Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹7.3 CrAccepted-AOC B 12 VISHAKARMA JYOTI SUBHASH LANE MALAD E MUMBAI 400097 | MUMBAI SUBURBAN | MAHARASHTRA | 400097 | ₹7.3 Cr | L1 | Accepted-AOC Lowest |
| 2 | L2₹7.6 Cr+₹33.3 L (4.57%)Rejected-Finance | ₹7.6 Cr+₹33.3 L (4.57%) | L2 | Rejected-Finance Being Not Lowest |
| 3 | L3₹7.7 Cr+₹43.6 L (5.98%)Rejected-Finance 11 A KUTCHERY ROAD BALUGANJ AGRA 282001 UP | AGRA | UTTAR PRADESH | 282001 | ₹7.7 Cr+₹43.6 L (5.98%) | L3 | Rejected-Finance Being Not Lowest |
| 4 | L4₹8.2 Cr+₹87.3 L (12.0%)Rejected-Finance NOT SPECIFIED | ₹8.2 Cr+₹87.3 L (12.0%) | L4 | Rejected-Finance Being Not Lowest |
Tender Value
₹5 Cr
EMD Value
₹5.8 L
Closing Date
11 Sept 2023, 6:00 pmClosed
CE (AF) Gandhinagar
HQ CE (AF) Gandhinagar, Lekhawada Patia, Chiloda, Gandhinagar-382042
COMPLETION OF INCOMPLETE WORK FOR CONSTRUCTION OF MARRIED ACCN FOR DSC, NCs(E) AND CIVILIAN AT AF STATION MADH ISLAND
2023_MES_611113_1
84150 R and C
Open Tender
Civil Works
Lump-sum
365 days
GE (AF) Thane
All as per NIT and Tender Documents
8 documents required · 8 mandatory
₹3,000
GE (AF) Thane
₹5.8 L
Yes
7 Dec 2023
28 Jul 2023
15 Sept 2023
28 Jul 2023
11 Sept 2023
28 Aug 2023
31 Jul 2023 - 7 Aug 2023
Amount
NOTE: Schedule ‘A’ Part I to XII are under Ser No. 1.00 to 12.00 are Prepriced by MES. Bidders shall insert their lumpsum amount in the Green coloured field under Col-6 only.
Lump sum price worked out for BUILDINGS / STRUCTURES as listed in Sch 'A’ Part I.
Lump sum price worked out for EXCAVATION & EARTH WORK as listed in Sch 'A’ Part III
Lump sum price worked out for SITE CLEARANCE as listed in Sch 'A’ Part III
Lump sum price worked out for INTERNAL WATER SUPPLY as listed in Sch 'A’ Part IV
Lump sum price worked out for INTERNAL ELECTRIFICATION as listed in Sch 'A’ Part V
Lump sum price worked out for ROAD/PATH/HARD STANDING/ CULVERTS as listed in Sch 'A’ Part VI
Lump sum price worked out for SEWAGE DISPOSAL as listed in Sch 'A’ Part VII
Lump sum price worked out for AREA DRAINAGE as listed in Sch 'A’ Part VIII
Lump sum price worked out for BOUNDARY WALL & GATE as listed in Sch 'A’ Part IX
Lump sum price worked out for SOLAR WATER HEATER SYSTEM as listed in Sch 'A’ Part X
Lump sum price worked out for EXTERNAL WATER SUPPLY as listed in Sch 'A’ Part XI
Lump sum price worked out for EXTERNAL ELECTRIFICATION as listed in Sch 'A’ Part XII
SCHEDULE `A' PART-XIII MISCELLANEOUS ITEMS OF WORK (Note for items 13.00 to 84.00 The contractor shall quote his rate for each of these items separately. The estimated rate is left blank since the same is not prepriced by MES)
INTERNAL ELECTRIFICATION
S & F MCB DBSPN 4 Way vertical double door type with IP protection and powder coated sheet steel enclosure - 1 No (MAIN INCOMING DB For JCO - 2 Qtrs) alongwith following accessories:- (a) MCB SPN 40AMP - 01 No (b) MCB SP 32 AMP - 02 Nos (b) MCB SP 10A - 1 No
S & F MCB DBSPN 08 Way Horizontal double door type powder coated sheet steel encloure - 1 No (FOR SUB DB JCO Qtr) alongwith following accessories:- (a) ELCB 32AMP - 01 No (b) MCB SP 16A - 02 Nos. (c) MCB SP 10A - 03 Nos.
S & F MCB DBSPN 04 Way Horizontal double door type powder coated sheet steel enclosure - 1 No (FOR SCOOTER PARKING SHED) alongwith following accessories:- (a) MCB SPN 16A - 01 No (b) MCB SP 06A - 02 Nos.
S & F MCB DBTPN 4 Way vertical double door type with IP protection and powder coated sheet steel enclosure - 1 No (MAIN INCOMING DB For OR 4 Qtrs) alongwith following accessories:- (a) Isolator 4 Pole 63AMP - 01 No (Incoming) (b) MCB DP 32A - 4 Nos (4 Qtrs) (c) MCB SP 10A - 1 No (For Street lights & Security Lights)
S & F MCB DBSPN 08 Way Horizontal double door type powder coated sheet steel enclosure - 1 No (FOR SUB DB OR Qtr) alongwith following accessories:- (a) ELCB 32AMP - 01 No (b) MCB SP 16A - 02 Nos (c) MCB SP 10A - 04 Nos
S & F MCB DBTPN 4 Way vertical double door type with IP protection and powder coated sheet steel enclosure - 1 No (MAIN INCOMING DB For Civilian Type-I 3 Qtrs) alongwith following accessories:- (a) Isolator 4 Pole 40AMP - 01 No (Incoming) (b) MCB DP 32A - 3 Nos (3 Qtrs) (c) MCB SP 06A - 1 No (For Street lights & Security Lights)
S & F MCB DBSPN 08 Way Horizontal double door type powder coated sheet steel enclosure - 1 No (FOR SUB DB CIV Qtr) alongwith following accessories:- (a) ELCB 32AMP - 01 No (b) MCB SP 16A - 02 Nos (c) MCB SP 10A - 03 Nos
S & F MCB DBTPN 4 Way vertical double door type with IP protection and powder coated sheet steel enclosure - 1 No (MAIN INCOMING DB For Civilian Type-I 4 Qtrs) alongwith following accessories:- (a) Isolator 4 Pole 63AMP - 01 No (Incoming) (b) MCB DP 32A - 4 Nos (4 Qtrs) (c) MCB SP 06A - 1 No (For Street lights & Security Lights)
S & F MCB DBSPN 08 Way Horizontal double door type powder coated sheet steel enclosure - 1 No (FOR SUB DB CIV Qtr) alongwith following accessories:- (a) ELCB 32AMP - 01 No (b) MCB SP 16A - 02 Nos (c) MCB SP 10A - 03 Nos
S & F MCB DBTPN 4 Way vertical double door type with IP protection and powder coated sheet steel enclosure - 1 No (MAIN INCOMING DB For Civilian Type-II 3 Qtrs) alongwith following accessories:- (a) Isolator 4 Pole 40AMP - 01 No (Incoming) (b) MCB DP 32A - 3No (3 Qtrs) (c) MCB SP 06A - 1No (For Street lights & Security Lights)
S & F MCB DBSPN 08 Way Horizontal double door type powder coated sheet steel enclosure - 1 No (FOR SUB DB CIV Type II Qtr) alongwith following accessories:- (a) ELCB 32AMP - 01 No (b) MCB SP 16A - 02 Nos (c) MCB SP 10A - 03 Nos
S & F MCB DBTPN 4 Way vertical double door type with IP protection and powder coated sheet steel enclosure - 1 No (MAIN INCOMING DB For NCs (E) 4 Qtrs) alongwith following accessories:- (a) Isolator 4 Pole 63AMP - 01 No (Incoming) (b) MCB DP 32A - 4 Nos (4 Qtrs) (c) MCB SP 10A - 1 No (For Street lights & Security Lights)
Note :- (i) Approval of chemical (Calcium hypochlorine) shall be given after verification of test certifiate of chemical of various manufacture and other factor like chemical and safety and health hazard aspect of usage of chlororonation. (ii) The branch/make of the chlorination of chemical must be sealed in production and certified by Govt laboratory confirming compliance of specification suitable for dring water with a declaration from the laboratory that from the technical strength, stability, health safety and operation point of view this product is used for drinking water applications for consumption by humans and the brand.make of calcium hypochorite is suitable for drinking water chlorination and its sample has been teted by Govt Laboratory.
S & F MCB DBSPN 08 Way Horizontal double door type powder coated sheet steel enclosure - 1 No (FOR SUB DB NCs (E) Qtr) alongwith following accessories:- (a) ELCB 32AMP - 01 No (b) MCB SP 16A - 02 Nos (c) MCB SP 10A - 04 Nos
EXTERNAL ELECTRIC SUPPLY
S & F MCB DBSPN 04 Way Horizontal double door type powder coated sheet steel enclosure - 1 No (FOR CYCLE PARKING SHED) alongwith following accessories:- (a) MCB DP 16A - 01No (b) MCB SP 06A - 01No
Material and labour complete with PVC insulated telephone cable for indoor applications (0.5mm ATC) one pair including ISI marked 20mm dia PVC conduit concealed in wall with and including pressed steel terminal boxes not less than 1.6mm thick of required size with top cover 3mm thick of backclite.
S & F one pair telephone socket as specified and approved
S & F one television socket as specified and approved
S & F wiring complete with PVC insulated television cable for indoor applications one pair including ISI marked 20mm dia PVC conduit concealed in wall, pressed steel terminal boxes not less than 1.6mm thick required size with top cover 3mm thick.
S & F electronic meter tamper proof of rating 10 to 40 Amps micro processor based single phase with optical communication port confirming to IS 13779 all as specified and as directed by Engr-in-Charge.
S&F Street light luminaire 1X 28W of IP 43with aesthetically designed sheet aluminium housing and UV stabilised acrylic cover complete with lamp and internal connections including bracket all as directed.Make; Wipro Cat Part No. WSF 14128 SG 1 x 28 W FTL (T8) equivalent in Bajaj,CG.
S&F Compact Fluorescent Lamp fitting with holder of capacity of 13 W DF 3U 6500K with all accessories fixed on walls or on ceiling, on round block of size 80 mm dia and 40 mm depth open recessed type (2 Nos) and connecting up complete with 23/0.0076 (or equivalent size in mm) flexible three core twisted copper cable all as specified and directed by Engineer-in-Charge.
S&F CFL Decorative fitting of luminarie 1X 10W complete with lamp and internal connection including bracket all as specified and directed.Make; Wipro Cat Part No. WVF 90118 1 x 10 W Coated GLS or equivalent in Bajaj,CG.
ROAD/PATH/HARD STANDING & CULVERTS
Providing and laying dry lean concrete having min 7 days crushing strenght of 10 MPa over a prepared subgrade all as specified and as directed by Engr-in-Charge.
M&L for cement concrete work in pavement quality concrete (PQC) of minimum field flexural strength 25Kg/ Sqcm in field using cement as per mix design thickness of concrete upto 25cm all as specified and as directed by Engr-in-Charge
SEWAGE DISPOSAL
M&L for corrugated profiled double wall HDPE pipe 147mm bore as specified fixed with chemical as directed sewage pipe laying in ground Make Rex Polyextrusion Ltd.
M&L Package type sewage Treatment Plant of 30000 litres per day capacity details as under:- Design, supply, installation, commissioning and testing including all civil, electrical mechanical works as per OEM specifications for packaged sewage treatment plant based on Hybrid of Aerobic and Anaerobic or based on Aerobic process of capacity 30,000 litres per day consisting of fiber glass reinforced plastic (FRP) tank made by chop hoop winding process from suitable polyester resin and glass fiber with hollow ribbing of polymetric material of 90mm thickness encased on the outside of the tank with suitable polyster resin and fibre glass to make tank suitbale for underground application up to an over burden of 2.25 metres in soil having diamneter of 2.43 mtr with usual process variation and having a length of 11.061 mtr with usual process variation. The tank to have Zones-first Zone to work as anaerobic septic zone created with suitable partition of FRP with advanced polymeric media with a surface area 190 Sqm/Cum suitably encased in a polymeric net to allow free movement of the media within fixed space created by the net, the third zone to work as sedimentation zone in the remainder area of the tank Aerobic zone have Twin Lobe Air blower installed for providing air flow of minimum 1251 ltr/min by coarse aeration in the zone for speedy reductioin of BOD. Sedimentation zone have submiersible pump of the size of 1hp for pumping the activated sludge back to the anaerobic zone by way of PVC pipes of 50mm dia on a regular basis.
The media within fixed space created by the net, the third zone to work as sedimentation zone in the remainder area of the tank Aerobic zone have Twin Lobe Air blower installed for providing air flow of minimum 1251 ltr/min by coarse aeration in the zone for speedy reductioin of BOD. Sedimentation zone have submiersible pump of the size of 1hp for pumping the activated sludge back to the anaerobic zone by way of PVC pipes of 50mm dia on a regular basis. The whole plant to be controlled by automatic control panel made from sheet molded compound of size 900 x 400 x 1000mm consisting of other accessories such as PVC pipe fittings, 4 Nos FRP strap of 8000 mm length, 4 Nos turn buckle, 8 mtr wire rope, 4 Nos of conrete RCC block having dimention of 5530 x 300 x 300mm, 4 Nos manhole cover of 550mm size, 8 Nos eye bolt and 8 Nos of wire lock, The input and output characteristic of effluent sewage and treated sewage are as given below: -
Ser No. Particulars Input Output Sewage Effluent Treated Sewage Treated Sewage (a) Color Gray Clear (b) PH 6.5-8.0 6.5-8.0 (c) COD 600mg/l <100mg/l (d) BOD 275mg/I <30mg/l (e) SS 400mg/l <10mg/l (f) Colliform 10-10 Counts/100ml <100counts/100ml (g) Residial chlorine - > 1.0 mtr/ltr
EXTERNAL ELECTRICFICATIONS
Supply, install and commissioning indoor type transformer step up/down copper wound with laminated core, HT 11 KV, 3 phase LT 433 volts, 3 phase 4 wire all as per IS-2026 of capacity 200 KVA complete with standard accessories like off load tap changer LT and HT bushings, cable termination boxes for termination of HT and LT cable, raditor , conservator tank, silica gel breather assembly etc complete all as directed by Engr-in-Charge at site the transformer shall conforming to the relevant BIS / IS- 2026 1981 codes and comply with the Indian Electricity act and Indian Electricity rules.
Laying only cable XLPE insulated arnoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 150 sqmm 3.5 core all as specified and as directed by Engr-in-Charge.
Laying only cable XLPE insulated arnoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 50 sqmm 3.5 core all as specified and as directed by Engr-in-Charge.
Laying only cable XLPE insulated arnoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 16 sqmm 4 core all as specified and as directed by Engr-in-Charge.
All as per item No 42 above , but 10 sqmm 4 core
All as per item No 42 above , but 16 sqmm 2 core.
Note for Item No 40 to 44 :- (i) Excavation and earth work will be measured and paid separately. (ii) Cable will be issued under sch 'B' at MES store yard of AGE E/M Thane.
Supply and lay cable cover of size 250mm x 150mm x 40mm type-II all as specified and as directed by Engr-in-Charge.
S&F looping box fabricated out of CRCA sheet metal enclosure prewired complete fitted with terminal connector block bakelite 8 way of 20 Amps rating with shorting strip copper, fitted with one No of MCB, SP, 05 to 30 Amps, 240 volts for termination of incoming and outgoing cables, local connection to fittings complete all as specified and as directed by Engr-in-Charge conforming to IP 55 degree of protection.
Supply and fix street security light fitting T5 lamp type, 4x24 watts with accessories and prewired and including lamp, conforming to IP 65 degree of protection. Make Asian, Wipro, Philips, CG.
S&F of bracket made out tubing medicum grade 1.5m long 40mm dia bent to shape of offset angle upto 45 degree for fixing of secuiry / street light fittings including necessary MS clamps, nuts, bolts etc all as specified and as directed by Engr-in-Charge.
Supply and install, testing and commissioning LT feeder piller and (CPRI) approved) cubical type outdoor confirming to IS-8623 Part-I factory fabricated made out of 3mm thick CRCA sheet & suitable size to accommodate all accessories/ fittings, compartmentalized in construction to acoommodate incoming MCCB and aluminium bus bars of rating not less 1.5 times the rated cap of incoming MCCB and out going feeder. The TPN busbars shall be insulated with colour coded heat shrinkable sleeve and shall be mounted on DMC / epoxy insulator of size not leass that 50 x 50mm conical type at an interval of not more than 500mm throughout the length of the TPN busbar the incoming as well as outgoing MCCBs shall have copper extension links of current carrying cap not less than 1.5 times the rated capacity of individual feeders, the extension links shall be supported on DMC/epoxy insulators having provision for termination of incoming and outgoing cables. All extension links / interconnection shall be insulated with heat shrinkable colour coaded sleeves. The cubical shall have a bottom channel of size 75 x 40mm duly coated with zinc metal coating. A detachable predrilled gland plate of thickness not less than 3mm thick zinc metal coated should be used at the bottom for entry of armoured cable of adequate size with glands. The above panel shall be front and back openable lockable/ openable by key from both side and shall have louvers and air vent gasket for natural flow of air, 3mm XLPE adhesive type gaskit shall be used to make panel vermin proof and panel shall be cold zinc (for rust proof) sprayed of approved thickness coated complete as specified and consisting the following:-
EXTERNAL WATER SUPPLY
Supply and install pumping set, centrifugal, electric driven 3 phase 415 volts, delivery 20 LPS at 44m head complete with and including the following accessories with CI valve casting, carbon steel (45-C) shutter cast iron, KW rating / ICE frame size DB 65/26, 22/180M alongwith following:- Make Kirloskar or equivalent. (a) Suitable suction & discharge GI pipe heavy duty as recommended by manufacturer upto 10 m both side pressure gauge and delivery end of suitable capacity. (b) Suitable size of copper cable for connection of motor to starter. (c) Foundation of pump set as recommended by manufacturer.
Supply and install , testing and commissioning electro chlorination plant, including piping connections, pump electrolysis tank, rectifier etc of out put capacity 50 gm/hr. Maximum treated water at 1PPM FRC dosage per batch of 08 hrs, 400 cum No of electrolysis cells - 01 No AC supply. Make - Electro chlor - 50 of perfect chloro system of Nagpur Aqua or equivalent.
Supply and installation of silent Diesel Engine Driven generating set 415 volts, 3 phase, 4 wire, engine as per IS 10001/10002 and alternators as per IS - 13364 complete with necessary meters and sound proof canopy of capacity upto 20 KVA all as specified and directed.
Fixing only galvanized concertina coil duly stretched, maintaining a dia of 600mm dia and spacing between two adjoining coil not more than 150mm, Concertina coil placed in Y shape angle iron post erected over boundary wall and fixed to angle iron with 3mm dia GI bearer wire, complete all as specified and as directed at site. (NOTE: Length of coil along the pitch shall be measured as one unit length) Note :- (i) Concentina coil shall be issued under schedule 'B' as free for fixing only. (ii) For measurement and payment purpose of concertina coil, length parallel to wall shall be measured where coil fixed.
Earthing complete with copper plate electrode 60cm x 60cm x 3.15mm thick burried directly in ground (earth pit not less than 2.25m depp below normal ground level) with top edge plate not less than 1.5m deep below normal ground level connected to copper earth strip 20x4mm dia by means of bolts, nuts, check nuts and washers made of brass, 20mm dia GI pipe (med grade) for watering, 40mm dia GI pipe (light grade) for protection of earth trip, including necessary earth work in any type of soil, PCC (1:3:6) type CI concrete pit, PCC (1:3:6) type C1 precast cover (54 x 54 x 5cm) duly reinforced with including 8mm dia TMT bar @150mm c/c both ways, one lifting handle made of 8mm dia TMT bar, embeded in precast cover slab complete all as specified and shown in electrical plate No 5 of SSR Part-I including testing on completion.
DEFECT RECTIFICATION
Taking down cement plaster on brick/stone or concrete surface including racking out joints, hacking for key, scrubbing down with water to receive plaster, including removing debris/rubbish materials off the site complete all as specified and directed by Engineer-in-Charge.
Taking down chowkats or frames exc 1.5 sqm & n exc 4 sqm with shutters without taking off shutters from the frame and removing to store
M & L for rendering 20 mm thick in cement mortar 1:4 (15 mm thick backing coat and 5mm thick finishing coat) on fair faces of brick work or concrete surfaces including finished even and smooth without using extra cement with using water proofing compound (water proofing compound shall be measured and paid seperately) complete all as specified and directed by Engineer-in-Charge.
S&F Solid PVC door frame of size 50mm x 47mm made out of 5mm plain colour sheet reinforced with MS Square tube, suppling & fixing in opening as per specification & drawing
S&F Factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails. M.S. frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; Panelling of plain colour PVC sheet to be fitted in the M.S. frame welded / sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solventcement, suppling & fixing in the frame at site as per specification & drawing. Make Rajshree or Syntex.
Providing and executing injection/pressure grouting in cracks in the parent concrete by fixing PVC/Aluminium nipples at 150 mm to 200 mm distance or specified distances as per design and detailed specifications. Pressure grouting using low viscous epoxy grout Conbextra EP 10(M)- Moisture insensitive epoxy resin injection material supplied in 1.5 Litre pack which can grout gaps ranging from 0.25mm to 9mm, having mix density 1060 kg/m3,Compressive Strength(ASTM D695)-60/mm2, Tensile Strength(ASTM C 304-97)-20 N/mm2, Flexural strength(BS 6319 Part 4)-45 N/mm2. Pressure grouting shall be carry out after surface preparations includes fixing nipples and filling crakcs with epoxy mortar one day before grouting, injecting low viscous grout mechanically about pressure 3.5 - 7.0 kg/cm² , removing nipple after grouting and sealing with epoxy mortar etc complete as directed by EIC. Payment shall be made on actual grout consumed. HSE Guidelines : Conbextra EP10(M) : Contains resins which may cause sensitisation by skin contact. Avoid contact with skin and eyes and inhalation of vapour.Recommended to wear tight-fitting, dust-resistant, chemical splash goggles if airborne dust is generated, Wear protective gloves. Wear appropriate clothing to prevent any possibility of skin contact. Barrier creams provide additional skin protection. Keep away from sources of ignition - no smoking. Maintaine ample ventilation.
Taking down shutters of any description exc 1.00 sqm but n exc 2 sqm
S& F Plain, framed, panelled shutters (any number of panels), with panels of timber flat on both sides (feather edged), or of veneered particle board medium density, wood particle board with commerical face veneers: supplied and fitted to chowkats
S&F 100mm size Butt hinges, extruded aluminium alloy with galvanised mild steel hinge pin, anodised and fixed, type B-21
S&F 100 mm long aluminium extruded alloy handles fabricated type anodized
S&F 150mm long extruded aluminium alloy handles fabricated type anodized.
S&F 150mm long aluminium anodized barrel tower bolts of extruded section.
S & F MCB DBTPN 4 Way vertical double door type with IP protection and powder coated sheet steel enclosure-01 No (For main incoming DB for 04 QTRS) alongwith followimg accessories:- (a) Isolator 4 Pole 63 Amp-01 No(Incoming) (b) MCB DP 32 A- 04 Nos(04 QTRS) (c) MCB SP 10A-01 No(For street light and secuirity light)
S & F MCB DBSPN 08 Way Horizontal double door type powder coated sheet steel enclosure-01 No (For SUB DB OR QTR) alongwith followimg accessories:- (a) ELCB 32 Amp-01 No (b) MCB SP 16 Amp- 02 Nos (c) MCB SP 10A-04 No
M&L for cement concrete (1:4:8) type D2 (using 40mm graded stone agrregate) as in foundation filling, mass concrete of area drain all as specified and directed
M&L for Precast cement concrete with PCC (1:3:6) as using 20mm graded stone aggregate in block masonry with solid blocks exc 10cm in width and setting CM (1:6) all as specified and as directed
M&L for cement concrete (1:2:4) type B1 (using 20mm graded stone agrregate) as in coping including necessary form work and finishes the surfaces even without using extra cement complete all as specified and directed
M&L for rendering 10mm thick cement plaster over PCC block masonary surface in cement mortar (1:4) finished even and smoth without using extra cement complete all as specified and as directed
M&L for preparing newly plastered surfaces ,and applying 2 coats of Cement base paint over a coat of alkali resistent primer complete all as specified and directed by Engineer-in-Charge.
NOTE: Amount of credit of Rs. 263485.00 for retrieved materials is mentioned in schedule of credit on Srl Page No. 42 of tender documents in pdf form which will be deducted offline while acceptance of tender.
DARSHAN CONSTRUCTION Co.
R.C. Magla and Co.
United Sales Corporation
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .