Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹30.6 LAccepted-AOC | L1 | Accepted-AOC Reasonable | |
| 2 | L2₹31.9 L+₹1.3 L (4.23%)Rejected-Finance | L2 | Rejected-Finance Being other than L1 | |
| 3 | L3₹32.0 L+₹1.4 L (4.51%)Rejected-Finance H NO 400 STREET NO 1 SAIN GHAR PATHANKOT GURDASPUR PUNJAB 145001 | PATHANKOT | PUNJAB | 145001 | L3 | Rejected-Finance Being other than L1 | |
| 4 | L4₹32.0 L+₹1.4 L (4.62%)Rejected-Finance | L4 | Rejected-Finance Being other than L1 | |
| 5 | L5₹33.2 L+₹2.7 L (8.69%)Rejected-Finance | L5 | Rejected-Finance Being other than L1 |
Tender Value
₹48 L
EMD Value
₹96,000
Closing Date
23 Jun 2020, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (AF) PATHANKOT
GE (AF) PATHANKOT-145001
REPAIR TO CERTAIN RIGID PAVEMENTS IN TECHNICAL AREA AT AIR FORCE STATION PATHANKOT
2020_MES_349274_1
8419/GE/PAF-11
Open Tender
Civil Works
Item Rate
180 days
GE (AF) PATHANKOT
As per NIT
8 documents required · 8 mandatory
₹500
GE (AF) PATHANKOT
₹96,000
Yes
22 Jul 2020
2 Jun 2020
25 Jun 2020
2 Jun 2020
23 Jun 2020
16 Jun 2020
60 days
Amount
Racking out existing filling in dummy/construction joints upto 25mm width and depth as required to provide backup rod and minimum 15mm thick sealant compound and making it perfectly U shaped with vertical sides by means of mechanical cutter and ensure that joints should be cleaned to remove sealing compound from sides of joint, after cleaning and fanning with air compressor to make the joints free from all loose material (i.e. dirt/dust etc ) and provide polyethylene foam rod backup material of suitable size (Backup rod to be fixed with wooden roller) and applying primer of approved make to side and bottom of joints and filling with polyurethane sealant of approved make(minimum 15mm thick over backup rod), all as manufacturer instruction and old material should be removed from Technical area as directed by Engineer-in-Charge. Make : Bostic, Seal N Flex 2K or any equivalent product E-in-C's approved list. Note: (1) Masking tape on edge of joint to be provided on top surface to give neat finish to sealant and removing the masking tape after sealant is applied. (2) An exclusive team of 06 labourers shall be deployed for performing the task such as removing of existing fiiling, cleaning of open opened joint, finishing of edges with grinder/cutter, applying of primer by one forward stroke and second backward stroke of brush, then applying joint sealant after appropriate time gap and as per directed by the Manufacturer's instruction, manual and directed by the Engrs-In-Charge. (3) Being important nature of work related to availability of runway, contractor is advice to ensure availability of joint material at all times. At no point excuse of non-delivery of material by the authorised manufacture will be accepted as a valid reason for allowing delay in execution.
Racking out existing filling in dummy/construction joints above 25mm width and depth as required to provide backup rod and minimum 15mm thick sealant compound and making it perfectly U shaped with vertical sides by means of mechanical cutter and ensure that joints should be cleaned to remove sealing compound from sides of joint, after cleaning and fanning with air compressor to make the joints free from all loose material (i.e. dirt/dust etc ) and provide polyethylene foam rod backup material of suitable size (Backup rod to be fixed with wooden roller) and applying primer of approved make to side and bottom of joints and filling with polyurethane sealant of approved make(minimum 15mm thick over backup rod), all as manufacturer instruction and old material should be removed from Technical area as directed by Engineer-in-Charge. Make : Bostic, Seal N Flex 2K or any equivalent product E-in-C's approved list. Note:(1) Masking tape on edge of joint to be provided on top surface to give neat finish to sealant and removing the masking tape after sealant is applied. (2) An exclusive team of 06 labourers shall be deployed for performing the task such as removing of existing fiiling, cleaning of open opened joint, finishing of edges with grinder/cutter, applying of primer by one forward stroke and second backward stroke of brush, then applying joint sealant after appropriate time gap and as per directed by the Manufacturer's instruction, manual and directed by the Engrs-In-Charge. (3) Being important nature of work related to availability of runway, contractor is advice to ensure availability of joint material at all times. At no point excuse of non-delivery of material by the authorised manufacture will be accepted as a valid reason for allowing delay in execution.
Racking out existing filling in dummy/construction joints and removing old material outside Technical area and filling joint with filling compound Grade B of approved make (Approximate size of joint 10 to 30 mm wide and 30mm depth) complete all as per manufacturers instruction and as directed by Engineer-in-Charge.(Make-SN/SIKA/FOSROC or any equivalent product E-in-C's approved list).
M/S G P MARWAHA
pardeep singh marwaha
M/S SINGHAL ENGINEERS
M/S HARBANS SINGH BEDI
RAJESH SHARMA AND COMPANY
BUILDEX CONSTRUCTION CO
SB TRADING CO
INDERJIT SINGH
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .