Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹36.4 LAccepted-AOC VILL AMRAH P O SAKTIGARH DIST PURBA BARDHAMAN PIN 713149 | SAKTIGARH | PURBA BARDHAMAN | WEST BENGAL | 713149 | ₹36.4 L | L1 | Accepted-AOC L1 |
| 2 | L2₹36.9 LRejected-AOC VILL P O BAHIRI PASCHIMPARA P S BOLPUR DIST BIRBHUM PIN 731240 | BOLPUR | BIRBHUM | WEST BENGAL | 731240 | ₹36.9 L | L2 | Rejected-AOC L2 |
| 3 | L3₹37.2 LRejected-Finance VILL PO BAHIRI PS BOLPUR DIST BIRBHUM PIN 713240 | BAHIRI | BIRBHUM | WEST BENGAL | 713240 | ₹37.2 L | L3 | Rejected-Finance L3 |
| 4 | Rejected-Technical VILL NOWDAPARA P O GOALJAN P S BERHAMPORE DIST MURSHIDABAD | MURSHIDABAD | WEST BENGAL | 742187 | - | - | Rejected-Technical Dis - Qualified for this NIT due to P. Tax Certificate not sumbitted and Credential not in order. |
Tender Value
₹36.4 L
EMD Value
₹72,769
Closing Date
27 Mar 2026, 3:30 pmClosed
Executive Engineer
Office of the Executive Engineer-Burdwan Division-Social Sector-P.W.Dte.- Jagatberh-Surya Nagar-Sripally-Burdwan-Pin-713103
Construction of Civil works (Boundary wall, Dining Kitchen Shed) at Integrated English Medium School, Monteswar Block in Purba Bardhaman under DMF under Katwa Sub-Division , P.W.D under Burdwan Division , P.W.D Social Sector
2026_WBPWD_1020221_1
WBPWD/SS/EE/BDN/ NIT_23/ 2025_2026
Open Tender
CIVIL WORKS
60 days
Monteswar
Please refer Tender documents.
4 documents required · 4 mandatory
₹72,769
Yes
O/O EE, Burdwan Division ,Social Sector , PWDte
4 Jun 2026
10 Mar 2026
30 Mar 2026
11 Mar 2026
27 Mar 2026
16 Mar 2026
16 Mar 2026
Part-A Boundary wall :- Earth work in excavation of foundation trenches or drains, in all sorts of soil (including mixed soil but xcluding laterite or sandstone) including removing, spreading or stacking the spoils within a lead of 75 m. as directed. The item includes necessary rimming the sides of trenches, levelling, dressing and ramming the bottom, bailing out water as required complete.For boundary wall ( 180.00 mtr length)
(A) Filling in foundation or plinth by silver sand in layers not exceeding 1 50 mm as directed and consolidating the same by thorough saturation with water ramming complete including the cost of supply of sand, (payment to be made on measurement of finished quantity) by fine sand.
Single Brick Flat Soling of picked jhama bricks including ramming and dressing bed to proper level and filling joints with local sand.
I) Cement concrete with graded stone ballast (40 mm size excluding shuttering) In ground floor (A) [Pakur Variety] (a) 1:3:6 proportion
ordinary cement concrete (1:1.5:3) pakur variety
Reinforcement for reinforced concrete work in all sorts of structures including distribution bars, stirrups, binders etc initial straightening and removal of loose rust (if necessary), cutting to requisite length, hooking and bending to correct shape, placing in proper position and binding with 16 gauge black annealed wire at every intersection, complete as per drawing and direction. (JSW/JSPL/SHYAM/SRMB/BMASL) Source at Durgapur.
Hire and labour charges for shuttering with centreing and necessary staging upto 4.0m. Using approved stodt props and thickness with required bracing for concrete slabs, beams,m column, lintels, curved or straight including fitting, fixing and stricking out after completion of works. (Upto roof of ground floor) (c) Steel shuttering or 9 to 12 mm thick approved quality ply board shuttering in any concrete work Ground Floor
25 mm.to 30 mm thick wooden shuttering without staging in foundation etc. ground floor.
125 mm. thick brick work with 1st class bricks in cement mortar (1:4) in ground floor.
Providing, Plaster (to wall, floor, ceiling etc.) with sand and cement morter including rounding off or chamfering corners as directed and raking out joints or rounding of concrete surface, including throating, nosing and drip course where necessary.With 6:1 cement morter.15mm. Thick plaster
Applying Exterior grade Acrylic primer of approved quality and brand on plastered or cencrete surface old or new surface to receive decorative textured(matt finish) or smooth finish acrylic exterior emulsion paint including scraping and preparing the surface throughly, complete as per manufacturer's specification and as per direction of the EIC. (a) two Coat In Ground Floor:
Protective and Decorative Acrylic exterior emulsion paint of approved quality, as per manufacturer's specification and as per direction of EIC to be applied over acrylic primer as required. The rate includes cost of material, labour, scaffolding and all incidental charges but excluding the cost of primer. (iii) Two coats. In Ground floor
M.S. gate of Jail type as per approved design made of strong M.S. frame work, intermediate stiffeners and round / square bars or angles. M.S. sheet (not less than 14 gauge) gussets, cleats etc. Including necessary riveting, bolting, welding, locking and hanging arrangements, fitting and fixing complete as per direction of the Engineer-in -charge.In ground floor. For Main Entrance
(b)Providing Priming one coat on steel or other metal surface with synthetic oil bound primer of approved quality including smoothening surfaces by sand papering etc.On steel surface
Providing painting with best quality syathetic enamel paint of approved make and brand including smoothening surface by sand papering etc. including using of approved putty etc. on the surface, if necessary. (b) On steel or other metal surface With Super gloss ( hi- gloss) Two coats ( Except White)
Direction and Place Identification Signs upto 0.9 sqmSize Board. Providing and erecting direction and place identification retro-reflectorised sign as per IRC:67 made of high intensity grade sheeting vide clause 801.3, fixed over aluminium sheeting, 2 mm thick with area not exceeding 0.9 sqm supported on a mild steel single angle iron post 75 x 75 x 6 mm firmly fixed to the ground by means of properly designed foundation with M15 grade cement concrete 45 x 45 x 60 cm, 60 cm below ground level as per approved drawing and Clause 801 of Specifications for Road &Bridge Works of MoRT&H (5th Revision
Part B-- Kitchen cum Dining shed:- Earth work in excavation of foundation trenches or drains, in all sorts of soil (including mixed soil but xcluding laterite or sandstone) including removing, spreading or stacking the spoils within a lead of 75 m. as directed. The item includes necessary rimming the sides of trenches, levelling, dressing and ramming the bottom, bailing out water as required complete.
(A) Filling in foundation or plinth by silver sand in layers not exceeding 1 50 mm as directed and consolidating the same by thorough saturation with water ramming complete including the cost of supply of sand, (payment to be made on measurement of finished quantity) by fine sand.
Single Brick Flat Soling of picked jhama bricks including ramming and dressing bed to proper level and filling joints with local sand.
I) Cement concrete with graded stone ballast (40 mm size excluding shuttering) In ground floor (A) [Pakur Variety] (a) 1:3:6 proportion
Controlled Cement concrete with well graded stone chips (20 mm nominal size) excluding shuttering and reinforcement with complete design of concrete as per IS : 456 and relevant special publications, submission of job mix formula after preliminary mix design after testing of concrete cubes as per direction of Engineer-in charge. Consumption of cement will not be less than 300 Kg of cement with Super plasticiser per cubic meter of controlled concrete but actual consumption will be determined on the basis of preliminary test and job mixfoumula. In ground floor and foundation.[using concrete mixture] (b) M 25 Grade
Reinforcement for reinforced concrete work in all sorts of structures including distribution bars, stirrups, binders etc initial straightening and removal of loose rust (if necessary), cutting to requisite length, hooking and bending to correct shape, placing in proper position and binding with 16 gauge black annealed wire at every intersection, complete as per drawing and direction.(JSW/JSPL/SHYAM/SRMB/BMASL) Source at Durgapur.
Hire and labour charges for shuttering with centreing and necessary staging upto 4.0m. Using approved stodt props and thickness with required bracing for concrete slabs, beams,m column, lintels, curved or straight including fitting, fixing and stricking out after completion of works. (Upto roof of ground floor) (c) Steel shuttering or 9 to 12 mm thick approved quality ply board shuttering in any concrete work Ground Floor . .
25 mm.to 30 mm thick wooden shutter without staging in foundation etc.
Brick work with 1st class bricks in cement mortar (1:6) (a) In foundation and plinth.(b) In superstructure ground floor.
(b) In superstructure
125 mm. thick brick work with 1st class bricks in cement mortar (1:4) in ground floor.
18 mm. to 22 mm. thick, kota stone slab set in 20 mm thick (avg) cement mortar (1:4) in floor, stair & lobby including pointing in cement slurry with admixture of pigment matching the stone shade, including grinding & polishing as per direction of Engineer - in - charge to match with the existing work. [Slurry for bedding @ 4.4 kg/Sq.m and pointing @2.0 kg/Sq.m] Ground floor less tiles at top portion of dining and seat
Supplying, fitting & fixing true to line and level digitalelevation Ceramic tiles of approved brand conforming to IS:15622:2006 Group B III and tested as per IS:13630:2006 as ornamental cladding on external wall in natural stone, brick, wood, bamboo pattern/ design fixed with adhesive 4.5 mm thick at the back of each tile & finishing the joints with white cement mixed with colouring oxide if required to match the colour of tiles including roughening of concrete surface, if necessary or by synthetic adhesive & grout materials etc. With polymerised adhesive and epoxy grout pointing including spacer - 2mm (When tiles are laid over existing hard ready surface) all complete as per direction of Engineer-in-charge.
Supplying and laying chequered tiles of any shade & of approved quality with (1:1½:3) cement concrete laid in panels or patterns as directed in pavement, footpath etc. including necessary underlay 25 mm thick [avg] cement mortar (1:3) complete in all respect with all labour and materials. [Using cement slurry @ 4.4 kg/Sq.m at back side and @2.4 kg/Sq.m for joint filling] Red Variety.(i) 25 mm. thick.
(a) M.S.or W.I. Ornamental grill of approved design joints continuously welded with M.S, W.I. Flats and bars of windows, railing etc. fitted and fixed with necessary screws and lugs in ground floor. (ii) Grill weighing above 10 KG TO 16 Kg./sq.mtr Ground Floor
Supplying,fitting & fixing of 2-Track / 3-Track Aluminium sliding Window of all Aluminium sections viz. window frame (top,bottom & side frame), shutter (top, bottom, side & interlock member) made of aluminium alloy extrusions conforming to IS 733-1983 & IS 1285-1975, annodised conforming to IS 1868-1983, fitted with all other accessories viz. PVC roller, EPDM gasket, maruti lock, screws etc. including labour charges for fitting & fixing of aluminium 2-track/3-track sliding window with fixing of glass (excluding cost of glass) all complete as per architectural drawings and direction of Engineer-in-charge. 10-12 Micron thickness Annodizing film Natural white [Note : for estimate purpose construction wing may consider weight of 2- track Aluminium window @ 5.5 Kg per Sq.M.and 3-track Aluminium window @ 6.5 Kg per Sq.M]
Supplying bubble free float glass of approved make and brand conforming to IS: 2835-1987.ii) 4mm thick coloured / tinted / smoke glass.
Providing, Plaster (to wall, floor, ceiling etc.) with sand and cement morter including rounding off or chamfering corners as directed and raking out joints or rounding of concrete surface, including throating, nosing and drip course where necessary.With 6:1 cement morter.15mm. Thick plaster
20 mm With 6:1 cement morter.Ground floor
Neat cement punning about 1.5 mm. thick in wall, dado, window, sills, floor, drain etc. NOTE : Cement 0.152 cu.m. per 100 sq.m.
Applying Exterior grade Acrylic primer of approved quality and brand on plastered or cencrete surface old or new surface to receive decorative textured(matt finish) or smooth finish acrylic exterior emulsion paint including scraping and preparing the surface throughly, complete as per manufacturer's specification and as per direction of the EIC.(a) two Coat
Protective and Decorative Acrylic exterior emulsion paint of approved quality, as per manufacturer's specification and as per direction of EIC to be applied over acrylic primer as required. The rate includes cost of material, labour, scaffolding and all incidental charges but excluding the cost of primer.(iii) Two coats.In Ground floor b) Premium 100% Acrylic Emulsion
M.S. gate of Jail type as per approved design made of strong M.S. frame work, intermediate stiffeners and round / square bars or angles. M.S. sheet (not less than 14 gauge) gussets, cleats etc. Including necessary riveting, bolting, welding, locking and hanging arrangements, fitting and fixing complete as per direction of the Engineer-in -charge.In ground floor. For Main Entrance
(b)Providing Priming one coat on steel or other metal surface with synthetic oil bound primer of approved quality including smoothening surfaces by sand papering etc.
Providing painting with best quality syathetic enamel paint of approved make and brand including smoothening surface by sand papering etc. including using of approved putty etc. on the surface, if necessary.(b) On steel or other metal surface.With Super gloss ( hi- gloss) Two coats ( Except White)
M.S. structural works with hollow sections (square or rectangular shape) conforming to IS: 806-1968 & IS:1161-1998) connected to one another with bracket, gusset, cleat as per design, drawing & direction of Engineer-in-Charge complete including cutting to requisite shape & size, fabrication including metal arc welding conforming to IS: 816-1969 & IS: 9595 using electrodes of approved make and brand conforming to IS:814- 2004, haulage, hoisting and erection all complete. The rate includes the cost of all M.S. Hollow section, all consumables such as electrodes, gas and hire charges of all tools and plants and labour reqired for execution and all incidental chages (such as electricity, labour insurance) etc. complete Payment to be made on the basis of calculated weight of structural memebrs of MS Holow Section as specified in relevent IS code in finished work. Payment for gusset, bracket, cleat may be made by adding the actual weight of such items with weight of finished structural members. The rates are considered for a hight of erection 8 m. / 2nd floor level from the ground. Add 1.5 % extra over the rate for each additional floor or 4m. beyond the initial 8 m. or part thereof.i) For roof truss works a) Span up to 12 Mtr
Supplying, fitting & fixing Zn-Al alloy (55% Al & 45% Zn) coating of 150 grams per sq. metre (followed by colour coated on both side) steel sheet work having minimum yield strength of 550 Mpa of trapizoidal profile of approved make(excluding the supporting frame work) fitted and fixed with 55 mm & 25 mm self tapping screw, EPDM Washer 16 mm dia & 3 mm th. washer etc. complete with 150 mm end lap and one corrugation minimum side lap. (Payment to be made on area of finished work) a) With 0.5 mm thick sheet
Galvanised iron sheet ridging fitted with necessary bolts,screws, washers etc complete.(225mm end lapping)(B) 450 mm lapping each way(b) With 0.63 mm sheet
Galvanised or painted wind-tie made of M.S. flats, fitted and fixed complete including cost of necessary fittings.
Supplying, fitting & fixing UPVC pipes A- Type and fittings conforming to 15:13592-1992 with all necessary clamps nails. including making holes in walls, floor etc. cutting trenches in any soil through masonry concrete structures etc if necessary and mending good damages including joining with jointing materails (SpunYarn,Valamoid /Bitumen / M-Seal etc) complete. 110 mm. Dia.A) UPVC Pipes:
B) UPVC Fittings:a) Plain Tee
d) Shoe
Supplying, fitting and fixing in position G.I.pipes of TATA make for underground works with all necessary accessories,specials viz.socket, bend, tee, union, cross, elbow, nipple, short piece etc.including cost of all materials,jointing materials ,cutting pipes,making threads,cutting trenches upto 1.5 metre below surface in all sorts of soil and refilling the same as directed with two coats of painting on G.I. pipes and specials with bituminous paint complete in all respect. (Payment will be made on the centre line measurement of the total pipe line including all specials No separate payment will be made for accessories, specials.Payment for painting will be made seperately) (vi) 50 mm dia. medium quality
Supplying, fitting and fixing CPVC (Chlorinated Polyvinyl Chloride) pipes of approved make conforming to IS-15778: 2007 . with all necessary accessories, specials viz. socket, bend, tee, union, cross, elbo, nipple, longscrew, reducing socket, reducing tee, short piece etc. fitted with holder bats clamps, including cutting pipes, fitting, fixing etc. complete in all respect including cost of all necessary fittings as required,jointing materials in any position above ground. (Payment will be made on the centre line measurements of total pipe line including all specials. No separate payment will be made for accesories, specials.(B) For Concealed Work (c) 25 mm dia(i) CPVC Pipes Class-1,SDR-11
Supplying, fitting and fixing white vitreous china best quality approved make wash basin with C.I. brackets on 75 mm X 75 mm wooden blocks, C.P. waste fittings of 32 mm dia., one approved quality brass C.P. pillar cock of 15 mm dia., C.P. chain with rubber plug of 30 mm dia., approved quality P.V.C. waste pipe with C.P. nut 32 mm dia., 900 mm long approved quality P.V.C. connection pipe with heavy brass C.P. nut including mending good all damages and painting the brackets with two coats of approved paint.(iii) 630 mm X 450 mm size
Supplying, fitting and fixing porcelain soap tray of approved make.(i) Recessed soap tray of size 150 mm X 150 mm
Supplying, fitting and fixing towel rail with two brackets.(a) C.P. over brass (iii) 25 mm dia. and 750 mm long
Supplying, fitting and fixing bib cock or stop cock.(a) (i) Chromium plated Bib Cock short body (Equivalent to Code No. 511 & Model - Tropical / Sumthing Special of ESSCO or similar).
(a) (ii) Chromium plated Bib Cock long body with wall flange with aerator (Equivalent to Code No. 512 & Model - Tropical / Sumthing Special of ESSCO or similar).
(b) (i) Chromium plated Stop Cock (Equivalent to Code No. 513(A) & 513(B) & Model - Tropical / Sumthing Special of ESSCO or similar).
Supplying,fitting and fixing approved brand 32 mm dia.P.V.C. waste pipe, with PVC coupling at one end fitted with necessary clamps.(iv) 1050 mm long, ground floor.
Total Amount
Please Enable Macros to View BoQ information
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 3.18 MB
STANDARD_BID_DOCUMENT_2911.pdf
Tender Documents • 0.54 MB
BOQ_2507726.xls
BOQ • 0.41 MB
Download all tender documents and submit your bid