Loading…
Loading…
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance | Admitted-Finance |
| 2 | Admitted-Finance | Admitted-Finance |
| 3 | Admitted-Finance | Admitted-Finance |
| 4 | Admitted-Finance 0 S F ENTERPRISES CHANDAK CHANDAK POONCH POONCH JAMMU KASHMIR 185101 UDYAM JK 14 0008974 | POONCH | JAMMU AND KASHMIR | 185101 | Admitted-Finance |
| 5 | Admitted-Finance | Admitted-Finance |
Tender Value
Refer Docs
EMD Value
₹50,000
Closing Date
8 Jun 2020, 4:00 pmClosed
Superintending Engineer Distribution Circle Leh
Superintending Engineer Distribution Circle Leh
Supply of materials for various 66/11KV sub/stations,66KV,222KV Transmission Lines ,22/11 KV Substation for STD Leh
2020_PDNRE_13_1
E NIT NO 02 of 2020
Open Tender
Electrical Goods/Equipment
Item Wise
120 days
Executive Engineer Sub Transmission Division Leh
Please refer Tender documents.
3 documents required · 3 mandatory
₹500
Executive Engineer STD Leh
₹50,000
26 Jun 2020
26 May 2020
11 Jun 2020
27 May 2020
8 Jun 2020
28 May 2020
General Spraes (As per Sample)
SF6 Breaker( out door type ) ,132 kv make seimens
Lightning Arrester discharge current 10 KA Class II for 66 KV Line
Battery Charger 30 V DC,200 AH (HBL Make or Equavalent)
line isolator 145 KV
Battery Bank 2 V 200 AH of HBL make with rack
Bus isolator 145 KV for 66KV line
ACSR Panther conductor
PG Clamps for ASCR Panther conductor (heavy duty)
T Clamp for ACSR Panther Conductor (Heavy duty)
Chemical Earthing Complete Set (Earthing Rod 3mtr. 80 mm dia,Compound Chemical for Dry soil )
132 KV CT (Insulation level 230/550 KV,HSV 132 KV) current ratio 400/200/1 ,Burden 15 VA,3 core type
132 KV PT(Insulation level 140/325 KV)Ratio (66/under root 3) KV,(110/under root 3)KV,Burden 50 VA,HSV 72.5 KV
Transformer oil for power transformer ( with test report)
11 KV XLPE Armourmed Cable terminating Kit 400 Sq.mm Indoor 3 core of 3 M make or eqvivalent
11KV XLPE Armourmed Cable terminating Kit 400 Sq.mm Outdoor 3 core of 3 M make or eqvivalent
11KV XLPE Armourmed Cable terminating Kit 240 Sq.mm Indoor 3 core of 3 M make or eqvivalent
11KV XLPE Armourmed Cable terminating Kit 240 Sq.mm Outdoor 3 core of 3 M make
11 KV XLPE Armourmed Cable terminating Kit 185 Sq.mm Indoor 3 core of 3 M makeor eqvivalent
11 KV XLPE Armourmed Cable terminating Kit 185 Sq.mm Outdoor of 3M make or eqvivalent
11KV XLPE Armourmed Cable terminating kit 120 sq.mm indoor 3 core of 3 M make or eqvivalent
11 KV XLPE Armourmed Cable terminating kit 120 sq.mm outdoor 3 core of 3 M make or equavalent
11 KV XLPE Armourmed Cable terminating kit 300 sq.mm outdoor 3 core of 3 M make or equavalent
Hot blower industrial type capacity 21 KW ,OPERATING VOLTAGE 415V/3 PH/AC//50HZ
SF6 Gas with cylinders
Multistrand wire 2.5mm of reputed make
Multistrand wire 1.5mm of reputed make
2 Core Aluminium Cable 10mm ( Armourmed )
2 Core Aluminium Cable 6mm ( Armourmed )
Flood Lights LED 100 W,100 lumin
Polymer type Disc insulators (70KN) for 33 KV
Polymer type Disc insulators (70KN) for 11 KV
Mid spain join for panther conductor
Repair sleeves for Panther Conductor
Tension fitting for Panther Conductor
CMRI with soft ware and optical port.
Auxillary transformer RATING 11KV/415 KV 63 KVA ,level ii,three phase energy efficient ,confirming to BIS standard .
Fire Extiguisher powder type 6 kg for electrical equipments.
11 kv link set 50mm x 6mm with Copper blade .
22 kv isolator copper blade with earth blade complete set with gear box.(motorised)
Aluminium tape
Gas blow lamp ( handy type ) for cable kit
LA surge counter 66KV
RJ45 Jack
11 Kv XLPE Cables 185mmsq.3 core armourmed (of reputed make )
11 KV XLPE Cables 400mmsq.3 core armourmed (of reputed make )
11 KV XLPE Cables 630 mmsq.3 core armourmed (of reputed make )
GI strip 50mm x 6 mm of hard dip galvanised
Spares for 11 KV Breaker (As per Sample)
Restricted earth fault relay ,1A,20-80%, CAG14AF14A (AREVA)
Thermostat, 30-110 deg. Expo/Saiego
Bus wire terminal,45A,660V,CSTSB4 ,Elmex/connectwell
Disconnecting terminal,45A,660V,CSTSB4 ,Elmex/connectwell
VCB Panel space heater 80 W
Earth terminal
Fuse 4A, NSD4 ,Bussmann
Fuse 2A,NSD2 ,Bussmann
Fuse 10A,NSD10,Bussmann
Green Indicating lamp ,24VDC,3SB1402-2HZ2,Siemens or eqvavalent
Clear indicating lamp,24VDC,3SB1401-2HZ2,Siemens or eqvavalent
Amber indicating lamp,24VDC,3SB1403-2HZ2,Siemens or eqvavalent
Blue indicating lamp,24VDC,3SB1401-2HZ2,Siemens or eqvavalent
Red indicating lamp,24VDC ,3SB1401-2HZ2,Siemens or eqvavalent
Panel illuminating lamp,40W,Filament type,Philips or eqvavalent
Feeder prot relay,As per MSLD,MICOMP111L,Areva or eqvavalent
4NO+4NC Auxiliary Contactor,24VDC,6A,3TH3040-OBB4+3TX4001-2A,Siemens or eqvavalent
Master trip & lock out relay,24VDC,3M1B,VAJH13YF82A,Areva or eqvavalent
2NO+2NC Auxiliary contactor,24VDC,6A,3TH3022-OBB4,Siemens or eqvavalent
Link,16A,NNSF,Bussmann or eqvavalent
Multicore terminal,45A,660V,CSTSB4,Elmex/connectwell or eqvavalent
96sqmm Ammeter, As per MSLD,Digital,AE or eqvavalent
Trivector meter,As per MSLD,E3Y,Premier,SEMS
Digital voltmeter,0-15KV,Digital,96sqmm,AE
HWX Type VCB,As per MSLD,Vaccum,Areva
Resistor
AC On-Off switch,16A,2P,SRP123,KAYCEE
DC On-Off Switch,16A,2P,RP123,KAYCEE
MCB,4P,4A,AC,LEXIC,6033 14,LEGRAND
PB(Red),22.5mm,Mushroom,STS
Motor switch,10A,2P,OFF-ON,1S260,KAYCEE
Heater switch,10A,2P,OFF-ON,1S260,KAYCEE
Toggle switch,6A,1P,KT1021BY,KAYCEE
Limit switch 1NO+1NC,6A,250V,Push rod,ESSEN
Breaker control switch,25A,Non-Lockable,BCD02P006A96,KAYCEE
Local remote switch,16A,2P2W,RP125A/TB3/LG12,KAYCEE
Blue push button,22.5MM DIA,STANDARD,STS
Limit switch 1NO-1NC c/o,15A,250VAC,1NO/NC C/O,Brisk
Plug & socket,240V,32A,3PIN,PS32BA7,BCH
Limit switch 1NO-1NC c/o,15A,250VAC,1NO/NC C/O,Brisk
Current Transformer,See scheme,Resin cast,Areva
11KV/110V Potential Transformer,100VA/PH,CL-0.5,D/O 3P3L,Audio/Kappa/Plastofab
Current Transformer,See scheme,Wound Type,Areva
Limit Switch, 1NO-1NC C/O,15A,250VAC,1NO/NC C/O,BRISK
1PH Bridge rectifier ,10A, PIV:1000V,MD5BU1010,SEMI-KRON
HT FUSE,11KV,3.15A,12ABCNA3.15,BUSSMANN
TNC SWITCH
Capacitor ,8micro frad 5%+-, 450AC, 50/60HZ ,CBB61
OC/EF Feeder Pro Relay ,REJ 601,ABB
Tripping Coil and Closing Coil for ABB Circuit Breaker ,24VDC
OC/EF Feeder Pro Relay,CGI 14N,Crompton Greaves
Tripping Coil ,24 VDC, 2.2 ohms
Closing Coil ,24 VDC, 4 ohms
Hotter 24 VDC
Anti Pumping relay for ABB VCB
MCB 6 Amp,SH201M, SH201M,
MCB 7 Amp SH202M
HRC Fuse for 11 KV VCB Panel of ratings 2/4/5/10/16/20/25 Amps as per sample
Copper Bus bar
Isolation contactors Spout Bushing as per sample
Bus bar insulation for bus bar as per sample
Insulating mat ( 1 x 2)12 mm thickness
illumination bulb for breaker
Energy meter for 11 kv breaker (abb make)as per sample
micom relay p111
11kv VCB bottles ,Compatible with existing vcb bottles (as per sample )
Auxillary contractor reraly ( as per sample )
Spares for 66 KV Breaker(As per Sample)
66kv EM relay 3 over current ,1 earth fault . Make ABB, Ashida ,Areva
86 Master trip relay make ABB ,Ashida ,Areva ,schinider
66 kv Tripping Coils Areva Make or equavalent
66 kv Closing Coils Areva Make or equavalent
66 kv energy meter
Voltmeter (as per sample )
Ammeter ( as per sample)
30VDC Hooter
T&P Items
Hydraulic Conductor Cutter (Suitable for ACSR Conductor of reputed company)
Hydraulic heavy duty crimping tool (120mm to 630 mm of reputed make)
PP Rope size 25 mm dia
Digital Phase sequence meter (Fluke Make or equavalent)
Digital Hygro meter for checking specific gravity
Earth Tester spike 4 pole digital meter.
Rubber Hand Gloves ( Heavy Duty)
Safety belt heavy duty
come along clamp for 33 KV ,66 KV
discharge rod
link rod
BDV oil testing machine( model no. OTS 100AF,-50 to +50kVrms,voltage resolution and accuracy 0.1Kv+1, 2 Digits.designed in accordance with IEC 61010.
BDV oil testing sampling bottles
THR Measurement device
DC earth fault locator (digital)
soldering kit with solder of various gauge .
Electronic welding machine along with welding rod MS & SS type
fibre hand welding screen
PPM oil testing sampling bottles
Multimeter along with clamp fluke
Tool kit (TOPTUL Make) Item Code (GCAZ0049,63 Pcs tool chest set)
Crimping tool for LAN
Hydrometer for batteries
Silica Gel
Power Transformer 6.3 MVA (As per existing Xmer)
Cu LT Bush rod for 6.3 MVA XMER
Bushes
Gasket
Breather Set
Buchholz relay
Power Transformer 10 MVA (As per existing Xmer)
Cu LT Bush rod for 10MVA XMER
Bushes
Gasket
Breather Set
Buchholz relay
Power Transformer 3.15 MVA(As per Existing Xmer)
Cu LT Bush rod for 3.15 MVA XMER
Bushes
Gasket
Breather Set
11/0.11 KV Voltage Transformer for 11 KV Panel
HRC fuse for Voltage Transformer (as per Sample)
M/s S. F. ENTERPRISES
CHHEIRPON ENTERPRISES
M/S LEH STAR LIGHT
DRUK ELECTRICALS
M/S ZARDEEP ENTERPRISES
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .