Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹6.7 LAccepted-AOC AT P O BACHRA P S PIPARWAR PIN 829201 | CHATRA | JHARKHAND | 829201 | L-1 | Accepted-AOC As per recommendation of TC and approval of competent authority | |
| 2 | L-2₹9.0 L+₹2.3 L (34.4%)Rejected-Finance AT PO DAKRA KHALARI DIST RANCHI JHARKHAND PIN 829210 | RANCHI | JHARKHAND | 829210 | L-2 | Rejected-Finance As per recommendation of TC and approval of competent authority | |
| 3 | L-3₹10.6 L+₹3.9 L (58.8%)Rejected-Finance | L-3 | Rejected-Finance As per recommendation of TC and approval of competent authority | |
| 4 | L-4₹12.0 L+₹5.3 L (79.8%)Rejected-Finance 4C 1 KESHAR VIHAR NEAR NSF INTER COLLEGE BALAJI PURAM SHAHGANJ AGRA 282010 | AGRA | UTTAR PRADESH | 282010 | L-4 | Rejected-Finance As per recommendation of TC and approval of competent authority | |
| 5 | L-5₹12.1 L+₹5.5 L (82.0%)Rejected-Finance AT DAKRA P O DAKRA DISTT RANCHI JHARKHAND PIN 829210 | DAKRA | RANCHI | JHARKHAND | 829210 | L-5 | Rejected-Finance As per recommendation of TC and approval of competent authority |
Tender Value
₹11.5 L
EMD Value
₹14,500
Closing Date
25 Aug 2023, 5:00 pmClosed
Staff Officer (EnM),M-S Area
Office of the General Manager M-S Area, Bachra . 829201.
Fresh wiring including complete Power distribution line for Meeting/Auditorium Hall near to PPR thana with misc. fittings and 3- Phase service cable connection from main supply line under Magadh - Sanghmitra Area
2023_CCL_286168_1
GM(M-S)/SO(EnM)/e-NIT/23-24/77
Open Tender
Electrical and Maintenance Works
Item Rate
25 days
Office of the general manager M-S Area, Bachra
Please Refer NIT
4 documents required · 4 mandatory
₹14,500
25 Jan 2024
16 Aug 2023
26 Aug 2023
16 Aug 2023
25 Aug 2023
16 Aug 2023
16 Aug 2023 - 24 Aug 2023
Amount
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required. 1.10.1 Group A COST FOR 1 POINT
Providing and fixing following rating and breaking capacity MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required. 2.2.1 100 A 16 KA Details of cost for one each
Providing and fixing following rating and breaking capacity MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required. 315 A 35 KA Details of cost for one each
Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 2.4.1 4 way (4 + 12), Double door Details of cost for one each
Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 6 way (4 + 18), Double door Details of cost for one each
Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 milli amperes in the existing MCB DB complete with connections, testing and commissioning etc. as required. 40 A Details of cost for one each
Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 milli amperes in the existing MCB DB complete with connections, testing and commissioning etc. as required. 63 A Details of cost for one each
Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, 10 kA, “C” curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single pole and neutral Details of cost for one each
2 X 4 sq. mm + 1 X 4 sq. mm earth wire.
Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit alongwith 1 No 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthling as required.
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providng and fixing 2 nos. 3 pin 5/6 amps modularsocket outlets and 2 nos 5/6 amps modular switches, connection etc. as required. (For light plugs to be used in non residential buildings). Details of cost for one each
Supplying and installing following size of perforated painted with powder coating M.S. cable trays bends with perforation not more than 17.5%,, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required. 100 mm width X 50 mm depth X 1.6 mm thickness. Details of cost for 1 No
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 amps modular socket outlet and 15/16 amps modular switch, connection etc. as required. Cost of each.
Supplying, installation, testing and commissioning of following capacity overhead distribution bus trunking with aluminium bus bars having current density of 130 A/ sq cm at nominal current rating in 1.6mm thick IP 42 sheet steel enclosure in convenient sections with provision of tapping points for use on, 3 phase, 4 wire, 415 volts, 50 Hz, A.C. supply including jointing of sections, bends, earthing with 2 runs of galvanised iron strips, all installation accessories etc. as required. 200 A Details of cost for 10 Metres
Supplying, installing, testing and commissioning of following capacity TPN tap off box / plug-in box made of 1.6mm thick sheet steel enclosure duly painted with powder coating on existing overhead bus bar system complete with TPN disconnector FSU and HRC fuses, connections, earthing etc. as required. 100 A Details of cost for one each.
Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, 10 kA, “C” curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. 3 Pole Details of cost for one each
Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. 40 A Details of cost for one each
Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. 63 A Details of cost for one each
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 1.24.1 5/6 amps switch COST FOR EACH
Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required. COST FOR EACH
Supplying and fixing stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. 3 x 2.5 sq. mm. COST FOR 50 METRES
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 6 pin 15/16 amps switch COST FOR EACH
Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required. Details of cost for one Set
Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required. Details of cost for 10 Metres
4-core 50 sq. mm Armoured Aluminium Cable per m
3- Core 16 Sq. mm flexible copper Cable per m
Pannel LED Light 55 watt of make syska/ philips/ bajaj/ havells along with holder. Each
Supply of 100 W LED Street light with fittings. Each
Erection Cost of item number 24, 25, 26, 27 & 28 @ 15%
Total impact of GST for the purpose of CTC
M/S R K Enterprises
SAI ELECTRICALS
R.K.SINGH & CO.
M/S MEHTA ELECTRONICS
Baldeep Construction
stage.html
html • 0.05 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_296298.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .