| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹20.1 LAccepted-AOC | L1 | Accepted-AOC Lowest Bidder | |
| 2 | L2₹23.8 L+₹3.3 L (15.9%)Rejected-Finance 11 71 KAVERI PATH MANSAROVAR JAIPUR | JAIPUR | JAIPUR | RAJASTHAN | L2 | Rejected-Finance Not Lowest Bidder | |
| 3 | L3₹24.4 L+₹3.9 L (18.8%)Rejected-Finance | L3 | Rejected-Finance Not Lowest Bidder | |
| 4 | L4₹24.8 L+₹4.3 L (20.8%)Rejected-Finance VPO MAJOD TEHSIL HANSI DISTRICT HISAR 125049 HARYANA | HISAR | HISAR | HARYANA | 125049 | L4 | Rejected-Finance Not Lowest Bidder | |
| 5 | L5₹25.5 L+₹4.9 L (24.0%)Rejected-Finance | L5 | Rejected-Finance Not Lowest Bidder |
Tender Value
₹35 L
EMD Value
₹70,000
Closing Date
5 Oct 2024, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE HISAR
GE HISAR
CA NO GE(H)-42/2024-25 REPAIRS / REPLACEMENT TO FLOOR, WALL, FINISHES, JOINERY AND ALLIED WORKS OF OTM ACCN ZONE A AND B IN THE AOR OF AGE B/R-I UNDER GE HISAR AT HISAR MIL STN
2024_MES_672684_1
CA NO GE(H)-42/2024-25
Open Tender
Civil Works
Item Rate
300 days
Hisar
AS PER NIT
6 documents required · 6 mandatory
₹500
GE HISAR
₹70,000
Yes
2 Dec 2024
6 Sept 2024
7 Oct 2024
6 Sept 2024
5 Oct 2024
21 Sept 2024
Amount
Dismantling of cast iron pipes of any size of bore as in soil, waste or vent pipe including removal of cement joint fixed to wall or laid in floor complete all as specified and directed .
Demolition of cement concrete (un-reinforced) in ground floor and paving not exc 15 cm thickness (below or above ground level.) & removing unserviceable materials in low laying area, complete, all as directed.
Demolition of brick/stone masonry built in cement/lime mortar of any mix and stacking serviceable stones aside for reuse & removing unserviceable materials in low laying area, complete, all as directed.
Taking down cement plaster or cement lime plaster on PCC/stone surface/brick surfaces including raking out joints hacking for key scrubbing down with water etc all as directed.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing) and rubbish off the premises.
Hacking out old broken glass any thickness, size, quality or description from metal frame including punching or drilling out old glazing pins/spring clips complete all as specified and as directed.
M&L for treatment of sunken floor slab compraises of the following specifications and all as specified :- (i) M&L for cleaning the sunken/lowered portion of RCC slab surface (including vertical surfaces upto finished floor level) of floors by wire brush, chisel out any mortar sticking to the surface and brooming completely and providing 40mm thick avgerage PCC 1:2:4 type B-0 using 12.5mm graded aggregate as in padding concrete to achieve proper slope including cutting holes in bricks or RCC wall for providing spout 50mm bore GI pipe medium grade of length 0.50m and fixed all as specified. (ii) M&L for providing rendering of uneven surfaces of vertical sunken with 6mm thick CM 1:4 mixed with integral water proofing compound @ 3% by wt of cement consumed. (iii) M&L for applying two coats of polymer modified cementious water proof coating (Sika / Fosroc / STP / Asian Paint )as per manufacturers instruction to bottom and vertical sides up to finished floor level and 100mm aove FFL , the thickness of two layer shall be 1mm and when the second layer is still sticky, coarse sand spray shall be carried for the vertical and bottom surface of the sunken portion all as specified and directed. (iv) M&L for providing plaster to the bottom and sides up to FFL with minimum 20mm thick CM 1:4 mixed with integral water proofing compound 3% by wt of cement consumed as per manufacturer's specification including rounding of corners and junctions sloping towards spout. ote :-(i) All junctions points of side wall where CI/GI pipes are passing through shall be sealed with epoxy putty. (iii) After drying putty, wash the slab and sides of sunken portion with water and make it clear and clean. (iii) All pipes laid in sunken portion shall be covered with 50mm thick PCC 1:3:6 all round after painting with anticorrosive paint and cost is deemed shall be included in quoted rates. (iv) Cost of WPC shall deemed to be included in quoted rates. (v) Test the water proofed area (ponding test) by filling water for at least 72 hours and tested for leakage seepage to the entire satisfaction of GE. Test shall be done in presence of reps of Engineer-in-charge and record for each sunken slab shall be maintained. (vi) The treatment shall be carried out in presence of Engineer-in-charge and tested. Cost of testing is inclued in the rates quoted above. (vii) For Payment purpose, the Plan area of Sunken floor shall be taken into account.
S&F 100mm bore pipe cast iron sand pipes for soil and waste and vent pipes in any length with our without cars , with cement joints laid in trenches or in floors complete all as specified.
S&F 75mm bore pipe cast iron sand pipes for soil and waste and vent pipes in any length with our without cars , with cement joints laid in trenches or in floors or fixed to wall complete all as specified.
S&F 100mm bore cast iron bends (any radius), diminishing pieces or tapers (larger bore measured) complete all as specified & as directed.
S&F 75mm bore cast iron bends (any radius), diminishing pieces or tapers (larger bore measured) complete all as specified & as directed.
S&F in repairs 100mm bore cast iron branch piece, single (equal or unequal), ordinary or inverted (spigot or socket type) or with parallel branches with oval access door.
S&F in repairs 75mm bore cast iron branch piece, single (equal or unequal), ordinary or inverted (spigot or socket type) or with parallel branches with oval access door.
S&F 100mm bore cast iron 'P' or 'S' trap complete all as specified & as directed.
S&F cast iron floor trap of 100 mm bore, with grating including jointing to waste pipe, fixed in cement concrete type B1 (1:2:4), complete all as specified & as directed.
S&F cast iron floor trap of 75 mm bore, with grating including jointing to waste pipe, fixed in cement concrete type B1 (1:2:4), complete all as specified & as directed.
M&L PCC 1:5:10 type E2 using 40 mm graded stone aggregate insunken portion, filling and mass concrete complete all as specified & as directed..
M&L for non skid ceramic jointfree tiles (coloured) premium quality, 7 to 8mm thick, area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, as in floors, set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles laid over & including 15mm thick screed bed in cement & sand mortar 1:6 complete all as specified and as directed.
M&L for non skid ceramic jointless tiles (coloured) 1st quality, 7 to 8mm thick, area of each tile exceeding 0.18 sqm but not exceeding 0.36 sqm, as in floors, set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles laid over & including 15mm thick screed bed in cement & sand mortar 1:6 complete all as specified and as directed.
M&L for glazed ceramic tiles (coloured)1st quality, 300mm x 450mm x 7mm thick, on vertical surfaces such as dado, skirting etc., set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles laid over & including 10mm thick rendering (as screed bed) in cement & sand mortar 1:4 complete all as specified and as directed.
M&L for vitrified ceramic tiles 1st quality, 10mm thick (square/rectangular), polished, coloured (light shade as approved), area of each tile not exceeding 0.36 sqm, in floors etc, set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles laid over & including 15mm thick screed bed in cement & sand mortar 1:6 complete all as specified and directed.
M&L for vitrified ceramic tiles 1st quality, 10mm thick (square/rectangular), polished, coloured (light shade as approved), area of each tile not exceeding 0.36 sqm, on vertical surfaces such as dado, skirting etc., set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles laid over & including 10mm thick screed bed in cement & sand mortar 1:4 complete all as specified and as directed.
M&L for machine cut Kota stone slab flooring 18 to 20mm thick laid over & including screed bed or bedding layer of 15mm thick in CM 1:6 and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and mirror polishing complete all as specified. Note : - Kota stone shall be of size 550mm x 550mm (minimum) when brought at site
M&L for machine cut Kota stone slab 18-20mm thick in riser of steps, skirting, dado and pillar, laid over cement screed and jointed with grey cement slurry mixed with pigment to match the shade of slab including rubbing and mirror polishing laid over & including 10mm thick rendering (as screed bed) in cement & sand mortar 1:4 complete all as specified and as directed.
M&L for factory made chequered cement concrete coloured tiles, glossy finish, 25cm x 25cm x 25mm thick, set, jointed and pointed in neat cement slurry in floors with grey cement & pigment, laid over & including 20mm thick screed bed in cement & sand mortar 1:4, complete, all as specified & as directed.
M&L for 20mm thick Granite slab of approved shade, as in cooking platform shelves etc, bedded & jointed with grey cement slurry and pointed with white cement with admixture of pigment to match with shade of Granite stone including cutting, grinding and polishing (mirror polish i.e. full granite polish as per local trade practice) including required cutting to suit the size of oval type wash hand basin over & including 20mm thick screed bed in cement & sand mortar 1:4 complete all as specified and as directed.
All as per item No 26 above w/o screed bedding but fixing of urinal partitions, shelves, Corner shelves etc of any shape and size includind necessary cutting to required shape and sizes and rounding the external edges of stone complete all as specified and as directed.
S&F in repairs fancy type pillar tap, cast copper alloy with capstan heads, chromium plated, fancy type, screwed down high pressure, with or without lettered ‘Hot’ or ‘Cold’ with long screwed shanks & fly nuts, screwed for iron pipes of 15mm bore.
S&F in repairs Bib taps,cast copper alloy with crutch or butterfly handle, chromium plated, fancy type , screwed for iron pipe or for brass ferrule, for 15 mm bore GI pipe complete all as specified and directed.
S&F in repairs 15mm bore Angle valve, fancy type , chromium plated cast copper alloy screwed down, high pressure, with crutch or butterfly handle, screwed both ends of iron pipe or for union and fixed all as specified and directed
S&F in repairs 15mm bore Stop valve fancy type with long shank and cup (concealed type) of cast copper alloy chromium plated screwed down, high pressure with capstan heads, screwed both ends for iron pipe or for union and fixed complete all as specified and directed
S&F in repairs, PVC connection 450 mm long suitable for 15 mm bore GI pipe including PTMT nuts on both sides complete all as specified.
S&F in repairs stainless Grating 110 mm dia with waste hole complete all as directed.
S&F in repair brass chromium plated overhead shower rose 125mm dia round shape with swivel joints complete all as specified and directed.
S&F in repairs Jet Spray with 1 Meter PVC Tube (Stainless Steel) complete all as specified and as directed.
S&F in repairs 15mm bore, fancy type brass CP Hand Shower (Health Faucet) (ABS Body) with 8mm Dia, 1.2 Meter Long Flexible Tube & Wall Hook including making connection and fixed in position complete all as specified and as directed.
S&F in repairs Peg set of 06, steel chromium plated complete all as specified and as directed.
S&F in repairs vitreous china half stall urinal, , white with grating and union for discharge pipe includng providing and fixing plugs, bedding urinal against wall in CM (1:2), securing urinal to plugs with and including 60mm long brass screws complete with PVC flush pipe complete all as specified and as directed.
S&F in repairs vitreous china wash hand basin, white, flat back of size 550mm x 400mm x 185mm with & including a pair of cast iron brackets embedded in PCC 1:3:6 type C1 blocks of size 10x7.5x15cm, 32 mm dia PVC waste pipe and 32mm bore PTMT waste fitting with long screwed shanks and fly nuts, flange end bedded in red lead cement & other end fixed, (excluding tap, waste chain & plug), complete all as specified.
S&F in repairs vitreous china squatting pan (Orissa pattern) water closet (white) of size 580x440mm with integral foot rests, with PTMT 'P' or 'S' trap, including connection to trap and flushing pipe, antisyphonage pipe etc including provision of PCC (1:5:10) type E2 in filling, making good to floor, complete all as specified.
S&F in repairs vitreous china wash down water closet (Padestal pattern) White, including plastic water closet seat cover, white, closed pattern with flat bottom with mild steel chromium plated or aluminium hinging device and fixing with all joints including connection to drain or outgoing pipe and to flushing pipe, anti-syphonage pipe etc complete all as specified and as directed.
S&F in repairs PVC valveless symphonic action type low level flushing cistern (ISI marked) of 10 litre capacity including 32 mm dia PVC flush pipe connected to water closet with inlet, ball valve, float and handle complete all as specified
S&F in repairs Plastic water closet seat cover, white fancy type, closed pattern with flat bottom, and cover and mild steel chromium plated or aluminised hinging device.
S&F 3mm thick transparent polycarbonate solid sheet, in square/rectangular size, smooth surface, weather resistant, fine finish, bent and pressed including aluminium glazing clips, rubber beading and clear silicon or glazing with oil putty with putty or fixed with beads complete all as specified and directed
Taking up or down 15mm bore steel tubing and connection incl cleaning for refixing or removal to store
Taking up or down 20mm bore steel tubing and connection incl cleaning for refixing or removal to store
Taking up or down 32mm bore steel tubing and connection incl cleaning for refixing or removal to store
M&L for galvanized steel water tubing medium grade of 15mm bore with & including all fittings and fixed complete to walls and ceilings or laid in floors all as specified and directed
M&L for galvanized steel water tubing medium grade of 20mm bore with & including all fittings and fixed complete to walls and ceilings or laid in floors all as specified and directed
M&L for galvanized steel water tubing medium grade of 32mm bore with & including all fittings and fixed complete to walls and ceilings or laid in floors all as specified and directed
M&L for factory made 60mm thick machine pressed precast cement concrete coloured interlocking paver blocks glossy finish of Grade M-35 conforming to IS 15658-2006 of shape and size as directed with grey cement and pigment laid over & including 25mm thick sand cushioning, joints of blocks filled with dry sand and compacted with mechanical vibrator complete all as specified & directed.
M&L for Providing and laying at or near ground level factory made kerb stone of M-25 grade cement concrete in position to the required line, level and curvature, jointed with cement mortar 1:3 (1 cement: 3 coarse sand), including making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5 mm), including making drainage opening wherever required complete. complete, all as directed.
M&L for brick work with old size sub-class ‘B’ bricks, straight or curved on plan exc 6.00 metre mean radius, built in cement mortar 1:6 complete all as specified.
M&L brick work with subclass 'B' old size bricks, straight or curved on plan to any radius in half brick thick walls built in cement mortar 1:4 complete all as specified.
M&L for 50mm thick PCC 1:2:4 type B1 using 20mm graded crushed stone aggregate as in Floors laid in panels over neat cement slurry @3.0 kg per Sqm and finished even & smooth w/o using extra cementas in Basket ball court complete all as specified & as directed. Note: PCC shall be of RMC obtained from near by plant with perior permission of EIC.
Supply and fix plastic dividing strips 3mm thick and 38mm wide inserted and fixed in position confirm to design complete all as specified.
M & L for preparation of newly concreted surfaces of any description over 10cm width or girth not otherwise described and applying two coats of plastic enamel paint over a coat primer complete all as specified and as directed.
S&F Factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails. M.S. frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; Panelling of plain colour PVC sheet to be fitted in the M.S. frame welded / sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement, suppling & fixing in the frame at site as per specification & drawing complete all as specified & directed.
S&F for factory made Solid PVC Door Frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with M.S. Square tube, suppling & fixing in opening as per specification & drawing complete all as specified and directed.
Supply and fixing in repairs Stainless steel wire cloth, 0.56mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples complete all as specified.specified.
S&F stainless steel butt hinges of size 100mm medium weight, cold rolled mild steel ISI marked complete all as specified.
S&F 150mm long extruded aluminium alloy handles, fabricated type, anodised (ISI marked) complete all as specified.
S&F 150mm long aluminium anodized barrel tower bolts of extruded section (ISI marked) complete all as specified.
M&L rendering 5mm thick in cement mortar 1:3 on concrete surfaces in ceiling, finished even & smooth without using extra cement complete all as specified
Material and labour preparation of newly plastered/asbestos cement surfaces of ceilings & applying three coats of white wash complete all as specified.
M & L for rendering 15mm thick in cement mortar 1:6 on faces of brick work or concrete surfaces of walls, finished even and smooth without using extra cement complete all as specified
M&L for preparation of newly plastered surfaces of wall & applying two coats of oil bound distemper of approved shade/tint over a coat of primer on walls all as specified & as directed
M & L for rendering 15mm thick in cement mortar 1:4 on faces of brick work or concrete surfaces of walls, finished even and smooth without using extra cement including mixed with and including liquid water proofing compound @200 ML per 50 KG by weight of cement complete all as specified and directed.
M&L for preparation of new plastered surfaces of walls and applying two coats of cement base paint of approved shade/tint over a coat of alkali resistant primer of same make all as specified & as directed.
M&L for rough cast finish plaster by applying the under coat of cement and sand mortar 1:3 not less than 10 mm thick and while it is still in plastic state the roughcast mixture consisting of crushed stone or fine gravel aggregate (size between 6 to 12 mm depending on the texture required) mixed with coarse sand and cement in the ratio of 1: 1: 1 shall be applied and finished even complete .
Supply and fixing in replacement 500 Litre capacity Rotational moulded polyethylene water storage tanks (colour other than black as approved by Engineer-in-charge) triple layered (cylindrical vertical with closed top) ISI marked, hoisted & fixed in position & making necessary arrangements for fixing inlet, outlet & over flow pipe & provision of wash out pipe etc. complete as specified in SSR Part-I.
Supply and fixing in replacement 1000 Litre capacity Rotational moulded polyethylene water storage tanks (colour other than black as approved by Engineer-in-charge) triple layered (cylindrical vertical with closed top) ISI marked, hoisted & fixed in position & making necessary arrangements for fixing inlet, outlet & over flow pipe & provision of wash out pipe etc. complete as specified in SSR Part-I.
Supply and fixing in replacement 2000 Litre capacity Rotational moulded polyethylene water storage tanks (colour other than black as approved by Engineer-in-charge) triple layered (cylindrical vertical with closed top) ISI marked, hoisted & fixed in position & making necessary arrangements for fixing inlet, outlet & over flow pipe & provision of wash out pipe etc. complete as specified in SSR Part-I.
S&F float Ball valves, high pressure of PTMT with epoxy coated aluminium rod & high density plastic ball, screwed for iron pipe 20mm bore (minimum weight 210 gms) complete all as specified and as directed.
S&F float Ball valves, high pressure of PTMT with epoxy coated aluminium rod & high density plastic ball, screwed for iron pipe 15mm bore (minimum weight 142 gms) complete all as specified and as directed.
S&F in repairs Gun metal gate valve with iron wheel head, screwed both ends for iron pipe of 15mm bore
S&F in repairs Gun metal gate valve with iron wheel head, screwed both ends for iron pipe of 20mm bore
M&L for PCC 1:2:4 type B0 using 12.5mm graded crushed stone aggregate as in levelling course 25mm thick finished fair & even complete all as specified & as directed.
M&L for grinding, rubbing and mirror finish polishing to existing kota stone/mosaic floors/vertical surafces etc complete by mechanically by using different grits all as specified and directed.
M&L for 75mm thick PCC (1:4:8) type D2 using 40 mm graded crushed stone aggregate as in sub base, surface finished fair and even complete all as specified.
Dismantling wall and ceiling boards (fibre, pulp, insulation etc) or insulation boards / slabs / blankets any thickness, including cover fillets complete all as specified
S&F GI powder coated snap grid of sizes 605 mm x 605 mm frame work for false ceiling with main tee 32 x 24 x 1mm thick, cross Tee 26 x 24 x 1mm and wall angle 24 x 24 x 1mm thick, flange covered with PVC thin includng hangers 6mm dia GI (upto 1200mm length) adjusting level fixed to roof slabs by means of ceiling cleats made out of GI flat 40 x 3 mm size 60mm long and expansion hold fasteners 12.5mm dia 40mm long including Gypsum board 7-9mm thick duly finished surface (thin PVC layer on gypsum board as per maunfacturer's instructions) of size 600mmx600mm thick and the same shall be placed in snap grid as in false ceiling complete all as specified & directed.
S&F 5mm thick hollow PVC wall lining, single side prelaminated with flat or fancy patterned on laminated side, PVC sheet inclusive of fixing with screws or with solvent cement required at site on walls including necessary corner angles, filltes etc required at site complete all as specified and directed.
S&F 110mm bore PVC (SWR) pipes single socketed in any length with rubber ring joints / solvent cement joints fixed to walls with necessary MS / PVC clamps and necessary screwing complete all as specified.
Supply and fixing 75/110 mm bore PVC (SWR) bends any radius with access door complete all as specified.
Supply and fixing in repairs MS clamps for rain water pipe complete all as specified.
Balaji Construction Co. (BID ID -3117912)
Shiva Constructin Co. (BID ID -3116034)
VIKAS INFRASTRUCTURE (BID ID -3118255)
M/S RAJESH KUMAR & SONS (BID ID -3129947)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .