Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹14.8 LAccepted-AOC HOSUE NO 202 NEW RAM VIHAR COLONY PINTO PARK MORAR GWALIOR 474005 MP | GWALIOR | MADHYA PRADESH | 474005 | L1 | Accepted-AOC BEING LOWEST TENDER | |
| 2 | L2₹14.9 L+₹9,305 (0.63%)Rejected-Finance 84 A VIJAY NAGAR COLONY LALGHATI PO NAYAPURA BHOPAL 462032 | 462032 | L2 | Rejected-Finance Not being lowest tender | |
| 3 | L3₹15.2 L+₹45,396 (3.08%)Rejected-Finance | L3 | Rejected-Finance Not being lowest tender | |
| 4 | L4₹16.5 L+₹1.8 L (12.0%)Rejected-Finance 1A BASEMENT 30 31 RAJA HOUSE NEHERU PLACE NEW DELHI | NEW DELHI | NEW DELHI | DELHI | L4 | Rejected-Finance Not being lowest tender | |
| 5 | L5₹18.0 L+₹3.2 L (21.9%)Rejected-Finance 01 TIWARI BAZAAR GONDA ROAD TIWARI BAZAAR GONDA UTTAR PRADESH 271001 | GONDA | UTTAR PRADESH | 271001 | L5 | Rejected-Finance Not being lowest tender |
Tender Value
₹16.6 L
EMD Value
₹33,200
Closing Date
19 Oct 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE AF TA
GE AF TA GWALIOR-474020
PROVN OF STANDBY POWER SUPPLY AT WSA AT AF STATION GWALIOR
2022_MES_553342_1
8900/1432/GWL/E8
Open Tender
Electrical and Maintenance Works
Item Rate
240 days
GE AF TA GWALIOR
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
GE AF TA GWALIOR
₹33,200
Yes
24 Nov 2022
21 Sept 2022
27 Oct 2022
21 Sept 2022
19 Oct 2022
5 Oct 2022
21 Sept 2022 - 4 Oct 2022
Amount
Supply, commissioning, erecting and testing complete static silent (Sound Proof enclosure) Diesel Engine Driven Generating Set of capacity 100 KVA or next higher capacity, water cooled, 415 Volts (AC three phase, 4 Wire system of supply) 50 Hz at power factor 0.8 minimum. The DG Set shall consists of diesel engine coupled to a matching alternator, through flexible coupling and mounted on common base frame and complete with control panel standardized by manufacturer, fuel tank with mounting arrangements and inlet, outlet return inlet oil arrangement, exhaust pipe complete and suitable for conditions prevalent at Gwalior including PCC foundation (of suitable size leaving at least 0.5m all around for ease of movement and 0.5 M height), anti-vibration pads complete all as specified and directed, including all features to comply with latest CPCB guidelines and comprising of followings:-
(i) ENGINE (Prime Mover): Diesel Engine 1500 RPM, direct injection, four cylinders, four stroke,DG Set GPWII-PII-100 Powered with Greaves Make :- 4 cylinder Engine model 4g 11TAG25 at 0.8 power factor at NTP Conditions 415 V 50HZ Couplied with 3 phase Crompton Greaves Alternator mounted on common base frame along with outdoor AMF pads and other standard with cable (12V/88 AH ) Fule Tank capacity 350 Ltr ,AVM Pads and other standard accessories as ,ENGINE OUTPUT :126.53 Radiator cooled. confirming to IS:10000/ISO3046/BS:649/BS:5514 amended up to date, for continuous running capable of taking 10% overload for one hour in 12 Hour, water cooled, naturally turbo charged having adequate BHP to drive alternator 100 KVA or next higher capacity at outdoor atmostpheric conditions at Gwalior fitted with the following accessories subject to the design of manufacturer:
(a) Dynamically balanced fly wheel with starter ring (b) Air cleaned oil bath type. (c) Electronic/ Digital governer Class 1A. (d) Dry exhaust manifold with suitable exhaust residential grade silencer to reduce the noice level. (e) Radiator cooling. (f) Radiator fan with guard. (g)Vaccum indicator. (h) Fuel filter and fuel hoses. (j) Fuel injection pump (FIP) (k) Fan and water pump assembly. (l) Lubricating oil filter and pump. (m) Electrical starting system with battery charging alternator and axial type starter motor including adquate number of high capacity maintenance free lead acid battery, 12 Volts DC as per manufacturer recommendation including interconnecting cable/ leads with terminal complete with start/ stop switch. (n) Engine safety shut down system against low oil pressure and high water pressure. (o) Exhaust gas driven turbo charger. (p) Oil filter. (q) Lube oil cooler. (r) Engine maintenance manual with spare parts list. (s) Suitably designed acoustic enclosure as per CPCB regulation. (t) Any other item not included/ specified but is a standard design of the manufacturer.
(ii) ENGINE INSTRUMENT ELECTRONIC PANEL:- Engine instrument panel shall comprising of the following control : (a) Starting on/ off switch. (b) Water tempreture display. (c) Hour meter cum RPM display. (d) Lub oil pressure display. (e) Lub oil tempreture display. (f) Battery charging display. (g) Safety alarm against high water tempreture and low oil pressure. (h) Automatic on/off of engine facility with GCU (j) Any other item not included/ specified but is a standard design of the manufacturer.
(iii) ALTERNATOR:- Alternator shall be self excited, self regulated, brushless for 100 KVA or next higher capacity continuous operation at the speed of 1500 RPM at 415 Volts, 50 Hz, Three Phase, 4 Wire system with advance electronic voltage regulator to ensure high voltage accuracy with +1% with class H insulation and SPDP enclosure directly coupled with engine through flexible coupling and confirming to IS-4722 complete-01 No Note:- Alternator should be able to deliver output rating at actual site conditions.
(iv) Common fabricated base frame for engine and alternator made from structural channel leak proof PCC 1:2:4 mix, type B1 foundation including adequate number of suitable anti vibration pad all as per the recommendation of the manufacturer-01 Number (v) Bottom mounted (or as per manufacturer design) steel fuel tank fabricated out of 14 SWG MS sheet of capacity not less than 16 Hour continous operation inside canopy with fuel level gauge, drain plug, locking arrangement etc with and including GI pipe connection duly laid as per Engineering practice complete.
(m) Set of relays and contactor with 2 NOs MCCB 4 Pole, 200 Amps, 25 KA DPX model of Legrand or equivalent as specified for automatic start and automatic shutdown of DG Set. (n) Internal connections with copper cable of adequate size from control panel/ DG Set of AMF Panel. (o) KWH meter. (p) Hours run meter.
(vii) Bypass arrengement by providing separate panel integrated in AMF panel made out of 14 Gauge CRCA sheet, outdoor type with connecting copper bus bar of suitable size from change over and set of Nos indication lamp for R, Y and B and 2 Nos 4 pole on load change over switch front handle operated of capacity 200 Amp is to be installed near AMF panel complete all as specified and directed . (viii) Indicating lamp for battery charging . (ix) Any other item not included /specified but is a standard design of the manufacturer . Note - 1.AMF panel and bypass panel shall be installed outside the acoustic enclosure and any civil work required shall be included in quoted rate . as directed by Engineer-in charge . 2 . The plateform for erection / installation of DG set shall be as per manufacturer instructions . 3 .The Design of AMF panel shall be approved by Accepting Officer prior to placing order .
Supplying & fixing MCCB 4 POLE 250 Amps (in existing panel ) with ruturning capacity 35/36 KA complete with enclosure all as specified and directed .
Supplying & fixing MCCB 4 Pole 160 Amps with rupturing capacity 50 KA complete with enclosure all as specified and directed .
Supplying, laying and testing cable XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cable (heavy duty) 1100 Volts grade with standard aluminium conductor of size 120 sqmm 3.5 core complete all as specified and directed.
Supplying, laying and testing cable XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cable (heavy duty) 1100 Volts grade with standard aluminium conductor of size 35 sqmm 3.5 core complete all as specified and directed.
Supply and laying cable XLPE insulated screened PVC sheathed armoured heavy duty electric cable with aluminium conductor 1100 volts grade of size 70 Sqmm 3.5 Core complete all as specified and directed.
Excavation in trenches in soft/loose soil not exceeding 1.5 m deep and not exceeding 1.5 m width and getting out including forming bottom surface for laying cables/pipes all as specified and directed.
Returning, filling in including spreading, leveling, watering and well ramming in layers n. exc 25 cm thick after the cables are laid, jointed & tested complete all as specified and directed.
Removing of surplus excavated spoil not exceeding 50 M distance and depositing where directed at a level not exceeding 1.5 m above the starting point complete all as specified.
Material & labour for sand filling with clean dry find sand unwashed including gently punning around cables in trenches for cable protection complete all as specified and directed.
Supplying & Laying PCC cable covers , unreinforced, ISI marked, Type -2 ,class LV , flat size 300 mm X 150 mm X40 mm size all as specified and directed.
Supply & fix ON LOAD change over switch 415 volts in sheet metel enclosure 4 ploe of capacity 100 Amps complete all as specified and directed.
M&L Earthing with galvanized steel earth plate electrode 600 mm x 600 mm x 6 mm thick, buried directly in ground (earth pit not less than 2.25 m below normal ground level) with top edge of earth platenot less than 1.5 m below normal ground level connected to galvanized earth lead to GI strip 32 x 6 mm, by means of bolts, nuts, check nuts and washers of brass connected all as shown in the electrical plate No 1 of MES schedule Pt-I 2009, including necessary earth work and PCC 1:2:4 type B2 pit including charcoal & common salt in alternate layers of 150 mm thick, Gi pipe 20 mm dia light grade watering pipe with PGI funnel with wire mesh, cover 40 mm thick in RCC 1:2:4 with 8 mm dia TMT bar @ 75 mm centre to centre both ways, lifting handel 2 Nos of 12 mm dia MS round bar on both sides fixed in MS angle iron frame 40x40x5 mm and GI strip 32x 6mm from earth plate to test point upto 7.5m including 40mm dia protection pipe wherever buried under ground including testing point of Phosphorous bronze/gun metal of size 75x75x25 mm and connected to earthing test point including testing on completion complete all as specified and directed. Note:- The value of earth resistance at test point shall not be more than 5.0 ohms. If ER value is greater that 5.0 ohms, the contractor shall provide additional earthings and interconnect to bring the ER value within acceptable limit without any addtional cost.
POONAM ELECTRIC INDUSTRY
M/S Amit Traders
MONA GENERATOR SEVICES PVT. LTD.
M/s A.K. Trading Co.
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .