Loading…
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹48.7 LAccepted-AOC C O APERNA TRADERS COURT ROAD UDHAMPUR 182101 J K | UDHAMPUR | UDHAMPUR | JAMMU AND KASHMIR | 182101 | L1 | Accepted-AOC Being lowest | |
| 2 | L2₹53.5 L+₹4.8 L (9.78%)Rejected-Finance HOUSE NO 102 LANE NO 4 C ANAND NAGAR BOHRI JAMMU 180002 J K | JAMMU | JAMMU AND KASHMIR | 180002 | L2 | Rejected-Finance Other than L1 | |
| 3 | L3₹63.8 L+₹15.1 L (30.9%)Rejected-Finance RSD STREET HALL BAZAR AMRITSAR 143001 PUNJAB | AMRITSAR | AMRITSAR | PUNJAB | 143001 | L3 | Rejected-Finance Other than L1 | |
| 4 | Rejected-Technical 361 BEHIND DAV SCHOOL JAWAHAR NAGAR SRINAGAR 190008 | SRINAGAR | JAMMU AND KASHMIR | 190008 | - | Rejected-Technical Not recommended since the firm has not been enlisted in category b (ii) | |
| 5 | Rejected-Technical SKALZANGLING AIR PORT ROAD LEH LADAKH 194101 | LEH | LEH | LADAKH | 194101 | - | Rejected-Technical Not recommended since the firm has not been enlisted in category b (ii) |
| Sl No | Description | Qty | Unit | KAMLA CONSTRUCTION COMPANY L1 | SUMEET TRADING CORPORATION L2 | Intrernational Engineers L3 |
|---|---|---|---|---|---|---|
| 1.00 | Supply, installation testing and commissioning of Outdoor type transformer with standard fittings and accessories, step down copper wound 11 KV on HT side and 433 volts on LT side at no load 3 phase 4 wire system 50 C/S AC supply of 250 KVA oil immersed laminated iron core naturally cooled with external tubes, delta connected on HT side and star connected on LT side corresponding to vector group DY-11 with neutral brought out separately for earthing including off load changing tap arrangement up to +7.5% in steps of + 2.5% each complete with first filling of transformer oil up to appropriate level and LT side suitable for connection complete all as specified and directed and conforming to IS 2026 (Part-I to Part-II) latest amended and IS 1180 Part I: 2014 BEE star level-I as per Govt of India, Ministry of Power notification Dated 16 Dec 2016 complete all as specified and/or as directed by Engr-in-Charge. | 1 | Each Job | 7,25,000 ₹7,25,000 Lowest | 11,70,000 ₹11,70,000 | 10,80,000 ₹10,80,000 |
| 2.00 | Supply, installation testing and commissioning of Outdoor type transformer with standard fittings and accessories, step down copper wound 11 KV on HT side and 433 volts on LT side at no load 3 phase 4 wire system 50 C/S AC supply of 160 KVA oil immersed laminated iron core naturally cooled with external tubes, delta connected on HT side and star connected on LT side corresponding to vector group DY-11 with neutral brought out separately for earthing including off load changing tap arrangement up to +7.5% in steps of + 2.5% each complete with first filling of transformer oil up to appropriate level and LT side suitable for connection with trunk bus bar and all connections shall be done through appropriate size of aluminium cable lugs and conforming to IS 2026 (Part-I to Part-II) latest amended and IS 1180 Part I: 2014 BEE star level-I as per Govt of India, Ministry of Power notification Dated 16 Dec 2016 complete all as specified and/or as directed by Engr-in-Charge. | 1 | Each Job | 6,10,000 ₹6,10,000 Lowest | 9,00,000 ₹9,00,000 | 9,55,000 ₹9,55,000 |
| 3.00 | Supply & fix Steel tubular swaged poles complete with cast iron/mild steel base plate, finial taper plug, bolts, nuts & screws as specified type 410 SP-55 (11 metre long) including drilling of necessary holes, & painting complete all as specified and/or as directed by Engr-in-Charge.
Note :- (i) Cost of painting & numbering on poles i.e. making five no. alternative white & black strips 30 cm height each (up to 1.50 metre height from top of PCC coping) & numbering to the poles with synthetic enamel paint etc shall be deemed to be included in the rates of above items.
(ii) Earthwork, PCC foundation & coping shall be measured and paid separately under respective item of Schedule A | 2 | Each | 22,000 ₹44,000 Lowest | 33,000 ₹66,000 | 26,900 ₹53,800 |
| 4.00 | Supply & fix Steel tubular swaged poles complete with cast iron/mild steel base plate, finial taper plug, bolts, nuts & screws as specified type 410 SP-31 (09 metre long) including drilling of necessary holes, & painting complete all as specified and/or as directed by Engr-in-Charge.
Note :- (i) Cost of painting & numbering on poles i.e. making five no. alternative white & black strips 30 cm height each (up to 1.50 metre height from top of PCC coping & numbering to the poles with synthetic enamel paint etc shall be deemed to be included in the rates of above items.
(ii) Earthwork, PCC foundation & coping shall be measured and paid separately under respective item of Schedule A | 18 | Each | 18,200 ₹3,27,600 | 22,000 ₹3,96,000 | 17,900 ₹3,22,200 Lowest |
| 5.00 | Supply, install, connecting and commissioning switch air break gang operated triple pole for current rating 200 Amp at 11 KV, out door type, mechanically operated, mounted on insulators with 9 insulator and steel frame, with operating mechanism and operating rod of 25mm bore GI pipe medium worked from ground level, with locking arrangements, complete all as specified and/or as directed by Engr-in-Charge. | 2 | Each set | 14,500 ₹29,000 | 14,000 ₹28,000 Lowest | 16,900 ₹33,800 |
| 6.00 | Supply and fix in replacement lightning arrestor suitable for 11 KV grade, thyrester type, complete with all fitting transmission class for outdoor discharge capacity 65 KA complete all as specified and/or as directed by Engr-in-Charge. | 2 | Set of three | 5,500 ₹11,000 | 3,500 ₹7,000 | 2,800 ₹5,600 Lowest |
| 7.00 | M&L for Anti-climbing device, spikes type fabricated out of M.S. bars (round, square and flat) including nuts, bolts, washers and welding in two halves made to shape to suit the cross section of the pole complete all as specified and/or as directed by Engr-in-Charge. | 2 | Each | 350 ₹700 Lowest | 500 ₹1,000 | 500 ₹1,000 |
| 8.00 | Material and labour for danger notice plate for HT of size 25 cm x 20 cm x 1.5 mm thick mild steel sheet, synthetic enamelled white with letters, figures and conventional skull and bones in signal red colour and fixed with MS clamps, bolts and nuts complete all as specified and/or as directed by Engr-in-Charge. | 8 | Each | 350 ₹2,800 | 200 ₹1,600 Lowest | 500 ₹4,000 |
| 9.00 | Material & labour for construction of platform for installation of transformer of size all as shown in Drawing No CELZ-TD-02-2022-PLATFORM FOR TRANSFORMER UPTO 300 KVA, complete all as specified & directed. | 2 | Each Job | 35,000 ₹70,000 Lowest | 65,000 ₹1,30,000 | 59,000 ₹1,18,000 |
| 10.00 | Material & labour for chain link fencing around PCC platform for 250 KVA/ 160 KVA transformer of size 6m x 6m x 1.8m including 50 x 50 x 6mm angle iron post embedded in PCC 1:3:6 type C2 foundation of size 0.3 x 0.3 x 0.45m including angle iron 50 x 50 x 6mm at corner braced with angle iron 25 x 6mm support including filling aggregate of 40mm to 63mm size of spread thickness 100mm all around. The platform along with entrance gate of size 1.5m wide and height same as fencing complete all as specified & directed. | 2 | Each Job | 25,000 ₹50,000 | 10,000 ₹20,000 Lowest | 40,000 ₹80,000 |
Tender Value
₹50.0 L
EMD Value
₹1.0 L
Closing Date
7 Aug 2025, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
CWE, HQ 138 WE
CWE, HQ 138 WE
PROVN OF 01 X 250 KVA AND 01 X 160 KVA TRANSFORMER ALONG WITH LT PANEL, CABLES AND CONNECTED ACCESSORIES AT ASC AND COSR UNDER GE 865 EWS
2025_MES_718241_1
138WE/L-126/2025-26
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE 865 EWS
AS PER TENDER DOCUMENTS
6 documents required · 6 mandatory
₹1,000
GE 865 EWS
₹1.0 L
Yes
23 Sept 2025
3 Jul 2025
14 Aug 2025
3 Jul 2025
7 Aug 2025
24 Jul 2025
Amount
Supply, installation testing and commissioning of Outdoor type transformer with standard fittings and accessories, step down copper wound 11 KV on HT side and 433 volts on LT side at no load 3 phase 4 wire system 50 C/S AC supply of 250 KVA oil immersed laminated iron core naturally cooled with external tubes, delta connected on HT side and star connected on LT side corresponding to vector group DY-11 with neutral brought out separately for earthing including off load changing tap arrangement up to +7.5% in steps of + 2.5% each complete with first filling of transformer oil up to appropriate level and LT side suitable for connection complete all as specified and directed and conforming to IS 2026 (Part-I to Part-II) latest amended and IS 1180 Part I: 2014 BEE star level-I as per Govt of India, Ministry of Power notification Dated 16 Dec 2016 complete all as specified and/or as directed by Engr-in-Charge.
Supply, installation testing and commissioning of Outdoor type transformer with standard fittings and accessories, step down copper wound 11 KV on HT side and 433 volts on LT side at no load 3 phase 4 wire system 50 C/S AC supply of 160 KVA oil immersed laminated iron core naturally cooled with external tubes, delta connected on HT side and star connected on LT side corresponding to vector group DY-11 with neutral brought out separately for earthing including off load changing tap arrangement up to +7.5% in steps of + 2.5% each complete with first filling of transformer oil up to appropriate level and LT side suitable for connection with trunk bus bar and all connections shall be done through appropriate size of aluminium cable lugs and conforming to IS 2026 (Part-I to Part-II) latest amended and IS 1180 Part I: 2014 BEE star level-I as per Govt of India, Ministry of Power notification Dated 16 Dec 2016 complete all as specified and/or as directed by Engr-in-Charge.
Supply & fix Steel tubular swaged poles complete with cast iron/mild steel base plate, finial taper plug, bolts, nuts & screws as specified type 410 SP-55 (11 metre long) including drilling of necessary holes, & painting complete all as specified and/or as directed by Engr-in-Charge. Note :- (i) Cost of painting & numbering on poles i.e. making five no. alternative white & black strips 30 cm height each (up to 1.50 metre height from top of PCC coping) & numbering to the poles with synthetic enamel paint etc shall be deemed to be included in the rates of above items. (ii) Earthwork, PCC foundation & coping shall be measured and paid separately under respective item of Schedule A
Supply & fix Steel tubular swaged poles complete with cast iron/mild steel base plate, finial taper plug, bolts, nuts & screws as specified type 410 SP-31 (09 metre long) including drilling of necessary holes, & painting complete all as specified and/or as directed by Engr-in-Charge. Note :- (i) Cost of painting & numbering on poles i.e. making five no. alternative white & black strips 30 cm height each (up to 1.50 metre height from top of PCC coping & numbering to the poles with synthetic enamel paint etc shall be deemed to be included in the rates of above items. (ii) Earthwork, PCC foundation & coping shall be measured and paid separately under respective item of Schedule A
Supply, install, connecting and commissioning switch air break gang operated triple pole for current rating 200 Amp at 11 KV, out door type, mechanically operated, mounted on insulators with 9 insulator and steel frame, with operating mechanism and operating rod of 25mm bore GI pipe medium worked from ground level, with locking arrangements, complete all as specified and/or as directed by Engr-in-Charge.
Supply and fix in replacement lightning arrestor suitable for 11 KV grade, thyrester type, complete with all fitting transmission class for outdoor discharge capacity 65 KA complete all as specified and/or as directed by Engr-in-Charge.
M&L for Anti-climbing device, spikes type fabricated out of M.S. bars (round, square and flat) including nuts, bolts, washers and welding in two halves made to shape to suit the cross section of the pole complete all as specified and/or as directed by Engr-in-Charge.
Material and labour for danger notice plate for HT of size 25 cm x 20 cm x 1.5 mm thick mild steel sheet, synthetic enamelled white with letters, figures and conventional skull and bones in signal red colour and fixed with MS clamps, bolts and nuts complete all as specified and/or as directed by Engr-in-Charge.
Material & labour for construction of platform for installation of transformer of size all as shown in Drawing No CELZ-TD-02-2022-PLATFORM FOR TRANSFORMER UPTO 300 KVA, complete all as specified & directed.
Material & labour for chain link fencing around PCC platform for 250 KVA/ 160 KVA transformer of size 6m x 6m x 1.8m including 50 x 50 x 6mm angle iron post embedded in PCC 1:3:6 type C2 foundation of size 0.3 x 0.3 x 0.45m including angle iron 50 x 50 x 6mm at corner braced with angle iron 25 x 6mm support including filling aggregate of 40mm to 63mm size of spread thickness 100mm all around. The platform along with entrance gate of size 1.5m wide and height same as fencing complete all as specified & directed.
Supply, laying and testing cable XLPE insulated, armoured heavy duty electric cable with aluminium conductor,11000 volts grade, cross-sectional area of 95 sq mm 3 core complete all as specified and/or as directed by Engr-in-Charge.
Supply and fix cable jointing kit for 11 KV (Earthed) grade cable for outdoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 95 sqmm complete all as specified and/or as directed by Engr-in-Charge.
Supply, laying and testing cable XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area of 240 sq mm 3.5 core complete all as specified and/or as directed by Engr-in-Charge.
All as per serial item No. 13 above, but cables of size 150 Sqmm 3.5 core.
All as per serial item No. 13 above, but cables of size 95 Sqmm 3.5 core.
All as per serial item No. 13 above, but cables of size 70 Sqmm 3.5 core.
All as per serial item No. 13 above, but cables of size 50 Sqmm 3.5 core.
All as per serial item No. 13 above, but cables of size 35 Sqmm 3.5 core.
All as per serial item No. 13 above, but cables of size 16 Sqmm 4 core.
All as per serial item No. 13 above, but cables of size 16 Sqmm 2 core.
M&L for excavation in trenches, not exc. 1.5m wide and not exc. 1.5m in depth; for foundation, etc. or for laying UG cable in trenches, not exc 10sqm on plan and not exc 1.5 m in depth in hard/dense soil and getting out complete all as specified and/or as directed by Engr-in-Charge.
All as per Ser item No.21 above, but exceeding 1.5mtr depth and not exceeding 3mtr depth.
Returning, filling in (soil), including spreading, levelling, watering and well ramming in layers not exc. 25cm, complete all as specified and/or as directed by Engr-in-Charge.
Removing excavated material to a distance not exc. 50m and depositing where directed at a level not exc. 1.5m above the starting point, complete all as specified and/or as directed by Engr-in-Charge.
M&L for Sand cushioning to under ground cables 8 cm below the cable before laying & 15 cm above the cable after laying, complete all as specified in clause 19.75 of SSR Part-I, 2009. Note : Punned thickness only will be measured and paid.
Supply and laying of factory made, machine pressed, unreinforced, precast concrete cable cover class LV type-1 flat size 250 mm x 150 mm x 40mm, complete all as specified and directed
M&L PCC 1:4:8, type D2, using 40 mm graded stone aggregate as in foundation, filling, or mass concrete complete all as specified and/or as directed by Engr-in-Charge.
M&L for providing cement concrete in coping 1:3:6, type B-1 using 20 mm graded crushed stone aggregate including necessary form work complete all a specified and directed by Engr-in-Charge.
M& L of GI Pipe 80 mm dia light grade for cable protection in road crossing and making good surface road by filling with PCC 1:2:4 type B-0 using 12.5 mm graded crushed stone aggregate to match the existing surface complete all as specified and directed .
All as per Ser item No. 29 above, but 40 mm dia bore.
Supply and fix junction box made of mild steel 1.6 mm thick of size 250mmx200mmx105mm incl 4 Nos aluminium bus bar of 2 mm thick duly fitted on the suitable insulator with fixing with 35x6mm ms flat iron with nut, bolt and washer and incl one MCB SP 6 amp with rail fitted in MS box incl suitable size cable hole, gland duly painted with one coat of aluminium paint over a coat of red oxide etc complete all as specified and directed by Engr-in-Charge. Make M/s Sintex Industries Ltd. Cap Part No. GSMB - 2520 or equivalent approved make as approved by GE.
Supply and fix LED street light fitting 60 Watt 230 V AC outdoor type with high pressure die cast aluminium hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete all as specified and directed by Engr-In-Charge.
Supply and fix street light bracket fabricated out of GI Tubing light grade 40/50 mm bore bend to the shape as directed and not less than length 1.20 Mtr long complete with Mounting MS Clamp of Flat Iron size 25x4 mm of suitable length of 02 Nos incl nut bolts etc. of suitable size complete all as specified and directed by Engineer-In-Charge.
Supply and installation overhead, aluminium conductor, steel reinforced, including making connections and fixing on poles with all necessary arrangements, complete all as specified and as directed by Engineer-In-Charge. Note: Weight of ACSR or all aluminium conductors drawn for overhead lines is to be determined by measuring horizontal distance between centres of two adjacent poles and compounding the weight of conductors of that size and length and 3% extra added for sag, jointing, jumpers, etc.
M&L for Cross arms, bracings, supports, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed inclusive of one primer coat, one under coat and one finishing coat of paint, complete all as specified and as directed by Engineer-In-Charge.
M&L for Pin type, porcelain, vitreous, white, green & brown insulator including one galvanised iron steel spindle, two galvanized iron washer and one galvanised iron nut, working pressure 1100 Volts and of size 65 mm dia and 100 mm height ISI marked complete all as specified and directed by Engr in charge.
M&L for shackle type, porcelain, vitreous, white, green & brown insulator including one galvanised iron steel spindle, two galvanized iron washer and one galvanised iron nut, working pressure 1100 Volts and of size 115 mm dia and 100 mm height ISI marked complete all as specified and directed by Engr in charge.
M&L for stay assy using stay rod 20 mm dia complete with accessories as shown in electrical plate No 1 of SSR-1991 part-I incl. galvanized steel wire stranded of size 7/4mm complete all as specified and directed by Engr in Charge.
M & L for installing, testing and commissioning of factory made bus bar chamber comprising of 4 Nos aluminium bus bar of 200 Amp rating supported on insulator and enclosed with sheet steel enclosure out door type made out of 3.15 mm thick CRCA sheet, with top edge tappered, dust and vermin proof, having locking arrangement at front and opening arrangement from front & rear both including fixing arrangement on pole/gorunting in floor, with colour coded FRP with compression cable glands for entry & exit of cables, powder coated all specified and directed by Engr-in-Charge.
Supply and fix of twin core flat or round sheathed stranded copper conductor cable 1.5 Sqmm all as specified and directed by Engr-in-Charge.
M&L horizontal boring in soft/loose soil/under roads of any width by manual arrangements for inserting GI pipe up to 100mm bore for passing cables complete all as specified and/or as directed by Engr-in-Charge.
Supply and fix street Light Timer switch single phase 8 Kw, 230 Volt as a pole mountable SMC enclosure consisting of Nature Switch-02 as the controlling unit, Power Contactor & MCBs 32 Amps (both Input- Output) of suitable power rating and Copper wiring (min. 10 sq mm) with proper lugs and terminal blocks. The SMC enclosure comes complete with open able door and mounting clamps. The SINTEX make enclosure is made of UV stabilized, FR grade special moulding compound and it is Rust Proof, Electric Shock Proof Termite proof, Outdoor mountable confirming to IP-54 complete all as specified and as directed by Engineer-in-Charge. Make - Swadeep-02EC 8 kW3P-VMS or equivalent in Healer/L&T/HPL.
Earthing complete with galvanised iron earth plate electrode 600x600x6mm buried directly in ground (earth pit not less than 2.25mtr deep below ground level) with top edge of earth plate not less than 1.5mtr below normal ground level, connected with 32x6 mm size GI strip as earth lead, by means of bolts, nuts, check nuts and washers of galvanized iron or steel complete with 40mm dia GI light grade protection pipe, 20mm dia GI medium grade watering pipe with funnel including charcoal, dust, salt, PCC M-15, type B-1 in pit with precast RCC M-15(1:2:4), type B-1 (using 20mm graded crushed stone aggregates) in cover reinforced with XPM not less than 4.0 Kg per Sqm, test point etc. all as shown in electric plate No-3 of SSR Part-I (2009), complete with necessary earth work in any type of soil, removal to a distance not exceeding 50mtr, including testing on completion, complete all as specified and as directed by Engineer-In-Charge. Note : Earth pit chamber and RCC pit cover shall be painted with two coats of red synthetic enamel paint over one coat of primer including preparing of surfaces.
SUMEET TRADING CORPORATION (BID ID -3378736)
Intrernational Engineers (BID ID -3382203)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .