| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹17.4 LAccepted-AOC BUNGLOW NO 1 RAJPOOT VILLA BARARU ROAD PATKUYI BARARU SAGAR MP 470002 | SAGAR | SAGAR | MADHYA PRADESH | 470002 | L1 | Accepted-AOC AOC | |
| 2 | L2₹18.1 L+₹76,101 (4.38%)Rejected-Finance 00 SHOP NO 28 ABANTI BAI MARKET MAKRONIYA SAGAR MADHYA PRADESH 470004 | SAGAR | MADHYA PRADESH | 470004 | L2 | Rejected-Finance Not Lowest Bidder | |
| 3 | L3₹20.0 L+₹2.6 L (15.1%)Rejected-Finance 1442 1 NANADANPURA BABINA CANTT TEHSIL DISTT JHANSI UP | BABINA | JHANSI | UP | L3 | Rejected-Finance Not Lowest Bidder | |
| 4 | L4₹20.7 L+₹3.3 L (19.2%)Rejected-Finance SNEH NAGAR COLONY NEAR ABKARI OFFICE SHIVAJI WARD SAGAR MP 47000 | SAGAR | SAGAR | MP | 47000 | L4 | Rejected-Finance Not Lowest Bidder |
Tender Value
₹22 L
EMD Value
₹44,000
Closing Date
13 Feb 2024, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GARRISON ENGINEER SAUGOR
Military Engineer services Garrison Engineer Saugor MP- 470001
Repair and maint of summer appliances with connected accessories under GE Saugor.
2024_MES_637864_1
GE/SGR/TOK-67 OF 2023-24
Open Tender
Miscellaneous Works
Item Rate
330 days
Saugor
Class E category c (i) and as per tender documents
6 documents required · 6 mandatory
₹500
GARRISON ENGINEER SAGAR
₹44,000
Yes
11 Mar 2024
17 Jan 2024
15 Feb 2024
17 Jan 2024
13 Feb 2024
1 Feb 2024
18 Jan 2024 - 26 Jan 2024
Amount
AIR CONDITIONER (SPLIT/WINDOW/WALK-IN-COOLER) Carry out day to day complaint rectification and periodical service maintenance as per manual recommendation at Area I & Area II like testing of gas leakege from line any Capacity, replacement of defective any capacity of capacitor/Condensor, any size of Copper tube alongwith insulation pipe, drain out pipe, Cooling fan & cooling fan motor and cooling coil ,Compressor, air filter, Swing motor, over load relay, PVC grill, PCB circuit board along with remote control, Condensor motor & fan blade , industrial metal plug top and bottom, Plug nut, Suction pipe, Charging Gas, Testing of gas leakeage using nitrazen gas, Cleaning of the Filters, checking control Wiring , etc., complete all as directed by the Engineer-in-Charge Note: (i) . Replacement of Spares and fitting shall be measured and paid separately as Supply only.(ii) If required shifting of Split /Window AC shall be measured and paid separtely. (iii). Petty stores such as insulation tape, screws, small pieces of wires,plug top etc shall be provided by the Contractor without any extra cost to the department (iv). AC Mechanic along with Helper so detailed by the contractor will report to MES complaint cell at 08.45 Hrs morning to receive complaints(Complaint slip provided by the contractor) from department and complaint should be rectified with in a same day. (v). Rate included with transport vehicle provided by the contractor to attending the complaints Area I&II .(vi). Attending the complaints not less than min three complaints per day
Supply only following items suitable for AIR CONDITIONER (SPLIT/WINDOW/WALK-IN-COOLER):-
Compressor suitable for window/Split AC of capacity 1.5 Ton Make: GODREJ/L&T/BLUE STAR/WHIRLPOOL/VOLTAS
Compressor suitable for window/Split AC of capacity 2.0 Ton Make: GODREJ/L&T/BLUE STAR/WHIRLPOOL/VOLTAS
Compressor Suitable for Split AC of Capacity 3.0 Ton Make: GODREJ/L&T/BLUE STAR/WHIRLPOOL/VOLTAS
Capacitor of capacity 25 MFD
Capacitor of capacity 30 MFD
Capacitor of capacity 35/36 MFD
Capacitor of capacity 40/45 MFD
Capacitor of capacity 50 MFD
Capacitor of capacity 55/60 MFD
Capacitor of capacity 65 MFD
Capacitor of capacity 30+2 MFD
Capacitor of capacity 30+4 MFD
Capacitor of capacity 35/36+2.5 MFD
Capacitor of capacity 35/36+4 MFD
Capacitor of capacity 35/36+6 MFD
Capacitor of capacity 40/45+2.5 MFD
Capacitor of capacity 40/45+4MFD
Capacitor of capacity 40/45+6 MFD
Capacitor of capacity 50+2.5 MFD
Capacitor of capacity 50+4 MFD
Capacitor of capacity 50+6 MFD
Capacitor of capacity 55/60+2.5 MFD
Capacitor of capacity 55/60+4 MFD
Capacitor of capacity 55/60+6 MFD
Cooling Coil suitable for 1.5 Ton Capacity Window AC
Cooling Coil suitable for 2.0Ton Capacity Window AC
Cooling Coil suitable for 1.5 Ton Capacity Split AC
Cooling Coil suitable for 2.0 Ton Capacity Split AC
Cooling Coil suitable for 3.0 Ton Capacity Split AC
Swing motor suitable for 1.5 Ton Capacity Window type Air Conditioner as per existing sample
Swing motor suitable for 2.0 Ton Capacity Window type Air Conditioner as per existing sample
Swing motor blades suitable for 1.5 Ton Capacity Split type Air Conditioner as per existing sample
Swing motor blades suitable for 2.0 Ton Capacity Split type Air Conditioner as per existing sample
Swing motor suitable for 3.0 Ton Capacity Split type Air Conditioner as per existing sample
Swing motor blades suitable for 3.0 Ton Capacity Split type Air Conditioner as per existing sample
Over load relay suitable for 1.5/2.0 Ton Window type AC
Over load relay suitable for 1.5/2.0 Ton Split type AC
Over load relay suitable for 3.0 Ton Split type AC
PVC Front gril suitable for Window type AC of any Make suitable for 1.5/2.0Ton window AC
AC indoor blower motor fan suitable for 1.5 Ton Capacity Window type AC
All as per Srl item No. 2.41 here in before but suitable for 2.0 Ton Capacity Window type AC
All as per Srl item No.2.41 here in before but suitable for 1.5 Ton Split AC
All as per Srl item No. 2.41 here in before but suitable for 2.0 Ton Split AC
All as per Srl item No. 2.41 here in before but suitable for 3.0 Ton Split AC
Blower motor fan blade suitable for 1.5/2.0 Window type AC
Blower motor fan blade suitable for 1.5/2.0 Split type AC
Blower motor fan blade suitable for 3.0 Split type AC
Condenser motor with fan blade suitable for 1.5 Ton capacity Window type AC
Condenser motor with fan blade suitable for 2.0Ton capacity Window type AC
Condenser motor with fan blade suitable for 1.5 Ton capacity Split type AC
Condenser motor with fan blade suitable for 2.0 Ton capacity for Split type AC
Condenser motor with fan blade suitable for 3.0 Ton capacity for Split type AC
Thermostat switch with knob suitable for AC of any capacity.
Air Filter Suitable for 1.5/2.0/3.0 Ton Capacity Window/Split type Air conditioner
Capillary tube length as per existing size suitable for 1.5/2.0/3.0 Ton Capacity Air conditioner
PCB Circuit with remote control suitable for any make and capacity of 1.5/2.0 Ton Window type AC
PCB Circuit with remote control suitable for any make and Capacity of 1.5/2.0/3.0 Ton capacity split type capacity Air Conditioner .
PCB Circuit with remote control suitable for any make and Capacity of 1.5/2.0 Ton capacity inverter type Air Conditioner
Metal top with bottom suitable for 16 Amps Capacity 1.5/2.0/3.0 Ton Capacity Air conditioner Make: Anchor/Havells/Philips/Polycab and as per site requirement.
Suction/Drain out pipe suitable for 1.5/2.0/3.0 ton capacity Suitable for Air conditioner as per sample
Insulation of size 1/4, 3/8 for Split AC complete as per existing sample
Insulation of size 1/2 5/8 for Split AC complete as per existing sample
Rubber bush suitable for 1.5/2.0/3.0 ton capacity Suitable for Air conditioner as per existing sample
Copper Tube of size 1/4/ 3/8 suitable for any type and any capacity Air conditioner as per existing sample
Copper Tube of size 1/2 /5/8 suitable for any type and any capacity Air conditioner
Plug nut of size 1/4 3/8 suitable for any type and any capacity Air conditioner
Plug nut of size 1/2 5/8 suitable for any type and any capacity Air conditioner
AC indoor AC unit back plate suitable for 1.5/2./3.0 Ton capacity Air conditioner
Power relay Contactor suitable for 1.5 Ton AC
Power relay Contactor suitable for 2.0 Ton AC
Power relay Contactor suitable for 3.0 Ton AC
AC indoor Main board suitable for 1.5 Ton Capacity Air Conditioner
Refrigerent Gas R-22
Refrigerent Gas R-32 ( C)
Refrigerent Gas R-134(a)
NRV Suitable for Any Capacity& any Make Air conditioner
Dry cell 1.5V suitable for Different type of remote as per sample
M&L for preparation of new steel surfaces of any description over 10 cm width or girth and applying two coats of synthetic enameled paint over a coat of red oxide primer complete all as specified and directed.
M&L for dismantling of indoor and outdoor unit and disconnect the electric and gas connection ,cleaning the internal and portion of split AC indoor and outdoor unit checking serviceability transport to new location and fixing the indoor and outdoor unit connect gas and electric connection testing and commissioning complete all as specified and directed arge. Note:- (i) Rate shall be deemed included for outdoor stand, copper tube alongwith insulation,cable as per site requirement any size any length.point wiring shall be measured separately. (ii) Rate shall be deemed included for M&L for making good the disturbed wall portion during installation/shifting of AC by using plaster of Paris material and finishing to match with the existing surface
WATER COOLER Carry out day to day rectification any Make,any capacity of Water Cooler complaints at Area I & Area II like testing of gas leakege from line any Capacity, replacement of defective any capacity of capacitor/Condensor, any size of Copper tube , drain out pipe, Cooling fan & cooling fan motor and cooling coil ,Compressor, over load relay, GI grill, , industrial metal plug top and bottom, Suction pipe etc., complete all as directed by the Engineer-in-Charge Note: (i) . Replacement of Spares and fitting shall be measured and paid separately as Supply.(ii) If required shifting of Water cooler shall be measured and paid separtely. (iii). Petty stores such as insulation tape, screws, small pieces of wires,plug top etc shall be provided by the Contractor without any extra cost to the department (iv).Water cooler Mechanic along with Helper so detailed by the contractor will report to MES complaint cell at 08.45 Hrs morning to receive complaints(Complaint slip provided by the contractor) from department and complaint should be rectified with in a same day. (v). Rate included with transport vehicle provided by the contractor to attending the complaints Area I&II .(vi). Attending the complaints not less than min three complaints per day
Supply only following items suitable for WATER COOLER:-
Compressor suitable for 60/120 Water cooler capacity
Compressor suitable for 40/80 Water cooler capacity
Compressor suitable for 150/150 Water cooler capacity
Compressor suitable for 40/40Water cooler capacity
Compressor suitable for 150/180 Water cooler capacity
Starting Capacitor suitable for compressor of water cooler 150/180,60/120 and 40/80 capacity
Running Capacitor suitable for compressor of water cooler 150/180,60/120 and 40/80 capacity
Starting relay current type suitable for compressor of water cooler 150/180,60/120 and 40/80 capacity
Over load Protector suitable for compressor of water cooler 150/180,60/120 and 40/80 capacity
Thermostat switch with knob suitable for compressor of water cooler 150/180,60/120 and 40/80 capacity
PVC float valve assy alongwith ball with complete accessories for water cooler any capacity of size 15 mm dia . Make: Prayag/waterman/leader or equalvent
Self closing water tap 15 mm dia chromium plated inner/outer thread for water cooler 150/180,60/120 and 40/80 capacity as per sample Make: Waterman/Leader
Air Filter Suitable for water cooler 150/180,60/120 and 40/80 capacity
Capillary tube of suitable length as per existing size for water cooler 150/180,60/120 and 40/80 capacity
PVC Drain out pipe as per sample
PVC Flexible extension pipe 15 mm dia , Make Prayag/V Guard/Leader
Cooling Coil suitable for 150/180,60/120 and 40/80 capacity Water Cooler
Cooling coil Motor suitable for 150/180,60/120 and 40/80 capacity Water Cooler
Cooling coil Motor fan blade suitable for 150/180,60/120 and 40/80 capacity Water Cooler
Sheet metal enclosures with flush mounted type plug and socket with 240 V SP MCB 20 Amps Capacity Make: ABB/Legrand/Havells
M&L for water cooler Stainless storage tank brazing/welding of damage/crack portion and making good condition including replacement of Bolt,nut with washers and testing complete all as directed
REFRIGERATOR Carry out day to day rectification any Make,any capacity of Refrigerator complaints at Area I & Area II like testing of gas leakege from line any Capacity, replacement of defective any capacity of capacitor/Condensor, any size of Copper tube , drain out pipe, Cooling fan & cooling fan motor and cooling coil ,Compressor, over load relay, Vegitable tray, Magnetic gasket, Freezer, PVC Plug top and bottom, etc., complete all as directed by the Engineer-in-Charge Note: (i) . Replacement of Spares and fitting shall be measured and paid separately.(ii) If required shifting of Refrigerator shall be measured and paid separtely. (iii). Petty stores such as insulation tape, screws, small pieces of wires,plug top etc shall be provided by the Contractor without any extra cost to the department (iv).Refrigrator Mechanic along with Helper so detailed by the contractor will report to MES complaint cell at 08.45 Hrs morning to receive complaints(Complaint slip provided by the contractor) from department and complaint should be rectified with in a same day. (v). Rate included with transport vehicle provided by the contractor to attending the complaints Area I&II .(vi). Attending the complaints not less than min three complaints per day
Supply only following items suitable for REFRIGERATOR:-
Compressor suitable for 195to 210 Ltrs Capacity Refrigerator
Compressor suitable for 225 to 250 Ltrs Capacity Refrigerator
Compressor suitable for 260 to 310 Ltrs Capacity Refrigerator
Magnetic door gasket suitable for 165 to 200 ltrs capacity Refrigerator as per sample
Magnetic door gasket suitable for 286/320 Ltrs capacity Refigerator as per sample (Double Door)
Freezer suitable for 165 to 200 ltrs capacity Refrigerator
Freezer suitable for 286/310 Ltrs capacity Refigerator
Relay current type and over load protector suitable for compressor complete Make: Ranutrol/Voltas/LG
Thermostat auto defrost type suitable for any make and any capacity Refrigerator
Air Filter suitable for for any make and any capacity Refrigerator
Capillary tube of suitable length as per existing size for refrigerator any make and any capacity
Vegitable tray with Glass cover and bottle rack as per sample and suitable for refrigertator any type and any make
PVC Stand for Refigerator capacity any make and any capacity as per sample
PVC top 16 Amps Suitable for any capacity and any make Refrigerator as per sample
PVC Nylon Roller as per sample
Contensor Coil suitable for any model and capacity Refrigerator as per sample
Evaporator Coil suitable for any model and capacity Refrigerator as per sample
Expansion valve suitable for any model and capacity Refrigerator as per sample
DEEP FREEZER Carry out day to day rectification any Make,any capacity of Deep Freezer complaints at Area I & Area II like testing of gas leakege from line any Capacity, replacement of defective any capacity of capacitor/Condensor, any size of Copper tube , drain out pipe, Cooling fan & cooling fan motor and cooling coil ,Compressor, over load relay, Magnetic gasket, PVC Plug top and bottom, Door Lock, MS Hings, Trolley Nylon roller alingwith bracket etc complete all as directed by the Engineer-in-Charge Note: (i) . Replacement of Spares and fitting shall be measured and paid separately.(ii) If required shifting of Deep Freezer shall be measured and paid separtely. (iii). Petty stores such as insulation tape, screws, small pieces of wires,plug top etc shall be provided by the Contractor without any extra cost to the department (iv). Deep Freezer Mechanic along with Helper so detailed by the contractor will report to MES complaint cell at 08.45 Hrs morning to receive complaints(Complaint slip provided by the contractor) from department and complaint should be rectified with in a same day. (v). Rate included with transport vehicle provided by the contractor to attending the complaints Area I&II .(vi). Attending the complaints not less than min three complaints per day
Supply only following items suitable for DEEP FREEZER:-
Compressor Suitable for 300 Ltrs Capacity Deep Freezer
Compressor Suitable for 500 Ltrs Capacity Deep Freezer
Relay current type and over load protector suitable for compressor
Thermostat auto defrost type suitable for any make and any capacity Deep Freezer Make: Danfos/Ind Foss/Renutrol
Drier filter complete set suitable for any make and any capacity Deep Freezer
Indicating lamp (Red and Green) 230V complete suitable for any make and any capacity Deep Freezer as per sample complete
Capillary tube of suitable length as per existing size for Deep freezer any make and any capacity
Starting relay suitable for 310/320 ltrs capacity Deep freezer
Condenser motor (Rotary fan) suitable for any type and any capacity deep freezer Make; AUE/Cool Blow/Universal
Starting capacitor suitable for Deep freezer suitable for any type and any capacity deep freezer
Supply only following items suitable for DESERT COOLER:-
Fan motor of capacity 1/6 HP (125 W), 230 V, 50 Hz, SP, AC supply confirming to IS-996/79 (motor only) with mounting accessories Make- Khaitan/Cool Blow/CG/Bajaj
Water circulating submesible pump, 1300 RPM, SP, 230V, 50Hz 1.5M head , discharge 7.0 Ltrs/hr Make:Indo/Summer Cool
Filter pad made out of wooden wool suitalbe for Air grills of desert cooler as per existing size
PVC Flexible hose suitable for desert cooler cooling system
PVC Fan Blade suitable for 3000/4000/5000/6000 as per sample
Bolt, nut with washers as per sample
PVC Connector i.e (Elbow, Tee,4 way etc)
Switch 5 Amps
Indication lamp
Front Panel as per existing size and model
PVC swirtch box as per sample and size
GI Chicken Mesh
PVC Insulated copper conductor and PVC over all coverd cord cable copper conductor 3 core of size 2.5 Sqmm Make :Plaza/Havells/ Finolex
M&L for Sub main wiring with 2.5 Sqmm (nominal area), PVC insulated, multistranded, single core unsheathed, copper conductor cables passing through and including PVC casing caping with all fittings and accessories of PVC casing caping (like Tee, bend etc.) complete fixed to walls /ceiling etc. with and including 2x2.5Sqmm and 1x2.5 Sqmm Warth wire PVC insulated, unsheathed, stranded, single core, copper cable green in colour as earth continuity wire connecting to common earth point including PVC terminal box fixed with suitable sizes cadmium plated iron screws and washers etc.for mounting switches, sockets, regulators etc complete for one light point controlled by one ,one way switches including taking down as specified and directed. complete all as specified and as directed .(Note :- PVC conduits/casing caping and Two runs cables and one run of earth wire will be measured as one length.)
Carry out day to day rectification any make, any capacity of Air Curtains complaints at Area I & Area II like testing of Air Curtain any Capacity, replacement of defective capacitor, , Indication lamp, 5 Amps switch , Fan blade, Fan Motor, PVC Connector, alongwith bracket, wiring etc complete all as directed by the Engineer-in-Charge Note (i) . Replacement of Spares and fitting shall be measured and paid separately.(ii) If required shifting of Air curtain shall be measured and paid separtely. (iii). Petty stores such as insulation tape, screws, small pieces of wires,plug top etc shall be provided by the Contractor without any extra cost to the department (iv). Air curtain Mechanic along with Helper so detailed by the contractor will report to MES complaint cell at 08.45 Hrs morning to receive complaints(Complaint slip provided by the contractor) from department and complaint should be rectified with in a same day. (v). Rate included with transport vehicle provided by the contractor to attending the complaints Area I&II
M&L for mild steel frame work such as in cooler stand ,water tanks/ desert cooler stand and similar work con-forming to FE 290 Gde E-165 including mounting on wall with suitable size nut bolt and grouting and making good disturb surface including taking out old rusted mild steel desert cooler stand complete all as specified and directed.
SHRI RAM ELECTRICALS ENTERPRISES
M/S SHIVA TRADERS
shubhanshu traders
Bidder Name
dipangashu barick and associates
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .