Loading…
Loading…
Tender Value
₹1.3 Cr
EMD Value
₹2.6 L
Closing Date
7 May 2026, 3:00 pmClosed
No
No
Single Packet System
Normal Tender
No
Not Applicable
Lowest to Highest
60 days
Expenditure
+ Capital Works)
Above/Below/Par
ENHM
15 conditions · 2 needing a document upload
The tenderer must have minimum average annual contractual turnover of V/N or V whichever is less ; where V= Advertised value of the tender in crores of Rupees N= Number of years prescribed for completion of work for which bids have been invited. The average annual contractual turnover shall be calculated as an average of "total contractual payments" in the previous three financial years, as per the audited balance sheet. However, in case balance sheet of the previous year is yet to be prepared/ audited, the audited balance sheet of the fourth previous year shall be considered for calculating average annual contractual turnover. The tenderers shall submit requisite information as per Annexure-VIB of GCC of works, along with copies of Audited Balance Sheets duly certified by the Chartered Accountant/ Certificate from Chartered Accountant duly supported by Audited Balance Sheet.
Note: In case, date of tender inviting is on or after date of statutory deadline for audit of balance sheet of previous FY (i.e. 30th Sept or as further extended for this FY), audited balance sheet of 4th previous year shall not be considered unless concerned CA certifies that balance sheet is not audited yet as on date of invitation of this tender.
(a)The tenderer must have successfully completed or substantially completed any one of the following categories of work(s) during last 07 (seven) years, ending last day of month previous to the one in which tender is invited: (i)Three similar works each costing not less than the amount equal to 30% of advertised value of the tender, or (ii)Two similar works each costing not less than the amount equal to 40% of advertised value of the tender, or (iii)One similar work costing not less than the amount equal to 60% of advertised value of the tender.
Similar work shall mean by "Construction/Operation of Effluent Treatment Plant / Automatic Coach Washing Plant /Sewage Treatment Plant/ Water Recycling Plant or Mechanized Cleaning work of railway station/Coaches /Hospitals /Building in Railway /PSUs and other Government /Semi Government departments, public listed company, private company and Trusts having annual turnover of Rs 500 crore and above. Work experience certificate from private individual shall not be considered. However, in addition to work experience certificates issued by any Govt. Organization, work experience certificate issued by Public listed company having average annual turnover of Rs 500 crore and above in last 3 financial years excluding the current financial year, listed on National Stock Exchange or Bombay Stock Exchange, incorporated/registered at least 5 years prior to the date of closing of tender, shall also be considered provided the work experience certificate has been issued by a person authorized by the Public listed company to issue such certificates. In case tenderer submits work experience certificate issued by public listed company, the tenderer shall also submit along with work experience certificate, the relevant copy of work order, bill of quantities, bill wise details of payment received duly certified by Chartered Accountant, TDS certificates for all payments received and copy of final/last bill paid by company in support of above work experience certificate.
1 condition
Please enter the percentage of local content in the material being offered. Please enter 0 for fully imported items, and 100 for fully indigenous items. The definition and calculation of local content shall be in accordance with the Make in India policy as incorporated in the tender conditions.
Supply, Installation & Commissioning of Effluent Treatment Plant (ETP) 100 KLD Cap. for BKN Laundry & 50 KLD Cap. For HSR Laundry along with operation & maintenance of the plant for Two years on Turnky basis.
02-Mech-EnHM-2025-26
02-Mech-EnHM-2025-26
Open
Works - General
30 Months
Bikaner, Rajasthan
₹0
₹2.6 L
7 May 2026
14 Apr 2026
23 Apr 2026
8 items across 2 schedules
| # | Description | Unit | Qty | Rate | Amount |
|---|---|---|---|---|---|
| Supply, Unloading, Erection and Commissioning of Pre-fabricated Effluent Treatment Plant (ETP) complete including foundation, from inlet point of ETP to outlet point of ETP, of 100 KLD (kilo liter per day) capacities of approved quality and design and of 2 years warranty, with flow meters at inlet and outlet. The design should be approved by the Central Pollution Control Board or any of the State Pollution Control Boards and the same should be submitted to the Railways. The treated inlet water should have the physical and chemical properties mentioned in the list attached. The work will include all the Civil, Electrical and other works which are directly related to the ETP (ie. between inlet point of ETP to outlet point of ETP) such as earth work excavation, plain cement concreting, construction of control panel room and other necessary buildings (if required), electrical works, as directed by the Engineer - in - Charge. The contractor should submit the water test results of both discharge and treated water after commissioning of the plant. At Bikaner. The supply of Electricity to the ETP point, will be managed by Railway | — | 1.00 | — | — | |
| Horizontal direction drilling/boring without damage of surface road /track using Auger Machine (HDD machine). The bore shall be up to 200 mm dia & shall be done at the depth of 1200 mm to 3000 mm from the ground level. The ground level shall be considered ignoring the bank height of the bank of the road. The length of the bore shall be minimum 4 Mtrs long. This includes insertion of different dia DWC-HDPE pipe/ GI pipes coupling etc. as per direction of Engineer In charge. Note:- Pipe Supply is not covered under this item | — | 300.00 | — | — | |
| Integration and Providing & fixing of 50 mm GI (B Class Medium) pipeline with complete GI fitting including trenching and refilling etc. for transferring watering. Mak - Jindal ,StarTata ,Surya Roshni | — | 1250.00 | — | — | |
| Supply, installation and commissioning of electrical operating Sludge pump of Suitable capacity and water lifting pump of capacity 5 H.P. Make- Crompton, ABB, Havells, Siemens, Kirloskar , CG Power, | — | 4.00 | — | — | |
| Supply, Unloading, Erection and Commissioning of Pre-fabricated Effluent Treatment Plant (ETP) complete including foundation, from inlet point of ETP to outlet point of ETP, of 50 KLD (kilo liter per day) capacities of approved quality and design and of 2 years warranty, with flow meters at inlet and outlet. The design should be approved by the Central Pollution Control Board or any of the State Pollution Control Boards and the same should be submitted to the Railways. The treated inlet water should have the physical and chemical properties mentioned in the list attached. The work will include all the Civil, Electrical and other works which are directly related to the ETP (ie. between inlet point of ETP to outlet point of ETP) such as earth work excavation, plain cement concreting, construction of control panel room and other necessary buildings (if required), electrical works, as directed by the Engineer - in - Charge. The contractor should submit the water test results of both sewage and treated discharge water after commissioning of the plant at Hisar. The supply of Electricity to the ETP point, will be managed by Railway | — | 1.00 | — | — |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
HTML
nit.pdf
NIT
GCC_April-2022.pdf
ATTACHMENT
CorrectionslipGCC2022.pdf
ATTACHMENT
TenderDocETPHSRBKN_1.pdf
ATTACHMENT
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .