Tender Value
₹29 L
EMD Value
₹58,000
Closing Date
29 Jun 2020, 6:00 pmClosed
GE JAMMU
GE JAMMU PIN-180003 C/O 56APO
CERTAIN PETTY REPAIRS TO E/M SERVICES TO VARIOUS BLDGS AND REPAIR/MAINTENANCE OF ELECTRIC GEYSERS, REPAIR / RENEWAL OF EARTHING SYSTEMS AND ALLIED ITEMS AT MIRAN SAHIB UNDER GE JAMMU.
2020_MES_348725_1
GEJC-08/2020-21
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE JAMMU
Class D Category b(i)
8 documents required · 8 mandatory
₹500
GE JAMMU
₹58,000
Yes
31 Aug 2020
1 Jun 2020
1 Jul 2020
1 Jun 2020
29 Jun 2020
15 Jun 2020
Amount
Taking down old unsv copper/aluminium point wiring concealed / batten (light, fan, socket or power) complete, including fixture and fittings such as switches,sockets,ceiling roses,bell push,bell electric,lamp holder,bulk head fitting, pendants, regulators, sockets, light fitting and any type switch board wooden/iron,round block etc removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc
Taking down old and unserviceable submain wiring any size of two core & incldung earth wire complete including batten/ conduit and make good the disturbed surface to match the existing surface, all as directed by Engr-in-charge.
Taking down old and unserviceable, distribution board any type including , MCBs etc after removing all connection and make good the disturbed surface all as directed by Engr-in-charge.
Taking down unserviceable MCCBS,MCBs,SP,SPN,TPN and isolator from the existing DBs complete all as specified and as directed by Engr-in-Charge.
M&L for point wiring for one light/fan/call bell point controlled by one 5 Amp switch with 1.5 Sqmm single core multistranded copper conductor FRLSH, PVC insulated (unsheathed) heavy duty cable including continuous earth wire of size 1.5 sqmm copper conductor multistrand FRLSH, PVC insulated (unsheathed) drawn into existing concealed PVC rigid/steel conduit & into existing CI/pressed steel terminal boxes including 3.00mm thick hylam brand IS-2036 marked, laminated sheet cover for mounting switches, sockets, fan regulators etc complete all as specified. Note : (a) wiring shall be done by using proper colour coding (b) Earth wire shall be of green colour (c) On RCC roof/celing PVC conduit shall be provided on surface with proper fixing clips all as directed by Engr-in-Charge.
All as per item No 5 here in above but 5 Amp socket outlet on same board
All as per item No 5 here in above but socket outlet 5 Amps independent board complete all as directed by Engr-in-Charge.
All as per Item No 5 here in above but for one 3 pin socket outlet 15 Amps on Independent board with cables 2.5 sqmm size.
M&L for point wiring for one light/fan/call bell point controlled by one 5 Amp switch with 1.5 Sqmm single core multistranded copper conductor FRLSH, PVC insulated (unsheathed) heavy duty cable including continuous earth wire of size 1.5 sqmm copper conductor multistrand FRLS, PVC insulated (unsheathed) drawn into an including new concealed PVC rigid/steel conduit ISI marked terminated into CI/pressed steel terminal boxes including 3.00mm thick hylam brand IS-2036 marked, laminated sheet cover for mounting switches, sockets, fan regulators etc complete all as specified. Note : (a) wiring shall be done by using proper colour coding (b) Earth wire shall be of green colour (c) On RCC roof/celing PVC conduit shall be provided on surface with proper fixing clips all as directed by Engr-in-Charge.
All as per item No 9 here in above but 5 Amp socket outlet on same board
All as per item No 9 here in above socket outlet 5 Amps independent board complete all as directed by Engr-in-Charge.
All as per Item No 9 here in above but for one 3 pin socket outlet 15 Amps on Independent board with cables 2.5 sqmm size.
All as per item No 9 here in above but drawn through an including new surface conduit PVC rigid non metalic conduit 20 mm dia for socket outlet 5 amp independent board complete with new pressed steel terminal boxes and hylum sheet cover
All as per item No 12 here in before but drawn through an including new surface conduit PVC rigid non metalic conduit 20 mm dia for socket outlet 15 amp independent board complete with new pressed steel terminal boxes and hylum sheet cover
M&L for replacement distribution board sheet steel phosphatised powder coated for MCB with copper bus bar and neutral link earthing stud SPN 12 way 240 volts double door complete all as directed by Engr-in-Charge.
M&L for replacement distribution board sheet steel phosphatised powder coated for MCB with copper bus bar and neutral link earthing stud SPN 8 way 240 volts double door complete all as directed by Engr-in-Charge.
M&L for replacement distribution board sheet steel phosphatised powder coated for MCB with copper bus bar and neutral link earthing stud SPN 4 way 240 volts double door complete all as directed by Engr-in-Charge.
M&L distribution board double door sheet steel phosphatised powder painted for MCB/DB with copper bus bar and neutral link earthing stud TPN 4 way 415 volts doubled door.
S&F in replacement TP & N vertical load line double door DB with 200 Amps bus bar, 415 Volt sheet metal enclouser suitable for G frame MCCB, 4 way
S&F in replacement MCCB 4 pole, 415 Volt fixed thermal and fixed maganatic setting of cap 125 Amps 10KA
S&F in replacement Isolator 4 Pole, TPN 415 volts, 100 Amps rating with rupturring cap 10 KA B Series, complete all as specified .
S&F in replacement for MCB TP&N 63 Amps 415 Volts. 'B' series rupturring capacity 10 KA Complete all as directed by Engr-in-Charge
S&F in replacement for MCB SP 6 to 32 Amps,240 Volt B Series
S&F in replacement for MCB SPN 32 Amps 240 Volts, 'B' series complete all as specified
S&F in replacement for MCB SPN 40 Amps 240 Volts, 'B' series complete all as specified
S&F in replacement for MCB SPN 63 Amps 240 Volts, 'B' series complete all as specified
S&F in replacement for switch piano, flush type single pole one way 5Amp, 240 volts all as specified .
S&F in replacement socket outlet 5 amp/5 pin flush type complete all as directed.
S&F in replacement Switch socket outlet combined 5 pin 5 amp flush type , 240 volts all as specified
S&F in replacement Switch socket outlet combined 2 in 1 , 3 pin 5 amp and `15 amp flush type , 240 volts all as specified
S&F socket outlet 15 Amps, 240 Volts, 6 pin flush type complete all as specified.
S&F for switch piano, flush type single pole one way 15 Amps, 240 volts all as specified .
S & F for bell push , flush type single pole , 5Amp, 240 volts all as specified .
S&F Ceiling Rose 3 terminal surface type Complete all as directed.
S&F in replacement PVC box (gang box) surface mounted heavy duty 3 way complete with socket outlet 2 in 1 , 6 pin 5 amp 240 volt alongwith switch piano 5amp complete all as specified
S&F in replacement PVC box (gang box) surface mounted heavy duty 3 way complete with socket outlet 2 in 1 , 6 pin 15 amp 240 volt alongwith switch piano 15amp complete all as specified
M& L in replacement for Lamp holder , insulated body , with back plate suitable for batten fittings Complete all as directed.
M& L in replacement Self ballast LED retrofit Lamp with PVC body and PC Diffuser 9 watt 230 Volt 6500K Complete all as directed.
S&F in replacement new generation energy saving ,wall mounted LED Tube light batten fittings , extruded aluminum heat sink provided for efficient heat dissipation & integrated electronic driver 20 Watt LED 6500K (4' ft long ) with LED rod 20 watt, 230 Volts 50 Hz.
S&F in replacement new generation energy saving, wall mounted LED Tube light batten fittings , extruded aluminum heat sink provided for efficient heat dissipation & integrated electronic driver 14 Watt LED 6500K (2 ft long ) with LED rod 14 watt, 230 Volts 50 Hz Complete all as directed.
S&F in replacement bulk head luminaries IP65 with opal diffuser 10 watt, 230 Volts LED type complete all as directed Engr-in-Charge.
S&F in replacement for replacement of LED street light fittng of cap 25 watt complete all as directed by Engr-in-Charge.
S&F in replacement recess mounting Energy efficient LED light bottom opening panel duly powder coated CRCA Steel housing IP 65 High quality polycarbonte body & aluminium plate heat sink, high quality diffuser, separate HPF driver suitable ceiling of 2'x2' complete all as specified and as directed.
S&F in replacement Stepped type electronic fan regulator flush type on the existing phenolic laminated sheet.
S&F in replacement Calling bell Ding Dong/buzzer AC 230 Volts, single pole.
M&L in replacement for Sub main wiring with proper colour coding , insulated , unsheathed , multistranded ,copper conductor FRLSH, cable of 2 run 6 Sqrmm for phase and neutral and one run of 4.0 Sqrmm for earth wire unsheathed , miltistranded , copper conductor FRLSH, drawn through rigid PVC concealed conduit fixed on wall. Two runs of cable for phase/neutral and one run of cable for earth will be measured and paid as one unit length. Note : Wiring shall be done in proper colour coding.
M&L in replacement for Sub main wiring with proper colour coding , insulated , unsheathed , multistranded ,copper conductor FRLSH, cable of 2 run 4 Sqrmm for phase and neutral and one run of 2.5 Sqrmm for earth wire unsheathed , miltistranded , copper conductor FRLSH, drawn through rigid PVC concealed conduit fixed on wall. Two runs of cable for phase/neutral and one run of cable for earth will be measured and paid as one unit length. Note : Wiring shall be done in proper colour coding.
M&L for Earthing complete with galvanised steel earth plate electrode 60x60cmx6.3mm thick, buried directly in ground (earth pit not less than 2.25 meters deep below ground level) with top edge of the plate not less than 1.5 meters below normal ground level, connected to galvanised earth lead wire 4.0mm dia by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in Electrical plate No 3 connected to earthing test point all as specified or indicated including testing on completion.
S&F in replacement of electronic ballast in ABS housing with lead in wires suitable for FTL fittings 1x28 watt, 240 Volts complete all as specified and directed by Engr-in-Charge.
S&F in replacement of electronic ballast in ABS housing with lead in wires suitable for FTL fittings 1x36 watt, 240 Volts complete all as specified and directed by Engr-in-Charge.
S&F in replacement LED tube rod of cap 18 watt, T8 240 volts suitable for existing 36 watt fittings complete all as directed by Engr-in-Charge.
S&F in replacement LED tube rod of cap 18 watt, T5 240 volts suitable for existing 28 watt fittings complete all as directed by Engr-in-Charge.
S&F in replacement Flueroscent Tube Road (FTL) of cap 28, watt, T5 240 volts suitable for existing 28 watt fittings complete all as directed by Engr-in-Charge.
S&F in replacement Flueroscent Tube Road (FTL) of cap 36, watt, T5 240 volts suitable for existing 36 watt fittings complete all as directed by Engr-in-Charge.
Supply and fixing in replacement of SK light fitting with energy efficient LED wall bracket up/down light fitting with B-22 d with clear glass cover with LED lamp 9 watt complete all as specified and directed.
M&L for fan regulator 1 moudle stepped type (electronic) for 1200/1400mm sweep AC ceiling fan, complete all as specified by Engr-in-Charge.
M&L for capacitor 2.5 mfd 220 Volts AC 50 Hz all as specified and as directed by the Engr-in-Charge.
M&L for capacitor 4.0 mfd 220 Volts AC 50 Hz all as specified and as directed by the Engr-in-Charge.
M&L for single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB 32 Amps 240 Volts complete all as sepecified and directed. Make: Havells/Anchor/L&T
M&L for round sheet heavy duty for fixing on junctionboxes/fitting/fixtrures as required at site incl suitable size machine screws as required complete all as specified and directed.
M&L for LED bulb 12 watt retrofit type 6500 k complete all as specified and as directed by Engr-in-Charge. Make : C&S, Wipro, Havells, Syska
M&L for replacement of unserviceable flexible wire 2 core of size 1.0 sqmm with PVC insulated multistranded copper conductor twisted flexible wire for working voltage 1100 volts all as specified and directed. Make: Havells/Anchor/Finolex
M&L for replacement of unserviceable wire of size 1.5 sqmm single core FRLSH insulated multistranded copper conductor for working voltage 1100 volts sqmm Make: Havells/Anchor/Finolex
M&L for replacement of unserviceable wire of size 2.5 sqmm single core FRLSH insulated multistranded copper conductor for working voltage 1100 volts sqmm Make: Havells/Anchor/Finolex
M&L for replacement of unserviceable wire of size 4.0 sqmm single core FRLSH insulated multistranded copper conductor for working voltage 1100 volts sqmm Make: Havells/Anchor/Finolex
M&L for replacement of unserviceable wire of size 6.0 sqmm single core FRLSH insulated multistranded copper conductor for working voltage 1100 volts sqmm Make: Havells/Anchor/Finolex
M&L for pvc non matalic rigid conduit of size 20mm complete all as directed by Engr-in-Charge
M&L for machine screw of size 25mm long (packing of 144 screw)
All as per Srl item No 68 here-in- before, but of size 40 mm long
Taking down and strip opening to geyser of any make and cap 25/35/50 ltrs including disconnection of all water pipe connection and taking out water inlet/ outlet assly, removing glass wool ,the inner tank, descaling the assembly and tank , detecting the leakage, welding / brazing the defected part , repacking the glass wool and refixing the same after making it funcional including replacement of worn out nuts bolts washer etc complete all as specified and directed. Note: Cost of material and labour for providing new items shall be measured under relevant items of sch A.
M&L for replacement of water inlet and outlet geyser assembly of existing make as required at site with rubber gasket suitable for geyser of 25/35 ltrs capacity electric driven water storage heater with provn of housing for thermostat assembly, heating element fixing arrangement nuts bolts and washers etc. complete all as specified and directed .
M&L for replacement of water inlet and outlet assembly of existing make as required at site with rubber gasket suitable for geyser of 50 ltrs capacity electric driven water storage heater with provn of housing for thermostat assembly, heating element fixing arrangement nuts bolts and washers etc. complete all as specified and directed .
M&L for replacement thermostat , switch electric water heater storage type of cap 25/ 50 ltr, 230 volts of existing make of geyser.
M&L for replacement heating element with triangular base/round base, single phase, 230 volt, cap 2 KW of existing make.
M&L for replacement heating element with traingular/round base, single phase, 230 volt, cap 1.5 KW of existing make.
M&L for replacement pressure release valve conforming to relevant IS 15mm bore suitable for fixing with GI pipe/tubing 15mm bore complete all as specified and directed.
M&L for replacement of heavy duty PVC connection (For Hot Water) nylon threaded 450mm large (18”) 15mm bore including brass nuts, rubber washers complete on both ends.
All as per Srl item No 77 here-in- before, but for cold water
M&L for replacement of indicator lamps round/rectangular type 230 volt AC suitable for geyser of any capacity including providing electric connections complete all as specified & directed.
M&L for replacement water storage inner tank of stainless steel heavy duty confirms to ISI 25/35 ltrs capacity geyser, with provn for fixing 15mm dia galvanized air release valve all as specified and directed.
M&L for replacement water storage inner tank of stainless steel heavy duty confirms to ISI 50 ltrs capacity geyser, with provn for fixing 15mm dia galvanized air release valve all as specified and directed.
Supply and fixing in replacement plug top 15 Amps 3 pins all as specified and directed.
Material and labour for painting of geyser of cap 25/35/50 ltr complete with superior quality synthetic enamel white paint by spray painting after scraping old paint and making surface clean all as specified and directed.
Material and labour for replacement Non Return valve 15 mm dia complete all as specified and directed.
Material and labour for replacement split bottom cover (two pieces) suitable for 25 to 50 lts Geysers complete with fixing arrangement etc as required at site.
Material and labour for replacement rubber Gasket heavy duty of water inlet outlet assembly suitable for 25 ltrs capacity Geyser.
Material and labour for replacement outer shell suitable for 25/35 ltr geyser made out of GI sheet heavy duly confirming to ISI suitable for existing make of geyser complete factory manufactured painted.
Material and labour for replacement outer shell suitable for 50 ltr geyser made out of GI sheet heavy duly confirming to ISI suitable for existing make of geyser complete factory manufactured painted.
S&F in replacement glass wool suitable for geysers
Repair/maintenance / servicing to solar water heater system having a capacity 200 to 500 LPD complete with descaling/cleaning to flat plate collector plate,solar heater water tanks, toughned solar glass panels, welding/breazing to solar tanks, Repair/rectification of leakage in inlet/outlet water tubing GI, checking and repair to electric system,Repair of water make up tank and make the system function cable after repair/servicing and rectification the of fault complete with and including repacement of minor spare parts. (Note: Spare Shall be measured and paid sepratly)
Supply only union medium grade 25 mm dia
Supply only union medium grade 20 mm dia
Supply only Rubber hose pipe with MS clamp of suitable size
Supply only Gun metal gate/glove valve 20 mm dia
Supply only Rubber gasket of toughned glass
Supply only Painting to steel structure base frame
Supply only float valve PVC 20 mm dia
Material and labour for Electrical heating element threaded type 3 KW single phase suitable for solar water heater complete all as specified and directed.
M & L for toughned Collector glass of size 1.5M x 1.0 Mtr complete all as specified and directed confirming to ISI.
M & L for fastners 80-100 mm long for fixing of geyser of capacity up to 50 ltrs including grouting completed works in wall as per site requirement with the floor complete all as specified and directed.
S&F in replacement Chromium plated CP Bib cock 15 mm Dia Conforming to ISI.
S&F in replacement Gun metal glove/gate valve 15 mm Dia internal threaded with iron wheel head Conforming to ISI.
Supply and fixing in replacement of UNSV bolt 16 mm dia X6'' long fully threaded with counted head nuts and washer heavy duty conforming to ISI for MS column pipe/CI flenged pipe all as specified and directed.
M & L for replacement of tubing GI "MG" with all fittings laid in floor or trenches including taking out old UNSV pipe of size 15 mm dia complete all as specified and directed
All as per ser No 48 here in before but using galvanised iron strip of 32X6 mm as earthing lead
S&F in replacement test point terminal block made out of GI Strip 32 X 6 mm as per site requirement complete with fixing MS clamp nut bolt
M&L for replacement of UNSV aluminium earth strip size 25X3 mm thick complete with replacement of MS saddle/Clamp,fixing screw etc for roof conductor and down conductor above ground and on wall all as specified and directed.
All as per item No 100 here in before but 32X6 mm buried in ground and fixed on wall.
S&F in replacement GI tubing light grade complete with fitting and fixed to wall/ceilling floor 40 mm dia
M&L for replacement of Air termination single pointed aluminium rod 12 mm dia and 300 mm long
Labour for repair to existing unsv/Loose/Hanging GI or aluminium earth strip fix on and around the RCC reservoir complete with an including MS saddle/clamps,nut bolt,screw as per site requirement and fix the strip properly with RCC reservoir wall.(Note: Rates are deemed to be including charges for hiring T&P and Life insurance of person deputed at site.)
S&F in replacement Gun metal glove/gate valve 15 mm Dia internal threaded with iron wheel head Conforming to ISI.
M&L for cutting to existing GI pipe line of any size in position for addition alteration/for branch connection or insertion of tee complete with including GI fittings for jointing branch connection,threading,earthwork as per site requirement all as specified and directed.
M&L for replacement of Sintex tank double layer 200 Ltr complete with float valve all as specified and directed.
Sarbat Construction Co
M/S S K Electricals Regd
M/S Bali Agencies
Bidder Name
M/S S K Electricals Regd
Sarbat Construction Co
M/S Bali Agencies
M/s Sahib Construction and engineers
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .