Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹17.3 LAccepted-AOC FIRDOUS ABAD BATMALOO SRINAGAR PIN 190004 J K | SRINAGAR | SRINAGAR | J K | 190004 | L1 | Accepted-AOC BEING L1. | |
| 2 | L2₹17.7 L+₹1,337.50 (0.08%)Rejected-Finance 29 IQBAL COLONY SONWAR SRINAGAR 190004 J K | SRINAGAR | SRINAGAR | JAMMU AND KASHMIR | 190004 | L2 | Rejected-Finance OTHER THAN L1. | |
| 3 | L3₹18.7 L+₹1.1 L (5.97%)Rejected-Finance | L3 | Rejected-Finance OTHER THAN L1. | |
| 4 | L4₹20.5 L+₹2.8 L (16.0%)Rejected-Finance | L4 | Rejected-Finance OTHER THAN L1. | |
| 5 | L5₹23.2 L+₹5.5 L (31.0%)Rejected-Finance | L5 | Rejected-Finance OTHER THAN L1. |
Tender Value
₹25 L
EMD Value
₹50,000
Closing Date
17 Jun 2022, 6:00 pmClosed
GE 864 EWS
GE 864 EWS BB CANTT SRINAGAR
REPAIR/ REPLACEMENT OF PERIMETER SECURITY LIGHT, STREET LIGHT AND HIGH MAST INCLUDING ALLIED WORKS UNDER AGE EM OF GE 864 EWS AT BB CANTT SRINAGAR.
2022_MES_525351_1
864/WS-11/2022-23
Open Tender
Miscellaneous Works
Item Rate
180 days
GE 864 EWS BB CANTT SRINAGAR
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
GE 864 EWS
₹50,000
Yes
28 Jul 2022
20 May 2022
20 Jun 2022
20 May 2022
17 Jun 2022
3 Jun 2022
Amount
Excavation in trenches not exc 1.5 mtr wide and not exc 1.5 mtr in depth for laying of cables/errection of pole etc n.exc 10 sqm on plan and n.exc 1.5 depth and getting out in hard/dense soil complete all as specified and as directed.
Ditto all as per srl item No. 1.00 described here-in-before but exc 1.5 mtr depth but not exc 3.0mtr depth
Returning, filling in trenches incl spreading leveling watering and well ramming in layers not exc 25 cm thick in each layer in soils complete as specified and as directed
Removing excavated material (soils) n exc. 50m and depositing where directed at a level n exc. 1.5 m above the starting point complete all as specified and as directed
M&L for sand cushioning with a layer of river sand 23 cm thick under and above the cable complete all as specified and as directed. Note : - Punned down thickness upto 18cm shall only be measured and paid.
S&L sub class burnt bricks for cable protection complete as specified as directed
M&L for PCC (1:4:8) type D2 (using 40mm graded crushed stone aggregate) as in foundations, filling and mass concrete complete as specified as directed
M&L for PCC (1:3:6) type C1 (using 20mm graded crushed stone aggregate) as in foundation of poles/stays incl necessary form work complete as specified as directed
S&L in replacement XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armouned power cables (heavy duty) with aluminium conductor, 1100 volts grade, cross sectional area 10 Sqmm, 2 core laid in trenches complete as specified as directed.
S&L in XLPE replacement insulated, screened, PVC bedded, galvanised steel strip or wire armouned power cables (heavy duty) with aluminium conductor, 1100 volts grade, cross sectional area 10 Sqmm, 4 core laid in trenches complete as specified as directed
S&L in replacement XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armouned power cables (heavy duty) with aluminium conductor, 11000 volts grade, cross sectional area 16 Sqmm, 4 core laid in trenches complete as specified as directed
S&L in replacement XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armouned power cables (heavy duty) with aluminium conductor, 1100 volts sgrade, cross sectional area 50 Sqmm, 3.5 core laid in trenches complete as specified as directed
S&F in replacement GI pipe light grade 40 mm dia in trenches for cable protection/on pole/on wall complete all as specified and diretced.
S&F in replacement FRP cable looping boxes with PVC sheet finish inside including MCB SP 1 No, heavy duty PVC connector 4 way Terminal strip 01 No & fixed to pole with suitable size clamp with nuts, bolts complete as specified as directed
S&F in replacement street light panel 6 KW confirm to IS/ IES 60947-4-1 suitable for single phase MCB rating 40 Amps on /off timer Astronomical, conractor rating 63 Amp including internal wiring in built short circuit protection, IP-54 complete all as specified and directed.
S&F in replacement Bracket made out of GI tubing medium grade 40 mm bore, up to 90 cm long including MS clamps made out of MS flat iron 25 x 6 mm , nuts, bolts, washers etc and including before fixing applying two coats of aluminum paint over a coat of red oxide primer complete all as specified and directed.
S&F in replacement LED Street light fitting 70/72W, pressue die-cast aluminum complete fixing arragnement complete all as specified and directed.
S&F in replacement Flood light fitiing 120W LED energy saving environmental friendly long life exclusive innovative die cast aluminum IP 65 flood light with high power LEDs as light source suitable for highlighting architechtural features or retail spaces complete all fixing arrangement complete all as specified and diretced.
S&F in replacement post top lantern LED type 20W 230 volt AC outdoor type with decorative post top for 360 degree indirect light IP-65 protection with impact and corrosion resistant complete all fixing arrangement complete all as specified and diretced.
S&F in replacement LED solar street light fittings 12/16 watt including galvanized steel pole in built lithium ion battery, solar panel, charge cotroller with dusk down sensor complete (excavation and earth work shall be measured separately) type 20W 230 volt AC outdoor type with decorative post top for 360 degree indirect light IP-65 protection with impact and corrosion resistant complete all fixing arrangement complete all as specified and diretced.
S&F in replacement BOLLARD 9W/10W/12W new genertion energy saving environmental friendly long life aesthetically designed alumium landscape luminarie for diffused lighting with high power LED as light source complete including, PCC blocks directed by Engr-in-charge, GI pipe as required at site and connection etc complete all as specified and directed.
S&F in replacement of 2 runs of PVC insulated 1.5 sqmm single core multistranded aluminium conductor cable and one run of 1 sqmm copper wire as earth continuity conductor drawn through and incl rigid non metalic conduit 20 mm external dia fixed on poles & connecting up complete all as specified and diretced. Note: Two runs of cable and one run of earth wire and one run of conduit shall be measured as one length.
S&F in replacement landscape lights / garden light fittings elegent yet minimalstic design acts as silent observer and giving lights, diffuser at the upper portion acts as beacon of path guidence in a landscape environment suitable for 240 volts 50 Hz AC Supply of capacity 8 watt LED including making connections and construction of foundation of size 150mm x 150mm x 200mm with PCC (1:2:4) type B1 (using 20 mm graded crushed stone aggregate) and fixing PVC pipes suitable dia inside concrete for fixing of incomming and outgoing cables etc complete all as specified and directed.
S&F in replacement service cable 10 Sqmm twin core 1100 volts grade heavy duty cable PVC insulated aluminium standard conductor, served with inner sheathing of PVC tape and overall PVC sheathed in service connections twin core cable flat or circular fixed on poles / walls complete all as specified and as directed.
S&F in replacement service cable 6 Sqmm twin core 1100 volts grade heavy duty cable PVC insulated aluminium standard conductor, served with inner sheathing of PVC tape and overall PVC sheathed in service connections twin core cable flat or circular fiixed on poles / walls complete all as specified and as directed.
S&F in replacement Change over switch on load 4 pole 200 Amps complete fixing arrangement complete all as specified and diretced.
S&F in replacement Change over switch on load 4 pole 100 Amps complete fixing arrangement complete all as specified and diretced.
S&F in replacement Change over switch on load 4 pole 63 Amps complete fixing arrangement complete all as specified and diretced.
M&L for earthing complete with galvanized steel earth plate electrode 60 cm x 60 cm x 6mm thick buried directly in ground vertically to a depth not less than 2.5 mtr below ground level with top edge of earth plate at a depth not less than 1.5 mtr connected to and incl galvanized earth lead wire 4.0 mm dia up to 7.5 mtr long by means of nuts, bolts, thimbles, check nuts and washers etc made of galvanized iron connected to earthing test point all as shown in electrical plate No 3 of SSR Part-I 2009 and as specified or indicated and testing on completion incl earth work and excavation in any type of soil PCC (1:3:6) type C1 chamber, precast slab 40mm thick in cement concrete (1:2:4) type B1 with 8 mm dia MS bars reinforced at 10 cm centre to centre both ways incl funnel with watering pipe wire mesh and lugs, incl test point complete all as specified and as directed
S&F in replacement air break (switch) 11000 volts insulator triple pole mechanically operated mounted on insulator and steel frame with operating mechanism worked from ground level for current rating up to 200 Amps complete all as specified and diretced.
M&L for repair /replacement of following accessories in panel of high mast light:-
Indicating light in Green, Red , Yellow
Terminal block up to 6 way
Combined multimeter voltmeter and ammeter
Selctor switch
Timer On/Off
Contractor with control cable of 1.0 Sqmm copper cable multistanded unsherthed (FRLS)
Control gear box for fitting-09 Nos withWinch double drum type having operating speed and gear ratio as per manufacturer design working manually / electrically with stainless steel wire rope 6mm dia two point suspension system all as per manufacturer design-1 No.
Lantern carriage ring suitable for 9X120W capacity
Contactor 32 amps 4 pole
S&F in replacement bracket made out of GI tubing medium grade 25 mm bore 60 cm long including MS clamp made out of flat iron 25x10mm nuts, bolts, washer etc and including fixing applying two coats of aluminium paint over a red oxide primer complete all as specified and as directed
S&F in replacement LED lamp 30/40/50 watt capacity B-22 base complete all as specified and as directed
S&F in replacement LED Driver suitable for street light 30 watt to 45 watt capacity complete all as specified and as directed
S&F in replacement LED Driver suitable for street light 60 watt to 72 watt capacity complete all as specified and as directed
S&F in replacement LED Driver suitable for street light 90 watt to 120 watt capacity complete all as specified and as directed.
M/S TAHIRA ENTERPRISES
M/s Lal Enterprises
ALCO ENGINEERSPVT LTD
M/S S. D. BUILDERS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .