Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹31.4 LAccepted-AOC | L1 | Accepted-AOC L1 | |
| 2 | L2₹31.6 L+₹19,814.96 (0.63%)Rejected-AOC H NO 309 REHARI COLONY JAMMU DISTT JAMMU J K 180005 | JAMMU | JAMMU AND KASHMIR | 180005 | L2 | Rejected-AOC L2 | |
| 3 | L3₹33.4 L+₹2.1 L (6.58%)Rejected-AOC GROUND FLOOR F 11 PHASE II MAYAPURI WEST DELHI DELHI 110064 | DELHI | WEST DELHI | DELHI | 110064 | L3 | Rejected-AOC L3 | |
| 4 | L4₹33.9 L+₹2.6 L (8.20%)Rejected-AOC | L4 | Rejected-AOC L4 | |
| 5 | L5₹34.9 L+₹3.5 L (11.3%)Rejected-AOC | L5 | Rejected-AOC L5 |
Tender Value
₹41.1 L
EMD Value
₹82,300
Closing Date
6 Oct 2020, 6:00 pmClosed
GE Jammu
GE Jammu c/o 56 APO Pin-180003
CERTAIN SANCTIONED E/M WORKS AT DAMANA AND MIRAN SAHIB UNDER GE JAMMU
2020_MES_363653_2
GEJC-35/2020-21
Open Tender
Job Works
Item Rate
180 days
AOR of GE Jammu
Class D category b i
8 documents required · 8 mandatory
₹500
GE Jammu
₹82,300
Yes
28 Oct 2020
15 Sept 2020
8 Oct 2020
15 Sept 2020
6 Oct 2020
22 Sept 2020
Amount
S&F Servo Voltage Stabilizer 200 KVA for automatic operation, three phase naturally oil cooled indoor type and designed for input variation between 340 V to 480 V with output voltage stabilized at 415 with accuracy +2.5% and speed of correction 8 Volts per second and of capacity including 1st filling of transformer oil complete with provn of over load and short circuit protection, high low voltage, cut off and by pass arrangements etc all as specified and as directed.
M&L Test point terminal block made of GI earth strip of size 32 X 6mm complete fixing nut, bolts etc all as specified and as directed.
Aluminium strip 25 X 3.15mm with saddle and fixing screw etc for roof conductor and down conductors above ground all as specified and as directed.
Supply and lay cable XLPE insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 240 sqmm 3 1/2 core laid in trenches/ on wall/ on pole/ in air/ through pipe/ duct etc complete all as specified and directed by Engr-in-Charge. Notes: (i) Wherever cable fixing/connection, suitable thimble should be used as per site situation. (ii) Excavation and earth work, sand cushioning, brick work and GI pipe shall be measured and paid separately.
Excavation in trenches, n.exc. 1.5m wide and n.exc. 1.5m depth and getting out in for foundation of pole, stay, laying of cable and pipe etc all as specified and as directed.
Returning and filling in, including spreading, watering and well ramming in layers n.exc 25 cm thick each layer all as specified and as directed.
Removing excavated material to a distance n.exc 50m and depositing where directed at a level n.exc 1.50m above the starting point all as specified and as directed.
M&L for dry sand cushioning to under ground cable in trenches including spreading, levelling and hand punning complete all as specified and as directed.
Supply and laying common burnt clay building sub class 'B' bricks, laid over sand cushioning laid at right angle along with cable all as specified and as directed.
M&L for point wiring for one light/fan point/call bell point controlled by one 5 Amp switch with 1.5 Sqmm single core multistranded copper conductor FRLS, PVC insulated (unsheathed) heavy duty cable including continuous earth wire of size 1.5 Sqmm copper conductor multistranded FRLS, PVC insulated (unsheathed) drawn into and including new concealed PVC rigid/non metallic conduit and connecting with existing CI/pressed steel terminal boxes including 3.00mm thick hylam brand IS-2036 marked, laminated top sheet cover for mounting switches, sockets, fan regulators etc complete all as specified and as directed by Engr-in-Charge. Note:- (a) Wiring shall be done by using proper colour coding. (b) Earth wire shall be of green colour.
One light point controlled by one Amp switch one way all as specified and as directed.
M&L switch piano flush type single pole one way 5 Amp all as specified and as directed.
M&L ceiling rose surface bakelite white with three terminal including connecting and testing all as specified and as directed.
Making holes for 300mm exhaust fan of suitable shape and size into or through brick walls including plastering for making good to the original surfaces of any description disturbed including painting/distemper matching with the existing colour all as specified and as directed.
S&F exhuast fan of 300mm sweep 230V complete with louver shutter including fixing raw/plug/nut and bolts all as specified and as directed.
Supply, installation, testing and commissioning of diesel engine driven Air cooled/water cooled/liquid cooled naturally aspirated generating set of capacity 15 KVA, 415 Volts, AC supply, 50 Hz, 3 phase, 4 wire, 0.8 PF at NTP, with CPCB approved acoustic enclosure, speed 1500 RPM, mounted on common base plate with flexible coupling and meeting the requirement of IS-4722/BIS specification complete in all respect with extended warranty of 5 years with and including the following:- (a) Diesel Engine:- Air cooled/water cooled/liquid cooled naturally aspirated engine of adequate capacity at 1500 RPM under NTP condition with governor suitable to regulator speed of DG set from No load to full load provided with blower fan, 12 volts self starting system including maintenance free battery of 12 volts, 75 AH, charging dynamo/alternator, air cleaner, diesel oil filters, complete in all respect. (b) Fuel Tank:- Fuel tank of adequate capacity for 12 hours running with stop cock, drain plug and necessary fuel pipe, manufactured out of MS sheet, complete all as per manufacturer's recommendations.
(c) Alternator:- Alternator suitable for continuous operation generating 15 KVA at 1500 RPM, 415 Volts, 0.80 power factor (lag) suitable for 50 Hz, 3 phase, 4 wire system. The alternator is Synchronous and brushless type screen protected, revolving field, self excited, self regulated through an AVR. The alternator has the following features: + 1.0% voltage regulation (Max) in static conditions, IP:23 protection with insulation class H, Permissible overload of 10% for one hour in 12 hours of operation.
(d) Control Panel:- The control panel consists of the following parts:- (i) Generator set controller microprocessor based multifunctional with LEd display for engine water temperature, Lubricant oil pressure, Engine RPM, Engine shut down display, total hours run and suitable for protection against high water temperature, low lubricant oil pressure, over speed and battery charger failure. (ii) Digital multi functional meter with LED display all electrical parameters of individual phase such as voltage, current, frequency, KVA, KW, power factor and having RS 485 communication port/remote monitoring complete with appropriate CTs and control wiring.
(iii) MCCB 4 pole 415 Volts AC of suitable capacity with aluminium bus bar/suitable Amp rating copper cable all as per manufacturer recommendations. (iv) HRC fuses for protection as per standard engineering practice and manufacturer recommendations for protection of meters etc. (e) Electric Starter equipment:- The equipment ill comprise of the following:- (i) Maint free battery duly initially charge and battery lead of adequate cap. (ii) Starter motor. (iii) Starter gearing. (iv) Start/Stop push button. (v) Alternator/ Dynamo of suitable capacity to charge the batteries while DG set is running complete with auto cut out all as per manufacturer's recommendations. (f) PCC foundation including all civil works for DG set all as per manufacturer's recommendations and all as directed. (g) AMF Panel for 15 KVA complete with relay panel and switch gears for automatic starting on main failure, control panel having meter and sound proof canopy as per CPCB norms and foundation etc
M&L for replacement Earthing complete with galvanised steel earth plate electrode 60X60cmX6.3mm thick, buried directly in ground (earth pit not less 2.25 meters dep below ground level) with top edge of the plate not less than 1.5 meters below nomal ground level, connected to galvanised earth lead wire 4.0mm dia by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in Electrical plate No 3 connected to earthing test point all as specified or indicated including testing on completion complete all as specifed and as directed.
Supply and install on load change over switch 415V in sheet metal enclosure 4 pole of capacity 63 Amp on wall/ angle frame with necessary drilling and thimbles as required at site complete all as specified and as directed by Engineer-in-Charge.
Supply and lay XLPE insulated screened PVC bedded, galvanised steel strip or wire armoured electric power cable (heavy duty) 1100 Volt grade with stranded aluminium conductor of size 25 sqmm 3.5 core laid in trenches/ on wall/ on pole/ in air/ through pipe/ duct etc complete all as specified and directed by Engr-in-Charge. Notes: (i) Wherever cable fixing/connection, suitable thimble should be used as per site situation. (ii) Excavation and earth work, sand cushioning, brick work and GI pipe shall be measured and paid separately.
Supply, installation, testing and commissioning replacement of LT panel of suitable size for 3 Phase 415 Volt, outdoor weather proof vermin proof duly powder coated double door with back and front opening made out from 3.0 mm thick CRCA sheet with angle iron base frame of size 50X50X6mm cubical type complete with aluminium bus bar 125 Amp 4 way with proper color coding complete with PVC insulator, with IP 54 as per IS 13947 protection, fault rating 50 KA/1Sec, complete with following items including:-
MCCB 4 Pole, current rating 63 Amp, thermal setting adjustable 70%-100% breaking capacity 50 KA at 415 V, 50 Hz, 01 No as incomer
MCCB 4 Pole, current rating 63 Amp, thermal setting adjustable 70%-100% breaking capacity 36 KA at 415 V, 50 Hz, 02 No as outgoing
MCB isolator 40 Amps SPN 10 KA = 02 Nos outgoing
Indicator Lamps (LED type) showing R, Y, B phases - 01 Set
Angle iron base frame as required size as per above panel, total leg height 600mm and grouting inside PCC 150mm legs and made out of ISA5050, 50 X 50 X 6mm thick angle iron duly painted - 01 No
Necessary excavation and as required PCC 1:3:6 (40 mm graded aggregate) type C-2 for foundation of angle iron legs frame work complete - 01 Job
Internal panel wiring with suitable multistranded copper conductor PVC insulated and sheathed FRLS complete with copper thimble/ lugs.
Supply, installation, commissioning of hi wall split unit indoor/ outdoor complete with cordless remote control unit and with in built air ioniser and plasma filter for better indoor air quality with minimum 3 star rating, capillary copper tubing of suitable size as per site requirement and EER 3.2 of capacity 2 Ton complete all as specified and as directed.
Supply and fix Voltage Stabilizer for automatic operation, single phase naturally air cooled indoor type and designed for input variaton between 170 V to 250 V with output voltage stabilized at 230 Volt with accuracy of + 2.5% and of capacity 5 KVA all as specified and as directed.
Supply and draw sub main wiring in pairs of two run 16 sqmm single core PVC insulated, unsheathed, multistranded copper conductor cable 1100 Volt grade, draw through and including PVC conduit medium duty and accessories of 25mm size and fixed with PVC saddles and cadmium plated steel screws to the surfaces of the wall/ ceiling including one run of 10 sqmm single core PVC insulated unsheathed copper earth continuity conductor all as specified and as directed. Note:- Two runs of single core cable with one run of earth continuity conductor inclduing PVC conduit accessories shall be measured and paid as one length.
Supply and fixing copper cable PVC insulated 120 sqmm single core in red colour confirming to IS-7097 Part-I necessary thimbles as required at site complete all as specified and directed by Engr-in-charge.
Supply and fixing copper cable PVC insulated 120 sqmm single core in black colour confirming to IS-7097 Part-I necessary thimbles as required at site complete all as specified and directed by Engr-in-charge.
Supply and fixing copper cable PVC insulated 16 sqmm single core in red colour confirming to IS-7097 Part-I necessary thimbles as required at site complete all as specified and directed by Engr-in-charge.
Supply and fixing copper cable PVC insulated 16 sqmm single core in black colour confirming to IS-7097 Part-I necessary thimbles as required at site complete all as specified and directed by Engr-in-charge.
Supply and draw sub main wiring in pairs of two run 6.0 sqmm single core PVC insulated, unsheathed multistranded copper conductor cabel 1100 Volt grade, draw through and including PVC conduit medium duty and accessories of 25 mm size and fixed with PVC saddles and cadmium plated steel screws to the surfaces of the wall/ceiling including one run of 4 sqmm single core PVC insultated unsheathed copper earth continuty conductor all as specified and as directed. Note : Two runs of single core cable with one run of earth continuity conductor including PVC conduit accessories shall be measured and paid as one length.
S&F single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB 20 Amps complete all as specified and directed by Engr-in-charge..
Supply and fixing 24" wide galvanised cable tray including all accessories i.e nuts, bolts, washers, clamps turning tray etc as per site requirement with provision of pipe/angle from ceilling to tray for support and angles at walls complete all as specified and directed.
Supply and Fixing maintenance free chemical earthing system through specialised agency to obtain earth resistance less than one ohm by providing copper earth plate 90x60 cmx5 mm buried directly in ground level with top edge of the plate at a depth not less than 2.25 mtr below ground level earth plate surrounded from all sides by chemicals and earth enhancing compound and electrode connection by using copper strip 32x6 mm flat by means of bolts,checknuts and washers incl 40 mm bore protection pipe light grade for protection strip upto 3 mtr above ground level with required chemicals for earth enhancing compound complete all as specified and directed.
M & L for Test point terminal block made of gun metal or phosphorus bronze size 75x75x25 mm drilled and screwed including 3 no.s 8 mm dia 25 mm long hexagonal head screw complete all as specified and directed.
Supply & fix Earth continuity conductor copper strip of size 32x6mm flat strip fixed to wall on pattern or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc as required all as specified and as directed.
Supply and fix MCBs DB TPN 6 way double door all as specified and as directed.
Supply and fix MCB TPN "C" series 415 V 32 amps complete all as specified and directed.
Supply and fix MCB SPN "C" series 240 V 40 amps complete all as specified and directed.
Supply & Fixing Ceiling Fans 1200 mm sweep 240 volts 50 Hz, ISI marked complete all as specified and as directed.
Supply, fixing, connecting and commissioning and testing of Company Make (automatic and manual operation) power factor improvement panel of capacity 200 KVAR for 400KVA Transformer including interconnection with LT panel with appropriate size of electric cable for transformer (Outdoor/Indoor) type panel factory made, weather proof, dust and vermin proof (IP54/IP42) suitable for 1100 V/440 V grade 3 phase 50 HZ AC supply floor mounted, fabricated out of 14 SWG MS sheet and having four Nos angle iron legs made out of 40x40x 6mm 60 cm long angle iron below frame with front door and Side/Back opening having locking arrangement prewired with copper conductor PVC insulated flexible wire size 1.5 sq mm/extension strips and connected with suitable size thimbles, lugs duly painted with L&T grey epoxy powder coating after suitable chemical treatment, legs duly embedded in ground in PCC 1:3:6 type C-1 (using 20 mm graded crushed stone aggregate) of suitable size including locking arrangement suitable for mounting , with required sheet metal enclosures, thimbles, all as per Cat Part of APFC Panel : pfcos150k10snd of dvepl or Equivalent Make Tricolitre, L&T, legrand as specified and directed by Engr-in-Charge. The firms specified cannot authorize any other vendors to manufacture APFC Panels on their behalf failing which panels so manufactured will not be accepted. The panels manufactured by original manufacturer only (dvepl,tricolte,L&T.legrand) will be accepted & factory inspection will be done by GE/AGE at original manufacturer plant only and all other electric incoming and outgoing connections with PVC insulated multistranded flexible copper cable of suitable size and PVC flexible conduit medium quality as required and comprising of the following :-
Incoming feeder:-
Incommer MCCB 400 Amp , Three Pole, Termal based release with adjustable O/L ,Adj S/C Setting Class II Front Face, 36KA rupturing capacity, Ics=100%Icu, Isolation with Positive Break Indication with Double Break Contacts, Standard Extended Rotary Handle, Spreaders, Phase Barrier. - 1 No
Metering Section- Digital Ammeter (0-400) Amps, digital Volt Meter (0-500) Volts , RYB Indicating Lamps ,1 Set Control fuses, CTs. 3
Insulated Busbar of Aluminium of 400A Capacity for 3 phase, fixed on Insulators, Busbar Should be PVC Sleeved with red. Yellow. Blue Colour, Busbar Support should be of smc/dmc - 1 set.
Multi 14 Step 440V, 5A (144 x 144) microprocessor based power factor controller provided in the command module for target power factor setting, automatic adjustment of dead bank ratio, digital power factor display.
Outgoing feeder :-
Accessories for 1 KVAR Capacitor Bank - 1 Nos :- Capacitor Duty Contactor 1 kvar with Damping Resistors which limits inrush current 440 volt, 3phase , 50 hz , coil-220vac ,MCB TP 6 A having breaking capacity 10 KA with std. duty capacitor, on/off indicators , Start/stop Push button.
Accessories for 2 KVAR Capacitor Bank - 2 Nos :- Capacitor Duty Contactor 2 kvar with Damping Resistors which limits inrush current 440 volt, 3 phase , 50 hz , coil-220v ac ,MCB TP 16 A having breaking capacity 10 KA with std. duty capacitor on/off indicators , Start/stop Push button.
Accessories for 15 KVAR Capacitor Bank - 3 Nos :- Capacitor Duty Contactor 15 kvar with Damping Resistors which limits inrush current 440 volt, 3phase , 50 hz , coil-220vac ,MCB TP 32 A having breaking capacity 10 KA with std. duty capacitor on/off indicators , Start/stop Push button.
Ventilating fans of required size to dissipate the heat liberated by capacitor unites complete with automatic switching on/off of fans depending upon the temperature of the pane; 230v ac 1500 rpm,160 cu.m/h flying leads
Automatic Power Factor controller steps Relay Micro proccessor based for switchting ON and OFF of capacitors to Display of voltage ,current,Active power ,apparent Power display of COS Ø ,THD voltage ,THD current,alarm indication for defective step,low power factor and axcess temperature. The relay having volt free c/o contact,automatic detection and uses of optimum capacitor capable of 4 Quadrant operation and any phase offset requirement.Switching programm :LIFO combi Filter ,manual mode built in under and over voltage release with auto reset large voltage input band of 90V to 440 volt ,45 to 65 HZ,current measuring 10MA-5A suitable for CT x/1A andx/5A commissing without additional setting and programming.Three decimal power reading .Phasing out of fault capacitor bank Automatically.
All accessories prewired with suitable size copper Wire with stand high temperature, housed in cubical panel made out of 14 swg thick MS sheet factory made duly powder coated front and rear door open able with locking arrangement complete with foundation as required or recommended by manufacturer. Make of APFC Panel: confirming to Cat No:- pfcos150k10snd of dvepl or Equivalent Make Tricolite, dvepl,Legrand, L&T. Note: APFC Panel shall be manufactured by original manufacturer only. The firms specified cannot authorize any other vendors to manufacture APFC Panels on their behalf failing which panels so manufactured will not be accepted. The panels manufactured by original manufacturer only (dvepl,tricolte,L&T.legrand) will be accepted & factory inspection will be done by GE/AGE at original manufacturer plant only.
Supply, fixing, connecting and commissioning and testing of Company Make (automatic and manual operation) power factor improvement panel of capacity 100 KVAR for 200KVA Transformer including interconnection with LT panel with appropriate size of electric cable for transformer (Outdoor/Indoor) type panel factory made, weather proof , dust and vermin proof (IP54/IP 42) suitable for 1100 V/440 V grade 3 phase 50 HZ AC supply floor mounted , fabricated out of 14 SWG MS sheet and having four Nos angle iron legs made out of 40 x 40 x 6mm 60 cm long angle iron below frame with front door and Side/Back opening having locking arrangement prewired with copper conductor PVC insulated flexible wire size 1.5 sq mm / extension strips and connected with suitable size thimbles , lugs duly painted with L&T grey epoxy powder coating after suitable chemical treatment , legs duly embedded in ground in PCC 1:3:6 type C-1 (using 20 mm graded crushed stone aggregate) of suitable size including locking arrangement suitable for mounting , with required sheet metal enclosures, thimbles , all As per Cat Part of APFC Panel : pfcos100k8snd of dvepl or Equivalent Make Tricolitre, L&T,legrand as specified and directed by Engr-in-Charge The firms specified cannot authorize any other vendors to manufacture APFC Panels on their behalf failing which panels so manufactured will not be accepted. The panels manufactured by original manufacturer only ( dvepl,tricolte,L&T.legrand) will be accepted & factory inspection will be done by GE/AGE at original manufacturer plant only.and all other electric incoming and outgoing connections with PVC insulated multi stranded flexible copper cable of suitable size and PVC flexible conduit medium quality as required , and comprising of the following :-
Incoming feeder:-
Incommer MCCB 160 Amp , Three Pole, Termal based release with adjustable O/L ,Adj S/C Setting Class II Front Face, 36KA rupturing capacity, Ics=100%Icu, Isolation with Positive Break Indication with Double Break Contacts, Standard Extended Rotary Handle, Spreaders, Phase Barrier. - 1 No
Metering Section- Digital Ammeter (0-200)Amps, digital Volt Meter (0-500) Volts , RYB Indicating Lamps ,1 Set Control fuses, CTs. 3
Insulated Busbar of Aluminium of 200A Capacity for 3 phase,, fixed on Insulators, Busbar Should be PVC Sleeved with red. Yellow. Blue Colour, Busbar Support should be of smc/dmc - 1 set.
Multi 8 Step 440V, 5A (144 x 144) microprocessor based power factor controller provided in the command module for target power factor setting, automatic adjustment of dead bank ratio, digital power factor display.
Outgoing feeder :-
Accessories for 1 KVAR Capacitor Bank - 1 Nos :- Capacitor Duty Contactor 1 kvar with Damping Resistors which limits inrush current 440 volt, 3phase , 50 hz , coil-220vac ,MCB TP 6 A having breaking capacity 10 KA with std. duty capacitor, on/off indicators , Start/stop Push button.
Accessories for 2 KVAR Capacitor Bank - 2 Nos :- Capacitor Duty Contactor 2 kvar with Damping Resistors which limits inrush current 440 volt, 3 phase , 50 hz , coil-220vac ,MCB TP 16 A having breaking capacity 10 KA with std. duty capacitor on/off indicators , Start/stop Push button.
Accessories for 7 KVAR Capacitor Bank - 1 Nos :- Capacitor Duty Contactor 7 kvar with Damping Resistors which limits inrush current 440 volt, 3 phase , 50 hz , coil-220vac ,MCB TP 20 A having breaking capacity 10 KA with std. duty capacitor on/off indicators , Start/stop Push button.
Accessories for 10 KVAR Capacitor Bank -2 Nos :- Capacitor Duty Contactor 10 kvar with Damping Resistors which limits inrush current 440 volt, 3phase , 50 hz , coil-220vac ,MCB TP 25 A having breaking capacity 10 KA with std. duty capacitor on/off indicators , Start/stop Push button.
Accessories for 15 KVAR Capacitor Bank - 2 Nos :- Capacitor Duty Contactor 15 kvar with Damping Resistors which limits inrush current 440 volt, 3phase , 50 hz , coil-220vac ,MCB TP 32 A having breaking capacity 10 KA with std. duty capacitor on/off indicators , Start/stop Push button.
Accessories for 20 KVAR Capacitor Bank - 2 Nos :- Capacitor Duty Contactor 20 kvar with Damping Resistors which limits inrush current 440 volt, 3phase , 50 hz , coil-220vac ,MCB TP 50 A having breaking capacity 10 KA with std. duty capacitor on/off indicators , Start/stop Push button.
Ventilating fans of required size to dissipate the heat liberated by capacitor unites complete with automatic switching on/off of fans depending upon the temperature of the pane; 230vac 1500rpm,160cu.m/h flying leads
Automatic Power Factor controller steps Relay Micro proccessor based for switchting ON and OFF of capacitors to Display of voltage ,current,Active power ,apparent Power display of COS Ø ,THD voltage ,THD current,alarm indication for defective step,low power factor and axcess temperature.The relay having volt free c/o contact,automatic detection and uses of optimum capacitor capable of 4 Quadrant operation and any phase offset requirement.Switching programm :LIFO combi Filter ,manual mode built in under and over voltage release with auto reset large voltage input band of 90V to 400 volt ,45 to 65 HZ,current measuring 10MA-5A suitable for CT x/1A andx/5A commissing without additional setting and programming.Three decimal power reading .Phasing out of fault capacitor bank Automatically.
All accessories prewired with suitable size copper Wire with stand high temperature, housed in cubical panel made out of 14 swg thick MS sheet factory made duly powder coated front and rear door open able with locking arrangement complete with foundation as required or recommended by manufacturer. Make of APFC Panel: confirming to Cat No:- pfcos100k8snd of dvepl or Equivalent Make Tricolite, dvepl,Legrand, L&T Note: APFC Panel shall be manufactured by original manufacturer only. The firms specified cannot authorize any other vendors to manufacture APFC Panels on their behalf failing which panels so manufactured will not be accepted. The panels manufactured by original manufacturer only (dvepl,tricolte,L&T, Legrand) will be accepted & factory inspection will be done by GE/AGE at original manufacturer plant only.
Supply, fixing, connecting and commissioning and testing of Company Make (automatic and manual operation) power factor improvement panel of capacity 30 KVAR for 63KVA Trasformer including interconnection with LT panel with appropriate size of electric cable for transformer (Outdoor/Indoor) type panel factory made, weather proof, dust and vermin proof (IP54/IP 42) suitable for 1100 V/440 V grade 3 phase 50 HZ AC supply floor mounted , fabricated out of 14 SWG MS sheet and having four Nos angle iron legs made out of 40 x 40 x 6mm 60 cm long angle iron below frame with front door and Side/Back opening having locking arrangement prewired with copper conductor PVC insulated flexible wire size 1.5 sq mm / extension strips and connected with suitable size thimbles, lugs duly painted with L&T grey epoxy powder coating after suitable chemical treatment , legs duly embedded in ground in PCC 1:3:6 type C-1 (using 20 mm graded crushed stone aggregate) of suitable size including locking arrangement suitable for mounting , with required sheet metal enclosures, thimbles , all As per Cat Part of APFC Panel : pfcos100k8snd of dvepl or Equivalent Make Tricolitre, L&T,legrand as specified and directed by Engr-in-Charge The firms specified cannot authorize any other vendors to manufacture APFC Panels on their behalf failing which panels so manufactured will not be accepted. The panels manufactured by original manufacturer only ( dvepl,tricolte,L&T.legrand) will be accepted & factory inspection will be done by GE/AGE at original manufacturer plant only.and all other electric incoming and outgoing connections with PVC insulated multi stranded flexible copper cable of suitable size and PVC flexible conduit medium quality as required , and comprising of the following :-
Incoming feeder:-
Incommer MCCB 100 Amp , Three Pole, Termal based release with adjustable O/L ,Adj S/C Setting Class II Front Face, 36KA rupturing capacity, Ics=100%Icu, Isolation with Positive Break Indication with Double Break Contacts, Standard Extended Rotary Handle, Spreaders, Phase Barrier. - 1 No
Metering Section- Digital Ammeter (0-200)Amps, digital Volt Meter (0-500)Volts , RYB Indicating Lamps ,1 Set Control fuses, CTs. 3
Insulated Busbar of Aluminium of 125A Capacity for 3 phase,, fixed on Insulators, Busbar Should be PVC Sleeved with red. Yellow. Blue Colour, Busbar Support should be of smc/dmc - 1 set.
Multi 6 Step 440V, 5A (144 x 144) microprocessor based power factor controller provided in the command module for target power factor setting, automatic adjustment of dead bank ratio, digital power factor display.
Outgoing feeder :-
Accessories for 1 KVAR Capacitor Bank - 1 Nos :- Capacitor Duty Contactor 1 kvar with Damping Resistors which limits inrush current 440 volt, 3phase , 50 hz , coil-220vac ,MCB TP 6 A having breaking capacity 10 KA with std. duty capacitor, on/off indicators , Start/stop Push button.
Accessories for 2 KVAR Capacitor Bank - 2 Nos :- Capacitor Duty Contactor 2 kvar with Damping Resistors which limits inrush current 440 volt, 3phase , 50 hz , coil-220vac ,MCB TP 16 A having breaking capacity 10 KA with std. duty capacitor on/off indicators , Start/stop Push button.
Accessories for 7 KVAR Capacitor Bank - 1 Nos :- Capacitor Duty Contactor 7 kvar with Damping Resistors which limits inrush current 440 volt, 3phase , 50 hz , coil-220vac ,MCB TP 20 A having breaking capacity 10 KA with std. duty capacitor on/off indicators , Start/stop Push button.
Accessories for 10 KVAR Capacitor Bank -1 Nos :- Capacitor Duty Contactor 10 kvar with Damping Resistors which limits inrush current 440 volt, 3phase , 50 hz , coil-220vac ,MCB TP 25 A having breaking capacity 10 KA with std. duty capacitor on/off indicators , Start/stop Push button.
Accessories for 5 KVAR Capacitor Bank - 2 Nos :- Capacitor Duty Contactor 15 kvar with Damping Resistors which limits inrush current 440 volt, 3phase , 50 hz , coil-220vac ,MCB TP 16 A having breaking capacity 10 KA with std. duty capacitor on/off indicators , Start/stop Push button.
Accessories for 20 KVAR Capacitor Bank - 2 Nos :- Capacitor Duty Contactor 20 kvar with Damping Resistors which limits inrush current 440 volt, 3phase , 50 hz , coil-220vac ,MCB TP 50 A having breaking capacity 10 KA with std. duty capacitor on/off indicators , Start/stop Push button.
Ventilating fans of required size to dissipate the heat liberated by capacitor unites complete with automatic switching on/off of fans depending upon the temperature of the pane; 230vac 1500rpm,160cu.m/h flying leads
Automatic Power Factor controller steps Relay Micro proccessor based for switchting ON and OFF of capacitors to Display of voltage ,current,Active power ,apparent Power display of COS Ø ,THD voltage,THD current,alarm indication for defective step,low power factor and axcess temperature.The relay having volt free c/o contact,automatic detection and uses of optimum capacitor capable of 4 Quadrant operation and any phase offset requirement.Switching programm :LIFO combi Filter ,manual mode built in under and over voltage release with auto reset large voltage input band of 90V to 400 volt ,45 to 65 HZ,current measuring 10MA-5A suitable for CT x/1A andx/5A commissing without additional setting and programming.Three decimal power reading .Phasing out of fault capacitor bank Automatically. All accessories prewired with suitable size copper Wire with stand high temperature, housed in cubical panel made out of 14 swg thick MS sheet factory made duly powder coated front and rear door open able with locking arrangement complete with foundation as required or recommended by manufacturer. Make of APFC Panel: confirming to Cat No:- pfcos100k8snd of dvepl or Equivalent Make Tricolite, dvepl,Legrand, L&T Note: APFC Panel shall be manufactured by original manufacturer only. The firms specified cannot authorize any other vendors to manufacture APFC Panels on their behalf failing which panels so manufactured will not be accepted. The panels manufactured by original manufacturer only ( dvepl,tricolte,L&T.legrand) will be accepted & factory inspection will be done by GE/AGE at original manufacturer plant only.
All accessories prewired with suitable size copper Wire with stand high temperature, housed in cubical panel made out of 14 swg thick MS sheet factory made duly powder coated front and rear door open able with locking arrangement complete with foundation as required or recommended by manufacturer. Make of APFC Panel: confirming to Cat No:- pfcos50k8snd of dvepl or Equivalent Make ricolite,dvepl,Legrand, L&T Note: APFC Panel shall be manufactured by original manufacturer only. The firms specified cannot authorize any other vendors to manufacture APFC Panels on their behalf failing which panels so manufactured will not be accepted. The panels manufactured by original manufacturer only ( dvepl,tricolte,L&T.legrand) will be accepted & factory inspection will be done by GE/AGE at original manufacturer plant only.
Material & labour XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, 630sq. mm cross-sectional area 3.5 core laid in trenches/ on wall/ on pole/ in air/ through pipe/ duct etc complete all as specified and directed by Engr-in-Charge. Notes: (i) Wherever cable fixing/connection, suitable thimble should be used as per site situation. (ii) Excavation and earth work, sand cushioning, brick work and GI pipe shall be measured and paid separately.
Materials & labour XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, 185 sq. mm cross-sectional area 3.5 core laid in trenches/ on wall/ on pole/ in air/ through pipe/ duct etc complete all as specified and directed by Engr-in-Charge. Notes: (i) Wherever cable fixing/connection, suitable thimble should be used as per site situation. (ii) Excavation and earth work, sand cushioning, brick work and GI pipe shall be measured and paid separately.
Materials & labour XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, 35sq. mm cross-sectional area 3.5 core laid in trenches/ on wall/ on pole/ in air/ through pipe/ duct etc complete all as specified and directed by Engr-in-Charge. Notes: (i) Wherever cable fixing/connection, suitable thimble should be used as per site situation. (ii) Excavation and earth work, sand cushioning, brick work and GI pipe shall be measured and paid separately.
M/S A K ENGINEERS & CO.
Amit Enterprises
Jiwan Singh
M/S Bali Agencies
M/S KULBIR SINGH SODHI AND CO
ASHOK KUMAR SHARMA
SATISH AND CO
JINDAL BUILDERS
Bidder Name
M/S KULBIR SINGH SODHI AND CO
Jiwan Singh
SATISH AND CO
JINDAL BUILDERS
Amit Enterprises
ASHOK KUMAR SHARMA
M/S Bali Agencies
vishesh engineers
M/S A K ENGINEERS & CO.
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .