GE 881 EWS
GE 881 EWS C/o 56 APO
SPECIAL REPAIR/ REPLACEMENT OF UNSERVICEABLE SECURITY LIGHT AND CONNECTED ITEMS FOR UNITS AT UPPER LOWER GRN MENDHAR UNDER STN HQ BG SPL REPAIR TO BLDG NO T-27 OF ADU AT LOWER GARRISON JWG UNDER GE 881 EWS
2020_MES_373759_3
GE/PNH-24/2020-21
Open Tender
Civil Works
Item Rate
180 days
GE 881 EWS C/o 56 APO
AS PER TENDER DOCUMENTS
8 documents required · 8 mandatory
₹500
GE 881 EWS
₹17,000
Yes
18 Feb 2021
9 Nov 2020
24 Nov 2020
9 Nov 2020
23 Nov 2020
10 Nov 2020
Amount
B&R PORTION:- Dismantling of plain or corrugated steel sheeting, any gauge, thickness including Nainital or similar pattern roof covering, all as specified.
Dismantling wrought iron or mild steel work of any description complete all as specified and directed.
Dismantling of timber scantling under 40sqcm in section unframed work as in fillets, rails, posts, rafters, purlins etc , complete all as specified.
Demolition of cement concrete (un-reinforced) in ground floors and paving not exceeding 15cm thickness (below or above ground level), complete all as specified and as directed.
Taking down cement plaster of any description on stone or brick walls etc including racking out joints, hacking for key scrubbing down with water etc.complete all as specified.
Taking down chowkats or frame with shutters (without taking off shutters from the frames) area not exceeding 1.5Sqm each, complete all as specified.
Taking down chowkats or frames with shutters (without taking off shutters from the frame) area exceeding 1.5Sqm and not exceeding 4Sqm each, complete all as specified and directed.
Demolition of brick or stone masonry, built in cement mortar including all quoins, arches, pillars etc but excluding ashlars facings, dressed stone work, complete all as specified and directed.
Rolled mild steel works as in roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (beam,tee,angle, channel or flat sections) including distance pieces, cleats etc Fe 410W(Gde E-250), quality 'A' complete all as specified.
Rolled mild steel sections as in main and cross beams, hip and jack rafters; purlins where connected to common rafters and running rails and guides for sliding doors; fixed with angle cleats or other connected plate confirming to Fe 410W(Gde E-250), quality 'A' complete all as specified.
Mild steel bands, straps, supports or stays for rainwater, ventilating pipes, including bolts, if required: hooks (stay), heavy, for large gates; hook and pintle hinges: large hasps and staples; chains; hand made sliding bolts; clamps; hold fasts; wall ties; hooks for hanging fans; plain angle cleats for securing purlins to wood trusses or rafters; knee piece inserts; two way and three way straps, plate washers and similar small articles conforming to Fe-290 Gde-E-165 complete all as specified and directed.
Pre- painted galvatume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified.
Pre- painted galvatume aluminum zinc coating GI based plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, valley gutter, ridge & similar works fixed with self tapping screws complete all as specified.
Applying two coats of synthetic enamel paint of Ist quality over a coat of red oxide primer to new or previously untreated steel surfaces over 10cm width or girth including preparation of surfaces, complete all as specified and as directed.
Walling of random rubble stone masonry brought upto course, well bonded, bedded and solidly hearted, built in cement mortar (1:6), complete all as specified and directed.
Description all as per item No.15 above, but except stone complete all as specified and directed.
RCC (nominal mix) 1:1.5:3, type, A-1 (using 20mm graded crushed stone aggregate), as in beams , cantilevers, bressummers, lintel over 1.5 mtr span, complete all as specified.
Form work to sides and soffits of floor or roof beams, beam haunchings , lintels, cantilevers, shelves including supports, overhangs etc and similar works for fair finished surfaces of concrete, complete all as specified.
TMT bars, 10mm dia and over, cut to length, bent to shape required including cranking, bending spirally or hooping for column, hooking ends and binding with and including mild steel wire(annealed) not less than 0.90mm dia complete all as specified.
TMT bars, 6 to 8 mm dia, cut to length, bent to shape required including cranking, bending spirally or hooping for column, hooking ends and binding with and including mild steel wire(annealed) not less than 0.90mm dia as in stirrups, complete all as specified.
75mm thick PCC 1:4:8 type D-2 (using 40mm graded crushed stone aggregate) as in sub base to flooring/path etc, complete all as specified and directed.
Suspended false ceiling using E- grid suspended ceiling grid system of grid size 600x600mm with GI frame work of main runner 38 x 24mm sheet thickness 0.4mm, cross Tee 28 x 24mm sheet thickness 0.3mm and wall angle 24 x 24mm x 0.5mm using 4mm thick high pressure stream cured classic variant E-board, designer pattern (ISI marked, IS No 14862-2000) & E board to be placed in the grid suspended by 4mm GI wire hangers from the purlins of the roof with butter fly clips with & including two coats if distemper oil emulsion, complete all as specified and directed. Make:- Everest Industries Ltd of equivalent as approved by GE.
25 mm thick PCC 1:2:4 type B-0 (using 12.50mm graded crushed stone aggregate) as in sub base floor finishing surface even and fair, complete all as specified.
Non skid coloured ceramic tiles 7 - 8 mm thick area of each tile exceeding 0.18sqm but not exceeding 0.38sqm in floors etc set and jointed in neat cement slurry and pointed in white or coloured cement to match the shed of tiles laid over and including 15mm thick screed bed in CM (1:6), complete all as specified and directed.
Non skid coloured ceramic tiles 7 to 8mm thick (square / rectangular) area of each tile exc 0.18Sqm but n exc. 0.36Sqm in vertical surfaces such as in skirting, dado etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles,fixed over and including 10mm thick plaster in CM (1:4), complete all as specified and directed.
50mm thick PCC 1:3:6 Type C-2 (using 40mm graded crushed stone aggregates) laid in alternate bays (not exceeding 2 sqm each) as in plinth protection, finished the surfaces even & fair, including filled the joints with mastic filling comprising one part of bitumen 85/25 grade and three parts of sand by weight complete all as specified.
Cement concrete (1:2:4) type-B-1 (using 20mm graded stone crushed aggregate) as in lintels upto 1.5 metre clear span, cills, steps, siesmic and other similar bands, plinth courses, string courses, lacing courses, parapets and railing upto 60cm height, copings, bed block, kneelers, apex stones, bed plates, roof kerbs round or chamfered on edges, water troughs and the like including weathering, slightly rounded or chamfered angles and throatings etc.including necessary form work complete all as specified and directed by Engineer-in-Charge.
Plain cement concrete 1:3:6 type C-1(using 20mm graded crushed stone aggregate) as in surface channels and drains, complete all as specified.
Extra for forming fair finished drain or channel 30cm inner girth in cement concrete using extra cement including forms, moulds, mitred/stopper ends etc complete all as specified.
Brick work with sub class ‘B’ bricks straight or curved on plan exc 6m mean radius, built in cement mortar (1:6), all as specified and directed.
15mm thick rendering in CM 1:6 on other than fair faces of brick or stone masonry wall surfaces & finishing the surface even and smooth without using extra cement, complete all as specified.
15mm thick rendering in CM 1:4 on other than fair faces of brick or stone masonry surfaces & finishing the surface even and smooth without using extra cement, complete all as specified.
15mm thick cement plaster rendering in CM 1:4 on fair faces of bricks or concrete surfaces & finishing the surface even and smooth without using extra cement, complete all as specified.
Preparation of newly plastered or unplastered surfaces of wall and applying two coats of cement base paint, complete all as specified.
Preparation of newly plastered surface of wall including cornices pilaster etc, and applying two coats of oil emulsion distemper over and including 1-3mm thick wall care putty, complete as specified and directed.
Factory made Pressed steel frames of size 125x60mm made out of PBI sheet 1.25 mm thick for doors with one or more rebates including necessary fixing lugs, hinge,lock strike plate etc.complete including bottom of each chowkat to be welded with 02 Nos 25x25x3mm thick angle iron projecting 10cm on either side & PCC 1:3:6 type C-0 in back filling of chowkats & tarring back of chowkats and holdfasts complete all as specified & directed.
35mm thick 2nd class hard wood plain, framed, panelled door shutters (any number of panels), with panels of timber flat on both sides (feather edged), or of 12mm thick veneered particle board medium density, wood particle board with commercial face veneers, complete all as specified and directed.
35mm thick 2nd class hard wood Glazed and skelton shutters, open rebated and prepared to receive glass, gauge etc divided into square (with sash bars) edges of framing plain, chamfered or rounded fitted with cut and mitered beads for securing glass etc. size of members of shutters as specified in SSR Part-I, Section 8, clause 8.24 (a) supplied and fitted to chowkats complete, all as specified.
Steel windows or ventilators made out of 1.25mm thick pressed steel frame with glazed & gauged shutters (combination), side hung / top hung type with or without glazing bars as directed including box type / projecting type hinges and steel peg stay, handle, tower bolt & locking arrangement with & including guard bar provided with cooler opening, complete all as specified & directed.
Mild steel butt hinges, medium weight, cold rolled,50mm long, complete all as specified.
Second class hard wood small fittings such as brakets of any type, latch and hinges blocks, shaped doors and windows stops and the like, including all necessary labour, articles not exceeding 200 cu.cm each complete all as specified
300mm Mild steel ordinary rat tail rod pattern springs including roller and roller plate complete all as specified.
Aluminium anodised, barrel tower bolts of extruded section of size 150mm and fixed, complete all as specified and directed.
Aluminium alloy handles, cast type, anodised of size 150mm and fixed, complete all as specified and directed.
250mm long aluminium alloy anodized sliding door with haps, staple (bolt type) and fixing clips of sheets, cast or extrusted sections and fixing bolts and sliding bolts of extruded section or cast aluminium alloy all as specified.
Sheet glass ordinary quality, 3mm thick, glazing with oil putty or wooden beads in squares not exceeding 0.50Sqm in each pane, complete all as specified.
Stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples or wooden beading, complete all as specified.
Preparation of new wooden surfaces of any description, not otherwise described over 10 cm width or girth and applying two coat of synthetic enamel paint of Ist quality over a coat of pink primer,complete, all as specified.
Mild steel butt hinges, medium weight, cold rolled,100mm long, complete all as specified.
E&M PORTION:- Taking down carefully copper/ aluminium unserviceable/ perished point wiring (light, fan, socket or power complete including fixture and fittings such as switches, ceiling roses, pandents, regulators, sockets, light fittings,removing material from site for taking credit etc and making good disturbed surfaces of wall, floors, complete all as specifiecd and directed.
Taking down carefully unsv sub main wiring including earth continuity of any type / size with surface casing caping / TW batten / pvc conduit surface or recess and making good distrubed surface of walls and roofs to match the existing surface, complete all as specified and as directed.
Taking down carefully unsv main switch / DBs alongwith MCBs / wooden board / connected fittings & fixtures any type and making good distrubed surface of walls and roofs to match the existing surface, complete all as specified and as directed. Note:-Old serviceable switches & MCB shall be taken on charge by the MES for reuse and unsv fittings shall be credited to the contractor.
Point wiring with two single core 1.5 Sqmm (nominal cross section area) FRLS PVC insulated unsheathed multistranded copper conductor cable and one single core 1.5 Sqmm (nominal cross section area) FRLS PVC insulated unsheathed multistranded copper conductor cable as earth continuity to common earth and connecting to earth dolly running in and including PVC casing & caping (ISI marked) of suitable size with PVC boards of appropriate sizes and all requisite accessories such as PVC elbow, Tee, collars, bends etc. with PVC terminals box & cover for mounting swtches, sockets, fan regulator etc for mounting switches, sockets, fan regulators etc complete all as specified and as directed for the following :-
One light / fan point controlled by one way switch 6 Amp complete all as specified.
One 3 pin socket outlet 6 amp on same board complete all as specified.
One 3 pin socket outlet 6 amp independent board complete all as specified.
Description all as per srl item No 53 here in before but for one 3 pin socket outlet 16/20 Amp independent with two single core 2.5 Sqmm size cable as phase & neutral and one single core 1.5 Sqmm as in continuous earth wire.
Ceiling rose, 3 phase PVC/poly carbonate, insulated body, compete all as specified.
Switch piano flush type 6 Amp single pole one way, (ISI marked), complete all as specified.
Switch socket multipurpose combination 2 in 1, 5 pin, 5 Amp flush type universal, complete all as specifed.
Switch socket outlet multipurpose combination 2 in 1, 6 pin, 5 and 15 Amp flush type universal,complete all as specifed.
Stepped type electronic fan regulator flush type on the existing phenolic laminated sheet etc. for 1200 / 1400mm sweep, complete all as specified.
Lamp holder PVC/Polycarbonate type with back plate suitable for batten fittings, complete all as specified and directed.
Tube light fitting with universal batten suitable for T8 LED lamps LED 120W tube Rod with end cap complete with hosing with all accessories pre wired and making connection with three core copper flexible cable of size 23/0.0076 from ceiling rose to PVC connection to light fitting including 20LED tube rod 4 feet long (Double Side Connection) complete all as specified and directed. Make:-Havells Cat Part No:-REGALBATTENT8UPTO1X22WSSBSWH for fittings & CRYSTAL 1213T8DSTL20WLED865SGLASS for LED tube rod or Equivalent cat part of make as specified in Appx 'A' here in after. Note :- The LED batten and LED tube rod shall be of same make.
Sheet metal enclosure factory made (Double door) for DBs, single pole and neutral, 240 volts, 4 way with 200Amps rated bus bar fixed on walls, including connecting both incoming and outgoing cable termination with proper taping, lagging testing and commissioning fixed in repairs, complete all as specified. Make:- Havells cat part No-DHDPSHODPW04 or Equivalent cat part of make as specified in Appx 'A' here in after.
MCB single pole & neutral 40-63 amps 240 volts 10 KA 'C' series fixed, complete all as specified. Make:-Havells cat part No-DHMGCSNF040-063 or Equivalent cat part of make as specified in Appx 'A' here in after.
MCB single pole 6 to 32 amps 240 volts 10 KA 'C' series fixed in repair, complete all as specified. Make:-Havells cat part No-DHMGCSPF006-032 or Equivalent cat part of make as specified in Appx 'A' here in after.
Sub main wiring with single core cable 2 x 4 sq mm FRLS insulated unsheathed stranded copper conductor cable 1100 Volts grade including steel conduit painted black / PVC casing caping with holding clamps & screws alongwith 1x 2.5 Sq mm FRLS insulated unsheathed copper conductor cable as earth wire connected with main earth dolly including taking down old unsv sub main wiring of any type, complete all as specified and directed. Note:-2 wire of 4sqmm, 1 wire of 2.5 sqmm and one run of steel conduit / PVC casing caping shall be measured as one unit.
Supply and laying or fixing or passing through pipe 1100 volts grade heavy duty electric cable with XLPE insulated screened PVC bedded aluminium stranded conductor served with inner sheathing of PVC tape armoured with galvanised steel wire or tape and over all PVC sheathed of size 16 Sqmm x 2 core with & including taking down old unsv xlpe cable, complete all as specified.
Excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5 m in depth in any type of soil for taking out or laying of under ground cable, complete all as specified and directed.
Returning, filling in, including spreading, leveling, watering and well ramming in layers not exceeding 25cm, in any type of soil, complete all as specified and as directed.
Removing excavated material (soil) not exceeding 50m and deposition where dircted at a level not exceeding 1.50m above the starting point, all as specified and directed.
Dry sand cushioning to UG cable 8 cm thick before laying and 15cm thick after laying complete all as specified and directed. Note:- 1.Dry fine sand of best available quality shall be used. 2.Punned thickness shall be made and paid.
Supply and laying sub class `B` bricks laid dry flat transversely along the length of cable with width equal to the length of bricks over sand cushioning as protection cover of cable laid, complete all as specified and directed.
GI pipe light grade 40 mm bore for cable protection fixed on poles or laid in trenches, under floor, ducts etc with fixing clamps of required size, nuts, bolts, washers etc. fixed, complete all as specified.
Earthing complete with galvanized steel earth plate electrode 60cmx 60cmx6mm thick buried directly in ground (earth pit not less than 2.25m deep below normal ground level) with top edge of the plate not less than 1.5m below normal ground level, connected to galvanized iron wire 4.0mm dia by means of bolts, nuts and washers of galvanized iron or steel, protected by GI light grade pipe 15mm bore including GI light grade water pipe 20mm dia with funnel all as shown in electric plate No. 3 of 2009 SSR Pt-I and testing complete including earth work in any type of soil, PCC 1:2:4 type B-1 as in earthing pit and cover 50mm thick reinforced with 8mm dia MS round bar @ 10cm C/C both way and MS frame, common salt, charcoal and testing on completion including dismantling unsv earthing, complete all as specified and directed.
LED street light fittings 45 Watt made up of pressure die cast aluminium housing with high power LED as lighting source and lens embedded PC cover having TOP opening seperate driver compartment complete with hosing with all accessories pre wired and making connection with 3 core copper flexible cable of 1.5sqmm size to light fitting with & including taking down old unsv street light fittings, complete all as specified and directed. Make:-Havells Cat Part No:-ENDURAPEARLNEOSL45WLED757PASYTOPC or Equivalent cat part of make as specified in Appx 'A' here in after.
GI pipe street light bracket light grade 40mm bore 1.5mtr long bent to shape as directed with two number of flat iron clamps made out of mild steel flat iron 40x6mm with 16mm dia bolts with nuts and washers fixed on steel pole / PCC pole / wall duly painted with two coats of aluminium paints with & including taking down old unsv bracket, complete all as specified and directed.
FRP pole mounting box weather proof out door type junction box of size 250mm x 150mm x100mm with three terminal and one 6 Amps SP MCB-01 No (make:-L&T/LEGRAND/ABB), easy openable and having locking arrangement including incoming and out going cable holes with fixing MS clamp and water tight polymide cable gland for each connection with & including taking down old unsv junction box, complete all as specified and directed.
MS clamps (suitable for holding street light bracket on steel pole / PCC pole) made out of flat iron 40x6mm with 10mm dia 50mm long bolts with nuts and washers fixed on steel pole / PCC pole / wall-02 Nos on each bracket duly painted with two coats of aluminium paints with & including taking down old unsv clamps, complete all as specified and directed.
M/S BHATT TRADERS
M/S Farooq Ahmed Bhat
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .