Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹23.4 CrAdmitted-Finance | ₹23.4 Cr | L1 | Admitted-Finance |
| 2 | L2₹23.4 CrAdmitted-Finance | ₹23.4 Cr | L2 | Admitted-Finance |
| 3 | Rejected-Technical | - | - | Rejected-Technical Technically non-responsive |
| 4 | Rejected-Technical | - | - | Rejected-Technical Technically non-responsive |
| 5 | Rejected-Technical DUMKA ROAD OPPOSITE IRRIGATION COLONY JAMTARA JHARKHAND 815351 | JAMTARA | JHARKHAND | 815351 | - | - | Rejected-Technical Technically non-responsive |
| Sl No | Description | Qty | Unit | Sanjay Sharan L1 | M/S SADANAND GUPTA L2 |
|---|---|---|---|---|---|
| 1.00DISMANTLING WORK | |||||
| 2.00 | Dismantling pucca brick or lime work including stacking serviceable materials in countable stacks within 15M. lead and disposal of unserviceable materials with all leads all complete as per direction of E/l. | 575.43 | m3 | 600 ₹3.5 L | 535.33 ₹3.1 L |
| 3.00 | Dismantling plain cement or lime concrete work including stacking serviceable materials in countable stacks within 15M. lead and disposal of unserviceable materials with all leads all complete as per direction of E/l. | 67.5 | m3 | 950 ₹64,125 | 944.7 ₹63,767.25 |
| 4.00 | Dismantling and purchase of reinforcement in R.C.C.work including stacking serviceable materials in countable stacks within 15M. lead and disposal of unserviceable materials with all leads all complete as per direction of E/l. | 500.84 | m3 | -212 -₹1,06,178.93 | -1,612.5 -₹8,07,610.95 |
| 5.00 | Dismantling patent stone floor including stacking serviceable materials in countable stacks within 15M. lead and disposal of unserviceable materials with all leads all complete as per direction of E/l. | 1,354 | m2 | 65 ₹88,010 | 40.27 ₹54,525.58 |
| 6.00 | Dismantling and purchase of steel material thached shed roof with ballies rafters, purlines etc. including stacking of serviceable materials in countable stacks within 15 M. lead and disposal of unserviceable materials with all leads as per direction of E/l. | 322.54 | m2 | -21.2 -₹6,837.85 | -21.5 -₹6,934.61 |
| 7.00 | Taking down old door and window shutters and purchase including stacking serviceable materials within 15M. lead and disposal of unserviceable materials with all leads all complete as per direciton of E/l. | 80 | Each | -37.1 -₹2,968 | -37.63 -₹3,010.40 |
| 8.00 | Taking down chowkhat in doors and purchase including stacking serviceable materials within 15M. lead and disposal of unserviceable materials with all leads all complete as per direciton of E/l. | 30 | Each | -212 -₹6,360 | -215 -₹6,450 |
| 9.00 | Taking down chowkhat in windows and purchase including stacking serviceable materials within 15M. lead and disposal of unserviceable materials with all leads all complete as per direciton of E/l. | 50 | Each | -212 -₹10,600 | -215 -₹10,750 |
| 10.00 | Disposal of moorum/building rubbish/ malba/ similar unserviceable, dismantled or waste material by mechanical transport including loading, transporting, unloading to approved municipal dumping ground for lead upto 10 km for all lifts, complete as per directions of Engineer-in-charge | 1,245.32 | m3 | 266.69 ₹3.3 L | 270.46 ₹3.4 L |
Tender Value
₹23.4 Cr
EMD Value
₹23.4 L
Closing Date
22 Nov 2021, 5:00 pmClosed
Project Director (Technical)
JUIDCO, 3rd Floor, Pragati Sadan, Kutchery Chowk, Ranchi - 834001
Construction of Hazaribag Municipal Building under Hazaribag Municipal Corporation, Hazaribagh District
2021_UDD_52645_1
JUIDCO/MB/HAZARIBAG/414/20-21
Open Tender
Civil Works - Buildings
730 days
Hazaribag
Please refer Tender documents.
5 documents required · 5 mandatory
₹25,000
Managing Director, JUIDCO Ltd.
₹23.4 L
29 Dec 2021
29 Oct 2021
23 Nov 2021
29 Oct 2021
22 Nov 2021
29 Oct 2021
Amount
DISMANTLING WORK
Dismantling pucca brick or lime work including stacking serviceable materials in countable stacks within 15M. lead and disposal of unserviceable materials with all leads all complete as per direction of E/l.
Dismantling plain cement or lime concrete work including stacking serviceable materials in countable stacks within 15M. lead and disposal of unserviceable materials with all leads all complete as per direction of E/l.
Dismantling and purchase of reinforcement in R.C.C.work including stacking serviceable materials in countable stacks within 15M. lead and disposal of unserviceable materials with all leads all complete as per direction of E/l.
Dismantling patent stone floor including stacking serviceable materials in countable stacks within 15M. lead and disposal of unserviceable materials with all leads all complete as per direction of E/l.
Dismantling and purchase of steel material thached shed roof with ballies rafters, purlines etc. including stacking of serviceable materials in countable stacks within 15 M. lead and disposal of unserviceable materials with all leads as per direction of E/l.
Taking down old door and window shutters and purchase including stacking serviceable materials within 15M. lead and disposal of unserviceable materials with all leads all complete as per direciton of E/l.
Taking down chowkhat in doors and purchase including stacking serviceable materials within 15M. lead and disposal of unserviceable materials with all leads all complete as per direciton of E/l.
Taking down chowkhat in windows and purchase including stacking serviceable materials within 15M. lead and disposal of unserviceable materials with all leads all complete as per direciton of E/l.
Disposal of moorum/building rubbish/ malba/ similar unserviceable, dismantled or waste material by mechanical transport including loading, transporting, unloading to approved municipal dumping ground for lead upto 10 km for all lifts, complete as per directions of Engineer-in-charge
Taking down C.A. or G.C.I. sheet in roof with ridges including stacking the serviceable material with 15M. lead and disposal of unserviceable materials with all leads as per direction of E/l.
Taking down C.A. or G.C.I. sheet in roof with ridges including stacking the serviceable material with 15M. lead and disposal of unserviceable materials with all leads as per direction of E/l.
BORING
HYDT: - Cost of Driling 200mmx165mmx125 mtr.deep bore well in all kind of Soil and rock in rural area for instalation of pump set with Hydrolic DTH Rig machine all complete including all materials, tools, driling rig, air compressure and equipments as well as fule, lubricants and cost of transportation of rig machine annd other vehical up to Site. (2 Nos.)
(a) From 0.00 M to 50.00 M below G.L.
(b) From 51.0 M to200.00 M
Supplying, assembling, lowering and fixing in vertical position in bore well, unplasticized PVC medium well casing (CM) pipe of required dia, conforming to IS: 12818, including required hire and labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer -in-charge. 200 mm nominal size dia UPVC.
Supplying all tools, equipments and labour and doing washing and flushing and development of drilled tube well to give clean and clear water all complete as per direction of E/I.
Supplying labour, cement and calcium cloride or bentonite solution and equipments for groutinf the casing pipe after lowering in the bore including carriage of material to work site etc.all complete as per specification and direction of E/I.
Providing and fixing M.S. clamp of required dia to the top of casing/ housing pipe of tubewell as per IS: 2800 (part I), including necessary bolts & nuts of required size complete. 200 mm clamp
Supplying 100mm dis submersible pump sets confirming to 8034 and motor confirming to IS 9283 pump shall be suitable for various delivery head and discharge with stainless steel pump shaft and polypropylene/noryl impeller. Motor suitable for working on 415 + 10, 3HP, 50 Hz, AC supply with cable guard, thurst carbon/fiber bearing to withstand entire hydraulic thurst, water proof winding shall be provided. The pump set shall be suitable for diret coupling Pump shall have suitable outlet as per manufacturers design. Anti thurst stream lined non return valve shall be provided with pump, 3 meter submersible copper conductor cable in single/double run shall be provided with each pump. Submersible pump set 100mm dia (with Polypropylene/Noryl Impeller) up to 20 stages - 5 HP
D.O.L starter with S.S Enclosure with 380/415 Volt coil as per IS 3914 - upto 5 HP.
3 crore PVC insulated, PVC sheathed copper conductor flat submersible cable- Supplying, Flat flexible submersible cable with, copper conductor, PVC insulated and PVC sheathed. 3 core 4 sqmm
Supplying and lowering 40 mm dia. Column PVC pipe with all complete job.
BUILDING WORK
Earth Work in excavation in Foundation Trenches in Ordinary soil (vide classification of soil item -B) and disposal of excavated earth as obtained to a distance upto 50 M including all lift, leveling ramming the foundation trenches, removing roots of tree shrubs all complete as per approved design, building specification and direction of E/I
Extra for earth work in hard soil as per specification & direction of engineer in charge (Vide classification of soil item B)
Extra rates for quantities of works, executed : In or under water and/or liquid mud, including pumping out water as required.
Earth filling in foundation trenches and plinth in layer not exceeding 150mm thick will watered rammed fully compacted and fine dressed with earth obtained from excavation of foundation trenched with a lead of 50mm and lift of 1.5M all complete as per building specification and direction of E/I. (Mode of measurement compacted volume).
Removal & disposal of surplus excavated earth by mechanical transport including loading unloading stacking and spreading at all lift and lead up to 13km to spoil dump approved by local authority.
Clearing jungle including uprooting of rank vegetation, grass, brush wood, trees and saplings of girth up to 30 cm measured at a height of 1 m above ground level and removal of rubbish up to a distance of 50 m outside the periphery of the area cleared.
Providing coarse clean local SAND IN FILLING in foundation trenches or in plinth including ramming and watering in layer not exceeding 150 mm thick with all leads and 1.5 M lifts including cost of all materials, labours, royalty and taxes all complete as per building specification and direction of Engineer In charge (Mode of measurement compacted volume)
Treatment of soil under existing floors using chemical emulsion @ one litre per hole, 300 mm apart including drilling 12 mm diaMTR.er holes and plugging with cement mortar 1:2 (1 cement : 2 Coarse sand) to match the existing floor With Chlorpyriphos/Lindane E.C. 20% with 1% concentration
water bond macadam: - Providing, laying spreading & compacting stone aggregates of specific size to water bond macadam specification including spreading in uniform thickness hand packing, rolling with vibratory roller 8-10 tone / smothery wheeled steel roller in stages to proper gate & chamber, applying and booming requisite type of screening / binding materials to fill up the interstices of course aggregate, water and compacting to the required density. (B) By mechanical means. (b) Using screening Type - A (13.2mm Agg.) with vibratory roller
Providing P.C.C. (1:3:6) in foundation (Plain cement concrete 1:3:6 nominal mix in foundation with crushed stone aggregate 40 mm nominal size mechanically mixed , placed in foundation and compacted by vibrating curing, for 14 days.)nas per building specification and direction of Engineer-in-charge.
Providing and laying in position ready mixed M-25 grade concrete for reinforced cement concrete work, using fly ash and cement content as per approved design mix, including pumping of R.M.C. from transit mixer to site of laying, excluding the cost of centering, shuttering, finishing and reinforcement, including cost of admixtures in recommended proportions as per IS : 9103 to accelerate / retard setting of concrete, improve workability without impairing strength and durability as per direction of the Engineer - in - charge. NOTE- (1) Cement content considered in this item is @ 330 kg/cum. Excess/ less cement used as per design mix is payable/ recoverable separately.
All works upto plinth level
All works above plinth level upto floor V level
Extra for R.C.C./ B.M.C/ R.M.C. work above floor V level for Each four floors or part thereof.
Add for using extra cement in the items of design mix over and above the specified cement content therein.
Centering and shuttering including strutting, propping etc. and removal of form for : Foundations, footings, bases of columns, etc. for mass concrete
Centering and shuttering including strutting, propping etc. and removal of form for Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc.
Centering and shuttering including strutting, propping etc. and removal of form for : Suspended floors, roofs, landings, balconies and access platform
Centering and shuttering including strutting, propping etc. and removal of form for Lintels, beams, plinth beams, girders, bressumers and cantilevers
Centering and shuttering including strutting, propping etc. and removal of form for :Columns, Pillars, Piers, Abutments, Posts and Struts
Centering and shuttering including strutting, propping etc. and removal of form for Stairs, (excluding landings) except spiral-staircases
Centering and shuttering including strutting, propping etc. and removal of form for : Cornices and mouldings
Centering and shuttering including strutting, propping etc. and removal of form for : Suspended floors, roofs, landings, balconies and access platform. with water proof ply 12 mm thick
Centering and shuttering including strutting, propping etc. and removal of form for : Arches, domes, vaults up to 6 m span
Extra for additional height in centering, shuttering where ever required with adequate bracing, propping etc., including cost of de-shuttering and decentering at all levels, over a height of 3.5 m, for every additional height of 1 MTR.re or part thereof (Plan area to be measured). Suspended floors, roofs, landing, beams and balconies (Plan area to be measured)
Add for plaster drip course/ groove in plastered surface or moulding to R.C.C. projections.
Providing Tor steel reinforcement of 8mm. dia. rods as per approved design and drawing excluding carriage of M.S. bars to work site , cutting, bending and binding with annealed wire with cost of wire, removal of rust placing the rods in position all complete as per building specification and direction of E/l. (TMT Fe 500 (only vailid for TATA (TISCON), SAIL, JSPL, Electro steel Limited Bokaro and Vizal steel(RINL))
Providing Tor steel reinforcement of 10mm. dia. rods as per approved design and drawing excluding carriage of M.S. bars to work site , cutting, bending and binding with annealed wire with cost of wire, removal of rust placing the rods in position all complete as per building specification and direction of E/l. (TMT Fe 500 (only vailid for TATA (TISCON), SAIL, JSPL, Electro steel Limited Bokaro and Vizal steel(RINL))
Providing Tor steel reinforcement of 12mm. to 32mm. dia. rods as per approved design and drawing excluding carriage of M.S. bars to work site , cutting, bending and binding with annealed wire with cost of wire, removal of rust placing the rods in position all complete as per building specification and direction of E/l. (TMT Fe 500 (only vailid for TATA (TISCON), SAIL, JSPL, Electro steel Limited Bokaro and Vizal steel(RINL))
Providing and fixing of Glass Fiber Reinforced Concrete (GFRC) Column in approved size, pattern, Design, thickness and color. The Column should be made From 53 grade white Portland cement/ 43 grade OPC or PPC gray cement manufactured by J.K. Cement or equivalent having minimum compressive Strength of 40N/mSQM, Quartz, Fine Silica Sand, Alkali Resistant Glass Fiber manufactured by Sant Gobain, Owens corning or equivalent, super plasticizers and polymers manufactured by BASF, Sika, MYK Schomburg or equivalent. The material casting should take place in Synthetic Rubber / FRP Mould manufactured by Reckli or equivalent. The Fixing of Column should be Dry Fixing i.e. to be done with Stainless Steel (SS-304)/ MS Frames, dash fasteners, Self-screw and pins. GFRC Column (35-40 mm thick) as per design with GFRC capitals. Note :- MS frame Structure for GFRC column to be provided as per design
Providing designation 100A brick work with flyash lime brick (FLAG) confirming to IS 12894-1990 (9"x425"x3") in C.M. (1:4) in foundation and plinth with approved quality of clean coarse sand of F.M. 2 to 2.5 including providing 10mm thick mortar joints costs of screening materials, raking out joints to 15mm depth curing taxes and royalty all complete as per building specification and direction of E/I.
Providing designation 100A brick work with flyash lime brick (FLAG) confirming to IS 12894-1990 (9"x4.5"x3") in C.M. (1:6) in super structure with approved quality of clean coarse sand of F.M. 2 to 2.5 including providing 10mm thick mortar joints costs of screening materials, scaffolding, raking out joints to 15mm depth curing taxes and royalty all complete as per building specification and direction of E/I.
Providing designation 112mm thick reinforced designation 100A brick work with flyash lime brick (FLAG) in (1:4) in superstructure with approved quality of clean coarse sand of F.M. 2 to 2.5 including the cost of screening carriage of materials, scaffolding, raking out joints to 15mm depth, curing, taxes and royalty (but excluding the cost of reinforcement) all complete as per building specification and direction of E/I.
Extra for brick work for each consecutive floor above first floor including watering & scaffolding all complete as per direction of E/I
Extra for providing & placing in position 2 no 6mm dia ms bar every 3rd corse of half brick masonary
Supplying, fitting and fixing good quality, well dressed and well seasoned Sal wood work in choukhat in doors, windows, skylights, fanlights and C/W celestial window openings, including wedge over all clamps complete includingapplicationof two coatsof wood preservativeof approved quality on the surface butting walls and lintels all completeas per building specificationand direction of E/I
Supplying, fitting and fixing 35mm thick solid core type decorative single leaf flush door shutter with one sides teak decorative and another side commercial veneered with black board core bended with high quality phenol formal dehydes synthetic resin of standard make with Aluminium fittings such as hinges, tower bolts, handle, cleats and sand blocks and taxes all complete as per building specification and direction of E/l.
Extra for providing lipping with 2nd class teak wood battens 25 mm minimum depth on all edges of flush door shutters (over all area of door shutter to be measured).
Extra for cutting rebate in flush door shutters (Total area of the shutter to be measured).
Providing and fixing wooden moulded beading to door and window frames with iron screws, plugs and priming coat on unexposed surface etc. complete : 50x12 mm
Providing, fitting and fixing oxidised iron fitting of approved quality and make to door and window all complete as per building specification and direction of E/I necessary screws etc. complete. 300 mm sliding door bolt
Providing and fixing bright finished brass 100 mm mortice latch and lock, ISI marked, with six levers and a pair of anodised (anodic coating not less than grade AC 10 as per IS : 1868) aluminium lever handles of approved quality with necessary screws etc. complete.
Providing and fixing bright finished 100 mm mortice lock with 6 levers without pair of handles of approved quality for aluminium door, with necessary screws etc complete as per direction of Engineerin-charge.
Providing and fixing aluminium hanging floor door stopper, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour and shade, with necessary screws etc. complete. Twin rubber stopper
Providing and fixing aluminium extruded section body tubular type universal hydraulic door closer (having brand logo with ISI, IS : 3564, embossed on the body, door weight upto 36 kg to 80 kg and door width from 701 mm to 1000 mm), with double speed adjustment with necessary accessories and screws etc. complete.
Providing and fixing double action hydraulic floor spring of approved brand and manufacture conforming to IS : 6315, having brand logo embossed on the body / plate with double spring mechanism and door weight upto 125 kg, for doors, including cost of cutting floors, embedding in floors as required and making good the same matching to the existing floor finishing and cover plates with brass pivot and single piece M.S. sheet outer box with slide plate etc. complete as per the direction of Engineer-in-charge. With stainless steel cover plate minimum 1.25 mm thickness
Providing and fixing 12 mm thick frameless toughened glass door shutter of approved brand and manufacture, including providing and fixing top & bottom pivot & spring type fixing arrangement and making necessary holes etc. for fixing required door fittings, all complete as per direction of Engineer-in-charge
Melamine polishing on wood work (one or more coat).
Providing and fixing glazing in door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge. (Cost of aluminium snap beading shall be paid in basic item): With float glass panes of 5.00 mm thickness
2 HOUR RATED WOODEN FIRE DOOR FRAME:- Supply of Pacific Make Fire door frames made out Hard wood of size 120 x 70mm (nominal) suitable for mounting shutters of 120 minutes fire rating, with grove for Intumescent fire seal strips (Imported) of size 10 mm x 4 mm provided in grooves on all three sides of the frame. (dash fastener to be paid seperately). SHUTTER:- Supply of Pacific make shutter of 46mm thick non - MTR.allic asbestos free fire resistant doors of 120minutes rating conforming to BS: 476 part 22/IS-3614 Part 2 as per prototype tested suitable for mounting on Frame, Shutter comprising of 70x40mm hardwood internal timber frame work, with 16mm thick infill Fire rated insulation filler, The insulation shall be sandwiched between 12mm thick Non-combustible Boards on both sides, cladded with 4mm thick commercial ply on both sides with heat activated intumescent fire seal strip of size 10 x 4mm mounted in the grooves of concealed hard wood lipping all around the shutter except bottom. (Door will be commercial ply finish only.) Hardwares Supply of SS Ball Bearing Hinges- 4" x 3" x 3mm. Make- Stanley Supply of Fire Rated Door Closer. Make- Geze/Stanley Supply of 6.8mm thick clear wired fire rated glass vision panel of size: 200 x 300mm. Make- Central Supply of Panic Bar for Double Leaf Door. Make- Geze/ Stanley. Supply of Trim. Make- Geze/ Stanley.
Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.).
Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works
Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete.
Chequerred precast cement concrete tiles 22 mm thick in footpath & courtyard, jointed with neat cement slurry mixed with pigment to match the shade of tiles, including rubbing and cleaning etc. complete, on 20 mm thick bed of cement mortar 1:4 (1 cement: 4 coarse sand). Dark shade pigment using ordinary cement
Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS : 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), including grouting the joints with white cement and matching pigments etc., complete. 800 x 800 mm size
Providing and laying Vitrified tiles in different sizes (thickness to be specified by the manufacturer), with water absorption less than 0.08% and conforming to IS: 15622, of approved brand & manufacturer, in all colours and shade, in skirting, riser of steps, laid with cement based high polymer modified quick set tile adhesive (water based) conforming to IS: 15477, in average 6 mm thickness, including grouting of joints (Payment for grouting of joints to be made separately).specification and direction of E/I. 800 x 800 mm size
Kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) : 25 mm thick
Kota stone slabs 20 mm thick in risers of steps, skirting, dado and pillars laid on 12 mm (average) thick cement mortar 1:3 (1 cement: 3 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing and polishing complete.
Providing and fixing granite 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for flooring, kitchen platforms, vanity counters, window sills , facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels. Granite of any colour and shade Area of slab over 0.50 SQM
Providing edge moulding to 18 mm thick marble/granite stone counters, Vanities etc., including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in-Charge. Granite work
Extra for providing opening of required size & shape for wash basin/ kitchen sink in kitchen platform, vanity counter and similar location in marble/ Granite/stone work, including necessary holes for pillar taps etc. including moulding, rubbing and polishing of cut edges etc. complete.
Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand), including pointing the joints with white cement and matching pigment etc., complete.
Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete.
Stone tile (polished) work for wall lining over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and cement slurry @ 3.3 kg/SQM including pointing in white cement complete. Granite of any colour and shade
Providing 50mm thick cement concrete flooring (1:2:4 with 20mm to 6mm size grade stone chips finish with flooring coat of neat cement in panels including cost of curing, finishing the surface smooth by rubbing with carborandum stone, taxes & royality with all complete as building specification and direction of E/I
Providing and laying 8mm thick wooden laminated flooring of Krono / Kronotex-Germany/Pergo or equivalent make of 8.0mm thick,AC-4,laid over underlay of polyurethane sheet and foam complete with nosing and all accessories etc,with 4 inch skirting all around all complete as per direction of Engineer-in-charge. i/c 1 ) Flooring, 2) Skirting, 3) A.profile Foam, 4) polythenes etc. Freight & cartage (Base Rate 1290/SQM)
Extra for filling grooves with polysulphide 6mm wide, 20mm deep.
Providing gola 75x75 mm in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 stone aggregate 10 mm and down gauge), including finishing with cement mortar 1:3 (1 cement : 3 fine sand) as per standard design : In 75x75 mm deep chase
Making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate of 20 mm nominal size) over P.V.C. sheet 1 m x1 m x 400 micron, finished with 12 mm cement plaster 1:3 (1 cement : 3 coarse sand) and a coat of neat cement, rounding the edges and making and finishing the outlet complete.
Roof/Terrace Water proofing:1) Cleaning the roof area properly using compressed air system to ensure that the substrate is free from dust, laitance, debris, etc. 2)Supply & application of Dr. Fixit LEC (Low energy consumption)system in order to achieve an initial U value of 0.51 W/SQM.K including proper termination of the system on to the vertical surfaces as per following sequence: - a) Spray apply an average 40 mm thk (as per ECBC U value requirement), Dr. Fixit Foam shield polyurethane foam system with density of 45-50 kg/cum as per ASTM D 1622, thermal conductivity of 0.023 W/m K at 25 oC as per ASTM C - 518 / 91, compressive strength with rise > 300 kPa as per ASTM D-1621 ,Fire resistance property confirming to Class B2 as per DIN 4102, and closed cell content having apparent vol of 96-98% (as per ASTM D 2856). b) Over the polyurethane foam, Supplying and applying Dr.Fixit Flexi PU 270(I) liquid-applied, highly permanent elastic, cold applied and cold curing, one component Polyurethane membrane having tensile strength of 3 - 4.25 N/mm2 (as per ASTM D 412), elongation of 400% (as per ASTM D 412) [email protected]/sq.mtr.
The system includes base preparation of cleaning, brushing and removal of flacky materials, grouting the porous area with cementitious grout, proper coving between slab and wall junctions and priming the surface with PU Primer(or equivalent) applied @ 150gms/Sqm. The coating shall be continued to the entire horizontal area and should be terminated at 300mm above the FFL / SFL complete as per manufacturer’s specification. The waterproofing system should be applied by the manufacturer approved partner applicator with 10 years of warranty against leakage. Products made in India will be given preference.All vertical surfaces will be fixed using prefixed gaskets etc. complete as per manufactures specification. c) A bitumen board or any other suitable board meant for construction joints shall be placed vertically at 3 to 4 MTR.res along the length and breadth of the roof area. Each rectangular bay formed in this manner shall not exceed 12 SQM. Average 80mm thick (or an equivalent thickness to achieve the required slope) Fibrated concrete screed of M 20 grade with Glass / polypropelene fibres shall be cast into these bays from a RMC pump (material, pump / machine shall be provided by you free of cost).
The panel joints to be cut and sealed with polysulphide sealant, Pidiseal PS 41 G / 42 P. The width of the sealant fill shall not be more than approx. 10 mm and 10 mm deep. d ) Supplying & laying 300 gsm Geotextile (non woven polyester) over the entire membrane maintaining proper overlaps. e) A bitumen board or any other suitable board meant for construction joints shall be placed vertically at 3x4 MTR.res along the length and breadth of the roof area. Each rectangular bay formed in this manner shall not exceed 12 SQM. Average 80mm thick (or an equivalent thickness to achieve the required slope) Fibrated concrete screed of M 20 grade with Glass / polypropelene fibres shall be cast into these bays from a RMC pump (material, pump / machine shall be provided by you free of cost).The panel joints to be cut and sealed with polysulphide sealant, Pidiseal PS 41 G / 42 P. The width of the sealant fill shall not be more than approx. 10 mm and 10 mm deep. f) All around on the roof, at the parapet wall junction, an angular fillet of 50 mm X 50 mm shall be trowel applied in cement-sand mortar Curing of the concrete screed & angle fillet shall be done as per regular concrete curing practices, by means of regularly wetting a hessian cloth.3) Providing & applying two coats
of UV resistant waterproof acrylic coating having SRI value 99 as per ASTM E 1980, Dr. Fixit Newcoat Ezee by roller / brush or spray application over roof surface, parapet walls & pedestals including surface preparation, cleaning & priming complete.
Toilet/Kitchen Water proofing: - 1) Surface preparation by grinding machine, cleaning , crack filling etc. complete. 2) Wrapping all pipe inserts with a two-way adhesion tape, Dr. Fixit Bathseal Tape, in the bathroom floor or wall or in the sunken portion, that is in contact with the pipe, promoting high adhesion between the grout and the pipe surface. 3) Grouting the gaps (annular space) between the pipe periphery & the inner side of the hole in the wall, with Dr. Fixit Bathseal Grout, cementitious, expanding, non-shrink grout that can give high early as well as ultimate strength to the grouted portion. Curing shall be as per good concrete practices, to ensure proper hardening and development of strength in the grout. Not more than 15% of water by wt. of the grout powder must be added to get proper flow and the physical strengths. 4) Providing and laying of fillets at the junction of slab and vertical walls prepared with cement sand mortar in the ratio 1 : 3 admixed with 5% of Dr. Fixit Pidicrete URP by weight of cement. 5) Applying two coats of Dr. Fixit Bathseal 2K ( 2 component, pre packed, cementitious flexible waterproofing coating with more than 100% elongation )@ 0.6 – 0.7 Sq.m. per kg in two coats all over the sunken portion floor, including over angular fillet, and extendable upto 300 mm over floor, achieving a uniform minimum thickness of 1.0 mm, all over the sunken portion of bathroom. Fixing of 150mm wide strip of woven glass fiber mesh all over the angle fillet all complete as per manufacture’s specifications.
6) Laying of protective plaster admixed with Dr.fixit Pidiproof LW+ (cement sand to be provided by client free of cost)
Basement waterproofing:(Treatment below Raft) 1) Clean all dirt, loose material and kept dry. In case of pot holes/cracks, the same shall be repaired with cement putty using Dr. Fixit Pidicrete URP. (Sand cement to be provided free of cost at site)
Below Raft - Supplying and installing 1.5 mm composite thick self adhesive fully bonded HDPE membrane, Dr.Fixit Prebond having tensile strength of >25 MPa as per ASTM D 412, elongation of >500% as per ASTM D 412, puncture resistance of > 1000 N as per ASTM E 154, UV resistant up to 45 days and conforming requirements of UG waterproofing structures, as per manufacturer's recommendation. The membrane should be minimum 2.4mx20m to reduce the number of joints, minimum 75mm factory made selvedges and comprising of an HDPE layer and a pressure sensitive adhesive layer which is covered by a weather proof protective and trafficable granular layer to protect self adhesive polymer layer. The waterproofing system should be applied by the manufacturer approved partner applicator with 10 years of warranty against leakage. Products made in India will be given preference.All vertical surfaces will be fixed using prefixed gaskets etc. complete as per manufactures specification.
Supply & installation of 180 gsm geotextile as a protection layer. Protecting the membrane with 50mm thick Screed (P.C.C)
Retaining Wall :- Providing and laying of minimum 1.5 mm thick SBS modified self adhesive waterproofing membrane topped with cross laminated HDPE valeron film, Dr. Fixit Samshield XL1500, having tensile strength of 3.5 N/mm2 and with minimum elongation (L/T) of 180% (as per ASTM D 882). The membrane shall have puncture resistance of >200 N (as per ASTM D 412 -06). The system includes base preparation of cleaning, brushing and removal of flacky materials, grouting the porous area with cementitious grout, proper coving between slab and wall junctions and priming the surface with cold applied bituminous primer, Dr. Fixit Torchshield primer (or equivalent), followed by installation of waterproofing membrane. The SBS membrane should be sealed properly at joints & maintaining 75 mm overlap between the membrane selvedge & 100 mm overlap on the end joints of the membrane over the surface etc. The waterproofing system should be applied by the manufacturer approved partner applicator with 10 years of warranty against leakage. Products made in India will be given preference.All vertical surfaces will be fixed using prefixed gaskets etc. complete as per manufactures specification.
a) Providing protection board of geodrain boad of 10mm thick fixed on to the membrane complete as per the specification and drawing. (In client's Scope)
Termination at vertical 3) Use a C- Shaped aluminium flashing strip or tuck it into a concrete wall of a groove of 12mmx12mm .T he aluminium flashing can be fitted to press the membrane into the groove and then be filled with a single component Dr. fixit PU sealant .
Providing 12mm thick cement plaster (1:6) with clean coarse sand of F.M. 1.5 including screening, curing with all leads and lifts of water, scaffolding taxes and royalty all complete as per specification and direction of E/I.
Providing 6mm thick cement plaster (1:4) in ceiling with clean coarse sand of F.M. 1.5 including screening, curing with all leads and lifts of water, scaffolding taxes and royalty all complete as per specification and direction of E/I.
Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface Water thinnable cement primer
18 mm cement plaster in two coats under layer 12 mm thick cement plaster 1:5 (1 cement : 5 coarse sand) finished with a top layer 6 mm thick cement plaster 1:6 (1 cement : 6 fine sand).
Finishing walls with water proofing cement paint of required shade :New work (Two or more coats applied @ 3.84 kg/10 SQM) SQM 57.85
Finishing walls with textured exterior paint of required shade : New work (Two or more coats applied @ 3.28 ltr/10 SQM) over and including priming coat of exterior primer applied @ 2.20kg/10 SQM
Distempering with 1st quality acrylic distemper, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre, of approved brand and m anufacture, including applying additional coats wherever required, to achieve even shade and colour.. Two coats
Wall painting with acrylic emulsion paint, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre, of approved brand and manufacture, including applying additional coats wherever required, to achieve even shade and colour.. Two coats
Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :Two or more coats on new work
Extra for plastering exterior walls of height more than 10 m from ground level for every additional height of 3 m or part thereof.
Providing and fixing factory made uPVC white colour fixed glazed windows/ventilators comprising of uPVC multi-chambered frame and mullion (where ever required) extruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), uPVC extruded glazing beads of appropriate dimension, EPDM gasket, G.I fasteners 100 x 8 mm size for fixing frame to finished wall, plastic packers, plastic caps and necessary stainless steel screws etc. Profile of frame shall be mitred cut and fusion welded at all corners, mullion (if required) shall be also fusion welded including drilling of holes for fixing hardware's and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealant over backer rod of required size and of approved quality, all complete as per approved drawing & direction of Engineer-in-Charge. (Single / double glass panes and silicon sealant shall be paid separately). Note: For uPVC frame, sash and mullion extruded profiles minus 5% tolerance in dimension i.e. in depth & width of profile shall be acceptable. Variation in profile dimension in higher side shall be accepted but no extra payment on this account shall be made. 9.147B.1 Fixed window / ventilator made of (small series) frame 47 x 50 mm & mullion 47 x 68 mm both having wall thickness of 1.9 ± 0.2 mm and single glazing bead of appropriate dimension. (Area upto 0.75 sqm.)
Providing and fixing factory made uPVC white colour sliding glazed window upto 1.50 m in height dimension comprising of uPVC multi-chambered frame with in-built roller track and sash extruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), appropriate dimension of uPVC extruded glazing beads and uPVC extruded interlocks, EPDM gasket, wool pile, zinc alloy (white powder coated) touch locks with hook, zinc alloy body with single nylon rollers (weight bearing capacity to be 40 kg), G.I fasteners 100 x 8 mm size for fixing frame to finished wall and necessary stainless steel screws etc. Profile of frame & sash shall be mitred cut and fusion welded at all corners, including drilling of holes for fixing hardware's and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealent over backer rod of required size and of approved quality, all complete as per approved drawing & direction of Engineer-in-Charge. (Single / double glass panes, wire mesh and silicon sealent shall be paid separately) Note: For uPVC frame and sash extruded profiles minus 5% tolerance in dimension i.e. in depth & width of profile shall be acceptable. Variation in profile dimension in higher side shall be accepted but no extra payment on this account shall be made. Three track three panels sliding window with fly proof SS wire mesh (Two nos. glazed & one no. wire mesh panels) made of (small series) frame 92 x 44 mm & sash 32 x 60 mm both having wall thickness of 1.9 ± 0.2 mm and single glazing bead of appropriate dimension (Area of window upto 1.75 sqm).
Providing and fixing double glazed hermetically sealed glazing in aluminium windows, ventilators and partition etc. with 6 mm thick clear float glass both side, having 12 mm air gap, including providing EPDM gasket, perforated aluminium spacers, desiccants, sealant (Both primary and secondary sealant) etc. as per specifications, drawings and direction of Engineer-in-charge complete.
Designing, fabricating, testing, protection, installing and fixing in position semi (grid) unitized system of structural glazing (with open joints) for linear as well as curvilinear portions of the building for all heights and all levels, including: a) Structural analysis & design and preparation of shop drawings for the specified design loads conforming to IS 875 part III (the system must passed the proof test at 1.5 times design wind pressure without any failure), including functional design of the aluminum sections for fixing glazing panels of various thicknesses, aluminium cleats, sleeves and splice plates etc. gaskets, screws, toggles, nuts, bolts, clamps etc., structural and weather silicone sealants, flashings, fire stop (barrier)- cum-smoke seals, microwave cured EPDM gaskets for water tightness, pressure equalisation & drainage and protection against fire hazard including:
b) Fabricating and supplying serrated M.S. hot dip galvanised / Aluminium alloy of 6005 T5 brackets of required sizes, sections and profiles etc. to accommodate 3 Dimentional movement for achieving perfect verticality and fixing structural glazing system rigidly to the RCC/ masonry/ structural steel framework of building structure using stainless steel anchor fasteners/ bolts, nylon seperator to prevent biMTR.allic contacts with nuts and washers etc. of stainless steel grade 316, of the required capacity and in required numbers. c) Providing and filling, two part pump filled, structural silicone sealant and one part weather silicone sealant compatible with the structural silicone sealant of required bite size in a clean and controlled factory / work shop environment , including double sided spacer tape, setting blocks and backer rod, all of approved grade, brand and manufacture, as per the approved sealant design, within and all around the periMTR.er for holding glass. d) Providing and fixing in position flashings of solid aluminium sheet 1 mm thick and of sizes, shapes and profiles, as required as per the site conditions, to seal the gap between the building structure and all its interfaces with curtain glazing to make it watertight. e) Making provision for drainage of moisture/
water that enters the curtain glazing system to make it watertight, by incorporating principles of pressure equalization, providing suitable gutter profiles at bottom (if required), making necessary holes of required sizes and of required numbers etc. complete. This item includes cost of all inputs of designing, labour for fabricating and installation of aluminium grid, installation of glazed units, T&P, scaffolding and other incidental charges including wastages etc., enabling temporary structures and services, cranes or cradles etc. as described above and as specified. The item includes the cost of getting all the structural and functional design including shop drawings checked by a structural designer, dully approved by Engineer-in-charge. The item also includes the cost of all mock ups at site, cost of all samples of the individual components for testing in an approved laboratory, field tests on the assembled working structural glazing as specified, cleaning and protection till the handing over of the building for occupation. In the end, the Contractor shall provide a water tight structural glazing having all the performance characteristics etc. all omplete as required, as per the Architectural drawings, as per item description, as specified, as per the approved shop drawings and as directed by the Engineerin-Charge.
Note:- 1. The cost of providing extruded aluminium frames, shadow boxes, extruded aluminium section capping for fixing in the grooves of the curtain glazing and vermin proof stainless steel wire mesh shall be paid for separately under relevant items under this subhead. However, for the purpose of payment, only the actual area of structural glazing (including width of grooves ) on the external face shall be measured in SQM. up to two decimal places.
Note:-2. The following performance test are to be conducted on structural glazing system if area of structural glazing exceeds 2500 SQM from the certified laboratories accreditated by NABL (National Accreditation Board for Testing and Calibration Laboratories), Department of Science & Technologies, India. Cost of testing is payable separately. The NIT approving authority will decide the necessity of testing on the basis of cost of the work, cost of the test and importance of the work. Performance Testing of Structural glazing system Tests to be conducted in the NBL Certified laboratories. 1. Performance Laboratory Test for Air Leakage Test (-50pa to – 300pa) & (+50pa to +300pa) as per ASTM E-283-04 testing MTR.hod for a range of testing limit 1 to 200 mVhr”. 2. Static Water Penetration Test. (50pa to 1500pa) as per ASTME- 331- 09 testing MTR.hod for a range up to 2000 ml.”. 3. Dynamic Water Penetration (50pa to 1500pa) as per AAMA 501.01- 05 testing MTR.hod for a range upto 2000 ml”. 4. Structural Performance Deflection and deformation by static air pressure test (1.5 times desing wind pressure without any failure) as per ASTME- 330-10 testing MTR.hod for a range upto 50 mm”. 5. Seismic Movement Test (upto 30 mm) as per AAMA 501.4-09 testing MTR.hod for Qualitative test” Tests to be conducted on site 6. Onsite Test for Water Leakage for a pressure range 50 kpa to 240 kpa (35psi) upto 2000ml”
Providing, assembling and supplying vision glass panels (IGUs) comprising of herMTR.ically-sealed 6-12- 6 mm insulated glass (double glazed) vision panel units of size and shape as required and specified, comprising of an outer heat strengthened float glass 6mm thick, of approved colour and shade with reflective soft coating on surface # 2 of approved colour and shade, an inner Heat strengthned clear float glass 6mm thick, spacer tube 12mm wide, dessicants, including primary seal and secondary seal (structural silicone sealant) etc. all complete for the required performances, as per the Architectural drawings, as per the approved shop drawings, as specified and as directed by the Engineer-in-Charge. The IGUs shall be assembled in the factory/ workshop of the glass processor. (Payment for fixing of IGU Panels in the curtain glazing is included in cost of item No.26.2) For payment, only the actual area of glass on face # 1 of the glass panels (excluding the areas of the grooves and weather silicone sealant) provided and fixed in position, shall be measured in SQM. (i) Coloured tinted float glass 6mm thick substrate with reflective soft coating on face # 2, + 12mm Airgap + 6mm Heat Strengthened clear Glass of approved make having properties as visible Light transmittance (VLT) of 25 to 35 %, Light reflection internal 10 to 15%, light reflection external 10 to 20 %, shading coefficient (0.25- 0.28) and U value of 3.0 to 3.3 W/SQM degree K etc. The properties of performance glass shall be decided by technical sanctioning authority as per the site requirement.
Extra for openable side / top hung vision glass panels (IGUs) including providing and supplying at site all accessories and hardwares for the openable panels as specified and of the approved make such as heavy duty stainless steel friction hinges, min 4 -point cremone locking sets with stainless steel plates, handles, buffers etc. including necessary stainless steel screws/ fasteners, nuts, bolts, washers etc. all complete as per the Architectural drawings, as per the approved shop drawings, as specified and as directed by the Engineerin- Charge.
Passenger Lifts 10 TO 16 Passenger 884 kgs G+5, Power operated, ACVVVF, 1.5 speed M/Sec. of approved design and make
Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge. With Toughened glass 12 mm thickness
Providing and fixing false ceiling at all height including providing and fixing of frame work made of special sections, power pressed from M.S. sheets and galvanized with zinc coating of 120 gms/SQM (both side inclusive) as per IS: 277 and consisting of angle cleats of size 25 mm wide x 1.6 mm thick with flanges of 27 mm and 37mm, at 1200 mm centre to centre, one flange fixed to the ceiling with dash fastener 12.5 mm dia x 50mm long with 6mm dia bolts, other flange of cleat fixed to the angle hangers of 25x10x0.50 mm of required length with nuts & bolts of required size and other end of angle hanger fixed with intermediate G.I. channels 45x15x0.9 mm running at the spacing of 1200 mm centre to centre, to which the ceiling section 0.5 mm thick bottom wedge of 80 mm with tapered flanges of 26 mm Each having lips of 10.5 mm, at 450 mm centre to centre, shall be fixed in a direction perpendicular to G.I. intermediate channel with connecting clips made out of 2.64 mm dia x 230 mm long G.I. wire at every junction,
Providing and fixing GI Clip in MTR.al Ceiling System of 600x600 mm module which includes providing and fixing 'C' wall angle of size 20x30x20 mm made of 0.5 mm thick pre painted steel along the periMTR.er of the room with help of nylon sleeves and wooden screws at 300 mm center to centre, suspending the main C carrier of size 10x38x10 mm made of G.I steel 0.7 mm thick from the soffit with help of soffit cleat 37x27x25x1.6 mm, rawl plugs of size 38x12 mm and C carrier suspension clip and main carrier bracket at 1000 mm c/c. Inverted triangle shaped Spring Tee having height of 24 mm and width of 34 mm made of GI steel 0.45 mm thick is then fixed to the main C carrier and in direction perpendicular to it at 600 mm centers with help of suspension brackets. Wherever the main C carrier and spring T have to join, C carrier and spring T connectors have to be used. including fixing periMTR.er channels 0.5 mm thick 27 mm high having flanges of 20 mm and 30 mm long, the periMTR.er of ceiling fixed to wall/partition with the help of rawl plugs at 450 mm centre, with 25mm long dry wall screws @ 230 mm interval, including fixing of gypsum board to ceiling section and periMTR.er channel with the help of dry wall screws of size 3.5 x 25 mm at 230 mm c/c, including jointing and finishing to a flush finish of tapered and square edges of the board with recommended jointing compound, jointing tapes, finishing with jointing compound in 3 layers covering upto 150 mm on both sides of joint and two coats of primer suitable for board, all as per manufacturer's specification and also including the cost of making openings for light fittings, grills, diffusers, cutouts made with frame of periMTR.er channels suitably fixed, all complete as per drawings, specification and direction of the Engineer in Charge but excluding the cost of painting with: 12.5 mm thick tapered edge gypsum plain board conforming to IS: 2095- Part I. All sections to be galvanized @ 120 gms/SQM (both side inclusive), fixing with clip in tiles into spring 'T' with: GI MTR.al Ceiling Clip in plain Beveled edge global white color tiles of size 600x600 and 0.5 mm thick with 25 mm height, made of G I sheet having galvanizing of 100 gms/ SQM (both sides inclusive) and 20% perforation area with 1.8 mm dia holes and having NRC of 0.5, electro statically polyester powder coated of thickness 60 microns (minimum), including factory painted after bending and perforation.
CARRAIGE OF MATERIALS
CEMENT ( 5KM )
SAND ( 40KM )
CHIPS ( 22KM )
METAL ( 22KM )
STEEL ( 5KM )
BRICKS ( 40KM )
CCTV SYSTEM
Supplying, installing, testing and commissioning of Dome camera 1/2.8" CMOS, F1.6~F3.3, Fixed Iris, 120dB, 50m IR, 0.001Lux, 1920x1080@30fps, 512 GB SD card slot, IP67, IK10, PoE, Built-in Mic, Audio 1/1, Alarm 2/1, Reset button, Smart VCA function, Face capture mode, Full Metal Housing. Make : Pelco/Birdeye/Axis
Supplying, installing, testing and commissioning of Bullet camera 1/2.8" CMOS, F1.6~F3.3, Fixed Iris, 120dB, 80m IR, 0.001Lux, 2592x1944@30fps, 2MP@60fps, 512 GB SD card slot, IP67, PoE, Built-in Mic, Audio 1/1, Alarm 2/1, Reset button, Smart VCA function, Face capture mode, Full Metal Housing. Make : Pelco/Birdeye/Axis
Supplying, installing, testing and commissioning of 64Ch, 320Mbps/320Mbps, recording resolution up to 12MP, decoding ability 4*8MP, 16*1080p, 32*720p, video output: 2 HDMI & 2VGA non-simultaneous output, alarm I/O 16/4, USB interface: 1xUSB 3.0 2xUSB 2.0, RAID: JBOD,RAID0/1/5/6/10, ANR, N+M Make : Pelco/Birdeye/Axis
Supply and drawing of UTP 4 pair 23 AWG CAT 6 LAN Cable in the existing surface/ recessed steel/ PVC conduit as required. 4 Pair CAT6 Unshielded, Twisted Pair (U/UTP) Cable. Blue/Orange/White/Green in colour conforming to the following standards like ANSI/TIA 568 C.2, EN50173, IEC 11801 2nd ED, frequency tested upto 700Mhz with Third Party Certificate etc.. Make:- Legrand/ Systimax /Scheinder
All-in-one recording solution for up to 16 channels, Pre-installed, pre-configured IP storage solution with 8 TB storage capacity, RAID-5 protected,Hot-swappable hard drives,Intel Xeon Quad Core X3430 (2.4 GHz, 8 M Cache, 95 W) Processor,4 GB memory installed, 2U rack mount, Temperature +10 °C to +35 °C, Relative humidity-8 to 90% (non-condensing), CE, UL Certified. Recording shall be calculated for all cameras at full frame rate & resolution for 15 days .with Intel i7 processor, 4GB RAM, 2TB HDD, 2 GB Dedicated NVidia Graphics card, Windows 7 or as recommended by VMS Software. The Workstation shall be suitable for any open platform software, as required as per specification & at site of work inline with the Engineer in Charge instructions.
32" Full HD LED Professional Display for Monitoring with mounting accessories
Layer 2 networking switch, 16# 10/100/1000 BT ports, 24 ports providing PoE as per 802.3a/f
19" 6U Rack for Switches complete as required omnitech/ Legrand/D-link
3x3 Juncation box with face place complete for Camera Omnitech / Legrand.
ELECTRICAL WORK
11 KV HT SYSTEM INCLUDING TRANSFORMER AND 11KV HT PANEL: - Supply and installation testing & commisioning of 630kVA , 3 phase ,11/0.433 KV step down dry type cast rasin indoor type with copper wound Dyn-11 connection and neutral brought out for earthing . The Transformer shall be provided with(+) 5% and (-)15% on load tap changer on HT side in step of 1.25% each. The Transformer shall be as per IS 1180. The Transformer shall be supplied with all accessories..6 channels temprature scaner with allarm and trip contacts, and thermistors.Diagram and rating plate shall be provided indicating the details of transform, connection diagram, Vector group, tap changing diagram etc. Jacking pads, handling and lifting lugs. Cover lifting eyes. Bi-directional rollers and skids( 4 Nos. Roller). Two grounding pads. Remote tap changer control panel.( RTCC). Rating and terminal marking plates. LT Neutral bushing with 50x10 cu flat suitably supported . Indoor HT cable box (Detachable type) suitable to terminate 3C-240 sq. mm 11kV HT cable. LT cable box (Detachable type) suitable for (1000A) 4Nos. 3.5Cx300 sq. mm LT cable. 630 KVA Transformer as per above
H.T & L.T CABLE
Supply of cable XLPE -PVC insulated PVC sheathed galvanised steel strip armoured electric power cable with aluminium conductor 11000 volt grade of size 3CX240 sqmm.
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of grede exceeding 1.1 KV but not exceeding 120 sq mm but not exceeding 400 sq mm diret in in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required 3c x 240 sqmm
Laying of one number PILCA/PVC insulated and PVC sheathed / XLPE power cable grede exceeding of 1.1 KV but not exceedind 11 KV of size not esceeding 120sq mm in the existing RCC/ HUME/STONE WARE / METAL pipe as required. 3c x 240 sqmm
Supplying and making indoor cable end jointing with cast resin compound, including lugs and other jointing materials, for following size of 3 core, XLPE aluminium conductor cable of 11 KV grade as required : 240 sq. mm
Supplying and making outdoor cable end jointing with cast resin compound, including lugs and other jointing materials, for following size of 3 core, XLPE aluminium conductor cable of 11 KV grade as required : 240 sq. mm
Supplying of following 1100 volt grade XLPE insulated PVC sheathed aluminium / Copper conductor armoured cables as per specification as required.
3.5 core 300sq. mm.
3.5 core 240sq. mm.
3.5 core 120sq. mm.
3.5 core 95sq. mm.
3.5 core 70sq. mm.
3.5 core 50sq. mm.
3.5 core 35sq. mm.
3.5 core 25sq. mm.
4 core 16sq. mm.
4 core 10 sq. mm.
4 core 10sq. mm.( Copper)
4 core 4sq. mm.( Copper)
4 core 2.5sq. mm.( Copper)
4 core 16sq. mm.( Copper)
4 core 25sq. mm.( Copper)
4 core 6sq. mm.( Copper)
3 core 4sq. mm.( Copper)
3 core 10sq. mm.( Copper)
3 core 6sq. mm.( Copper)
12 core 1.5sq. mm.( Copper)
7 core 1.5sq. mm.( Copper)
3 core 2.5sq. mm.( Copper)
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of size not exceeding 35 sq mm direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required.
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of size not exceeding 35 sq mm but not exceeding 95 sq mm direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required.
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of size not exceeding 95 sq mm but not exceeding 185 sq mm direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required.
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of size not exceeding 185 sq mm but not exceeding 400 sq mm direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required.
Laying of one number additional PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of size not exceeding 35 sq mm direct in ground in same trench in one tier horizontal formation including excavation, sand cushioning, protective covering and refilling the trench etc as required.
Laying of one number additional PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of size not exceeding 35 sq mm but not exceeding 95 sq mm direct in ground in same trench in one tier horizontal formation including excavation, sand cushioning, protective covering and refilling the trench etc as required.
Laying of one number additional PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of size not exceeding 95 sq mm but not exceeding 185 sq mm direct in ground in same trench in one tier horizontal formation including excavation, sand cushioning, protective covering and refilling the trench etc as required.
Laying of one number additional PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of size not exceeding 185 sq mm but not exceeding 400 sq mm direct in ground in same trench in one tier horizontal formation including excavation, sand cushioning, protective covering and refilling the trench etc as required.
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in size not exceeding 35 sq mm in the existing RCC/ HUME/ STONE WARE / METAL pipe/ Cable Trays as required.
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in size not exceeding 35 sq mm but not exceeding 95 sq mm in the existing RCC/ HUME/ STONE WARE / METAL pipe/ Cable Trays as required.
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in size not exceeding 95 sq mm but not exceeding 185 sq mm in the existing RCC/ HUME/ STONE WARE / METAL pipe/ Cable Trays as required.
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in size not exceeding 185 sq mm but not exceeding 400 sq mm in the existing RCC/ HUME/ STONE WARE / METAL pipe/ Cable Trays as required.
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing mansory open duct as required
Upto 25 sq. mm
Above 25 sq. mm and upto 400 sq. mm
Supplying and making end termination of following sizes with brass compression gland including providing and crimping solderless plugs/ferrules of sizes PVC insulated PVC sheathed aluminum conductor armoured cable 1.1 KV grade.
3.1/2 core 300sq. mm.
3.1/2 core 240sq. mm.
3.1/2 core 120sq. mm.
3.1/2 core 95sq. mm.
3.1/2 core 70sq. mm.
3.1/2 core 50sq. mm.
3.1/2 core 35sq. mm.
3.1/2 core 25sq. mm.
4core 16sq. mm.
4 core 10sq. mm.
3 core 10sq. mm.
4 core 6sq. mm.
4 core 4sq. mm.
3 core 4sq. mm.
12 core 1.5sq. mm.
7 core 1.5sq. mm.
3 core 2.5sq. mm.
Constructing masonry Chamber 90x90x100 cm inside, in brick work in cement mortar 1:4 (1 cement : 4 coarse sand) for sluice valve, with C.I. surface box 100 mm top diameter, 160 mm bottom diameter and 180 mm deep (inside) with chained lid and RCC top slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size ), i/c necessary excavation, foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size ) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12 mm thick, finished with a floating coat of neat cementcomplete as per standard design : With common burnt clay F.P.S.(non modular) bricks of class designation 7.5
Constructing masonry Chamber 60x60x75 cm inside, in brick work in cement mortar 1:4 (1 cement : 4 coarse sand) for sluice valve, with C.I. surface box 100mm top diameter, 160 mm bottom diameter and 180 mm deep ( inside) with chained lid and RCC top slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size ) , i/c necessary excavation, foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominalsize) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12 mm thick, finished with a floating coat of neat cement complete as per standard design : With common burnt clay F.P.S.(non modular) bricks of class designation 7.5
Constructing masonry Chamber 60x45x50 cm inside, in brick work in cement mortar 1:4 (1 cement : 4 coarse sand) for water meter complete with C.I. double flap surface box 400x200x200 mm (inside) with locking arrangement and RCC top slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) , i/c necessary excavation, foundation concrete 1:5:10 ( 1 cement : 5 fine sand:10 graded stone aggregate 40 mm nominal size) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12 mm thick, finished with a floating coat of neat cement complete as per standard design :With common burnt clay F.P.S.(non modular) bricks of class designation 7.5
Supply, erection, testing & commissioning of prefabricated MS ladder type cable trays including Tees / Bends / Crossing / Reducers / Couping to be laid in cable trench, overhead on wall or hanged from ceiling complete with all accessories as required including support at every 1500mm as required
1000 (W) x 75 (H) x 2mm (T)
600 (W) x 75 (H) x 2mm (T)
300 (W) x 50 (H) x 2mm (T)
150 (W) x 50 (H) x 2mm (T)
PERFORATED TYPE
MS perforated cable tray painted with powder coating 150 X 50 X 1.6 mm
MS perforated cable tray Connector 150 X 50 X 1.6 mm
MS perforated cable tray Bend 150 X 50 X 1.6 mm
MS perforated cable tray painted with powder coating 300 X 50 X 1.6 mm
MS perforated cable tray Connector 300 X 50 X 1.6 mm
MS perforated cable tray Bend 300 X 50 X 1.6 mm
Raceway & Junction boxes: - Providing and fixing 2 mm thick steel sheet factory fabricated post galvanized raceway with internal partition of the following sizes including providing removable 3 mm thick GI cover, knock out holes and fixing accessories earthing with 8 SWG copper earth wire complete, including cutting chases (with chase cutting machine) of floor as required , bends, access boxes, tap off boxes and cross over as per specification and site requirement.
300 mm wide x 40 mm deep raceway
200 mm wide x 40 mm deep raceway
Providing and fixing 350 x 350 x 50 mm deep 2 mm thick GI sheet junction box including providing 3 mm thick stainless steel cover as per specification.
Providing and fixing 250 x 250 x 50 mm deep 2 mm thick GI sheet junction box including providing 3 mm thick stainless steel cover as per specification.
Providing, laying and fixing following dia RCC pipe NP2 class (light duty) in ground complete with RCC collars, jointing with cement mortar 1:2 (1 cement : 2 fine sand) including trenching (75 cm deep) and refilling etc as required.
100 mm dia
150 mm dia
250 mmdia
Supply and laying of the following uPVC pipe(4 KgF) including excavation, refilling as required for cable entry including the cost of sealing the ends as required complete.
200mm outer dia
100mm outer dia
415V LT PANELS : - Design, fabrication, assembling, wiring & supply, installation, testing & commissioning of MV Panels fabricated out of 2mm thick for structural members (Load bearing members) and 1.6mm thick for door and covers (Non load bearing members) CRCA painted sheet steel in cubicle formation with reinforcement of suitable size angle iron, channels, T irons, flats wherever necessary for large meter boards. Cable gland plates shall be provided at top and bottom both and windows for meter reading, locking arrangement (pad-lock & seal) with wiring upto KWH meter & meter to MCB shall be done by using adequately rated flexible single core copper wire. The boards shall be treated with all anticorrosive process before painting as per standards with final approved shade of powder coated as approved, 2 nos. earthing terminals shall be provided for all panels. The boards shall be suitable for 415 V, 3 phase, 4 wire, 50 Hz supply system. Boards shall be fabricated in length, height, depth etc to match with site conditions. An approval shall be taken for each panel before manufacturing. Galvanised hardwares with zinc passivation shall be used in fabrication of boards. Note: The following provisions shall be required to be made in the switchboard detailed below. The Switchboard shall have provision for entry of all PVCA cables from the top/bottom as required. All live accessible parts shall
The features of AMF logic, Auto/manual/test, start/stop, EM stop operation including 3 attempt start feature, idle running timer, resumption of power supply after some time when EB supply has come back, shall be provided and integrated in the DG breaker cubicle. Set of relays, timer, Aux. Contactor etc as required for meeting the requirement of successful AMF shall be provided. BUS COUPLER: - 1 Nos. 1000 amps 4 pole EDO type air circuit breaker with microprocessor release unit for short circuit, over current and earth fault protection with adjustable setting as per specification and with following accessories: Breaker ON/ OFF/ TRIP indicating lamps, 24 V DC Shunt trip coil. - 1 Set, 240 V AC under voltage release. - 1 Set, Breaker control switch (TNC), Auxiliary contacts required for necessary interlocking of breakers.. Bus Bar section -I : 1500A, TPN Al. Bus Bar of suitable length having Current density 1Amp/sq.mm & having high conductivity electrical grade suitable to withstand symmetrical fault level of 35 kA. Neutral busbar shall be of 100% capacity.. Outgoings section-I: - 1 No. 630 Amps TPN Moulded Case Circuit Breaker (Icu = Ics) with built in Thermal Magnetic based release unit for short circuit and over current and with Dual type Tarrif Meter for measuring DG and Elec board power saparately and with CTs and Control MCB as required. 1 No. 630 Amps TP
Moulded Case Circuit Breaker (Icu = Ics) with built in Thermal Magnetic based release unit for short circuit and over current and with CTs and Control MCB as required for Capacitor Panel.. , 3 Nos. 400 Amps TPN Moulded Case Circuit Breaker (Icu = Ics) with built in Thermal Magnetic based release unit for short circuit and over current and with Dual type Tarrif Meter for measuring DG and Elec board power saparately and with CTs and Control MCB as required. 3 Nos. 160 Amps TPN Moulded Case Circuit Breaker (Icu = Ics) with built in Thermal Magnetic based release unit for short circuit and over current and with Dual type Tarrif Meter for measuring DG and Elec board power saparately and with CTs and Control MCB as required. 3 Nos. 100 Amps TPN Moulded Case Circuit Breaker (Icu = Ics) with built in Thermal Magnetic based release unit for short circuit and over current and with Dual type Tarrif Meter for measuring DG and Elec board power saparately and with CTs and Control MCB as required. Bus Bar section -II : : - 1500A, TPN Al. Bus Bar of suitable length having Current density 1Amp/sq.mm & having high conductivity electrical grade suitable to withstand symmetrical fault level of 50 kA. Neutral busbar shall be of 100% capacity.
Outgoings section-II: - 1 No. 630 Amps TPN Moulded Case Circuit Breaker (Icu = Ics) with built in Thermal Magnetic based release release unit for short circuit and over current and with Dual type Tarrif Meter for measuring DG and Elec board power saparately and with CTs and Control MCB as required, 1 No. 400 Amps TPN Moulded Case Circuit Breaker (Icu = Ics) with built in Thermal Magnetic based release unit for short circuit and over current and with Dual type Tarrif Meter for measuring DG and Elec board power saparately and with CTs and Control MCB as require, 2 Nos. 160 Amps TPN Moulded Case Circuit Breaker (Icu = Ics) with built in Thermal Magnetic based release unit for short circuit and over current and with Dual type Tarrif Meter for measuring DG and Elec board power saparately and with CTs and Control MCB as require, 5 No. 100 Amps TPN Moulded Case Circuit Breaker (Icu = Ics) with built in Thermal Magnetic based release unit for short circuit and over current and with Dual type Tarrif Meter for measuring DG and Elec board power saparately and with CTs and Control MCB as require. Main LT Panel Cum Change Over Panel as described above complete with specifications and enclosed SLD
MDB-1 (Basement Ventilation) Incoming: - 1 Nos. 400A, TPN MCCB (35KA) with thermal magnetic release having overload and short circuit protection. (Ics=100% Icu) and with following:- Metering & Indication: - 6 - Parameter Energy Analyser having 30 Days Memory with 3 No. 63/5A cast resin type CL: 1.0 CTs and MCB, R-Y-B and ON/OFF indication lamps for incomer with control MCB. Bus Bar:: - 500A, TPN Al. Bus Bar of suitable length having Current density 1Amp/sq.mm & having high conductivity electrical grade suitable to withstand symmetrical fault level of 35 kA. Neutral busbar shall be of 100% capacity. Outgoings:: - 20 Nos. 25 Amps TPN Moulded Case Circuit Breaker (Icu = Ics) with built in Thermal Magnetic based release unit for short circuit and over current , 2 Nos. 60 Amps TPN Moulded Case Circuit Breaker (Icu = Ics) with built in Thermal Magnetic based release unit for short circuit and over current. 3 Nos. 40 Amps TPN Moulded Case Circuit Breaker (Icu = Ics) with built in Thermal Magnetic based release unit for short circuit and over current, 18 Nos.DOL Starters, suitable for suitable motor, complete with thermal range as per Type-II co-ordination chart. (Ventilation Fans), 1 No.Star Delta Starters, suitable for suitable motor, complete with thermal range as per Type-II co-ordination chart. (Ventilation Fans). MDB-1( Ventilation Fans) as described above and complete as per enclosed SLD.
MDB-2 (Ground Floor) Incoming: - 1 Nos. 160A, TPN MCCB (25KA) with thermal magnetic release having overload and short circuit protection. (Ics=100% Icu) and with following:- Metering & Indication : - 6 - Parameter Energy Analyser having 30 Days Memory with 3 No. 100/5A cast resin type CL: 1.0 CTs and MCB, R-Y-B and ON/OFF indication lamps for incomer with control MCB. Bus Bar:: - 200A, TPN Al. Bus Bar of suitable length having Current density 1Amp/sq.mm & having high conductivity electrical grade suitable to withstand symmetrical fault level of 25 kA. Neutral busbar shall be of 100% capacity. Outgoings:- 2 Nos. 25 Amps TPN Moulded Case Circuit Breaker (Icu = Ics) with built in Thermal Magnetic based release unit for short circuit and over current, 6 Nos. 63 Amps TPN Moulded Case Circuit Breaker (Icu = Ics) with built in Thermal Magnetic based release unit for short circuit and over current, 4 Nos. 63 Amps 4P Moulded Case Circuit Breaker (Icu = Ics) with built in Thermal Magnetic based release unit for short circuit and over current with 63A 4P RCCB's, 2 Nos. DOL Starters, suitable for suitable motor, complete with thermal range as per Type-II co-ordination chart. (Ventilation Fans). MDB-2 (Ground, Floor) as described above and complete as per enclosed SLD,
MDB-3 (First Floor) Incoming: - 1 Nos. 160A, TPN MCCB (25KA) with thermal magnetic release having overload and short circuit protection. (Ics=100% Icu) and with following:- Metering & Indication : - 6 - Parameter Energy Analyser having 30 Days Memory with 3 No. 160/5A cast resin type CL: 1.0 CTs and MCB, R-Y-B and ON/OFF indication lamps for incomer with control MCB. Bus Bar:: - 200A, TPN Al. Bus Bar of suitable length having Current density 1Amp/sq.mm & having high conductivity electrical grade suitable to withstand symmetrical fault level of 25kA. Neutral busbar shall be of 100% capacity. Outgoings:: - 1 Nos. 100 Amps TPN Moulded Case Circuit Breaker (Icu = Ics) with built in Thermal Magnetic based release unit for short circuit and over current , 5 Nos. 63 Amps TPN Moulded Case Circuit Breaker (Icu = Ics) with built in Thermal Magnetic based release unit for short circuit and over current , 2 Nos. 25 Amps TPN Moulded Case Circuit Breaker (Icu = Ics) with built in Thermal Magnetic based release unit for short circuit and over current , 2 Nos. DOL Starters, suitable for suitable 5.5 Kw motor, complete with thermal range as per Type-II co-ordination chart. (Ventilation Fans). MDB-3 (First Floor) as described above and complete as per enclosed SLD.
SDB-3.1 (Second Floor) Incoming: - 1 Nos. 100A, TPN MCCB (25KA) with thermal magnetic release having overload and short circuit protection. (Ics=100% Icu) and with following:- Metering & Indication : - 6 - Parameter Energy Analyser having 30 Days Memory with 3 No. 250/5A cast resin type CL: 1.0 CTs and MCB, R-Y-B and ON/OFF indication lamps for incomer with control MCB. Bus Bar: - 150A, TPN Al. Bus Bar of suitable length having Current density 1Amp/sq.mm & having high conductivity electrical grade suitable to withstand symmetrical fault level of 25 kA. Neutral busbar shall be of 100% capacity. Outgoings: 5 Nos. 60 Amps TPN Moulde Case Circuit Breaker (Icu = Ics) with built in Thermal Magnetic based release unit for short circuit and over current, 2 Nos. 25 Amps TPN Moulded Case Circuit Breaker (Icu = Ics) with built in Thermal Magnetic based release unit for short circuit and over current , 2 Nos. DOL Starters, suitable for suitable 5.5Kw motor, complete with thermal range as per Type-II co-ordination chart. (Ventilation Fans). SDB-3.1 (Second Floor) as described above and complete as per enclosed SLD.
MDB-4 (Third Floor) Incoming : - 1 Nos. 160A, TPN MCCB (25KA) with thermal magnetic release having overload and short circuit protection. (Ics=100% Icu) and with following:- Metering & Indication: - 6 - Parameter Energy Analyser having 30 Days Memory with 3 No. 250/5A cast resin type CL: 1.0 CTs and MCB, R-Y-B and ON/OFF indication lamps for incomer with control MCB. Bus Bar: 200A, TPN Al. Bus Bar of suitable length having Current density 1Amp/sq.mm & having high conductivity electrical grade suitable to withstand symmetrical fault level of 25 kA. Neutral busbar shall be of 100% capacity. Outgoings: 5 Nos. 60 Amps TPN Moulded Case Circuit Breaker (Icu = Ics) with built in Thermal Magnetic based release unit for short circuit and over current, 1 Nos. 100 Amps TPN Moulded Case Circuit Breaker (Icu = Ics) with built in Thermal Magnetic based release unit for short circuit and over current, 2 Nos. 25 Amps TPN Moulded Case Circuit Breaker (Icu = Ics) with built in Thermal Magnetic based release unit for short circuit and over current, 2 Nos. DOL Starters, suitable for suitable 5.5Kw motor, complete with thermal range as per Type-II co-ordination chart. (Ventilation Fans). MDB-4 (Third Floor) as described above and complete as per enclosed SLD.
SDB-4.1 (Fourth Floor) Incoming: - 1 No. 100A, TPN MCCB (25KA) with thermal magnetic release having overload and short circuit protection. (Ics=100% Icu) and with following:- Metering & Indication : - 6 - Parameter Energy Analyser having 30 Days Memory with 3 No. 200/5A cast resin type CL: 1.0 CTs and MCB, R-Y-B and ON/OFF indication lamps for incomer with control MCB. Bus Bar: - 150A, TPN Al. Bus Bar of suitable length having Current density 1Amp/sq.mm & having high conductivity electrical grade suitable to withstand symmetrical fault level of 25 kA. Neutral busbar shall be of 100% capacity. Outgoings: - 5 Nos. 60 Amps TPN Moulded Case Circuit Breaker (Icu = Ics) with built in Thermal Magnetic based release unit for short circuit and over current, 2 Nos. 25Amps TPN Moulded Case Circuit Breaker (Icu = Ics) with built in Thermal Magnetic based release unit for short circuit and over current, 2 Nos. DOL Starters, suitable for suitable 5.5Kw motor, complete with thermal range as per Type-II co-ordination chart. (Ventilation Fans). SDB-4.1 (Fourth Floor) as described above and complete as per enclosed SLD
MDB-5 (Fifth Floor) Incoming: - 1 Nos. 160A, TPN MCCB (25KA) with thermal magnetic release having overload and short circuit protection. (Ics=100% Icu) and with following:- Metering & Indication : - 6 - Parameter Energy Analyser having 30 Days Memory with 3 No. 250/5A cast resin type CL: 1.0 CTs and MCB, R-Y-B and ON/OFF indication lamps for incomer with control MCB. Bus Bar: - 200A, TPN Al. Bus Bar of suitable length having Current density 1Amp/sq.mm & having high conductivity electrical grade suitable to withstand symmetrical fault level of 25 kA. Neutral busbar shall be of 100% capacity. Outgoings: - 5 Nos. 60 Amps TPN Moulded Case Circuit Breaker (Icu = Ics) with built in Thermal Magnetic based release unit for short circuit and over current, 1 Nos. 100 Amps TPN Moulded Case Circuit Breaker (Icu = Ics) with built in Thermal Magnetic based release unit for short circuit and over current, 2 Nos. 25 Amps TPN Moulded Case Circuit Breaker (Icu = Ics) with built in Thermal Magnetic based release unit for short circuit and over current, 2 Nos. DOL Starters, suitable for suitable 5.5Kw motor, complete with thermal range as per Type-II co-ordination chart. (Ventilation Fans), MDB-5 (Fifth Floor) as described above and complete as per enclosed SLD.
MDB-Lift Panel: Incoming: - 1No. 125A 4 pole manual change over switch. 1Nos. 125A, TPN MCCB with thermal magnetic release having overload and short circuit protection. (Ics=100% Icu) and with following: - Metering & Indication : - 6 - Parameter Energy Analyser having 30 Days Memory with 3 No. 250/5A cast resin type CL: 1.0 CTs and MCB, R-Y-B and ON/OFF indication lamps for incomer with control MCB. Bus Bar:: - 200A, TPN Al. Bus Bar of suitable length having Current density 1Amp/sq.mm & having high conductivity electrical grade suitable to withstand symmetrical fault level of 25 kA. Neutral busbar shall be of 100% capacity. Outgoings:: - 4 Nos. 60 Amps TPN Moulded Case Circuit Breaker (Icu = Ics) with built in Thermal Magnetic based release unit for short circuit and over current. 1 No. 40 Amps TPN Moulded Case Circuit Breaker (Icu = Ics) with built in Thermal Magnetic based release unit for short circuit and over current. MDB-Lift Panel as described above and complete as per enclosed SLD.
MDB-Fire Fighting Panel (Basement) Incoming: - 1 Nos. 400A, TPN MCCB (25KA) with thermal magnetic release having overload and short circuit protection. (Ics=100% Icu) and with following:- Metering & Indication : - 6 - Parameter Energy Analyser having 30 Days Memory with 3 No. 400/5A cast resin type CL: 1.0 CTs and MCB, R-Y-B and ON/OFF indication lamps for incomer with control MCB. Bus Bar: - 500A, TPN Al. Bus Bar of suitable length having Current density 1Amp/sq.mm & having high conductivity electrical grade suitable to withstand symmetrical fault level of 25 kA. Neutral busbar shall be of 100% capacity. Outgoings: - 3 Nos. 160 Amps TPN Moulded Case Circuit Breaker (Icu = Ics) with built in Thermal Magnetic based release unit for short circuit and over current. MDB-Fire Fighting Panel (Basement) as described above and complete as per enclosed SLD.
Plumbing Panel (Basement) Incoming: - 1 Nos. 100A, TPN MCCB (25KA) with thermal magnetic release having overload and short circuit protection. (Ics=100% Icu) and with following:- Metering & Indication : - 6 - Parameter Energy Analyser having 30 Days Memory with 3 No. 100/5A cast resin type CL: 1.0 CTs and MCB, R-Y-B and ON/OFF indication lamps for incomer with control MCB. Bus Bar:- 150A, TPN Al. Bus Bar of suitable length having Current density 1Amp/sq.mm & having high conductivity electrical grade suitable to withstand symmetrical fault level of 25 kA. Neutral busbar shall be of 100% capacity. Outgoings: - 3 Nos. 40 Amps TPN Moulded Case Circuit Breaker (Motor Duty) (Icu = Ics) with built in Thermal Magnetic based release unit for short circuit and over current, 9 Nos. 25 Amps TPN Moulded Case Circuit Breaker (Motor Duty) (Icu = Ics) with built in Thermal Magnetic based release unit for short circuit and over current. Plumbing Panel (Basement) as described above and complete as per enclosed SLD
MDB-UPS (Basement UPS Room) Incoming: - 2 Nos. 125A, FP MCCB with thermal magnetic release having overload and short circuit protection. (Ics=100% Icu) and with following:- Metering & Indication , 6 - Parameter Energy Analyser having 30 Days Memory with 3 No. 250/5A cast resin type CL: 1.0 CTs and MCB (2 set), R-Y-B and ON/OFF indication lamps for incomer with control MCB (2 set). Bus coupler: 1 No. 125A, FP MCCB with thermal magnetic release having overload and short circuit protection. (Ics=100% Icu) with both Bus with mechanical Interlocking. Bus Bar:- 20A, TPN Al. Bus Bar of suitable length having Current density 1Amp/sq.mm & having high conductivity electrical grade suitable to withstand symmetrical fault level of 25 kA. Neutral busbar shall be of 100% capacity. Outgoings:- 18Nos. 63A, FP MCCB with thermal magnetic release having overload and short circuit protection. (Ics=100% Icu) and with following:- MDB-8 UPS as described above and complete as per enclosed SLD
EXTERNAL LIGHTING FEEDER PILLAR (10 kA): - Design, fabrication, supply of Feeder Pillar fabricated out of 2mm thick for structural members (Load bearing members) and 1.6mm thick for door and covers (Non load bearing members) CRCA sheet in cubicle compartmentalize free standing floor mounted, dust and vermin proof outdoor type double door with reinforcement of suitable size angle iron, channel 'T' irons and / or flats wherever necessary. Cable gland plates shall be provided at the bottom of the panels. Panels shall be treated with all anticorrosive process before powder coating as per specifications with 2 coats of PU paint primer and final approved shade of PU paint coating. 2 Nos. earthing terminals shall be provided for all distribution panels. Panels shall be suitable for 415V, 3-phase, 4-wire, 50Hz supply system and with 15% spare space, lifting hooks shall also be provided in case of large panels. Approval shall be taken for each panel before fabrication. Galvanized hardwares with zinc passivation shall be used in fabrication of panels. INCOMING: - 1 no. 63 Amp TPN MCCB, 10 KA with thermal magnetic protective releases. 1 no 24 hrs programmable timer & contactor complete for automatic operation of external lighting. 1 set of phase indicating lamps with MCB. BUSBAR : - 100 Amp FP aluminium busbars (Current Density 1A/Sq.mm) with 100% neutral. OUTGOING : - 12 nos. 20A/25A amp DP MCB, 10 KA with thermal magnetic protective releases.
Installation, testing and commissioning External lighting Feeder Pillars as mentioned in item No. 1 above fabricated out of 2mm thick for structural members (Load bearing members) and 1.6mm thick for door and covers (Non load bearing members) CRCA sheet in cubicle compartmentalize free standing floor mounted, dust and vermin proof outdoor type double door including providing & making brick masonry foundation (including plastering etc.) of suitable size with all fixing accessories as required.
INTERNAL WIRING AND FINAL DISTRIBUTION BOARDS (COPPER WIRING IN PVC CONDUITS): -
Point Wiring in PVC conduit with Modular type switch :- Wiring for Light point / Fan point / Exhaust Fan point / Call Bell point with 1.5 sq.mm FR PVC insulated copper conductor single core cable in surface / recessed PVC conduit , with modular switch ,modular plate ,suitable GI box as required . a) Group - C
Wiring for light/ceiling fan/exhaust fan/call bell point with 2x1.5 sq.mm PVC insulated stranded copper conductor cable alongwith 1 No. 1.5 sq.mm PVC insulated copper conductor cable for earthing in PVC Medium conduit as required. (Point shall be controlled / looped From existing point).
Wiring with 2 x 2.5 sq.mm FR PVC insulated copper conductor single core cable in surface / recessed PVC conduit alongwith 1 No. 2.5 sq.mm FR PVC insulated copper conductor single core cable for loop earthing as required.( For primary 5A Socket and Primary MCB Point)
Wiring for Circuit wiring with 2 x 2.5 sq.mm FR PVC insulated copper conductor single core cable in surface / recessed PVC conduit alongwith 1 No. 2.5 sq.mm FR PVC insulated copper conductor single core cable for loop earthing as required.( For Circuit wiring)
Wiring with 2 x 1.5 sq.mm FR PVC insulated copper conductor single core cable in surface / recessed PVC conduit alongwith 1 No. 1.5 sq.mm FR PVC insulated copper conductor single core cable for loop earthing as required.( For Secondary MCB Points and 5A Secondary Points)
Wiring for light / power plug point with 2 x 4 sq.mm FR PVC insulated copper conductor single core cable in surface / recessed PVC Medium Class conduit alongwith 1 No. 4 sq.mm FR PVC insulated copper conductor single core cable for loop earthing as required.( For 16A Socket)
Wiring for light / power plug point with 2 x 6 sq.mm FR PVC insulated copper conductor single core cable in surface / recessed PVC conduit alongwith 1 No. 6sq.mm FR PVC insulated copper conductor single core cable for loop earthing as required.( For Kitchen Sockets)
POWER SOCKETS
Supplying and fixing suitable size GI box with modular plate and cover in Front on surface or in recess ,including providing and fixing 3 pin 5 / 6 amps modular socket outlet and 5 / 6 amps modular switch,connection,painting etc.as required.
Supplying and fixing suitable size GI box with modular plate and cover in Front on surface or in recess ,including providing and fixing 6 pin 15 / 16 modular socket outlet and 15 / 16 amps modular switch,connection,painting etc.as required.
FINAL DISTIRIBUTION BOARD
Supplying installation, testing and commissioning of surface-recess mounting type three pole and neutral,prewired, sheet steel, MCB distribution board 415 volt, tinned copper busbar, common netrul link, earth bar, din bar for mounting MCB detachable gland /knock out plate,, phosphatized and powder coated and complete with MCBs . RCCBs , Isolator etc as required. TPN DB ( Double door). A. TP&N D.B (HORIZONTAL TYPE). i) 1 No. 40 Amps 4P MCB Isolator. ii) 3 No. 40 Amps 2P RCCB . iii) 12 Nos. 10-20 Amps SP MCBs as outgoing.
A. TP & N D.B (HORIZONTAL TYPE): - i) 1 No. 40 Amps 4P MCB Isolator. ii) 3No. 40 Amps 2P RCCB, iii) 18 Nos. 10-20 Amps SP MCBs as outgoing
A. TP&N D.B (HORIZONTAL TYPE): - i) 1 No. 60 Amps 4P MCB Isolator. ii) 3 No. 60 Amps 2P RCCB , iii) 24 Nos. 10-20 Amps SP MCBs as outgoing
A. TP&N D.B (HORIZONTAL TYPE): - i) 1 No. 60 Amps 4P MCB Isolator, ii) 3 No. 60 Amps 2P RCCB and iii) 30 Nos. 10-20 Amps SP MCBs as outgoing
Supplying installation, testing and commissioning of surface-recess mounting type Single pole and neutral,prewired, sheet steel, MCB distribution board 240 volt, tinned copper busbar, common netrul link, earth bar, din bar for mounting MCB detachable gland /knock out plate,, phosphatized and powder coated and complete with MCBs . RCCBs , Isolator etc as required. SP&N D.B (HORIZONTAL TYPE), i) 1 No. 25 Amps 2P MCB, i) 1 No. 25 Amps 2P RCCB, ii) 6 Nos. 6-10 Amps SP MCBs as outgoing
TELEPHONE, DATA and TV:: - Providing, fixing, connecting and testing of following pair solderless telephonetag block, with powder coated box (Krone make ) of required size box with hinged lockable cover and clamps for dressing of wires etc as required.
100 Pair box
50 Pair box
10 Pair box
Supply and laying of following 0.61mm dia annealed tinned copper conductor PVC insulated and PVC sheathed unarmoured telephone cable in existing conduit in concealed/ surface system complete as required
100 pair Cable
50 pair Cable
10 pair Cable
Providing, fixing, connecting, testing and commisssioning of zinc passivated box with moulded plate in recess or on surface moulded type with following including all necessary materials etc. as required.
Computer terminal (RJ-45)
2 Pair telephone cord outlet (RJ-11)
TV antina Socket outlet
Supplying and fixing of following size PVC conduit alongwith the accessories in surface / recess including painting in case of surface conduit or cutting and making good the same in case of recessed conduit as required as per specification.
20mm dia
25mm dia
32mm dia
Providing and fixing of CAT-5 (E) giga speed cable unarmoured copper conductor FR computer cables of reputable make in existing conduits .
Supplying and drawing co-axial TV cable RG-6 grade, copper conductor PE insulated, with PVC shield in the existing surface/ recessed PVC conduit as required.
Supplying, drawing, of 0.5mm dia (2 pair) FR PVC insulated copper conductor , unarmoured telephone cable in existing surface/ recessed PVC conduit as required
Supplying, drawing, of 0.5mm dia (3 pair) FR PVC insulated copper conductor , unarmoured telephone cable in existing surface/ recessed PVC conduit as required
S.I.T.C of floowing rating reccess/surface mounted LED round /square shape Down Light Luminarie with pressure die cast housing for single phase supply voltage. Luminarie shall be confirm to IS:10322 part-5/section-2 or IEC:62722 with all neccssary accessories as required.
2'X2' led Light
18/20W Led Light
12W Led Light
20/22W Led tube light
Bulkhead 10W Led Light
Supply and fixing circular/ hexagonal M.S. sheet ceiling fan box with clamp of internal dia 140mm, 73 mm height, 3mm thick rim top lid of 1.5mm thick M.S sheet lidss shall be screwed into M.S. box by means of 3mm round headed screws, clamps shall be made of 12 mm dia M.S bar bent to be shape as per standard drawing with over all length as 80 cm
Supply and fixing moduler type electronic fan regulator:- Supply and fixing stepped type electronic fan regulator on the existing modular plate & switch box including connections but excluding modular plate etc. as reuired.
S/F Modular boxes, base & cover Plate:- Supplying and fixing following size /modules , GI box alongwith modular base & cover plate for modular switches in recess etc. as required. 1 or 2 module (78 x 78 x 45)
Supply Installation , testing and commssioning of follwing size ceiling fan 3 blades confirming to IS:374:2019 including wiring the down road of standard length up to 30 cm with 1.5sq.mm FR PVC insulated , copper wire suitable for 230V 50Hz , single phase supply etc. complete as required. 1200mm (48") Ceiling Fan
Supplying and fixing following 4/5 Module base & cover plate on existing modular metal boxes etc. as required.
FIRE ALARM SYSTEM (ADDRESSABLE TYPE)-
Supply, Installation , Testing & Commissioning of Microprocessor based (1 +1 reduntant) panel , Networkable analogue addressable type single cabinet fire alarm control panel with Touch screen/ LCD display with with minimum history of 2 X 1000 event. The panel shall be equipped with sufficient numbers of loop with 10-20% spare capacity with each loop and shall have a capacity of 99/99 of analogue detector /devices in one loop. The panel shall have dedicated control for controlling of dampers, smoke curtains, AHUs, pressurization fans, ventilation fans at fire pump room, monitoring of fire sprinkler and fire hydrant pump, 240 volts AC power supply, automatic battery charger, 24 volts sealed lead acid batteries sufficient for 24 hours normal working conditions as required in EN standard and respective NBC. The Panel shall have BACKNET & MODBUS CARD integration . The complete panel assembly shall come with 1+1 redundancy at all level loop cards, CPU, network card, display, power supply as well as shall have integrated voice evacuation . Panel shall be EN complied VDS /LPCB/BRE approved or NFPA complied UL/FM. 4 loop. Make:- Noburn/Wrexham/Pyrotynex
Supply, Installation , Testing & Commissioning of Automatic Analog addressable VDS/LPCB/UL/FM approved with respective standard of Smoke detector, having fault Isolators integrated in detector for maintaining operational availability of all elements in the loop, even in the event of a short circuit & detector shall have sensitivity as automatic drift compensation type at variable environment, with mounting based LED, Address Switch / electronic address to programme the detectors, complete as required.In case detector isnot with inbuilt fault isolator, Fault isolator module shall be provided with each and individual detector. Make : Autronica Hampton/Gamewell/Notifier-3030 series
Supply, Installation , Testing & Commissioning of Automatic Analog addressable VDS/LPCB/UL/FM approved with respective standard of Heat detector, having fault Isolators integrated in detector for maintaining operational availability of all elements in the loop, even in the event of a short circuit & detector shall have sensitivity as automatic drift compensation type at variable environment, with mounting based LED, Address Switch / electronic address to programme the detectors, complete as required. In case detector isnot with inbuilt fault isolator, Fault isolator module shall be provided with each and individual detector. Make : Autronica Utc/Hampton/Gamewell /Notifier-3030 series
Supply, Installation, Testing and Commissioning of Beam Detector. The beam detector shall be used for High Ceiling application with a detection range upto 50- 70 mtrs sensitive settings. Make : Autronica Utc/Hampton/Gamewell/Notifier-3030 series
Supply, Installation , Testing & Commissioning of Response Indicator which consists of steady glowing LED. This LED shall be mounted within a box and connected in parallel to the built in indicator of the detector as per specifications. The RI shall come "ON" as soon as the detector activates complete in all respects as per specification.The RI shall be of same make as of panel. Make : Autronica Utc/Hampton/Gamewell/Notifier-3030 series
Supply, Installation , Testing & Commissioning of Addressable type VDS/LPCB/UL/FM approved with respective standard of addressable manual call (pull type) Station with inbuilt fault isolator complete with all accessories as per specifications. In case device isnot with inbuilt fault isolator, Fault isolator module shall be provided with each and individual device. Make : Autronica Utc/Hampton/Gamewell/Notifier-3030 series
Supply, Installation, Testing & Commissioning of VDS/LPCB/UL/FM approved with respective standard of loop powered addressable Sounders cum flasher with inbuilt fault isolator base at 90-100db .to notify Occupants for fast & safe Evacuation as specified.In case if sounder cum flasher isnot loop powered, the cable and its acessories required to provide power supply to sounder cum flasher shall be inclusive. Make : Autronica Utc/Hampton /Gamewell/Notifier-3030 series
Supplying and installation of Exit Signs: photo luminescent safety signage made up of photo luminescent material of rare earth aluminates, non radioactive working on the principle of high processed on 1.2 mm thick aluminum sheet including arrangement for fixing on wall / ceiling etc. complete as required (single sided) (size 150 mm x 300 mm). Make:- Evenlite/Hampton/Verbatim
Supplying and fixing of following sizes of STEEL conduit alonwith the accessories in surface/recess including painting in case of surface conduit, or cutting the wall and making good the same in case of recessed conduit as required. Make:- AKG/BEC
20mm dia
25mm dia
32mm dia
Supplying and drawing of following sizes of Low Smoke Zero Halogen Silicon Insulated Fire Survival Cable with Drain Wire, solid copper conducter cable approved by LPCB as per BSEN 50200:2015 PH 120 (Fire, Mech Shock & Water 120 Minutes @ 830 deg Celcius, Fire & Mech Shock every 5 Min for 2 Hours- Both test conducted on same sample) and BS-6387 CWZ The cable shall sustain 950 deg. C. The cable shall be approved for. The cable shall be BS EN 60332-1-2:2004 for Bunched Flame Retardancy (installed as a single or bunched cable self extinguishes leaving the upper cable sheath unaffected showing the cable does not propagate fire). Cable shall be guaranteed for 10 years from the date of manufacture marked on the cable. 2 X 1.5 sq. mm Make:- Noburn/Wrexham/Pyrotynex
PUBLIC ADDRESS SYSTEM
Supplying, installing, testing and commissioning of Voice Evacuation Master controller with built in Amplifier. The System have Built in 500W Amplifier and it should be capable for the EVAC, Paging, PA and BGM functions. The Controller have SD card option to store the EVAC and Alert Voice Message. The Controller have Speaker line supervision record out and amplifier auto changeover. The Controller have following features: Separate Zone volume control at the front side of panel, Status indications on the Panel for EVAC,Fault ,AC,DC ,Fault, ALERT & Fireman mic, Zone capacity up to 96 Zones, 8 programmable Control Input and output, Fireman Microphone with High Priority, Frequency response 80Hz - 20kHz, 25V/70V/100V Class-AB Speaker Output. In capacity of individual or sum of amplifier wattage shall be 500W.The acessories required to sum of these amplifier to 500W shall also be inclusive in this. Make : Autronica Utc/Hampton/Gamewell/Notifier-DAA series
Supplying, installation, testing & commissioning of 1.5/3/6W metal box ceiling/wall speakers complete as required. Make : Autronica Utc/Hampton /Gamewell /Notifier-L serires
Supplying, installing, testing and commissioning of 12 zone paging microphone (call station) with necessary Zone wise, Group Zones and all call facility. The Microphone should have LED Indication, Can be Expand with additional units, Compress function through microphone input to avoid distortion, Auxiliary input which supply local background music. Power 24V DC, Microphone should be able to Control the Music also. Microphone Should supply with all accessaries and with standard specification, complete. Make : Autronica Utc/Hampton/Gamewell/Notifier-3030 series
Supplying, installing, testing and commissioning of Network Resource Interface, 4 channels network audio source, 32 dry contacts in and 8 try contacts out for Fire Alarm Interface. Make:- Hampton/Autronica/ Gamewell/Johnson IFC series/Notifier Series
Supplying and drawing of following sizes of Low Smoke Zero Halogen Silicon Insulated Fire Survival Cable with Drain Wire, solid copper conducter cable approved by LPCB as per BSEN 50200:2015 PH 120 (Fire, Mech Shock & Water 120 Minutes @ 830 deg Celcius, Fire & Mech Shock every 5 Min for 2 Hours- Both test conducted on same sample) and BS-6387 CWZ The cable shall sustain 950 deg. C. The cable shall be approved for. The cable shall be BS EN 60332-1-2:2004 for Bunched Flame Retardancy (installed as a single or bunched cable self extinguishes leaving the upper cable sheath unaffected showing the cable does not propagate fire). Cable shall be guaranteed for 10 years from the date of manufacture marked on the cable. 2 X 1.5 sq. mm. Make:- Noburn /Wrexham/Pyrotynex
Supply , Installation , testing and commisioning of 30 kVA online UPS 3 Phase input and 3 Phase output power system of input , voltage range 360V/380V/400/485V AC frecuency range 40HZ 60HZ+_ 10% output Voltage range 415V +_ 1% frequancy range 50Hz +_ 1% power fecor 0.8/3.1harmonic distrortion-< 2% THD (Liner load ) 5% THD ( non linier load )
Supply , Installation , testing and commisioning of 30 kVA online UPS single Phase input and single Phase output power system of input , voltage range 110V AC +_ 5% frecuency range 40HZ 60HZ, power fector >_ 0.90 @ full load, and output voltage range 200V/208V/220V/230V/240V/ AC voltage regulation +_ 1% frequancy range 50Hz +_ 0.25Hz or 60Hz +_ 30Hz harmonic distrortion -< 2% THD (Liner load ) 4% THD ( non linier load ) efficency -88/83%
Earthing with copper . Earth plate 600 mm x 600 mm x 3 mm thick including accessories and providing masonary enclosure with cover plate having locking arrangement and watering pipe etc.( with charcoal or coke and salt).
Earthing with G.I. Earth plate 600 mm x 600 mm x 6 mm thick including accessories and providing masonary enclosure with cover plate having locking arrangement and watering pipe etc. ( with charcoal or coke and salt).
Supply and laying 32mmX5 MM GI strip at 0.50 meter below ground as strip earth electride including soldering etc as required
Supply and laying 32mmX6 MM GI strip at 0.50 meter below ground as strip earth electride including soldering etc as required
Providing and fixing 25 mm X 6 mm GI strip on surface or in recess for down conductor for lightning system. as required.
Providing and fixing 25mm X 3mm G.I. strip on surface or in recess on Terrace for Lightning etc. as required.
Providing and fixing 25 mm X 5 mm copper strip on surface or in recess for connections etc. as required.
Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required.
Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing as required.
Providing and fixing of Single core 35 sqmm dia Cu. Green colour cable.
Providing and fixing of Single core 16 sqmm dia Cu. Green colour cable.
Supply ans laying of GI pipe under road/paved area crossing etc. including excavation back filling ramming and making good.
100mm Dia pipe
150mm Dia pipe
Providing and fixing earth bus of 50mmX 5mm copper strip on surface for connections etc. as required, Impulse current (10/350 micro sec) = 103 KA, Charge (Q) = 54.9 A.s, Specific Energy (W/R) = 2.5 MJ/Ω.
EXTERNAL LIGHTING
Supply of following sizes sizes of PVC insulated PVC sheathed aluminium conductor armoured 1.1 KV grade as as required. 2C x 6 sq mm
Laying of one number additional PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of size not exceeding35 sq mm direct in ground in same trench in one tier horizontal formation including excavation, sand cushioning, protective covering and refilling the trench etc as required.
Laying of one number additional PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of size not exceeding 185 sq mm but not exceeding 400 sq mm direct in ground in same trench in one tier horizontal formation including excavation, sand cushioning, protective covering and refilling the trench etc as required.
Laying of one number additional PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of size not exceeding 95 sq mm but not exceeding 185 sq mm direct in ground in same trench in one tier horizontal formation including excavation, sand cushioning, protective covering and refilling the trench etc as required.
Supplying and making end termination of following sizes with brass compression gland including providing and crimping solderless plugs/ferrules of sizes PVC insulated PVC sheathed aluminum conductor armoured cable 1.1 KV grade. 2C x 6 sq mm
Supplying and laying 6 SWG G.I. wire at 0.50 metre below ground level for conductor earth electrode, including soldering etc as required
Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc with out charcoal/coke and salt as required
Supplying and fixing 50mm dia GI pipe on the pole for cable entry to junction box as required.
DG SETS and BATTERY CHARGER: - Supply, installation, testing and commissioning silent type D.G set of 400 KVA, with AMF panel IS/IEC-60034-1 at 0.8 P.F. (lagging), aircooled radiator type diesel engine alternator set mounted on common base frame complete with accessories as per specification and layout, drawing with battery charger, battery and battery rack residential silencer, stainless steel bellows, 990 Ltrs. day fuel tank, spring loaded GERB cush pads, logic control panel, governor etc including Accoustic Enclosure suitable for intdoor installation complete as required.
Supply, installation, testing and commissioning silent type D.G set of 125 KVA, with AMF panel IS/IEC-60034-1 at 0.8 P.F. (lagging), aircooled radiator type diesel engine alternator set mounted on common base frame complete with accessories as per specification and layout, drawing with battery charger, battery and battery rack residential silencer, stainless steel bellows, 990 Ltrs. day fuel tank, spring loaded GERB cush pads, logic control panel, governor etc including Accoustic Enclosure suitable for intdoor installation complete as required.
Supply, laying of following sizes of MS Piping for Exhaust including providing suitable bends, reducers & supporting arrangement at suitable intervals including insulation on entire length of exhaust pipe with 50mm thick Rockwool insulation & painting etc. as required.
200mm (NB) MS ERW pipe
125mm (NB) MS ERW pipe
SANITARY FIXTURES & CP FITTINGS:
Supplying, fitting and fixing 40mm high vitreous white glazed earthen E.W.C. with ‘p’ trap of parry hindustan or any other approved I.S.S. make including supplying and fixing 15 litres C.I. mosquito proof low down flushing cistern of approved make with complete fittings with C.I.handle and R.S. or bracket with telescopic flush pipe with brass coupling and plumbers joints spindle stop cock of approved quality weight not less than 450grams 15mm P.V.C. alkathene pipe 45cm. long with brass coupling at both ends and white/black plastic solid state seal and lead of commander/cuckoo or other I.S.S. make with hinges or screws etc. painting pipe and cistern etc. with 2 coats of approved paint over a coat of red oxide priming, all complete as per specification and direction of E/I. (ii) E.W.C. with 'S' trap. (a) 12.5 lit low level PVC Cistem
Supplying, fitting and fixing flat back or angular, lipped front vitreous white glazed earthen ware urinal of ‘Hindustan "Parry" or any other approved I.S.S make with 5 liters capacity C.I. automatic fulsing cistern of reliance for any other I.S.S. approved make with all fittings with C.I.or R.S. brackets, standard size G.I. flush pipe with fitting clamps,15mm C.I. body brass spindle stop cock of approved quality weight not less than 400grams, 15mm P.V.C./Alkthene pipe 450mm longwith brass coupling at both ends and doing plumber joints including painting of exposed part with two coats of approved paint over a priming coat of red oxide, cutting wall and floor, making good the same etc. all complete as per specification and direction of E/I. (a) Flat back or standing comer (600×350mm )
Supplying fitting and fixing vitreous white glazed earthen ware wash hand basin of parry or Hindustan or any other I.S.S. approved make supported on painted C.I. or R.S. brackets 32mm C.I.brass waste, 15 mm dia C.I. body brass spindle stop cock of approved quality of weight not less than 350grams, 32mm P.V.C. waste pipe 750mm long with brass coupling at one end and making plumber joints etc. all complete as per specification and direction of E/I.
Supplying fitting and fixing white glazed fire’s clay sink of approved make with overflow arrangements supported on C.I. or R.S. painted brackets 40mm. dia C.P.brass waste with C.P.brass chain and rubber plug 40 mm dia P.V.C. waste pipe about 750mm long with brass coupling at one endand 15mm C.I. body brass spindle bib cock of approved quality of weight not less than 450grams. including cutting wall and making good the same etc. all complete as per specification and direction of E/I. Kitchen sink 600mm ×450mm×250mm.
Providing & fixing PVC waste pipe for sink including PVC waste fitting Complete. Flexible Pipe, 32mm Dia.
Providing and fixing PTMT Bottle Trap for Wash basin. Bottle trap 31 mm single piece moulded with height of 270 mm, effective length of tail pipe 260 mm from the centre of the waste coupling 77 mm breadth with 25 mm minimum water seal, weighing not less than 260 gms.
Providing and fixing male ended 15mm dia brass bib cock of approved quality (Wt. not less than 350gms.) with extra socket all complete as per specification and direction of E/I.
Providing and fixing C.P. brass long body bib cock of approved quality conforming to IS standards and weighing not less than 690 gms. 15 mm nominal bore
Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS 8931 a) 15 mm nominal bore. 15 mm nominal bore
Providing and fixing uplasticised PVC connection pipe with brass unions : 45 cm length, 15 mm nominal bore
Providing and fixing toilet paper holder : C.P. brass
Providing & Fixing PTMT liquid soap container 109 mm wide, 125 mm high and 112 mm distance from wall of standard shape with bracket of the same material with snap fittings of approved quality and colour, weighing not less than 105 gms
Providing and fixing lead connection pipe with heavy quality brass coupling 2 nos. at both ends etc all complete as per specification and direction of Engineer-in-charge. 15 mm dia and 45 cm long,
Providing and fixing 15 mm size CP brass pillar cock (Weight not less than 350gms) C I body brass spindle pillar cock of approved quality as per specification and directionof Engineer-in-Charge. C.I body brass spindle.
Supplying fitting and fixing the following items complete with all materials as per specification and directionof E/I. (a) Glass shelf with C P brass rail, (i) 600×125 mm glass shelf complete
(b) Mirrors of 6mm thick plate glass bevelled edge mirror including C.P. brass revolving fittings 3mm ply wood board and C.P. hinges to fix with mirror.
(I) 600 mm×450 mm size
(c) (III) C P brass liquid soap container
Providing and Fixing in position Hindware make or equivalent CP Grab Bar with wall flanges 600 mm to wooden cleats with C.P. brass screws complete in all respects.
Providing, Fixing, testing and commissioning of C.P. brass wall/counter mounted Single Lever sink mixer with C.P. wall flange, overhead swinging spout/goose neck complete as required and making good Including necessary wall cutting / chasing and making good, as required of make parryware diamond range or equivalent as per direction of Engineer in Charge.
Supply and fixing HINDWARE make or equivalent Health Faucet with 8 mm dia, flexible tube with wall hook and Angle stop cock with wall flange . Etc all as directed by Engineer In-Charge.
Providing and Fixing in position best HINDWARE make Vitreous Chinaware partition slab for urinals, size 690X165X325mm, all as specified and directed.
Providing, Installing & fixing storage type water heater of approved shade with copper container, glasswool insulation,stove enamelled M.S jacket, thermostatically controlled inner heater with pilot neon lamps, 15mm inlet stop cock valve, on inlet connection, 15mm dia C.P flexible connection pipe in inlet & outlet suitable for working pressure of 8 kg/sqcm complete as required. Capacity 25 litres.
INTERNAL DRAINAGE (SOIL, WASTE,VENT & RAIN WATER DISPOSAL PIPES FITTINGS):
Providing, Fixing, testing and commissioning of UPVC pipe SWR type 'B' conforms to IS : 13592-1992 with all fittings such as bends, tees, elbow, 'Y', offset, cleaning pipe door, clamps and steel structural supports etc. including cutting the floors, walls and making good the same in cement concrete 1:2:4 & cement mortar 1:4. The wall thickness of pipe and technical characteristic conforms to IS : 13592-1992 type 'B'. The fitting dimension conforming to IS : 14735-1999. The jointing to be completed with rubber ring joint/solvent weld joint.
90 mm (OD) SWR Pipe
110 mm (OD) SWR Pipe
160 mm (OD) SWR Pipe
Providing, Fixing and laying cement concrete 1:2:4 mix (1 cement :2 coarse sand :4 graded stone aggregate, 20 mm down gauge) 75 mm in bed and all around UPVC waste pipes under floor, including shuttering and necessary reinforcement etc. complete as required for: - 100 mm dia
Providing, Fixing, testing and commissioning of UPVC 'P' trap/floor trap/urinal trap of self cleansing design with or without horn conforming to IS : 14735-1999 including setting with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 hard stone ballast 20 mm nominal size) cutting and making good the walls & floors.
110 mm (OD) x 110 mm (OD)
Providing, Fixing, testing and commissioning of UPVC cleanout plug conforming to IS : 14735-1999 complete with all fitting; accessories and civil work.
Providing, Fixing, testing and commissioning of UPVC waste Pipe conforming to IS : 4985-2000 class IV (6 Kg/Sq.cm) including all moulding fittings conforming to IS : 7834 (Part-1 - Part -7) 1987 such as tees, bends, reducers, coupling, adopters etc. solvent welded joint as per manufacturer recommendation including cutting and making good the walls, floors, R.C.C. work etc. (For waste connection)
Providing, Fixing UPVC floor drain including all fitting and accessories fixed in cement mortar complete in all respect. 110 mm OD x 63 mm OD
Providing, Fixing, testing and commissioning of UPVC inlet fittings with maximum 3 inlets 40, 50 & 63 mm OD size UPVC sockets, fixed to CI/UPVC traps including solvent weld joint/rubber ring joint complete with all civil work.
Providing and fixing PTMT grating of approved quality, colour and make 125 mm nominal dia with 25 mm waste hole
Providing and fixing straight/offset type flexible single body push fit type WC Pan Connector with factory supplied spring loaded seal guard with integrated single mould sealing fins made of flexible EVA Body, including bush/adaptor for use with CI Pipe as supplied with Pan Connector (For European water closet).
Providing and fixing in position stainless steel cockroch trap consisting of 0.45 mm thick inner and outer cup and 1.00 mm thick top grating (Jali) with ring to be fixed inside C.I. or uPVC ‘P’ traps with cement concrete.
RAIN WATER DISPOSAL :
Making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate of 20 mm nominal size) over P.V.C. sheet 1 m x1 m x 400 micron, finished with 12 mm cement plaster 1:3 (1 cement : 3 coarse sand) and a coat of neat cement, rounding the edges and making and finishing the outlet complete.
Providing and fixing on wall face unplasticised - Rigid PVC rain water pipes confirming to IS : 13592 Type A including jointing with seal ring confirming to IS : 5382 leaving 10mm gap for thermal expansion and with all fittings such as bends, tees, elbow, 'Y', offset, cleaning pipe door, clamps and steel structural supports etc. including cutting the floors, walls and making good the same in cement concrete 1:2:4 & cement mortar 1:4. The wall thickness of pipe and technical characteristic conforms to IS : 13592-1992 type 'B'. The fitting dimension conforming to IS : 14735-1999. The jointing to be completed with rubber ring joint/solvent weld joint.
Providing and laying cement concrete 1:2:4 mix (1 cement :2 coarse sand :4 graded stone aggregate, 20 mm down gauge) 75 mm thick in bed and all around UPVC pipes under floor, including shuttering and centering for: - 160 mm dia
Providing and fixing to the inlet mouth of rain water pipe cast iron grating 15cm diameter and weighting not less than 440 grams.
Providing and fixing 3 layer PP-R (Poly propylene Random copolymer) pipes confirming to IS:15801, UV stabilized & anti - microbial fusion welded, having thermal stability for hot & cold water supply, including all PP - R plain & brass threaded polypropylene random fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer-in-Charge. Concealed work,including cutting chases and making good the wall etc
PN - 16 Pipe, 20mm OD (SDR-7.4)
PN - 16 Pipe, 25mm OD (SDR-7.4
PN - 16 Pipe, 32 mm OD (SDR-7.4
Providing and fixing 3 layer PP-R (Poly propylene Random copolymer) pipes confirming to IS 15801, UV stabilized & anti - microbial fusion welded, having thermal stability for hot & cold water supply, including all PP - R plain & brass threaded polypropylene random fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes testing of joints complete as per direction of Engineer-in-Charge. Internal Exposed on walls.
PN - 16 Pipe, 20mm OD (SDR-7.4)
PN - 16 Pipe, 25mm OD (SDR-7.4)
PN - 16 Pipe, 32mm OD (SDR-7.4)
PN - 16 Pipe, 40mm OD (SDR-7.4)
PN - 10 Pipe, 50mm OD (SDR-11)
PN - 10 Pipe, 63 mm OD (SDR-11)
Providing and fixing PPR Unions
PPR Union 20 mm
PPR Union 25 mm
PPR Union 32 mm
PPR Union 40 mm
PPR Union 50 mm
PPR Union 63 mm
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes,having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. 62.5 mm nominal OD
Thermal Insulation on CPVC Pipe Embedded in Wall: = Providing & fixing thermal insulation on hot water pipes a flexible electomeric foam of closed cells structure having thermal conductivity of 0.038 W/M.K at 40o C, water vapour permeability fire propagation including all accessories e.g. adhesive and ape on joint complete as per specification. All joints shall be sealed with adhesive & cotton tape.
15.9 mm (OD) [6mm thick insulation]
22.2 mm (OD) [6mm thick insulation]
28.6 mm (OD) [6mm thick insulation]
Providing and fixing Gun metal full way valve of approved qualtiy, all complete as per specification and direction of E/l
(a) 15 mm dia wt not less than 300 gms
(a) 20mm dia wt not less than 400 gms
(a) 25 mm dia wt not less than 500 gms
(a) 32 mm dia wt not less than 700 gms
(a) 40 mm dia wt not less than 1kg
Providing and fixing forged brass auto air vent valve PN10 (10.00 Kg/cm2) rating including all fitting with ball valve & accessories. 15 mm dia
Butterfly Valves :: - Providing, fixing, testing & commissioning of wafer type cast iron butterfly valves conforming to BS 5155 & IS 13095 tested to 15 Kg/Sq.cm pressure for maximum working pressure of 10 bar (PN 10) including all fitting and accessories (Drain, water meter for OH Tank/Riser).
50 mm dia
65 mm dia
EXTERNAL WATER SUPPLY:
Excavating trenches of required width for pipes including excavation for sockets also including for cement concrete craddles, and dressing of sides, ramming of bottoms, depth up to 1.5m including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20 cm in depth including consolidating each deposited layer with minimum 95% by ramming, watering etc. and disposing off surplus excavated soil as directed, within a lead of 50 m. UPTO 1.5M Pipes, cables etc, not exceeding 80 mm dia.
Providing and fixing G.I. pipes complete with G.I. fittings including trenching and refilling etc. [Location : From Bore Well/Tanker water supply line/Municipal line to Underground Water Storage Tank]. 80 mm dia
Sluice Valve :- Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) : 80 mm dia
DUAL PLATE NON RETURN VALVE : - Providing and fixing gun metal non- return valve of approved quality (screwed end) : 80 mm dia Horizontal
Providing and fixing enclosed type water meter (bulk type) conforming to IS : 2373 and tested by Municipal Board complete with bolts, nuts, rubber insertions etc. (The tail pieces if required will be paid separately) : 80 mm dia
Providing and fixing C.I. dirt box strainer for bulk type water meter with nuts, bolts, rubber insertions etc. complete conforming to IS : 2373 : 80 mm dia
Constructing masonry Chamber 60x45x50 cm inside, in brick work in cement mortar 1:4 (1 cement : 4 coarse sand) for water meter complete with C.I. double flap surface box 400x200x200 mm (inside) with locking arrangement and RCC top slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) , i/c necessary excavation, foundation concrete 1:5:10 ( 1 cement : 5 fine sand:10 graded stone aggregate 40 mm nominal size) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12 mm thick, finished with a floating coat of neat cement complete as per standard design : With common burnt clay F.P.S.(non modular) bricks of class designation 7.5
Providing and fixing C.I. double acting air valve of approved quality with bolts, nuts, rubber insertions etc. complete (The tail pieces, tapers etc if required will be paid separately) : 80mm dia
EXTERNAL SEWERAGE :
Constructing water tight brick masonry grease trap with first class bricks in cement mortar 1:6 (1 cement :6 coarse sand), R.C.C. top slab with 1:2:4 mix (1 cement :2 coarse sand :4 graded stone aggregate 20 mm nominal size, foundation concrete 150 mm thick 1:4:8 (1 cement :4 coarse sand :8 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement :3 coarse sand) finished with a floating coat of neat cement & M.S. foot rests including fixing in 20 x 20 x 10 cm cement concrete blocks 1:3:6 (1 cement :3 coarse sand :6 graded stone aggregate 20 mm nominal size), two brick masonry baffle walls each of 500 mm depth deep each of 115 mm thickness, 2 Nos C.I. double seal medium duty covers each of 450 x 450 mm size including excavation, backfilling & disposal of surplus earth with a lead upto 50m complete as per standard design. (Note: Cost shall include dewatering & water proofing of Grease trap as directed at site). Grease Trap (Size 1200 x 900 x 1000 mm overall depth).
Providing & laying S & S cast spun pipes conforming to IS : 1536 class 'LA' including all fittings conforming to IS : 1538 e.g. bends, tees, reducers, blank flanges, tyton joints as per IS : 3114, effective proper connection (For External Sewer Line + Bypass line from Equalization tank to municipal sewer) complete i/c excavation/back filling, bed concrete, sand bed, painting two or more coats with synthetic enamel paint over a coat of primer. 100 mm dia
STORM WATER DRAINAGE:
Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. All kinds of soil.
Earth Work in Excavation of required width for storm water drainage pipes including excavation for sockets and dressing of sides, ramming of bottom depth upto 1.5 m including getting out the excavated soil and then returning the soil as required in layer not exceeding 20 cms in depth including consolidating each deposited layers by ramming, watering etc. and disposing of surplus excavated soil as directed within a lead of 50 m for all kinds of soil. Pipes, exceeding 80 mm dia but not exceeding 300 mm dia.
Extra for excavating trenches for pipes, cables etc in all kinds of soil for depth exceeding 1.5m, but not exceeding 3m. (Rate is over corresponding basic item for depth up to 1.5 metre Pipes, exceeding 80 mm dia but not exceeding 300 mm dia.
Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth,consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.
12 mm cement plaster of mix : 1:4 (1 cement: 4 fine sand)
Providing, laying and jointing light duty non-pressure NP2 class S/S R.C.C. pipes with collars jointing with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including curing, testing of joints etc. 250 mm dia
Providing and laying cement concrete 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size) up to haunches of S.W. pipes including bed concrete as per standard design : 250 mm dia.
CATCH BASIN CHAMBER FOR STORM WATER:
Constructing brick masonry road gully chamber 50 x 45 x 60 cm unit brick of class designated 75 in cement mortar 1:4 (1 cement :4 coarse sand) including 500 x 450 mm precast RCC horizontal grating with frame complete as per standard design. With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
Constructing brick masonry circular type manhole 0.91 m internal dia at bottom and 0.56m dia at top in cement mortar 1:4 (1 cement : 4 coarse sand), in side cement plaster 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with a floating coat of neat cement outside rough cement plaster 15 mm thick with CM 1:3 (1 cement:3 coarse sand), foundation concrete 1:3:6 mix (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size), and making necessary channel in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) finished with a floating coat of neat cement all complete as per standard design. With F.P.S. bricks class designation 75.
Extra depth for circular type manhole 0.91m Internal dia (at bottom) with beyond 0.91 m to 1.67m. With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
Providing orange colour safety foot rest of minimum 6 mm thick plastic encapsulated as per IS : 10910 on 12 mm dia steel bar conforming to IS : 1786 having minimum cross section as 23 mm x 25 mm and over all minimum length 263 mm and width as 165 mm with minimum 112 mm space between protruded legs having 2 mm tread on top surface by ribbing or chequering besides necessary and adequate anchoring projections on tail length on 138 mm as per standard drawing and suitable to with stand the bend test and chemical resistance test as per specifications and having manufacture's permanent identification mark to be visible even after fixing, including fixing in manholes with 30 x 20 x 15 cm cement concrete block 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) complete as per design.
Providing and fixing M.S fabricated epoxy coated(two layers) galvinised coating puddle flange comprising of 600 mm dia long M.S class 'C' pipe (screwed end up to 50 mm & flange for more than 50 mm dia) with 6 mm thick M.S plates of required size upto 150 mm dia & 7.1 mm thick mm plate for pipe dia above 150 mm dia including cutting holes in centre of plate, inserting pipe & making welded (Arc) joint complete. Same shall be installed with TEC welded joint in position with reinforcement bars of RCC tank wall/slab including making cutout in shuttering during concrete casting of tank of following diameter. (Location: underground/ overhead tanks.)
25 mm dia
50 mm dia
65 mm dia
80 mm dia
100 mm dia
200 mm dia
Providing and placing on terrace storage tank ISI : 12701 marked indicating the BIS License No. with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank [Sintex, Electroplast, Star, Lotus or equivalent having valid ISI license].
Providing and fixing G.I. Vent Pipe class 'B' (medium duty) for R.C.C water storage tanks comprising of 600 mm long vertical pipe, return bend with mosquito grating & cast brass perforated coupling including all associated civil work. 100 mm dia
Providing and fixing of mosquito overflow grating /Jali of the following diameters including all fitings & accessories :- 100 mm dia
Water Supply, Drainage Pumps & Water Treatment Equipments
Supply, installation, testing & commissioning of vertical inline multistage pumping set (Imported) with Stainless steel body, impeller, casing, shaft and C.I. base & head with mechanical seal, connected to a TEFC induction motor suitable for 415+/- 10% volts, 3 phase 50 cycles A.C. supply with 150 mm dia pressure gauge with gunmetal isolation cock, vibration eliminating pads under foundations, 80x40 mm I section base plate bolted to cement concrete foundations complete.Vendor to submit performance curves and technical catalogue of the proposed model for review and information. Filter Feed Pump (Dom. Water) at Water Supply Pump Room : - Set of Two Pumps (1 Working+ 1 Standby), Capacity - 2.0 LPS, Head - 25 M., HP - 2.0 HP Approxi, Head - 25 M,
Raw Water Transfer Pump to STP at Pump Room: - Set of Two Pumps (1 Working+ 1 Standby), Capacity - 1.0 LPS, HP - 1.0 HP Approxi.
Irrigation Pump at STP Pump Room : - Set of Two Pumps (1 Working+ 1 Standby), Capacity - 4.0 LPS, Head - 40 M., HP - 5.0 HP Approxi.
Providing, installing, testing and commissining of fixed speed hydropneumatic system mounted on a common base plate comprising of vertical centrifugal pumping set with S.S body, stainless steel impeller and mechanical seal, shaft directly coupled to a TEFC induction motor suitable for 400/440 volts, 3 phase, 50 cycles AC supply with 150 mm dia pressure gauge with gunmetal isolation cock, vibration eliminating pads under foundation, one No. microprocessor based controller, one No.remote sensors, pressure transducers, sequence running cotroller, dry running Protection,motor control centre, necessary power and control cabling from MCC to pumps including required rating of MCB, one No. 100 litre capacity M.S diaphragam tank with interchangeable butyl rubber membrane,complete in all respects, including stainless steel grade 316 pipe suction and delivery headers and isolation/ control valves( ball valves/butterfly valves/ Nan return valves/ vibration eliminators etc as required) , power box, equipped with fuses/ isolators/circuit breakers as required.
Hyd. System for Domestic Water Supply at Water Supply Pump Room l - Set of Two Pumps (1 Working+ 1 Standby), Capacity - 2.5 LPS, Head - 45 M., HP - 3.0 HP Approxi.
Hyd. System for Flushing Water Supply at STP Pump Rm - Set of Two Pumps (1 Working+ 1 Standby), Capacity - 1.5 LPS, Head - 45 M., HP - 2.0 HP Approxi.
Supply, installing, testing and commissioning of submersible open impeller non-clog pumps with C.I.body and to TEFC submersible motor for 415 + 10% volts, 3 phase, 50 cycles A.C. power supply with mechanical seal, pump connector unit with rubber diaphragm and bend, vertical discharge pipe, guide pipe and chain in built level controller, sequence running controller, arrangement for both pumps together inacase of emenegency, audible hooter for failure or flooding, dry running Protection complete in all respects., painting, testing and commissioning complete with approved quality and make as required as per instruction of site incharge. (Pumps shall be installed in a set of two pumps One working and One standby). Basement & Pump Room Drainage Pumps: - (Pumps to be suitable to handle solids upto 30 mm size) Capacity - 4.0 LPS (Each), Head - 15 M., HP - 1.5 HP Approxi.
Supply Installation,Testing & Commissioning of vertical self supporting Filter fabricated from MS sheet as per IS: 2825, ((minimum thickness of shall 6 mm and dished end 8 mm)) pressure gauges, sample cock, GI class 'C' face piping, CI butterfly valves and all accessories , with initial charge of filter media including anthracite, painting inside with epoxy paint and outside with two coat of red oxide primer and two or more coat of synthetic enamel paint, testing and commissioning complete.
Dual Media Filter For Domestic Water Supply: Capacity - 7200 LPS, Filtration rate- 14000 LPH/Sqm, Filter dia approx. - 1000 MM, Working pressure: 3.0 Kg/sq cm. ,Test pressure : 4. 5 Kg/sq cm.
Activated Carbon Filter For Domestic Water Supply : Capacity - 7200 LPS, Filtration rate- 14000 LPH/Sqm, Filter dia approx. - 1000 MM, Working pressure: 3.0 Kg/sq cm. ,Test pressure : 4. 5 Kg/sq cm.
Supply Installation,Testing & Commissioning of metering pump type chemical doser with 100 lits. HDPE chemical grade solution tank,injection fitting assembly,suction and delivery hose upto the point of injection, capacity 0-6 lph, complete in all respects. Chlorination of Domestic Water.
Design, manufacture, supplying, fixing in position, testing and commissioning of the following front operated cubicle type, front access 2mm thick mild steel sheet, free standing, dust and vermin proof, switchboard with IP42 protection with hinged and lockable doors complete with interconnections, tinned copper crimping lugs, bonding to earth and painting, suitable for use at 415 volts, 3 phase 4 wire 50 Hz system and suitable for a fault level of 25 MVA symmetrical at 415 volts. All switchboards shall have provision for entry of cables from the top or bottom as required. All live accessible parts shall be shrouded and all equipment shall be finger touch proof. The busbars insulation shall be with heat shrinkable sleeves. SMC/DMC shrouds and busbar supports shall be used. Padlocking facility shall be provided on all outgoing feeders doors and switch handles shall be lockable in OFF position.
Supplying, installing, testing and commissioning controllers with low voltage relays, stainless steel probes and PVC shroud wiring from tank top to problems of required.
For Water Supply Pump: - To start pump when water level is low in Domestic Water U.G. tank and shut off pump when Domestic Water U.G. tank is full. Also to stop when water level is low in raw water underground tank.
For Sump Pumps:: - To start pump when water level is high in sump and shut off pump when sump is empty. Both pumps are start when sump is over flowing.
Providing and fixing GI pipes complete (IS:1239 Heavy Class) with GI fittings and clamps including MS pipe supports, enamel paint as per specifications cutting and making good the walls etc. complete.
50 mm dia
65 mm dia
80 mm dia
100 mm dia
Providing & fixing butterfly valve tested to a pressure not less than 25 Kg/Sq.cm. Including rubber gasket, 2 nos. Table-E flanges, nuts, bolts, washers & painting complete as required.
50 mm dia
65 mm dia
80 mm dia
100 mm dia
Providing & fixing dual plate CI wafer type check valve tested to a pressure of 25 Kg/sqcm. Including rubber gasket, 2 nos. table-E flanges, union, nuts, bolts, washers & painting complete as required.
50 mm dia
65 mm dia
80 mm dia
Providing and fixing resilient rubber neoprene lined style arch vibration eliminators suitable for raw water upto 45 deg.C. Temperature working pressure upto 25 Kg/Sqcm.
50 mm dia
65 mm dia
Providing and fixing heavy duty armoured cables 1.1 KVA grade including necessary support clamps at ceiling level and connection lugs complete in all respects.
Power cable Copper 3 core 10 sq.mm
Power cable Copper 3 core 6 sq.mm
Power cable Copper 3 core 4 sq.mm
Control cable copper 2 core 1.5 sq.mm
Providing and fixing CI Y type suction strainer with gunmetal or brass internal parts installed outside water tanks. 100 mm dia.
Sewage Treatment Plant
Supplying, installation, testing & commissioning of Sewage Treatment Plant for the following duty:
Daily average flow - 50 cum/day
Nature of effluent - Sewage
Influent Characteristics considered for design
BOD5 - 250-300 mg/liter
S. Solids - 250-300 mg/liter
COD - 400-600 mg/liter
Oil & Grease ` - <50 mg/liter
After tertiary treatment
BOD5 - 10 mg/liter
S. Solids - Less than 10 mg/liter
COD - Less than 50 mg/liter
Oil & Grease - upto 5 mg/l
Color - As per norms
odor - As per norms
Primary Treatment
Supply, installation, testing & commissioning of Screens
2 Nos.Mild Steel Suitable Sized Manually operated Bar Screen made of MS in RCC screen channel as per following specifications
Cleaning :- Manual Screen
MOC :- Complete in MS
Supply, installation, testing & commissioning of Raw sewage Transfer pumps with suitable solid handling capacity with CI casing & CI impeller complete with all accessories, motor of required capacity. Pumps shall have following duty:
Pumps = 02 Nos.(1w + 1s)
Flow rate (each) = 5 m³/hr
Head = 8-10 m
Make = Wilo/KSB/Eqv.
Piping and accessories
Providing and fixing all piping of required MOC as MS/UPVC and isolation control valves for making the system complete.
Supply, installation, testing & commissioning of adequate capacities of Coarse air diffusers for providing aeration.
Location : For Equalization tank and Sludge holding tank
Biological Treatment
The break up of equipments of MBBR Package
Air Blowers For MBBR Tank, EQT and SHT tank
Capacity : App 60 m3/hr.@5500 mmwc
Type: Twin Lobe
Qty. 2 Nos. (1 w+1s)
Fine Bubble Diffusers
Type : Tubular type
Length : 600mm long
Qty-1 Lot
MBBR Media
Qty -1 Lot
Make: PS Aqua Pvt. Ltd./GWESPL
Tube deck Media
Qty -1 Lot
Make: PS Aqua Pvt. Ltd./GWESPL
Pipes and fittings for Air piping and Air Grid
Qty-1 Lot
Level transmitter/controller and accessories
Qty-1 Lot
Tertiary Treatment
Supplying, installing, testing, commissioning of Centrifugal Filter Feed Water pumps complete with motor and all other accessories required to complete the system
Pumps = 02 Nos.(1w + 1s)
Flow rate (each) = 2.5 m³/hr
Head = 25-30 m
Make: Kirloskar/Eqv.
Supplying, Installation, testing and commissioning of Chemical dosing system comprising of Sintex Tank with inlet/ outlet connection, piping and valves along with metering pump of 0-6 LPH for dosing.
Supplying, installation, testing & commissioning of FRP vessel filter with frontal piping and Valves with all the required accessories. Filter shall include media, standard fittings like pressure gauges, sampling cock, rinse drain.
Multi Grade Sand Filter
HOS: 1625 mm
Filter media: Fine Sand, pebbles ,gravels and activited carbon
Make: PS Aqua/GWESPL
Activated Carbon Filter
HOS: 1625 mm
Filter media: Activated Carbon, Fine Sand, pebbles ,gravels.
Make: PS Aqua/GWESPL
Sludge Dewatering system
Supply, installation, testing & commissioning of Sludge transfer pumps for sludge Transfer to sludge holding tank complete with all the accessories, motor of required capacity.
Pumps = 02 Nos.(1w + 1s)
Flow rate (each) = 0.5 m³/hr
Head = 8-10 m
Make - Kirloskar/Eqv
Supply, installation, testing & commissioning of Sludge feed pumps ( for sludge Feeding to Sludge Bag) complete with all the accessories, motor of required capacity.
Pumps = 02 Nos. (1w+1s)
Flow rate (each) = 1 m³/hr
Head = 8-10 m
Make - Kirloskar/Eqv
Supplying, installing, testing, commissioning of Sludge Bag of suitable size for the dewatering of sludge generated per day
Providing & fixing on line full bore type Magnetic flow meter with preamplifier & microprocessor based electronic flow meter mounted in plumbing plant room electrical control panel with the following features. Monitoring the total flow, Flow rate, etc. Including electrical wiring from preamplifier to microprocessor based flow meter. Complete with all type of Plumbing & Electrical connections, accessories, wiring, conduits & supports complete with all respect. The signal from read out shall be 4-20 m.amps to be received as BAS.
ELECTRICALS
FIRE PROTECTION
Supplying, installation, testing and commissioning of electric driven pressurisation pump suitable for automatic operation and consisting of following, complete in all respects, as required : (Jockey Pump) Horizontal type, multistage, centrifugal, split casing pump of cast iron body & bronze impeller with stainless steel shaft, mechanical seal conforming to IS 1520. Suitable HP Squirrel cage induction motor, TEFC, synchronous speed 1500 RPM, suitable for operation on 415 volts, 3 phase 50 Hz, AC supply with IP 55 protection for enclosure, horizontal foot mounted type with Class-'F' insulation, conforming to IS-325. M.S. fabricated Common base plate, coupling, coupling guard, foundation bolts etc. as required. Suitable cement concrete foundation duly plastered with anti vibration pads. 180 lpm at 88 m Head.
Providing, laying, testing & commissioning of 'C' class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required :
25 mm dia
32 mm dia
40 mm dia
50 mm dia
65 mm dia
80 mm dia
100 mm dia
150 mm dia
Providing, laying, testing & commissioning of 'B' class heavy duty G.I. pipe conforming to IS 1239 including welding, fittings like elbows, tees, flanges, tapers, nuts, bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required :
50 mm dia
80 mm dia
Supplying and fixing single headed internal hydrant valve with instantaneous Gunmetal/Stainless Steel coupling of 63 mm dia with cast iron wheel ISI marked conforming to IS 5290 (Type -A) with blank Gunmetal/Stainless Steel cap and chain as required :. Single headed Stainless steel
Supplying and fixing Single headed external yard hydrant valve with 1 No. 63 mm dia instantaneous FM Gunmetal/Stainless Steel coupling and cast iron wheel, ISI marked, conforming to IS 5290 (type A) with blank Gunmetal/Stainless Steel cap and chain as required :. Single headed Stainless steel
Supplying, fixing, testing and commissioning of butterfly valve of PN 1.6 rating with bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13095 of following sizes as required :
50mm dia
65 mm dia
80 mm dia
100 mm dia
150 mm dia
Supplying and fixing orifice plate made out of 6 mm thick stainless steel (Grade 304) with orifice of required size to be fitted between flange & landing valve of external and internal hydrants to reduce pressure at the outlet to the level of 3.5 kg/cm2 complete as required.
Providing, installation, testing and commissioning of non-return valve of following sizes confirming to IS: 5312 complete with rubber gasket, GI bolts, nuts, washers etc.as required :
65mm dia
80mm dia
100mm dia
150mm dia
250mm dia
Providing, installation, testing and commissioning of stainless steel Y-strainer fabricated out of 1.6 mm thick stainless steel, Grade 304, sheet with 3 mm dia holes with stainless steel flange.. 200 mm dia
Supplying and fixing 63 mm dia, 15 m long RRL hose pipe with 63 mm dia male and female couplings duly bound with GI wire, rivets etc. conforming to IS 636 (type-A) as required :. Stainless Steel (Grade 304)
Supplying and fixing first-aid Hose Reel with MS construction spray painted in post office red, conforming to IS 884 complete with the following as required. 20 mm nominal internal dia water hose thermoplastic (Textile reinforced) type -2 as per IS: 12585. 20 mm nominal internal dia gun metal globe valve & nozzle. Drum and brackets for fixing the equipmets on wall. Connections from riser with 25 mm dia stop gun metal valve & M.S. Pipe and socket. . 30 m
Supplying & fixing 63 mm dia gun metal short branch pipe with 20 mm nominal internal diameter size nozzle conforming to IS 903 suitable for nstantaneous connection to interconnect hose pipe coupling as required :. Stainless Steel (Grade 304)
Supplying and fixing of fire brigade connection of cast iron body with gun metal male instantaneous inlet couplings complete with cap and chain as reqd. for suitable dia MS pipe connection conforming to IS 904 as required :
2 way-100 mm dia M.S. Pipe
4 way - 150 mm dia M.S. Pipe
Supplying and fixing air vessel made of 250 mm dia, 8 mm thick MS sheet, 1200 mm in height with air release valve on top and flanged connection to riser, drain arrangement with 25 mm dia gun metal wheel valve with required accessories, pressure gauge and paintingwith synthetic enamel paint of approved shade as required.
Providing, fixing, testing & commissioning of 15mm dia quartzoid bulb type sprinklers of rating 68 degree centigrade with required accessories :
Pendent Sprinkler
Upright Sprinkler
Horizontal side wall sprinkler
Concealed sprinkler
Providing & fixing of pressure switch in M.S. pipe line including connection etc. as required.
Providing & fixing flow switch in following sizes M.S. pipe including connection etc as required.
100mm dia
150mm dia
Providing, fixing, testing & commissioning of installation control valve of cast iron body, brass/bronze working parts comprising of water motor alarm, bronze seat clapper, clapper arm and hydraulically driven mechanical gong bell to sound continuous alarm when the wet riser/sprinkler system activates, pressure gauges, emergency releases, strainer, pressure switch, cock valve complete with drain valve and bypass, test control box, ball valves, MS pipe of required size, flanges, orifice plate, gasket etc of follwing sizes as required :. 150mm dia
Supplying, installation, testing & commissioning of sprinkler flexible pipe (UL Listed) of stainless steel complete with 15 NPT on reducer thread with maximum working pressure of 175 PSI test pressure of 875 PSI (Burst) with branch line (Inlet) 25mm NPT male thread to sprinkler head (Outlet) 15mm NPT female thread with reducer, nipple, 2 side brackets, center bracket, stockbar of following sizes complete as required.
Supplying, installation, testing & commissioning of deluge valve (to be used for water curtains) UL listed with wet pilot basic trim assembly for DVA with test and alarm, drip and drain valve with water motor gong complete as required.. 100 mm dia
Providing, installation, testing & commissioning of water curtain nozzle 15mm dia nickel chrome plated brass, BSPT, K-factor as per design consideration complete as required.
Providing, installation, testing & commissioning of electric release trim assembly for deluge wall with two way solelnoid valve, weather proof operation on 24 volts DC supply complete as required.
Providing, installation, testing & commissioning of adjustable rosette plate for 15mm dia in white finish UL Listed or FM approved complete as required.
Supplying and fixing of following sizes of steel conduit along with accessories in surface/recess including painting in case of surface conduit, or cutting the wall and making good the same in case of recessed conduit as required.. 25 mm
Supplying and installing following size of perforated pre-painted M.S. cable trays with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required.. 150 mm width x 50mm depth x 1.6 mm thickness.
Providing and fixing in position the industrial type pressure gauges with gun metal / brass valves complete as required
Providing and fixing of Weather proof hose cabinets fabricated from 14 g M.S. Sheet with full glass door and mortise locking arrangement , suitable to accommodate one Hydrant landing valve, 2 nos. 15 M long hose and 1 No branch pipe. The cabinet shall be painted with one coat of primer and finished stove enamelled "Fire Red", "Fire Hose" written on front including suitably mounted on a raised masonry platform as required. (Approx 0.75mx0.6 m x 0.25 m).
Providing and fixing MS partly glazed single/double hung lockable shutter fabricated from MS section as required with 5 mm thick glass for fire station complete including stove enamelled painting of door and frame and words "Fire Hydrant" written on glass, suitable to accommodate 2 Hydrant landing valves, 1 fire hose reel, 2 nos.15m long 63 mm dia hose,1-branch pipe, 1no. fire man's axe, fire extiguishers 2 nos, including suitably mounted on a raised masonry platform as required. (Approx.size 0.90 m x 2.1m )
Providing and fixing resilient rubber neoprene lined single arch vibration eliminators with unit control suitable for raw water upto 450C temperature working pressure 25 kg and test pressure 37.5 kg/cm2.
Supply, Installation, Testing & Commissioning of double flanged vertical air vessel fabricated shell from 10 mm thick & dished ends 12 mm thick M.S.plate, suitable for working pressure of 18 kg/cm2 and test pressure of 27 kg/cm2, 450 mm dia and 2.00 m high for fire pumps complete with four nos dual setting pressure switches to operate jockey and main pumps at drop of pressure as given in the specifications.
Providing & fixing 150 mm diameter MS Class ‘C’ for diesel engine exhaust pipe (including all fittings, clamps, steel support) of suitable dia for the diesel engine. The pipe shall be provided insulation with fibre glass wool and wraped with 24g. aluminium sheet complete with all respect.
Providing and fixing of gun metal fire Brigade Suction Hose coupling (Draw-out Connection) with nut for female coupling as per IS:902- 1974 complete with 100 mm dia. G.I. Suction pipe and 100 mm dia. 1No. C.I. Foot valve flanged (to be connected to static water tank).
Providing and fixing carbon-di-oxide type fire extinguishers consisting of pressure tested single cast cylinder with rotary discharge valve and high pressure discharge tube of minimum 1 m length, discharge horn, suspension bracket conforming to IS:15683 finished externally with red enamel paint and fixed to wall with brackets complete with internal charge (Halon Free Gas). Capacity 4.5 Kg.
Providing and fixing carbon-di-oxide fire extingushers trolley mounted with all accessories internal discharge tube,high pressure discharge hose,discharge nozzle, ISI marked as per IS:2878 finished externally with red enamel paint. (Halon Free Gas). Capacity 22.5 kg.
Providing and fixing ABC Powder type fire extinguishers consisting of welded M.S. cylinderical body, squeeze lever discharge valve fitted with pressure indicating guage internal discharge tube 30 cms long high pressure discharge hose, discharge nozzle, suspension bracket conforming to IS:15683 finished externally with red enamel paint and fixed to wall with brackets complete with internal charge. (Halon Free Gas). Capacity 6.0 Kg.
Providing and fixing 25 mm dia inspecting & testing assembly with drain valve built in bye pass arrangement and connection to drain line. (Giocomini)
HVAC WORK
Supply and installation of 300 mm, 230 v A.C. exhaust fan in the existing opening including making good the damage, connection testing, commissioning etc as required.
Extra for fixing the louvers/ shutters complete with Frame for a exhaust fan of all sizes
Supply and installation of Split Type Air Conditioner-Hi Wall
1.0 TR 5 Star Split AC (Inverter Type) IS 1391 Part -1
1.5 TR 5 Star Split AC (Inverter Type) IS 1391 Part -1
2.0 TR 5 Star Split AC (Inverter Type) IS 1391 Part -1
Copper tube of size 1/4" for split AC unit 1/1.5/2/3 TR capacity including nitrile rubber insulation
Copper tube of size 1/2" for split AC unit 1/1.5/2/3 TR capacity including nitrile rubber insulation
Copper tube of size 3/8" for split AC unit 1/1.5/2/3 TR capacity including nitrile rubber insulation
Copper tube of size 5/8" for split AC unit 1/1.5/2/3 TR capacity including nitrile rubber insulation
4 kVA wall mounted automatic voltage stabilizer from ranges 140V to 280V
5 kVA wall mounted automatic voltage stabilizer from ranges 140V to 280V
Drain Pipe for AC
Outdoor stand for 1.5 TR Split AC
Outdoor stand for 2.0 TR Split AC
FR PVC insulated 3 core 4 sqmm copper wire
Inline Fan: - Supply, Loading, Unloading, Lifting, Shifting, installation, testing, commissioning of low noise acoustically lined inline fan with vibration isolators, fire rated double canvas connection & speed regulator, complete as per specification and drawing.
380 CFM @ 25 mm SP
650 CFM @ 25 mm SP
600 CFM @ 25 mm SP
500 CFM @ 25 mm SP
550 CFM @ 25 mm SP
425 CFM @ 25 mm SP
475 CFM @ 25 mm SP
560 CFM @ 25 mm SP
500 CFM @ 25 mm SP
450 CFM @ 25 mm SP
460 CFM @ 25 mm SP
380 CFM @ 25 mm SP
675 CFM @ 25 mm SP
Supply, installation, balancing and commissioning of factory fabricated GSS sheet metal rectangular/round ducting complete with neoprene rubber gaskets, elbows, splitter dampers, vanes, hangers, supports etc. as per approved drawings and specifications of following sheet thickness complete as required.
Thickness 0.63 mm sheet
Thickness 0.80 mm sheet
Thickness 1.00 mm sheet
Thickness 1.25 mm sheet
Supply, installation, balancing and commissioning of fabricated at site GSS sheet metal rectangular/round ducting complete with neoprene rubber gaskets, elbows, splitter dampers, vanes, hangers, supports etc. as per approved drawings and specifications of following sheet thickness complete as required.
Thickness 0.63 mm sheet
Thickness 0.80 mm sheet
Thickness 1.00 mm sheet
Thickness 1.25 mm sheet
Air Scrubber (Wet Type): - Supply, Installation, Testing and Commissioning of double skin type floor mounted kitchen scrubber of extruded Alumunium section with 0.8 mm preplaticised / precoated GI Sheet outside and 0.8 mm plain galvanized sheet inside, complete with 43 mm thick insulated panels pressure injected with PUF insulation of 40 kg/m3 density, backward curved blower/ Plug Fans, having pre filter section for removal of oil grease, followed by intaks louvers, impingement plate section, high pressure water atomisation section, mist eliminator and oulet cone section, fan section, expansion chamber, nozzles, strainers, beltdrives with guard, gasket tight access door, eliminators, water circulation pumps, isolation valves for pumps, vibration isolators for blower distribution panels etc complete as per specifications and drawings. 1200 CFM at 75 MM SP , Appx 0.75 KW.
Air Washer: - Supply, Installation, Testing and Commissioning of Double Skin Packaged Type Air Washer with 0.63 mm preplasticized/precoated GI sheet outside and 0.63 mm plain Galvanized sheet inside with 25mm injected PUF insulation of 48KG/m3 , G.I. blower section, DIDW Blower (Backward Curved/ Plug Fans) with motors , base , drive arrangement ,Filter, cooling pad section, SS-304- Sump Tank and housing, motor drive, water circulation pump, piping, valves & fittings etc. suitable for Outdoor Application as per specifications and drawings .
1000 CFM at 50 MM SP , Appx 0.75 KW
15000 CFM at 50 MM SP , Appx 7.5 KW
5400 CFM at 50 MM SP , Appx 3.75 KW
BOUNDARY WALL
Earth Work in excavation in Foundation Trenches in Ordinary soil (vide classification of soil item -B) and disposal of excavated earth as obtained to a distance upto 50 M including all lift, leveling ramming the foundation trenches, removing roots of tree shrubs all complete as per approved design, building specification and direction of E/I
Earth filling in foundation trenches and plinth in layer not exceeding 150mm thick will watered rammed fully compacted and fine dressed with earth obtained from excavation of foundation trenched with a lead of 50mm and lift of 1.5M all complete as per building specification and direction of E/I. (Mode of measurement compacted volume).
Removal & disposal of surplus excavated earth by mechanical transport including loading unloading stacking and spreading at all lift and lead up to 13km to spoil dump approved by local authority.
Providing P.C.C. (1:3:6) in foundation (Plain cement concrete 1:3:6 nominal mix in foundation with crushed stone aggregate 40 mm nominal size mechanically mixed , placed in foundation and compacted by vibrating curing, for 14 days.)nas per building specification and direction of Engineer-in-charge.
Providing and laying in position ready mixed M-25 grade concrete for reinforced cement concrete work, using fly ash and cement content as per approved design mix, including pumping of R.M.C. from transit mixer to site of laying, excluding the cost of centering, shuttering, finishing and reinforcement, including cost of admixtures in recommended proportions as per IS : 9103 to accelerate / retard setting of concrete, improve workability without impairing strength and durability as per direction of the Engineer - in - charge. NOTE- (1) Cement content considered in this item is @ 330 kg/cum. Excess/ less cement used as per design mix is payable/ recoverable separately.
All works upto plinth level
All works above plinth level upto floor V level
Add for using extra cement in the items of design mix over and above the specified cement content therein.
Centering and shuttering including strutting, propping etc. and removal of form for : Foundations, footings, bases of columns, etc. for mass concrete
Centering and shuttering including strutting, propping etc. and removal of form for Lintels, beams, plinth beams, girders, bressumers and cantilevers
Centering and shuttering including strutting, propping etc. and removal of form for :Columns, Pillars, Piers, Abutments, Posts and Struts
Providing Tor steel reinforcement of 8mm. dia. rods as per approved design and drawing excluding carriage of M.S. bars to work site , cutting, bending and binding with annealed wire with cost of wire, removal of rust placing the rods in position all complete as per building specification and direction of E/l. (TMT Fe 500 (only vailid for TATA (TISCON), SAIL, JSPL, Electro steel Limited Bokaro and Vizal steel(RINL))
Providing Tor steel reinforcement of 10mm. dia. rods as per approved design and drawing excluding carriage of M.S. bars to work site , cutting, bending and binding with annealed wire with cost of wire, removal of rust placing the rods in position all complete as per building specification and direction of E/l. (TMT Fe 500 (only vailid for TATA (TISCON), SAIL, JSPL, Electro steel Limited Bokaro and Vizal steel(RINL))
Providing Tor steel reinforcement of 12mm. to 32mm. dia. rods as per approved design and drawing excluding carriage of M.S. bars to work site , cutting, bending and binding with annealed wire with cost of wire, removal of rust placing the rods in position all complete as per building specification and direction of E/l. (TMT Fe 500 (only vailid for TATA (TISCON), SAIL, JSPL, Electro steel Limited Bokaro and Vizal steel(RINL))
Providing designation 100A brick work with flyash lime brick (FLAG) confirming to IS 12894-1990 (9"x425"x3") in C.M. (1:4) in foundation and plinth with approved quality of clean coarse sand of F.M. 2 to 2.5 including providing 10mm thick mortar joints costs of screening materials, raking out joints to 15mm depth curing taxes and royalty all complete as per building specification and direction of E/I.
Providing designation 100A brick work with flyash lime brick (FLAG) confirming to IS 12894-1990 (9"x4.5"x3") in C.M. (1:4) in super structure with approved quality of clean coarse sand of F.M. 2 to 2.5 including providing 10mm thick mortar joints costs of screening materials, scaffolding, raking out joints to 15mm depth curing taxes and royalty all complete as per building specification and direction of E/I.
Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.).
Stone tile (polished) work for wall lining over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and cement slurry @ 3.3 kg/SQM including pointing in white cement complete. Granite of any colour and shade
18 mm cement plaster in two coats under layer 12 mm thick cement plaster 1:5 (1 cement: 5 coarse sand) and a top layer 6 mm thick cement plaster 1:3 (1 cement : 3 coarse sand) finished rough with sponge.
Finishing walls with water proofing cement paint of required shade : New work (Two or more coats applied @ 3.84 kg/10 SQM) SQM 57.85
Finishing walls with textured exterior paint of required shade : New work (Two or more coats applied @ 3.28 ltr/10 SQM) over and including priming coat of exterior primer applied @ 2.20kg/10 SQM
CARRAIGE OF MATERIALS
CEMENT ( 5KM )
SAND ( 40KM )
CHIPS ( 22KM )
METAL ( 22KM )
STEEL ( 5KM )
BRICKS ( 40KM )
SITE DEVELOPMENT
Earth Work in excavation in Foundation Trenches in Ordinary soil (vide classification of soil item -B) and disposal of excavated earth as obtained to a distance upto 50 M including all lift, leveling ramming the foundation trenches, removing roots of tree shrubs all complete as per approved design, building specification and direction of E/I
Earth filling in foundation trenches and plinth in layer not exceeding 150mm thick will watered rammed fully compacted and fine dressed with earth obtained from excavation of foundation trenched with a lead of 50mm and lift of 1.5M all complete as per building specification and direction of E/I. (Mode of measurement compacted volume).
Removal & disposal of surplus excavated earth by mechanical transport including loading unloading stacking and spreading at all lift and lead up to 13km to spoil dump approved by local authority.
Providing P.C.C. (1:3:6) in foundation (Plain cement concrete 1:3:6 nominal mix in foundation with crushed stone aggregate 40 mm nominal size mechanically mixed , placed in foundation and compacted by vibrating curing, for 14 days.)nas per building specification and direction of Engineer-in-charge.
water bond macadam: - Providing, laying spreading & compacting stone aggregates of specific size to water bond macadam specification including spreading in uniform thickness hand packing, rolling with vibratory roller 8-10 tone / smothery wheeled steel roller in stages to proper gate & chamber, applying and booming requisite type of screening / binding materials to fill up the interstices of course aggregate, water and compacting to the required density. (B) By mechanical means, (b) Using screening Type - A (13.2mm Agg.) with vibratory roller
Cast in Situ Cement Concrete M20 kerb (Construction of cement concrete kerb with top and bottom width 115 and 165 mm respectively, 250 mm high in M 20 grade PCC on M-10 grade foundation 150 mm thick, foundation having 50 mm projection beyond kerb stone, kerb stone laid with kerb laying machine, foundation concrete laid manually, all complete as per clause 408
Providing and laying in position ready mixed M-25 grade concrete for reinforced cement concrete work, using fly ash and cement content as per approved design mix, including pumping of R.M.C. from transit mixer to site of laying, excluding the cost of centering, shuttering, finishing and reinforcement, including cost of admixtures in recommended proportions as per IS : 9103 to accelerate / retard setting of concrete, improve workability without impairing strength and durability as per direction of the Engineer - in - charge. NOTE- (1) Cement content considered in this item is @ 330 kg/cum. Excess/ less cement used as per design mix is payable/ recoverable separately.
All works upto plinth level
All works above plinth level upto floor V level
Centering and shuttering including strutting, propping etc. and removal of form for : Foundations, footings, bases of columns, etc. for mass concrete
Centering and shuttering including strutting, propping etc. and removal of form for : Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc.
Centering and shuttering including strutting, propping etc. and removal of form for : Suspended floors, roofs, landings, balconies and access platform
Centering and shuttering including strutting, propping etc. and removal of form for Lintels, beams, plinth beams, girders, bressumers and cantilevers
Centering and shuttering including strutting, propping etc. and removal of form for :Columns, Pillars, Piers, Abutments, Posts and Struts
Providing Tor steel reinforcement of 8mm. dia. rods as per approved design and drawing excluding carriage of M.S. bars to work site , cutting, bending and binding with annealed wire with cost of wire, removal of rust placing the rods in position all complete as per building specification and direction of E/l. (TMT Fe 500 (only vailid for TATA (TISCON), SAIL, JSPL, Electro steel Limited Bokaro and Vizal steel(RINL))
Providing Tor steel reinforcement of 10mm. dia. rods as per approved design and drawing excluding carriage of M.S. bars to work site , cutting, bending and binding with annealed wire with cost of wire, removal of rust placing the rods in position all complete as per building specification and direction of E/l. (TMT Fe 500 (only vailid for TATA (TISCON), SAIL, JSPL, Electro steel Limited Bokaro and Vizal steel(RINL))
Providing Tor steel reinforcement of 12mm. to 32mm. dia. rods as per approved design and drawing excluding carriage of M.S. bars to work site , cutting, bending and binding with annealed wire with cost of wire, removal of rust placing the rods in position all complete as per building specification and direction of E/l. (TMT Fe 500 (only vailid for TATA (TISCON), SAIL, JSPL, Electro steel Limited Bokaro and Vizal steel(RINL))
Providing designation 100A brick work with flyash lime brick (FLAG) confirming to IS 12894-1990 (9"x425"x3") in C.M. (1:4) in foundation and plinth with approved quality of clean coarse sand of F.M. 2 to 2.5 including providing 10mm thick mortar joints costs of screening materials, raking out joints to 15mm depth curing taxes and royalty all complete as per building specification and direction of E/I.
Kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) :25 mm thick
Kota stone slabs 20 mm thick in risers of steps, skirting, dado and pillars laid on 12 mm (average) thick cement mortar 1:3 (1 cement: 3 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing and polishing complete.
Providing and laying factory made chamfered edge Cement Concrete paver blocks in footpath, parks, lawns, drive ways or light traffic parking etc, of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over 50mm thick compacted bed of sand, compacting and proper embedding/laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand. complete all as per direction of Engineer-in-Charge.60mm thick cement concrete paver block of M-35 grade with approved colour, design & pattern.
Painting runway/taxi track/apron marking with adequate nos of coats to give uniform finish with road marking paint of superior make as approved by the Engineer-in-charge, i/c cleaning the surface of ail dirt, scales, oil. New work (Two or more coats)
Providing and applying plaster of paris putty of 2 mm thickness over plastered surface to prepare the surface even and smooth complete.
18 mm cement plaster in two coats under layer 12 mm thick cement plaster 1:5 (1 cement: 5 coarse sand) and a top layer 6 mm thick cement plaster 1:3 (1 cement : 3 coarse sand) finished rough with sponge.
Providing 6mm thick cement plaster (1:4) in ceiling with clean coarse sand of F.M. 1.5 including screening, curing with all leads and lifts of water, scaffolding taxes and royalty all complete as per specification and direction of E/I.
Finishing walls with water proofing cement paint of required shade :. New work (Two or more coats applied @ 3.84 kg/10 SQM) SQM 57.85
Finishing walls with textured exterior paint of required shade : New work (Two or more coats applied @ 3.28 ltr/10 SQM) over and including priming coat of exterior primer applied @ 2.20kg/10 SQM
CARRAIGE OF MATERIALS
CEMENT ( 5KM )
SAND ( 40KM )
CHIPS ( 22KM )
METAL ( 22KM )
STEEL ( 5KM )
BRICKS ( 40KM )
Ground preparation, grassing and plantation
Supplying and stacking of good earth at site including royalty and carriage up to 1 km (earth measured in stacks will be reduced by 20% for payment).
Supplying and stacking at site dump manure from approved source, including carriage up to 1.0 km (manure measured in stacks will be reduced by 8% for payment)
Screened through sieve of IS designation 20 mm
Screened through sieve of IS designation 16 mm
Screened through sieve of IS designation 4.75 mm
Supplying and stacking of well decayed cow dung manure at site including royalty and carriage up to 1.0 km (cow dung manure measured in stacks will reduced by 8% for Payment)
PREPARATION WORKS: - Trenching in ordinary soil up to a depth of 60 cm including removal and stacking of serviceable materials and then disposing of surplus soil, by spreading and neatly levelling within a lead of 50 m and making up the trenched area to proper levels by filling with earth or earth mixed with sludge or / and manure before and after flooding trench with water (excluding cost of imported earth, sludge or manure)
Rough dressing the trenched ground including breaking clods
Uprooting weeds from the trenched area after 10 to 15 days of its flooding with water including disposal of uprooted vegetation
Fine dressing of the ground
Spreading of sludge, dump manure and / or good earth in required thickness as per direction of Engineer-in-charge (cost of sludge, dump manure and / or good earth to be paid separately).
Mixing earth and sludge or manure in the required proportion specified or directed by the Engineer-in-charge
Uprooting rank vegetation and weeds by digging the area to a depth of 60 cm, removing all weeds and other growth with roots by forking repeatedly, breaking clods, rough dressing, flooding with water, uprooting fresh growths after 10 to 15 days and then fine dressing for planting new grass, including disposal of all rubbish with all leads and lifts
Digging holes in ordinary soil and refilling the same with the excavated earth mixed with manure or sludge in the ratio of 2:1 by volume (2 parts of stacked volume of earth after reduction by 20% : 1 part of stacked volume of manure after reduction by 8%) flooding with water, dressing including removal of rubbish and surplus earth, if any, with all leads and lifts (cost of manure, sludge or extra good earth if needed to be paid for separately)
Holes 1.2 m diameter and 1.2 m deep
Holes 90 cm diameter and 90 cm deep
Holes 60 cm diameter and 60 cm deep
Providing and stacking of Albizzia lebbek of height 150-165 cm. in bag of size 25 cm as per direction of the officer-in-charge.
Providing and stacking of Azadirachta indica ( Neem ) of height 120-130cm in big polybag of size 25 cm as per direction of the officer-in-charge.
Providing and stacking of Bauhinia purpurea (Kachnar) of height 150-165 cm. in big poly bags of size 25 cm as per direction of the officer-in-charge.
Providing and stacking of Cassia fistula (Amaltash) of height 120-135 cm. in big poly bags of size 25 cm as per direction of the officer-in-charge.
Providing and stacking of Cassia javanica of height 120-150 cm. in big poly bags of size 25 cm as per direction of the officer-in-charge.
Providing and stacking of Mangifera indica (Mango-grafted ) of height 60-75 cm. in big poly bag of size 25 cm as per direction of the officer-in-charge.
Providing and stacking of Mimusops elengi (Maulsri) of height 180-195 cm., well developed with thick stem in big in big size HDPE bag as per direction of the officer-in-charge.
Providing and stacking of Peltophorum species of height 150-165 cm. in big poly bags of size 25 cm as per direction of the officer-in-charge.
Providing and stacking of Plumeria rubra of height 120-150 cm. with 3-4 branches and thick stem in big size HDPE bags as per direction of the officer-in-charge.
Providing and stacking of Pongamia glabra (Papri) of height 120-135 cm. in big poly bag of size 25 cm as per direction of the officer-in-charge.
Providing and stacking of Saraca indica (Sita Ashok) of height 105-120 cm. in big poly bags of size 25 cm as per direction of the officer-in-charge.
Providing and stacking of Spathodea campanulata of height 150-165 cm. in big poly bags of size 25 cm as per direction of the officer-in-charge.
Providing and stacking of Tabebuia sp. of height 150-165 cm. in big polybags of size 25 cm as per direction of the officer-in-charge.
Providing and displaying of Brassia Variegated having ht. 30 cm, well developed with fresh and healthy foliage in 20 cm size of Earthen pot/ Plastic pot & as per direction of the officer-in-charge.
Providing and Displaying Acalypha Different colour well developed, fresh & healthy with good foliage, multi branch 30 to 45 cm ht. in 20 cm size of Earthen Pot/ Plastic Pot bushy as per direction of the officer-in-charge.
Providing and stacking of Clerodendrum inerme having ht. 25 cm to 30 cm multi branched in 20 cm size of Earthen Pot/Plastic Pot & as per direction of the officer-in-charge.
Providing and stacking of Caesalpinia pulcherrima species of height 45-60 cm. in earthen pot of size 20 cm as per direction of the officer-in-charge.
Providing and stacking of Euphorbia pulcherrima (dark red) well branched (poinsettia Red Hegg) of height 60-75 cm. in earthen pots of size 25 cm as per direction of the officer-in-charge.
Providing and stacking of Ficus reginald well branched, bushy of height 60- 75 cm. in earthen pots of size 25 cm as per direction of the officer-in-charge.
Providing and stacking of Ficus panda of height 90-105 cm. with 10-12 branches and healthy foliage, well formed in cement pots of size 30 cm as per direction of the officer-in-charge.
Providing and stacking of Hamelia patens of height 30-45 cm. with 3-4 branches in poly bags of size 20 cm as per direction of the officer-in-charge.
Providing and stacking of Largerstroemia indica of height 45-60 cm. in polybag of size 20 cm as per direction of the officer-in-charge.
Providing and stacking of Putranjiva roxburghii of ht. 45-60 cm in bag of size 15 cm as per direction of the officer-in-charge.
Providing and Displaying Bamboo Buddha vally variety with umbrella shape having 120 to 135 ht. with fresh & healthy foliage well developed in 40 cm Cement pot multy branch, bushy as per direction of the officer-in-charge.
Providing and stacking of Alpinia Variegated (three in one) having ht. 30 cm and above, with fresh and healthy variegated foliage in 25 cm size of Earthen Pot/Plastic Pot & as per direction of the officer-in-charge.
Providing and stacking of Alternanthera species of height 15 cm to 20 cm, full of branches and foliage in 15 cm size of Earthen Pot/Plastic Pot & as per direction of the officer-in-charge.
Providing and stacking of Chlorophytum (Green), full of leafy suckers in 15 cm size of Earthen Pot/Plastic Pot & as per direction of the officer-in-charge.
Providing and stacking of Cuphea chinensis of ht. 20-30 cm full of branches and healthy foliage in 15 cm size of Earthen Pot/Plastic Pot & as per direction of the officer-in-charge.
Providing and stacking of Duranta Golden, having ht.15 to 20 cm bushty shape with fresh and healthy leaves in 15 cm size of Earthen Pot/Plastic Pot & as per direction of the officer-in-charge.
NOTE: All The rates quoted between Sl. No. 1 to 844 above shall be deemed to include All the applicable Taxes and Labour Cess
M/S SADANAND GUPTA
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 0.20 MB
SBDHazaribagMB.pdf
Tender Documents • 1.17 MB
Drawings.pdf
Additional Documents • 5.41 MB
TechSpecification.pdf
Additional Documents • 4.25 MB
BOQ_70206.xls
BOQ • 0.84 MB
Download all tender documents and submit your bid