| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹34.9 LAccepted-AOC | ₹34.9 L | L1 | Accepted-AOC L1 Bidder |
| 2 | L2₹36.1 LRejected-Finance 31 TILAK NAGAR SRI GANGANAGAR 335001 RAJ | GANGANAGAR | RAJASTHAN | 335001 | ₹36.1 L | L2 | Rejected-Finance Not the lowest Bidder |
| 3 | L3₹36.3 LRejected-Finance 261 BHARAT NAGAR BATHINDA PB 151001 | BATHINDA | BATHINDA | PUNJAB | 151001 | ₹36.3 L | L3 | Rejected-Finance Not the lowest Bidder |
| Sl No | Description | Qty | Unit | Vinod Kumar Bajaj L1 | Singla Electricals L2 | Surindera Kumar Bansal L3 |
|---|---|---|---|---|---|---|
| 1.00 | Disconnecting HT & LT side cables of indoor/ outdoor distribution transformer capacity upto 125 KVA and earth strip from body and neutral of transformer mounted on two pole/four pole structure /staging and draining & collecting of oil in transformer oil barrel (free from any chemical content) ,dismantling of pipeline,conservator, HV-LV Bushings,opening of top cover , radiator , Tighting of complete tfr & re-tanking after fixing of new gasket and reconnecting transformer after complete repairs at site/workshop including installation & testing the transformer as per relevant IS complete all as specified and directed by Engineer-in-Charge
Note :1. Topping of oil , dehydration of transformer oil ,replacement of gasket , etc will be measured & paid separately under relevant items of this schedule.2. Barrel will be arranged by the Contractor. | 6 | Each Job | 8,000 ₹48,000 | 5,000 ₹30,000 | 5,000 ₹30,000 |
| 2.00 | All as per Srl item No. 01 here-in-before but transformer capacity 160 KVA to 315 KVA complete all as specified and directed by Engineer-in-Charge | 5 | Each Job | 9,000 ₹45,000 | 5,500 ₹27,500 | 5,500 ₹27,500 |
| 3.00 | All as per Srl item No. 01 here-in-before but transformer capacity 400 KVA to 630 KVA complete all as specified and directed by Engineer-in-Charge | 6 | Each Job | 10,000 ₹60,000 | 650 ₹3,900 | 6,500 ₹39,000 |
| 4.00 | M & L in replacement of HV Bushing of Distribution transformer of cap 25 to 125 KVA ,11/0.433 KV complete all as specified and directed by Engineer-in-Charge. | 2 | Set of Three | 1,500 ₹3,000 | 400 ₹800 | 900 ₹1,800 |
| 5.00 | All as per Srl item No. 04 here-in-before but LV Busing complete all as specified and directed by Engineer-in-Charge. | 2 | Set of Four | 1,000 ₹2,000 | 500 ₹1,000 | 700 ₹1,400 |
| 6.00 | All as per Srl item No. 04 here-in-before but HT brass bush rods including bolts, washers and packing sheet complete all as specified and directed by Engineer-in-Charge. | 5 | Nos | 2,200 ₹11,000 | 1,200 ₹6,000 | 2,000 ₹10,000 |
| 7.00 | All as per Srl item No. 04 here-in-before but LT brass bush rods including bolts, washers and packing sheet complete all as specified and directed by Engineer-in-Charge. | 5 | Nos | 1,800 ₹9,000 | 3,600 ₹18,000 | 1,500 ₹7,500 |
| 8.00 | All as per Srl item No. 04 here-in-before but Complete set of Gasket (Rubberised cork /Neoprina) complete all as specified and directed by Engineer-in-Charge. | 6 | Nos | 6,500 ₹39,000 | 500 ₹3,000 | 6,000 ₹36,000 |
| 9.00 | All as per Srl item No. 04 here-in-before but Tapping Switch Handle complete all as specified and directed by Engineer-in-Charge. | 1 | Nos | 2,500 ₹2,500 | 1,500 ₹1,500 | 2,000 ₹2,000 |
| 10.00 | All as per Srl item No. 04 here-in-before but Off Load Tapping Switch complete all as specified and directed by Engineer-in-Charge. | 2 | Nos | 5,000 ₹10,000 | 1,500 ₹3,000 | 5,000 ₹10,000 |
Updated dates
Tender Value
Refer Docs
EMD Value
₹70,000
Closing Date
1 Dec 2025, 6:00 pmClosed
HQ CWE SRI GANGANAGAR
HQ CWE POST BOX 48 SRI GANGANAGAR-335001 (Rajasthan)
REPAIR /MAINT OF HT UNDER GROUND CABLE, OVERHEAD LINE, GODs, VCBs, TRANSFORMERS AND CONNECTED WORKS AT FARIDKOT MIL STN
2025_MES_738277_1
CA NO CWE SGNR/TOKEN-79 OF 2025-26
Open Tender
Electrical and Maintenance Works
180 days
GE FARIDKOT
As per NIT
8 documents required · 8 mandatory
₹500
GE FARIDKOT
₹70,000
Yes
2 Feb 2026
3 Nov 2025
2 Dec 2025
3 Nov 2025
1 Dec 2025
17 Nov 2025
Amount
Disconnecting HT & LT side cables of indoor/ outdoor distribution transformer capacity upto 125 KVA and earth strip from body and neutral of transformer mounted on two pole/four pole structure /staging and draining & collecting of oil in transformer oil barrel (free from any chemical content) ,dismantling of pipeline,conservator, HV-LV Bushings,opening of top cover , radiator , Tighting of complete tfr & re-tanking after fixing of new gasket and reconnecting transformer after complete repairs at site/workshop including installation & testing the transformer as per relevant IS complete all as specified and directed by Engineer-in-Charge Note :1. Topping of oil , dehydration of transformer oil ,replacement of gasket , etc will be measured & paid separately under relevant items of this schedule.2. Barrel will be arranged by the Contractor.
All as per Srl item No. 01 here-in-before but transformer capacity 160 KVA to 315 KVA complete all as specified and directed by Engineer-in-Charge
All as per Srl item No. 01 here-in-before but transformer capacity 400 KVA to 630 KVA complete all as specified and directed by Engineer-in-Charge
M & L in replacement of HV Bushing of Distribution transformer of cap 25 to 125 KVA ,11/0.433 KV complete all as specified and directed by Engineer-in-Charge.
All as per Srl item No. 04 here-in-before but LV Busing complete all as specified and directed by Engineer-in-Charge.
All as per Srl item No. 04 here-in-before but HT brass bush rods including bolts, washers and packing sheet complete all as specified and directed by Engineer-in-Charge.
All as per Srl item No. 04 here-in-before but LT brass bush rods including bolts, washers and packing sheet complete all as specified and directed by Engineer-in-Charge.
All as per Srl item No. 04 here-in-before but Complete set of Gasket (Rubberised cork /Neoprina) complete all as specified and directed by Engineer-in-Charge.
All as per Srl item No. 04 here-in-before but Tapping Switch Handle complete all as specified and directed by Engineer-in-Charge.
All as per Srl item No. 04 here-in-before but Off Load Tapping Switch complete all as specified and directed by Engineer-in-Charge.
All as per Srl item No. 04 here-in-before butWinding Tamprature indicator complete all as specified and directed by Engineer-in-Charge.
All as per Srl item No. 04 here-in-before but Oil temperature indicator heavy duty 0-150 degree centigrade complete all as specified and directed by Engineer-in-Charge.
All as per Srl item No. 04 here-in-before but Brass valve of size 25mm complete all as specified and directed by Engineer-in-Charge.
M & L in replacement of HV Bushing of Distribution transformer of cap 160 to 315 KVA ,11/0.433 KV complete all as specified and directed by Engineer-in-Charge.
All as per Srl item No. 14 here-in-before but LV Busing complete all as specified and directed by Engineer-in-Charge.
All as per Srl item No. 14 here-in-before but HT brass bush rods including bolts, washers and packing sheet complete all as specified and directed by Engineer-in-Charge.
All as per Srl item No. 14 here-in-before but LT brass bush rods including bolts, washers and packing sheet complete all as specified and directed by Engineer-in-Charge.
All as per Srl item No. 14 here-in-before but Complete set of Gasket (Rubberised cork /Neoprina) complete all as specified and directed by Engineer-in-Charge.
All as per Srl item No. 14 here-in-before but Tapping Switch Handle complete all as specified and directed by Engineer-in-Charge.
All as per Srl item No. 14 here-in-before but magnetic oil level gauge complete all as specified and directed by Engineer-in-Charge.
All as per Srl item No. 14 here-in-before but Winding Temprature indicator complete all as specified and directed by Engineer-in-Charge.
All as per Srl item No. 14 here-in-before but Oil temperature indicator heavy duty 0-150 degre centigrade complete all as specified and directed by Engineer-in-Charge.
All as per Srl item No. 14 here-in-before but Brass valve of size 25mm complete all as specified and directed by Engineer-in-Charge.
M & L in replacement of HV Bushing of Distribution transformer of cap 400 to 630 KVA ,11/0.433 KV complete all as specified and directed by Engineer-in-Charge.
All as per Srl item No. 24 here-in-before but LV Busing complete all as specified and directed by Engineer-in-Charge.
All as per Srl item No. 24 here-in-before but HT brass bush rods incl bolts, washers and packing sheet complete all as specified and directed by Engineer-in-Charge.
All as per Srl item No. 24 here-in-before but LT brass bush rods incl bolts, washers and packing sheet complete all as specified and directed by Engineer-in-Charge.
All as per Srl item No. 24 here-in-before but Complete set of Gasket (Rubberised cork /Neoprina) complete all as specified and directed by Engineer-in-Charge.
All as per Srl item No. 24 here-in-before but Tapping Switch Handle complete all as specified and directed by Engineer-in-Charge.
All as per Srl item No. 24 here-in-before but Off Load Tapping Switch complete all as specified and directed by Engineer-in-Charge.
All as per Srl item No. 24 here-in-before but Oil temperature indicator heavy duty 0-150 degree centigrade complete all as specified and directed by Engineer-in-Charge.
All as per Srl item No. 24 here-in-before but Brass valve of size 25mm complete all as specified and directed by Engineer-in-Charge.
S&F in replacement of silica gel complete all as specified and directed by Engineer-in-Charge.
S&F in replacement of Air breather asembly including silica gel for distribution transformer ranging from 25 KVA to 630KVA as per existing ,11/0.433 KV complete all as specified and directed by Engineer-in-Charge.
Dehydration and filtration of existing transformer oil and cleaning of mud through high pressure flow oil pump using centrifugal plant to eliminate foreign particles and to improve di-electric strength not less than 55 KV per 2.5 mm electrode gap and to bring the acidity within the permissible limit complete all as specified and directed by Engr-in-Charge.
All as per Srl item No. 37 here-in-before but 160 KVA to 315 KVA complete all as specified and directed by Engineer-in-Charge.
All as per Srl item No. 37 here-in-before but 400 KVA to 630 KVA complete all as specified and directed by Engineer-in-Charge
S & F in replacement of switch air break gang operated, triple pole, mechanically operated, mounted on insulator and steel frame with operating machanism worked from ground level using heavy duty GI pipe, for current rating 200 Amps, outdoor type (conforming to IS specifications) HT 11 KV, triple pole with fixed contacts of phosphorous and bronze and a set of drop out HT fuse assembly, fuse carrier fitting, 12 insulator type mounted on MS channel operating rod with 7 lever pad lock arrangement complete along with D/O Fuse assembely with insulator and base frame. including disimantling old unserviceable switch air break gang operated device.
Prunning / trimming of tree branches upto 3.00mtr distance on both sides of over head lines including collection and removal from road complete all as specified and directed by Engineer-in-charge.
Supply only Spring charge motor complete all as specified and directed by Engineer-in-charge.
Supply only Closing Coil 30V DC complete all as specified and directed by Engineer-in-charge.
Supply only Tripping Coil 30V DC complete all as specified and directed by Engineer-in-charge.
Supply only Top spout with Busbar 11 KV complete all as specified and directed by Engineer-in-charge.
Supply only Bottom spout with Busbar 11KV complete all as specified and directed by Engineer-in-charge.
Supply only Power pack of voltage 24 volt DC capacity 7AH complete all as specified and directed by Engineer-in-charge.
Supply only TNC switch for open and Close complete all as specified and directed by Engineer-in-charge.
Supply only Indication lamps complete all as specified and directed by Engineer-in-charge.
Supply only Bus support insulator complete all as specified and directed by Engineer-in-charge.
S&F in repairs Current Transformer dual ratio of rating 100/50/5A, 22 KV pressure epoxy cast resin complete duly intalled, commissioned, connected and tested at site complete all as specified and directed by Engineer-in-charge.
Supply and fix in repair multifunction meter with digital display suitabale for measuring 11 KV electrical parameters( Voltage, Amp, power factor, frequcncy. Kwh, harmonics upto 31 level) MFM 4410 LCD meter Accuracy level 0.5S with RS485 complete all as specified and directed by Engineer-in-charge.
Supply and fix in replacement of Current transformer (CT) ratio 200/100/5-5A, 50 Hz, 15 VA, accuracy class-I & 5P-10 , short ckt time 18.4 KA for 1 sec, as per IS-2705 epoxy type suitable for 11 KV, VCB breaker including all necessary fixing arrangements and proper control wiring and connections complete all as specified and directed by Engineer-in-Charge
Material & labour for Repair,Maintenance of 11KV HT Potential Transformer complete including the following (a) Checking the serviceability of each PT unit of any capacity.(b) Replacement of defective parts i.e fuse of any capacity,connection wire etc and blowing out dust and applying the proper lubrication/ greasing with AP-3 grease including connection to HT panel and make the PT functional to the entire satisfaction of Engineer-in-charge. .
Supply and fixing battery charger suitable for normal and boost charge suitable for 24 volts DC complete all as specified and directed by Engr-in-charge.
Supply Only 11KV Vaccum interrupter bottle 800/630 Amps rating suitable for existing setup complete all as specified and directed by Engr-in charge
Supply and laying synthetic rubber insulated mats 3mm thick for voltage upto 66KV for electrical purpose as per IS 15652-2006 suitable for electrical shock safty of size 2m x1m complete all as specified and directed by Engineer-in-Charge.
Supply and laying synthetic rubber insulated mats 2.5mm thick for voltage upto 11KV for electrical purpose as per IS 15652-2006 suitable foe electrical shock safty of size 2m x1m complete all as specified and directed by Engineer-in-Charge.
Dismantling & taking down old, deteriorated, lightening, arrestor and supply, fixing & testing litghtening arrestor (Station type ) out door type discharge current 10 KA assembly suitable for 12 KV including all clamps ,nuts, bolts, washers, GI pipe required for protection upto 3 mtr and connection to earth with 32 x 6 mm GI strip and including expulsion type complete with all fittings transmission class discharge capacity 65 Kilo Amp suitable for 11000 Voltrs complete all as specified and directed.
M &L for replacement of 11KV jumpers by Weasel conductor at pole by new one, with PG clamp including nuts and bolts / connector for fixing / tightening two conductor of equal or unequal size as directed by Engr-in charge.
S & F in replacement of Brown Pin Insulator Color Brown Frequency 50 Hz Surface Finish Polished Working Voltage 11 KV Creepage Distance Minimum 230 mm Make:ISI approved ,size as per site requirement complete all as specified and directed by Engineer in charge
Excavation in trenches in any type of soil not exceeding 1.5 mtr wide and not exceeding 1.5 mtr in depth for taking out of unserviceble /laying under ground cable complete all as directed.
Returning filling in, approved soft/loosesoil, including spreading , levelling, watering and well ramming in layers each not exceeding 25cm in soft/loose soil complete all as specified and directed by Engineer-in-Charge.
Removal of surplus excavated soil to a distance not exceeding 50metre and depositing where directed at level not exceeding 1.5metre above the starting point complete all as specified and directed by Engineer-in-Charge.
Supply and laying double wall corrugated pipe (DWCP) of inner/outer dia 120/103 for HT cable upto size 150 Sqmm, Non-metallic, resistance to compression : type 450, resistance to impact; normal, resistance to bending: pliable, resistance to external influence; ingress protection: IP 67, resistance against corrosion: without protection, resistance to flame propagation: non flame propagating, conforming to IS-16205 (part-24), IS-14930 Part (I & II) including necessary jointing material i.e snap fit coupler with rubber ring, sealing plug, tees, bend, angel bend etc for passing electrical cable complete all as specified and directed by Engr - in charge
Material & labour for making the hole under road and hard standing suitable for laying and inserting pipe upto 100 mm dia any length by mechanical drill system or Auger system and making the surface good as existing surface complete all as specified and directed by Engineer-in-Charge.
Material and labour for cable route/path indicators made out of precast PCC duly engraved MES HT cable having PCC Pillar of size 900 mm x 300 mm x 100 mm, embedded 450 mm below groung level and 450 mm above ground level incl red colour of snowcem paint above ground level complete excavation and earth work , all as specified & directed at site.
S & F in replacement GI tubing, light grade, 100mm bore complete with all fittings for cable and earth continuity strip protection laid in trenches/fixed to poles/along wall/under road/across the drain complete all as specified and directed by Engineer-in-Charge.
S&F in replacement 1100 VA inverter pure sine wave with 12V battery 180 AH capacity and trolley for battery all as specified and directed.
Cleaning and preparation of old painted surface of steel tubular pole 11 mtr long (4/2 pole structure) excluding planting depth complete and painting with one coat of aluminium paint including brackets, clamps, channel etc. and including making alternative black and white strips on pole with synthetic enamel paint and writing pole Nos and including applying one coat of cement base paint on exposed surface of PCC coping and foundation block complete all as specified and directed by Engineer-in-Charge.
All as per srl item No. 82 here-in-before but (Single pole) complete all as specified and directed by Engineer-in-Charge.
Checking ,testing and locating HT 11KV cable fault locating by using high POT fault finding Machine vehicle mounting on rent/ manually by excavation complete with route finder mobile equipment as finding out one fault on one cable route including cutting of road/ plinth/hard standing all as specified & directed by Engr-in-Charge . Note; (1) Cutting of road/ plinth/ hard standing shall be included rates qouted by contractor NO extra will paid. (2) Excavation and cable joints shall be mesured and paid separately. (3) Required T&P shall be arranged by the contractor, The rates deemed included in qouote rates.
Surface cleaning/site clearance n exc 15 cm in depth in Sub stations area, trenches,sub station rooms, two pole/ four pole structure surroundings to make a over all presentable condition all as directed by Eng In charge.
.Supply and lay graded stone aggregate of size 40mm grade layed on ground of yard/ two/four pole structure complete all as specified and directed.
Material and Labour in replacement Cross arms, bracings, supports, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed and inclusive of one primer coat, one under coat and one finishing coat of paint complete all as specified and directed Note : The rate of one primer coat, one under coat and one finishing coat of paint is included in this item..
M&L for aluminium conductor, steel reinforced (ACSR) conductor of any size/type on HT pole with suitable T & P required complete all as specified and directed.
M&L for Painting of Electric Supply 66KV yard installation according to MES colour coding such as pole, structures,angle, GO DO etc at Swicthyard complete all as specified and directed by Engineer -in- Charge.
M&L in replacement danger notice plate of 1.6 mm thick mild steel sheet vitreous enamelled white, with letters figures and conventional skull and bones in signal red colour and fixed with MS clamps bolts and nuts of approved size for HT 11 KV of size 25 x 20 cm complete all as specified and directed.
M&L in replacement of existing U/S earthing complete with galvanised steel earth plate electrode 60 cm x 60 cm x 6 mm thick burried directly in ground vertically to a depth not less than 2.25 metre below ground level with top edge of earth plate at a depth not less than 1.5 metre below ground level, earth plate surrounded by 15cm thick packed layer of charcoal dust and common salt, connected to galvanized iron strip 32mm x 6mm thick as earth lead by means of bolts, nuts and washers of galvanised iron or steel and thimbles and other end of the earth strip connected to earthing test point/equipment and protected by galvanised iron pipe light grade 40mm dia upto earthing test point/equipment fixed with 2 Nos of mild steel clamp made out 25mm x 3mm flat iron and perforated water pipe 20mm dia GI medium grade and top with socket & plug and bottom connected to earth plate by slit and two bolts/nuts/washers, PCC chamber in cement concrete (1:2:4) type B-1 and CI cover with frame 40 x 40 x 6mm on top and excavation/ earth work complete all as shown in electrical plate No. 3 of MES Schedule Part-I of SSR-2009. Note:- (i) Outer edge of earth pit shall be 1 metre away from the outer edge of PCC chamber. (ii) GI strip upto earth test point/equipment is included in this item. (iii) Water pipe upto earth pit shall be provided in slantling position as included in this item.
Supply & spray for Anti Track coating compound spray - 320, brick Red colour all as specified and directed by Engineer-in-Charge Make: MOSIL Lubricants or equivalent
M&L for flash over carbon cleaning kit consisting of CRCA Super Gasket Remover-400ML, CRC LECTRA CLEAN-400 MLs for cleaning of carbon deposited due to flash over on bus bars and insulators complete all as specified and directed by Engineer-in-Charge
M&L for moisture removing cum protection Kit consisting of CRC-2-26-500ML , LECTRA CLEAN-400 ML complete all as specified and directed by Engineer-in-Charge
M&L for HT self fusing insulation tapes (without compound) of size 38 x 0.76 mm, 5 m long for VCB Bus bar insulation complete including taking down old to disposal off all as specified and directed by Engineer-in-Charge
Supply and fixing space heater suitable for 11KV VCB panel 80 watt complete all as specified and directed by Engineer-in-charge.
Supply & Fixing Segment gear for 11 KV Mechanism Assembly , as per size complete taking down old unsv all as specified and directed by Engineer-in-Charge
Supply and fixing PG Clamp of any size suitable for HT connection complete all as specified and directed by Engr-in-charge.
Shifting of transformer upto 500 KVA, Capasitor bank 11 KV line, dismantling of transformer foundation, steel structure at 66 KV MRS and re installation of transformer, making of new foundation/plinth as per existing transformer capacity , capasitor bank with steel structure at another location near 66 KV MRS as directed and specified by Engr in Charge.
M&L for servicing, calibration, testing and setting of fault tripping relays as mentioned in maintance and operation manual of 66 KV SF6 breaker as per OEM instructions complete as specified and directed by Engr-in-Charge.
S & F in replacement of copper bus bar for HT 11 KV VCB as per required thickness, width and length , size and mould dimension will be as per site requirement complete all as specified and directed by Engineer in charge
Singla Electricals (BID ID -3486848)
Surindera Kumar Bansal (BID ID -3486873)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.30 MB
Tender_79.pdf
Tender Documents • 0.95 MB
BOQ_826659.xls
BOQ • 0.32 MB
Download all tender documents and submit your bid