Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹12.7 LAccepted-AOC | ₹12.7 L Quoted ₹15.7 L | L1 | Accepted-AOC Lowest Bidder |
| 2 | L2₹16.2 L+₹55,340 (3.53%)Rejected-Finance HOUSE NO 415 ALIKAN ROAD MANDI DABWALI SIRSA HARYANA 125104 | MANDI DABWALI | SIRSA | HARYANA | 125104 | ₹16.2 L+₹55,340 (3.53%) | L2 | Rejected-Finance High Rate Quoted |
| 3 | L3₹16.7 L+₹1.0 L (6.58%)Rejected-Finance | ₹16.7 L+₹1.0 L (6.58%) | L3 | Rejected-Finance High Rate Quoted |
| 4 | L4₹16.8 L+₹1.1 L (7.28%)Rejected-Finance | ₹16.8 L+₹1.1 L (7.28%) | L4 | Rejected-Finance High Rate Quoted |
| 5 | L5₹18.0 L+₹2.3 L (14.7%)Rejected-Finance C O SHRI AMRENDER KUMAR YADAV IACHHIPUR SANTOSH NAGAR GORAKHNATH GORAKHPUR UTTAR PRADESH PIN 273015 | GORAKHPUR | UTTAR PRADESH | 273015 | ₹18.0 L+₹2.3 L (14.7%) | L5 | Rejected-Finance High Rate Quoted |
Tender Value
₹25 L
EMD Value
₹50,000
Closing Date
1 Apr 2024, 6:00 pmClosed
Col Shery Goel, CWE Bikaner
HQ CWE Bikaner, Bikaner Mil Stn
Repair and maintenance of ceiling fan, exhaust fan, wall mounting fan and connected items under GE (A) Suratgarh
2024_MES_645057_1
CA No CWE BKN-Token No. 109/2023-2024
Open Tender
Civil Works
Item Rate
180 days
GE N BIKANER
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
Yes
GE (N) Bikaner
₹50,000
Yes
8 May 2024
4 Mar 2024
8 Apr 2024
4 Mar 2024
1 Apr 2024
18 Mar 2024
4 Mar 2024 - 9 Mar 2024
Amount
Taking down existing Ceiling fan & Exhaust Fan of any make and size from fan hook, opening / dismantling fan for repair / replacement of unserviceable parts such as ball bearings, bushes, rotor, stator & rewinding of fan motor, capacitor including tightening bolts, nuts, screws, loose connections and re-assembling after necessary repair / replacement of unserviceable parts & greasing, oiling, making fully functional to the entire satisfication of Engineer-in-Charge and hanging in same position including testing for required speed and air displacement and complete all as specified and directed by Engineer-in-Charge. Note : If the contractor fail to rectify the defects/complaint (repair of ceiling fan, winding and servicing) within 72 hours. He will be charged Rs. 150/- per complaint per day and same shall be recovered from his RAR. The contractor has to setup repair workshop (winding and servicing) of ceiling fans inside in Mil contonment area.
M&L for cutting and removing the old defective/burnt winding of ceiling fan 1200mm sweep, cleaning the core of the fan motor, rewinding the motor with super enamelled copper winding wire of suitable turn and gauge as per the original including replacement of insulating material and using varnish class ‘B’ for insulation complete all as specified and directed. Make for winding wire : Devidyal / Chetak/ Atlas/ Milan Note :- Cost of copper winding wire and all insulating materials are included in the unit rates of these items and nothing extra shall be paid on this account.
M&L for cutting and removing the old defective/burnt winding of ceiling fan 1400mm sweep, cleaning the core of the fan motor, rewinding the motor with super enamelled copper winding wire of suitable turn and gauge as per the original including replacement of insulating material and using varnish class ‘B’ for insulation complete all as specified and directed. Make for winding wire : Devidyal / Chetak/ Atlas/ Milan Note :- Cost of copper winding wire and all insulating materials are included in the unit rates of these items and nothing extra shall be paid on this account.
M&L for cutting and removing the old defective/burnt winding of exhaust fan 230mm sweep, cleaning the core of the fan motor, rewinding the motor with super enamelled copper winding wire of suitable turn and gauge as per the original including replacement of insulating material and using varnish class ‘B’ for insulation complete all as specified and directed. Make for winding wire : Devidyal / Chetak/ Atlas/ Milan Note :- Cost of copper winding wire and all insulating materials are included in the unit rates of these items and nothing extra shall be paid on this account.
M&L for cutting and removing the old defective/burnt winding of exhaust fan 300mm/ 380mm/ 600mm sweep, cleaning the core of the fan motor, rewinding the motor with super enamelled copper winding wire of suitable turn and gauge as per the original including replacement of insulating material and using varnish class ‘B’ for insulation complete all as specified and directed. Make for winding wire : Devidyal / Chetak/ Atlas/ Milan Note :- Cost of copper winding wire and all insulating materials are included in the unit rates of these items and nothing extra shall be paid on this account.
M&L for cutting and removing the old defective/burnt winding of pedestal fan 230mm sweep, cleaning the core of the fan motor, rewinding the motor with super enamelled copper winding wire of suitable turn and gauge as per the original including replacement of insulating material and using varnish class ‘B’ for insulation complete all as specified and directed. Make for winding wire : Devidyal / Chetak/ Atlas/ Milan Note :- Cost of copper winding wire and all insulating materials are included in the unit rates of these items and nothing extra shall be paid on this account.
M&L for cutting and removing the old defective/burnt winding of cabin fan/ wall fan 400mm/ 450mm sweep, cleaning the core of the fan motor, rewinding the motor with super enamelled copper winding wire of suitable turn and gauge as per the original including replacement of insulating material and using varnish class ‘B’ for insulation complete all as specified and directed. Make for winding wire : Devidyal / Chetak/ Atlas/ Milan Note :- Cost of copper winding wire and all insulating materials are included in the unit rates of these items and nothing extra shall be paid on this account.
Supply only ball bearing of required size for ceiling fan of size 1200/1400mm sweep ISI marked complete all as specefied and as directed. (Make: NBC/SKF)
Supply only Gun metal bush of existing / required pattern for ceiling fan of size 1200mm /1400mm sweep complete all as specefied and as directed.
Supply only hanging rod for ceiling fan made out of 600mm long, 15mm dia GI pipe medium grade with two coat of synthetic enamel paint including threading / cutting at both ends with hole and check nuts, bolts, screw etc complete all as specified and directed.
Supply only hanging rod for ceiling fan made out of 450mm long, 20mm dia GI pipe medium grade with two coat of synthetic enamel paint including threading / cutting at both ends with hole and check nuts, bolts, screw etc complete all as specified and directed.
Supply only mild steel clamp assembly including steel nut bolt, split pin heavy duty suitable for ceiling fan of any make and size complete all as specified and directed.
Supply only capacitor of 2.5 mfd capacity, 230 Volts including provision of insulation sleeves ISI marked complete all as specified and directed
Supply only capacitor of 3.15 mfd capacity, 230 Volts including provision of insulation sleeves ISI marked complete all as specified and directed
Supply only capacitor of 4.0 mfd capacity, 230 Volts including provision of insulation sleeves ISI marked complete all as specified and directed
Supply only connection lead consisting of PVC unsheathed, PVC insulated twin core flexible copper wire of size 23/ 0.0076 for making the connection from ceiling rose to ceiling fan/ exhaust fan complete all as specified and directed
Supply only armature of ceiling fan duly winding complete with shaft of existing make and size complete all as specified and directed
Supply only Mild Steel split pin of required size of ceiling fans complete all as specified and directed.
Supply only Mild Steel nut bolt, 50mm long, 8mm dia for ceiling fans complete all as specified and directed
Supply only Mild Steel screw bolt for fixing of ceiling fans complete all as specified and directed
Supply only capacitor clamp made of PVC of appropriate size and fixing screw complete all as specified and directed.
Supply only rubber real suitable for 3/8" bolt complete all as specified and directed.
Supply only PVC Canopies (upper & lower) suitable for ceiling fan of any size as required at site complete all as specefied and as directed.
Supply only metallic fan blade set suitable for ceiling fan of size 1200mm sweep of any make / model and of existing pattern and gauge duly painted as per sample complete all as specified and directed.
Supply only metallic fan blade set suitable for ceiling fan of size 1400mm sweep of any make / model and of existing pattern and gauge duly painted as per sample complete all as specified and directed.
M&L for painting to Ceiling Fan & Exhaust Fan of any sweep/ any size/make, checking nut bolts and replace if required, painting the fans (at store yard of AGE E/M or as per direction of Engineer-in-charge) complete including fan body, blades, canopies etc. with synthetic enamel white/ Black/ Grey paint by spray gun after cleaning all dust / spoil and greasy spots and including using filler for filling cavities. After painting MES No shall be marked with red colour synthetic enamel paint using stencil as per existing number complete all as specified and directed.
Supply only bottom cover of ceiling fan complete with bearing holder for the existing make and colour of ceiling fan as required at site including two coat of synthetic enamel paint complete all as specified and directed.
Supply only top cover of ceiling fan complete with bearing holder for the existing make and colour of ceiling fan as required at site including two coat of synthetic enamel paint complete all as specified and directed.
Supply only magnetic ring of ceiling fan of existing make as required at site complete all as specified and directed.
S&F in replacement electronic fan regulator suitable for ceiling fan of size 1200mm/1400mm sweep, socket size, step type complete all as specified and directed.
S&F in replacement ball bearing of required size for exhaust fan of size 300 / 380mm Sweep ISI marked complete all as specified and directed.
S&F in replacement ball bearing of required size for Cabin/ Wall fan of size 400mm Sweep ISI marked complete all as specified and directed.
S&F in replacement ball bearing of required size for pedestal fan of size 450mm Sweep ISI marked complete all as specified and directed.
S&F in replacement fan blade set suitable for exhaust fan of 300mm sweep of any make / model as per sample or as complete all as specified and directed.
S&F in replacement fan blade set suitable for exhaust fan of size 380mm sweep of any make / model as per sample or as complete all as specified and directed.
S&F in replacement fan blade set suitable for exhaust fan of size 350mm sweep of any make / model as per sample or as complete all as specified and directed.
S&F in replacement fan blade set suitable for exhaust fan of size 400mm sweep of any make / model as per sample or as complete all as specified and directed.
S&F in replacement fan blade set suitable for exhaust fan of size 450mm sweep of any make / model as per sample or as complete all as specified and directed.
S&F in replacement Gun metal bush of existing / required pattern for pedestal fan of size 450mm sweep complete all as specified and directed.
S&F in replacement PVC insulated flexible copper wire 2.5sqmm 3 core size complete all as specified and directed.
S&F in replacement base plate for ball bearing suitable for ceiling fans of size 1200mm/ 1400mm sweep complete all as specified and directed.
S&F in replacement motor for exhaust fan of size 450mm sweep as per existing make / size complete all as specified and directed.
S&F in replacement motor for exhaust fan of size 380mm sweep as per existing make / size complete all as specified and directed
S&F in replacement motor for exhaust fan of size 300mm sweep as per existing make / size complete all as specified and directed.
S&F in replacement motor for plastic type exhaust fan of size 250mm to 350mm sweep as per existing make / size complete all as specified and directed.
S&F in replacement fan blade suitable for plastic type exhaust fan of size 250mm sweep as per existing make / size complete all as specified and directed.
S&F in replacement outer body of plastic type exhaust fan of size 250mm to 350mm sweep as per existing make / size complete all as specified and directed.
SIGMA ENGINEERS AND CONTRACTORS
MAJOR REFREGERATION AND ELECTRICALS
Bhavya Enterprises
SHIVA BUILDERS
JK ENGINEERS
S.K BUILDERS AND ENGINEERS
DASHMESH ENTERPRISES
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .