SE EWC AYODHYA
OFFICE OF THE SUPERINTENDING ENGINEER ELECTRICITY WORKS CIRCLE AYODHYA
105/SE/EWC/AYO/2023-24
2023_MVVNL_863559_1
105/SE/EWC/AYO/2023-24
Open Tender
Electrical Works
Item Wise
30 days
AMETHI
Please refer Tender documents.
2 documents required · 2 mandatory
₹3,540
SUPERINTENDING ENGINEER, ELECTRICITY WORKS CIRCLE
₹10,900
14 Dec 2023
21 Nov 2023
29 Nov 2023
21 Nov 2023
29 Nov 2023
21 Nov 2023
Amount
Safe Loading, Carriage and then safe unloading of the following material from Store Centres Under the jurisdiction of EE ESD Ayodhaya to dump site proper stacking.
PCC pole 9 Mtr.
STP 11 Mtr.
M.S. Top Channel 125x65 mm 3200 mm
M.S. Angle 65x65x6 mm Bracing, 4300 mm
MS Angle for guarding 65x65x6 mm, 3500 mm long
GI Wire 8 SWG
GI Wire 6 SWG
33 KV Disc Insulator B & S Type polymer
33 KV V Type channel cross arm
33 KV Pin Insulator polymer type
Stay Wire 7/8 SWG
ACSR Dog Conductor
33 KV 3x120 sq mm XPLE Cable
33 KV Outdoor jointing Kit for 3x120 sq mm XLPE Cable
33 KV S/T Jointing kit
Safe Dragging/ Loading - unloading from dump site to pit site and Fabrication & erection of Single Pole for 33 KV Line on 11 Mtr ST Pole with fitting of necessary clamp & other acessories like 1 No. Channel Cross Arm,3 NO. Pin insulator as per norms. (Contractor shall provide necessary clamps, F-brackets, Nut - Bolts, Washers etc.)
Safe Dragging/ Loading - unloading from dump site to pit site and Fabrication & erection of Single Pole for 33 KV Line on 9.0 Mtr PCC Pole with fitting of necessary clamp & other acessories like 1 no Channel Cross Arm,3 NO. Pin insulator as per norms. (Contractor shall provide, necessary clamps, F-brackets, Nut - Bolts, Washers etc.)
Safe Dragging/ Loading - unloading from dump site to pit site and Fabrication & erection for Sectional Double pole for 33 KV Line on 9.0 Mtr PCC Pole with fitting of necessary clamp & other acessories like 1 No Top channel of 125x65x6 mm size 3200 mm, 6 No. Disc. Fitting , Bracing angle 1 set., Disc insulator 6 No. and 3 No. Pin insulator as per norms. (Contractor shall provide E- Bracket , necessary clamps, Disc Fitting, Nut - Bolts etc.)
Erection of single stud pole support on PCC Pole 9.0 Mtr long with fixing of necessary clamps and other accessories required for erection. (Contractor shall provide necessary clamps, Nut - Bolts, Washers etc)
Cradle Guarding of 33 KV line at road crossing, 11 KV line crossing, canal/telephone line crossing by fixing Guarding Angle 65x65x6 mm, 3500 mm at double pole and 2600 mm long at single pole by stringing and sagging of 3 No. G.I.wire with lacing and tightening with mounting. (Contractor shall provide Necessary clamps for fitting of guarding angle and 6 No. Eye Bolt 12x110 mm etc.)
Nozeling and grouting of stay at sectional pole and extra stay sets at angle locations (All the civil material and stay set, stay clamp will be arranged by the contractor except stay wire)
Stringing, sagging, binding and Jumpering of ACSR Dog conductor. 3 Phase of 33 KV Line including fixing, mounting of P.G.clamp suitable for Dog Conductor at sectional point. (Contractor shall provide necessary PG clamps etc)
Laying & Dressing of 3x300 sq. mm XLPE Cable underground single Circuit. Laying of single circuit 3x300 sq .mm XLPE Cable in normal soil by digging of trench 1050 mm deep, 750 mm wide including supply of required materials, as 1st class Bricks, Stone slabs and fine sand. Providing 150 mm fine sand cusion beneath, and 150 mm sand cusion above the cable. The cable shall be duly protected by Bricks, sand and stone slab. The inter axial spacing between two cables should be in between 0.25 to 0.04 M. After laying the cable refilling and ramming of the left out soil,closing the trench and leveling.
Installation of Heat Shrinkable Type cable jointing kits of following types/sizes for 33 XLPE Cable.
(a) Fixing of 33 KV 3x300 sq. mm Straight Through joints. (jointing kit supplied by dept.)
(b) Fixing of 33 KV 3x300 sq. mm Outdoor End Terminations (jointing kit supplied by dept.)
High Pressure testing to which 33 KV Line & cable to be stand for duration of 5 minutes after completion of Laying, Stringing, sagging, binding and Jumpering of ACSR Dog conductor. ( Testing equipment will be arranged by the contractor)
Hoisting of 33 KV Cable on existing/erected support with provision of MS Pipe 150 mm dia 3 mtr long suitable for 3x300 sq mm cable fixing of proper support and its clamping, providing long barral lugs 6 nos and P.G. Clamps & "Y" shape jumpering properly and 02 nos. supporting angle 65X65X6, 2240 mm long and making connection including supply of jumpering cable ,mounting clamps as per RESSPO Norms. (All material will be supplied by the contractor like M.S Pipe , P.G. Clamps, Al. Lug And Supporting Angle 65X65X6, 2240 mm and jumpering cable suitable for 33 KV jumper).
Grouting of following structure by digging of pit 1.5 Mtr/1.83 Mtr deep for 9.0 Mtr PCC / 11 Mtr STP respectively, placing stone pad at bottom 450x450 size foundation is provided with help of steel or wooden formers, groutung with 1:4:8 Ratio cement, sand & first class brick ballast 0.268/0.285 cu mtr for 9.0 mtr PCC Pole & 11 mtr STP, plinthing 0.3 Mtr above G/L and proper plastering.
11 Mtr ST Poles
9.0 Mtr PCC pole
Supply and fixing of a stone pad of size 300x300x75 mm at PCC/STP Bottom of the pit ( Contractor shall provide all materials)
Fixing of barbed wire on pole Supply and fixing of barbed wire on the pole above 2750 mm ground level. Barbed wire wrapped for a distance of 0.9 mtr. with a pitch of 13.mm at a height. (All materials supplied by the contractor)
Fixing of Danger board . Supply and fitting of Danger board of size 250x200x2 mm 3650 mm above ground level as per Respo norms. RESPO Drawing No-55
Fixing of Number plate . Supply and fitting of Number plate of size 250x200x2 mm 3650 mm above ground level as per Respo norms. RESPO Drawing No-55
Replacement of old and damage pin insulator with all fittings by new pin insulator at required places (except pin insulator)
Fixing of additional V-type X arm with clamp, nut & bolts etc. at required places. (Contractor shall provide clamp nut & bolts etc).
Fixing of additional Bracing angle 65x65x6 4300 mm with clamp, nut & bolts etc. at required places. (Contractor shall provide clamp nut & bolts etc).
Fixing of additional disc insulator B&S with clamp, nut & bolts etc. at required places. (Contractor shall provide clamp nut & bolts, 33 kV disc fitting etc.)
Angle for Cross arm Support at Angle Location 65x65x6 mm 1600 mm long with clamps and nut & bolt. (All materials will be supplied by the contractor)
Petrolling in feet from starting to end and removal/lopping and chopping of tree branches which are lying in routre of 33 KV overhead line.
Providing and fixing at the top of the pole Pcc & Stp Extension piece 1.5 mtr channel 125x65 mm and required places ( crossing of lines etc) and supporting with clamp and all fittings. (All materials will be supplied by the contractor).
Opening of binding of loose old ACSR DOG Conductor, Tightening, stringing, binding and Jumpering of loose old ACSR Dog conductor in all respect. 3 Phase of 33KV Line including fixing,mounting of P.G.clamp suitable for Dog Conductor at sectional point. (All the material will be arrange by the contractor)
Straightening of additional existing erected/tilted pole with Digging & grouting at required places (All the civil material will be arranged by the contractor) Grouting of structure by digging of pit 1.5 Mtr/1.83 Mtr deep for 9.0 Mtr PCC / 11 Mtr STP respectively, placing stone pad at bottom 450x450 size foundation is provided with help of steel or wooden formers, groutung with 1:4:8 Ratio cement, sand & first class brick ballast 0.268/0.285 cu mtr for 9.0 mtr PCC Pole & 11 mtr STP, plinthing 0.3 Mtr above G/L and proper plastering.
Providing of HDPE 6"Dia Pipe PN-6 Specification
Laying of cable & HDPE Pipe Laying of Single circuit 33 KV 3x300 Sq mm XLPE cable and HDPE Pipe by drilling method below NHAI road crossing. The cable be laid at the depth of 3 mtr from the under surface in HDPE pipe (200 mm. dia.) casing.
Permission of NHAI/PWD etc. for road crossing. .( Final settlement of the payment will be done after providing receipt, agreement and permission paper) which is less coted by contractor of demand by NHAI/PWD.
Painting of poles Painting of poles with one coat of red oxide, two coats of enamel paint ISI mark. (All required material will be supplied by the contractor)
Fault locator for old and existing 33 kv line and repairing of the calbe by installing S/T jointing kit if requerd upto energisging the 33 kv line.
M/S INDIA ELECTRICALS
M/S SANTOSH KUMAR CONSTRUCTION
tech_bid_open.pdf
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .