Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹12.8 LAccepted-AOC 21 JHAMRI 151 JHAMRI JHAMRI ROHTAK HARYANA 124142 UDYAM HR 07 0030314 | JHAJJAR | HARYANA | 124142 | L1 | Accepted-AOC BEING L1 BIDDER | |
| 2 | L2₹13.2 L+₹34,397 (2.68%)Rejected-Finance | L2 | Rejected-Finance REJECTED DUE TO L1 BID VALUE | |
| 3 | L3₹13.5 L+₹69,904.05 (5.45%)Rejected-Finance | L3 | Rejected-Finance REJECTED DUE TO L1 BID VALUE | |
| 4 | L4₹13.8 L+₹96,982.10 (7.56%)Rejected-Finance HAMILTONGANJ NETAJI PALLY NEAR ICE FACTORY DISTT ALIPURDUAR WEST BENGAL 735 214 | ALIPURDUAR | WEST BENGAL | 735214 | L4 | Rejected-Finance REJECTED DUE TO L1 BID VALUE | |
| 5 | L5₹14.3 L+₹1.4 L (11.1%)Rejected-Finance | L5 | Rejected-Finance REJECTED DUE TO L1 BID VALUE |
Tender Value
₹15.3 L
EMD Value
₹30,600
Closing Date
19 Feb 2020, 6:00 pmClosed
GE (AF) HASIMARA
GE (AF) HASIMARA PO HASIMARA DIST ALIPURDUAR PIN 735215
PROVN TO ROOF SHEET AND FLOOR TILING AT CERTAIN BLDG AND REPAIR TO ROOF LEAKAGE, JOINERY AND OTHER MISC WORK IN CERTAIN BLDG AT IMTRAT UNDER GE (AF) HASIMARA
2020_MES_318482_1
C/8370/19-20/E8
Open Tender
Civil Works
Item Rate
210 days
GE (AF) HASIMARA
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE (AF) HASIMARA
₹30,600
Yes
6 Mar 2020
25 Jan 2020
20 Feb 2020
25 Jan 2020
19 Feb 2020
8 Feb 2020
Amount
SCHEDULE 'A' PART-I Excavating in post holes (or similar holes) each n. exc 0.5 Cum, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers n. exc 25cm, watering and removing surplus soil to a distance n. exc 50m and making good surface in soft/loose soil complete all as specified and directed.
M & L for Plain cement concrete 1:4:8, type D-2 (using 40 mm graded stone aggregate) as in foundation, filling and mass concrete, etc complete all as specified and directed.
M & L for Brick work with sub class 'B' bricks, straight or curved on plan exc 6m mean radius, built in cement mortar 1:6 complete all as specified and directed.
M & L for brick work with sub class 'B' bricks, straight or curved on plan to any radius, built in cement mortar 1:4 as in half brick thick walls complete all as specified and directed.
S & F Rolled mild steel work as in Joist, channel, angle, or tee sections, fixed independently, without connecting plates, etc. (cut to ordinary lengths i.e. within 20mm of the length indicated) conforming to Fe-410-W (Gde-E-250) quality-B complete all as specified and directed.
S & F MS steel work in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I.S. 1161-1979 grade St-240 complete all as speicfied and directed.
S & F Rolled mild steel in Plates (plain or chequered) channels fo grade Fe 410-W (Gde-E- 250) quality-A, square cut or notched (ordinary and counter sunk) forming holes, without any attachment complete all as speicfied and directed.
S & F Mild steel screw bolts of 11 to 15 mm diameter of shank (machine made) with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, length of bolt exc 5cm and n exc 10cm long complete all as specified and directed.
S & F Pre-Painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as per manufacturer's instruction complete all as specified and directed.
S & F Pre-Painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in ridges/vally gutter, fixed with self tapping screws as per manufacturer's instruction complete all as specified and directed.
M & L for Plain cement concrete 1:2:4, type B-0, (using 12.5 mm graded stone aggregate) as in roof kerb or mud stop, founded or chamfered on edges incuding necessary form works etc complete all as specified and directed.
M & L for rendering 15 mm thick on fair faces of brick work or concrete surfaces in cement mortar 1:6 and finished the surfaces even and smooth without using extra cement complete all as specified and directed.
M & L for rendering 15 mm thick in two coats (10mm+5mm each) on fair faces of brick work or concrete surfaces in cement mortar 1:4, mixed with integral water proofing compound with weight of cement in top layer as per manufacturer's instructions and finished the surface even and fair without using extra cement complete all as specified and directed. (Note : WPC shall be measured and paid separately against respective item).
Supply only integral water proofing compound (ISI marked) complete all as specified and directed.
Demolition of un-reinforced cement concrete in ground floors and pavings n.exc 15cm thickness, (Below or above Ground level) and disposal of debris and rubbish to a distance n.exc 100m complete all as directed by the Engr-in-Charge
M & L for 75 mm thick, plain cement concrete 1:4:8, type D-2 (using 40 mm graded stone aggregate) as in sub-base of flooring, etc complete all as specified and directed.
M & L for non-skid, ceramic, coloured tiles 7 to 8 mm thick (square/rectangular) area of each tile exc 0.18 sqm but n.exc 0.36 sqm, in floors etc, including 15 mm thick screed bed in cement mortor 1:6 and set & jointed in neat cement slurry and pointed in white or coloured cement to match with the shade of tiles complete all as specified and directed.
M & L for glazed, coloured, ceramic, tiles of size (350mm x 250 mm/450mm x 350mm/300mmx450mm) x 6 to 7 mm thick, on vertical surfaces such as skirting, dados etc, including 10 mm thick bedding in cement mortor 1:4 and set & jointed in neat cement slurry & pointed in white or coloured cement to match with the shade of tiles complete all as specified and directed.
M & L for non-skid, ceramic, coloured tiles 7 to 8 mm thick (square/rectangular) area of each tile exc 0.18 sqm but n.exc 0.36 sqm, as in vertical surfaces as in skirting, dado etc, including 10 mm thick screed bed in cement mortor 1:4 and set & jointed in neat cement slurry and pointed in white or coloured cement to match with the shade of tiles complete all as specified and directed.
M & L for non-skid, ceramic, coloured tiles 7 to 8 mm thick (square/rectangular) area of each tile exc 0.11 sqm but n.exc 0.18 sqm, in floors etc, including 15 mm thick screed bed in cement mortor 1:6 and set & jointed in neat cement slurry and pointed in white or coloured cement to match with the shade of tiles complete all as specified and directed.
M & L for non-skid, ceramic, coloured tiles 7 to 8 mm thick (square/rectangular) area of each tile exc 0.11 sqm but n.exc 0.18 sqm, as in vertical surfaces such as skirting etc, including 10 mm thick screed bed in cement mortor 1:4 and set & jointed in neat cement slurry and pointed in white or coloured cement to match with the shade of tiles complete all as specified and directed.
M & L for Machine cut green marble slab flooring 18 to 20mm thick, laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including 15 mm thick screed bed in cement mortor 1:4 and rubbing, polishing complete all as specified and directed.
M & L for Preparation of new steel surfaces of any description, over 10 cm in width or girth, not otherwise described and applying two coats of synthetic enamel paint over a coat of red oxide, zine chrome primer complete all as specified and directed.
M & L for preparing newly plastered surfaces of internal walls, etc and applying two coats of distemper oil emulsion over a coat of alkali resistant primer complete all as specified and directed.
M & L for Preparation of newly plastered surfaces of walls and applying two coats of cement base paint over a coat of alkali resistant primer complete all as specified and directed.
Taking down chowkats or frame, n.exc 1.5 Sqm each with shutters (without taking off shutter from the frame) complete all as specified and directed.
Taking down chowkats or frames, exe 1.5 but n.exc. 4 Sqm in each with shutter (without taking off shutter from the frame) complete all as specified and directed.
Taking down shutters of any description exc 1 Sqm but n. exc 2 Sqm each complete all as specified and directed.
Demolition of brick work or stone / boulder masonry, built in cement mortar including all quoins, pillars etc stacking the serviceable bricks after removing mortar and cleaning for re-use and disposal of debris and rubbish to a distance n.exc 100m as directed by the Engr-in-Charge.
Taking down cement plaster on brick or stone walls etc including racking out joints, hacking for key, scrubbing down with water complete all as specified and directed
M & L for rendering 5 mm thick in cement mortor 1:3 on concrete surfaces as in ceilings (sunshed, chajja etc) and finishing surfaces even and smooth without using extra cement complete all as specified and directed.
Dismantling structural steel work including doors, gates but excluding framed truss etc. complete all as specified and directed.
M & L for Mild steel framed work such as grills, gratings, gates etc., with ends of bars shouldered and/or riveted, or forged into spikes, framed guard bar, barred iron doors, ladders, framed balusters, walk ways, railings, framework of water tanks and similar work conforming to Fe-410-0 Gde E-250 complete all as specified and directed.
S & F in repair Steel windows with side hung shutters including projecting type hinges with steel handle, and steel peg stay, complete with glazing bars, dovetailed or welded complete all as specified and directed.
S & F in repair Steel windows with side hung shutters including projecting type hinges with steel handle, and steel peg stay, complete without glazing bars, dovetailed or welded complete all as specified and directed.
S & F Stainless steel wire cloth. 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples complete all as specified and directed.
S & F 3 mm thick, sheet glass, ordinary quality and glazing with oil putty in square not exceeding 0.5 Sqm in each pane complete all as specified and as directed.
S & F 30 mm thick, Flush shutters, solid core construction, with block board core and plywood face panels, commercial type on both sides complete all as specified and directed.
S & F mild steel bands, straps, supports or stays of rain water, ventilating pipes including bolts, hooks (stay) for large gates, hook and pintel hinges, clamps, hold fasts, wall ties,flat iron fillets for securing wire mesh, wind tie, fan hook and similar work including necessary drilling bolting or riveting etc conforming to Fe – 290 Gde E – 165 complete all as specified and as directed.
M & L for plain cement concrete 1:3:6, type C-1 (using 20mm graded stone aggregate) for embedding holdfast, bed block, cills, etc including necessary form work complete all as specified and directed.
S & F 100 mm long, stainless steel butt hinges fixed with stainless steel hinge pin etc complete all as specified and directed.
S & F 150 mm long, Aluminium anodised, barrel tower bolts of extruded section complete all as specified and directed.
S & F 125 mm size, Aluminium handles, cast type, anodised complete all as specified and directed.
S & F Mild Steel sliding door bolts, 300 mm long, plate type, stove enamelled black, with bright bolts not less than 12mm dia with & including a minimum of 6 bolts and nuts, four on bolt plate and two on staple plate, etc complete all as specified and directed.
M & L for Mild steel Framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering, Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing complete conforming to Fe-290 (Gde E-165) complete all as specified and directed.
M & L for Preparation of new or previously untreated wood and wood based surfaces of any description, not otherwise described, over 10 cm width or girth and applying two coats of synthetic enamel paint (1st grade quality) over a coat of pink primer complete all as specified and directed.
M & L for preparation of new plastered surfaces of ceiling and applying three coats of white wash complete all as specified and directed.
M & L for preparing old decorated surfaces of ceiling, etc by bromming down or by steel wire brushing, scrapping down smokes soot, moulds, moss and efflorscent salt and treating oil and greasy spot and applying one coat of white wash complete all as specified and directed.
M & L preparing old decorated surfaces of walls, etc including cornices by bromming down or by steel wire brushing, scrapping down smokes soot, moulds, moss and efflorscent salt and treating oil and greasy spot and applying two coats of white wash complete all as specified and directed.
M & L for preparing newly plastered surfaces of walls, etc and applying three coats of white wash complete all as specified and directed.
M & L for preparation new external surfaces of wall, chajja, facia etc and applying two coats of water based acrylic weather proof exterior emulsion (exterior wall finish) paint over a coat of primer as per manufacturer's instruction complete all as specified and directed.
M & L for preparation old decorated external surfaces of wall, chajja, facia etc by complete removing old paints by mechanical scrubber without disturbing the plastered surfaces and applying two coats of water based acrylic weather proof exterior emulsion (exterior wall finish) paint over a coat of primer as per manufacturer's instruction complete all as specified and directed.
M & L for preparing old decorated surfaces of wall/chajja, etc including cornces by bromming down or by steel wire brushing, scrapping down smokes soot, moulds, moss and efflorscent salt and treating oil and greasy spot and applying two coats of cement base paint complete all as specified and directed.
M & L for preparing old decorated surfaces of wall, etc including cornces by bromming down or by steel wire brushing, scrapping down smokes soot, moulds, moss and efflorscent salt and treating oil and greasy spot and applying two coats of distemper oil emulsion complete all as specified and directed.
M & L for 75 mm thick, plain cement concrete 1:3:6, type C-2 (using 40mm graded stone aggregate) as in footpath/hardstanding, etc, finishing cement concrete surface even and fair without using extra cement including making joints with bitumastic filing in proportion of bitumen and sand 1:2 making impressions of expanded metal whilst the concrete is green complete all as specified and directed.
Taking up or down 15mm bore, Steel tubing and connections and keeping serviceable pipes in safe custody for reuse in the work after and including cleaning as directed.
Taking up or down 20mm bore, Steel tubing and connections and keeping serviceable pipes in safe custody for reuse in the work after and including cleaning as directed.
Supply, laying, connection and testing, 15mm bore, Steel water tubing, galvanised, medium grade with all fittings and fixed complete to walls and ceilings or laid in floors, etc complete all as specified and directed.
Supply, laying, connection and testing, 20mm bore, Steel water tubing, galvanised, medium grade with all fittings and fixed complete to walls and ceilings or laid in floors, etc complete all as specified and directed.
Refixing of 15mm bore old serviceable steel tubing and connections in new or old position with new fittings complete to walls and ceilings or laid in floors, etc complete as directed. (Note: Serviceable pipe shall be reused as obtained from serial item No. 57 above)
Refixing of 20mm bore old serviceable steel tubing and connections in new or old position with new fittings complete to walls and ceilings or laid in floors, etc complete as directed. (Note: Serviceable pipe shall be reused as obtained from serial item No. 58 above)
S & F in repairs, 15mm bore, Nipple suitable for HDPE water tank (Minimum weight 38gms) complete all as specified and directed.
S & F in repairs, 15mm bore, bib taps of PTMT, any colour high pressure, screwed for iron pipe and fixed (minimum weight 90 gms) complete all as specified and directed.
S & F in repairs, 15 mm bore, Stop valves, cast copper alloy, chromium plated, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions complete all as specified and directed.
Demolition of cement concrete (reinforced) in any description and in any position not otherwise specified provided for complete all as specified and directed (reinforcement cut as required to facilitate demolition).
M & L for Reinforced Cement Concrete 1:1.5:3, Type A-1 (Nominal Mix) (Using 20 mm graded stone aggregate) as in slab supported on walls, beams and columns in floors, roofs, landings, balconies, etc complete all as specified and directed. (Note : Reinforcement will be measured & paid seperately)
M & L for use & waste Form work to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200 mm thick (Horizonal or sloping) for flat rough finished surfaces of concrete complete all as specified and directed.
S & F TMT steel bars 6mm to 8mm dia., and over cut to length, bend to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips quality complete all as specified and directed.
M & L Cutting out cracks to V-section in existing roofs or terracing, cleaning out, wetting, grouting with cement and sand slurry 1:3 complete all as specified and directed.
S & F 1000 litres capacity rotational moulded polyethylene water storage tanks (Cylindrical vertical with closed top), hoisted and fixed in position including taking down old unserviceable one as specified in SSR Part I and directed.
S & F 20 mm bore, Ball valves high pressure of PTMT with epoxy coated Aluminium rod & high density plastic ball screwed for iron pipe and fixed. (Minimum weight - 210 gms) complete all as specified and directed.
Taking down rolling shutters of any description and of size n.exc 7 Sqm each and refixing in the same position after carrying out necessary repairs, oiling and greasing including replacement of guide channel and welding etc complete including replacement of mionr accessories to make shutter smooth functioning/movement complete all as directed by the Engr-in-Charge. (Note: Spare parts such as bearing, tension spring, gear operated lever and shaft etc shall be measured and paid seperately as supply only)
M & L for Preparation of old painted steel surfaces of any description, not otherwise described, over 10 cm width or girth and applying one coat of Synthetic enamel paint complete all as specified and directed.
Supply only ball bearing for rolling shutter suitable for 32 to 40mm suspension shaft complete all as specified and directed.
Supply only tension spring for rolling shutter suitable for 32 to 40mm suspension shaft complete all as specified and directed.
M & L Water proofing treatment on RCC roof etc. comprising with the following operation and as specified herein below and as directed:- (a) Taking down existing old tarfelt, bituminous compound, existing plastering including cleaning & removing debris to a distance exc 100m & n.exc.250m. (b) 15 mm thick plastering in cement mortar 1:3 mixed with water proofing compound (to be measured seperately) as per manufacturer instructions finished even & smooth. (c) Preparing & cleaning of fully dried cement plastered surface. (d) Applying one coat of cold bituminous primer to the plastered surface @ 300 ml per sqm conforming IS-3384 (e) A layer of APP based polymeric membrane membrane 3mm thick (minimum) weighing 3.5 kg per sqm reinforced with polyster non woven fabric (weighing not less than 160 gms/sqm) shall be applied over bituminous primer as specified above. Application of polymeric membrane shall be by torch application. The over lap shall be minimum 100 mm on transverse direction and 75 mm in longitudinal direction. (f) One coat of aluminium paint over the APP based membrane @ 0.11 Kg/Sqm
Excavation in trenches n.exc 1.5 m wide and n.exc 1.5 m in depth for foundation, etc and getting out in soft/loose soil complete all as specified and directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm as in soft/loose soil complete all as specified and directed.
Removing excavated material not exc. 50 m and depositing where directed at a level not exc 1.5 m above the starting point complete all as specified and directed.
M/S DEY ENTERPRISE
M/S ANIL KUMAR BAUL
MAJUMDER ENTERPRISE
CONSTRUCTION SHELTER
SRI HANUMAN PRASAD AGARWALLA
M/S ASHOK ENTERPRISE
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .