Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹14.9 LAccepted-AOC NO 9 1ST FLOOR C J N HERITAGE PWD MAIN ROAD AKASH NAGAR B NARAYANAPURA DOORAVANI NAGAR BANGALORE 560016 | BANGALORE | BENGALURU URBAN | KARNATAKA | 560016 | L1 | Accepted-AOC L1 | |
| 2 | L2₹16.1 L+₹1.2 L (8.07%)Rejected-AOC NO S 7 2ND CROSS 2ND MAIN KEB LAYOUT SANJAYANAGAR BANGALORE 560094 | BENGALURU URBAN | KARNATAKA | 560094 | L2 | Rejected-AOC L2 | |
| 3 | L3₹16.9 L+₹2.0 L (13.6%)Rejected-AOC NO 68 ANJANEYA TEMPLE CROSS OPP M S RAMAIAH HOSPITAL NEW BEL ROAD BANGALORE 560 094 | BENGALURU URBAN | KARNATAKA | 560094 | L3 | Rejected-AOC L3 | |
| 4 | L4₹17.1 L+₹2.2 L (14.8%)Rejected-AOC | L4 | Rejected-AOC L4 |
Tender Value
₹14.5 L
EMD Value
₹29,000
Closing Date
7 Jul 2020, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Shri Vineet Modi
CWE AF North Bangalore Bellary Road JC Nagar Post Bangalore 560006
PROVISION OF WALK IN COOLER FOR PATHOLOGY DEPARTMENT AT CHAF BANGALORE
2020_MES_352069_1
87492CWEAFNBAN
Open Tender
Miscellaneous Works
Item Rate
180 days
GE AF BANGALORE
AS PER NIT
5 documents required · 5 mandatory
₹500
GE AF BANGALORE
₹29,000
Yes
11 Aug 2020
11 Jun 2020
9 Jul 2020
11 Jun 2020
7 Jul 2020
25 Jun 2020
12 Jun 2020 - 22 Jun 2020
60 days
Amount
Excavation in trenches not exc. 1.5 m wide and not exc. 1.5 m deep and getting out in hard/dense soil all as directed and specified.
Returning filling in including spreading leveling watering and well ramming in layers not exc 25 cm thick all as specified.
Removing of surplus excavated material to a distance not exceeding 50 m and depositing where directed at a level not exc 1.5 m above the starting point all as specified .
M&L for ordinary sand cushioning 8cm thick below the cable & 15cm above the cable and punned down to 10cm from top of cable complete all as specified. Total spread thickness shall be 23 cm and measured 18 cm compacted thickness for payment).
Material and labour for old size bricks sub class 'B' laid in trenches for cable protection laid flat adjacent to each other and length perpendicular to direction of cable all as specified and directed.
Supply, laying, testing and connecting XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, heavy duty, electric power cable LT 1100V grade with stranded aluminium conductor cable laid in trenches/ fixed on walls etc of size 3.5 core x 25 sqmm alongwith connecting accessories like lugs & gland etc complete all as specified and directed. Make:- Cable corporation of India/Asian Cable Co, Chattisgarh/Finolex cable Ltd, Pune/ Polycab/Gloster/Universal.
Supply and fix sheet metal enclosure with industrial socket plug top and MCBs TPN with pin 3P+E+N 415v 63 Amps all as specified and directed. Make : Larsen & Tubro, Legrand,ABB, Siemens, Schneider, Havells, Standard, HPL Electric & Power Ltd (HPL), *C&S Electric Ltd (C&S Electric), Indo-Asian.
Material and labour for earthing complete with galvanised steel earth plate electrode 600mm x 600mm x6mm thick burried directly in ground vertically to a depth not less than 2.25m deep below ground level with top edge earth plate at a depth not less than 1.5m below normal ground level connected to galvanised steel earth lead strip 25x4mm dia by means of bolts, nuts, check nuts and washewrs of galvanised steel and connected to mainswitch board or main control board as directed and including provision of concrete pit in PCC (1:3:6) type C1, pre- cast RCC (1:2:4) type B1 cover slab 54 cmx54cmx 5cm with one handle for lifting made out of 8mm dia MS bar, provision of funnel, wire mesh, 20mm bore galvanised steel tubing (med grade) for watering charcoal or coke and salt in alternate layers, 15mm bore galvanised steel tubing light grade for protection of earth lead connection, necessary excavation and earth work in any type of soil and including necessary testing complete all as shown on electrical plate No 3 of SSR part-I.
Supply and fix Servo Voltage stabilizer for automatic operation, three phase, naturally oil cooled, indoor type & designed for input variation between 300 V to 480 V with output voltage stabilized at 415 with accuracy ± 2.5% and speed of correction 8 Volts per second and of capacity 10 KVA including first filling of transformer oil all as specified and directed .Make:-Automatic electric/ Vinitec/V guard/Aplab/volina.
Design, supply, install, testing and commissioning prefabricated walk in cooler having 5 Ton refrigerating system and following features:- Roomsize 6.8x2.75x2.6m (a) Ambient temp 43 C (b )Designed room temp(+-2 Deg C)-0 deg C. (c)Product incomig temp@28deg C and Outgoing @ 0 deg C (d) PUF material insulation wall/ceiling 80mm thick PCGI panel lamination with 0.5mm sheet -70 Sqm (e) Pull down (Hrs) 24 hrs (f) door openings -5 times in a day (g) Floor thickness -80mm thick PPGI/plywood+Aluminium cheq sheet-20 Sqm (h) Type,size of Door in mm -80mm PUF insulated swing door of size(900x2000)mm with door PCGI finish-flush type lamination 0.5mm &Vaccumising glass for CR300x450 for door -01 Nos (i) High/Low audio alarm with hooter and switch -01 Nos (j) Vapour proof lights-02 Nos (k) split type refrigeration system (l)DX cooling type (m) 5 Ton x 2 Nos ( 1 working+ 1 stand by) refrigeration system with change over of standby system (n)R404a refrigerant as per required (o)Hermatic compressor and air cooled condensor unit-02 No (p) Evapourator unit 5 Ton system -02 No (q)inbuilt condensing unit electrical panel -01 No (r)MOC for evaporated units GI casing with axial fans -01 No (s)Micro processor based temp indicator cum controller -01 No (t) Pressure relief valve -01 No (u) Inter connecting piping and wiring between the cond units and evap units 6 RMT-01 No (v) suspention Tee-18 mtr (w) Suspension for freezer-06 Nos (x)PLC ,HMI with touch screen and Nano DAC data Logger system-01 Set (y) Racks made out of perforated stainless stell sheet and stainless steel structure of heavy duty for keeping the medicine-20 Nos (Each rack should contain min 4 shelves) (z) PCC (1:3:6) type C1 using 20mm graded stone aggregate base of size 7.1x3.0x0.15 mtr (aa) Emergency release button inside cabin - 01 No (ab) Drain out PVC pipe with necessary fixing. Make : Blue star or equivalent in Voltas/carrier/Daikin/Hitachi. Note : 1. The contractor shall obtain Design, specifications and layout/schematic diagrams from original manufacturers and the same submit to Deptt for approval of Accepting Officer before commencement of work. 2. The contractor is responsible in all respects for pre commissioning test and other tests as applicable by the accepting officer rep in the presence of manufacturer Engineers wrt BOQ Specifications/features etc on the site.
UNIVERSAL ENGINEERING
devan enterprises
mahadevi Enterprises
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .