and replacemet with new metal louvers of suitable size for exhaust fan of the 250/230/200mm sweep
Disconnecting & taking out unserviceable one and replacemet with new fan bearing of suitable size for exhaust fan of 250/230/200mm sweep including greasing.
M&L painting the exhaust fan of 450mm sweep with one coat of syntetic enamel paint as exiting colour and writing the MES No and return to MES storeyard /user unit from the work shop .as directed by Engr in Charge. Note:- Painting of ceiling fan shall be done inside MES complex only.
All as per item No 40 above but 300 mm sweep
All as per item No 40 above but 250/230/200 mm sweep
Disconnecting & taking out unserviceable one and replacemet with new Exhaust fan 200 mm sweep 230 volt square type, heavy duty with louvers of PVC body including necessary nut, bolts / screws including taking down existing one writing MES No with synthetic enamel paint all specified and directed. Note:- Old Unserviceable Exhaust fan shall be deposited to MES store yard.
M&L for winding of pedastal fan of 630 mm sweep of any make, cleaning the slots with super enameled copper winding wire of existing gauge (wt of copper winding wire per fan 350 to 500 gms) including cutting and getting out old burnt winding, sleeve work, varnishing with E class insulation varnish, threading, connections with twin core copper flexible wire of size 0.0076mm of length not more than one meter with each fan complete all as specified and directed. Note :- Motor shall be wound with machine inside MES complex only.
Description all as per Sl item No 44 here in above but 450 mm sweep
Description all as per Sl item No 44 here in above but 400 mm sweep
Disconnecting & taking out unserviceable one and replacemet with new fan bush of suitable size for peadstal fan of any sweep
Disconnecting & taking out unserviceable one and replacemet with new fan bearing of suitable size for peadstal fan of 630 mm sweep
M&L painting the pedastal fan of 630 mm sweep with one coat of syntetic enamel paint as exiting colour and writing the MES No and return to MES storeyard /user unit from the work shop as directed by Engr in Charge.
Description all as per Sl item No 49 here in above but 450 mm sweep
Description all as per Sl item No 49 here in above but 400 mm sweep
Taking down of wall mounted fan any size/capacity after disconnecting cable connection, and refixing same in original position after necessary repair/over hauling . (Note:- Repair, rewinding, over hauling and materials to be replaced are measured seperately.)
Disconnecting & taking out unserviceable one and replacemet with new fan bearing of suitable size for wall mounted fan of 400 mm sweep.
Disconnecting & taking out unserviceable one and replacemet with new bush of suitable size for wall mounted fan of the any sweep
Material and labour for winding of wall mounted fan 630 mm sweep of any make with super enameled copper winding wire of existing gauge (wt of copper winding wire per fan 350 to 500 gms) including cutting and getting out old burnt winding, sleeve work, varnishing with E class insulation varnish, threading, connections with twin core copper flexible wire of size 0.0076mm of length not more than one meter with each fan complete all as specified and directed. Note :- Motor shall be wound with machine inside MES complex only.
Description all as per Sl item No 56 here in above but 400 mm sweep
Disconnecting & taking out unserviceable one and replacemet with new wall mounted fan 300 mm sweep, power input 55 watt, 1380 RPM, air delivery-75 CMM, single phase 230 volts high performance motor with over heat protection world class styling & finish, facility to control wind & nature mode, aerodynamically designed balanced AS blades including fixing arrangement on wall including taking down existing one writing MES No with synthetic enamel paint all as specified and directed. Note:- Old Unserviceable wall mounted fan shall be deposited to MES store yard.
Excavating in trenches not exceeding 1.5 m wide and not exceeding 1.5m deep in soft/loose soil and getting out for taking down/laying of pipes complete all as specified and directed.
Returning, refilling including spreading levelling watering and well ramming in layers not exceeding 25cms thick in hard/dense soil complete all as specified and directed.
Removing excavated materials not exceeding 50m distance and depositing where directed at level not exceeding 1.5 m above the starting point complete all as specified and directed.
Riddling Sand obtained from excavation for cable protection 8cm under the cable and 15cm above the cable in trench and get the thick layer of 18cm after ramming complete all as specified and directed. Note :- In case sufficient sand not obtained from excavation, the quoted rate is deemed to be inclusive for the required additional qty obtain from out side MD land as directed by the Engineer-in-Charge.
M&L Fly ash bricks using modular bricks as in cable protection cover including taking down existing bricks of any size complete all as specified and directed.
Supply and lay XLPE insulated,screened ,PVC Bedded, galvanised steel strip of wire armoured, electric power cable heavy duty with aluminium condutor, multi strand, 1100Volts grade cross sectional area 6 Sqmm 2 core laid in trenches /ducts/fixed to wall/pole/ inside panel/ drawn through pipe including cable glands and terminal sockets etc including taking down existing cable all as specified and directed.
Supply and lay XLPE insulated,screened ,PVC Bedded, galvanised steel strip of wire armoured, electric power cable heavy duty with aluminium condutor, multi strand, 1100Volts grade cross sectional area 10 Sqmm 2 core laid in trenches /ducts/fixed to wall/pole/ inside panel/ drawn through pipe including cable glands and terminal sockets etc including taking down existing cable all as specified and directed.
Supply and lay XLPE insulated,screened ,PVC Bedded, galvanised steel strip of wire armoured, electric power cable heavy duty with aluminium condutor, multi strand, 1100Volts grade cross sectional area 10 Sqmm 4 core laid in trenches /ducts/fixed to wall/pole/ inside panel/ drawn through pipe including cable glands and terminal sockets etc including taking down existing cable all as specified and directed.
Supply and lay XLPE insulated,screened ,PVC Bedded, galvanised steel strip of wire armoured, electric power cable heavy duty with aluminium condutor, multi strand, 1100Volts grade cross sectional area 16 Sqmm 4 core laid in trenches /ducts/fixed to wall/pole/ inside panel/ drawn through pipe including cable glands and terminal sockets etc including taking down existing cable all as specified and directed.
Supply and lay XLPE insulated,screened ,PVC Bedded, galvanised steel strip of wire armoured, electric power cable heavy duty with aluminium condutor, multi strand, 1100Volts grade cross sectional area 25 Sqmm 4 core laid in trenches /ducts/fixed to wall/pole/ inside panel/ drawn through pipe including cable glands and terminal sockets etc including taking down existing cable all as specified and directed.
Disconnecting & taking out unserviceable one and replacemet with new switch piano flush type 5/6 Amps 240 volts single pole one way complete all as specified and directed.
Disconnecting & taking out unserviceable one and replacemet with new switch piano flush type 5/6 Amps 240 volts single pole two way complete all as specified and directed.
All as per item No 69 here-in-before but 15/16 Amp
Disconnecting & taking out unserviceable one and replacemet with new switch socket combination out let 3 pin 5/6 amps, flush type complete all as specified and directed..
Disconnecting & taking out unserviceable one and replacemet with new switch socket combination out let 5 in 1, 5 pin 5 and 15 amps, flush type complete all as specified and directed..
Disconnecting & taking out unserviceable one and replacemet with new Ceiling rose 3 plates flush type 6 Amps,250 volts AC ISI marked complete all as specified and directed.,
Disconnecting & taking out unserviceable one and replacemet with new lamp holder, insulated body, cord grip pattern SP 230 volt, complete all as specified and as directed.
Disconnecting & taking out unserviceable one and replacemet with new electronic fan regulator 230 volts, step type socket type, hum free 100/240 watt complete all as specified and directed.
Disconnecting & taking out unserviceable one and replacemet with new PVC gang box 1 way 05 amp complete all as specified and directed.
Disconnecting & taking out unserviceable one and replacemet with new PVC insulated and FRLS PVC Round Sheathed, Copper Conductor (flexible) industrial cable, 1100 Volt, 1.5 sqmm of 3 core complete all as spcified and directed.
Disconnecting & taking out unserviceable one and replacemet with new PVC insulated and FRLS PVC Round Sheathed, Copper Conductor (flexible) industrial cable, 1100 Volt, 2.5 sqmm 3 core complete all as spcified and directed.
Disconnecting & taking out unserviceable one and replacemet with new PVC insulated and FRLS PVC Round Sheathed, Copper Conductor (flexible) industrial cable, 1100 Volt, 4 sqmm of 3 core complete all as spcified and directed.
Disconnecting & taking out unserviceable one and replacemet with new PVC insulated and FRLS PVC Round Sheathed, Copper Conductor (flexible) industrial cable, 1100 Volt, 6 sqmm 3 core complete all as spcified and directed.
Disconnecting & taking out unserviceable one and replacemet with new single pole MCB 6 to 32 Amps, 240 v, 50 Hz AC suitable for ‘C’ curve, 10 KA breaking capacity conforming to IS 8828 of 1996 complete all as specified and directed.
Disconnecting & taking out unserviceable one and replacemet with new electric bell, AC 230 volt, single pole Ding Dong type complete all as specified and directed.
Disconnecting & taking out unserviceable one and replacemet with new LED bulb (Green colour) 15Watt B22 holder based complete all as specified and directed.
Disconnecting & taking out unserviceable one and replacemet with new energy saving lamps 2W/3W/5W SUODI LIGHTING day light spiral type complete all as specified and directed..
Disconnecting & taking out unserviceable one and replacemet with new small thread LED bulb 05 watt, warm white E-14, 2700K as per sample complete all as specified and directed.
Disconnecting & taking out unserviceable one and replacemet with new big thread LED bulb 05 watt, warm white E-27, 2700K as per sample complete all as specified and directed.
Disconnecting & taking out unserviceable one and replacemet with new 7 watt LED lamp complete all as specified and directed.
Disconnecting & taking out unserviceable one and replacemet with new 2.5 mfd condensor for ceiling fan complete all as specified and directed.
Disconnecting & taking out unserviceable one and replacemet with new plug top 3 pin 15 amps AC 230 volts complete all as specified and directed.
Disconnecting & taking out unserviceable one and replacemet with new plug top 3 pin 5 amps AC 230 volts complete all as specified and directed.
Disconnecting & taking out unserviceable one and replacemet with new bakelite sheet not less than 3 mm thick of size 100 x 100 mm complete all as specified and as directed.
Disconnecting & taking out unserviceable one and replacemet with new TP, MCB 40 to 63 amp, 240 v, 50 Hz AC suitable for ‘C’ curve, 10 KA breaking capacity complete conforming to IS 8828 of 1996 complete all as specified and directed.
Disconnecting & taking out unserviceable one and replacemet with new TPN, MCB 20 to 32 amp, 240 v, 50 Hz AC suitable for ‘C’ curve, 10 KA breaking capacity complete conforming to IS 8828 of 1996 complete all as specified and directed. .
Disconnecting & taking out unserviceable one and replacemet with new electronic fan regulator modular type 230 volts, step type socket type, hum free complete all as specified and directed.
Supply only insulation tape 25 mm width 10m long complete all as specified and directed.
Disconnecting & taking out unserviceable one and replacemet with new electronic LED driver 36W suitable for 2' x 2' ceiling light indoor fitting complete all as specified and directed.
Disconnecting & taking out unserviceable one and replacemet with new 4' 20W/ 18W LED tube rod suitable for existing fitting complete all as specified and directed.
Disconnecting & taking out unserviceable one and replacemet with new bell push complete all as specified and directed.
Disconnecting & taking out unserviceable one and replacemet with new PVC gang box 2 way 15 amp complete all as specified and directed.
Disconnecting & taking out unserviceable one and replacemet with new bakelite sheet not less than 3 mm thick of size 200 x 250mm complete all as specified and as directed.
Disconnecting & taking out unserviceable one and replacemet with new bakelite sheet not less than 3 mm thick of size 250 x 300mm complete all as specified and as directed.
Disconnecting & taking out unserviceable one and replacemet with new 4 mfd condensor for ceiling fan complete all as specified and directed.
Disconnecting & taking out unserviceable one and replacemet with new modular switch 1 way 6 amp.1 module complete all as specified and directed.
Disconnecting & taking out unserviceable one and replacemet with new modular Socket, 6A - 2/3 pin combined 2 module complete all as specified and directed.
Disconnecting & taking out unserviceable one and replacemet with new modular switch 1 way 16 amp.1 module complete all as specified and directed.
Disconnecting & taking out unserviceable one and replacemet with new modular Socket, 16A - 3/5 pin combined 2 module complete all as specified and directed.
Disconnecting & taking out unserviceable one and replacemet with new modular white cover plate with frame,3 module complete all as specified and directed.
Disconnecting & taking out unserviceable one and replacemet with new modular white cover plate with frame,4 module complete all as specified and directed.
Disconnecting & taking out unserviceable one and replacemet with new modular white cover plate with frame,6 module complete all as specified and directed.
Disconnecting & taking out unserviceable one and replacemet with new rigid, non-matalic, PVC conduit pipe, ISI marked, 32 mm bore, including bends, saddles, accessories complete all as specified and as directed.
Disconnecting & taking out unserviceable one and replacemet with new rigid, non-matalic, PVC conduit pipe, ISI marked, 25 mm bore, including bends, saddles, accessories complete all as specified and as directed.
Disconnecting & taking out unserviceable one and replacemet with newswitch socket combination outlet 3 in 1/ 3 pin 3 and 5 amps flush type with box complete all as specified and as directed.
Disconnecting & taking out unserviceable one and replacemet with new switch socket combination outlet 5 in 1/ 5 pin 5 and 15 amps flush type with box complete all as specified and as directed.
Disconnecting & taking out unserviceable one and replacemet with new electronic fan regulator 230 volts, step type, switch type, hum free complete all as specified and as directed.
Disconnecting & taking out unserviceable one and replacemet with new Double pole MCB 40 amp, 240 v, 50 Hz AC suitable for ‘C’ curve, 10 KA breaking capacity complete conforming to IS 8828 of 1996 complete all as specified and as directed.
Disconnecting & taking out unserviceable one and replacemet with new PVC batten of 15 mm (width) complete all as specified and directed.
Disconnecting & taking out unserviceable one and replacemet with new PVC batten of 20 mm (width) complete all as specified and directed.
Disconnecting & taking out unserviceable one and replacemet with new PVC batten of 25 mm (width) complete all as specified and directed.
Disconnecting & taking out unserviceable one and replacemet with new TPN, MCB 40 to 63 amp, 240 v, 50 Hz AC suitable for ‘C’ curve, 10 KA breaking capacity complete conforming to IS 8828 of 1996 complete all as specified and directed.
Disconnecting & taking out unserviceable one and replacemet with new 9 watt LED lamp complete all as specified and directed.
Disconnecting & taking out unserviceable one and replacemet with new PVC gang box 2 way 05 amp complete all as specified and directed.
Disconnecting & taking out unserviceable one and replacemet with new bakelite sheet not less than 3 mm thick of size 175 x 100mm complete all as specified and as directed.
Disconnecting & taking out unserviceable one and replacemet with new bakelite sheet not less than 3 mm thick of size 200 x 200mm complete all as specified and as directed.
Disconnecting & taking out unserviceable one and replacemet with new convetional type post top fitting with LED Post tops lamp fitting 1x45 W LED made die cast aluminium with innovative glare free indirect lighting ditribution & IP 65 protection inlcuding fixing arrangement with suitable flanged GI pipe base and PCC fixed on floor/ground complete all as specified and as directed.
Disconnecting & taking out unserviceable one and replacemet with new18 watt recess mounted sleek square down lighter enviornment friendly, new generation, energy saving with high power LED as light sources & clear glass inlcuding accessories all as specified and directed by Engr-in-Charge.
Disconnecting & taking out unserviceable one and replacemet with new factory made powder coated distribution board VTPN, 8 way double door including bus bar, Neutral bar, standard DIN rail, earth bar complete including taking down UNSV DB all as specified and conforming to IS: 8623 complete all as specified and as directed.
Disconnecting & taking out unserviceable one and replacemet with new factory made powder coated distribution board VTPN, 4 way double door including bus bar, Neutral bar, standard DIN rail, earth bar complete including taking down UNSV DB all as specified and conforming to IS: 8623 complete all as specified and as directed.
Disconnecting & taking out unserviceable one and replacemet with new factory made powder coated distribution board TPN, 4 way double door including bus bar, Neutral bar, standard DIN rail, earth bar complete including taking down UNSV DB all as specified and conforming to IS: 8623 complete all as specified and as directed.
Disconnecting & taking out unserviceable one and replacemet with new factory made powder coated distribution board SP & N 8 way double door, including bus bar, Neutral bar, standard DIN rail, earth bar complete all as specified and conforming to IS: 8623 complete all as specified and directed.
Disconnecting & taking out unserviceable one and replacemet with new factory made powder coated distribution board TPN, 4 way single door including bus bar, Neutral bar, standard DIN rail, earth bar complete all as specified and conforming to IS: 8623 complete all as specified and directed
Supply and fix in repair of convetional type boolard fitting with LED bollard light fittings suitable for 1x9 watt LED bollard in rectangular shaped vicotria design with opal acrylic diffuser and IP 65 protection inlcuding fixing arrangement with suitable flanged GI pipe base and PCC fixed on floor/ground complete all as specified and directed
Disconnecting & taking out unserviceable one and replacemet with new MCCB four pole, 100 Amp ultimate breaking capacity 16 KA complete conforming to IEC -61439-1 complete all as specified and directed
Disconnecting & taking out unserviceable one and replacemet with new LED bulk head luminarie fittings in engineering plastic housing with clear prismatic /opal diffuser /pressure aluminium die cast housing in white powder coating minimum IP-65 protection, system wattage not more than 10 watt (lumen output not less than 800 lumen) power factor more than 0.9, with surge protection device minimum 2KV, colour temperature not less than 5700K, LED driver with constant output voltage and current at input voltage of 140 Volt to 285 Volt AC at 50 Hz, glarefree, 0 UV radiation light fitting with wall mounting arrangement and making connections with PVC insulated copper conductor 3 core cable of 0.5 sqmm complete all as specified and directed.
M&L for Sub main wiring with PVC insulated unsheathed FRLS cable 1100 volts grade multi stranded copper conductor cable 2 runs of 4 sqmm drawn through in and incl suitable size PVC casing capping and all accessories fixed to wall/floors along with 4 sqmm PVC insulated unsheathed copper conductor multi stranded cable 1100V grade as earth continuity conductor and connected to common earth dolly including taking down existing sub main wiring of any size complete all as specified and as directed. Note:- (a) 2 runs of 4 sqmm cable along with one run of 4 sqmm cable for earth conductor and one run of PVC casing capping shall be measured as one length. (b) Connections of cables with MCBs or bus bars shall be done through appropriate size brass/copper thimbles.
M&L for sub main wiring with PVC insulated unsheathed FRLS cable 1100 volts grade multi stranded copper conductor cable 2 runs of 6 sqmm drawn through in and incl suitable size PVC casing capping and all accessories fixed to wall/floors along with 6 sqmm PVC insulated unsheathed copper conductor multi stranded cable 1100V grade as earth continuity conductor and connected to common earth dolly including taking down existing sub main wiring of any size complete all as specified and as directed. Note:- (a) 2 runs of 6 sqmm cable along with one run of 6 sqmm cable for earth conductor and one run of PVC casing capping shall be measured as one length. (b) Connections of cables with MCBs or bus bars shall be done through appropriate size brass/copper thimbles.
M&L Sub main wiring with PVC insulated unsheathed FRLS cable 1100 volts grade multi stranded copper conductor cable 4 runs of 10 sqmm drawn through in and incl suitable size PVC casing capping and all accessories fixed to wall/floors along with two runs of 10 sqmm PVC insulated unsheathed copper conductor multi stranded cable 1100V grade as earth continuity conductor and connected to common earth dolly including taking down existing sub main wiring complete all as specified and as directed. Note:- (a) 4 runs of 10 sqmm cable along with two runs of 10 sqmm cable for earth conductor and one run of PVC Casing capping shall be measured as one length. (b) Connections of cables with MCBs or bus bars shall be done through appropriate size brass/copper thimbles.
M&L Sub main wiring with PVC insulated unsheathed FRLS cable 1100 volts grade multi stranded copper conductor cable 4 runs of 10 sqmm drawn through in and incl suitable size non metalic PVC conduit and all accessories fixed to wall/floors along with two runs of 10 sqmm PVC insulated unsheathed copper conductor multi stranded cable 1100V grade as earth continuity conductor and connected to common earth dolly including taking down existing sub main wiring complete all as specified and as directed. Note:- (a) 4 runs of 10 sqmm cable along with two runs of 10 sqmm cable for earth conductor and one run of PVC Conduit shall be measured as one length. (b) Connections of cables with MCBs or bus bars shall be done through appropriate size brass/copper thimbles.
M&L for wiring for circuit complete submain wiring with 2 X1.5 sqmm single core PVC insulated, unsheathed FRLS 100 Volt grade multi stranded copper conductor cable drawn through and incl suitable dia rigid PVC conduit and accessories complete fixed surface to wall/roof/ceiling etc and incl 1.5 sqmm single core wire PVC insulated, unsheathed FRLS 1100v grade multi stranded copper conductor cable as earth continuity conductor etc including taking down existing sub main wiring of any size complete all as specified and directed Note:- (a) 2 runs of 1.5 sqmm cable along with one run of 1.5 sqmm cable for earth conductor and one run of PVC conduit shall be measured as one length. (b) Connections of cables with MCBs or bus bars shall be done through appropriate size brass/copper thimbles.
M&L for Sub main wiring with PVC insulated unsheathed FRLS cable 1100 volts grade multi stranded copper conductor cable 2 runs of 4 sqmm drawn through in and incl suitable size PVC Conduit and all accessories fixed to wall/floors along with 4 sqmm PVC insulated unsheathed copper conductor multi stranded cable 1100V grade as earth continuity conductor and connected to common earth dolly including taking down existing sub main wiring of any size complete all as specified and directed. Note:- (a) 2 runs of 4 sqmm cable along with one run of 4 sqmm cable for earth conductor and PVC conduit shall be measured as one length. (b) Connections of cables with MCBs or bus bars shall be done through appropriate size brass/copper thimbles.
M&L for sub main wiring with PVC insulated unsheathed FRLS cable 1100 volts grade multi stranded copper conductor cable 2 runs of 6 sqmm drawn through in and incl suitable size PVC conduit and all accessories fixed to wall/floors along with 6 sqmm PVC insulated unsheathed copper conductor multi stranded cable 1100V grade as earth continuity conductor and connected to common earth dolly including taking down existing sub main wiring of any size complete all as specified and directed. Note:- (a) 2 runs of 6 sqmm cable along with one run of 6 sqmm cable for earth conductor and one run of PVC conduit shall be measured as one length. (b) Connections of cables with MCBs or bus bars shall be done through appropriate size brass/copper thimbles.
M&L for Sub main wiring with PVC insulated unsheathed FRLS cable 1100 volts grade multi stranded copper conductor cable 2 runs of 4 sqmm drawn through in and incl suitable size steel conduit and all accessories fixed to wall/floors along with 4 sqmm PVC insulated unsheathed copper conductor multi stranded cable 1100V grade as earth continuity conductor and connected to common earth dolly including taking down existing sub main wiring of any size complete all as specified and directed. Note:- (a) 2 runs of 4 sqmm cable along with one run of 4 sqmm cable for earth conductor and one run of steel conduit shall be measured as one length. (b) Connections of cables with MCBs or bus bars shall be done through appropriate size brass/copper thimbles.
M&L for sub main wiring with PVC insulated unsheathed FRLS cable 1100 volts grade multi stranded copper conductor cable 2 runs of 6 sqmm drawn through in and incl suitable size steel conduit and all accessories fixed to wall/floors along with 6 sqmm PVC insulated unsheathed copper conductor multi stranded cable 1100V grade as earth continuity conductor and connected to common earth dolly including taking down existing sub main wiring of any size complete all as specified and directed. Note:- (a) 2 runs of 6 sqmm cable along with one run of 6 sqmm cable for earth conductor and one run of steel conduit shall be measured as one length. (b) Connections of cables with MCBs or bus bars shall be done through appropriate size brass/copper thimbles.
M&L for sub main wiring with PVC insulated unsheathed FRLS 1100 volts grade multi stranded copper conductor cable 4 runs of 6 sqmm drawn through in and incl suitable size PVC casing capping and all accessories fixed to wall/floors along with 1 runs of 6 sqmm PVC insulated unsheathed copper conductor multi stranded cable 1100V grade as earth continuity conductor and connected to common earth dolly including taking down existing sub main wiring of any size complete all as specified and directed. Note:- (a) 4 runs of 6 sqmm cable along with 1 runs of 6 sqmm cable for earth conductor and one run of PVC casing capping shall be measured as one length. (b) Connections of cables with MCBs or bus bars shall be done through appropriate size brass/copper thimbles.
Disconnecting & taking out unserviceable one and replacemet with new factory made powder coated distribution board SP & N 4 way double door, including bus bar, Neutral bar, standard DIN rail, earth bar and conforming to IS: 8623 complete all as specified and directed.
Disconnecting & taking out unserviceable one and replacemet with new factory made powder coated distribution board SP & N 2 way single door, including bus bar, Neutral bar, standard DIN rail, earth bar complete and conforming to IS: 8623 complete all as specified and directed.
Disconnecting & taking out unserviceable one and replacemet with new MCCB four pole, 63 Amp ultimate breaking capacity 16 KA complete conforming to IEC -61439-1 complete all as specified and directed
Disconnecting & taking out unserviceable one and replacemet with new 5 watt LED lamp complete all as specified and directed.
Disconnecting & taking out unserviceable one and replacemet with new indoor decorative extruded aluminium anodised housing /CRCA sheet steel coated housing (suitably coated to improve resistance against corrosion) LED T8 batten type luminaire (LED batten shall be prewired box type) retrofit solution with and including replaceable retrofit cool day white LED tube rod with well designed aluminium heat sink /aluminium housing for excellent heat dissipation; 2 feet (appx) size, high efficiency electronic driver, system wattage 10 watt (lumen output not less than 1000 lumen), power factor more than 0.9, with surge protection device minimum 3KV, colour temperature not less than 5700K, LED driver with constant output voltage and current at input voltage of 140 Volt to 285 Volt AC at 50 Hz, CRI more than 80, glarefree, no UV radiation light fitting with wall mounting arrangement and making connections with PVC insulated copper conductor 3 core cable of 0.5 sqmm complete all as specified and directed.
Taking down aluminum/copper point wiring on & including hard wood battens, surface conduit and board/ blocks etc or through conduits for light, socket or power point, fan point complete (Taking down of fittings such as switches, sockets, bells, ceiling rose, holders , regulators, light fittings, MCB, lamps etc shall be measured and paid seperately) and making good the disturbed plaster surfaces of wall, floor, ceiling and painting 2 coat of white wash/distamber to meet the existing surface and removing materials and debris to reinstate the premise neat and clean complete all as specified and directed.
M&L point wiring using approved colour coding as per IS for one light/bell/buzzer point controlled by one switch or one fan point controlled by one switch & fan regulator with PVC insulated, unsheathed FRLS multi stranded copper conductor 1.5 sqmm (nominal area) 1100 volt grade ISI 694 marked cable for phase & neutral drawn through concealed PVC Conduit, ISI marked with and including new MS/ cast iron sunken boxes duly painted with two coats of anticorrosive paint over a coat of red oxide primer on surface in touch with wall and synthetic enamel paint over a coat of red oxide on other side, covered with 3mm thick plastic laminated sheet for mounting switches, regulators, sockets etc including 1.5 sqmm (nominal area) copper conductor PVC insulated, unsheathed, multi stranded FRLS cable as earth wire and connected to earth dolly complete all as specified and as directed.
One light point/fan/bell point controlled by one switch
All as per item No. 151 here in before but for one 3 pin socket out 5 amp on the same board
All as per item No. 151 here in before but for one switch socket outlet 3 pin 5 Amps on independent board
All as per Sl No 151 above but Wiring with 4 Sqmm copper multistranded unsheathed cable and 4 Sqmm copper cable for earth continuity conductor controlled by one 15A switch socket independently
M&L point wiring using approved colour coding as per IS for one light/bell/buzzer point controlled by one switch or one fan point controlled by one switch & fan regulator with PVC insulated, unsheathed FRLS multi stranded copper conductor 1.5 sqmm (nominal area) 1100 volt grade cable for phase & neutral drawn through PVC casing Caping with and including new MS/ cast iron sunken boxes duly painted with two coats of anticorrosive paint over a coat of red oxide primer on surface in touch with wall and synthetic enamel paint over a coat of red oxide on other side, covered with 3mm thick plastic laminated sheet for mounting switches, regulators, sockets etc including 1.5 sqmm (nominal area) copper conductor PVC insulated, unsheathed, multi stranded FRLS cable as earth wire and connected to earth dolly complete all as specified and as directed.
One light point/fan/bell point controlled by one switch
All as per item No. 155 here in before but for One 3 pin socket out 5 amp on the same board
All as per item No. 155 here in before but for one switch socket outlet 3 pin 5 Amps on independent board
All as per Sl No 155 above but Wiring with 4 Sqmm copper multistranded unsheathed cable and 4 Sqmm copper cable for earth continuity conductor controlled by one 15A switch socket independently
M&L point wiring using approved colour coding as per IS for one light/bell/buzzer point controlled by one switch or one fan point controlled by one switch & fan regulator with PVC insulated, unsheathed FRLS multi stranded copper conductor 1.5 sqmm (nominal area) 1100 volt grade cable for phase & neutral drawn through medium grade open Steel conduit with and including new MS/ cast iron sunken boxes duly painted with two coats of anticorrosive paint over a coat of red oxide primer on surface in touch with wall and synthetic enamel paint over a coat of red oxide on other side, covered with 3mm thick plastic laminated sheet for mounting switches, regulators, sockets etc including 1.5 sqmm (nominal area) copper conductor PVC insulated, unsheathed, multi stranded FRLS cable as earth wire and connected to earth dolly complete all as specified and as directed. Note: (Switches, sockets outlets, blanking plate, Light fittngs, fans, bells & regulators will be measured and paid for separetely).
One light point/fan/bell point controlled by one switch
All as per item No. 160 here in before but for One switch socket outlet 3 pin 5 Amps on independent board
All as per Sl No 160 above but Wiring with 4 Sqmm copper multistranded unsheathed cable and 4 Sqmm copper cable for earth continuity conductor controlled by one 15A switch socket independently
Disconnecting & taking out unserviceable one and replacemet with new 4 feet 18/20 Watt LED light fitting batten type with Luminaries & integrated driver batten with lumen out not lessthan 110 lumens/watts & extruded polycorbanate housing square shaped diffuse suitable for mounting on wall/surface/ceiling 230 volts with extruded aluminium heat sink provided for efficient heat dissipation,permisible limit of CRI range,with recommended burning hours,4000K/5700k/6500K etc complete with all accessories internally pre wired and necessary mounting arrangements, including provision of new 3 core multistranded copper conductor of size 23/0.193 from ceiling rose to fitting including taking down old unserviceable fittings any type complete all as specified and as directed .
Disconnecting & taking out unserviceable one and replacemet with new shuttered socket outlet 3 pin 5/6 amps, flush type complete all as specified and directed
Disconnecting & taking out unserviceable one and replacemet with new shuttered socket outlet 2 in 1, 3 pin, 5/6 and15/16 amps complete all as specified and directed
Disconnecting & taking out unserviceable one and replacemet with new Surface & wall mounted LED fitting including 5 watt LED tube rod complete with all accessories internally, pre-wired, connecting up with twin core twisted flexiable copper conductor cable of suitable size complete all as specified and directed.
M&L for sub main wiring with PVC insulated unsheathed FRLS 1100 volts grade multi stranded copper conductor cable 4 runs of 4 sqmm drawn through in and incl suitable size PVC casing capping and all accessories fixed to wall/floors along with 1 runs of 4 sqmm PVC insulated unsheathed copper conductor multi stranded cable 1100V grade as earth continuity conductor and connected to common earth dolly including taking down existing sub main wiring of any size complete all as specified and directed. Note:- (a) 4 runs of 4 sqmm cable along with 1 runs of 4 sqmm cable for earth conductor and one run of PVC casing capping shall be measured as one length. (b) Connections of cables with MCBs or bus bars shall be done through appropriate size brass/copper thimbles.
Disconnecting & taking out unserviceable one and replacemet with new pathway light decorative retrofit LED fitting with 9 W LED bulb including necessary excavation, PCC foundation, 1.5 mtr long GI pipe light grade 50 mm bore with base plate, cable junction box with 2 pole connector 32 A capacity including cable entry and exist knockouts, 1.5 mtr length 3 core 1.5 sqmm PVC insulated copper round cable from connector to light fitting, disposal of soil to outside MD land including taking down existing one all as specified and directed by Engineer-in-Charge.
Disconnecting & taking out unserviceable one and replacemet with new 36 W LED recessed 2x2 luminaire with classic design & glare free soft illumination. Housing with white high reflection powder coated (RAL9016) CRCA sheet. Glare free, Opal diffuser for symmetrical light distribution fixed in separate CRCA sheet frame held in with housing by screws for easy maintenance. High efficiency long life LED package in integral module with lumen efficacy of >100 lm/w, viewing angle of 100° to ensure better uniformity. Powered by an independent Isolated, SELF Output electronic LED driver (SMPS based constant current supply) efficiency of 85% with built-in Surge protection 3Kv. System Lumen Output of 3000 lumens. CRI >80, Color temperature5700±300K, THD <10% and PF >0.95, IP20, IK02.Life class of 50,000 hrs @ L70, Operating Temperature: -10 TO +45 DEG.C; Input Supply Voltage Range:150-277 V, Frequency :50-60 HZ. Driver Safety requirement stds: IS 15885-2-13, Test Report to be submitted.
Disconnecting & taking out unserviceable one and replacemet with new building security luminaire of watt not less than 10 watt LED , not less than100 lumens/watt light High power LED, with unique peanut lens to ensure uniform distribution, higher spacing between poles and maintenance free system with excellent thermal management including prewired and all as specified and directed,
Disconnecting & taking out unserviceable one and replacemet with new building security luminaire of watt not less than 20 watt LED , not less than100 lumens/watt light High power LED, with unique peanut lens to ensure uniform distribution, higher spacing between poles and maintenance free system with excellent thermal management including prewired and all as specified and directed,
Disconnecting & taking out unserviceable one and replacemet with new electronic driver 10W suitable for bldg security light.
10W suitable for bldg security light of electronic driver 20W suitable for bldg security light.
Disconnecting & taking out unserviceable one and replacemet with new LED flood light 100 watt 230 V AC outdoor type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant complete with driver and lamp all as specified and directed.
Disconnecting & taking out unserviceable one and replacemet with new ALCOR LED flood light, 50 watts RGB colour changing light, 240 Volt, with high quality lenses & reflector, High grade aluminium pressure Die-Cast Housing with toughened glass cover, IP-66 class of protection, complete with control gear and all accessories including necessory PCC foundation for placing of flood light all as specified and directed.
Disconnecting & taking out unserviceable one and replacemet with new 9 watt surface mounted sleek square down lighter enviornment friendly, new generation, energy saving with high power LED as light sources & clear glass including accessories complete all as specified and as directed.
Disconnecting & taking out unserviceable one and replacemet with new industrial type metal clad plug top & socket single pole and a natural link earth enclosure with MCB SP 20 Amp complete all as specified and as directed.
Disconnecting & taking out unserviceable one and replacemet with new MCB SPN 32/40 amps 240 V complete all as specified and as directed.
M&L Earthing with Galvanised Earth Plate Electrode 600x600x 6mm thick burried directly in Ground (Earth Pit not less than 2.25 Metre below Ground Level) with Top edge of the Plate not less than 1.50 Metre below Ground Level, connected with Galvanised Earth Strip of size 25x6mm (upto 7.5m length) by means of Bolts, Nuts, Check Nuts and Washers of GI or Steel and connected Earthing Testing Point/Bus-bar including GI 40mm bore (dia) light grade Protection Pipe, Earth Plate surrounded by a packed thickness of Char Coal or Coke Dust mixed with Common Salt, Magneisum Sulphate (1 : 1 : 0.5) in alternate layers of not exc 150mm thick, PCC Pit in Cement Concrete 1:3:6 (20mm graded stone aggregate) and Pre-cast RCC Cover Slab of size 350x350x50 mm in Cement Concrete 1:2:4 (20mm graded stone aggregate), reinforced with 10mm dia TMT Bars @ 100mm Centre to Centre in both ways, GI Wire Mesh, Funnel with GI Watering Pipe 20mm bore (dia) medium grade including necessary Excavation in any type of soil, Returning, Filling in and Removal of surplus Spoil disposal to out side MD land and all as shown in Electrical Plate No. 3 of MES Schedule Part-I and Testing on Completion including taking down old unserviceable one, complete all as per specified and as directed.
Note for Item here in above :- (a) All Joints should be joined by Exothermic Welding or Brazing.
(b) After completion of work earthing shall be tested by the contractor in presence of Engineer-in-Charge, User and proper record shall be maintained duly signed by all concerned.
(c) Earth resistance tester shall be provided by the contractor. It should be caliberated from authorised company/ lab.
(d) After testing if desired earth resistance of less than 5 Ohm is not obtained, the earthing will be redone at no extra cost to Govt till desired result is obtained.
M&L in repairs Galvanised Earth strip of size 25 x 4 mm fixed on proper post insulator at the instrument end complete all as per specified and as directed.
Disconnecting & taking out unserviceable one and replacemet with new Switch flame proof rotary type with termination box in LM6, 16A, single pole 250V.
Disconnecting & taking out unserviceable one and replacemet with new LED light fitting 2x16 Watt flame proof, CMRI certified recommended for gas/ vapor group of IIA & IIIB, Zone 1 & 2 and IP 65 protection with die cast aluminum hosing with heat resistant toughened glass with LED tube light fixtures driver, holders, connector etc. Complete with all accessories prewired and including connecting up with three core flexible copper conductor cable with suitable size.
Disconnecting & taking out unserviceable one and replacemet with new switch flame proof switch socket and plug combined in LM6 cable termination box in LM6, 16A, 250V, 2P + earth,
Disconnecting & taking out unserviceable one and replacemet with new flame proof exhaust fan 300mm sweep 230 volts, with all accessories fixed on wall/ceiling including writing MES No with synthetic enamel paint all specified and directed. Make : Sudhir or equivalent in Bajaj, Baliga. Note:- Old Unserviceable flame proof exhaust fan hall be deposited to MES store yard.
S KUMARAN (BID ID -3446280)
T C KARUNANITHI (BID ID -3446310)
S.RAMACHANDRAN (BID ID -3446507)
LAKSHMI ELECTRICAL ENTERPRISES (BID ID -3446180)
M/s.Sai Agency (BID ID -3447961)
N SARAVANAN (BID ID -3446875)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .