Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹2.0 CrAccepted-AOC | ₹2.0 Cr | L1 | Accepted-AOC LOWEST BIDDER |
| 2 | L2₹2.0 Cr+₹74,662.50 (0.38%)Rejected-Finance NO 9 BYRAVESHWARA INDUSTRIAL ESTATE ANDRAHALLI MAIN ROAD NEAR PEENYA 2ND STAGE BENGALURU 560 091 | BENGALURU URBAN | KARNATAKA | 560091 | ₹2.0 Cr+₹74,662.50 (0.38%) | L2 | Rejected-Finance OTHER THAN L1 |
| 3 | L3₹2.0 Cr+₹6.2 L (3.12%)Rejected-Finance CHANDAN NAGAR OPP IOCL PERTROL PUMP RAMPUR ROAD BAREILLY UP 243001 | BAREILLY | BAREILLY | UTTAR PRADESH | 243001 | ₹2.0 Cr+₹6.2 L (3.12%) | L3 | Rejected-Finance OTHER THAN L1 |
| 4 | L4₹2.1 Cr+₹11.4 L (5.78%)Rejected-Finance 303 GHS 888 SECTOR 20 PANCHKULA 134116 HARYANA | PANCHKULA | PANCHKULA | HARYANA | 134116 | ₹2.1 Cr+₹11.4 L (5.78%) | L4 | Rejected-Finance OTHER THAN L1 |
| 5 | L5₹2.1 Cr+₹16.4 L (8.27%)Rejected-Finance 6313 14 PUNJABI MOHALLA AMBALA CANTT 133001 | AMBALA | HARYANA | 133001 | ₹2.1 Cr+₹16.4 L (8.27%) | L5 | Rejected-Finance OTHER THAN L1 |
Tender Value
Refer Docs
EMD Value
₹3.7 L
Closing Date
27 Sept 2021, 6:00 pmClosed
CWE MATHURA
HQ CWE MATHURA
as per tender documents
2021_MES_457744_2
CWE/MTR/E/15 of 2021-22
Open Tender
Civil Works
Item Rate
270 days
HQ CWE Mathura
Class B Cat b(ii)
8 documents required · 8 mandatory
₹2,000
GE(E) Mathura
₹3.7 L
Yes
14 Dec 2021
15 Sept 2021
29 Sept 2021
15 Sept 2021
27 Sept 2021
20 Sept 2021
Amount
Supply, laying, jointing, testing and commissioning of LT Underground XLPE insulated, screened PVC sheathed galvanized steel strip or wire armoured electric power cable (heavy duty) with stranded aluminium conductor 1100V grade of size 300 sqmm, 3.5 core laid in trenches / on pole / in ducts or through sleeves complete all as specified and directed.
Supply, laying, jointing, testing and commissioning of LT Underground XLPE insulated, screened PVC sheathed galvanized steel strip or wire armoured electric power cable (heavy duty) with stranded aluminium conductor 1100V grade of size 240 sqmm, 3.5 core laid in trenches / on pole / in ducts or through sleeves complete all as specified and directed.
Supply, laying, jointing, testing and commissioning of LT Underground XLPE insulated, screened PVC sheathed galvanized steel strip or wire armoured electric power cable (heavy duty) with stranded aluminium conductor 1100V grade of size 185 sqmm, 3.5 core laid in trenches / on pole / in ducts or through sleeves complete all as specified and directed.
Supply, laying, jointing, testing and commissioning of LT Underground XLPE insulated, screened PVC sheathed galvanized steel strip or wire armoured electric power cable (heavy duty) with stranded aluminium conductor 1100V grade of size 150 sqmm, 3.5 core laid in trenches / on pole / in ducts or through sleeves complete all as specified and directed.
Supply, laying, jointing, testing and commissioning of LT Underground XLPE insulated, screened PVC sheathed galvanized steel strip or wire armoured electric power cable (heavy duty) with stranded aluminium conductor 1100V grade of size 120 sqmm, 3.5 core laid in trenches / on pole / in ducts or through sleeves complete all as specified and directed.
Supply, laying, jointing, testing and commissioning of LT Underground XLPE insulated, screened PVC sheathed galvanized steel strip or wire armoured electric power cable (heavy duty) with stranded aluminium conductor 1100V grade of size 95 sqmm, 3.5 core laid in trenches / on pole / in ducts or through sleeves complete all as specified and directed.
Supply, laying, jointing, testing and commissioning of LT Underground XLPE insulated, screened PVC sheathed galvanized steel strip or wire armoured electric power cable (heavy duty) with stranded aluminium conductor 1100V grade of size 70 sqmm, 3.5 core laid in trenches / on pole / in ducts or through sleeves complete all as specified and directed.
Supply, laying, jointing, testing and commissioning of LT Underground XLPE insulated, screened PVC sheathed galvanized steel strip or wire armoured electric power cable (heavy duty) with stranded aluminium conductor 1100V grade of size 50 sqmm, 3.5 core laid in trenches / on pole / in ducts or through sleeves complete all as specified and directed.
Supply, laying, jointing, testing and commissioning of LT Underground XLPE insulated, screened PVC sheathed galvanized steel strip or wire armoured electric power cable (heavy duty) with stranded aluminium conductor 1100V grade of size 35 sqmm, 3.5 core laid in trenches / on pole / in ducts or through sleeves complete all as specified and directed.
Supply, laying, jointing, testing and commissioning of LT Underground XLPE insulated, screened PVC sheathed galvanized steel strip or wire armoured electric power cable (heavy duty) with stranded aluminium conductor 1100V grade of size 25 sqmm, 3.5 core laid in trenches / on pole / in ducts or through sleeves complete all as specified and directed.
Supply, laying, jointing, testing and commissioning of LT Underground XLPE insulated, screened PVC sheathed galvanized steel strip or wire armoured electric power cable (heavy duty) with stranded aluminium conductor 1100V grade of size 16 sqmm, 4 core laid in trenches / on pole / in ducts or through sleeves complete all as specified and directed.
Supply, laying, jointing, testing and commissioning of LT Underground XLPE insulated, screened PVC sheathed galvanized steel strip or wire armoured electric power cable (heavy duty) with stranded aluminium conductor 1100V grade of size 10 sqmm, 4 core laid in trenches / on pole / in ducts or through sleeves complete all as specified and directed.
Excavation in trenches for laying under ground cable, erection of poles and stays in soft / loose soil not exceeding 1.5 meter wide and not exceeding 1.5 meter deep and getting out complete all as specified and directed.
Excavation in trenches for laying under ground cable, erection of poles and stays in PCC / floor / road not exceeding 1.5 meter wide and not exceeding 1.5 meter deep and getting out complete all as specified and directed.
Excavation in trenches for laying under ground cable, erection of poles and stays in soft / loose soil not exceeding 1.5 meter wide and exceeding 1.5m but n.exc 3.00m deep and getting out complete all as specified and directed. Note : For item Sl No 13, 14 & 15, If any existing electric cables/ Telephone line/ OFC cable,water pipe line etc is damaged by the contractor during the execution of work, it will be repaired/ replaced as per existing by the contractor at his own expense to the satisfaction of Engr-in-Charge.
Returning, filling in including spreading, levelling, watering and well ramming in layers not exceeding 25 cm thick complete all as specified and directed.
Removing surplus excavated material to a distance not exceeding 50 meter and depositing where directed at a level not exc 1.5m above the starting point complete all as specified and directed.
M&L for dry clean sand in sand cushioning to under ground cable in trenches/existing cable trenches / ducts in layers complete all as specified and directed. Note : Punned thickness shall be measured.
Supplying and laying reinforced precast cement concrete cable cover class HV type 2 with peak size 450mm x 180mm x 40mm for cable protection complete all as specified and directed.
Supplying and laying un-reinforced precast concrete cable cover class LV type 1, flat, size 250mm x 150mm x 40mm for cable protection complete all as specified and directed.
M&L for Cable route indicator showing "MES HT 11 KV UG Cable" and route of cable with arrow made of CI in suitable eliptical shape and fixed on angle iron 40 x 40 x 6mm, 800mm long painted in Brown Colour with two coats of synthetic enamel paint over a coat of red oxide primer duly embaded in and including PCC 1:4:8 type D-2 (using 20mm graded stone aggregate) block 0.40 x 0.40 x 0.40 mtr in ground and 0.15m above ground level complete all as specified and directed.
M&L for Cable route indicator showing "MES LT UG Cable" and route of cable with arrow made of CI in suitable eliptical / round shape and fixed on angle iron 40 x 40 x 6mm, 800mm long painted in Blue Colour with two coats of synthetic enamel paint over a coat of red oxide primer duly embaded in and including PCC 1:4:8 type D-2 (using 20mm graded stone aggregate) block (0.40 x 0.40 x 0.40) mtr in ground and 0.15mtr above ground level complete all as directed and specified.
S&F galvanised steel tube, light grade laid along the pole / in trenches / under road or floor of size 100 mm bore complete all as specified and directed.
S&F galvanised steel tube, light grade laid along the pole / in trenches / under road or floor of size 80 mm bore complete all as specified and directed.
S&F galvanised steel tube, light grade laid along the pole / in trenches / under road or floor of size 50 mm bore complete all as specified and directed.
S&F galvanised steel tube, light grade laid along the pole / in trenches / under road or floor of size 40 mm bore complete all as specified and directed.
Supply, install, testing and commissioning of CPRI approved factory made 3 phase, 4 wire, 415V, LT panel cubicle outdoor type with IP 54 protection, made of 3.15mm thick mild steel CRCA sheet duly powder coated for outdoor cover and 2mm thick for inside panel board with double doors dust, vermin and water proof 400 A rating 8 Way MCCB Module (TP) mounted on and including PCC 1:3:6 type C-1 (using 20mm graded stone aggregate) as in foundation of suitable size, I/C and O/G cable connections, internal wiring with suitable size of copper cable complete all as specified and comprising the following :- (For Bahadurgarh Area)
(a) MCCB 400 Amp,4P, 35KA adjustable thermal and adjustable magnetic (I/C) - 01 No (b) MCCB, 160A, 25KA, 3 Pole fixed thermal and fixed magnetic (O/G) - 02 Nos (1 For FPB - 1 & 1 For Bas Bar) (c) MCCB, 100A, 25 KA, 3 Pole fixed thermal and fixed magnetic (O/G) - 02 Nos (1 For FPB - 2 & 1 For Bas Bar) (d) MCCB, 63A, 25 KA, 3 Pole fixed thermal and fixed magnetic (O/G) - 02 Nos (1 For Bus Bar & 1 For St Lt & 1 Nos Bare Module for future use purpose) (e) Pre-wired Digital meter with voltmeter, ammeter, slector switch, CTs, Control Fuse and Indicating Lights - 01 Set (f) Cable Alley double door type I/C with aluminium bus bar (RYB&N) 400A, O/G 3 Pole 8 Way - 01 Set (LHS & RHS)
Supply, install, testing and commissioning of CPRI approved factory made 3 phase, 4 wire, 415V, LT panel cubicle outdoor type with IP 54 protection, made of 3.15mm thick mild steel CRCA sheet duly powder coated for outdoor cover and 2mm thick for inside panel board with double doors dust, vermin and water proof 400 A rating 8 Way MCCB Module (TP) including PCC 1:3:6 type C-1 (using 20mm graded stone aggregate) as in foundation of suitable size, I/C and O/G cable connections, internal wiring with suitable size of copper cable complete all as specified and comprising the following :- (For Surya I & II Area)
(a) MCCB 400 Amp, 4P, 35KA adjustable thermal and adjustable magnetic (I/C) - 01 No (b) MCCB, 160A, 25KA, 3 Pole fixed thermal and fixed magnetic (O/G) - 02 Nos (1 For FPB - 1 & 1 For Bas Bar) (c) MCCB, 100A, 25 KA, 3 Pole fixed thermal and fixed magnetic (O/G) - 01 Nos (For FPB -2) (d) MCCB, 63A, 25 KA, 3 Pole fixed thermal and fixed magnetic (O/G) - 04 Nos (3 For Bus Bar & 1 For St Lt) (e) Pre-wired Digital meter with voltmeter, ammeter, slector switch, CTs, Control Fuse and Indicating Lights - 01 Set (f) Cable Alley double door type I/C with aluminium bus bar (RYB&N) 400A, O/G 3 Pole 8 Way - 01 Set (LHS & RHS)
Supply, install, testing and commissioning of CPRI approved factory made 3 phase, 4 wire, 415V, LT panel cubicle outdoor type with IP 54 protection, made of 3.15mm thick mild steel CRCA sheet duly powder coated for outdoor cover and 2mm thick for inside panel board with double doors dust, vermin and water proof 400 A rating 12 Way MCCB Module (TP) including PCC 1:3:6 type C-1 (using 20mm graded stone aggregate) as in foundation of suitable size, I/C and O/G cable connections, internal wiring with suitable size of copper cable complete all as specified and comprising the following :- (For Old RATC Area)
(a) MCCB 400 Amp, 4P, 35KA adjustable thermal and adjustable magnetic (I/C) - 01 No (b) MCCB, 160A, 25KA, 3 Pole fixed thermal and fixed magnetic (O/G) - 02 Nos (1 For FPB - 1 & 1 For Bas Bar) (c) MCCB, 100A, 25 KA, 3 Pole fixed thermal and fixed magnetic (O/G) - 04 Nos (1 for FPB -2 & 1 for FPB- 3 & 02 Nos for Bus Bar) (d) MCCB, 63A, 25 KA, 3 Pole fixed thermal and fixed magnetic (O/G) - 03 Nos (2 Nos For Bus Bar & 1 For St Lt & 02 Nos Bare Module in LHS & RHS at Cable Alley for future use) (e) Pre-wired Digital meter with voltmeter, ammeter, slector switch, CTs, Control Fuse and Indicating Lights - 01 Set (f) Cable Alley double door type I/C with aluminium bus bar (RYB&N) 400A, O/G 3 Pole 12 Way - 01 Set (LHS & RHS)
Supply, install, testing and commissioning of CPRI approved factory made 3 phase, 4 wire, 415 volts, out door cubicle type with IP 54 protection LT feeder pillar box double doors dust, vermin and water proof 250 Amp Rating with inside panel board made out of 3.15 mm thick CRCA powder coated sheet for outer cover and 2mm thick for inside panel board with front and rear operated doors fitted with necessary hinges, making the locking arrangement including cable alley with aluminium bus bars 250 Amps rating both side, internal wiring with copper wire and provn of incomming / outgoing cable way and duly mounted on 45x45x3mm thick angle iron stand and 4 legs 750mm long each 450mm grouted in PCC 1:3:6 type C-1 (using 20mm graded stone aggregate) and complete fixing of 2 Nos LT danger notice plates of standard size complete suitable for acommodating and including following accessories :-
(a) MCCB, 160A, 25KA, 4Pole fixed thermal and fixed magnetic (Incommer) - 01 Nos (b) MCCB, 160A, 25KA, 3 Pole fixed thermal and fixed magnetic (O/G) - 01 Nos (Outgoing) (c) Cable Alley with Aluminium Bus bar (RYB &N) 250 Amps Rating both side of feeder Piller Box - 01 Set (LHS & RHS) (d) Three Phase LED Indicator switch RY & B
S&F of Bus Bar Chamber outdoor type made out of 1.6 mm thick CRCA sheet 8 way TPN 250 Amps Bus Bar rating including fixing on Wall / Pole with suitable size of clamp, Nut & Bolt or as per site requirement for fixing of outdoor site with provision of angle iron legs 45 x 45 x 3 mm, 750mm long for grouted with PCC and incommer and outgoing cable connections with suitable size of lugs complete all as specified and directed.
S&F 4 Pole 415 Volts MCCB enclousers Box including MCCB 4 Pole 63 Amps, rupturing capacity 25 KA with fixed thermal and fixed magnetic setting complete with all incomming and outgoing connection as per site requirment complete all as specified and directed.
Dismantling / taking down stay assembly complete any type & description complete all as specified and directed.
Dismantling / taking down of ACSR conductor from electric poles of any description complete all as specified and directed.
Dismantling / taking down insulators any type / size from electric poles of any description complete all as specified and directed.
Dismantling / taking down cross-arms and bracing any type / size from electric poles any description complete all as specified and directed.
Dismantling / taking down GI earth wire any type / size from electric poles any description complete all as specified and directed.
Supply laying & testing U/G cable XLPE insulated screened PVC bedded galvanised steel strip armoured elect power cable heavy duty with stranded compact circular aluminium conductor 11000 volts grade earthed system of cross section area 120 Sqmm x 3 core complete with confirming to IS 7098 (Part-II) 2011 with updated amendments incl laid in trenches / duct / boring hole / fixing on walls /poles or passing through pipe including connecting with installations / equipments / GOD and testing complete all as specified and directed. Note : Cable Joint kit shall be measured and paid separately under respective item.
Supply and erecting Pole in true vertical position with steel tubular swaged pole 11 mtr long type 410 SP-55 complete with cast iron base plate and closed at top, painted internally throughout and externally up to the embedded depth with two coats of black bitumnous paint and remaining external portion with two coats of aluminium paint over a coat of red oxide primer including providing black and white strips with synthetic enamel paint 30cm each alternate layers upto 1.5m above the coping of the pole starting with black strip and numbering the pole (with black and white paint), complete all as specified and directed. Note : Earth work , PCC foundation and cross arms shall be measured and paid separately under respective item.
M&L for MS work confirming to Fe-410-O or Fe-310-O as in cross arms, support, bracings, stiffeners, clamps channels fabricated from structural steel including nuts, bolts and washers welding, bending cold or hot drilling holes for bolts in any shape or size all as directed including two coats of aluminium paint over a coating of red oxide primer complete all as specified and directed.
S&F Danger notice plate for 11KV HT poles size 1.6mm thick mild steel sheet vitreous enemelled white letter figures and conventional skull and bones marked in red colour with MS clamp of flate iron 25 x 3mm size, bolts, nuts, size of plate 25 x 20Cm complete all as specified and directed.
M&L for anti climbing devices, spike type fabricated out of MS bars (Round, square and flat) including nuts, bolt, washers and welding in two halves made to shape to suit the cross section of the pole including painting etc complete all as specified and as directed.
M&L for Plain Cement Concrete 1:2:4 type B-1 using 20mm graded stone aggregate for coping around poles, including provision of necessary form work, finishing even and smooth without using extra cement complete all as specified and directed.
M&L Plain Cement Concrete 1:3:6 type C-2 using 40mm graded stone aggregate as in foundation of poles, stays, filling of road cuttings etc. complete all as specified and directed.
S&F Gang operated Air Break Switch outdoor type 11 KV, 200 Amp capacity tripple pole machenically operated suitable for operation from ground level and for vertical mounting complete with HT insulators 9 Nos with earth switch, channel, knife blades, GI pipe medium grade not below 25 mm dia for operating mechanism worked from ground level, locking arrangement with handle all as specified. Make - Jaipuria Brothers Electricals Pvt Ltd (JBEPL)or equivalent in Pactil, Rashtriya electrical & Engr. Corp
M&L for HT 11 KV lightning arrestors expulsion type complete with all fittings, having discharge capacity of 65 KA, suitable for 11 KV HT line including making connection with GI earth strip / wire & HT connection with used of ACSR conductor complete with testing complete all as specified and directed. Make - Rashtriya electrical & Engr. Corp or equivalent in Jaipuria Brothers, Pactil
S&F cable jointing kit 11 KV (earthed) grade cable for outdoor end termination cold shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor HT cable of size 120 Sqmm complete all as specified and directed. Make : Densons or equivalent in 3M, Raychem
S&F cable jointing kit 11 KV (earthed) grade cable for Indoor end termination cold shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor HT cable of size 120 Sqmm complete all as specified and directed. Make : Densons or equivalent in 3M, Raychem
Supply, installation, commissioning and testing of HT 11 KV 3-phase totally enclosed metal clad SF6 Ring Main Unit switch gear 4 way type (02 incoming & two outgoing) suitable for outdoor installation having rupturing capacity upto 350MVA, overload and earth fault protection, ammeter, voltmeter and of rating 630 Amp complete accessories / fitments for 4 way RMU complete all as specified and as per following standard norms :- Make : ABB / Schneider / SIEMENS / L&T / Legrand Note :- Unit rate shall included the cost of danger notice board, 11KV grade 25 cm CRCA ISI Marked, 11 KV grade, Two sets of operating and maintenence manual, spares list, periodical mainenance chart / manual, lay out of panel / wiring shall be included in the rate quoted.
(a) Parameters of Ring Main Unit switchgear :- (i) Rated voltage (nominal / max) : 11KV/12 KV (ii) Type / service : SF-6 Ring main unit switch gear 4 way (02 Nos I/C LBS & 02 Nos O/G CB / Outdoor (iii) Frequency : 50 Hz (iv) No of phases : 3 (v ) System neutral : Effectively earthed (vi) Impulse Voltage withstand : 75 KVp (vii) Rated continuous current : 630A (viii) 1 Minute power frequency withstand voltage : 28 KV r.m.s. (ix) Short time current for 3 secs : 21 KA (x) Rated current Busbar : 630 Amp (xi) Operating mechanism : Motor operated spring charged closing mechanism.
(b) Protection system (i) Triple pole IDMT over load current / earth fault relay with instant elements (3 O/C + 1 E/ F) on all three phases . (ii) Master trip relay protection.
(d) Provn for manual charging of the operating system of 'ON' and 'OFF' (e) Provn of motor operated spring stored energy trip and closing coil system (f) Auxiliary switches as suitable for system at (d) and (e) above (g) Set of CTs in resin cast wound double core for system voltage, 11 KV with double ratio suitable to above system / capacity CTs - 03 Nos (h) Set of PT's resin cast, 3 phase, 11 KV. (j) Necessary HT & LT fuses for metering and protection (k) Power and control wiring with copper cables (l) Any other accessries, control which are required as per standard norms and engineering practice, IE rules to ensure system safe for operation and maintenance of Ring main unit switchgear. (m) Auxillary power supply unit for operation of relays, meters complete all as per standard norms.
M&L for boring of holes under road, Pavement, Hard standing or as directed by trenchless technology using ultra sounding technique and necessary machine for crossing of XLPE cable as per standard technical specification with and including HDPE pipe of dia not less than 150mm suitable for 0.4Mpa working pressure and vertical depth n.exc. 2 mtr and horizontal dia n.exc. 200mm and including getting out, removing excavated surplus soil to a distance not exceeding 50 mtr and depositing where as directed at a level n.exc 1.5m above starting point complete all as specified and directed.
M&L for earthing complete with galvanized steel earth plate electrode size 600mm x 600mm x 6mm thick buried directly in ground vertically in a pit of depth not less than 2.25 mtr below ground levels with top edge of the earth plate not less than 1.5 mtr below normal ground level surrounded from all sides by mixture of charcoal and common salt and electrode connected to and including galvanized iron Wire 4mm dia as earthing lead by means of bolts, nuts, check nuts and washers of galvanized including GI protection pipe light grade 15mm dia connected to main earth lead on pole or control board and GI pipe medium grade 20 mm dia for watering funnel with wire mesh. CI cover with frame, PCC chamber pit with PCC (1:3:6) type C-2 including necessary excavation and earth work all as shown in electrical plate No 3 connected to earthing test point and testing complete all as specified & directed. Note : GI wire & protection pipe beyond 7.5 Mtr length from earth electrode shall be measured and paid separately.
M&L for earthing of machinery / equipment / Panel etc. complete with galvanized steel earth plate electrode size 600 mm x 600 mm x 6 mm thick buried directly in ground vertically in a pit of depth not less than 2.25 mtr below ground levels with top edge of the earth plate not less than 1.5 mtr below normal ground level surrounded from all sides by mixture of charcoal and common salt and electrode connected to and including galvanized iron strip 32 x 6mm as earthing lead by means of bolts, nuts, check nuts and washers of galvanized including GI protection pipe light grade 40mm dia connected to main earth lead on pole or control board and GI pipe medium grade 20 mm dia for watering funnel with wire mesh. CI cover with frame, PCC chamber pit with PCC (1:3:6) type C-2 including necessary excavation and earth work all as shown in electrical plate No 3 connected to earthing test point and testing on completion complete all as specified & directed. Note : GI strip & protection pipe beyond 7.5 Mtr length from earth electrode shall be measured and paid separately
M&L for GI Pipe light grade 15mm bore for earth wire protection in ground / floor / hard standing / along pole complete all as specified & directed.
M&L for GI wire 4mm dia as earth continuity conductor burried in ground or drawn in pipe or fixed to wall on saddle complete all as specified and directed.
S&F earthing strip 32x6mm galvanized iron fixed to wall / pole / buried in ground / drawn in pipe complete all as specified and directed.
Supply and fixing moulding compound street light junction box of size 250mm x 250mm x 160mm complete with shock and rust proof, termite resistant, tamper proof, front openable type and including suitable provision for three phase, four wire cable (size upto 25 Sqmm 4 Core) incomming & outgoing loop-in loop connection and including one no. MCB SP 6 Amp including non metallic clamps and GI nut bolts and washers of suitable size and fixed on pole / wall complete all as specified and directed. Make - Sintex or equivalent in Hensel / ABB.
Supply & fixing PVC insulated FRLS unsheathed flexible copper conductor cable of size 1.5 Sqmm, multistranded, three core, 1100 volts grade for connecting from loop in - loop out box to street light fitting including PVC pipe with binding strip complete all as specified and directed. Make : Havells / Plaza / Finolex / Polycab
M&L for repairing road cutting with premix ready mix road patching compound including preparing the surface, pouring of compound, spreading and compacting to match with existing road complete all as per manufacturers instruction and as directed by Engr in Charge. Make : Instapatch/ Patch Mate/ Hincol.
Vijay Electricals
BHARAT ELECTRICAL TRADERS
R D Bansal
Sham Sunder Bansal
Commercial Traders
KR POWER INFRA INDIA PVT LTD.
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .