| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹23.0 LAccepted-AOC 38 49 D OLD IDGAH COLONY AGRA U P 282001 | AGRA | AGRA | UTTAR PRADESH | 282001 | L-1 | Accepted-AOC L-1 | |
| 2 | L-2₹24.0 L+₹88,425 (3.83%)Rejected-AOC 42 INDUSTRIAL ESTATE GWALIOR MP 474004 | GWALIOR | GWALIOR | MP | 474004 | L-2 | Rejected-AOC L-2 | |
| 3 | L-3₹25.3 L+₹2.2 L (9.52%)Rejected-AOC | L-3 | Rejected-AOC L-3 |
Tender Value
Refer Docs
EMD Value
₹50,700
Closing Date
11 Feb 2023, 6:00 pmClosed
GE I RND DELHI
MILITARY ENGINEER SERVICE, GARRISON ENGINEER (I) RND, LUCKNOW ROAD, TIMARPUR, DELHI-110054
PROVISION OF POWER SUPPLY (130 KW) AT HEAVY DROP SYSTEM (HDS) AT ADRDE, GANGA JAL WATER SUPPLY AT VIGYAN VIHAR PHASE-I AND II AT ADRDE AGRA, PROVN OF COVERED SHED WITH PAVER BLOCK IN TECHNICAL AREA AND LED LIGHTS IN NBC PROTECTED COMPLEX CUM MI ROOM
2022_MES_569402_1
GE/RND-90/AGR/2022-2023
Open Tender
Civil Works
Item Rate
180 days
Agra and Gwalior
Class-D, cat- a(i), a(ii), b(i)
2 documents required · 2 mandatory
₹500
GE I RND DELHI
₹50,700
Yes
25 Feb 2023
15 Dec 2022
13 Feb 2023
15 Dec 2022
11 Feb 2023
30 Jan 2023
Amount
Surface excavation not exceeding 30cm deep and averaging 15cm deep and getting out in soft/loose soil complete all as per specified and directed.
Excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5 m in depth in soft/loose soil for foundation etc or for shafts, wells, cesspits, manholes, pier holes laying of cable, etc. not exceeding 10 sqm on plan and getting out complete all as specified and directed.
Returning, filling in, including spreading, levelling, watering and well ramming soft/loose soil in layers not exceeding 25 cm complete all as specified and directed.
Removing excavated soil not exceeding 50m and depositing where directed at a level n exc. 1.5 m above the starting point complete all as specified and directed.
M&L for PCC 1:3:6 type C2 (40 mm graded stone aggregate) in foundations, filling and mass concrete etc complete all as specified and directed.
M&L for 75mm thick PCC 1:4:8, type D-2 (40mm graded stone aggregate) as in sub base of floors complete all as specified and directed.
M&L for Providing and laying 60mm thick factory made cement concrete M-35 grade paver blocks made by table vibratory method using PU moulds, glossy finish of approved colour, design & pattern, laying by vibratory compaction over and including 50mm thick bed of fine sand, including cutting paver blocks in required size and pattern, filling joints with sand and sweeping out surplus sand complete all as specified and directed.
M&L for Providing and laying factory made M-25 grade cement concrete kerb stone fixed in position to the required line, level and curvature including necessary earthwork, jointed with cement mortar 1:3, making joints with or without grooves, thickness of joints not more than 5 mm (except at sharp curves) complete all as specified and directed.
M&L for newly plastered and concrete surfaces over 10 cm width or girth and applying two coats of synthetic enamel paint complete all as specified and directed.
M&L for brick work with sub-class 'B' bricks straight or curved on plan exceeding 6m mean radius built in CM 1:6 complete all as specified and directed.
M&L for rendering 15mm thick plaster in CM 1:4 on fair faces of brick work or concrete surfaces finished even and smooth without using extra cement complete all as specified and directed.
M&L for rendering 15mm thick plaster in CM 1:4 on other than fair faces of brick work or concrete surfaces finished even and smooth without using extra cement complete all as specified and directed.
M&L for preparation of newly plastered surfaces of walls and applying two coats of cement base paint over a coat of base coat primer complete all as specified and directed.
M&L for granite work 18 to 20 mm thick of any type (table rubbed and polished) in steps, jambs, pillars, window cills, cooking platforms and like including pointing in white cement 1:2 using marble dust with admixture of pigment to match with shade of granite over and including 20mm thick screed bed or bedding layer in CM 1:6 complete all as specified and directed.
M&L for rounding to edges of stone slabs one edge, such as in steps, cooking platforms and other similar situations complete all as specified and directed.
S&F for framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc complete, drilled for fixing of steel sheeting or other covering confirming to Fe-290 (Gde E-165). Doors, etc to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings and hanging also fastening and fixing complete all as specified and directed.
S&F rolled steel sections confirming to Fe-290 (Gde E-165) as in main and cross beams, hip and jack rafters columns, purlins where connected to common rafters and running rails and guides for sliding doors fixed with angle cleats or other connecting plates complete all as specified and directed.
S&F plain or chequered plates confirming to Fe-290 (Gde E-165) square cut or notched (ordinary and counter sunk) forming holes, without any attachment complete all as specified and directed.
S&F structual steel work in tubular trusses including special shaped washer etc complete using ERW or induction butt welded tubes conforming to I. S.1161- 1979 grade St-240 complete all as specified and directed.
S&F welded steel wire fabric weight not exceeding 4 Kg per square metre to wood or steel members complete all as specified and directed.
S&F pre-painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/ cladding, fixed with self tapping screws complete all as specified and directed.
S&F pre-painted galvalume aluminum zinc coating GI based plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding, fixed with self tapping screws complete all as specified and directed.
M&L for preparation of new steel or iron surfaces over 10 cm width or girth and applying two coats of black bituminous paint over a coat of red oxide primer complete all as specified and directed.
M&L for preparation of new or previously untreated steel or iron surfaces of any description over 10cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed.
Supply and laying GI tubing 40mm bore galvanised medium grade of any length including all new fitting laid in trenches/floor with required cutting, threading etc complete all as specified and directed.
Dismantling wall and ceiling board (fibre, pulp or insulation etc) any thickness, including framework of any description complete all as specified and directed.
S&F elegant tile 5mm thick made of perforated cement fiber composite 595x595/295X1195/595X1195 covered with absorptive microfiber coating on the front side and Acoustics fiber on the back side, water resistance, fire resistant absorption coefficient upto 0.89 at 160 Hz tested as per ISO 354. The tiles are anti-sag and installed on T24 grid system of 0.6mm thick Main 'T' length minimum 3000mm, web minimum 35mm to be placed at 600mm center to center and secondary cross "T' of length 600mm web minimum 35mm inter locked, Wire Support for Main T to be taken at every 1200mm length wise and 600mm width wise, with a backing of 50mm 1000 GSM thick absorb wool tested as per Fire Retardant IS 15061-2002 for excellent results complete all as specified and directed.
Supply and laying 100mm dia bore galvanised steel tubing medium grade laid in trenches/under floor/in walls joined including necessary new fittings complete all as specified and directed.
S&F new 100mm bore sluice valve with flanged ends per IS-14846-2000, PN-1.6 including brass spindle and wheel all as specified class II, ISI marked with nut bolts and jointing material i.e. rubber gasket and testing complete all as specified and directed.
Demolition of concrete in ground floors and pavings not exceeding 15 cm thickness (below or above ground level) complete all as specified and directed.
M&L for PCC 1:2:4 type B1 using 20mm graded agregate as in coping in including necessary form work complete all as specified and directed.
Supplying and laying un-reinforced precast concrete cable cover, Class LV, Type I, flat size 250mmX150mmX40mm, for LT cable complete all as specified and directed.
Supply, laying, jointing & testing of 1100 volts grade, heavy duty, LT XLPE cable with PVC insulated aluminium conductor served with an inner sheating of PVC tape armound with galvanised steel wire or tape and overall PVC sheathed, 3.5 core, 300 Sqmm nominal cross section in service connection laid in loops/ducts, along wall/pole or under floor/road or laid in trenches complete all as specified and directed.
Supply and fix in repair tubes GI steel tubes, 'light grade' with all fittings laid in trenches or bore under road of 100mm dia, for UG cable protection complete all as specified and directed. Note :- Rate of bore under road if required is deemed to be included in quoted rate.
M&L for point wiring with 1.5 sqmm multi stranded PVC insulated unseathed copper conductor cable FRLS in and including PVC concealed conduit of size 20 mm dia for one light point or fan point or bell point controlled by one way switch on plastic laminated sheet 3mm thick using existing MS/CI sunken box including PVC insulated unsheathed 1.5 sqmm copper conductor FRLS continuous earth wire and connecting with earth dolly including necessary cutting chasing for concealing of conduit and making good the disturbed surface complete all as specified and directed.
M&L for point wiring for 3 pin socket outlet, 15 amps, independent, with 2.5 sqmm multi stranded PVC insulated unsheathed copper conductor FRLS cable in and including PVC conduit of size 20 mm dia plasitc laminated sheet 3mm thick including PVC insulated unsheathed 2.5 sqmm copper FRLS conductor continuous earth wire and connecting with earth dolly including necessary cutting chasing for concealing of conduit and making good the disturbed surface complete all as specified and directed.
S&F switch piano type 5 Amp one way AC 230 volts complete all as specified and directed.
S&F socket outlet 2 in 1, 5 pin 5 Amp and 15 Amp multi purpose socket outlet AC 230 volt complete all as specified and directed.
M&L Sub main wiring with single core PVC FRLS insulated cable 4x10 sqmm (Nominal dia) copper conductor multistrand and drawing in and including PVC conduit 25 mm dia ISI marked and 10 Sqmm multistrand copper conductor PVC FRLS green unsheathed cable for earth continuity complete all as specified and directed.
Supply, laying and testing PVC insulated, armoured, heavy duty, aluminium conductor cable 4 core 1100 volts grade of size 25 Sqmm laid in trenches/ ducts, floors, fixed to walls etc complete all as specified and directed.
M&L for clean dry fine sand custrioning for cable protection including gently punning around cables in trenches complete all as specified and directed . Note :- Punned thickness shall be measurement and paid (8cm below & 15cm above the cable).
Supplying & Laying Sub Class `B’ bricks old size with axis of the bricks perpendicular to the axis of the cable as in cable protection complete all as specified and directed.
S&F MCB SP 6 to 32 Amps 10 KA 'C' Series,240 V complete all as specified and directed.
S&F MCB TP 40 Amps 10 KA , 'C' Series 240 V complete all as specified and directed.
S&F MCB TPN 63 to 100 Amps 10 KA 'C' Series 415 Volts complete all as specified and directed.
S&F sheet metal enclosures Triple pole and earth enclosure with three pin & earth plug with socket complete including triple pole MCB 32 Amps complete all as specified and directed.
S&F sheet metal enclosures for DBs when MCB to used TPN 4 way double door powder coated factory made with separate neutral and earth links with IP 43 protection, fixed on wall /metal board/wooden board including making all incomming and outgoing connections with suitable copper lugs complete all as specified and directed.
S&F surface wall mounted 20 watt LED tube light fitting, box type with driver, holder with extruded aluminium housing provided for efficient heat dissipation with polycarbonate diffuser input voltage AC 230 V, 50 Hz complete all as specified and directed.
S&F ceiling rose of size 65x50mm 3 terminal AC 230 volt complete all as specified and directed.
S&F bluk head luminarie with LED 10 watt lamps Hexagonal shaped with engineering plastic housing and frame with opal PMMA defuser complete including disconnecting and taking out old unserviceable light fittings complete all as specified and directed.
Material and Labour for earthing with GI earth plate electrode 600mmx600mmx6mm thick buried in ground vertically to a depth not less than 2.25meters below ground level with top edge of the earth plate at a depth not lesss than 1.5 meter below the ground level, earth plate surrounded 15cm thick layers of common salt and charcoal dust starting from ground below 15 cm of earth plate and up to 15 cm above the same. GI plate connected with GI wire 4.00mm by means of nuts, bolts and washers. GI Wire laid in 20mm dia light grade GI pipe as protection from top of the plate up to test point (cost of protection pipe up to 7.5 meters from earth electrode will be included in the rates quoted by the contractor) as shown in electrical plate No. 03 of SSR Part-I with following:- (a) GI wire 4.00mm dia. (b) Watering pipe GI light grade 20mm dia from top of the earth electrode up to MS funnel with wire mesh embeded in floor of PCC earth pit. (GI Funnel should properly be tightned on GI watering pipe and embeded in PCC floor of earth pit with open top suitable for watering of earth pits) (c) PCC earth pit 30x30x30cm constructed in PCC 1:2:4 type B1 exposed surfaces smoothly finished with 15mm thick cement mortar 1:6 plaster including RCC pit cover 25mm thick re-inforced with 8mm dia bars 75mm centre to centre both ways with 2 Nos MS handles of 12mm dia suitable for carrying of pit cover.
Taking down carefully from boards/ outlet boxes, fitting and fixture such as switches, sockets, ceiling roses, lamp holders, brackets, ceiling fittings, bulk head fittings, tube light fittings, regulators, for reuse at site or carrying to the store etc complete all as specified and directed.
S&F LED Luminare recessed mounted, 15 watt, high lumen, energy saving , square shaped, extruded aluminium housing provided for efficent heat dissipation with polycarbonate diffuser and integrated electronic driver , connector block, etc. having ceiling cutout dimension 180mm x 180mm complete with all accessories internally prewired and including connecting up with three core flexible copper conductor cable of suitable size including necessary cutting/chasing of ceiling for fitting of light complete all as specified and directed.
S&F LED Luminare surface mounted ,18 watt, round LED panel white powder coated Aluminium housing and integrated electronic driver with LEDs to provide glare free symmetrical illumination complete with all accessories internally prewired and including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed.
S&F LED Downlighter recess mounted ,18 watt, round LED panel, pre die cast white powder coated Aluminium housing and integrated electronic driver with ceiling cutout dimension 220mm including necessary cutting/chasing of ceiling for fitting of light complete all as specified and directed.
S&F in repairs of bulk head luminarie with LED 10 watt lamps Hexagonal shaped with engineered plastic housing and frame with opal PMMA diffuser complete all as specified and directed.
M/s Mahesh Engineering Works
M/s SANGEETA ENGINEERS
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .