Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹17.9 LAccepted-AOC | L1 | Accepted-AOC work awarded | |
| 2 | L2₹19.2 L+₹1.4 L (7.67%)Rejected-AOC | L2 | Rejected-AOC L2 | |
| 3 | L3₹19.9 L+₹2.0 L (11.2%)Rejected-AOC | L3 | Rejected-AOC L3 |
Tender Value
₹21.8 L
EMD Value
₹43,620
Closing Date
27 Dec 2019, 6:00 pmClosed
AGM (Engg-Civil)-I
Pune Airport
Repairs to Apron cracks/Potholes at Pune Airport, Pune.
2019_AAI_38023_1
AAI/PUNE/ENGG-C/APRON REPAIR/2019
Open Tender
Civil Works
Item Rate
365 days
Pune Airport
AS per NIT
6 documents required · 6 mandatory
₹1,180
Airport Authority of India
₹43,620
25 Jul 2022
12 Dec 2019
2 Jan 2020
13 Dec 2019
27 Dec 2019
13 Dec 2019
13 Dec 2019 - 26 Dec 2019
Amount
Repair of Cracks on Apron Area : Repairing of surface cacks by chipping out deteriorated concrete surface, cutting of "U" shaped groove of approx. 40 mm (W) X 30 mm (D) along the cracks & repairing with filling Xypex Megamix II & Xypex Xycrylic admixture or Vendex mortar & vendex chemelast liquid or equivalent material by mixing in proper ratio as reccomended & specified by the manufacturer, coating of primer/bonding coat by the same manufacturer and repairing the surface complete. The item include cost of all material, labour and T&P, all taxes etc complete in all respct as per satisfaction and direction of Engineer-in-charge. The vital values/parameters of the material shall be as under: a) Direct Tensile Bond Strength (2.3 Mpa - ACI 503R) b) Low shrinkage fiber reinforced c) Chemical durability (mass loss negligible i.e. 0.22% in 84 days - ASTM C 267) d) Comperssive strength (59.3 Mpa @ 28 days -ASTM C 109) e) Rapid chloride permeability (420 coulombs @ 90 days - ASTM C 1202) f) Flexural Strength (8.2 Mpa - ASTM C 78 @ 28 days) g) Splitting Tensile Strength ( 4.2 Mpa -ASTM C 496) h) Scaling Resistance (no scaling in 50 cycles - ASTM C 672) including cost of all material, labour and T&P, complete in all respect as per satisfacton and direction of Engineer-In-Charge. i) Setting Time as per ASTM C 266 : initial : 4:10 hrs:min & final : 7:10 hrs:min The repair & filling shall be got done through the authorised applicator of the manufacturer after approval of Engineer-in-charge.
Repairing of Pot Holes, Edges & Deep Patches of Apron: Repairing of Pot Holes, Edges & Deep Patches by chipping out deteriorated concrete surface, cutting it in square shaped groove & repairing with filling Xypex Megamix II & Xypex Xycrylic admixture or Vendex mortar & vendex chemelast liquid or equivalent material by mixing in proper ratio as reccomended & specified by the manufacturer, coating of a primer/bonding coat by the same manufacturer and repairing the surface complete. The item include cost of all material, labour and T&P, all taxes etc complete in all respect as per satisfaction and direction of Engineer- in - charge.The vital values/ parameters of the material shall be as under: a) Direct Tensile Bond Strength (2.3 Mpa- ACI 503R) b) Low shrinkage fiber reinforced c) Chemical durability (mass loss negligible i.e. 0.22% in 84 days - ASTM C 267) d) Compressive strength (59.3 Mpa@ 28 days - ASTM C 109) e) Rapid chloride permeability (420 coulombs @ 90 days - ASTM C1202 f) Flexural Strength (8.2 Mpa- ASTM C 78 @ 28 days) g) Splitting Tensile Strength (4.2 Mpa - ASTM C 496) h) Scaling Resistance (no scaling in 50 cycles - ASTM C 672 Including cost of all material, labour and T&P, complete in all respect as per satisfaction and direction of Engineer- in - charge. i) Setting Time as per ASTM C 266 : initial : 4.10 hrs:min & final : 7:10 hrs:min. The repair & filling shall be got done through the authorised applicator of the manufacturer after approval of Engineer-in-charge.
Resurfacing of Worn out Concrete surface at Apron Area: Cleaning the wear out and deteriorated concrete surface/damaged concrete surface with wire brush & washing with water. After neatly cleaning the surface area, repairing the surface by applying bond coat of XYPEX Megamix-I mixed with XYPEX XYCRYLIC ADMIX & filling it with XYPEX Megamix-I mixed with XYCRYLIC ADMIX or Vandex Uni-mortar-I & Vandex chemelast liquid or equivalent material by mixing in proper ratio as recommended & specified by the manufacturer, coating of a primer/bonding coat by the same manufacturer and repairing the surface complete. The product should have following minimum property: a) Direct Tensile bond strength to concrete (1.24 Mpa- ACI 503R), b) Low shrinkage fiber reinforced, c) Compressive strength (24.9 Mpa @ 28 days - ASTM C 109) Item includes cost of all material, labour, T&P & all taxes complete in all respect as per satisfaction and direction of Engineer- in - charge. The repair & filling shall be got done through the authorised applicator of the manufacturer after approval of Engineer-in-charge.
rohan construction
Ms Ambaji Corporation
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .