Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹33.1 LAccepted-AOC | ₹33.1 L Quoted ₹35.2 L | L1 | Accepted-AOC L1 |
| 2 | L2₹38.8 LRejected-Finance GURUGRAM | GURUGRAM | HARYANA | 122001 | ₹38.8 L | L2 | Rejected-Finance L2 |
Tender Value
₹35.2 L
EMD Value
₹70,440
Closing Date
2 Feb 2026, 5:00 pmClosed
DEVINDER KUMAR KAUSHIK
Electrical Rohtak
Prov. 200KVA Transformer and HT line in sector-10, Bahadurgarh
2026_HBC_498265_1
2026F2D137EA 3134 4406 B991 2974A44A8377247HSV
Open Tender
Electrical Works
120 days
Bahadurgarh Bahadurgarh Bahadurgarh
2 documents required · 2 mandatory
₹1,000
₹70,440
Yes
3 Mar 2026
21 Jan 2026
3 Feb 2026
21 Jan 2026
2 Feb 2026
21 Jan 2026
[13.27]Structural steel work in single section, fixed with or without connecting plate, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. [Through Rate]
[13.32]Providing and fixing bolts including nuts and washers complete. [Through Rate]
[23.26.2]SAFETY ITEMS 2. Supply and erection of High Tension Voltage caution notice plate of size 250*200 mm in three languages. [Through Rate]
[24.1.1]EARTHING AND LIGHTENING ARRESTOR 1. Earthing with GL earth pipe 4.5 m long and 40 mm dia with masonry enclosures on the top etc. (but without charcoal or coke and salt) as required. [Through Rate]
[24.1.2]EARTHING AND LIGHTENING ARRESTOR 2. Extra for using salt and char coal/coke for pipe earth electrode as required. [Through Rate]
[24.1.8]EARTHING AND LIGHTENING ARRESTOR 8. Providing and fixing 25 mm x 3mm G.I. strip on surface or in recess for connections etc. as required with all labour and material. [Through Rate]
[24.2.8.14]LT CABLE 8.14. Supply and erection of aluminium lugs heavy duty including crimping etc. up to the entire satisfaction of the Engineer-in-charge of the work.300 sqmm [Through Rate]
[24.2.8.9]LT CABLE 8.9. Supply and erection of aluminium lugs heavy duty including crimping etc. up to the entire satisfaction of the Engineer-in-charge of the work. 95 sqmm [Through Rate]
S/E of 300mm2 single core aluminium conductor PVC insulated cable as per ISS: 1554/P-I completes in all respect up-to the entire satisfaction of E-I-C.
S/E of 100 Sqmm (Dog) ACSR conductor conforming to IS 398 (Part-II) 1976/1996, IS 4826-1976 IS 1521-1972 and IS 1778-1980 with latest amendments and erection of the same with accessories including stringing and sagging of conductor as well as jointing and binding with insulator at supports in all respect up to the entire satisfaction of E-I-C.
S/E of wooden cleats having 4 Nos. grooves for 300 Sqmm single core cable with Nut and bolts with all petty material up-to the entire satisfaction of E-I-C.
S/E of PVC unsheathed aluminum conductor cable single core 1100 volts grade in pipe of size 50 Sqmm excluding cost and erection of pipe.
Supply and erection of 11 KV Anti Climbing Device for 11/33 KV Line (with barbed wire 12 x 12 Gauge on existing PCC Pole complete in all respect upto the entire satisfaction of Engineer-in-Charge.
S/E of 11 mtr long PCC pole as per IS: 1678-1960 specifications, Dimensions 140mm x 200mm at top and 140mm x 400mm at bottom with working load of 400 Kg buried 2.20 m in ground or as per UHBVNL Specification.
S/E of 11 KV polymeric disc insulator 45 KN for 11 KV over head lines with fittings, ball and socket type and complete with galvanized strain clamps, bolts, nuts, washers etc. as required.
S/E of stay set for HT Line complete in all respect with stay wire Disc insulator comprising M.S. rod of 20mm dia 8’ long with stand 1000 Kg. load and threaded upto 250mm long with cross channel of size 450mm x 450mm made out of M.S. Channel 75x40mmx6mmx6mm up-to the entire satisfaction to E-I-C.
Supply stringing sagging 8 SWG G.I. earth wire as per complete in all respect to the entire satisfaction of Engineer-in-Charge conforming to IS 298/1978 and 7807/1973 and with latest amendment thereof.
S/E of cradle guards made of 8 S.W.G. G.I. wire for HT line complete in all respect.
S/E of fuse unit L.T. side of 200 KVA transformers complete with wooden board cleats, aluminum strips MS clamps and MS nut and bolts including all petty material required up to the entire satisfaction of Engineer-in-Charge
S/E of 11 KV G.O. switch suitable heavy duty with suitable copper male and female contents for 11 KV conforming to ISS: 1816/1972 and ISS : 2544/ 1963 with latest amendment thereof complete in all respect.
S/E of 11 KV lightening arrestor S/Stn type 9 KV 10 KA heavy duty type complete with MS nut and bolts including all petty material required upto the entire satisfaction of E-I-C.
S/E of 11 KV pin insulator polymeric type with 11 KV G.I. pin complete set on PCC pole of Make: Rashtriya/approved by state Electricity Nigam, conforming to IS: Part-II 1974 and IS: 2486 Part-I of 100mm GI pin to hold the insulator of 100mm GI pin to hold the insulator complete in all respect upto the entire satisfaction of E-I-C.
Supply, erection, testing and commissioning of L.T. Arial Bunched cable 120 Sqmm x 4C plus 95 Sqmm x1 core messenger wire P.V.C. sheathed on existing PCC pole, Conforming to IS standard and with latest amendments there to complete in all respect up-to the entire satisfaction of E-I-C. Make: Polycab/Havell’s /Grandlay
Supply and erection of P.G. clamp Al cast 2 bolt suitable for 100mm2 ACSR conductor (DOG) complete in all respect.
Supply, installation, testing, commissioning of 3 Phase 11KV/0.433 KV-250V, 200 KVA Oil immersed, naturally cooled, Aluminum Wound Outdoor type Distribution Transformers with CSP (Completely self protected ) features with external microprocessor based four pole MCCB 300Amp. To 400 Amp., 50kA strictly conforming to Nigam’s technical specification No. CSC-V/R-I/DH/UH/P and D/2010-2011 read with amendment thereof and as per relevant ISS as amended from time to time and losses conforming to 4 stars rating of BEE as per Approved Specification of DHBVN/UHBVN including installation of transformer on existing platform up-to the entire satisfaction of Engineer-in-Charge. Voltage Rated Frequency Permitted at 75ºC i) Maximum load looses at 50% load at 75ºC = 780 Watt ii) Maximum losses at 100% load at 75ºC = 2300 Watt iii) Warranty = 78/72 Months shall be one time The above losses are maximum allowable and there would not be any positive tolerance.
Please Enable Macros to View BoQ information
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.97 MB
BOQ_576824.xls
BOQ • 0.36 MB
OT0124229.pdf
Other Document • 0.51 MB
Download all tender documents and submit your bid