Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Tender Value
₹24.2 L
EMD Value
₹4.8 L
Closing Date
22 Feb 2024, 8:30 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Bangalore Electricity Supply Company Limited
GIRIJA V C
Preventive and Breakdown maintenance of all makes of DAS and Non DAS RMUs of all configurations in BRAZ area of BESCOM for a period of two years on total turnkey percentage quoting basis
BESCOM/2023-24/EL/WORK_INDENT101
BESCOM/2023-24/EL/WORK_INDENT101
Open
Electrical
Two Tender Document System(Two Cover)
BESCOM Corporate Office Procurement section Bengaluru
3 documents required · 2 mandatory · 1 optional
The Liquid Assets as on 31.01.2024 of or at a later date before submission of the bid consisting of Cash at Bank plus Term Deposits plus availability of fund based credit facility in any Nationalized/ scheduled commercial Bank shall not be lesser than 12.5% of the amount put to tender.
The Annual Turnover of the Bidder in at least two financial years should not be less than the amount put to tender in any of the previous five financial years (i.e., FY 2018-19, 2019-20, 2020-21, 2021-22 & 2022-23).Note: The previous years turnover of the Bidder is updated to the FY in which the tenders are invited. Financial turnover of previous years shall be given a weightage of 10% per year to bring them to the price level of the FY in which the tenders are invited
Litigation History:The Bidder should provide detailed information on any litigation or arbitration arising out of contracts completed or under execution by it over the preceding five years, A consistent history of awards involving litigation against the Bidder or any partner of Joint Venture may result in rejection of Bid.
Even though the Bidders meet the above criteria, they can be disqualified if the Bidder i.has made misleading or false representations in the forms, statements and attachments.ii.has record of poor performance such as abandoning the works, not properly completing the contract, inordinate delays in completion, litigation history, or financial failures etc. iii.has participated in the previous Tender for the same work and had quoted unreasonably high tender prices and could not furnish rational justification.
The Bidder can be disqualified if the Bidder have Defaulted/short closed due to non-performance in execution of works against the order placed any Public Electrical Utility/Govt. utility as on date of bid submission.
The Bidders can be disqualified if the Bidder is Black-Listed by any Public Electrical Utility/Govt. utility as on the date of bid submission.
Bidder who meets the above criteria, will only be qualified, if their available tender capacity is more than the total tender value. The available tender capacity will be calculated as under:Assessed available tender capacity equals to (AxNx1.5-B) Where, A is the Maximum value of works executed in any one year during the last five years (updated to FY 2023-24 price level), taking into account the completed as well as works in progress. N is Number of years prescribed for completion of the works for which tenders are invited.B is equal to Value, at FY-2023-24 price level, of existing commitments and on-going works to be completed during the next 24 months Note: The previous years turnover of the Bidder is updated to the FY in which the tenders are invited. The value of the completed works shall be given a weightage of 10% per year to bring them to the price level of the FY in which the tenders are invited.
The Bidder should have successfully executed the work of Maintenance of different makes of RMUs for a minimum of 40% of the proposed RMUs in similar nature of tendered work in any one year of the preceeding 3 (three) years in ESCOMs/Govt. Electrical Utilities/PSUs as a prime contractor, as on date of bid submission.
The Bidder should have satisfactorily completed at least One Electrical work for not less than 50% of the Amount Put to Tender in ESCOMs/Govt. Electrical Utilities in any one year of the preceding 3 (Three) Years (FY 2020-21, 2021-22 & 2022-23) as on the date of Bid Submission.Note: The value of the completed works shall be given a weightage of 10% per year to bring them to the price level of the FY in which the tenders are invited.
The Bidder should possess a valid Super Grade/Class-1 Electrical Contractors License issued by Electrical Inspectorate, Government of Karnataka as on the date of Bid Submission.
The Bidder should have minimum 3 (three) years experience in repair and Maintenance of RMUs in ESCOMs/Govt. Electrical Utilities as on the date of bid submission.
The Bidder should be a registered Proprietorship Firm or a Partnership Firm or a Registered Company incorporated under Companies Act 1956/2013.
Any Bidder from a country which shares a land with India will be eligible to bid in this tender only if the Bidder is registered with the Competent Authority of India. (as per the Govt. order No. FD 455 Exp-12/2020 dated:25.08.2020)
A certificate for having read the clauses is required to be submitted/uploaded by the tenderer separately as below:I have read the clause regarding restrictions on procurement from a Bidder of a country which shares a land border with India: I certify that this Bidder is not from such a country or, if from such a country, has been registered with the Competent Authority. I hereby certify that this Bidder fulfills all requirements in this regard and is eligible to be considered.
The Bidder should have a functional office located in Bengaluru. Self-declaration mentioning the complete office address and contact details with documentary proofs shall be uploaded.
₹610
₹4.8 L
2 Feb 2024
2 Feb 2024
23 Feb 2024
6 Feb 2024
6 Feb 2024
Preventive and Breakdown maintenance of all makes of DAS and Non DAS RMUs of all configurations in BRAZ area of BESCOM for a period of two years on total turnkey percentage quoting basis
OD Operating Mechanism
VL Operating Mechanism
Motor 48V DCor 24V DCor 110V DCor 230V AC
Batteries 26or A, 32A
Single Pole MCB
Auxiliary Switch VL
Auxiliary Switch OD
Terminal Blocks
2.5 Sqmm Wire (RYB and Black )
25 Sqmm Cable CT and PT Connection
Multi Function Meter
Battery Charger 24V 10A or 24V 5A or 12V 5Aor 12V 10A
Local Remote Switch
VPI Indicator Sets
Surge Arrestors
Auxilliary Transformer (AT)
Potential Transformer (PT)
Current Transformer 200
Current Transformer 400
Surface Heaters
Cable Box Interlock
Shunt Trip Coil
24V DCor 110V DCor 220V DCor 230VAC
Operating Handle Manual or Motorised
Door Dampnersor Hydraulic Rods
22.5mm Dia Two Position Selector Actuator
Isolator Mechanism (Safe Plus)
VCB Mechanism (Safe Plus)
Mechanism For C Functionor Disconnector
LLI LED VPIS Densing Cable Assemble (Safe Plus)
24V DC Spring Charge Motor
Manometer with Remote Switch
Self Protectrion Relay ADR241S
Self Protectrion Relay ADR141S
Ring Switch Mechanism
Aux Switch C Function Suitable for AB3
Aux Switch for T2 Function
MFM Metering CICT 400 200or 1A, CL 0.5, 5.2VA
Mechanism Inter Lock Assemble
Power Supply Assemble
Cable Tie 50or 100or 200 cm Suitable for RMU
OD Internal Operating Mechanism
VL Internal Operating Mechanism
VL Vaccum Bottles
Fiber Moving Contact With Copper Shaft
Internal Mechanism Fiber Box
Operating Mechanism Shaft
Inter Lock Card
RMU Partial Control Wiring
RMU Major Control Wiring
0.50 Sqmm Wires
Bush Safety Plate
Connecting Bush
Bush Connecting Alluminium Shaft
Bush Connecting Copper Shaft
Stainless Steel Plateor Sheet
Bush Safety Rubber
Flair 22D Lithium Dual Powered
GAS Pressure Indicator
Standard Magnet 60Vor DC for Realy
Bushing Assemble (Safe Plus)
Isolator Mechanism (Safe Link)
VCB Mechanism (Safe Link)
VCB Mechanical Bushing with Linkage with Protector
2PA Mechanism wor o Hex Rod
CT Assemble Kit
Front Door Locking Assemble
220or 240V LC Protector
RS485 Communication two core cable with Earth Sleeve
Flexible Bus Bar
Vaccum Bottle Housing
ABB Supporting Insulators
Dooror Metal Sheets
Gland Plates with cable clamp
V.T Spout Insulator VR5
Support Insulator VR5 only.
Castel Lock+Key VR 5 Only
Breaker Raising Lowering Gear VR5 ONLY
Breaker Raising Lowering Gear VR5 ONLY
Main Lever Assly VR5
Main Connecting Rod Assly VR5 ONLY
Insulated Housing Assly VR5 ONLY
Switch Insulator RHand LH VR5 ONLY
Switch Insulator Middle VR5.
Switch stem Assly LH and RH VR5.
Limit Switch Assly VR5
LINK RH VR5 ONLY
LINK LH VR5 ONLY
Shutter Box Asslyor Retro AC1 by VR5 also.
Guide Bracket LH VR5 ONLY
Guide Bracket RH VR5 ONLY
Shutter Assly VR5 ONLY
Auxilliary Plug Base Assly VR 5
Switch Stem Assly Middle VR5 ONLY
Aux Switch Operating Link and Lever Assly VR5
Phase Barrier Assly VR5
Ramp for VR5 breaker
Centre sheet. VR5
Phase Barrier.VR5
Connecting Jump R.VR5
Connecting Jump Y.VR5
Connecting Jump B.VR5
Switch insulator support.VR5
Fixed shutter barrieror Shutter Plate. VR5
Top Cover Shut 1600x4x4x3.VR5
Phase Barrieror Barrier Support. VR5
Top Cover Sheet. VR5
Terminal Assly VCRMU
Finger Contact Assly. Power gear
Bus bar insulator (Double).
Bor B Support Insulator VCRMU
Epoxy Cost Bus Bas(Bor B) Support Insulator VCRMU
Spring Charging Handle Assembly
Al Jumps, R Phase VCRMU
Al Jumps, Y Phase VCRMU
Al Jumps, B Phase VCRMU
Upper Terminal[SF6] VCRMU
Lower Terminal[SF6] VCRMU
Finger Contact VCRMU
Alu Bus Bar R, Y, B, 6x50x528,10x50x528VR5
Screw Rod VCRMU
Lower Terminal [VCRMU VB5 type Kirloskar type
Upper Terminal [VCRMU VB5 type Kirloskar type
Upper Terminal VCRMU
Lower Terminal VCRMU
Finger Contact VCRMU
Grid Sheet VCRMU
Upper Support Block [Btw Terminal Fibre]VCRMU
Lower Support Block [Btw Terminal and Fibre] VCRMU
Upper Terminal Lifter VCRMU
Lower Terminal Lifter VCRMU
Plug Assly For Grid 800A. VR 5 P
Spout Insulator Grid Assly (B)
Earth switch Assly
Spout Insulator Grid Assly (F
Bushing for Bus Bar Cable Box
Bus bar Support Insulator (Single) Insulator or Insert
Finger Contact Assly. Power gear
Brass Hex. Nut Thin (1 Inches)
Brass Hex. Nut Thick(1 Inches)
Conversion from Manual Operated to Motor Operated with DAS compatible RMU breakers
Value of Consumables (Minor Spares) (Per unit is equal to Per RMU)
Preparation of RMU Surface for painting by removing of old rusted part and removing of posters etc and applying One coat of primer paint and painting with new paint using Compressor machine, transport...
Anti poster grill supplying and fixing including chain link mesh, angle welding charges etc (Per Unit is equal to Per Sq. Mtr.)
Civil work including renovation of RMU foundation by providing basic concrete work, plastering etc... (Including required material and labour cost) (Per Unit is equal to LS)
Cutting of stainless steel tank using cutters, removal of Bushings etc., Re welding using TIG welding, Stainless steel sheet as required and creating vacuum to clear moisture and refilling of SF 6 G...
Preventive maintenance charges for 3 Way. 4 Way, 5 Way, any other configuration RMU (Per unit is equal to Per RMU)
Breakdown maintenance charges charges for 3 Way. 4 Way, 5 Way, any other configuration RMU (Per unit is equal to Per RMU)
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
BRAZ RMU Techno-Commercial Sheet 02.02.2024.xls
Commercial Information / Worksheet • 0.20 MB
BRAZ RMU Section I IFB 02.02.2024.docx
Tender Document • 0.07 MB
BRAZ RMU Section VI annexures 02.02.2024.docx
Others - ANNEXURES • 0.03 MB
BRAZ RMU Section III GCC 02.02.2024.docx
Others - GCC • 0.05 MB
BRAZ RMU Section IV ECC 02.02.2024.docx
Others - ECC • 0.04 MB
BRAZ RMU Section V SCC 02.02.2024.docx
Others - SCC • 0.04 MB
BRAZ RMU Section II ITB 02.02.2024.docx
Instructions to Tenderers • 0.05 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .