Sh. Sudhir Kumar (Ex.Engg.Elect.)
Old Zonal MCD Office, Vishal Enclave, Rajouri Garden, West Zone.
Provision of Air Conditioners in OPD Rooms in Mata Gujri Hospital, Tilak Nagar.
2026_MCD_287865_1
E.E(Elect.)/WZ/2026-27/NIT No.44
Open Tender
Electrical Works
Percentage
60 days
EE/Electrical-III Division West Zone.
Please refer Tender documents.
3 documents required · 3 mandatory
₹590
₹30,000
17 Aug 2026
17 Aug 2026
24 Aug 2026
17 Aug 2026
24 Aug 2026
17 Aug 2026
This is a percentage-rate BOQ. The schedule below shows estimated quantities and rates. Bidders quote a single percentage above or below the total estimated cost.
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1.001 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required. 2 × 4 sq. mm + 1 × 4 sq. mm earth wire | 375 | metre | 476 | ₹1,78,500 |
| 1.002 | Supplying and fixing DP sheet steel enclosure on surface/ recess along with 25/32amps 240 volts C curve DP MCB complete with connections, testing and commissioning etc. as required. | 16 | each | 1,258 | ₹20,128 |
| 1.003 | Supplying , Installation, Testing and Commissioning of Air Cooled Hi Wall split type Air conditioners complete with Indoor unit(IDU), Out door unit (ODU), surface / concealed copper Refrigerant piping with insulation (closed cell elastomeric nitrile rubber tubular pipe section) upto 3 Mtr (IDU to ODU), copper power cable upto 3.5 Mtr (IDU to ODU) i/c drain pipe R-32/R-410/ R-407 Green Refrigerant, wireless Remote control, suitable for working between 180-260V with low & high voltage cutoff and 50 hz ,1 phase AC supply capable of performing cooling, dehumidification, air circulation of following capacity with Scroll / rotary compressor. The system shall be able to deliver 100% of the rated capacity upto 42 0C. Min 5 year Original Equipment Manufacturer (OEM) warranty both compressor and Printed Circuit Board (PCB). Must comply : Electrical cable IS 694 or IS 9968 temperature sensing control IS /International Electrotechnical Commission (IEC) 60730, hermetic compressor IS 10617, heat exchanger IS 11329, capacitor IS 2993 and motor IS 12615. Complete as per CPWD specification and IS : 1391 Part II 2023. The system shall be able to operate up to 50 0C (out door ambient temperature). Inverter Type - Cooling only 1.5 TR with 5 Star BEE Rating | 16 | Each | 43,539 | ₹6,96,624 |
| 1.004 | S/I/T/C of stand for split AC | 16 | each | 780 | ₹12,480 |
| 1.005 | S/I/T/C of copper pipe for split AC | 320 | m | 830 | ₹2,65,600 |
| 1.006 | S/I/T/C of Drain Pipe | 100 | m | 105 | ₹10,500 |
| 1.007 | S/I/T/C of 3 core, 4 sqmm. Electrical wire for air conditioner | 320 | metre | 156 | ₹49,920 |
| 1.008 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply and all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. Internal work - Exposed on wall. 25 mm nominal dia Pipes | 489 | metre | - | - |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.09 MB
4401ConditionsandCircular.pdf
Tender Documents • 10.69 MB
4401GCC.pdf
Tender Documents • 1.74 MB
4401DNIT.pdf
Tender Documents • 0.57 MB
4401Schedule.pdf
Tender Documents • 0.59 MB
BOQ_335817.xls
BOQ • 0.28 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at [email protected].