Loading…
Loading…
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance | Admitted-Finance |
| 2 | Admitted-Finance | Admitted-Finance |
| 3 | Admitted-Finance | Admitted-Finance |
| 4 | Admitted-Finance | Admitted-Finance |
| 5 | Admitted-Finance | Admitted-Finance |
Tender Value
₹40 L
EMD Value
₹80,000
Closing Date
28 Jul 2025, 6:00 pmClosed
GE Golconda
GE GOLCONDA LANGER HOUSE ROAD OPP MILITARY HOSPITAL HYDERABAD TELANGANA-500 008
REPAIR / MAINT OF STREET LIGHTS AND OTHER ASSOCIATED WORKS OF E/M NATURE OF ARTY CENTRE AND 17 DOGRA AREA UNDER GE GOLCONDA
2025_MES_718966_1
8882/E8
Open Tender
Civil Works
Item Rate
270 days
GE GOLCONDA
As per Tender
9 documents required · 9 mandatory
₹500
GE Golconda
₹80,000
Yes
2 Aug 2025
7 Jul 2025
2 Aug 2025
7 Jul 2025
28 Jul 2025
21 Jul 2025
Amount
Taking down existing LED street light fitting from poles and Replace luminaire of any type, 230 volts, AC energy saving and environmental friendly long life versatile, pressure di-cast aluminium including electrical connections and taking down of existing unserviceable luminare complete all as specified and directed.
S&F in repair 60W energy saving and environmental friendly long life LED security street light made up of pressure die cast aluminium housing with high power LED, lens & toughened glass, potted driver and with efficacy of 120lm/W, IP 66 protection including connection with twin twisted unsheathed PVC copper cable of suitable size complete all as specified and directed.
S&F in repair 90W energy saving and environmental friendly long life LED building security street light made up of pressure die cast aluminium housing with high power LED, lens & toughened glass, potted driver and with efficacy of 120lm/W, IP 66 protection including connection with twin twisted unsheathed PVC copper cable of suitable size complete all as specified and directed.
S&F in repair 120W energy saving and environmental friendly long life LED building security street light made up of pressure die cast aluminium housing with high power LED, lens & toughened glass, potted driver and with efficacy of 120lm/W, IP 66 protection including connection with twin twisted unsheathed PVC copper cable of suitable size complete all as specified and directed.
Supply and lay in trenches/fixed to walls/poles etc and commissioning XLPE insulated and PVC sheathed heavy duty LT 1100 Volts grade armoured under ground cable with aluminium conductor of size 2 Core 10 Sqmm including taking out of existing cable complete all as specified and directed. Note :- Earth work excavation, sand cushioning and brick protection shall be measured and paid separately.
All as per item No:05 above but 2 Core 16 Sqmm, complete all as specified and directed.
All as per item No:05 above but 4 Core 16 Sqmm, complete all as specified and directed.
All as per item No:05 above but 4 Core 25 Sqmm, complete all as specified and directed.
Excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5 m in depth for foundation, laying of poles / cable in trenches and getting out in hard/dense soil complete all as specified and as directed .
Returning, filling including spreading, levelling, watering and well ramming in layers not exceeding 25 cms thick complete all as specified and directed.
Removal of surplus soil to a distance not exceeding 50 m and depositing where directed at a level not exceeding 1.5 m above from the starting point complete all as specified and directed.
Supply and spread approved dry river sand for cushioning of cable laid in trenches including watering and consolidation, complete all as specified and directed. Note:- Punned thickness of sand cushioning shall only measured for payment purpose.
M&L for brick, sub class 'B', old size, laid in trenches as cable protection covers, complete all as specified and directed.
S&F Hot press moulded SMC Junction box of size 270 mm x 200 mm x 135 mm with right openable hinged door with two number aluminium bus bars mounted on porcelain insulator including clamps of MS flat iron 25 x 3 mm with bolts and nuts and including one MCB SP upto 6A, 10 KA for ON/OFF street light, fixed on pole including taking down old juction box, complete all as specified and directed.
S&F on / off switch for timer nature switch -02, 8 KW single phase street light timer control including taking down existing nature switch for the street light timer switch, complete all as specified and directed.
All as per item No. 17 hereinbefore but for three phase timer of 12KW, complete all as specified and directed.
S&F contactor 8KW suitable for single phase street light timer control unit of existing make and model as per site requirement, incuding taking down existing unserviceable contactor of any description complete all as specified and directed.
All as per item No. 19 hereinbefore but for 12KW, complete all as specified and directed.
S&F Driver circuit board 45W with necessary wiring including taking down exisitng driver circuit board from street light pole of any make, complete all as specified and directed.
S&F Driver circuit board 60W Model with necessary wiring including taking down exisitng driver circuit board from street light pole of any make, complete all as specified and directed.
S&F Driver circuit board 90W with necessary wiring including taking down exisitng driver circuit board from street light pole of any make, complete all as specified and directed.
S&F Driver circuit board 90W with necessary wiring including taking down exisitng driver circuit board from street light pole of any make, complete all as specified and directed.
S&F Surge protector device for street light fitting of any make/type with necessary wiring including taking down exisitng surge protector device from street light pole, complete all as specified and directed.
S&F Steel tubular swaged pole complete with cast iron base plate, finial taper plug, bolts, nuts, screws as specified type 410 SP-31 (9.00 metre long) including two coats of bituminous paint internally and externally for the portion embedded in concrete and two coats of aluminium paint over one coat of red oxide primer to external/ exposed surfaces, including taking down existing pole of any description, complete all as specified and directed. Note: (i) Rate quoted by the contractor shall deemed to includes excavation and earth work, 150mm thick PCC (1:3:6) type C2 (using 40mm graded stone aggregate) below ploe and filled in trench aleound the pole including coping up to 20cm above ground using PCC (1:2:4) type B1 with required formwork complete. (iii) Rate quoted by the contractor shall also deemed to include for taking down carefully the exisitng unserviceable pole, serviceable street light fitting and ACSR conductor including connecting accessories and refixing the same after replacing the new pole with all necessary accessories complete all as specified and directed.
S&F bracket made out of 40 mm dia GI pipe, light grade, 1.5m long, bend to shape including clamps, nuts and bolts etc and required electrical connections including taking out old unserviceable brackets of any description all as specified and directed .
S&F bracket made out of 50 mm dia GI pipe, light grade, 1.5m long, bend to shape including clamps, nuts and bolts etc and required electrical connections including taking out old unserviceable brackets of any description complete all as specified and directed.
S&F PVC insulated and FR PVC round sheathed, copper conductor, flexible industrial cable, 1100Volts, 1.5 Sqmm 2 core for connection from junction box to streetl ight fitting complete all as specified and directed.
S&F PVC insulated and FR PVC round sheathed, copper conductor, flexible industrial cable, 1100Volts, 2.5 Sqmm 2 core for connection from junction box to streetl ight fitting complete all as specified and directed.
M&L for cleaning thoroughly the street light poles/LT distribution poles of any height and any description (Maximum 9 Mtr long ) with necessary cleaning agent including complete removal of existing paint by scrapping etc carefully and applying two coat of synthetic aluminium paint over a coat red oxide primer complete all as specified and directed .
Cutting & trimming of tree branches any girth and size touching to overhead lines and clearing the distance 1.5 mtr both sides of overhead line with in a gap of span 35 to 50 mtrs each and removing the same cleaning the site all as specified and directed.
S&F PVC conduit suitable for 20mm on pole(steel pole/ concrete pole) from juction box to street light fitting for PVC wire complete all as specified and directed.
S&F PVC flexible conduit (size 20mm ) on pole from juction box to PVC conduit & PVC conduit to streetlight fitting complete all as specified and directed.
Supply, Fixing and stringing ACSR Conductor steel reinforced of type as directed including stretching, binding using ACSR conductor on insulator on overhead line including taking down of existing conductor complete all as specified and directed.
Supply, install, test and commission CPRI APPROVED factory fabricated, outdoor type, LT FEEDER PILLAR BOX made out of 3.15mm thick CRCA sheet of size 1M x 0.75M x 0.35M with projected globe roof for rainwater protection dust and vermin proof, double door with both side opening including neoprene rubber gasket, suitable for 440 Volt 3 Phase 4 Wire System, including danger plate, earthing strip point and ventilation louvers at rear side, bottom detachable gland plate complete with suitable size zinc cromium plated nuts, bolts and washers etc. and embeded with 50x50x6mm MS angle iron frame, 600mm above the normal ground level complete with internal connection with suitable size of cable, cable lugs and cable glands, PCC foundation in cement concrete 1:3:6 (20mm graded stone aggregate) complete all as specified and comprising of the following :- (a) Aluminium busbar 200 amps - 04 Nos, supported on suitable size of heavy duty porcelin stand lock with suitable size of brass nut, bolts and washer with heat shrinkable PVC sleeving. The bar shall be colour coded (red, yellow and blue) for three phases and black for neutral. (b) MCCB 100 amps, 415 volt, 16 KA breaking capacity 4 pole electromagnetic release duly connected to busbar as incoming - 01 No.
Supply & Laying 40 mm bore GI tubing, light grade, with all fittings of following sizes for cable protection at road crossing / on poles and tubing sealed at both ends after laying the cables complete all as specified and directed.
SREE KIRAN ENGINEERS (BID ID -3374488)
SRI SAI RAM ENTERPRISES (BID ID -3373175)
M/s. A&T Enterprises (BID ID -3374346)
V.H.Constructions (BID ID -3373464)
SANJEEV CONSTRUCTIONS (BID ID -3370997)
GVR ENGINEERING WORKS (BID ID -3371607)
NAVANAND ENTERPRISES (BID ID -3372930)
STANDARD AGENCIES (BID ID -3374289)
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .