Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹38.7 LAccepted-AOC GROUND BALURGHAT COMPOUND NEAR TRIPURA ROAD KHANAPARA ROAD GUWAHATI KAMRUP METROPOLITAN ASSAM 781029 | KAMRUP METRO | ASSAM | 781029 | L-1 | Accepted-AOC RATES ARE FOUND REASONABLE AND THE FIRM BEING L1 BIDDER | |
| 2 | L-2₹43.1 L+₹3.9 L (9.97%)Rejected-Finance F NO A1 APURBA ENCLAVE BRINDABAN PATH RUPNAGAR KAMRUP GUWAHATI ASSAM 781005 | KAMRUP METRO | ASSAM | 781005 | L-2 | Rejected-Finance BEING L2 BIDDER | |
| 3 | L-3₹43.2 L+₹4.0 L (10.3%)Rejected-Finance B 1 16 MILAN GARDEN SABHAPUR EXTENSION NEAR BHIKAM SINGH TUBE WELL NEW DELHI 110094 | NORTH EAST | DELHI | 110094 | L-3 | Rejected-Finance BEING L3 BIDDER | |
| 4 | L-4₹43.4 L+₹4.2 L (10.7%)Rejected-Finance E TEZ 355 2024 PO PS RANGIA DIST KAMRUP ASSAM 781365 | RANGIA | KAMRUP | ASSAM | 781365 | L-4 | Rejected-Finance BEING L4 BIDDER | |
| 5 | L-5₹45.9 L+₹6.8 L (17.3%)Rejected-Finance VILL KAHIKUCHI PS PO AZARA DIST KAMRUP GUWAHATI ASSAM 781 017 | KAMRUP METRO | ASSAM | 781017 | L-5 | Rejected-Finance BEING L5 BIDDER |
Tender Value
₹42.1 L
EMD Value
₹84,300
Closing Date
18 Jul 2024, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE Rangia
GE Rangia C/O 99 APO Rangia
SPL REP AGAINST CERTAIN BER ITEMS AT CERTAIN UNIT
2024_MES_664730_1
RNG/8792/E8
Open Tender
Civil Works
Item Rate
180 days
Hattigor
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
Yes
GE Rangia
₹84,300
Yes
4 Oct 2024
8 Jul 2024
20 Jul 2024
8 Jul 2024
18 Jul 2024
13 Jul 2024
8 Jul 2024 - 10 Jul 2024
Amount
Dismantling ACSR or AAC Conductors from the disturbed span including line spacer, etc., complete all as specified and as directed by Engineer-in-charge.
Dismantling stay assembly of any description and any size including MS clamps with nut-bolt-washers, demolition of Cement Concrete (as/if required) and made good disturbed Ground, complete all as specified and as directed by Engineer-in-charge. NOTE: Unserviceable stay assembly will be dismantled at Ground Level and disturbed ground will made good as directed for which Earthwork, demolition of Cement Concrete, etc. will not be measured and paid separately.
Dismantling Cross-Arms of Mild Steel Channel or Angle Sections, etc, including Mild Steel Bolts, Nuts, Washers, etc., complete all as specified and as directed by Engineer-in-charge.
Dismantling Insulators like Pin type, Shackle type from existing Street/ Security Light Pole of any description and any size, seggregating Seviceable Insulators and keep in safe custody for re-use, complete all as specified and as directed by Engineer-in-charge.
Taking down service connection cable of any description with all fittings, removing materials from site and making good distrubed surface of wall, floors, etc. complete all as specified and as directed by Engineer-in-charge. NOTE: Earthwork will be measured and paid separately.
M& L for Excavation in trenches n.exc 1.5m wide and n.exc 1.5 m in depth for foundation etc or for shafts, wells, cesspits, manholes, pier holes etc. and getting out in soft/loose soil complete all as per specified and as directed by Engineer-in-charge.
M&L for Returning, filling in, including spreading, leveling, watering and well ramming in layers n exc 25cm complete all as per specified and as directed by Engineer-in-charge.
M&L for Removing excavated material not exc. 50 m & depositing where directed at a level not exc. 1.5 m above starting point complete all as per specified and as directed by Engineer-in-charge.
M&L for Sand Cushioning (dry) in trenches/ducts for protection of UG Cables (below, above and around the UG Cable laid in Trenches) of 230mm Spread thickness (8 Cm in depth before laying the Cable and 15 Cm in depth after laying the Cable) and consolidated (punned) upto 180mm thickness, complete all as per specified and as directed by Engineer-in-charge. NOTE : For the purpose of Payment, Punned thickness of Sand Cushioning only will be measured and paid for.
Supply & Laying Sub-Class B Bricks, well burnt, laid breadth wise along the length of cable laid in trenches over sand cushion laid for UG cable protection, complete all as specified and as directed by Engineer-in-charge.
S&F of Galvanised Iron Pipe 40mm bore (dia) ‘light grade’ for protection of UG Cable, laid under Floors or Road Crossing, fixing to Pole with and including Mild Steel Clamps, Nuts, Bolts, etc., complete all as specified and as directed by Engineer-in-charge.
All as per Item No. 11 here-in-above, but for 50mm bore (dia) pipe, complete all as specified and as directed by Engineer-in-charge.
All as per Item No. 11 here-in-above, but for 80mm bore (dia) pipe, complete all as specified and as directed by Engineer-in-charge.
S&F of 25mm dia High density poly ethylene pipes (HDPE) of pressure rating 6 kg/ cm2 fixed to walls and ceilings or laid in floors/ trenches for protection of Cable, complete all as specified and as directed by Engineer-in-charge.
Supply & laying of LT XLPE insulated cable, sheathed, screened, PVC bedded, Galvanised Steel Strip or Wire armoured, Electic Power Cable (heavy duty) with Aluminium Conductor, 1100 Volts grade, cross-sectional area 150 Sqmm 3.5 Core, laid in Pipe/ Ducts/ Trenches/ under Floor/ under Road/ fixing on pole/ above floor including Testing, complete all as specified and as directed by Engineer-in-charge. NOTE : Earthworks, Sand Cushioning, Bricks, GI Pipe, etc. will be measured and paid under appropriate Items.
All as per Item No. 15 here-in-above, but for cross-sectional area 120 Sqmm 3.5 Core, laid in Pipe/ Ducts/ Trenches/ under Floor/ under Road/ fixing on pole/ above floor including Testing, complete all as specified and as directed by Engineer-in-charge.
All as per Item No. 15 here-in-above, but for cross-sectional area 95 Sqmm 3.5 Core, laid in Pipe/ Ducts/ Trenches/ under Floor/ under Road/ fixing on pole/ above floor including Testing, complete all as specified and as directed by Engineer-in-charge.
All as per Item No. 15 here-in-above, but for cross-sectional area 70 Sqmm 3.5 Core, laid in Pipe/ Ducts/ Trenches/ under Floor/ under Road/ fixing on pole/ above floor including Testing, complete all as specified and as directed by Engineer-in-charge.
All as per Item No. 15 here-in-above, but for cross-sectional area 35 Sqmm 3.5 Core, laid in Pipe/ Ducts/ Trenches/ under Floor/ under Road/ fixing on pole/ above floor including Testing, complete all as specified and as directed by Engineer-in-charge.
All as per Item No. 15 here-in-above, but for cross-sectional area 25 Sqmm 3.5 Core, laid in Pipe/ Ducts/ Trenches/ under Floor/ under Road/ fixing on pole/ above floor including Testing, complete all as specified and as directed by Engineer-in-charge.
All as per Item No. 15 here-in-above, but for cross-sectional area 16 Sqmm 4.0 Core, laid in Pipe/ Ducts/ Trenches/ under Floor/ under Road/ fixing on pole/ above floor including Testing, complete all as specified and as directed by Engineer-in-charge.
All as per Item No. 15 here-in-above, but for cross-sectional area 16 Sqmm 2.0 Core, laid in Pipe/ Ducts/ Trenches/ under Floor/ under Road/ fixing on pole/ above floor including Testing, complete all as specified and as directed by Engineer-in-charge.
All as per Item No. 15 here-in-above, but for cross-sectional area 10 Sqmm 2.0 Core, laid in Pipe/ Ducts/ Trenches/ under Floor/ under Road/ fixing on pole/ above floor including Testing, complete all as specified and as directed by Engineer-in-charge.
M&L for Multistranded Copper Conductor flexible cable of 3 Core 1.5 Sq mm size drawn through steel tubular poles for interconnection of cable looping box to street light Fitting, Post Top Lantern & etc including taking down old unserviceable cable complete all as specified and as directed by Engineer-in-charge.
S&F of Pole Box/Junction Box of size 205 X 255 X 112mm (LxBxH) made out of Polycarbonate material totally enclosed, dust and vermin proof, door pasted with rubber gasket, water tight IP 66/67 protection single leaf shutter in front having proper locking arrangements, including provision of suitable connector for single phase connections loop in and out 10 to 16 Sqmm 4.0 Core aluminium armoured cable branch out 1.5 Sqmm single core PVC insulated copper cable and MCB SP 06 amps- 01 No and mounted on security light pole with suitable clamps (GI Flat iron of 25x3mm), nuts, bolts, complete all as specified and directed by Engineer-in-charge.
Supply, installation, testing and commissioning of Factory made (CPRI Approved) floor mounted Outdoor cubical type LT Panel Board of size 1100 X 800 X 450 MM fabricated out of 3.15 mm thick CRCA Sheet and angle iron 50 X 50 X 6 mm frame totally enclosed dust and vermin proof both side hinge opening arrangement on front and back, centre openable double door with locking arrangements, cable entry and exit from bottom with cable glands and gaskets, earth strip connections, Digital VAF Meter- 01 Set (Make- L&T/ Schneider/ Legrand/ Siemens), including LED indicating lamps- 03 Nos (Make- L&T/ Schneider/ Legrand/ Siemens), internal wiring of suitable size to be used for incoming and outgoing connection of all switches/MCCB's & Bus-bar. The TPN aluminium bus bars of capacity 400 Amps shall be insulated with colour coded heat shrinkable sleeve and shall be mounted on DMC/epoxy insulator, connected with Aluminium lugs, including powder coat painting (RAL-7032) on the surfaces externally & internally including necessary preparation of surfaces and providing PCC (1 : 3 : 6) type C-2 as in foundation all as specified and as directed, comprising of the following :- (a) Internal wiring with single core copper conductor cable/ PVC Insulated Copper Strip of suitable size incoming to bus bar and bus bar to outgoing MCCB/MCB-1Job. (b) Fine wiring with single core copper conductor cable for instruments/indicating lamps-1 Job. (c) Bus bar chamber comprising 04 Nos aluminium strip bus bar mounted on DMC ( Dough Moulding Compound) insulator and PVC sheathed of capacity 400 Amps with colour coding for RYB & N - 01 Set INCOMING (d) MCCB 250 Amp, 4 Pole , 415 Volts rating with, overload, short circuit fault protection 3 phase with neutral link specially fixed incoming supply (Breaking capacity 35KA)Ics=100% of Icu, with Spreader terminal of both side-01 No. OUT GOING (e) MCCB 160 Amp, 4 Pole , 415 Volts rating with, overload, short circuit fault protection 3 phase with neutral link specially fixed incoming supply (Breaking capacity 35KA)Ics=100% of Icu, with Spreader terminal of both side-01 No. (f) MCCB 100 Amp, 4 Pole , 415 Volts rating with, overload, short circuit fault protection 3 phase with neutral link specially fixed incoming supply (Breaking capacity 25KA)Ics=100% of Icu, with Spreader terminal of both side-01 No. (g) MCB Triple Pole & Neutral (TPN) 32 Amp, 415 Volts rating specially fixed out going supply (Breaking capacity 10KA)-02 Nos. (h) MCB Single Pole & Neutral (SPN) 32 Amp, 240 Volts rating specially fixed out going supply (Breaking capacity 10KA)-06 Nos. (02 Nos spare) (Note-Fixing arrangement diagram and line diagram of the panel shall be got approved by accepting officer before panel fabrication).
Supply, installation, testing and commissioning of Factory made (CPRI Approved) floor mounted Outdoor cubical type LT Panel Board of size 1000 X 750 X 450 MM fabricated out of 3.15 mm thick CRCA Sheet and angle iron 50 X 50 X 6 mm frame totally enclosed dust and vermin proof both side hinge opening arrangement on front and back, centre openable double door with locking arrangements, cable entry and exit from bottom with cable glands and gaskets, earth strip connections, Digital VAF Meter- 01 Set (Make- L&T/ Schneider/ Legrand/ Siemens), including LED indicating lamps- 03 Nos (Make- L&T/ Schneider/ Legrand/ Siemens), internal wiring of suitable size to be used for incoming and outgoing connection of all switches/MCCB's & Bus-bar. The TPN aluminium bus bars of capacity 300 Amps shall be insulated with colour coded heat shrinkable sleeve and shall be mounted on DMC/epoxy insulator, connected with Aluminium lugs, including powder coat painting (RAL-7032) on the surfaces externally & internally including necessary preparation of surfaces and providing PCC (1 : 3 : 6) type C-2 as in foundation all as specified and as directed, comprising of the following :- (a) Internal wiring with single core copper conductor cable/ PVC Insulated Copper Strip of suitable size incoming to bus bar and bus bar to outgoing MCCB/MCB-1Job. (b) Fine wiring with single core copper conductor cable for instruments/indicating lamps-1 Job. (c) Bus bar chamber comprising 04 Nos aluminium strip bus bar mounted on DMC ( Dough Moulding Compound) insulator and PVC sheathed of capacity 300 Amps with colour coding for RYB & N - 01 Set INCOMING (d) MCCB 160 Amp, 4 Pole , 415 Volts rating with, overload, short circuit fault protection 3 phase with neutral link specially fixed incoming supply (Breaking capacity 35KA)Ics=100% of Icu, with Spreader terminal of both side-01 No. OUT GOING (e) MCCB 100 Amp, 4 Pole , 415 Volts rating with, overload, short circuit fault protection 3 phase with neutral link specially fixed out going supply (Breaking capacity 25KA)Ics=100% of Icu, with Spreader terminal of both side-01 No. (f) MCB Triple Pole & Neutral (TPN) 32 Amp, 415 Volts rating specially fixed out going supply (Breaking capacity 10KA)-03 Nos. (g) MCB Single Pole & Neutral (SPN) 40 Amp, 240 Volts rating specially fixed out going supply (Breaking capacity 10KA)-01 No. (h) MCB Single Pole & Neutral (SPN) 32 Amp, 240 Volts rating specially fixed out going supply (Breaking capacity 10KA)-08 Nos. (Note-Fixing arrangement diagram and line diagram of the panel shall be got approved by accepting officer before panel fabrication).
Supply, installation, testing and commissioning of Factory made (CPRI Approved) floor mounted Outdoor cubical type LT Panel Board of size 900 X 700 X 450 MM fabricated out of 3.15 mm thick CRCA Sheet and angle iron 50 X 50 X 6 mm frame totally enclosed dust and vermin proof both side hinge opening arrangement on front and back, centre openable double door with locking arrangements, cable entry and exit from bottom with cable glands and gaskets, earth strip connections, Digital VAF Meter- 01 Set (Make- L&T/ Schneider/ Legrand/ Siemens), including LED indicating lamps- 03 Nos (Make- L&T/ Schneider/ Legrand/ Siemens), internal wiring of suitable size to be used for incoming and outgoing connection of all switches/MCCB's & Bus-bar. The TPN aluminium bus bars of capacity 300 Amps shall be insulated with colour coded heat shrinkable sleeve and shall be mounted on DMC/epoxy insulator, connected with Aluminium lugs, including powder coat painting (RAL-7032) on the surfaces externally & internally including necessary preparation of surfaces and providing PCC (1 : 3 : 6) type C-2 as in foundation all as specified and as directed, comprising of the following :- (a) Internal wiring with single core copper conductor cable/ PVC Insulated Copper Strip of suitable size incoming to bus bar and bus bar to outgoing MCCB/MCB-1Job. (b) Fine wiring with single core copper conductor cable for instruments/indicating lamps-1 Job. (c) Bus bar chamber comprising 04 Nos aluminium strip bus bar mounted on DMC ( Dough Moulding Compound) insulator and PVC sheathed of capacity 300 Amps with colour coding for RYB & N - 01 Set INCOMING (d) MCCB 100 Amp, 4 Pole , 415 Volts rating with, overload, short circuit fault protection 3 phase with neutral link specially fixed incoming supply (Breaking capacity 25KA)Ics=100% of Icu, with Spreader terminal of both side-01 No. OUT GOING (e) MCCB 40 Amp, 4 Pole , 415 Volts rating with, overload, short circuit fault protection 3 phase with neutral link specially fixed incoming supply (Breaking capacity 25KA)Ics=100% of Icu, with Spreader terminal of both side-01 No. (f) MCB Triple Pole & Neutral (TPN) 32 Amp, 415 Volts rating specially fixed out going supply (Breaking capacity 10KA)-01 No. (g) MCB Single Pole & Neutral (SPN) 32 Amp, 240 Volts rating specially fixed out going supply (Breaking capacity 10KA)-07 Nos. (Note-Fixing arrangement diagram and line diagram of the panel shall be got approved by accepting officer before panel fabrication).
M&L for earthing complete with galvanised steel earth plate electrode of size 600 mm x 600 mm x 6 mm thick buried directly in ground (earth pit not less than 2.25 mtr deep below normal ground level) with top edge of the plate not less than 1.5 mtr below ground level, connected to galvanized earth lead of 32x6 mm by means of bolts nuts check nuts & washers of galvanized iron or steel , procteded by GI pipe 40 mm bore( light grade) and watering pipe 50 mm bore GI pipe (light grade) and chamber and coping shall be in PCC 1:3:6 type C1 using 20mm graded stone agg. 50 mm thick cover of RCC 1:2:4 type B1 using 20 mm graded stone agg. reinforced with 8 mm dia MS tor bar @ 80 mm c/c both ways including excvation and earth work and removal of surplus soil complete all as shown in electrical plate no 3 of SSR PT 1, 1991 with charcoal dust and salt complete and earth lead connected to earthing test point (up to main switches, DBs), complete all as specified & testing on completion. NOTE:- (i) item includes the cost of 7.5 mtr length GI pipe for protection for GI earth lead. (ii) item rates includes the cost of 7.5 mtr GI earth lead.
S&F of ceiling fans complete with blades, down rods and other accessories, 230 V, 1400 mm sweep, Min air delivery 210 CFM with service value 6.00, BEE Five star rated with brushless direct current motor (BLDC), including connecting up with three core flexible copper cables of suitable size, complete all as specified and as directed by Engineer-in-charge.
All as per Item No. 30 here-in-above, but for 1200mm sweep ceiling fan, complete all as specified and as directed by Engineer-in-charge.
S&F of PVC body wall mounted fans, 230 V, 50Hz, 400 mm sweep with brushless direct current motor (BLDC), complete all as specified and as directed by Engineer-in-charge.
S&F of exhaust fan, heavy duty, steel body, AC single Phase, 230V of size 300m sweep with, blades, frame and louvers including connecting up with three core flexible copper cables of suitable size, complete all as specified and as directed by Engineer-in-charge.
S&F of electric water heater (Geyser), vertical type storage, steel body and stainless steel inner tank with fero glass coating for corrosion resistance and heating element upto 2 KW capacity 25 litre, BEE 5 Star rated complete with all accessories such as safety valve, thermostate, NRV, connection piece etc, including commissioning and testing complete all as specified and as directed by Engineer-in-charge.
All as per Item No. 34 here-in-above, but for BEE 4 Star rated 50 litre geyser, complete all as specified and as directed by Engineer-in-charge.
S&F of metal top 300-320 litre capacity deep freezer, single phase, 230 volts, BEE 5 Star rated complete with all accessories, including commissioning and testing complete all as specified and as directed by Engineer-in-charge.
SWASTIKA TELESERVICES (BID ID -3065685)
M/S K D TURAIHA (BID ID -3063554)
M/S SHARMA ENGINEERING & COMPANY (BID ID -3064613)
R. D. ENTERPRISE (BID ID -3065301)
M/s B.M. Enterprise (BID ID -3065692)
JIBAN CHANDRA MEDHI (BID ID -3065533)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .