Loading…
Loading…
| # | Company | Quoted % | Amount | Rank | Status |
|---|---|---|---|---|---|
| 1 | L1₹76.3 LAdmitted-Finance | -22.33% | ₹76.3 L | L1 | Admitted-Finance |
| 2 | L2₹76.9 LAdmitted-Finance | -21.70% | ₹76.9 L | L2 | Admitted-Finance |
| 3 | Rejected-Technical SCO 83 2ND FLOOR SWASTIK VIHAR MDC SECTOR 5 PANCHKULA | PANCHKULA | HARYANA | 133301 | - | - | - | Rejected-Technical Affidavit and Bidding capacity not as per DNITT |
| 4 | Rejected-Technical | - | - | - | Rejected-Technical Net worth and Profit loss certificate not as per DNIT |
Tender Value
₹98.2 L
EMD Value
₹2.0 L
Closing Date
23 Feb 2026, 3:00 pmClosed
H.E. Construction
RN Dogra Block, Top Floor, Const. Div PGIMER CHD
Providing and laying of pipeline for Flow Storm Water around backside of ANSC to Patiala Ki Rao and treated Spillover waste of STP/ETP to the nearest MC Manhole Point, PGIMER, Chandigarh
2026_PGIME_897586_1
PGI/Engg./Const./2026/255
Open Tender
Civil Works
90 days
PGI, Sector 12
Please refer Tender documents.
2 documents required · 2 mandatory
₹0
₹2.0 L
Yes
11 Apr 2026
7 Feb 2026
24 Feb 2026
7 Feb 2026
23 Feb 2026
7 Feb 2026
Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, for all lift, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.
All kinds of soil
Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 and for all lift.
Excavating trenches by mechinical / manual means of required width for pipes, cables, etc including excavation for sockets, and dressing of sides, ramming of bottoms, for all depth, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20 cm in depth, including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within a lead of 50 m:
All kinds of soil
Pipes, cables etc. exceeding 80 mm dia. but not exceeding 300 mm dia
Pipes, cables etc. exceeding 300 mm dia but not exceeding 600 mm
CONCRETE WORK
Providing and laying in position excluding cement concrete of level: specified grade the cost of centering and shuttering - All work up to plinth
1:4:8 (1 Cement : 4 coarse sand (zone-Ill) derived from natural sources: 8 graded stone aggregate 40 mm nominal size derived from natural sources)
Centering and shuttering including strutting, propping etc. and removal of form work for:
Foundations, footings, bases for columns
Dismantling manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge :
Water bound macadam road
bituminous road
Preparation and consolidation of sub grade with power road roller of 8 to 12 tonne capacity after excavating earth to an average of 22.5 cm depth, dressing to camber and consolidating with road roller including making good the undulations etc. and re-rolling the sub grade and disposal of surplus earthwith lead upto 50 metres.
Laying, spreading and compacting stone aggregate of specified sizes to WBM specifications in uniform thickness, hand picking, rolling with 3 wheeled road/vibratory roller 8-10 tonne capacity in stages to proper grade and camber, applying and brooming requisite type of screening / binding material to fill up interstices of coarse aggregate, watering and compacting to the required density .
Providing and laying Bituminous concrete using crushed stone aggregates of specified grading, premixed with bituminous binder and filler, transporting the hot mix to work site by tippers, laying with paver finisher equiped with electronic sensor to the required grade, level and alignment and rolling with smooth wheeled, vibratory and tandem rollers to achieve the desired compaction and density as per specification, complete and as per directions of Engineer-in-Charge.
40/50 mm compacted thickness with bitumen of grade VG-30 @ 5.5% (percentage by weight of total mix) and lime filler @ 3% (percentage by weight of Aggregate) prepared in Batch Type Hot Mix Plant of 100-120 TPH capacity.
DRAINAGE SYSTEM
Providing and laying C.C. pavement of mix M-25 with ready mixed concrete from batching plant. The ready mixed concrete shall be laid and finished with screed board vibrator , vacuum dewatering process and finally finished by floating, brooming with wire brush etc. complete as per specifications and directions of Engineer-in-charge. (The panel shuttering work shall be paid for separately). (Note:- Cement content considered in this item is @ 330 kg/cum. Excess/ less cement used as per design mix is payable/ recoverable separately).
Providing and laying non-pressure NP2 class (light duty) R.C.C. pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete :
600 mm dia. R.C.C. pipe
Constructing brick masonry circular manhole 1.52 m internal dia at bottom and 0.56 m dia at top in cement mortar 1:4 (1 cement : 4 coarse sand) inside cement plaster 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with a floating coat of neat cement, foundation concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size) and making necessary channel in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) finished with a floating coat of neat cement, all complete as per standard design :
2.30 m deep with SFRC Cover and frame (heavy duty HD- 20 grade designation) 560 mm internal diameter conforming to I.S. 12592, total weight of cover and frame to be not less than 182 kg. fixed in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) including centering, shuttering all complete. (Excavation, foot rests and 12 mm thick cement plaster at the external surface shall be paid for separately) :
With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
Providing orange colour safety foot rest of minimum 6 mm thick plastic encapsulated as per IS : 10910, on 12 mm dia steel bar conforming to IS: 1786, having minimum cross section as 23 mmx25 mm and over all minimum length 263 mm and width as 165 mm with minimum 112 mm space between protruded legs having 2 mm tread on top surface by ribbing or chequering besides necessary and adequate anchoring projections on tail length on 138 mm as per standard drawing and suitable to with stand the bend test and chemical resistance test as per specifications and having manufacture’s permanent identification mark to be visible even after fixing, including fixing in manholes with 30x20x15 cm cement concrete block 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) complete as per design.
Making connection of drain or sewer line with existing manhole including breaking into and making good the walls, floors with cement concrete 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) cement plastered on both sides with cement mortar 1:3 (1 cement : 3 coarse sand), finished with a floating coat of neat cement and making necessary channels for the drain etc. complete :
For pipes 350 to 450 mm diameter
Constructing brick masonry road gully chamber 50x45x60 cm with bricks in cement mortar 1:4 (1 cement : 4 coarse sand) including 500x450 mm pre-cast R.C.C. horizontal grating with frame complete as per standard design :
With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
Providing and Installation of HDPE for on grade gravity sewer including preparing and setting up the plant and equipment, preparing new pipe- work material, making of entry and exit pits upto 3 meter depth, installing new pipe- work and commissioning system or making the system ready for commissioning back the new pipe-work on the designed bore path align- ment, proper disposal of drilling fluid and back fill of site after completion. HDPE Pipes btween 255mm to 335mm Outer Dia: Mixed Strata (Dia not less than 300mm, PN6, PE100)of approved make
Add difference of Water Charges @ 0.50%
Please Enable Macros to View BoQ information
stage.html
html • 0.03 MB
techsummary_943469.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 18.16 MB
BOQ_943469.xls
BOQ • 0.32 MB
Download all tender documents and submit your bid