Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹17.6 LAccepted-AOC | L1 | Accepted-AOC L1 | |
| 2 | L2₹20.8 L+₹2.5 L (13.5%)Rejected-AOC | L2 | Rejected-AOC L2 | |
| 3 | L3₹21.0 L+₹2.7 L (14.8%)Rejected-AOC 37 222 BUNDU KATRA AGRA UP | AGRA | UP | L3 | Rejected-AOC L3 | |
| 4 | L4₹21.5 L+₹3.1 L (17.2%)Rejected-AOC 34 35 ASHOKA ESTATE NEAR S S PUBLIC SCHOOL SEWLA SARAI AGRA 282001 | AGRA | UTTAR PRADESH | 282001 | L4 | Rejected-AOC L4 | |
| 5 | L5₹21.8 L+₹3.5 L (19.1%)Rejected-AOC | L5 | Rejected-AOC L5 |
Tender Value
₹25 L
EMD Value
₹50,000
Closing Date
3 Jul 2023, 6:00 pmClosed
GE Bharatpur
Kanjoli line Bharatpur
Comprehensive repair maintenance of split AC, window AC, desert cooler and other summer cooling appliances at Bharatpur
2023_MES_600882_1
8248/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE Bharatpur
As per NIT
6 documents required · 6 mandatory
₹500
GE Bharatpur
₹50,000
Yes
21 Jul 2023
3 Jun 2023
5 Jul 2023
3 Jun 2023
3 Jul 2023
18 Jun 2023
5 Jun 2023 - 16 Jun 2023
Amount
Taking out and servicing of window/split type air conditioner cap- 1.5/2.0 Ton incluiding cleaning/removing all dust/mud, oil and other foreign particle with compressed air/water jet from grill, screen filter at indoor unit and condenser fin, evaporator fin at outdoor unit using detergent solution or chemical solution complete all as specified and as directed .
M&L for flushing, pressurising the system , leakage testing, vacuumization and charging with refrigerant R -410/R-22 (suitable as per requirement) after rectifying leakage in the system vaccumising and dehydration as per standard practice including testing in all respect for folowing capacity split type air conditioner complete all as specified and as directed.
1.5 Ton Capacity
2.0 Ton Capacity
S & F in replacement of following items for window/ Split AC of following capacity:
Compressor for AC Capacity- 1.5 Ton for window/split AC (as per site requirement) as per existing make of LG/Voltas/Carrier/Tecumesh
Compressor for AC Capacity- 2.0Ton for window/split AC (as per site requirement) as per existing make of LG/Voltas/Carrier/Tecumesh
Starting Capacitor 80-100 / 100-120 MFD, Make : TESLA/ Godrej or Equivalent make.
Running Capacitor 36 MFD/ 45 MFD, Make : TESLA/ or Equivalent make.
Screen filter of air conditioner of cap - 1.5 / 2.0 TR as per existing make.
Starting relay suitable for window and split type AC. Make: SRIRAM or Equivalent make.
Thermostatic switch suitable for window/split type AC 1.5/2.0 Ton capacity of existing make.
Fan motor with fan blade unit suitable for 1.5/2.0 Ton capacity window /split type air conditioner of existing make.
Condenser's fan motor with blade suitable for split type air conditioner
Electronic panel board / PCB with display of non inverted Airconditioner cap- 1.5TR/2TR .
Electronic panel board / PCB with display of inverted Airconditioner cap- 1.5TR/2TR .
Plastic water drain hose pipe, 15mm dia for spit type AC .
Remote control operating device for Window/Split type AC of 1.5/2.0 Ton of existing make with 02 Nos of pencil battery.
Pencil batteries for remote of split/window AC.
Copper tubes of size 4/8, 1/2 inch with aerofoam NBR rubber insulation tube .
Copper tubes of size 3/8,5/8, 1/4 inch with aerofoam NBR rubber insulation tube .
stand for outdoor unit of existing size complete all as specified and directed.
S & F in repair indoor unit complete of existing make and size for split AC 1.5 TR complete all as specified and directed by Engr-in-charge
S & F in repair outdoor unit complete of existing make and size for split AC 1.5 TR complete all as specified and directed. by Engr-in-charge
M&L for shifting of of any type of AC, capacity 1.5/2.0 Ton complete in & out door unit including taking out brackets, pipe line and fixing insulating pipelines including brazing of copper tubes, testing/commissioning complete incl shifting of service connection and voltage stabilizer to the new location complete all as specified and as directed.
Taking out and servicing of electric driven single phase water cooler of any cap incluiding cleaning/removing all dust/mud, oil and other foreign particle with compressed air/water jet using detergent solution or chemical solution ,leakage testing of refrigerant,storage tank leakage testing complete all as specified and directed .
M&L for painting of water coolers of Cap - 150/150 Ltrs by cleaning old deteriorated exterior surface and necessary prepartion of surface by scrapping rust, grease, dirt etc before applying two coats of synthetic enamel paint by using spray painting technique to match with existing colour at existing location complete all as specified and directed by Engr in charge.
Ditto all as per Srl Item No 8 here in above but of Water cooler capacity 80/40 Ltrs.
M & L for flushing, pressurising the system , leakage testing vacuumization and charging with refrigerant R-134a at apprporiate pressure after rectifying leakage in the system vaccumising and dehydration including testing as per standard practice at site for water cooler of cap 150/150 ltrs of Make : Bluestar/Usha/Voltas complete all as specified and directed by Engr in charge.
All as per serial item No-10 above but of Water cooler capacity 80/40 Ltrs.
S & F in replacement of following items for water cooler of any capacity:
Compressor unit for water cooler 150/150 Ltrs of existing make or any othermake as specified.
Compressor unit for water cooler 80/40Ltrs of existing make or any other make as specified.
Condenser fan motor with fan blade for water cooler of any Cap of existing make or any other make apporved by GE.
Capacitor 25/35 MFD, ISI marked.
Thermostat with knob as per existing size and make.
Relay with overload protection assembly
Magnetic rubber gasket of top cover as per existing size and make
Drain water tray of stainless steel by brazing/soldering the joints, vent pipes, outlet etc as per existing size and make
Pencil type strainer alongwith capillary tube suitable as per existing size and make.
Float valve PVC 15mm bore, heavy duty.
chromium plated brass push cock size 15 mm suitable
PVC flexible pipe size 40 mm dia with necessary clamping with jubli clips for drain water tray
PVC connection of size 15 mm dia 450mm long with PTMT nuts
Repair of storage tank leakage of water cooler of any cappacity through brazzing/welding/silicon gel filling complete all as specified and directed.
Taking out and servicing of electric driven single phase refrigerators and deep freezer, of any cap, incluiding cleaning/removing all dust/mud, oil and other foreign particle with compressed air/water jet using detergent solution or chemical solution ,leakage testing of refrigerant,freezer storage leakage testing complete all as specified and as directed .
M&L for flushing, pressurising the system , leakage testing, vacuumization and charging with refrigerant R -22/R-134a (suitable as per requirement) after rectifying leakage in the system vaccumising and dehydration as per standard practice including testing in all respect for Refrigerator/deep freezer of Cap - 170/190 Ltrs complete all as specified and as directed.
All as per serial item No. 15 here –in before but of capacity 265/280 Ltrs
All as per serial item No. 15 here –in before but of capacity 300-400 Ltrs
S & F in replacement of following items for refrigerator/deep freezer of any capacity:
Compressor unit for Refrigerator of cap 165-195Ltrs of existing make or any other make as specified.
Compressor unit for Refrigerator of cap 200-320Ltrs
Compressor unit for Refrigerator/Deep freezer of cap 200-400Ltrs
Starting relay suitable for existing refrigerator. Make: SRIRAM or equivalent make as specified .
Thermostatic switch auto defrost type with knob suitable for existing refrigerator
Bulb inside the refrigerator suitable for existing refrigerator
Magnetic rubber door gasket suitable for existing refrigerator
Push type door switch suitable for existing refrigerator
Door lock with two keys suitable for existing refrigerator
Overload protector suitable for refrigerator . Make: INDFOSS/DANFOSS or equivalent make as specified.
Strainer pencil type alongwith capillary tube suitable for refrigerator as per existing capacity
Electronic PCB for 260-400 Ltr refrigerator /Deep freezer
Taking out and servicing of desert cooler of any capacity i.e. checking of desert cooler fan motor, submersible pump, socket point, PVC connections,Fan blade, wooden chips etc complete all as specified and directed .
M&L for cutting of burnt winding of fan motor of size upto 450mm sweep and rewinding with super enamelled copper winding wire and replacing gun metal bush shaft. complete all as specified and directed.
M&L for painting of desert cooler inner and outer surface using one coat of red oxide and two coat of anti corrosive synthetic enamal paint of approved brand with spray gun complete all as specified and directed.
S & F of Fan Motor copper wound 16/18" sweep, 3 Speed single phase 230V AC supply complete with Blade complete all as specified and directed. (Make: Khaitan /Crompton Greaves/Bajaj)
M & L for MS Bracket with mounting ring of cooler fan motor and mounting clamps/legs of existing size/model complete all as specified and directed
S & F of PVC submersible Pump complete single phase 230V AC supply for desert cooler, 1 meter head or suitable to existing desert cooler complete all as specified and directed. Make: Khaitan/Crompton Greaves/ Bajaj
S & F of PVC front grill of any size as per existing including nuts, bolts & washers complete all as specified and directed
M & L for Side panel/shutter made out of 20 SWG GI sheet as per existing design and approved including handles (2 Nos.) duly welded / riveted complete all as specified and directed
M & L for Bottom tank made out of 20 SWG GI sheet as per existing unserviceable tank complete all as specified and directed
M & L for Top of the Desert Cooler made of 20 gauge GI Sheet riveted /bolted to match with existing complete all as specified and directed.
S & F of PVC water distribution cup with PVC elbow and pipe for any size of cooler complete all as specified and directed
S & F of Capacitor cap- 4/6 MFD, suitable for desert cooler as per existing size. Make: L&T/Epco/Khaitan
S & F of Piano switch 5 amps one way complete all as specified and directed.
S & F of 3 pin plug top 5 Amp complete all as specified and directed.
M & L for twin core 1.5 Sqmm copper conductor wire for internal wiring complete all as specified and directed.
S & F of Float valve PVC 15mm bore, heavy duty complete all as specified and directed.
S & F of PVC connection 60 cm long complete all as specified and directed.
M & L for Wooden chips pad of suitale size for 03 side shutters of desert cooler min 600gm in weight complete all as specified and directed..
M & L for PVC insulated and sheathed flexible 1100 volts grade 3 core multistranded copper conductor of size 2.5 sqmm complete all as specified and directed. .
S & F of 3 pin plug top 15 Amp complete all as specified and directed. .
S & F of brass stop cock ,cast copper alloy, screwed down, high pressure,with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed suitable for 15 mm bore pipes complete all as specified and directed.
S & F of brass stop cock , cast copper alloy, screwed down, high pressure,with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed suitable for 20 mm bore pipes complete all as specified and directed.
Supply & Fixing plywood 6mm thick duly fixed in windows with screws for ventilation opening for desert cooler as per existing size complete all as specified and directed by Engr in Charge.
Supply, fixing and grouting of MS Stand (adjustment type) suitable for desert cooler of cap 3000/4000CFM made out of angle iron section as per site requirement and as with two coats of synthetic enamel black paint over a coat of red oxide primer all as specified and directed by Engr in Charge.
S&F in replacement GI pipe, 15 mm bore, medium grade, ISI marked with fittings laid in trenches or fixed to walls, ducts, floors etc incluiding necessary excavation and earth work complete for desert cooler/water cooler connections all as specified and directed by Engr in charge.
Ditto all as per Srl Item No 22 here in before but of 20mm bore
M&L for servicing of exsting servo voltage stabilizer three phase upto 10KVA capacity incl minor repair such as internal wiring,indication bulb etc incl disconnection from supply and restore electric supply after minor repair/servicing all as specified and directed by Engr-in-charge.
M&L for Dehydration of transformer oil for servo voltage stabilizer after disconnecting all connections and taking down from mounting structure or foundation and placing in a safe and dust free zone as indicated and removing the tank plate cover without damaging anyother parts and drying out the oil and pouring into the dehumidifier aparatus at site in front of Engineer-in-Charge and after dehumidification process, re-filling of oil into the oil tank , placing at existing position after covering up with sheet cover without making any leakage by providing adequate cork sheet packing etc, testng of oil and confirming the di-electric strength more than 30 mega Ohm complete all as specified and directed.
M&L for Filling up transformer oil for servo voltage stabilizer for top up after removing oil tanks cover plate carefully without damaging any kind of parts by arranging all kind of safety measures, testing after filling up and confirming the di-electric strength not less than 60 KV Ohm as per IS Standard complete all as specified and directed.
Material and labour for chemical earthing complete with copper earth plate electrode of size 600mm x 600mm x 3 mm thick buried directly in ground(earth pit not less than 2.25m deep below normal ground level) with top edge of the plate not less than 1.5m deep below normal ground connected to and including copper earth strip 25 x 3 mm by means of copper bolts nuts check nuts and washer, returning & filling the pit with excavated soil mixing with charcoal 250 KG , Crystal salt 200KG , magnesium sulphate of 100 KG and vegetable soil all around the plate up to 350mm above from top edge of plate and balance portion filing with excavated soil in layers not exceeding 25mm thick, 25mm bore galvanised iron medium grade watering pipe up to top of plate, 50mm bore galvanisd iron light grade pipe for earth strip protection, including all excavation earth work in any type of soil, PCC 1:3:6 type C1 for chamber of internal size 300mm x300 x 300mm with 120mm thick wall and 700 mm x 700mm x 150mm thick, bed concrete, RCC 1:2:4, type B1 for precast chamber cover 50mm thick, reinforced with welded steel wire fabric or XPM jali (weight not less than 4.00 Kg/sqm), funnel, with wire mesh, complete all as specified and directed. Note:- (i) Cost of GI pipe upto 7.5 metre for protection of earth strip deemed to be included in quoted rate. (ii) Cost of upto 7.5 metre earth lead strip deemed to be included in quoted rate.
S&F in repair of following items for single phase voltage stabilizer cap- 3 to 5 KVA
Replacement of buck boost PCB for voltage connection
Display Unit
Auto Transformer
S&F in repair of following items for single phase voltage stabilizer cap- 1 to 2 KVA
Replacement of ball boost PCB for voltage connection
Display Unit
Auto Transformer
S&F online UPS with maintenance free battery of 02X200AH complete connect to relay unit of control panel to uninterrupted electric supply to VCB/ office/installation incl battery terminal complete all as specified and directed by Engr-in-charge.
S&F modular enclosure of single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB of 25 Amps, 240 volts. Make- L&T, Havells, Legrand complete all as specified and directed by Engr-in-charge.
Supply, laying, testing & commissioning LT XLPE insulated armoured (heavy duty) electric cable with stranded aluminium conductor 1100 volts grade (ISI marked) & laid in trenches/pipes or fixed on pole of the following sizes:-
16 Sqmm 4 core
10 Sqmm 2 core
M&L submain wiring complete with 6 Sqmm single core multi standred PVC insulated and sheathed cable FRLS copper conductor four runs and one run of 6 Sqmm copper cable for earth continuity conductor in and including drawn through PVC conduit with all PVC accessories fixed on wall, floor/ceiling etc complete all as specified and directed.
M&L concealed submain wiring complete with 6 Sqmm single core multi strandred PVC insulated and sheathed cable FRLS copper conductor two runs and one run of 6 Sqmm copper cable for earth continuity conductor in and including drawn through PVC conduit size not less than 20 mm dia with all PVC accessories complete all as specified and directed. Note: Two runs of 6 sqmm , one run of 6sqmm earth conductor and PVC conduit pipe shall be measured as one length only.
M&L concealed submain wiring complete with 4 Sqmm single core multi srtandred PVC insulated and sheathed cable FRLS copper conductor two runs and one run of 4 Sqmm copper cable for earth continuity conductor in and including drawn through PVC conduit size not less than 20 mm dia with all PVC accessories complete all as specified and directed. Note: Two runs of 6 sqmm , one run of 6sqmm earth conductor and PVC conduit pipe shall be measured as one length only.
unique traders
PD GUPTA AND COMPANY
M/S SHARADA ASOCIATE
M/S MAKHIJA TRADERS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .