Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹42.7 LAccepted-AOC GUIJAN GAON WARD NO 3 C O RAJKHOWA HOUSE P O RANGAGORA DIST TINSUKIA ASSAM PIN 786147 | TINSUKIA | ASSAM | 786147 | L1 | Accepted-AOC LOWEST BIDDER | |
| 2 | L2₹43.7 L+₹47,059.40 (1.09%)Rejected-Finance AT ROAD TINSUKIA HIJUGURI BASH BARI P O HIJUGURI DIST TINSUKIA ASSAM PIN 786125 | TINSUKIA | ASSAM | 786125 | L2 | Rejected-Finance NOT BEING L1 | |
| 3 | L3₹44.3 L+₹1.1 L (2.60%)Rejected-Finance P O WEST SRIPURIA DIST TINSUKIA ASSAM PIN 786 145 | TINSUKIA | ASSAM | 786145 | L3 | Rejected-Finance NOT BEING L1 | |
| 4 | L4₹45.1 L+₹1.9 L (4.30%)Rejected-Finance | L4 | Rejected-Finance NOT BEING L1 | |
| 5 | L5₹45.3 L+₹2.1 L (4.91%)Rejected-Finance | L5 | Rejected-Finance NOT BEING L1 |
| Sl No | Description | Qty | Unit | Shree Trilok Electric Corporation L6 | AFTAB ENTERPRISES L5 | FREEZCON L4 | M H KHAN L8 | Construction House L3 | M/S. UDDUG CONSTRUCTION L1 | M/S R D CONSTRUCTION L2 | M/S A K ENTERPRISE L7 |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1.00 | Roughening surfaces of old concrete floor by picking, sweeping clean and washing down with water to remove dust, etc and brushing neat cement slurry with 3.0kg of cement per sq. meter complete all as specified and directed | 1,175 | Sqm | 51 ₹59,925 | 40 ₹47,000 | 52 ₹61,100 | 40 ₹47,000 | 45 ₹52,875 | 35 ₹41,125 Lowest | 38 ₹44,650 | 45 ₹52,875 |
| 2.00 | M&L for EPU anti-static flooring (Epoxy flooring) over existing PQC after proper cleaning of surface and applying low viscous epoxyy primer having resin and hardener mix and laid and applying epoxy resin based seif-smooth screed 3mm thick on the clean and dry surface having high abrasion resistance spread uniform thickness using self-adhesive copper tape and applying conductive primer coat and finally applying EPU based self-leveling top coat of Flex Hard EPU to yield as average thickness of 2mm complete all as specified and directed. | 1,175 | Sqm | 1,990 ₹23,38,250 Lowest | 2,160 ₹25,38,000 | 2,118 ₹24,88,650 | 2,378 ₹27,94,150 | 2,100 ₹24,67,500 | 2,050 ₹24,08,750 | 2,075 ₹24,38,125 | 2,330 ₹27,37,750 |
| 3.00 | M&L for preparing of old steel & iron surfaces of any description, not otherwise described, over 10cm width or girth and applying one coat of synthetic enamel paint complete all as specified and as directed. | 1,950 | Sqm | 115 ₹2,24,250 | 76 ₹1,48,200 | 80 ₹1,56,000 | 85 ₹1,65,750 | 73 ₹1,42,350 | 74 ₹1,44,300 | 72 ₹1,40,400 Lowest | 83 ₹1,61,850 |
| 4.00 | Removing old paint by paint removers or burning off by blow lamps and cleaning with scrapers, any number of coats, any width or girth and preparing of old steel & iron surfaces of any description, not otherwise described, over 10cm width or girth and applying two coats of synthetic enamel paint complete all as specified and as directed. | 311 | Sqm | 121 ₹37,631 Lowest | 233 ₹72,463 | 232 ₹72,152 | 252 ₹78,372 | 227 ₹70,597 | 218 ₹67,798 | 223 ₹69,353 | 246 ₹76,506 |
| 5.00 | Excavating in trenches n exc 1.5m wide and n exc 1.5m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10sqm on plan and n exc 1.5m in depth and getting out in soft/loose soil complete all as specified and directed. | 106.5 | Cum | 375 ₹39,937.5 Lowest | 380 ₹40,470 | 390 ₹41,535 | 444 ₹47,286 | 384 ₹40,896 | 383 ₹40,789.5 | 390 ₹41,535 | 435 ₹46,327.5 |
| 6.00 | Returning filling in with approved excavated soil including spreading, leveling, watering and well ramming in layers not exceeding 25cm thick complete all as specified and directed. | 84.5 | Cum | 155 ₹13,097.5 | 135 ₹11,407.5 Lowest | 140 ₹11,830 | 161 ₹13,604.5 | 138 ₹11,661 | 139 ₹11,745.5 | 143 ₹12,083.5 | 157 ₹13,266.5 |
| 7.00 | Removing excavated soils to a distance not exceeding 50 metres and depositing where directed at a level not exceeding. 1.5 metre above the starting point complete all as specified and directed. | 22 | Cum | 360 ₹7,920 | 330 ₹7,260 | 327 ₹7,194 | 371 ₹8,162 | 322 ₹7,084 | 320 ₹7,040 | 316 ₹6,952 Lowest | 363 ₹7,986 |
| 8.00 | Supply, laying, connection and testing, 50mm bore, steel water tubing, galvanised, medium grade conforming to IS 1239 (Part -1):2004 with all fittings conforming to IS 1239(Part -2):2011 and fixtures laid in trenches etc complete all as specified and as directed. | 100 | RM | 495 ₹49,500 | 436 ₹43,600 | 432 ₹43,200 | 488 ₹48,800 | 426 ₹42,600 | 421 ₹42,100 | 418 ₹41,800 Lowest | 478 ₹47,800 |
| 9.00 | Supply, laying, connection and testing, 40mm bore, steel water tubing, galvanised, medium grade conforming to IS 1239 (Part -1):2004 with all fittings conforming to IS 1239(Part -2):2011 and fixtures laid in trenches etc complete all as specified and as directed. | 280 | RM | 410 ₹1,14,800 | 410 ₹1,14,800 | 405 ₹1,13,400 | 459 ₹1,28,520 | 400 ₹1,12,000 | 396 ₹1,10,880 | 392 ₹1,09,760 Lowest | 449 ₹1,25,720 |
| 10.00 | Supply, laying, connection and testing, 25mm bore, steel water tubing, galvanised, medium grade conforming to IS 1239 (Part -1):2004 with all fittings conforming to IS 1239(Part -2):2011 and fixtures laid in trenches etc complete all as specified and as directed. | 260 | RM | 331 ₹86,060 | 198 ₹51,480 | 197 ₹51,220 | 213 ₹55,380 | 193 ₹50,180 | 184 ₹47,840 Lowest | 190 ₹49,400 | 208 ₹54,080 |
Tender Value
₹47.5 L
EMD Value
₹95,000
Closing Date
30 Oct 2025, 6:00 pmClosed
GE DINJAN
GE DINJAN, PANITOLA (PO), DIBRUGARH (DIST), ASSAM PIN-786183
SPL REPAIRS OF BADMINTON COURT AT A SECT AND SPL REPAIR TO EPOXY COATING (APPROXIMATELY 1000 SQM) OF BLDG NO T-05A, WATER SUPPLY PIPELINES OF BLDG NO T-05A AND T-06A (UTILITY HELICOPTER HANGARS) AT DINJAN MIL STN UNDER GE DINJAN
2025_MES_734824_1
C/8957/E8
Open Tender
Civil Works
Item Rate
180 days
DINJAN MIL STN
AS PER TENDER DOCUMENTS
10 documents required · 10 mandatory
₹500
GE DINJAN
₹95,000
Yes
24 Nov 2025
11 Oct 2025
6 Nov 2025
11 Oct 2025
30 Oct 2025
25 Oct 2025
Amount
Roughening surfaces of old concrete floor by picking, sweeping clean and washing down with water to remove dust, etc and brushing neat cement slurry with 3.0kg of cement per sq. meter complete all as specified and directed
M&L for EPU anti-static flooring (Epoxy flooring) over existing PQC after proper cleaning of surface and applying low viscous epoxyy primer having resin and hardener mix and laid and applying epoxy resin based seif-smooth screed 3mm thick on the clean and dry surface having high abrasion resistance spread uniform thickness using self-adhesive copper tape and applying conductive primer coat and finally applying EPU based self-leveling top coat of Flex Hard EPU to yield as average thickness of 2mm complete all as specified and directed.
M&L for preparing of old steel & iron surfaces of any description, not otherwise described, over 10cm width or girth and applying one coat of synthetic enamel paint complete all as specified and as directed.
Removing old paint by paint removers or burning off by blow lamps and cleaning with scrapers, any number of coats, any width or girth and preparing of old steel & iron surfaces of any description, not otherwise described, over 10cm width or girth and applying two coats of synthetic enamel paint complete all as specified and as directed.
Excavating in trenches n exc 1.5m wide and n exc 1.5m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10sqm on plan and n exc 1.5m in depth and getting out in soft/loose soil complete all as specified and directed.
Returning filling in with approved excavated soil including spreading, leveling, watering and well ramming in layers not exceeding 25cm thick complete all as specified and directed.
Removing excavated soils to a distance not exceeding 50 metres and depositing where directed at a level not exceeding. 1.5 metre above the starting point complete all as specified and directed.
Supply, laying, connection and testing, 50mm bore, steel water tubing, galvanised, medium grade conforming to IS 1239 (Part -1):2004 with all fittings conforming to IS 1239(Part -2):2011 and fixtures laid in trenches etc complete all as specified and as directed.
Supply, laying, connection and testing, 40mm bore, steel water tubing, galvanised, medium grade conforming to IS 1239 (Part -1):2004 with all fittings conforming to IS 1239(Part -2):2011 and fixtures laid in trenches etc complete all as specified and as directed.
Supply, laying, connection and testing, 25mm bore, steel water tubing, galvanised, medium grade conforming to IS 1239 (Part -1):2004 with all fittings conforming to IS 1239(Part -2):2011 and fixtures laid in trenches etc complete all as specified and as directed.
Supply, laying, connection and testing, 20mm bore, steel water tubing, galvanised, medium grade conforming to IS 1239 (Part -1):2004 with all fittings conforming to IS 1239(Part -2):2011 and fixtures laid in trenches etc complete all as specified and as directed.
Supply, laying, connection and testing, 15mm bore, steel water tubing, galvanised, medium grade conforming to IS 1239 (Part -1):2004 with all fittings conforming to IS 1239(Part -2):2011 and fixtures laid in trenches etc complete all as specified and as directed.
S&F for 2000 liters capacity rotational moulded polyethylene water storage tanks (cylindrical or vertical with closed top) as per IS 12701:1996, hoisted and fixed in position, connecting with existing pipes, including provn of necessary fittings for connection of overflow, drain out, inlet and outlet pipes all as specified in SSR Part I complete all as specified and directed.
Supply and fixing 15mm cromium plated Bib taps, cast copper alloy with crutch or butterfly handle, fancy type, screwed down, screwed for iron pipe or for brass ferrule and fixed, complete all as specified and directed.
M&L in repairs 20 mm dia stop valve cast copper alloy screwed down, high pressure with crutch or butterfly handle screwed both ends for iron pipe or for union complete all as specified and as directed.
M&L in repairs 40 mm dia stop valve cast copper alloy screwed down, high pressure with crutch or butterfly handle screwed both ends for iron pipe or for union complete all as specified and as directed.
S&F in repair bib tap standard of PTMT any colour high pressure screwed for iron pipe and fixed. (Minimum weight 15mm-90gms/20mm 125gms) complete all as specified and as directed.
Supply and fixing in repair Ball valves high pressure of PTMT 40 mm bore with epoxy coated Aluminium rod & high-density plastic ball screwed for iron pipe and fixed. (Minimum weight -455gms), screwed for iron pipe etc complete all as specified and directed.
Demolition of brickwork built in cement mortar including taking out roots vegetation if any at any position and removal from site, complete all as directed.
Demolition of cement concrete (un reinforced) in ground floors and paving n. exc. 15 cm thickness (below or above ground level) removing rubbish off the premises etc. complete all as directed
Excavating in post holes (or similar holes) each n exc 0.50 cum, getting out, returning filling in and ramming earth or broken rubble mixed with earth around in layers not exc 25cm, watering and removing surplus soil to a distance not exc 50 m and making good surfaces in soft/loose soil complete all as specified and as directed.
Material and labour for hardcore of broken stone or boulders of gauge not exceeding 63 mm, deposited, spread and leveled in layers not exceeding 15 cm thick, watered and rammed to a true surface complete all as specified and as directed.
Materials and Labour for plain cement concrete (1:4:8) type D-2, using 40mm graded stone aggregate as in foundations, filling and mass concrete complete all as specified and as directed.
Materials and Labour for plain cement concrete (1:3:6) type C-2, using 40mm graded stone aggregate as in foundations, filling and mass concrete incl necessary formwork complete all as specified and directed.
Materials and labour PCC 1:3:6, type C2 (using 40mm graded crushed stone aggregated) as in surfaces channels and drains incl necessary formwork complete all as specified and directed.
Extra for forming fair finished drain or channel 30 cm inner girth in cement concrete using extra cement including forms, moulds mitered/stopped ends etc. complete all as specified and directed.
M&L for brick work with sub class 'B' burnt clay bricks straight or curved on plan to any radius in half brick thick walls built in cement mortar 1:4 complete all as specified and as directed.
Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified and directed.
S&F mild steel work in framed brackets of angles or tees with web and flanges cut to shape, drilled and counter sunk for screw, including bending and welding angles as necessary gusset plates; riving etc not exceeding 10 Kg each brackets conforming to Fe-290 Gde-165 complete all as specified and directed.
Materials and Labour for Steel work in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I. S.1161-1979 grade St.-240 complete all as specified and as directed.
Materials and labour for 75 mm thick PCC (1:2:4) type B0 (using 12.5 mm graded stone aggregate) as in floor laid in panels and finished top even and smooth with using extra cement, complete all as specified and directed.
M&L for rendering 10 mm thick on fair faces of brick work or concrete surfaces in cement mortar (1:6) and finished the surfaces even and smooth without using extra cement complete all as specified and directed.
M&L for preparation of new plastered surfaces of wall and applying three coats of white wash complete all as specified and as directed.
Materials and labour for preparing of new steel surfaces of any description , over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer, complete all as specified and directed.
Preparation of new concrete brick, stone or plastered surfaces of any description over 10cm girth or width, not otherwise described of floor or wall & applying two coats of exterior acrylic emulsion of approved tint of INDIGO floor coat emulsion (platinum series) or Apex floor guard or equivalent product of approved make over a coat of white primer complete all as specified and as directed.
Preparation of new concrete brick, stone or plastered surfaces of any description not exceeding 10cm girth or width, not otherwise described of floor or wall & applying two coats of exterior acrylic emulsion of approved tint of INDIGO floor coat emulsion (platinum series) or Apex floor guard or equivalent product of approved make over a coat of white primer complete all as specified and as directed.
S&F PVC (SWR) pipes 75mm bore single socketed, in any length with rubber ring joints laid in trenches or in floors, complete all as specified and directed.
Materials and labour for forming 12mm thick expansion joints in 100 mm thick concrete slabs, filled with pre-formed bituminous filler and top 30mm primed and sealed with sealing compound, Grade ‘A’, complete all as specified and directed.
Forming Contraction (Dummy) joints 65mm deep x 10mm wide, filled with sealing compound, Grade ‘A’, complete all as specified and directed.
Supply and fixing MCB Single pole and neutral, 6 to 32 Amps, 240 volts 10 KA rupturing capacity, C series complete all as specified and directed by Engr-in-charge.
Supply and fixing of FLEXISTRIP NEON AC MONO COLOR STRIP LIGHT IP65 LED length 50mtr with stand capability upto 3.5 KV, 96 LEDs per meter, 5W/mtr, 220V-240V, 50 Hz with IP 65 complete all as specified and as directed.
S&F in repairs recess mounted deep drawn size (2 ft x 2 ft) CRCA housing having a nominal system lumen output of 3600 lumens at a minimum system efficiency of 115 lumen per watt and total power consumption not more than 36 watt including driver. It has a rated system life time of 40000 burning hours at L70 and should have a colour tempreture of 6500K with higher power LED seamless front frame with flat white hight transmission acrylic cover with built in PIR occupancy sensor offering flexibility of auto switching off when the space is not occupied complete all as specified and as directed. MAKE: Philips Cat Part No. RC383B P LED 36S- 6500 G6 PSU OD WH PIR P or its equivalent make mentioned in PS.
Supply and fixing of LED, excellent efficiency at 160lm/w and right optics baylight 250W suited for various applications, offering excellent beam and glare control, with high wattage illumination fixed on ceiling including all the equipment for installation complete all as specified and as directed. Make: Havells, Cat Pt. No. BY616P LED 300S 5700 WB PSU GR or equivalent make of mentioned in PS.
M&L for sub main wiring with two run of 2.5 Sqmm (Nominal area) single core cable PVC insulated, multistranded, unsheathed, copper conductor cables (FRLSH), 1100 Volts grade drawn through PVC casing-caping of suitable size, fixed to wall/ceiling etc including one run of 2.5 Sqmm (nominal area) single core, PVC insulated, multistranded, unsheathed, copper conductor (FRLSH) as earth wire and duly connected to common earth point complete all as specified and as directed. Note : (a) PVC Casing-caping/conduit, two run wiring cables and one run of earth wire will be measured as one length (b) All incoming and outgoing cable shall be connected by using proper lugs & sockets.
Materials and labour for clear sand cushioning with dry clean sand for protection of cable, 15cm below the cable and 8cm above the cable, complete all as specified and as directed. Note : Punned thickness shall be measured for payments.
Supply and laying well burnt bricks, sub class 'B' bricks laid breath wise across the length of cable in trenches for protection of UG cables complete all as specified and directed.
Boring of holes horizontal for laying not less than 80/50/40/32mm pipe (minimum depth 0.75 mtr from top level) under the road pavement, hard standing using trenchless technology complete all as specified and as directed. Note : cost of accessories required for making hole/bore deemed to be included in the quoted rate.
Supply, laying, jointing, commissioning and testing cross-linked polyethylene (XLPE) insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) 1100 Volt grade with stranded aluminium conductor of size 10 sq.mm 2 core, ISI marked as per IS-7098 (Part-I) 1988 including cable glands, lugs etc to suit the cable size and to be laid in trenches, under floors, through GI pipe incl taking down old unserviceable one complete all as specified and as directed. Note : (1) Pipes shall be measured and paid separately under relevant items. (2) Excavation and earth work shall be measured and paid separately. complete all as specified and directed.
Materials and labour for GI pipe 'light grade' with all fittings complete grouted in ground all as specified for 50 mm bore of pipe laid in trenches/fixed with poles/laid in road/plinth/floor for protection of cable complete all as specified and directed.
S&F in repairs integral compact wide beam high performance 200 W LED flood light luminaire made up of pressure die cast aluminium housing with toughened glass and high power LEDs and secondary lenses with IP66 protection. System efficacy ≥ 110/120LPW 10KV SPD including connecting up with 2.5 Sqmm multistranded copper conductor cables of suitable length with fixed to pole/wall, etc and testing complete all as specified and as directed.
S&F new PVC cable Junction Box IP66 "halogen free and weather proof" for out door installation size not less than 200 x 150 x 100 mm suitable for street light incoming and outgoing cables up to 10 to 25 sqmm 4 core (with terminal) & inclusive of MCB SP 10 Amp, 60A 04 strip aluminium Bus Bar, including nuts,bolts,cable glands & MS clamps fixed to pole all as directed.
Supply, laying & testing PVC insulated, PVC sheathed cable galvanized steel strip or wire unarmoured, electric control cables (Heavy duty) with stranded Aluminium conductor of size 1.5 sq mm ,2 core, 1100 Volts grade passed through PVC conduit medium grade of size Min 20mm complete all as specified and directed.
Materials and labour plain cement concrete Type B1 1:2:4 (using 20mm graded stone aggregates) as in bed block, copings, kneelers, apex stones, bed plates, kerbs , water troughs and the like including weathering, slightly rounded or chamfered angles and throating, as directed inclusive of necessary form work complete all as specified and directed.
M&L for earthing complete with GI earth plate electrode 600mm x 600mm x 6 mm thick burried directly in ground vertically to a depth not less than 2.25m below ground level with the top edge of earth plate at depth not less than 1.5m below ground level connected to galvanised earth lead wire 4.0 mm dia by means of bolts, nuts, check nuts and washers protected by 15mm bore light grade GI pipe, funnel with 20mm bore GI medium grade pipe for watering, wire mesh, including concrete pit in PCC (1:3:6) type C-1, pre-cast RCC 1:2:4 type B-1 cover slab of size 350x350x50mm reinforced with 8mm dia TMT steel bars @ 15cm centre to centre in both direction and 10mm dia MS handle of suitable size, charcoal or coke and salt in alternative layers, necessary earth work in soft/loose soil all as shown in Electrical Plate No 3 of MES Schedule Part I and testing the base in which pit cover rests made up of MS angle iron (Frame) complete as specified and as directed.
M&L for steel tubular swaged poles complete with cast iron base plate, finial taper plug, bolts, nuts & screws as specified type 410 SP-31 (9.0 metres long) including two coats of aluminium paint over a coat of primer except the planting depth which shall be painted with black bituminous paint including writing pole number using suitable paint complete all as specified and as directed. Note : Excavation and Earth work, PCC filling shall be measured and paid separately.
M/S R D CONSTRUCTION (BID ID -3463105)
Construction House (BID ID -3466364)
FREEZCON (BID ID -3466420)
AFTAB ENTERPRISES (BID ID -3465824)
Shree Trilok Electric Corporation (BID ID -3463108)
M/S A K ENTERPRISE (BID ID -3467518)
M H KHAN (BID ID -3468347)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 0.50 MB
BOQ_822815.xls
BOQ • 3.75 MB
TENDERDOCUF8957.pdf
Tender Documents • 3.02 MB
CREDIT8957.pdf
Additional Documents • 0.25 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .