Clause Regarding GST: (a) All the Bidders/tenderers should ensure that they are GST Compliant and their quoted tax Structure are as per GST LAW.(b) Tenderer Should Furnish their GSTIN numbers representing the States in Which they are registered GST, along with address of Registered Office.(c)The Contract is under GST Act and rules as applicable time to time.
I/we the tenderer (s) am/are signing this document after carefully reading the contents.
I/We the tenderer(s) also accept all the conditions of the tender and have signed all the pages in confirmation thereof.
I/we hereby declare that I/we have downloaded the tender documents from Indian Railway website www.ireps.gov.in . I/we have verified the content of the document from the website and there is no addition, no deletion or no alteration to the content of the tender document. In case of any discrepancy noticed at any stage i.e. evaluation of tenders, execution of work or final payment of the contract, the master copy available with the railway Administration shall be final and binding upon me/us.
I/we declare and certify that I/we have not made any misleading or false representation in the forms, statements and attachments in proof of the qualification requirements.
I/We also understand that my/our offer will be evaluated based on the documents/credentials submitted along with the offer and same shall be binding upon me/us.
I/We declare that the information and documents submitted along with the tender by me/us are correct and I/we are fully responsible for the correctness of the information and documents, submitted by us.
I/we certify that I/we the tenderer(s) is/are not blacklisted or debarred by Railways or any other Ministry / Department of Govt. of India from participation in tender on the date of submission of bids, either in individual capacity or as a HUF/ member of the partnership firm/LLP/JV/Society/Trust.
I/we understand that if the contents of the certificate submitted by us are found to be forged/false at any time during process for evaluation of tenders, it shall lead to forfeiture of the Bid Security and may also lead to any other action provided in the contract including banning of business for a period of upto two year. Further, I/we and all my/our constituents understand that my/our offer shall be summarily rejected.
I/we also understand that if the contents of the certificate submitted by us are found to be false/forged at any time after the award of the contract, it will lead to termination of the contract, along with forfeiture of Bid Security/Security Deposit and Performance guarantee and may also lead to any other action provided in the contract including banning of business for a period of upto two year.
I/We have read the clause regarding restriction on procurement from a bidder of a country which shares a land border with India and certify that I am/We are not from such a country or, if from such a country, have been registered with the competent Authority. I/We hereby certify that I/we fulfil all the requirements in this regard and am/are eligible to be considered (evidence of valid registration by the competent authority is enclosed)
38 conditions · 8 needing a document upload
Check List: The tenderer(s) would fill up the check list, as per Annexure-XXIII to ensure that they are submitting the complete tender offer.
Please enter the percentage of local content in the material being offered. Please enter 0 for fully imported items, and 100 for fully indigenous items. The definition and calculation of local content shall be in accordance with the Make in India policy as incorporated in the tender conditions.
(i) AT NSBG- Electrical work for Provision of additional line in connection with goods loading and unloading facility (ii) Electrical Work for Provision of modern signages at 04 nos ABSS station under NLP section over Tinsukia division (NLP, DMC, SPTR & MZS).
LV-T-14-TSK-956
LV-T-14-TSK-956
Open
Works - General
14 Months
Tinsukia, Assam
₹0
₹76,900
28 Jul 2026
28 Jul 2026
5 Aug 2026
52 items across 2 schedules
| # | Description | Unit | Qty | Rate | Amount |
|---|---|---|---|---|---|
| — | — | — | 20,42,680 | ||
| — | 30.00 | — | — | ||
| Supply, fitting, fixing, testing & commissioning of wiring materials for concealed type wiring of light point from main/sub-main board to the points by 1.5 mm.sq.single core multi-strand FRLS copper cable through heavy duty PVC pipe complete with modular type switch 6 A, ceiling rose, GI box with suitable modules for fixing switches. | — | — | — | 19,620 | |
| — | 16.00 | — | — | ||
| Supply, fitting, fixing, testing & commissioning of wiring materials for concealed type wiring of Fan Point/Exhaust fan point from main/sub-main board to the points by 1.5 mm.sq.single core multi-strand FRLS copper cable through heavy duty PVC pipe complete with modular type switch 6 A,ceiling rose,Modular GI metal box with suitable modules for fixing switches & Regulators and 1.0 sq mm multistrand FRLS copper Cable in green for earth contuinity wire . | — | — | — | 15,120 | |
| — | 14.00 | — | — | ||
| Supply, fitting, fixing, testing & commissioning of Electronic fan Regulator 100 W . | — | — | — | 5,838 | |
| — | 20.00 | — | — | ||
| Supply, fitting, fixing, testing & commisioning of wiring materials for concealed type wiring 5 A plug point from main/sub-main board to the points by 1.5 mm. sq. single core multi-strand FRLS copper cable through heavy duty PVC pipe complete with modular type switch & socket 5 A,GI metal box with Suitable modules for fixing switch/socket with 1.0 mm² unsheathed FRLS copper cable in green colour for earth continuity wire. | — | — | — | 8,560 | |
| — | 8.00 | — | — | ||
| Supply, fitting, fixing, testing & commisioning of wiring materials for concealed type wiring 15 A plug point from main/sub-main board to the points by 4 mm. sq. single core multi-strand FRLS copper cable through heavy duty PVC pipe complete with modular type switch & socket 15 A , GI metal box with Suitable modules for fixing switch/socket with 1.0 mm² unsheathed FRLS copper cable in green colour for earth continuity wire. | — | — | — | 9,840 | |
| — | 30.00 | — | — | ||
| Supply, fitting , fixing of surface mounted LED Batten 20W, 4 Ft, ultra slim co- extruded polycarbonate channel with integrated electronic driver should be as per IEC: 62384/IS:16104( SMPS based constant current output, THD<20%), IP20 protection, color temperature=6500K, rated input voltage=230V AC, 50 Hz, power factor=0.9, view angle>=120°, lumens output not less than 100 lm/Watt, operating voltage range: 140-270 V AC. LED Should be as per LM-80/IS:16105. Fixture Size:(LXWxH=1156x25x35 mm +/-1) . | — | — | — | 7,530 | |
| — | 270.00 | — | — | ||
| Supply, drawing and connection of single core 6 sq. mm PVC insulated & unsheathed multistrand FRLSH copper cable conforming to IS: 694 for voltage grade upto 1100 Volts , as per direction of supervisor incharge at site. | — | — | — | 22,950 | |
| — | 270.00 | — | — | ||
| Supply, drawing and connection of single core 4 sq. mm PVC insulated & unsheathed multistrand FRLSH copper cable conforming to IS: 694 for voltage grade upto 1100 Volts , as per direction of supervisor incharge at site. | — | — | — | 15,390 | |
| — | 360.00 | — | — | ||
| Supply, drawing and connection of single core 2.5 sq. mm PVC insulated & unsheathed multistrand FRLSH copper cable conforming to IS: 694 for voltage grade upto 1100 Volts , as per direction of supervisor incharge at site. | — | — | — | 14,040 | |
| — | 2.00 | — | — | ||
| Supply, fitting, fixing, testing & commissioning of wall mounted type 6 way double door SPN MCB DB having IP 43 protection,Shrouded Neutral Bar & Bus Bar, Cement Spill Protector & Door Earthing with the following domestic switchgears:- :- i) 240/415V, 50Hz, 10kA BC "C" series SP 32 Amps. MCB (In accordance with IS/IEC 60898-1) = 2 No. ii) 240V, 50Hz, with 10kA BC "C" series SP 16 Amps. MCB (In accordance with IS/IEC 60898-1) = 2 Nos. (iii) 240V, 50Hz, with 10kA BC "C" series SP 10 Amps. MCB (In accordance with IS/IEC 60898-1) = 2 Nos. | — | — | — | 7,500 | |
| — | 1.00 | — | — | ||
| Supply, installation, testing and commissioning of VTPN Distribution Board System type 4 way double door, IP 43 Protection with MCCB as incomer with the following switchgears: (i) MCCB, 4 pole, 100 Amps, 16 KA BC= 1 No (ii) MCB , SP, 63 Amps, 'C' series=4 Nos. (iii) MCB, SP, 32 Amps, 'C' series=3 Nos | — | — | — | 31,000 | |
| — | 2.00 | — | — | ||
| Supply, fitting, fixing of exhaust fan 300 mm sweep metallic louver type | — | — | — | 5,120 | |
| — | 150.00 | — | — | ||
| Supply, laying , connection , testing and commissioning of LT XLPE Insulated, Cores Laid Up, PVC Inner sheathed, Armoured stranded aluminum conductor cable size 70 mm.sq. 4 core having Galvanized steel Strip, Extruded PVC Type ST2 Sheathed, 650/1100V Grade As Per IS 7098(Part 1) 1988.For laying of above cable digging of trench and excavation of earth/concrete to depth 0.75 Mtrs. and breadth 0.5 Mtrs. below the ground level and a layer of sand of 0.075 Mtrs. thickness shall be spread over the ground before laying the cable and the cable shall be covered with a layer of sand of 0.075 Mtrs. thickness. The bottom of cable trench shall be leveled and got rid of any sharp material. The cable route markers should be provided along the route of cables to indicate their presence so that damage/accident are Not caused by inadvertent digging.All conditions to be fulfilled as per DRG No : PCEE/ELG/DRG/2024/2 Dtd 04.10.2024. | — | — | — | 2,19,750 | |
| — | 400.00 | — | — | ||
| Supply, laying, connection, testing and commissioning of LT XLPE Insulated, Cores Laid Up, PVC Inner sheathed, Armoured stranded aluminum conductor cable size 25 mm.sq. 4 core having Galvanized steel Strip, Extruded PVC Type ST2 Sheathed, 650/1100V Grade As Per IS 7098(Part 1) 1988. For laying of above cable digging of trench and excavation of earth/concrete to depth 0.75 Mtrs. and breadth 0.5 Mtrs. below the ground level and a layer of sand of 0.075 Mtrs. thickness shall be spread over the ground before laying the cable and the cable shall be covered with a layer of sand of 0.075 Mtrs. thickness. The bottom of cable trench shall be leveled and got rid of any sharp material. The cable route markers should be provided along the route of cables to indicate their presence so that damage/accident are Not caused by inadvertent digging.All conditions to be fulfilled as per DRG No : PCEE/ELG/DRG/2024/2 Dtd 04.10.2024. | — | — | — | 2,95,200 | |
| — | 2.00 | — | — | ||
| Supply, fitting, fixing of 200 Amps outdoor type cable junction box, angle frame mounted, dust & vermin proof, complete with rain cap, aluminium basbar of suitable size for TPN, 200 Amps, 415 V made out of 16 SWG CRCA sheet duly painted, Cable Junction Box Size: (lxbxh=450x 450x600 mm). The base of the fedder pillar junction box to be provided with CC foundation of propotion 1:1.5:3( cement, sang,Chips) after connection of Ug cables. | — | — | — | 17,878 | |
| — | 36.00 | — | — | ||
| Horizontal Directional Drilling (HDD) for boring up to 2.6 m depth underneath road/Railway track and supplying, laying and pulling through 150 mm dia HDPE pipe, PN 8, conforming to IS 4984, complete with pilot drilling, reaming, installation of HDPE pipe, jointing, testing, backfilling of entry and exit pits, disposal of surplus earth and restoration of the site, complete in all respects as directed by the Engineer-in-Charge. | — | — | — | 1,28,160 | |
| — | 3.00 | — | — | ||
| — | — | — | 10,79,319 | ||
| — | 1.00 | — | — | ||
| Supply, fitting, fixing, testing and commissioning of of Indoor Type LT panel board. The panel shall be metal-enclosed, free-standing compartmentalized, modular type suitable for Indoor installation. The panel shall be dust and vermin proof and the enclosure shall provide a degree of protection of not less than IP-52. Control panel shall be fabricated out of 14 SWG cold rolled steel plates & properly supported using angles & channels. The whole panel shall be mounted on a base frame made out of suitable structural, preferably ISMC Channels. Joints of any kind in sheet shall be seam welded, all welding slag grounded off and welding pitwiped smooth with plumber metal. All panels and covers shall be properly fitted and square with the frames and holes in the panel correctly positioned. The Panel shall be fully compartmentalised with front and back opening doors.. When compartment door is opened, busbar and cable alley shall be shrouded by barrier plates. All panels shall be provided with suitable cable alley and vertical bus bar alley.Each cable chamber shall have cable entry from bottom and suitable removable gland plates shall be provided for this purpose. The cable chamber shall be provided with suitable supporting arrangement between the gland plate and terminals, in the middle. The cable chamber shall have a minimum width of 300 mm depending upon the outgoing cables. Each chamber shall be provided with a hinged type door opening away from the cable alley and shall be provided with black flowertype thumb screw which shall ensure tight closing. The edges of the door shall be provided with a neoprene rubber gasket to make the compartment dust proof.. The panel shall consists of the following Switchgears:( BUS BAR=250 Amps TPN Aluminium) (i)MCCB 4 pole 250 Amps, 25KA BC Ics=100%Icu , Thermal Magnetic OL & SC Protection=1 NO (ii) MCCB 4 pole 125 Amps 25KA BC Ics=100%Icu , Thermal Magnetic OL & SC Protection-4 Nos (iii) MCB TPN 63 Amps C series-2 No. (iv)LED three phase indication lamp RYB for incoming mains-3 Nos. (v) Digital Voltmeter LED indication with inbuilt selector switch (0-500 V) -1 Sets (vi) Digital Ammeter LED indication with inbuilt selector switch (40-400 Amps) -1 Sets | — | — | — | 96,325 | |
| — | — | — | 18,01,814.3 | ||
| — | 320.00 | — | — | ||
| Supply, fitting, fixing, testing & commisioning of wiring materials for concealed type wiring 5 A plug point from main/sub-main board to the points by 2.5 mm. sq. single core multi-strand FRLS copper cable through heavy duty PVC pipe complete with modular type switch & socket 5 A ,GI metal box with Suitable modules for fixing switch/socket with 1.0 mm² unsheathed FRLS copper cable in green colour for earth continuity wire. | — | — | — | 3,93,600 | |
| — | 12.00 | — | — | ||
| Supply, fitting, fixing, testing and commissioning of wall mounted 4 way MCB SPN DB Double Door having IP 63 protection, Shrouded Neutral Bar & Bus Bar, Cement Spill Protector & Door Earthing with the following domestic switchgears :- (i) 63 Amps DP MCB "C" Series(2 Module), 240/415 V, 50 Hz, 10 kA BC (In accordance with IS/IEC 60898-1) =2 No | — | — | — | 56,880 | |
| — | 1980.00 | — | — | ||
| Supply, drawing and connection of single core 6.0 sq. mm PVC insulated & unsheathed multistrand FRLHS copper cable conforming to IS: 694 for voltage grade upto 1100 Volts , as per direction of supervisor incharge at site. | — | — | — | 3,97,683 |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
HTML
nit.pdf
NIT
GCCACS11_compressed.pdf
ATTACHMENT
AnexxuresSectionVIINew.pdf
ATTACHMENT
TenderDocumentTSK956.pdf
ATTACHMENT
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at [email protected].