EE RED Sitapur
Vikas Bhawan, Sitapur
Construction of a hall in Community Health Centre Biswan, Block- Biswan
2026_REDUP_1116711_1
1563/RED/Tender/2025-26
Open Tender
Civil Works
90 days
Biswan
Please refer Tender documents.
2 documents required · 2 mandatory
₹944
₹50,000
4 May 2026
16 Feb 2026
21 Feb 2026
16 Feb 2026
21 Feb 2026
16 Feb 2026
Clearing jungles including uprooting of rank vegetation, grass, blush wood, trees and saplings of girth upto 30 cm measured at a height of 1 m above ground level and removal of rubbish upto a distance of 50 m outside the periphery of the area cleared. As per PWD-2.31
Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, for all lift, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. DSR-2.8.1
Treatment of soil under existing floors using chemical emulsion @ one litre per hole, 300mm apart i/c drilling 12mm diameter holes and plugging with cement mortar 1:2 (1 cement : 2 coarse sand) to match the existing floor with Chlorpyriphos/Lindane E.C. 20% with 1% concentration. as per PWD-2.35.3
Sand filling in plinth under floor i/c watering and ramming i/c lift up to 1.50m and lead 50 m as per PWD-2.27
Providing and laying in cement concrete 1:4:8 (1 cement:4 coarse sand:8 stone ballast 40 mm size) and curing complete. As per PWD-4.1.8
Earth filling available excavated earth (excluding rock)in tranches, plinth,sides of foundation etc. in layars nat exceeding 20cm in depth , consolidating each deposited layer by ramming and watering,lead up to 50 m and lift upto 1.5 m i/c all DSR No-2.25 with 5.0 km cartage.
Brick work wthi common burnt clay (non modular) bricks of class -150 in foundation and plinth with (1:4) cement and C/ sand mortar i/c all as per DSR No-6.1.1
R.C.C. work in 1:1.5:3 with Cement, C/s sand and 20mm gauge stone grit in column footing. As per PWD-5.1.2
R.C.C. work in 1:1.5:3 with Cement, C/s sand and 20mm gauge stone grit in column upto floor V level. As per PWD-5.2.2
R.C.C. work in 1:1.5:3 with Cement, C/s sand and 20mm gauge stone grit in column & T beam upto floor V level. As per PWD-5.3
R.C.C. work in 1:1.5:3 with Cement, C/s sand and 20mm gauge stone grit in slabs upto floor V level. As per PWD-5.3
R.C.C. work in 1:1.5:3 work Cement, C/sand and 20mm gauge stone grit in lintel & sunshades upto floor V level. As per PWD-5.3
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more. DSR 5.22.6
M-150 Class Brick work in 1:6 work cement and C/sand mortar in super structure in one brick thick wall upto floor V level. As per PWD-6.4.2
Providing and fixing M.S. Tubular frames for doors, windows, ventilators and cupboard with rectangular/ L-Type sections, made of 1.60 mm thick M.S. Sheet, joints mitred, welded and grinded finish, with profiles of required size, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer. Fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of C.C. 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) DSR 10.15.1
Fixing of Steel or wooden Door chaukhat (above 1.5sqm and upto3.00 sqm) in position etc as per NBO 11.14 (a) (As per SOR 01.07.2014 Bahraich) 4% Vat Less (83.75-4%=80.40) D1,D2,,
Fixing of Steel or wooden Window chaukhat upto1.50 sqm) in position etc as per NBO 11.14 (b) (As per SOR 01.07.201 Bahraich ) 4% Vat Less (67-4%=64.32), W
Fixing of Steel or wooden Ventilator chaukhat in position etc as per NBO 11.14 (c) (As per SOR 01.07.2014 Bahraich) 4% Vat Less (40-4%=38.40) V
S/F of flush doors commercial quality conforming to I.S. 2202 Part 1 (1983) including fixing of woodencleats and stoppers and including fixing and adjustment of hings bolts locks handles springs fitting with necessary screws complete. As per PWD-9.21.1 -35 mm thick
Providing & fixing oxidized M.S. sliding door bolts ISI marked with nuts and screws etc complete (300mm x 16mm). As per PWD-9.62.1
Providing & fixing oxidized M.S. tower bolts ISI marked with nuts and screws etc complete (300mm x 10mm). As per PWD-9.63
Providing & fixing oxidized M.S. Door Handle ISI marked with nuts and screws etc complete (125mm). As per PWD-9.66.1
Providing & fixing oxidized M.S. Pressed butt hinges bright finished ISI marked with nuts and screws etc complete (125x65x2.12mm). As per PWD-9.55.1
Providing 40x5mm flat iron hold fast 40cm long i/c fixing to frame with 10mm diameter bolts ,nuts and wooden plugs and embedding in c.c. block 30x10x15 mm in 1:3:6 ratio as per D.A.R. NO-9.53
P/L in position in C.C specified grade excluding the cost of centering, shuttering ,finishing and reinforcement ( 1:1.5:3)with cement , coarse sand and 20mm gauge stone ballast i/c all as per DSR No- 5.1.2
Supply an fixing glass pans of 4mm thick glass equuivelent ISI mark quality putty brades and springs and i/c all comp. As per PWD-12.47
12 mm thick cement, sand plaster in 1:6 cement & C/sand mortar as per PWD-13.4.2
15 mm thick cement, sand plaster in 1:6 cement & C/sand mortar as per PWD-13.5.2
Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joint with white cement & matching pigments etc. complete. Size of Tile 600x600 mm. As per PWD-11.46.2
Providing and Applying white cement based putty average thickness of 1 mm of approved brand over the plasterd wall surface.as per CPWD-13.80
Painting steel work with deluxe multi surface paint to give an even shade two or more coat applied as per incl. material,labour and T&P etc. required for proper completion of work, as per CPWD-13.48.2
Add for drip course/groove in plastered surface or moulding to R.C.C. projections DSR 5.30
40MM thick cement flooring with concrete hardener topping under layer 40mm thick cement concrete 1;2;4 cement, c/s and 40mm stone gritt as per pwd dsr no- 11.3
Supply and fixing glass strips 22 mm wide 2.8 to 3.7 mm thick as per kanpur sor ch.no-1 item no-15A
Engraving Lines in the plaster of outer face wall vertically and horizontally to display the surface as stone facing as directed by the E/I including all labour and T&P etc. required for proper completion of the work. As per PWD-598 (2020
Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade. New work (Two or more coats applied @ 1.43 ltr/ 10 sqm. over and including priming coat of exterior primer applied @ 2.20 kg/ 10 sqm). As per PWD-13.47.1
Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gram/litre, of approved manufacturer and of required shade and colour all complete to achieve even shade and colour New work (two or more coats) over and including water thinnable priming coat with cement primer having VOC content less than 50 gram/litre DSR 13.41.1
Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes. 110 mm diameter DSR 12.41.2
Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion. Bend 87.5° 110 mm bend DSR 12.42.5.2
Making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate of 20 mm nominal size) over P.V.C. sheet 1 m x1 m x 400 micron, finished with 12 mm cement plaster 1:3 (1 cement : 3 coarse sand) and a coat of neat cement, rounding the edges and making and finishing the outlet complete. DSR 12.22
Supply & Fixing of fan hooks 150 mm dia hexagonal for roof. Elec S.O.R. 2018 S.No.-1149
Providing and laying "brick coba" 12mm thick laid with M-150 class brick bat coba 7.50cm thick with gap of 15mm to each other, over 20 mm thick base of cement mortar 1:4 cement and coarse sand mixed with water proofing compound spreading cement slurry mixed with acrelic cement concrete water proofing compound filled gaps of coba & top of coba mortar mixed with water proofing compound in 1:4 cement and coarse sand mortar finised smooth & top mashed false square 30 cm x 30 cm and side wall parapet shall be mono tythic plaster wall up to 30 cm higher and junction and corner shall be rounded by brick ballast cement and coarse sand masonany Coba with top finised plaster mixed with acetic water proofing compound @ 2% by weight & including s/o all material, labour, T& P etc complete for proper completion of work. 22.7.1
Centering & shuttering including strutting, propping etc. and removal of form for As per PWD Ch-5 D.A.R.-5.9.1
Centering & shuttering including strutting, propping etc. and removal of form for As per PWD Ch-5 D.A.R.-5.9.6
Centering & shuttering including strutting, propping etc. and removal of form for As per PWD Ch-5 D.A.R.-5.9.5
Centering & shuttering including strutting, propping etc. and removal of form for As per PWD Ch-5 D.A.R.-5.9.3
Wiring point for light with 1sq mm PVC insulated single core copper conductor cable in PVC condute with 1.5 sq mm FR PVC Complet in all respect SI No. 131 (C)
Wiring point for fan/fresh air fan (lisht duty exhaust fan)with 1sq mm PVC insulated single core copper conductor cable in PVC condute with 1.5 sq mm FR PVC Complet in all respect SI No. 133 (C)
Wiring point for plug with 1sq mm PVC insulated single core copper conductor cable in PVC condute with 1.5 sq mm FR PVC Complet in all respect SI No. 134 (C)
S/F of switch box made up of 16 SWG (1.5 mm) thick M.S. Sheet of 200x250x65mm size duly painted with red oxide primer require for proper completion of work. SI. No. 162
S/F of surface / flush mounting 8 ways S.P.N. Distribution board without MCB complete in all respect SI No. 1024 cat-b
S/F of power plug 20 A/ 250 V flush type switch and 5 pin 20 A/ 250V flush type universal socket in sutaible M.S. Box of 175x100x65 mm complete in all respect SI No. 1139 A
S/W submain with two number 2.5 sqmm FR PVC insulated 1100V grade multistrand single core copper conductor cable complete in all respect SI No. 1304 (C)
S/W of LED tube light with batten suitable for up 1x22 watt LED tube light complete in all respect SI No. 1413 AAA
S/F of Fan
S/F Of information signboard
Add 18% GST
Please Enable Macros to View BoQ information
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.65 MB
sbd1563.pdf
Tender Documents • 3.81 MB
BOQ_2074189.xls
BOQ • 0.31 MB
Download all tender documents and submit your bid