Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹40.0 LAccepted-AOC 00 HAIDARPUR JAMALPUR ROAD SADAR JAUNPUR UTTAR PRADESH 222001 | JAUNPUR | UTTAR PRADESH | 222001 | 1 | Accepted-AOC L1 Bidder | |
| 2 | 2₹42.1 L+₹2.1 L (5.18%)Rejected-Finance SIMULBARI T E PO VILL SIMULBARI PS KURSEONG DIST DARJEELING PIN 734009 WEST BENGAL | SIMULBARI | DARJEELING | WEST BENGAL | 734009 | 2 | Rejected-Finance Other than L1 bidder | |
| 3 | 3₹60.2 L+₹20.3 L (50.6%)Rejected-Finance A 4 VIVEKANANDA SUPER MARKET 2ND FLOOR HILL CART ROAD SILIGURI 734 001 DIST DARJEELING W B | JALPAIGURI | WEST BENGAL | 734001 | 3 | Rejected-Finance Other than L1 bidder | |
| 4 | 4₹60.8 L+₹20.8 L (51.9%)Rejected-Finance RABINDRA NAGAR P O RABINDRA SARANI SILIGURI 734 006 DIST DARJEELING W B | JALPAIGURI | WEST BENGAL | 734006 | 4 | Rejected-Finance Other than L1 bidder | |
| 5 | 5₹62.3 L+₹22.4 L (55.9%)Rejected-Finance NEAR PAYAL CINEMA P O SEVOKE ROAD SILIGURI 734 001 | DARJEELING | WEST BENGAL | 734001 | 5 | Rejected-Finance Other than L1 bidder |
Tender Value
₹44.5 L
EMD Value
₹89,100
Closing Date
18 Apr 2025, 6:00 pmClosed
CWE Bengdubi
Headquarters Commander Works Engineer Bengdubi Post-Bengdubi Distt-Darjeeling (WB) PIN- 734424
REPAIR/ MAINTENANCE/IMPROVEMENT OF 33/11 KV HT MRS INCLUDING MAINTENANCE OF TRANSFORMER, VCBS SWITCH GEAR, HT CABLES OTHER MISC WORKS MILITARY STATION SUKNA UNDER GE SUKNA
2025_MES_702156_1
8280/S/E8
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
Sukna
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
GE Sukna
₹89,100
HQ CWE Bengdubi
13 Jun 2025
21 Mar 2025
21 Apr 2025
21 Mar 2025
18 Apr 2025
5 Apr 2025
28 Mar 2025
Amount
Excavation in trenches in soft/ loose soil not exceeding 1.5 metre wide and not exceeding 1.5m in depth for laying of LT under ground cables/ pipes/stay assembly and not exceeding 10 Sqm on plan & 1.5 metre in depth for pole etc, complete all as specified and as directed by the Engineer-in-Charge.
Returning, filling in, with approved earth (retrieved from excavation after removal of grass, vegetation etc) including spreading, watering and well ramming in layers not exc 25cm thick in layers, complete all as specified and as directed by the Engineer-in-Charge.
Removal of surplus soil to a distance not exceeding 50 metre and depositing where directed at a level not exceeding 1.5 metre above the starting point, complete all as specified and as directed by the Engineer-in-Charge.
M& L for Sand cushioning in trenches/ existing cable trenches for cushioning of underground cable including spreading, levelling, well ramming in layers not exceeding 25cm in thickness, completeall as specified and as directed by the Engineer-in-Charge.
Supplying and laying factory made (Make as approved by the GE) pre cast unreinforced concrete cable cover of class HV, type 1, with flat, size 300mm x 180 mm x 40 mm for cable protection in trenches, complete all as specified and directed.
Supply and fixing GI tubing, light grade, 100mm bore for protection of cable, under road crossing, across drain, along electric pole or floor /wall etc, complete including taking out existing pipe, complete all as specified and as directed by the Engineer-in-Charge. Note : Excavation & Earth work shall be measured & paid for separately.
Supply, laying and testing XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, HT electric power cables (heavy duty) with aluminium conductor 11000 volts grade (Earthed) of size 95 sqmm 3 core and including taking down old unsv, complete all as specified and as directed by the Engineer-in-Charge. Note:- Excavation and earth work, sand cushioning, protection covers, protection pipes and jointing kits including jointing materials shall be measured and paid separately under relevant items.
Supply, laying and testing XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, HT electric power cables (heavy duty) with aluminium conductor 11000 volts grade (Earthed) of size 120 sqmm 3 core and including taking down old unsv, complete all as specified and as directed by the Engineer-in-Charge.
Supply, jointing and testing in repairs, cable jointing kit for 11 KV (Earthed) grade cable for outdoor termination, heat shrink type joint, complete with and including jointing materials and accessories suitable for 11KV XLPE insulated armoured aluminium conductor cable of size 50Sqmm to 95 Sqmm, 3 core, complete all as specified and as directed by the Engineer-in-Charge.
Supply, jointing and testing in repairs, cable jointing kit for 11 KV (Earthed) grade cable for outdoor termination, heat shrink type joint, complete with and including jointing materials and accessories suitable for 11KV XLPE insulated armoured aluminium conductor cable of size 120 Sqmm to 185mm, 3 core, complete all as specified and as directed by the Engineer-in-Charge.
Supply, jointing and testing in repairs straight through(Outdoor) cable jointing kit (Heat shrinkable type) for 11 KV (Earthed) grade cable complete with and including jointing materials and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 50 Sqmm to 95 Sqmm and also including provision of aluminium thimbles, complete all as specified and as directed by the Engineer-in-Charge.
Supply, jointing and testing in repairs straight through(Outdoor) cable jointing kit (Heat shrinkable type) for 11 KV (Earthed) grade cable complete with and including jointing materials and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 120 Sqmm to 185 Sqmm and also including provision of aluminium thimbles, complete all as specified and as directed by the Engineer-in-Charge.
M&L for carrying out the complete routine test of Power Transformer 33 /11 KV prescribed below & thorough out servicing, maintenance and replacement of unserviceable spare parts such as, bushing with studs both HT and LT, Breather, Buccholz, Conservator Tank Glass and gasket etc of Power Transformers capacity 3.15 MVA, 33/11 KV including calibration of winding temperature Indicator and Oil Temperature Indicator of OLTC at 33/11 KV complete all as specified and as directed. Tests and inspection to be carried out (i) IR value test of all transformer and bushings. (ii) PI value test for 20 seconds and 120 seconds. (iii) No load current test. (iv) Magnetic balance and Voltage ratio test. (v) Short circuit test. (vi) Testing of tap changer. (vii) Tan/delta test of transformer. (viii) Testing and checking oil temp trip circuit, winding temp trip circuit, serviceability of bucholz relay trip etc (ix) checking the electrical/manual operation of tap changer mechanism, check the integrity of the active components /contact surface mating for all tap positions, voltage ratio test for all tap position etc (x) Check the functionality of auto tapchanger Motor including diverter switch devices. (xi) Calibration of OTI and WTI of the Xmer (xii) Functioning of all the tripping system/relays displayed on the control relay panel-such as differential o/c, earth fault, metering circuits and all other protection emanating from transformer - oil temp trip, OLTC trip, winding temp gauge trip, bucholz relay, inter trip etc, calibration of all the relays. (xiii) Testing of triping of buchholz relay and servicing, Testing and calibration of OTI and WTI of all the power xmer with R&C Panel shall be got done by the contractor from the authorised agency/ Rep of OEM or State Electricity Board as approved by the GE. Note: (a) Cost of all the testing equipment, labour charges to the Rep of OEM or Approved testing agency and other elements to make the entire system servicable shall be deemed to be included in the quoted rates and only payment for supply only of the relevent items of the schedule shall be measured and paid for separately in case these are ordered and provided as directed. The make of the items /materials shall be as specified in the items and in case not specified, the same as per existing make, suitable to match with the existing eqpt as approved by the GE. (b) All the Test Report shall be submitted by the contractor duly signed by Rep of auth testing agency approved by GE for testing before execute the items for payment of RAR. (c) Pre-commissioning testing/inspection to be carried out with presence of SEI/EI.
Supply Oil temperature indicator for 33/11 KV Power Transformer capacity 3.15 MVA as per existing model and size complete all as specified and directed.
Supply only winding temperature indicator for 33/11 KV Power Transformer capacity 3.15 MVA as per existing model and size complete all as specified and directed.
Supply only Motor contactor for OLTC as per sample at existing model and size complete all as specified and directed.
Material for rewiring of unserviceable all control wiring of OLTC of 33/11 KV Power Transformer of capacity 3.15 MVA with existing size of PVC Cable multistrand copper conductor complete all as specified and directed.
Supply only diverter switch of OLTC panel of 33/11 KV Power Transformer of capacity 3.15 MVA of any capacity including all connection accessories as per existing model and size complete all as specified and directed.
Supply only neoprene rubberised gasket washer (Head Gasket) compatible to fit with parts (Grade : 70C) for entire power Transformer capacity 3.15 MVA 33/11 KV all as specified and directed.
Supply only Magnetise Oil Guage (MOG) Glass including neoprine rubberised seal on conservator tank of 33/11 KV Power Transformer of capacity 3.15 MVA all as specified and directed.
Supply only capilary including prob for oil and winding temperatue indicator of 33/11 KV Power Transformer of capacity 3.15 MVA all as specified and directed please.
Supply only glass door, neoprene rubber gas kit, hinges of marshalling box of 33/11 KV Power Transformer of capacity 3.15 MVA all as specified and directed please.
Supply only transparent flange type Silica gel breather for main transformer size 3.3 Kg including silica gel in complete all as specified and as directed.
Supply only transparent flange type Silica gel Breather for main transformer size 1 Kg including silica Gel complete all as specified and directed.
Supply only HV porcealen bushes complete with brass stud and nuts, check nuts, cups etc., complete for transformers of 3150 KVA, 33/11 KV and removing burnt out/unserviceable item complete all as specified directed.
Supply only LV porcealen bushes complete with brass stud and nuts, check nuts, cups etc., complete for transformers of 3150 KVA, 33/11 KV and removing burnt out/unserviceable item complete all as specified directed.
M&L for Spray painting for the capacity of power transformers 3150 KVA, 33/11KV by preparing the surfaces and removing all type of grease, oil, dust and all other substance and applying one coat of approved colour synthetic enamel 1st grade finishing with light greay paint to main tank, Fins, OLTC and other parts of transformer complete all as specified and as directed.
Vaccume dehydration with hot filteration plant of old transformer oil at different locations, after filteration, Di electric strength shall not be less than 60 KV in 2.5 mm gap electrode, complete all as specified and as directed. The contractor shall submit necessary Test Report for Di electric strength before dehyderation as well as after dehyderation from CPRI /Govt approved Lab as per relevant IS. The contractor's quoted rates shall also be deemed to include for this element. Note:- (i) Transformer Oil after dehydration shall be measured and considered for the payment under the item. (ii) The contractor must have own one dehydrated hot Vacuum Filtration plant of miniumum filtration capacity 500 ltr/hr. Tranformer oil Filtration plant with a provision of oil test set for immediate showing result. The plnt must have provision of on load filtration. (iii) Dehydration is taken for 02 Nos 33/11 KV Power transformer, 01 No 33/0.433 KV station Transformer & 11/0.433 KV Distribution Transformers.
Supply only transformer Oil conforming to IS-335 of 1993 (make : POWER OIL/HP/BP) for toping up /oil change of Transformers of any capacity at different locations, complete all as specified and as directed. Notes:- (i) The dielectric strenght of the transfomer oil shall not be less than 60 KV in 2.5mm gap electrode. (ii) Quoated rate shall also be deemed to include for testing of transformer oil from CPRI / Govt. approved lab as per relevant IS and submission of necessary test reports. (iii)Dehydration is taken for 02 Nos 33/11 KV Power transformer, 01 No 33/0.433 KV station Transformer & 11/0.433 KV Distribution Transformers.
M & L for comprehensive maintenance of 33 KV Isolators switch set of three at 33 KV Yard and taking shutdown from 33 KV S/S, disconnect from existing isolator carefully clean the male and female contact with CRC spray thorouhghly, tightening the nut, bolts and chek the female and male contact, clean and change the burn out insulator and apply petroleum jelly usage all the movable contact of isolator and repair or replacement all the worn out parts by new spare parts and reassembling the same in position and re-connecting the HT connection complete in functional order all as specified & directed. Note :- (i) Cost of spare parts i.e Female contact, P G Clamp etc shall be measured and paid separately. (ii) All the exising nut, bolt and washers of isolator should be replace with stainless steel nut, bolt and washers as per existing size at site . The cost of minor spare parts i.e nuts and bolts, washers , grommets, clips, pin etc essentially required to make the serviceable shall be deemed to be included in the quoted rate.
Supply only Female clamp suitable for 33 KV line isolator switch at 33 KV Main receiving Station, complete all as specified and directed.
Supply only PG Clamps/T Connector including nut and bolt of suitable size made of stainless steel suitable for 33 KV grid, complete all as specified and directed.
S&F Pin type, polymer insulator including one galvnished mild steel spindle, two galvanised iron washers and one galvanied iron nut, for 33 KV grade, complete all as specified and directed. MAKE: BHEL/Jaipuria Brothers/Pactil
S&F in repair Pin type, porcelain, vitreous, white , brown or green insulator including one galvanised mild steel spindle, two galvanised iron washers and one galvanised iron nut, for 33000 volts grade complete all as specified and as directed.
S&F in repair of polymer type single disc insulator assembly for tension with tension clamps for conductors,working pressure 33000 volts complete all as specified and as directed.
M&L for complete painting to steel gantry towers & beams, Vertical type structures, Horizontal Type structures, Steel tubular Pole 16 Mtr for Lightening arrestes and all cross arms section etc for 33 KV outdoor type switch yard at Adalpur Power House complete including all accessories and equipment, support, structrure including preparation of steel surface by scraping and removing all grease, oil, dust, rust etc and applying one coats best quality of aluminium paint complete all as specified and as directed. Note:- (i) All the painting work will be carried out in the 33 KV yard after proper shut down from WBSEB and as directed. (ii) All the painting work will be carried out as per direction of Engr-In-Charge/GE.(iii) Approximate Length of poles/Structures is 2800 RM.
S&F in repair synthetic rubber insulated mats 3 mm thick for voltage upto 33 kv for electrical purpose as per IS 15652 suitable for electric shock safety of size 2m x 1 m complete all as specified and directed .
S&F in repair synthetic rubber insulated mats 2.5 mm thick for voltage upto 11 kv for electrical purpose as per IS 15652 suitable for electric shock safety of size 2m x 1 m complete all as specified and directed .
M&L for carry out the routine test of existing 33 KV CT & PT (Set of Three) such as cleaning dust of the insulator, tightening and replace loose and burn out nut bolts in primary secondary connection, repair of oil leakage by using of oil seal including prepataion of old suface by removing rust, oil, grease etc and applying one coat approved colour synthetic enamel finishing light Greay paint outside the oil tank and secondary box all as specified and directed.prescribed in below:- (i) IR value test of CT & PT, (ii) WR Value of windings, (iii) Polarity test of CT & PT, (iv) Knee Point test. (v) Turn Ratio Test of CT & PT. Note: (a) Cost of all the testing equipment, labour charges to the Rep of OEM or Govterment approved testing agency and other elements to make the entire system servicable shall be deemed to be included in the quoted rates and only payment for supply only of the relevent items of the schedule shall be measured and paid for separately in case these are ordered and provided as directed. The make of the items /materials shall be as specified in the items and in case not specified, the same as per existing make, suitable to match with the existing eqpt as approved by the GE. (b) All the Test Report shall be submitted by the contractor duly signed by Rep of auth testing agency approved by GE for testing before execute the items for payment of RAR. (c) The cost of paint and other spare parts and material shalll be deemed to be included in the quoted rate.
M&L for routine test servicing and repair/maintenance of 33 KV VCB type PCOB-36, 36KV/1250 Amp outdoor type VCB alongwith tripping system and carried out the following testing and repair for smooth operation :- (i) Testing of the IR value of breaker both in open and close position, (ii) Test the Continuity of breaker in closed position, (iii) Testing of Tripping and closing system of breaker, (iv) Sevicing and maintenance of spring charge motor, (v) Repair/Replacement of all burnout tripping & closing coil (vi) Repair/maintenance of Gear assembly, (vii) Servicing & repair/replacements of defective components of the breaker and panel, (viii) Functional Checks, (ix) Mechanism servicing and lubrication of the breaker (xi) Checking/repairing/rectification of the Control wiring, (xii) Power Connection checking and correction as required, (xiii) Insulation measurement of main circuit (xiv) Cleaning and greasing of mechanism, Operation, trip and close electrical and manual mode, Spring charging testing electrical and manual mode (xv) All the nuts bolts of VCB 33 KV shall be replace with suitable size of nut bolt and washers made of stainless steel complete all as specified and as directed. Note: (a) Cost of all the testing equipment, labour charges to the Rep of OEM or Govterment approved testing agency and other elements to make the entire system servicable shall be deemed to be included in the quoted rates and only payment for supply only of the relevent items of the schedule shall be measured and paid for separately in case these are ordered and provided as directed. The make of the items /materials shall be as specified in the items and in case not specified, the same as per existing make, suitable to match with the existing eqpt as approved by the GE. (b) All the Test Report shall be submitted by the contractor duly signed by Rep of auth testing agency approved by GE for testing before execute the items for payment of RAR. (c) Pre-commissioning testing/inspection to be carried out with presence of SEI/EI.
Supply only closing coil assembly 30 V DC for 33 KV VCB complete all as specified and directed .
Supply only tripping coil assembly 30 V DC for 33 KV VCB complete all as specified and directed .
Supply only spring charging Motor with Gear Assembly matching with the existing 33 KV VCB system complete all as specified and directed .
Supply only spring charging Motor only matching with the existing 33 KV VCB system complete all as specified and directed .
Supply only Auxiliary Relay : Type VAA, Model – VAA32ZG80 13 BGH, 30 Volt DC of existing make complete all as specified and directed .
Supply only Auxiliary Relay : Type VAA, Model – VAA ll YF8006AH(M), of existing make complete all as specified and directed .
Supply only Auxiliary Relay : Type VAA, Model – SPECM2YF251A(VAAII) of existing make complete all as specified and directed .
Supply only Over Current Relay (Inverse) capacity 10 Amps type CDG 31 Model CDG 31 EG011SBCH of existing make complete all as specified and directed .
Supply only Over Current Relay (Inverse) capacity 4 Amps type CDG 31 Model CDG 31 EG011SBCH of existing make complete all as specified and directed .
Supply only PT Fuse 33 KV complete all as specified and directed .
Supply only motor cut off limit switch (Cherry Type) for 33 KV VCB breaker 630/400 Amp, 26.3 KA as per smaple in site complete all as specified and directed.
Supply only contactor for 33 KV VCB breaker 630/400 Amp, 26.3 KA, auxiliary Volt 110V DC as per smaple in existing site complete all as specified and directed.
Supply only crank lever with bolt for 33 KV VCB breaker 630/400 Amp, 26.3 KA as per smaple in site complete all as specified and directed.
Supply only set of O ring for pole for 33 KV VCB breaker 630/400 Amp, 26.3 KA as per smaple in site complete all as specified and directed.
Supply Vaccum interrupter bottle for VCB 33 KV, 1250 Amps complete all as specified and directed. Make: ABB/Ashida/Schneider/Siemens.
M&L for Servicing of 33 KV C&R and RTCC Panel bay marshall box as per existing make alongwith operating mechanism system and carried out the fwg repair for smooth operation :-(a) Cleaning and greasing of mechanism, (b) Testing of all triping circuit manually and through breaker controller switch such as high oil temp, high winding temp, Buchholz relay triping etc. (c) Testing and Repair/replacement of unsv relay. (d) Testing tap changing through RTCC panel in both mode automatic and manual. (e) Cleaning dust with vaccume cleaner and check and tightning of loose control/wiring of C&R and RTCC Panel. (f) Calibration of O/C & E/F relays, Aux-Relay, Bucholz, OTI, WTI, Alarm, Master Trip Relay, automatic voltage regulator relay using Primary and Secondary Injection testing) and repair/replace the burn out parts. (g) Check the DC supply healthy push botton and announciator. Note: (a) The cost of minor spare parts such as nuts, bolts, washer, ferules for control wiring, copper lugs, unless or otherwise mentioned here-in-after but essentially required to make the panel serviceable shall be deemed to be included in the quoted rate. (b) Cost of all the testing equipment, labour charges to the Rep of OEM or Govterment approved testing agency and other elements to make the entire system servicable shall be deemed to be included in the quoted rates and only payment for supply only of the relevent items of the schedule shall be measured and paid for separately in case these are ordered and provided as directed. The make of the items /materials shall be as specified in the items and in case not specified, the same as per existing make, suitable to match with the existing eqpt as approved by the GE. (c) All the Test Report shall be submitted by the contractor duly signed by Rep of auth testing agency approved by GE for testing before execute the items for payment of RAR. (d) Pre-commissioning testing/inspection to be carried out with presence of SEI/EI.
Supply only Automatic Voltage Regulating Relay (AVR) for 33 KV C&R Panel and RTCC panel as per sample in existing site is used to Regulate the secondary voltage of Power Transformers via On-Load Tap Changer (OLTC) complete all specified and as directed. Make ABB/Ashida/Schneider/Siemens
Material for rewiring of all control wiring of 33 KV C&R panel/RTCC Panel with existing size of PVC Cable multistrand copper conductor and ferules for identification with copper lugs complete all as specified and directed.
Supply of flush mounted high speed tripping relay suitable for 33 KV C&R panel aux volts 110 Volt DC making necessary cutting in the existing panel and necessary control wiring FRLS of size not less than 2.5Sqmm and providing Ferules for identification and necessary spares for fixing as per sample in site all as specified and directed. Make ABB/Ashida/Schneider/Siemens
Supply only LED Type indicating lamp colour RED for 33 KV C&R Panel suitable for 220/110 volts as per existing voltage and size complete all as specified and directed.
Supply only LED Type indicating lamp colour YELLOW for 33 KV C&R Panel suitable for 220/110 volts as per existing voltage and size complete all as specified and directed.
Supply only LED Type indicating lamp colour BLUE for 33 KV C&R Panel suitable for 220/110 volts as per existing voltage and size complete all as specified and directed.
Supply only LED Type indicating lamp colour WHITE for 33 KV C&R Panel suitable for 220/110 volts as per existing voltage and size complete all as specified and directed.
Supply only LED Type indicating lamp colour GREEN for 33 KV C&R Panel suitable for 220/110 volts as per existing voltage and size complete all as specified and directed.
Supply only LED Type indicating lamp colour AMBER for 33 KV C&R Panel suitable for 220/110 volts as per existing voltage and size complete all as specified and directed.
Supply only of trip and healthy circuit push buttons red, yellow, black and white with aux contacts 1 NO and 1 NC as per sample in site complete all as specified and directed.
S&F in replacement of Breaker Control Switch (TNC) for C7R panel return to neutral type 2 pole 2 way with off complete all as specified and directed. Make: L&T/Switron.
S&F in repair Hooter flush type 96X96 mm for C&R panel aux voltage 220/110 Volt DC complete all as specified and directed.
S&F of Mild steel Chequre plate of 5 mm thick or over in thickness of Gde Fe 410 W A in replacement of PCC type duct cover as directed by Engineer-in-charge for using as cable trench plate all as directed.
S&F in repairs outdoor type Marshaling Box of size 300 mmX500mmX300mm (over all dimension) made out of 3.00 mm thick CRCA sheet with front side openable, single hinged door with locking arrengement and powder coated finish both internal and external steel surfaces after necessary preparation of steel surfaces for connection of control cable of CT & PT & VCB of 33 KV mounted on steel structure at 33 KV switch yard including 40x6mm flat iron clamp and nut bolt ety complete all as specified and as directed.
S&F in repairs Danger notice plate of 1.6mm thick mild steel sheet, vitreous enamelled white, with letters, figures and conventional skull and bones in signal red colour and fixed with and including M.S.clamps, bolts and nuts of approved size for HT 33 KV, 25x20cm size, complete all as specified and directed.
Surface dressing n.exc 15 cm deep and getting out in soft/loose soil for cleaning and cutting of grass/bushes (at zero level) in and around the installation / yard including removal of all surplus soil all as directed.
Relaying of broken stone/metal aggregate of gaugeof any size deposited, spread and levelled in layers n.exc 30 cm thick complete all as specified and directed.
M&L for broken stone or boulders hardcore of gauge n. exc 63 mm, deposited, spread and levelled in layers n.exc 15 cm thick, watered and rammed to a true surface, complete all as specified and directed.
M&L for sand filling ducts of 33 kv switch yard complete all as specified and directed
M&L for carrying out the testing and periodical maintenance of battery of existing Battery bank and battery charger as and when required using testing equipments including changing of terminals, greasing of terminals and pouring of distilled water, tightening of loose connection in panel complete all as directed and producing the test result for recording purpose complete all as specified and as directed. Notes:- (i) The contractor is required to carry out the battery Tester as completely. (ii) Testing of all battery in the battery bank shall be measured as 'one unit'. (iii) All test results shall be submitted by the contractor to the Engr-In-Charge before claiming/releasing of RAR payment. (iv) For the purpose of testing, contractor shall deploy all equipments and apparatus/instruments at his own cost.
M & L in replacement of PVC insulated, PVC sheathed cable, galvanized steel strip or wire armoured, electric control cables (Heavy duty) with stranded copper conductor of size 2.5 Sqmm 2 core 1100 Volts grade, in the trenches /ducts/along wall / floor /pole/equipment /on floor etc, including taking out of existing cable, complete all as specified and directed.
M & L in replacement of PVC insulated, PVC sheathed cable, galvanized steel strip or wire armoured, electric control cables (Heavy duty) with stranded copper conductor of size 2.5 Sqmm 4 core 1100 Volts grade, in the trenches /ducts/along wall / floor /pole/equipment /on floor etc, including taking out of existing cable, complete all as specified and directed.
M & L in replacement of PVC insulated, PVC sheathed cable, galvanized steel strip or wire armoured, electric control cables (Heavy duty) with stranded copper conductor of size 2.5 Sqmm 12 core 1100 Volts grade, in the trenches /ducts/along wall / floor /pole/equipment /on floor etc, including taking out of existing cable, complete all as specified and directed.
Removing of existing damage insulating material from LV Winding , Cleaning the winding and reinsulating the LV Winding with approved grade and make of insulating paper and heating the coil in the heat chamber to obtained desired result of insulating resistance complete and re-installation, complete all as specified and directed. .
Removing of winding of HV / LV side and rewinding with super enammeled copper wire/strip of existing size , gauge and weight of approved grade wire including necessary insulating material and heating the coil in the heat chamber to obtained desired result of insulating resistence complete and re-installation, complete all as specified and directed. Note for Item No. 39 &40:- (i)This item is catered for rewinding of Distribution Transformers only. (ii) Contractor shall be open the core assrmbly and segrigatted the serviceable / unser winding and shown to the EIC before and after incorportation to the TFR . (iii) Rates are inclusive of Opening of Transformer Top Cover, lifting of Core Assy, transportation to & from Sub-Station to workshop & back incl testing & Commissioning of the Transformer after repair/rewinding complete all as directed by Engr-In-Charge.
M & L for Painting of steel pole with cross arms, clamp of any length and shape for HT overhead line with single coat of aluminium paint including preparation of the existing surface including marking pole numbers in a 20 cm dia RED circle with yellow colour numbering with synthetic enamelled paint and strip marking of THREE RED AND THREE YELLOW alternatively of width 15 cm by fluorescent paint, from bottom of pole to 90 CM height and providng three nos of Red ,Yellow & Blue of reflecting strip of 25 mm width adhesive PVC tape around the pole at suitable height complete all as specified and directed.
M&L earthing complete with galvanised steel earth plate electrode of size 600 x 600 x 6 mm thick buried directly in ground in vertical position (earth pit not less than 2.25 m deep below the normal ground level) with top edge of the earth plate not less than 1.5 m below normal ground level, connected to galvanised earth lead of GI strip 32x6 mm by means of bolts, nuts, check nuts and washers of galvanised iron or steel, complete all as shown in Electrical Plate No. 3 of SSR Part-1 and connected to earthing test point and including dismantling of old one, complete all as specified and directed. Note: The unit rate shall also include for earth work in any type of soil, PCC 1:3:6 type C-1 chamber, RCC 1:1.5:3, type A1 cover slab, 50 mm thick reinforced with 8 mm dia TMT bar @ 140 mm C/C both ways, 10 mm dia plain bar lifting handle embedded in cover slab, 20 mm bore medium grade GI watering pipe, 40 mm bore GI medium grade earth lead rotection pipe, funnel, wire mesh, copper lugs, charcoal and common salt in alternate layer etc.
M&L earthing complete with copper earth plate electrode of size 600 x 600 x3.15 mm thick buried directly in ground in vertical position (earth pit not less than 2.25 m deep below the normal ground level) with top edge of the earth plate not less than 1.5 m below normal ground level, connected to copper earth strip of size 20x3 mm by means of bolts, nuts, check nuts and washers of copper, complete all as shown in Electrical Plate No. 3 of SSR Part-1 and connected to earthing test point and including dismantling of old one, complete all as specified and directed. Note: The unit rate shall also include for earth work in any type of soil, PCC 1:3:6 type C-1 chamber, RCC 1:1.5:3, type A1 cover slab, 50 mm thick reinforced with 8 mm dia TMT bar @ 140 mm C/C both ways, 10 mm dia plain bar lifting handle embedded in cover slab, 20 mm bore medium grade GI watering pipe, 40 mm bore GI medium grade earth lead rotection pipe, funnel, wire mesh, copper lugs, charcoal and common salt in alternate layer etc.
M & L for PCC earth pit chamber of internal dimension 300x300x300 mm and having wall thickness 100 mm using PCC 1:2:4 type B1 alongwith RCC 1:2:4 type B1 precast cover 50mm thick reinforced with 8 mm TMT bars both way & 100mm C/C including one lifting handle and dismantling of old one complete all as specified and directed.
Dismantling of defective 11 KV VCB ,400/800 Amps, Indoor VCB panel (Make: SCHNEIDER/ Crompton Greeves), servicing, repairing / replacement (as directed) of the unserviceable items such as closing / tripping coil assembly, spring charging motor and gear assembly, master trip relays, supervision trip relays, over current relays, overhauling and including rectification of the electrical & mechanical fault by the Service Engineer / Authorised Personnel of the Company after necessary cleaning and providing silicon grease to all the moving parts, also including adjustment of all springs /relays etc, commissioning of 11 KV VCB Panel CT,PT, Relays, VCB testing including CRM,Timer,IR Testing in VCB and ratio primary, IR, winding resistance, polarity testing in CT and PT and secondary current injection with 03 setting & tripping test with timing in relays and applying control voltage & testing all scheme logic with on/off trip operation, also checking metering and protection and annunciation with indication kit, making the VCB Panel and Testing of CT ratio, polarity test and connection of CT100-50/5 +5A by primary injection complete and Calibration of IDMT relay over current, earth fault and under voltage 100-50/5 +5A secondary injection complete and Preparation of surface of VCB panel board cubical in shape and applying one coat of SFRC paint.. (including VCB, its components, entire system) 100% serviceable, complete in all respects as specified and directed. Note: - Cost of all the materials, labour and other elements to make the entire system serviceable shall be deemed to be included in the quoted rate and only payment for supply only of the items listed here-in-below shall be measured and paid for separately in case these are ordered and provided as directed. The make of the items /materials shall be as specified in the item(s)and in case not specified, the same shall be of make SCHNEIDER or as per existing suitable to match with the existing VCB system as directed by the Engr-in-Charge.
Supply only over current relay and earth fault relay ( Make Schneider, Type Micon P111) suitable for 11KV 400A VCB Panel, complete all as specified and directed.
Supply only master trip relay ( Make Alstom) suitable for 11KV 400A VCB Panel, complete all as specified and directed.
Supply only supervision trip relay/ Trip ckt healthy ( Make Alstom) suitable for 11KV 400A VCB Panel, complete all as specified and directed.
Supply only single phase PT suitable for 11KV 400A VCB Panel, complete all as specified and directed. Note: The ratings of PT Ratio, Burden, Accuracy class etc shall be all as per existing PT & the decision of EIC & GE shall be final & binding .
Supply only single phase PT fuse suitable for 11KV 400A VCB Panel, complete all as specified and directed.
Supply only space heater 230V, AC 100W suitable for 11KV 400A / 630 A Ssuitable for VCB Panel, complete all as specified and directed.
Supply only multi voltage type indicator lamp suitable for 11KV 400A VCB Panel, complete all as specified and directed.
Supply only tripping coil 110V DC suitable for 11KV 400A VCB Panel, complete all as specified and directed.
Supply only closing coil 110V DC suitable for 11KV 400A VCB Panel, complete all as specified and directed.
Supply only spring charging gear motor 230V AC suitable for 11KV 400A/ 630A VCB Panel, complete all as specified and directed
Supply only buffer suitable for 11KV 400A VCB Panel, complete all as specified and directed.
Supply only TNC switch suitable for 11KV 400A VCB Panel, complete all as specified and directed.
Supply only digital type multifunction meter of size 96 x 96mm with built in adeeta switch(Make : SCHINEIDER) suitable for 11KV 400A VCB Panel, complete all as specified and directed
Supply only 11 KV CTs having CT ratio 100-50/5 +5A and output & accuracy class Core 1: 15 VA/CL1.0 and Core 2 :15 VA/5P10, STR: 13.1 KA for 1 sec, BIl 28/75KVP Frequency : 50 Hz, conforming to IS : 2705 1981. Make: Existing model of Crompton Greaves or equivalent.
Supply only post insulator suitable for 11KV 400A/ 630A VCB Panel, complete all as specified and directed
Supply only Vaccum interruptor for 11KV 400A/ 630A VCB Panel, complete all as specified and directed.
Supply only Auxiliary contractor 110 v DC 4 NO + 4NC. For 11KV 400A/ 630A VCB Panel, complete all as specified and directed
Supply only Diot for charging gear motor for 11KV 400A/ 630A VCB Panel, complete all as specified and directed
Supply only Limit Switch for 11KV 400A/ 630A VCB Panel, complete all as specified and directed
Supply only Play relay 110 volts DC for 11KV 400A/ 630A VCB Panel, complete all as specified and directed
Supply only Play relay base for 11KV 400A/ 630A VCB Panel, complete all as specified and directed
S&F in repair gang operated air break switches, triple pole, manually operated, mounted on three insulators double stack type and steel frame, with operating mechanism worked from ground level horizontal / vertical type for rating upto 400 Amps, 33000 volts complete with GI operating pipe of heavy duty,complete all as specified and directed.
R N SAH N CO (BID ID -3279417)
KARMIBRINDA (BID ID -3283873)
M/S DAWN ELECTRICAL INDUSTRIES (BID ID -3280360)
Janata Enterprises (BID ID -3284005)
MS ORIENT ENGINEERING WORKS (BID ID -3283803)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .