Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | I₹3.8 LAccepted-AOC 86 NAROTTAM KUNJ MADHU NAGAR AGRA UTTAR PRADESH 282001 | AGRA | UTTAR PRADESH | 282001 | I | Accepted-AOC L1 | |
| 2 | II₹3.8 LRejected-Finance 00 BEHIND CHARCH NAYAGOWAN LAKHERA BEHIND RAMA MANI DAIRY KATNI MADHYA PRADESH 483501 | KATNI | MADHYA PRADESH | 483501 | II | Rejected-Finance Refer itemwise comparative statement | |
| 3 | III₹3.8 LRejected-Finance | III | Rejected-Finance Refer itemwise comparative statement | |
| 4 | IV₹3.8 LRejected-Finance | IV | Rejected-Finance Refer itemwise comparative statement | |
| 5 | V₹3.9 LRejected-Finance GALI NO 2 H NO 45 2ND FLOOR NANAK VIHAR COLONY LAL KUAN GHAZIABAD UTTAR PRADESH 201009 | GHAZIABAD | GHAZIABAD | UTTAR PRADESH | 201009 | V | Rejected-Finance Refer itemwise comparative statement |
Tender Value
Refer Docs
Closing Date
23 Nov 2020, 9:00 amClosed
GE (WEST) AGRA
GE (WEST) AGRA
Job work for provn of 05 x window AC 2 Ton with stabilizer 5 KVA for Ortho Ward i.e Hot and Cold and MI Room of MH Agra
2020_MES_394680_1
3340/Q/10/E3/2020-21
Limited
Miscellaneous Works
Works
30 days
GE (WEST) AGRA
Please refer Tender documents.
2 documents required · 2 mandatory
₹0
Exempted
8 Dec 2020
12 Nov 2020
24 Nov 2020
12 Nov 2020
23 Nov 2020
17 Nov 2020
Amount
The following job work for provision of 05 x window AC 2 Ton with stabilizer 5 KVA for Ortho ward(Hot & Cold) & MI Room of MH Agra are as under:- (a) Supply and install, testing & commissioning window type air conditioner of capacity 2 TR complete, single phase, 50Hz, 230 Volts, compressor high EER rotary, remote operated and R-22 refrigrent gas with minimum 2 star rating including making provision for packup of exposed portion of existing window/opening with 6mm thick plywood complete all as specified and directed. Make : Voltas/Daikin/Sumsung/Carrier/Hitachi. (b) Supply and install, testing & commissioning window type with hot and cold system air conditioner of capacity 2 TR complete, single phase, 50Hz, 230 Volts, compressor high EER rotary, remote operated and R-22 refrigrent gas with minimum 2 star rating including making provision for packup of exposed portion of existing window/opening with 6mm thick plywood complete all as specified and directed. Make : Voltas/Daikin/Sumsung/Carrier/Hitachi. (c) M&L for sub main wiring with two runs of single core FRLS PVC insulated, unsheathed, mutistranded copper conductor cable of size 4.0sqmm drawn in and including rigid PVC, rigid conduit medium grade not less than 20mm dia with its accessories, concealed type, including one run of single core FRLS PVC insulated, unsheathed, stranded copper conductor cable of size 2.5 Sqmm as earth continuity and cutting chases as per standard engineering practice & making good the disturbed surfaces as per existing complete all as specified and directed. Note:(i) Finished sub main wiring with two run of 4.0 sqmm cable & one run of 2.5 sqmm cable alongwith PVC conduit inluding its accessories shall be measured and paid one unit length. (ii) Connection of cables with MCBs or bus bars shall be done through appropriate size brass/copper thimbles. (d) Supply and fix voltage stabilizer with built in high cut, buzzer & timer for automatic operation single phase naturally air cooled indoor type & designed for input variation between 140V to 280 with output voltage at 230V with accuracy of (+- 1.0%), 47 Hz to 53 Hz of capacity 5.0KVA complete all as specified and directed. Make V-Gaurd/Blue Bird/Kirnotic. (e) S&F sheet metal enclosure with two pin and earth plug and socket complete with one pole MCB 20amps, SP, 230 volt 10 KA 'C' series for AC complete all as specified & directed. Make HPL/Legrand/Havells. (f) Supply and fix MCB DB sheet metal enclosure factory fabricated double door TPN 4 way with 200 amps rated bus br 240 volts complete all as specified and directed. Make HPL/Legrand/Havells. (g) S&F MCB SP 6 to 32Amps 240 volts, C series, 10KA complete all as specified and directed. Make HPL /Legrand/Havells. (h) Supply and laying or fixing or passing through pipe, 1100 volts grade heavy duty cable with PVC insulated stranded aluminium conductor served with an inner sheathing of PVC tape armoured with galvanised steel wire or tape and overall PVC sheathed 4 core 16 sqmm nominal cross section in service connection complete all as specified and directed. Make of cable : Finolex/Plaza/Polycab/Anchor. (j) Excavation in trenches, in soft/loose soil n. exc 1.5m wide and n.exc 1.5m depth, for fdn etc or for shafts wells cespits, manholes pier holes etc, n.nex 10 sqm on plan and getting out complete all as specified and directed. (k) Returning filling including spreading, levelling,watering and well ramming in layers n exc 25cm thick complete all as specified and directed. (l) Removal of excavated material not exc. 100 mtr and deposited where directed at a level not exc.1.5mtr above the strating point complete all as specified and directed. (m) Material and labour for 40mmm dia bore pipe galvanised steel tubing light grade for protection of cable/earth continuity conductor fixed to poles/walls/roof or laid infloors, road crossing/in ducts fixed with two clamps 2 Nos FI of 40x6 mmm size with nuts bolts and washer etc complete all as specified and directed. (n) M&L sub class 'B' old size bricks laid adjacent to each other perpendicular to the direction of cable in trenches for protection of cable complete all as specified and directed. (o) M&L for providing dry river sand as in sand cushioning to underground PVC cable including punning down of sand in layer all as specified and as directed. Note : Punned thickness of sand shall be measures for payment.
3Krishna Enterprises
M/s Tirupati Enterprises
VAKRATUNDA CONSTRUCTION CO
M/s A K Engineering Co
Shiva Enterprises
stage.html
html • 0.05 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_440436.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .