REPAIR/MAINT OF HT DISTRIBUTION TRANSFORMER HT PANELS AND GOD HT DISTRIBUTION NETWORK AND CONNECTED ITEMS AT GE (AF) AWANTIPUR
2023_MES_606417_1
CWE(AF)SGR/AWA-15/2023-24
Open Tender
Civil Works
Item Rate
180 days
AF STN AWANTIPUR
AS PER NIT
8 documents required · 8 mandatory
₹500
GE AF AWANTIPUR
₹50,000
Yes
22 Sept 2023
28 Jun 2023
25 Aug 2023
28 Jun 2023
23 Aug 2023
9 Aug 2023
Amount
Excavation in trenches not exceeding 1.5 mtr wide and not exceeding 1.5 mtr in depth in soft/loose soil for laying of cables or other items and getting out complete all as specifed and directed.
Returning filling in including spreading levelling watering and well ramming in layers not exceeding 25 cm complete all as specified and directed.
Removing excavated material not exceeding 50 mtr and depositing where directed in a level not exceeding 1.5 mtr above the starting point of any type of soil complete all as specified and directed.
Taking out burnt/unserviceable HT cable of any size from existing trench and keeping aside.
Supply and laying and testing XLPE insulated screened PVC bedded, galvanized steel strip or wire armored heavy duty 11000 Volts grade with stranded aluminium conductor 120 Sqmm 3 core all as specified and directed.
Supply and laying and testing XLPE insulated screened PVC bedded, galvanized steel strip or wire armored heavy duty 11000 Volts grade with stranded aluminium conductor 240 Sqmm 3 core all as specified and directed.
Material and labour for sand cushning to under ground cable provided with a layer of sand 8 cm depth before laying of cable and 15 cm depth after laying and stretching the cable all as specified and directed.
Supplying and laying un-reinforced precast concrete cable cover, class HVP,type 1 with peak, size 300mm x 180mm x 40mm, laid dry flat in trenches for protection of cable over HT cable, complete all as specified and as directed.
Taking out old rusted GI pipe and supply and fixing tubing 'light grade' galvanised iron with all fittings and fixed to poles, walls etc. with flat iron clamps/bolts/nuts/washers or laid in floors/under roads complete all as specified and directed of the following bores :- (a) 100 mm bore
Material and labour for cable jointing kit for 11 KV (earthed) grade cable for outdoor type termination heat shrink type joint complete with jointing material and allied accessories suitable for 3 core XLPE/ PVC insulated armoured aluminium conductor cable of size 240 sqmm complete, all as specified and directed.
Material and labour for cable jointing kit for 11 KV (earthed) grade cable for staight through heat shrink type joint complete with jointing material and allied accessories suitable for 3 core XLPE/ PVC insulated armoured aluminium conductor cable of size 120sqmm complete, all as specified and directed.
Dismantling air break gang operated switch vertical/horizontal mounted including insulators and operating mechanism for replacement and removal from site all as specified and directed.
Supply and fixing air break, gang operated switches ,11KV, triple pole,vertically mounted type, mechanically operated, mounted on mild steel channel with operating mechanism, worked from ground level, for current rating upto 200 Amps with drop out fuse element of required capacity,GOD/switch having 100 MVA rating at 11 KV and 12 insulators suitable for 11 KV,50 C/s including mounting on HT poles, making neccesary electric connections and testing complete all as specified and directed.
Material and labour for replacement of HT bush rod complete with HT bushing and bush rod of size (15-20)mm Ø comprising of the required nut along with check nut complete as per sample.
Material and labour for replacement of HT bush rod complete with HT bushing and bush rod of size 25mm Ø comprising of the required nut along with check nut complete as per sample.
Material and labour for replacement of LT bushing (Brass stud and bolts with porcelian insulator) suitable size to fixed the transformer capacity range upto 1000 KVA including replacement of gasket , cable glands, etc to make the transformer leak proof bush rod of size (20-25)mm Ø comprising of the required nut along with check nut complete as per sample complete all as specified and directed.
Supply and fixing breather assembly complete with silica gel crystal impregnated with cobalt suitable for any model of transformer rating 50 to 160 KVA to air column of conservator tank complete, all as specified and directed.
Description al as per Srl items No 17 here-in-before but for transformer rating 200 KVA upto 350 KVA complete, all as specified and directed.
Description al as per Srl items No 17 here-in-before but for transformer rating 400 KVA upto 500 KVA complete, all as specified and directed.
Supply and filling transformer oil of any approved make to top up with BDV not less than 50KV in electrode gap of 2.5mm in first tripping, having low viscosity for filling or replacing the old oil complete, all as specified and directed. Make: Savita/Power oil as per IS 335 of 1983 all as specified.
Taking proper shut down and disconnecting up the LT and HT electric mains from transformer of capacity 50 KVA to 160 KVA removing the lid/cover for inspection at site and to facilitate minor repairs after draining out the transformer oil reassembling the transformer refilling the transformer oil (new or old) installing, commissioning and testing at site complete all as specified and directed. Note: All the parts required to be replaced shall be measured and paid separately.
Description all as per Srl item No.21 here in before but for transformer of capacity exceeding 200 KVA to 500 KVA.
Taking proper shut down in writing and disconnecting the LT and HT electric mains from transformer of capacity 50 KVA to 160 KVA removing the transformer from pole structure/platform shifting to authorised workshop after draining out the transformer oil at site, dismantling and disconnecting damaged HT/LT coils to facilitate necessary repairs, rewinding/reconditioning, changing of gasket & re-assembling the transformer bringing back to the site, refilling new or dehydrated old oil connecting with existing electrical system of HT and LT electric mains including testing complete, all as specified and directed. Note :(i) Winding wire and other items mentioned in Sch ‘A’ will be measured and paid separately in respective schedule. (ii) Placing /removing standby transformer in the place of defective transformer under repair will be the responsibility of the contractor, including transportation and man power Standby transformer will be provided by the deptt
Description all as per Srl item No.23 here-in-before but transformer of capacity exceeding 200 KVA to 500 KVA.
Material and labour for rewinding of HT coil conforming to the original winding of the transformer of any make/capacity with super enamelled cooper wire/strip of appropriate gauge and turns including allied materials such as insulation, varnish etc complete, all as specified and directed.
Material and labour for rewinding of LT coil conforming to the original winding of the transformer of any make/capacity with super enamelled cooper wire/strip of appropriate gauge and turns including allied materials such as insulation, varnish etc complete, all as specified and directed.
Material and labour for Top gasket sheet made out of cork sheet with suitable GI bolts, nuts, washers for transformer top cover complete for transformer of any capacity all as specified and directed.
Dehydration and Filteration of existing serviceable oil in the transformer till it acheive dielectric strenght not less then 35KV in first tripping after dehydration with minimum electrode gap 5mm using dehydration plant complete, all as specified and directed.
Cleaning the existing exposed surfaces of steel tubular pole 11 Metre long including cross arms, brackets, clamps etc including scraping the worn out paint and making the surface smooth and painting with two coats of synthetic enamel paint (aluminium shade), marking five black & white bands at lower portion of pole, each 300 mm wide alternatively including marking pole No. with yellow paint on black base at suitable height complete all as specified and directed.
Material and labour for servicing of 33 KV VCB / 11KV VCB / bus coupler by dismantling cleaning greasing the complete VCB with attached relays bus bar etc insulation testing, setting the contact gap by measuring as required reassembling the VCB and reinstalling back to its original position checking and repairing the current circuit panel wiring, replacement of new spares as required complete including operational testing and comrnissioning all as specified and directed. (Note : New spares will be measured and paid separately under relavent item of' this schedule)
Supply, connecting and testing tripping coil DC 30/24 Volt suitable for 11KV VCB panel complete all as specified and directed.
Supply, connecting and testing closing coil DC 30/24 Volt suitable for 11KV VCB panel complete all as specified and directed.
Supply, connecting Ammeter digital type with CT ratio 100/5 and current rating0-50 Amp suitable for 11 KV VCB panel complete all as specified and directed.
Supply, connecting Voltmeter digital type 0-15 KV PT ratio, 11KV/110 Volt suitable for 11 KV VCB panel complete all as specified and directed.
Supply and fixing LED type indicating lamp fitting suitable for 24 /30 Volt DC complete all as specified and directed.
Suply only gear system assy complete with handle for charging discharging of VCBs complete all as specified and directed.
Supply only spring charging motor for VCBs complete all as specified and directed by Engr in charge.
Supply only breaker control switch for 11 KV breakers. Make- Kaycee
Supply only Auxiliary spring set as per sample.
Supply only Vacuum interrupter type WL3379M3.Make-CG DISPNOS-65459 or as per existing
Supply and fixing microprocessor based over current and earth fault relay with highest element event recording & current scanning/display feature suitable for 30 Vto 110 V AC/DC. Make- siemens or as per existing
Supply and fixing 11 KV current transformer suitable for VCB of ratio 50-25/5A match with as per existing CT complete all as specified and directed.
Material and labour for cutting of bitumen road/PCC road/hard standing for laying of GI pipe and passing of cable including making good to disturbed surface with PCC 1:4:8 and matching with existing surface complete all as specified.
Material and labour for cement concreate on foundation filling and mass concreate type C2 with PCC 1:3:6 and 40mm aggregate complete all as specified and directed.
Material and labour earthing complete with galvanised steel earth plate electrode 60cmx 60cm x6mm thick burried directly in ground ( earth pit not less than 2.25 mtr below normal ground level ) connected to and including galvanised iron strip 25x4mm by means of bolts nuts check nuts and washers of galvanised iron or steel including PCC pit in PCC 1:2:4 type B-1 RCC cover made out of cement concrete 1:2:4 type B-1 (using 20 mm grade crushed stone aggregate) reinforced with TMT steel bars 8 mm dia @150 mm c/c both ways with suitable handle and angle iron 40x40x5mm frame, GI medium grade watering pipe 20mm bore and funnel with wire mesh light grade protection pipe 40mm bore upto main board complete as shown on electrical plate No 3 of MES Sch 2009 (Part-I) and testing on completion all as directed. Note: On testing after completion of earthing, if desired earth resistance is not obtained, the earthing will be re-done by the contractor at his own risk & cost to the entire satisfaction of Engineer-in-charge.
Material and labour earthing complete with copper earth plate electrode 60cmx 60cm x6mm thick burried directly in ground ( earth pit not less than 2.25 mtr below normal ground level ) connected to and including copper strip 25x3mm by means of bolts nuts check nuts and washers of galvanised iron or steel including PCC pit in PCC 1:2:4 type B-1 RCC cover made out of cement concrete 1:2:4 type B-1 (using 20 mm grade crushed stone aggregate) reinforced with TMT steel bars 8 mm dia @150 mm c/c both ways with suitable handle and angle iron 40x40x5mm frame, GI medium grade watering pipe 20mm bore and funnel with wire mesh light grade protection pipe 40mm bore upto main board complete as shown on electrical plate No 3 of MES Sch 2009 (Part-I) and testing on completion all directed. Note: On testing after completion of earthing, if desired earth resistance is not obtained, the earthing will be re-done by the contractor at his own risk & cost to the entire satisfaction of Engineer-in-charge.
Supply and fixing in replacement CABLOFIL wire meshed stainless steel (SS304) cable tray 54mm (h) x 400 mm (w) complete with nuts bolts washers (GI) and all accessories for mounting and supporting the cable tray system, along with vertical bends, bends. Make- Legrand/Schneider
Material and labour for hiring of Fault locating Machine mounted on Vehicle along with auxiliary power supply required for Installing of equipments connected to FLC Machine along with necessary manpower and T&P for finding out fault in cable HT (11KV) / LT (1000 Volts) by using Ultra sound technique. Complete all as specified and as directed by Engr-in-Charge. Note:1. Contractor shall bear all the cost incurred in arranging FLC machines along with permission of digging in case of land belonging to other than MES/Defence. 2. Penalty for non arranging the FLC machine is 500 per hour after six hours from getting the information either from GE, Engr-in-Charge or concerned JE verbally or telephonically.
CHINAR CONSTRUCTION TRADERS
M/S LEO TRADERS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .