Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹84,650Admitted-Finance | ₹84,650 | L1 | Admitted-Finance |
| 2 | L2₹1.2 LAdmitted-Finance | ₹1.2 L | L2 | Admitted-Finance |
| 3 | L3₹1.3 LAdmitted-Finance | ₹1.3 L | L3 | Admitted-Finance |
| 4 | Rejected-Technical | - | - | Rejected-Technical Not Fullfil PQR |
Tender Value
₹1.5 L
EMD Value
₹2,000
Closing Date
3 Feb 2026, 3:00 pmClosed
SE ETC Banda
SE ETC Office, 220 KV S/S Tindwari Road, Banda
WORK FOR REPLACEMENT OF 145 KV HV BUSHING OF 40 MVA TRANSFORMER ALONG WITH CENTRIFUGING OF TRANSFORMER OIL AT 220 KV SUB-STATION, BANDA UNDER ETD BANDA.
2026_UPTCL_1110157_1
Very Short Term E-Tender T-64/ETC(B)/2025-26
Open Tender
Electrical Works
15 days
Banda
As per tender document.
2 documents required · 2 mandatory
₹590
As per NIT
₹2,000
10 Feb 2026
28 Jan 2026
4 Feb 2026
28 Jan 2026
3 Feb 2026
28 Jan 2026
Details of work
Carriage of 01No 145 KV Bushing from 132 KV Sub-Station Atarra, Banda to 220KV Sub-Station, Banda including loading, carriage and unloading by in a private track (Truck Crane shall be arranged by the contactor at his own cost.)
Removal of Jumpers of HV side Bushings of the 40 MVA T/F-III. The Scope of work involves removal of Jumpers, Bushing Clamps, Opening of Earthing of Neutral Bushings of the Transformer.
Partial drain out the Transformer oil from 40 MVA T/F as required in amply oil drums for replacement of defective HV bushing.
Dismantling of damaged Y Phase HV bushing of 40 MVA T/F-III Transformer by opening cutting of top thumble removal of bushing from tank and covered with blanking plate etc. (Crane shall be arrange by the contractor at his own cost)
Fixing of New HV bushing in place of defective HV bushing Replacement of gasket and fixing of lead thumble. (Crane shall be arrange by the contractor at his own cost)
http://sq.mm/(http://sq.mm/塹ᴻ䡿ⲯ嶂藄挧ꮥ)
Re-Jumpering of HV side Bushings of the above 40 MVA T/F-III. The scope of work involves Fixing & Tightening of Bushing Clamps & Jumpers along with earthing of the Neutal Bushings by Fixing of Flexible Copper Strips.
Performing following detailed testing of Oil Samples of above both transformers Transformer at CPRI, PGCIL or any other NABL Cetified Lab including collection of Sample in Air Tight Bottles of proper specification as per standard pratice and submission of Reports:- 1.BDV, 2.PPM (1 Job for one Oil Sample of which all above tests shall be done)
Rates qouted by the bidders shall be without taxes. Taxes applicable if any to paid extra
Please Enable Macros to View BoQ information
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.21 MB
TenderDocumentT64.pdf
Tender Documents • 0.87 MB
BOQ_2050147.xls
BOQ • 0.28 MB
Download all tender documents and submit your bid