Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹9.9 CrAccepted-AOC NO 143 1 ARTHI NAGAR 2ND STREET NARASOTHIPETTAI KURANGUSAVADI SELAM 636 304 | SALEM | TAMIL NADU | 636304 | ₹9.9 Cr | L1 | Accepted-AOC L1 |
| 2 | L2₹9.9 CrRejected-AOC 121 THIRUMURUGAN NAGAR VEERIYAMPALAYAM ROAD KALAPATTY POST COIMBATORE 641048 | COIMBATORE | TAMIL NADU | 641048 | ₹9.9 Cr | L2 | Rejected-AOC L2 |
| 3 | Rejected-Technical R MUTHUSAMY BROTHERS INDUSTRIAL COMPLEX T S NO 6 2 PALLADAM ROAD TIRUPPUR 641 604 | TIRUPPUR | TIRUPPUR | TAMIL NADU | 641604 | - | - | Rejected-Technical Not responsive |
| 4 | Rejected-Technical 9 A PONGALIVALASU KODUMUDI POST ERODE 638 151 | KARUR | TAMIL NADU | 638151 | - | - | Rejected-Technical Not responsive |
| Sl No | Description | Qty | Unit | RSK CONSTRUCTION AND PROJECTS L2 | SRI VARI CONSTRUCTIONS L1 |
|---|---|---|---|---|---|
| 1.00Admin Building | |||||
| 1.01Part A - External Street Light | |||||
| 1.02 | Design, manufacture, supply, erection, testing and commissioning of 415 V streetlight service feeder pillar panel 1200mm x 900mm x 300mm suitable for outdoor installation, made up of CRCA sheet steel of thickness not less than 2 mm with a weather proof canopy of top, double door construction, IP 55 protection, with 2 coat of primer and 2 coats of aluminium finish with 1no. 125 A TPN MCCB with 16 kA breaking capacity in the incoming and 8 nos 32 A, TPN contactor 10 nos. 40A TPN MCB, 12nos, 10A SP MCB as outgoing, automatic dawn and dusk with cyclic timer control for street light outgoing and adequate plate to terminate suitable cable as incomer and suitable cable as outgoing. energy saver for automatic switching ON/OFF as per pre-sets time cycle, digital multifunctional meter with RS485 port and suitable CT etc. including the pillar to be erected with suitable angle iron frame pedestal with concrete grouting etc., complete and as directed by SIPCOT officers. | 1 | No | 1,00,000 ₹1 L | 1,00,000 ₹1 L |
| 1.03 | Supplying and erection of 8m Free Standing Double Arm Bracket 8 sided Octagonally continuously tapered structured pole galvanized iron coated (GI) with minimum coating of not less than 65-75 micron, with 130mm bottom A/F & 70mm at top A/F made up of 3mm thick HT sheet along with base plate of size 250x250x12mm thick including 4 Nos of M24X750mm high "J" type EN8 grade foundation bolts along with template and 1.5mtr long hot dip galvanized Single / double arm bracket made up of 40NB dia GI pipe suitable to mount on pole having top of 70mm A/F and including Bakelite sheet with 1 No 6A SP MCB and stud type connector suitable for 4CX25Sqmm cable etc., complete complying with standard specifications and as directed by SIPCOT officers. | 20 | Nos | 19,000 ₹3.8 L | 19,200 ₹3.8 L |
| 1.04 | Design, manufacture, testing and inspection at places of manufacturer, and supplying, delivery at site, unloading, storing, transporting directly to site or through transit stores as the case may be, installation, final painting, testing and commissioning of street lighting fixtures suitable for 80 W LED street light fitting with cool day light, made out of pressure die cast aluminium body, separate compartment for LED, including electronic drivers, day light colour LED lamps, inter connecting wiring with suitable fixing clams as required including accessories all inclusive etc., complete complying with standard specifications and as directed by SIPCOT officers. | 20 | Nos | 12,000 ₹2.4 L | 12,300 ₹2.5 L |
| 2.00Supply and laying of the following size of PVC armoured LTUG cable in a trench to be excavated at a depth of 0.75 metre putting 0.15 metre layer of sand and covering the three sides of the cable and refilling the earth to make good etc., complete and as directed by SIPCOT SIPCOT Officers. | |||||
| 2.01 | 4core x 16 sq.mm. Ar. Alu. UG cable ( For street light pole ) | 800 | Rm | 500 ₹4 L | 500 ₹4 L |
| 2.02 | 3.5core x 70 sq.mm. Ar. Alu. UG cable ( I/C to Feeder pillar box ) | 30 | Rm | 800 ₹24,000 | 780 ₹23,400 |
| 3.00Supply and fixing of brass cable gland for following PVC LTUG aluminium armoured cable with earth connection etc.for following sizes of cables etc., complete and as directed by SIPCOT Officers. | |||||
| 3.01 | 4core x 16 sq.mm. Ar. Alu. UG cable ( For street light pole ) | 40 | Nos | 350 ₹14,000 | 350 ₹14,000 |
Tender Value
₹10.0 Cr
EMD Value
₹5.1 L
Closing Date
24 Nov 2025, 3:30 pmClosed
Special Chief Engineer
SIPCOT Head office Egmore chennai
External Development Works of Admin, Creche, Canteen and Medical Facility Building at SIPCOT Mega Leather Park, Panapakkam in Ranipet District. (Package 3A)
2025_SIPCT_622349_1
NIT.No.34/CD/T.No.34/2025-26
Open Tender
Civil Works
SIPCOT Mega Leather Park, Panapakkam
Please refer Tender documents.
15 documents required · 15 mandatory
₹0
₹5.1 L
SIPCOT Head office Egmore chennai
17 Jun 2026
11 Nov 2025
25 Nov 2025
11 Nov 2025
24 Nov 2025
17 Nov 2025
14 Nov 2025
Design, fabrication and installation of simple vault tensile fabric work and Steel structure using Belgian make tensile polyester fabric, steel frames by ISO standard acclaimed CE certified installer with structural stability vetting from Anna university ,Chennai having using FLUOMAX Coated Architectural Membrane having tensile strength not less than 4300 N/50mm/ 4200 N/50mm (Warp/ Weft) and Tear strength not less than 600 N/ 500 N (Warp/ Weft) of make SIOEN Belgium or equivalent, cables, complete perimeter attachment system, and all normally associated components with machines for Fabrication using swiss make Zund cutting machine and Belgian make Architectural Membrane on 20KW Forsstrom High Frequency Welding Machine with SEAMLESS WELDS 50 mm weld width X 1400 mm- Single Stroke all PVC joints shall be formed to a tolerance of +1mm, -1mm and shall be assembled to ensure that seams are always single laid and attaining seamless finish by that a cut edge does not face uphill and membrane used to have a double lacquering made out of highly concentrated FLUOMAX PVDF on both side, double PVC coating and be weldable without grinding to make sure the fabric have less environmental impact the fabricator has to deliver evidence of REAC conformit a per the European Norms the fabric to have Color light fastness not less than >6 Note in accordance with the German standard DIN 54004, DIN EN ISO 105 B02 and have 15 years manufacturer warranty All Fabric supplied and installed shall be in accordance with this specification and shall be guaranteed against water leakage, faulty materials and Mild steel structure supplied are made of high quality pure s teel H R c oil a nd t he t ubes t o conform"
Part A - External Street Light
Plastering with cement mortar 1:5 (One of cement and five of M sand) 12 mm thick finished with neat cement including, providing band cornice, ceiling cornice, inner, outer walls, scaffolding curing etc., complete complying with standard specification and as directed by the SIPCOT Officers.
Supplying and erection of 8m Free Standing Double Arm Bracket 8 sided Octagonally continuously tapered structured pole galvanized iron coated (GI) with minimum coating of not less than 65-75 micron, with 130mm bottom A/F & 70mm at top A/F made up of 3mm thick HT sheet along with base plate of size 250x250x12mm thick including 4 Nos of M24X750mm high "J" type EN8 grade foundation bolts along with template and 1.5mtr long hot dip galvanized Single / double arm bracket made up of 40NB dia GI pipe suitable to mount on pole having top of 70mm A/F and including Bakelite sheet with 1 No 6A SP MCB and stud type connector suitable for 4CX25Sqmm cable etc., complete complying with standard specifications and as directed by SIPCOT officers.
Design, manufacture, testing and inspection at places of manufacturer, and supplying, delivery at site, unloading, storing, transporting directly to site or through transit stores as the case may be, installation, final painting, testing and commissioning of street lighting fixtures suitable for 80 W LED street light fitting with cool day light, made out of pressure die cast aluminium body, separate compartment for LED, including electronic drivers, day light colour LED lamps, inter connecting wiring with suitable fixing clams as required including accessories all inclusive etc., complete complying with standard specifications and as directed by SIPCOT officers.
Providing and laying in position, Standardised Concrete Mix M-25 Grade by insitu machine mix concrete adopting weighing batch method in accordance with IS:456-2000 using 20mm and down graded hard broken granite stone jelly for all RCC items of works with minimum cement content of 350 kglm3 and maximum water cement ratio of 0.50, including admixture (plasticiser / superplasticiser) in recommended proportions as per IS:9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability with about (5.0 Cu.m) 7730 kg. of 20mm machine crushed stone jelly and with about (3.3 Cu.m) 5156 kg. of 10-12mm machine crushed stone jelly and with about (4.79 cu.m’) 7670 kg. of crushed stone sand, but excluding cost of reinforcement grill and fabricating charges, centering and shuttering and also including laying, vibrating with mechanical vibrators, finishing, curing, etc. and providing fixtures like fan clamps in the RCC floor/ roof slabs wherever necessary without claiming extra, etc., complete complying with standard specification and as directed by the SIPCOT Officers. The coarse and fine aggregates to be used should comply with the requirements of IS Standards. (No separate payment will be made by the Department for the excess usage of materials). Foundation and Basment.
4core x 16 sq.mm. Ar. Alu. UG cable ( For street light pole )
3.5core x 70 sq.mm. Ar. Alu. UG cable ( I/C to Feeder pillar box )
Supplying and erecting steel centering including necessary supports for plane surfaces for Reinforced Cement Concrete works such as vertical slab, side slabs of boxing, vertical drops, facia, vertical wall, etc. using mild steel sheets of size 1200cm x 60cm and 10 BG stiffened with welded mild steel angles of size 40mm x 40mm x 5 mm for boarding, laid with silver oak joists of size 10cm x 5cm & 7.5cm x 5cm as support runner, Top Horizontal stiffener spaced at about 60cm to 90cm centre to centre or at suitable intervals. MS Channel Section (ISMC 100) shall be provided as a vertical upport @1.20m C/C and with Lateral support of Steel Adjustable Telescopic Props of Size 2m x 2m (expandable upto 3.60m) & steel pipes of 20mm dia@ required level/spacing etc, complete complying with standard specifcation and as directed by the SIPCOT Officers. (Payment for centering shall be given after the concrete is laid)
4core x 16 sq.mm. Ar. Alu. UG cable ( For street light pole )
3.5core x 70 sq.mm. Ar. Alu. UG cable ( I/C to Feeder pillar box )
Providing and fixing of SFRC manhole cover with frame of size 600mmx600mmincluding necessary masonry work and plastering etc. all complete complying with standard specifications and as directed by SIPCOT Officers.
4core x 16 sq.mm. Ar. Alu. UG cable ( For street light pole )
3.5core x 70 sq.mm. Ar. Alu. UG cable ( I/C to Feeder pillar box )
Providing and laying Cement concrete 1:4:8 (One of cement, four of sand and eight of hard broken stone jelly) for foundation using 40 mm size broken stone jelly inclusive of shoring, strutting, baling out water wherever necessary ramming, curing etc., complete in all respect complying with relevant standard specifications and as directed by the SIPCOT Officers.
Supplying and erecting centering for plane surfaces such as RCC Floor/Roof Beam, Lintels, Cantilever Beams, Bed Blocks etc.. with necessary supports and strutting above 4.90m up to 5.50m height in all floors with all cross bracings using MS Sheets made of 10 gauge thickness welded with MS angle of Size 25mm x 25mm x 3mm for boarding laid over Steel adjustable Span of Size 2m x 2m(expandable up to 3.60m) and Silver Oak Joists of Size 10 x 5 cm spaced at 50cm to 60cm c/c and supported by Steel Adjustable Telescopic Props of Size 3.0 x 3.0m (expandable up to 5.50m) made with outer steel pipe with Dia 50mm (3.60mm thick) and inner steel pipe with Dia 40mm (2.90mm thick) Spaced at not more than 50 to 60cm c/c and with Cross bracings provided at two levels at a spacing of 1.80m etc complete complying with standard specifications. Steel adjustable span and Steel Adjustable telescopic props shall be provided as directed by the SIPCOT Officers. (Payment for centering shall be given after the concrete is laid).
Supplying and erecting centering for plane surfaces such as RCC Floor Slab, Roof Slab, Loft, Landing Slabs, etc with necessary supports and strutting above 4.90m up to 5.50m height in all floors with all cross bracings using MS Sheets made of 10 gauge thick welded with MS angle of Size 25mm x 25mm x 3mm for boarding laid over steel adjustable span of size 2m x 2m (expandable up to 3.60m) and supported by Steel Adjustable Telescopic Props of Size 3.00m x 3.00m (expandable up to 5.50m) made with outer steel pipe with Dia 50mm (3.60mm thick) and inner steel pipe with Dia 40mm (2.90mm thick) with Cross bracings provided at two levels at a spacing of 1.80m etc complete complying with standard specifications. Steel adjustable span and Steel Adjustable telescopic props shall be provided as directed by the SIPCOT Officers (Payment for centering shall be given after the concrete is laid).
Supplying and erecting steel centering including necessary supports For plane surfaces such as rectangular or square RCC columns etc. which require only nominal strutting using mild steel sheets made of 10 gauge thick welded with MS angle size 40mm x 40mm x 5 mm and supported by Steel Adjustable Telescopic Props of Size 2m x 2m (expandable up to 3.60m) made with outer steel pipe with Dia 50mm (3.60mm thick) and inner steel pipe with Dia 40mm (2.90mm thick).etc.. Complete in all floors complying with standard specification. Steel Adjustable telescopic props shall be provided as directed by the SIPCOT Officers. (Payment for centering shall be given after the concrete is laid).
Supplying and erecting steel centering including necessary supports for plane surfaces for Reinforced Cement Concrete works such as vertical slab, side slabs of boxing, vertical drops, facia, vertical wall, etc. using mild steel sheets of size 1200cm x 60cm and 10 BG stiffened with welded mild steel angles of size 40mm x 40mm x 5 mm for boarding, laid with silver oak joists of size 10cm x 5cm & 7.5cm x 5cm as support runner, Top Horizontal stiffener spaced at about 60cm to 90cm centre to centre or at suitable intervals. MS Channel Section (ISMC 100) shall be provided as a vertical support @1.20m C/C and with Lateral support of Steel Adjustable Telescopic Props of Size 2m x 2m (expandable up to 3.60m) & steel pipes of 20mm Dia @ required level/spacing etc. complete complying with standard specification and as directed by the SIPCOT Officers. (Payment for centering shall be given after the concrete is laid
Supplying and fixing Mild Steel grills for windows, Ventilators verandah enclosure, Ladder and gate as per the design approved including one coat of primer and labour for fixing in position etc. all complete complying with relevant standard specification and as directed by the SIPCOT Officers. (The design of grill should be got approved from the SE before use)
Ganolithic flooring with cement concrete 1:1.5:3(1 cement : 1.5 coarse sand : 3 graded stone aggregate 12 to 20 mm nominal size) for an average thickness of 50 mm and applying Nitti floor hard top 5kg/m2 and making smooth and cutting construction grooves etc.,and as directed by the SIPCOT Officers.-AHU & electrical room in terminal building, U.G. Fire sump STP,ramp,idle bus parking at terrace of bus bay and car driveway at ground floor in terminal building and substation.
Streetlight pole foundation cost 8m Pole
Supplying and erecting centering for sides and soffits including necessary supports and strutting up to 3.29 M height for plane surfaces as detailed below in all floors with all cross bracings using Mild Steel sheets of size 90 x 60 cm and 10 BG stiffened with welded Mild Steel angle of size 25mm x 25mm x 3 mm for boarding laid over silver oak joists of size 10cm x 6.50 cm spaced at abote 90 cm centre to centre and supported by casurina props of 10cm to 13 cm dia spaced at not more than 75 cm centre to centre etc., complete complying with the standard specificaiton and as directed by SIPCOT officers. (Payment for centering shall be given after the concrete is laid)
Plastering with Cement Mortar 1:5 (One cement and Five Plastering sand), 12mm thick in all floors including mortar plasticizer at 200ml per 50Kg of cement used, curing etc. complete complying with standard specification and as directed by the SIPCOT Officers
Earth work excavation for foundation by manual means for Isolated, Combined and Other type foundations in all soils and sub-soils and to full depth as may be directed except in rock requiring blasting inclusive of shoring shuttering, bailing out water wherever necessary and depositing the surplus earth within the compound in places shown by the SIPCOT Officers with an initial lead of 10 mts and initial lift of 2.00mts. and clearing and levelling the site, etc., complete complying with standard specification and as directed by
Part - B - External Power Distribution
Finishing the top of roof slab with one course of hydraulically pressed tile of approved superior quality of size 23 cmx23cm, 20mm thick laid over weathering course in cement mortar 1:3 (One of cement and three of sand) 12mm thick, mixed with water proofing compound at 2% by weight of cement used and pointed neatly with the same cement mortar mixed with water proofing compound including curing etc., complete in all respects complying with relevant standard specifications and as directed by the SIPCOT Officers.
Painting with two coats of newly plastered wall surface with ready mixed plastic emulsion paint of first class quality and of approved colour over a priming coat including thorough scrapping, clean removal of dirt, priming coat and including necessary plaster of paris putty, wherever required etc., complete at alllevels complying with standard specification. and as directed by the SIPCOT Officers (paints and its shade shall be got approved from the EE before using)
Supplying and erecting pull and push type rolling shutter (Gear operated type) with ISI mark of approved size and using 18 gauge GI sheet including one coat of best approved quality redoxide primer, hood covers transportation charges all taxes labour charges for making and fixing, etc., all complete complying with relevant standard specification and as directed by the SIPCOT Officers.
Supplying and erecting steel centering including necessary supports for plane surfaces for Reinforced Cement Concrete works such as vertical slab, side slabs of boxing, vertical drops, facia, vertical wall, etc. using mild steel sheets of size 1200cm x 60cm and 10 BG stiffened with welded mild steel angles of size 40mm x 40mm x 5 mm for boarding, laid with silver oak joists of size 10cm x 5cm & 7.5cm x 5cm as support runner, Top Horizontal stiffener spaced at about 60cm to 90cm centre to centre or at suitable intervals. MS Channel Section (ISMC 100) shall be provided as a vertical support @1.20m C/C and with Lateral support of Steel Adjustable Telescopic Props of Size 2m x 2m (expandable upto 3.60m) & steel pipes of 20mm dia @required level/spacing etc. complete complying with standard specification and as directed by the SIPCOT Officers. (Payment for centering shall be given after the concrete
is laid)
Supply of HT Earth Discharge Rod etc. complete and as directed by SIPCOT Officers.
Supplying and filling with 40mm size Hard broken stone jelly in foundation and basement and other similar works including cost of materials, labour charges, etc., all complete and as directedby the SIPCOT Officers.
Supplying and erecting steel centering including necessary supports For plane surfaces such as rectangular or square RCC columns etc. which require only nominal strutting using mild steel sheets made of 10 gauge thick welded with MS angle size 40mm x 40mm x 5 mm and supported by Steel Adjustable Telescopic Props of Size 2m x 2m (expandable up to 3.60m) made with outer steel pipe with Dia 50mm (3.60mm thick) and inner steel pipe with Dia 40mm (2.90mm thick).etc.. Complete in all floors complying with standard specification. Steel Adjustable telescopic. props shall be provided as directed by the SIPCOT Officers. (Payment for centering shall be given after the concrete is laid).
Supply and fixing of brass cable gland for following PVC LTUG aluminium armoured cable with earth connection etc.for following sizes of cables etc., complete and as directed by SIPCOT Officers.
Supply and providing cable end termination of following size PVC LTUG aluminium armoured cable with necessary aluminium cable sockets by crimping etc with electrical connection complete etc., complete and as directed by SIPCOT Officers.
Part - M - Tensile Roof for Admin Building OTS Area.
3.5 core x 400 sq.mm. Ar. Alu. UG cable
3.5 core x 240 sq.mm. Ar. Alu. UG cable
3.5 core x 70 sq.mm. Ar. Alu. UG cable
3.5 core x 35 sq.mm. Ar. Alu. UG cable
Supplying, fabricating and placing in position Mild Steel / Ribbed Tor Steel reinforcement grills of all variety like HYSD/CTD/TMTand all grade like Fe 500, Fe550D, Fe 500 D etc., for all RCC works as per design given including cost of steel reinforcement and G.I. binding wire, wastage etc. complete complying with standard specification and as directed by the SIPCOT Officers.(Contractor has to make his own arrangements for the supply of steel reinforcement and binding wire) Upto Plinth / Basment Level.
Part - M - Tensile Roof for Admin Building OTS Area.
3.5 core x 400 sq.mm. Ar. Alu. UG cable
3.5 core x 240 sq.mm. Ar. Alu. UG cable
3.5 core x 70 sq.mm. Ar. Alu. UG cable
3.5 core x 35 sq.mm. Ar. Alu. UG cable
Supply and laying of the following size of PVC armoured LTUG cable in a trench to be excavated at a depth of 0.75 metre putting 0.15 metre layer of sand and covering the three sides of the cable and refilling the earth to make good etc., complete and as directed by SIPCOT SIPCOT Officers.
Part - M - Tensile Roof for Admin Building OTS Area.
3.5 core x 400 sq.mm. Ar. Alu. UG cable
3.5 core x 240 sq.mm. Ar. Alu. UG cable
3.5 core x 70 sq.mm. Ar. Alu. UG cable
3.5 core x 35 sq.mm. Ar. Alu. UG cable
Supply of Fire Extinguisher Co2, 4.5 kg. confirming to TAC Norms etc. complete and as directed by SIPCOT Officers.
Supply & fixing of Coil earth to street light poles with No.8 SWG GI wire of 11.5 metres of length in which 10 metres of total length compressed in to a coil of one meter length (75mm to 100mm dia) connected suitable with hexagonal earth bolt of size 8mm in to 25mm welded on the pole at one end with a coil position fixed on the earth etc., complete and as directed by SIPCOT Officers.
Supply and fixing of brass cable gland for following PVC LTUG aluminium armoured cable with earth connection etc.for following sizes of cables etc., complete and as directed by SIPCOT SIPCOT Officers.
Supply and providing cable end
termination of following size PVC LTUG aluminium armoured cable with necessary aluminium cable sockets by crimping etc with electrical connection complete etc., complete and as directed by SIPCOT SIPCOT Officers.
Supply & fixing of Coil earth to street light poles with No.8 SWG GI wire of 11.5 metres of length in which 10 metres of total length compressed in to a coil of one meter length (75mm to 100mm dia) connected suitable with hexagonal earth bolt of size 8mm in to 25mm welded on the pole at one end with a coil position fixed on the earth etc., complete and as directed by SIPCOT SIPCOT Officers.
Supply of HT Rubber hand gloves as per the norms etc. complete and as directed by SIPCOT Officers.
Supply of Metallic Danger Board as required by the Electrical Authorities as per the norms etc. complete and as directed by SIPCOT Officers.
Cement Concrete 1:3:6 (One Cement, Three crushed stone sand and Six broken stone jelly) using 20mm size hard broken stone jelly for dummy columns,etc., excluding cost of centering shuttering reinforcement grills and fabrication charges but including Cost of Mortar Plasticizer, curing etc. complete and as directed by the SIPCOT Officers. (Dummy columns should be at least 1 metre height)-Mixing by mechanical means etc complete in all respects and as directed by SIPCOT SIPCOT Officers
Supply, installation, testing & Commissioning of Earthing as per PWD standard with an electrode of 2.10 metre class 'B' GI pipe of die not less than 40mm with copper earth plate of size 125mmx50mmx6mm with necessary funnelling arrangements and masonry works and 38mm RCC Cover slab for brick masonry etc., complete and as directed by SIPCOT SIPCOT Officers.
Supply and run of 25mm x 6mm Flat Down Conductor with necessary clamps / supports on wall / floor / ground for earth connection etc., complete and as directed by SIPCOT SIPCOT Officers.
Supply and installation of PVC Rigid Pipe 50mm (2") including laying charges in street light pole foundation for power cable entry. Complete, as per standard specification etc., complete and as directed by SIPCOT SIPCOT Officers.
Supply & installation of Cable route markers made of galvanised CI circular 100 mm. dia. with "LT/HT CABLE" markers on same by 30 mm. size letter. The cable marked shall be firmly installed with 450 mm anchoring below ground level etc., complete and as directed by SIPCOT SIPCOT Officers.
LT Cable and End Termination Supply and laying of the following PVC armoured LTUG cable in a trench to be excavated at a depth of 0.75 metre putting 0.15 metre layer of sand and covering the cable completely with bricks and sand and refilling the earth to make good etc. complete and as directed by SIPCOT Officers.
Supply and fixing of brass cable gland for following PVC LTUG aluminium armoured cable with earth connection etc.for following sizes of cables etc. complete and as directed by SIPCOT Officers.
Part - C - External CCTV Surveillance System
Supply, installation, testing & Commissioning of Earthing as per PWD standard with an electrode of 2.10 metre class 'B' GI pipe of die not less than 40mm with copper earth plate of size 125mmx50mmx6mm with necessary funnelling arrangements and masonry works and 38mm RCC Cover slab for brick masonry etc., complete and as directed by SIPCOT Officers.
Supply and run of 25mm x 6mm Flat Down Conductor with necessary clamps / supports on wall / floor / ground for earth connection etc., complete and as directed by SIPCOT Officers.
Supply and installation of PVC Rigid Pipe 50mm (2") including laying charges in street light pole foundation for power cable entry. Complete, as per standard specification etc., complete and as directed by SIPCOT Officers.
Supply ,Excavation and laying of HDPE Pipe 120mm / 103.50mm for electrical cable laying road crossing etc., complete and as directed by SIPCOT Officers.
Supply & installation of Cable route markers made of galvanised CI circular 100 mm. dia. with "LT/HT CABLE" markers on same by 30 mm. size letter. The cable marked shall be firmly installed with 450 mm anchoring below ground level etc., complete and as directed by SIPCOT Officers.
Supply & installation of 300mm dia RCC Hume Pipe for electrical cable laying below ground level etc., complete and as directed by SIPCOT Officers.
Supply, installation, & commissioning of Providing 11kV Double Pole Structure with AB Switch 12kV, 630A, 26.3kA for 3sec, 3-ph, 3 Pin type, Vertical/ Horizental Mounting type, Gang Operated, AB Switch along with Support Insulators, Base Channel down Pipe, Arcing Horns etc. complete as per technical specifications, scope of works and approved drawings on Poles as per technical specification, approved drawings and scope of work. etc,...complete as directed and approved by SIPCOT Officers.
Supply, installation, testing & commissioning HT Metering Sets with 11KV metering cubicles 11 KV set , 10/5A., accuracy 0.2 S covers design, fabrication, manufacture, painting, testing of 11KV metering cubicles for HT consumers with 0.2S class 11 KV CTs & PTs bushings, connecting bus bars, control cables duly terminated suitable for supply energy measurement system and for indoor as well as outdoor application etc. complete as directed and approved by SIPCOT Officers.
Design, engineering, manufacture, assembly, supply, erection, installation, testing, and commissioning of an 11 kV, 630A, 25 kA (for 3 seconds) HT Vacuum Circuit Breaker (VCB) panel, complete as per specification, shall be both auto and manual operated. The VCB panel shall be suitable for terminating a 3-core 11 kV HT XLPE cable for incoming and outgoing connections, with all necessary accessories and protection as per the standards. It shall be designed for installation in a three-phase, three-wire, 11 kV, 50 Hz AC distribution network with digital metering system with RS485 port and suitable class-1 CTs& PTs complete with all accessories and erected on the provided foundation as per specification and standards etc, complete as directed and approved by the SIPCOT Officers at the site.
Supply, installation, testing & commissioning of 1250 kVA, 11 kV/433 V ONAN Outdoor Transformer (As per ISI 1180-Level 1), (Copper winding) Energy Efficient Level - 1 oil immersed ONAN cooled, core type continuous rating, outdoor distribution power transformer with copper winding for voltage ratio 11 KV/433 volts between phases with neutral brought out at LV side. The transformer shall be contained in a mild steel plain & radiator cooled tank, conforming to IS 1180 (Part I) of 2014 with on-load tap switch for ±10% on L.V side and ±5 % on H.V.side. The transformer shall be supplied with all accessories for Plinth Mounted Transformer such as HT & LT Cable Entry Boxes, Copper Extension for Cable End Termination for HT & LT sides, Bucholz Relay, Marshaling Box, Wheels, Channels etc., first filling of oil and consisting of all the fittings and accessories such as Inspection cover, Oil level indicator with minimum and filling level markings, on load tap changing switch with locking device & keys, H.V. Terminals- Bushings, L.V. Terminals cable box, Rating plate, Two earthing terminals, Two lifting hooks etc complete as per IS 1180 (Part I) and as amended thereafter etc. complete as directed and approved by SIPCOT Officers
Supply & Laying of 3 Core X 300 sq.mm. HT XLPE 11KV (E) insulated aluminium armoured cable in ground up to 1200 mm deep, 500 mm wide cable trench providing sand cushioning before and after laying cable and covering with Layer of sand covering the three sides of the cable with bricks and refilling the earth to make it good as per technical specification, approved drawings and scope of work etc. complete as directed and approved by SIPCOT Officers.
Supplying and fixing of 20 Metre HDMI Cable with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.
Providing and fixing G.I. chain link fabric fencing of required width in mesh size 50x50 mm including strengthening with 2 mm dia wire or nuts, bolts and washers as required complete as directed by the SIPCOT SIPCOT Officers
Supply and fixing of sheet steel enclosure for MCBs with 32A 4P MCB, including all required connections for emergency lighting control, complete as directed and approved by the SIPCOT Officers
Supply and providing cable end termination of following size PVC LTUG aluminium armoured cable with necessary aluminium cable sockets by crimping etc with electrical connection complete etc. complete and as directed by SIPCOT Officers.
Part - D - Storm Water Drain
Design, manufacture, supply, erection, testing and commissioning of 415 V streetlight service feeder pillar panel 1200mm x 900mm x 300mm suitable for outdoor installation, made up of CRCA sheet steel of thickness not less than 2 mm with a weather proof canopy of top, double door construction, IP 55 protection, with 2 coat of primer and 2 coats of aluminium finish with 1no. 125 A TPN MCCB with 16 kA breaking capacity in the incoming and 8 nos 32 A, TPN contactor 10 nos. 40A TPN MCB, 12nos, 10A SP MCB as outgoing, automatic dawn and dusk with cyclic timer control for street light outgoing and adequate plate to terminate suitable cable as incomer and suitable cable as outgoing. energy saver for automatic switching ON/OFF as per pre-sets time cycle, digital multifunctional meter with RS485 port and suitable CT etc. including the pillar to be erected with suitable angle iron frame pedestal with concrete grouting etc., complete and as directed by SIPCOT officers.
Supplying and erecting steel centering including necessary supports for plane surfaces for Reinforced Cement 50 Concrete works such as column footings, column pedestals, plinth beams, grade beams, staircase steps, Sal slabs etc. which require only nominal strutting using mild steel sheets of size 90cm x 60cm and 10 BG stiffened with welded mild steel angles of size 25mm x 25mm x 3 mm for boarding, laid with silver oak joists of size 10cm x 5cm & 7.5cm x 5cm as support runner vertical stiffener, side support and Top Horizontal stiffener spaced at about 60cm to 90cm centre to centre or at suitable intervals etc. complete in all floors complying with standard specifcation. (Payment for centering shall be given after the concrete is laid).
Cement Concrete 1:4:8 (One Cement, four crushed stone sand and Eight hard broken stone jelly) using 40 mm gauge hard broken granite stone jelly for foundation including dewatering wherever necessary and laid in layers of not more than 15 cm thick well rammed, consolidated and including curing etc. complete complying with standard specification and as directed by the SIPCOT Officers -Mixing by mechanical means
Manufacturing, supplying and fixing in position Reinforced Cement concrete perforated precast slab of 100 mm thick in Cement Concrete M25 grade including cost of moulding charges, casting of slab, finishing, curing, placing etc. all complete complying with standard specifications and as directed by "SIPCOT" officers..( At pedestrian crossing)
Part - E - Box Culvert (Internal Drain)
the SIPCOT Officers.
Supplying and erecting steel centering including necessary supports for plane surfaces for Reinforced Cement 50 Concrete works such as column footings, column pedestals, plinth beams, grade beams, staircase steps, Sal slabs etc. which require only nominal strutting using mild steel sheets of size 90cm x 60cm and 10 BG stiffened with welded mild steel angles of size 25mm x 25mm x 3 mm for boarding, laid with silver oak joists of size 10cm x 5cm & 7.5cm x 5cm as support runner vertical stiffener, side support and Top Horizontal stiffener spaced at about 60cm to 90cm centre to centre or at suitable intervals etc. complete in all floors complying with standard specifcation. (Payment for centering shall be given after the concrete is laid).
Change over switch:Supply and fixing of 250 Amps Three Phase 4 Pole Change Over Switch on suitable angle iron frame work with MS cable entry boxes for incoming and outgoing earthing etc.complete as directed and approved by SIPCOT Officers.
Cement Concrete 1:4:8 (One Cement, four crushed stone sand and Eight hard broken stone jelly) using 40 mm gauge hard broken granite stone jelly for foundation including dewatering wherever necessary and laid in layers of not more than 15 cm thick well rammed, consolidated and including curing etc. complete complying with standard specification and as directed by the SIPCOT Officers -Mixing by mechanical means
Providing and laying in position, standardised concrete Mix M-20 Grade by insitu machine mix concrete adopting weighing batch method in accordance with IS 456 using 20mm and down graded hard broken granite stone jelly for all RCC items of works with minimum cement content of 325 kg/m3 and maximum water cement ratio of 0.55, including admixture (plasticiser / super plasticiser) in recommended proportions as per IS:9103 to accelerate, retard setting of concrete, improve workability without inspiring strength and durability with about (5 Cu.m) 7730 kg. of 20mm machine crushed stone jelly and with about (3.3 Cu.m) 5156 kg. of 10-12mm machine crushed stone jelly and with about (4.79 cu.m) 7670 kg. of crushed stone sand, but excluding cost ofreinforcement grill and fabricating charges, centering and shuttering and also including laying,vibrating with mechanical vibrators, finishing, curing, etc. and providing fixtures like fan clamps in the RCC floor/ roof slabs wherever necessary without claiming extra, etc.,complete complying with standard specification and as directed by the SIPCOT Officers. The coarse and fine aggregates to be used should comply with the requirements of IS standards. (No separate payment will be made by the Department for the excess usage of materials). Foundation and Basement.
Part - F - Paver Finish in Driveway, Footpath.
Manufacturing, supplying and fixing in position plain cement concrete precast kerb stone Size of 600 x 325 x 165mm and Design in Cement Concrete 1:3:6 (One cement, three sand and six jelly) using 20mm HBG stone jelly including cost of moulding charges, casting of slab, finishing, curing, fixing and pointing the slab with CM 1:3 (One Cement and Three Sand) to full depth of kerb and the shape of kerb stone as per drawing, the cost including manufacturing, transportation, laying in position, curing etc., complete complying with standard specification
Supplying, fabricating and placing in position Mild Steel / Ribbed Tor Steel reinforcement grills of all variety like HYSD/CTD/TMTand all grade like Fe 500, Fe550D, Fe 500 D etc., for all RCC works as per design given including cost of steel reinforcement and G.I. binding wire, wastage etc. complete complying with standard specification and as directed by the SIPCOT Officers.(Contractor has to make his own arrangements for the supply of steel reinforcement and binding wire)
Construction of Granular Sub - Base (GSB) to the required compacted thickness (Drainage layer) by providing approved Coarse graded material conforming to Grading-V of Table 400 - 1 and satisfying the physical requirement for material for GSB as per Table 400 - 2 of MORTH Rev -5 including screening, spreading in uniform layers with motor grader on prepared surface, watering and premixing by mix in place method with rotavator at OMC, and compacting with Vibratory roller 80 to 100 KN static weight to achieve the desired density and fine dressing to required grade and cross slope as directed by the SIPCOT officers etc., complete including obtaining and transporting all materials from approved quarry site to work site with all lift and lead by mechanical transport, head load or any other mode of transporation including cost and conveyance of all materials, labour charges,hire charges and fuel charges for loader, water tanker with sprinkler,motor grader, vibratory road rollers and all other equipments, tools and plants, safety measures, testing required including all other incidental charges, etc., complete as per the standard specification as per clause 401 of MORTH Rev.-5 and as directed by the SIPCOT officers.
Providing, laying, spreading and compacting graded stone aggregates for Wet Mix Macadam 250mm thick, including premixing the materials with water at OMC in mechnanical mix plant, conveyance of mixed materials by tipper to site, laying in uniform layers using pavers in Sub Base/ Base course on well prepared surface and compacting with vibratory roller to acheive the desired density including cost of material, labour charges, rentals for machinery, fuel and all other incidental charges etc., complete as per clause 406 of MORTH Rev-5
Providing and laying in position, Standardised Concrete Mix M-25 Grade by insitu machine mix concrete adopting weighing batch method in accordance with IS:456-2000 using 20mm and down graded hard broken granite stone jelly for all RCC items of works with minimum cement content of 350 kglm3 and maximum water cement ratio of 0.50, including admixture (plasticiser / superplasticiser) in recommended proportions as per IS:9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability with about (5.0 Cu.m) 7730 kg. of 20mm machine crushed stone jelly and with about (3.3 Cu.m) 5156 kg. of 10-12mm machine crushed stone jelly and with about (4.79 cu.m’) 7670 kg. of crushed stone sand, but excluding cost of reinforcement grill and fabricating charges, centering and shuttering and also including laying, vibrating with mechanical vibrators, finishing, curing, etc. and providing fixtures like fan clamps in the RCC floor/ roof slabs wherever necessary without claiming extra, etc., complete complying with standard specification and as directed by the SIPCOT Officers. The coarse and fine aggregates to be used should comply with the requirements of IS Standards. (No separate payment will be made by the Department for the excess usage of materials). Foundation and Basement
Supplying, fabricating and placing in position Mild Steel / Ribbed Tor Steel reinforcement grills of all variety like HYSD/CTD/TMTand all grade like Fe 500, Fe550D, Fe 500 D etc., for all RCC works as per design given including cost of steel reinforcement and G.I. binding wire, wastage etc. complete complying with standard specification and as directed by the SIPCOT Officers.(Contractor has to make his own arrangements for the supply of steel reinforcement and binding wire) Upto Plinth / Basement Level
Providing and laying in position, standardised concrete Mix M-20 Grade by insitu machine mix concrete adopting weighing batch method in accordance with IS 456 using 20mm and down graded hard broken granite stone jelly for all RCC items of works with minimum cement content of 325 kg/m3 and maximum water cement ratio of 0.55, including admixture (plasticiser / super plasticiser) in recommended proportions as per IS:9103 to accelerate, retard setting of concrete, improve workability without inspiring strength and durability with about (5 Cu.m) 7730 kg. of 20mm machine crushed stone jelly and with about (3.3 Cu.m) 5156 kg. of 10-12mm machine crushed stone jelly and with about (4.79 cu.m) 7670 kg. of crushed stone sand, but excluding cost ofreinforcement grill and fabricating charges, centering and shuttering and also including laying,vibrating with mechanical vibrators, finishing, curing, etc. and providing fixtures like fan clamps in the RCC floor/ roof slabs wherever necessary without claiming extra, etc.,complete complying with standard specification and as directed by the SIPCOT Officers. The coarse and fine aggregates to be used should comply with the requirements of IS standards. (No separate payment will be made by the Department for the excess usage of materials). Foundation and Basement.
Part - G - Site Grading
Painting New Plastered Wall Surface with Two finishing coats of
ready mixed (Emulsion) of approved quality and colour over one coat priming coat in all floors including the cost of primer etc., complete complying with standard specification and as directed by the SIPCOT Officers.(The make, quality and colour of paint should be got approved by the Executive Engineer before use on works.)
Part - H - Fencing
1 PHASE UPS:Supply erection, testing, commissioning of The UPS shall be 1 Phase, 3 kVA, 230 V,50 Hz , online PWM with IGBT, suitable for continuous duty as per IEC/IS standards, delivering regulated, distortion-free, uninterrupted power with ≥90% efficiency at full load. It shall include comprehensive protections, audible alarms for fault and low-battery, and SMF lead-acid batteries of reputed make providing minimum 1-hour backup at full load. The system shall be complete with input/output MCBs, neutral link, double earthing as per IS 3043, and all required cabling and accessories for safe and reliable operation etc,. complete as directed and approved by SIPCOT Officers.
Supplying and laying of Interlocking Paver Block Stone 83mm thick, Over a base layer of 80mm crushed stone sand filling. including cost of Paver,crushed stone sand, laying and Labour charges etc complete complying with the standard specification and as directed by the SIPCOT Officers.
Supply, installation, testing & Commissioning of Earthing as per PWD standard with an electrode of 2.10 metre class 'B' GI pipe of die not less than 40mm with copper earth plate of size 125mmx50mmx6mm with necessary funnelling arrangements and masonry works and 38mm RCC Cover slab for brick masonry etc. complete and as directed by SIPCOT Officers.
Supply and run of 50mm x 6mm GI Flat Down Conductor with necessary clamps / supports on wall / floor / ground for earth connection etc. complete and as directed by SIPCOT Officers.
Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer etc. all complete complying with standard specifications and as directed by "SIPCOT" officers..
Supplying and laying of Interlocking Paver Block Stone 63mm thick Over a 80mm tk base layer of crushed stone sand filling incl. Cost of materials laying and Labour charges etc complete complying with the standard specification and as directed by the SIPCOT Officers.
Supplying and filling in foundation, basement, etc with filling Stone dust/Quarry dust in layers of not more than 15 cm thick well watered, rammed and consolidated etc. complete complying with standard specification and as directed by the SIPCOT Officers.
Foundation and basement
In Ground floor
Supplying and erecting steel centering including necessary supports for plane surfaces for Reinforced Cement Concrete works such as column footings, column pedestals, plinth beams, grade beams, staircase steps, Sill slabs etc. which require only nominal strutting using mild steel sheets of size 90cm x 60cm and 10 BG stiffened with welded mild steel angles of size 25mm x 25mm x 3 mm for boarding, laid with silver oak joists of size 10cm x 5cm & 7.5cm x 5cm as support runner, vertical stiffener, side support and Top Horizontal stiffener spaced at about 60cm to 90cm centre to centre or at suitable intervals etc. complete in all floors complying with standard specifcation. (Payment for centering shall be given after the concrete is Laid)
Brick work in Cement Mortar 1:5 using best quality II Class Ground Moulded Chamber Burnt Bricks of size - 9" x 41/2" x 3" with Class Designation of 7.5 conforming to IS 1077-1992 for foundation and basement including Cost of Mortar Plasticizer curing, etc.,complete complying with standard specification and as directed by the SIPCOT Officers. Brickwork shall be done as per IS 2212-1991 adopting English Bond generally.other type of bond shall be done as directed by the Executive SIPCOT Officers.
Providing and laying in position, standardised concrete Mix M-20 Grade by insitu machine mix concrete adopting weighing batch method in accordance with IS 456 using 20mm and down graded hard broken granite stone jelly for all RCC items of works with minimum cement content of 325 kg/m3 and maximum water cement ratio of 0.55, including admixture (plasticiser / super plasticiser) in recommended proportions as per IS:9103 to accelerate, retard setting of concrete, improve workability without inspiring strength and durability with about (5 Cu.m) 7730 kg. of 20mm machine crushed stone jelly and with about (3.3 Cu.m) 5156 kg. of 10-12mm machine crushed stone jelly and with about (4.79 cu.m) 7670 kg. of crushed stone sand, but excluding cost ofreinforcement grill and fabricating charges, centering and shuttering and also including laying,vibrating with mechanical vibrators, finishing, curing, etc. and providing fixtures like fan clamps in the RCC floor/ roof slabs wherever necessary without claiming extra, etc.,complete complying with standard specification and as directed by the SIPCOT Officers. The coarse and fine aggregates to be used should comply with the requirements of IS standards. (No separate payment will be made by the Department for the excess usage of materials). Foundation and Basement.
Earth work excavation for foundation by manual means for Isolated, Combined and Other type foundations in all soils and sub-soils and to full depth as may be directed except in rock requiring blasting inclusive of shoring shuttering, bailing out water wherever necessary and depositing the surplus earth within the compound in places shown by the SIPCOT Officers with an initial lead of 10 mts and initial lift of 2.00mts. and clearing and levelling the site, etc., complete complying with standard specification and as directed by
Part - I - External Firefighting
Supply, erection, testing, commissioning of 1250kVA, 415 V, 3 phase, 50 Hz, DG Set suitable for synchronisation with diesel engine at 1500 RPM coupled with alternator mounted on a channel Iron base frame, fuel tank of adequate capacity, starting batteries with leads, AMF panel, hospital type silencer, with acoustic enclosure , control panel, inter connecting control cable, cable end terminatio
n, including lubrication system, cooling system, all inclusive. DG set should comply with conforming to CPCB II Norms and BIS Specifications or as per the latest amendment (protection) rules, etc.complete as directed and approved by SIPCOT Officers.
Design, manufacture, supply, erection, testing and commissioning of main Power panel suitable for 433Volts 3Phase 4wire system, indoor/outdoor installation, made up of CRCA sheet steel of thickness not less than 2 mm with a weather proof canopy of top, double door construction, IP 55 protection, anti corrosive chemical resistant paint dust & vermin proof, cubicle type, floor mounted, undrilled gland plates at top / bottom, complete with internal wiring, ferrules, name plates,Locking System with inned Copper Busbar with heat shirnkable colour coded sleeve with SMC Bus bar supports with with 2200A, 65 kA, TPN 50 Hz, copper bus bars Busbar size: Phase: 2R X 75 X 12mm, Neutral : 2R X 75 X 12mm Panel should be fully comply to IEC 61439 part 1 & 2 of type tested assembly. The panel should have IncomerIncomer:2Nos - 2000A, 4P, 65kA Drawout type, motor operated ACB with Microprocessor based releases (with Over current / Earth fault / Short circuit ) & Trip & close Coil with Under Voltage releases, high speed closing feature with earthing, door interlock, automatic safety shutters to shroud the bus bar side and FRP sheet barrier on the incoming & outgoing cable sides of the circuit breaker with Electrical & mechanical Interlock with individual Metering for Each Incomer: Load Manager with RS485 Interface with Maxmimum Demand Indication + controller, Bus coupler:2000A, 4P, 65kA Drawout type, motor operated ACB with Microprocessor based releases high speed closing feature with earthing, door interlock, automatic safety shutters to shroud the bus bar side and FRP sheet barrier on the incoming & outgoing cable sides of the circuit breaker with associated protections MCB's, R,Y,B Phase Indicating lamps and control circuit as required and energy meter for out going feeders etc.Out going:800A 50KA 4P ACB with Microprocessor based EDO Breaker - 2no: 400A 36KA 4P Microprocessor based MCCB.- 3Nos 250A 36KA 4P Microprocessor based MCCB.- 2Nos 160A 36KA 4P Microprocessor based MCCB.- 2Nos 125A 36KA 4P Microprocessor based MCCB.- 2Nos with digital multifunctional meter with RS485 port and suitable CT etc. including concrete pedestal and associated civil works etc. complete and as approved and directed by engineer in-charge.
Brick work in Cement Mortar 1:6 using best quality II Class Ground Moulded Chamber Burnt Bricks of size - 9" x 41/2" x 3" with Class Designation of 7.5 c
250 mm dia
150 mm dia
65 mm dia
onforming to IS 1077-1992 for foundation and basement including Cost of Mortar Plasticizer curing, etc.,complete complying with standard specification and as directed by the SIPCOT Officers. Brickwork shall be done as per IS 2212-1991 adopting English Bond generally.other type of bond shall be done as directed by the Executive SIPCOT Officers.
250mm dia
150mm dia
Light and fan point wiring Wiring with 2 x1.5 sq.mm. PVC insulated single core unsheathed FRLSH copper conductor of 1100 V grade in suitable PVC/MS rigid pipe concealed in wall and open as required and ceiling with accessories,ceiling rose and round sheet with flexible hose, Module GI switch box in flush with wall with 6A one way module switch with module front plate with continuous earth wire connection of 1.5 sq.mm copper wire and making good of the concealed portion with suitable colour for Concealed PVC Light point / fan point etc.complete as directed and approved by SIPCOT Officers.
200mm dia
150 mm dia
Supply and laying of the following PVC armoured LTUG cable in a trench to be excavated at a depth of 0.75 metre putting 0.15 metre layer of sand and covering the cable completely with bricks and sand and refilling the earth to make good etc. complete and as directed by SIPCOT Officers.
Supply erection, testing, commissioning of 1 PHASE, 3 KVA, UPS WITH BATTERY - 1 HOUR BACKUP with earth connection etc.complete as directed and approved by SIPCOT Officers.
SPNDB:( LDB & PDB )Supply and fixing of 8 way single pole and neutral MCB sheet steel enclosure distribution board with double door (metal) with 1 no. 32A DP MCB as incoming and 6 nos. 6A to 32A SP MCB as outgoing on suitable in wall with earth etc.complete as directed and approved by SIPCOT Officers.
250mm dia
150mm dia
SPNDB:( ELDB )Supply and fixing of 8 way single pole and neutral MCB sheet steel enclosure distribution board with double door (metal) with 1 no. 32A DP MCB as incoming and 6 nos. 6A to 32A SP MCB as outgoing on suitable in wall with earth etc.complete as directed and approved by SIPCOT Officers.
300 mm dia
Supply and fixing of 4 way Vertical Triple pole and neutral MCB sheet steel enclosure distribution board with double door with 1 no. 63A 4P MCB as incoming and 6A to 32A SP MCB as outgoing on suitable angle iron frame on wall with earth connection etc.complete as directed and approved by SIPCOT Officers.
Brick work in Cement Mortar 1:6 using best quality II Class Ground Moulded Chamber Burnt Bricks of size - 9" x 41/2" x 3" with Class Designation of 7.5 c
150mm dia
100mm dia
onforming to IS 1077-1992 for foundation and basement including Cost of Mortar Plasticizer curing, etc.,complete complying with standard specification and as directed by the SIPCOT Officers. Brickwork shall be done as per IS 2212-1991 adopting English Bond generally.other type of bond shall be done as directed by the Executive SIPCOT Officers.
150mm dia
100mm dia
Light and fan point wiring Wiring with 2 x1.5 sq.mm. PVC insulated single core unsheathed FRLSH copper conductor of 1100 V grade in suitable PVC/MS rigid pipe concealed in wall and open as required and ceiling with accessories,ceiling rose and round sheet with flexible hose, Module GI switch box in flush with wall with 6A one way module switch with module front plate with continuous earth wire connection of 1.5 sq.mm copper wire and making good of the concealed portion with suitable colour for Concealed PVC Light point / fan point etc.complete as directed and approved by SIPCOT Officers.
150 mm dia
Supply, installation, testing, commissioning of 5MP(2560×1920 Pixel) IP Bullet camera Optical Zoom:12X-16X,Field of View (Degree):more than 90-105, Focal length:3.3 mm – 10.2 mm suitable for indoor application, Smart Analytics, IR illumination Range(meter): 30M, Supported Protocols:HTTP,HTTPS,DNS,DDNS,TCP/IP,IPv4,IPv6,IEEE 802.1 all inclusive necessary supports for installation completion as per the recommended and approved by the SIPCOT Officer
Power point wiring with GI box, socket & switch Wiring with 2 x 2.5 sq.mm. PVC insulated single core unsheathed FRLS copper conductor of 1100 V grade in suitable heavy gauge PVC/MS conduit pipe Concealed in wall and open as required with accessories with suitable Module GI switch box in flush wall with 1 no. 6A one way module switch and 1 no. 6A 5 pin module socket with module front plate with painting of Suitable colour with continuous earth wire connection of 2.5 sq.mm copper wire and making good of the concealed portion with painting of suitable colour for Concealed etc.complete as directed and approved by SIPCOT Officers.
Circuit main wiring Supply and Run of 2 of 2.5 sq.mm. PVC insulated SC unsheathed FRLS copper conductor of 1100 V grade in suitable conduit pipe concealed in wall and ceiling with continuous earth wire connection of 2.5 sq. mm copper wire with painting of suitable colour etc.complete as directed and approved by SIPCOT Officers.
Light Fixtures and fan Supply, installation, testing and commissioning of 40W,industrial typy heavy duty 4ft LED light fitting with cool day light made out of CRCA powder coated body, aluminium reflectors, poly carbonate diffuser, glare free light, suitable for surface mounting including electronic drivers, day light colour LED lamps, inter connecting wiring including accessories all inclusive etc. complete and as directed by SIPCOT Officers.
LT Cable and End Termination Supply and laying of the following PVC armoured LTUG cable in a trench to be excavated at a depth of 0.75 metre putting 0.15 metre layer of sand and covering the cable completely with bricks and sand and refilling the earth to make good etc. complete and as directed by SIPCOT Officers. From Electrical room VTPNDB to SPNDB-
Supply, installation, testing, commissioning of 5MP PTZ IP Camera 360 Degree, 200m IR, IP66, Audio In / Out, Alerts, Auto Tracking Optical Zoom:30X,Field of View (Degree):360, suitable for indoor application, Smart Analytics, Supported Protocols:HTTP,HTTPS,DNS,DDNS,TCP/IP,IPv4,IPv6,IEEE 802.1 all inclusive necessary supports for installation completion as per the recommended and approved by the SIPCOT Officer
Fire Approval Charges
Part - J- UG Sump with Pump Room
Earth work open excavation by manual means in all soils and sub-soils and to full depth as may be directed except in rock requiring blasting inclusive of shoring shuttering, bailing out water wherever necessary and depositing the excavated earth with a lead of 10 mts. within the compound in places shown by the SIPCOT Officers and clearing and levelling the site, etc., complete complying with standard specification and as direct-ed by the SIPCOT Officers. Upto 2 m Depth
Upto 2.00m Depth.
2.00m to 3.00 Depth.
ready mixed (Emulsion) of approved quality and colour over one coat priming coat in all floors including the cost of primer etc., complete complying with standard specification and as directed by the SIPCOT Officers.(The make, quality and colour of paint should be got approved by the Executive Engineer before use on works.)
Refilling with excavated earth other than sand with an initial head load of 100 mts. and depositing the earth as shown by the SIPCOT Officers in layers of not more than 15cm thick well rammed with surface vibrator, watered and consolidated etc., complete complying with standard specification and as directed by the SIPCOT Officers.
Cement Concrete 1:3:6 (One Cement, Three crushed stone sand and Six broken stone jelly) using 20mm size hard broken stone jelly for dummy columns,etc., excluding cost of centering shuttering reinforcement grills and fabrication charges but including Cost of Mortar Plasticizer, curing etc. complete and as directed by the SIPCOT Officers. (Dummy columns should be at least 1 metre height)-Mixing by mechanical means
Supplying and erecting steel centering including necessary supports for plane surfaces for Reinforced Cement Concrete works such as column footings, column pedestals, plinth beams, grade beams, staircase steps, Sill slabs etc. which require only nominal strutting using mild steel sheets of size 90cm x 60cm and 10 BG stiffened with welded mild steel angles of size 25mm x 25mm x 3 mm for boarding, laid with silver oak joists of size 10cm x 5cm & 7.5cm x 5cm as support runner , vertical stiffener, side support and Top Horizontal stiffener spaced at about 60cm to 90cm centre to centre or at suitable intervals etc. complete in all floors complying with standard specifcation. (Payment for centering shall be given after the concrete is laid). Below Plinth
Painting new iron works such as steel doors, windows, ventilators, window bars, balustrades etc., with two coats of best approved first quality and colour of synthetic enamel paint over the existing red oxide priming coat in all floors excluding cost of priming coat etc., complete complying with standard specification and as directed by the SIPCOT Officers. (The make, quality and colour of paint should be got approved by the Executive Engineer before use on works.)
Providing and laying in position, Standardised Concrete Mix M-25 Grade by insitu machine mix concrete adopting weighing batch method in accordance with IS:456-2000 using 20mm and down graded hard broken granite stone jelly for all RCC items of works with minimum cement content of 350 kglm3 and maximum water cement ratio of 0.50, including admixture (plasticiser / superplasticiser) in recommended proportions as per IS:9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability with about (5.0 Cu.m) 7730 kg. of 20mm machine crushed stone jelly and with about (3.3 Cu.m) 5156 kg. of 10-12mm machine crushed stone jelly and with about (4.79 cu.m’) 7670 kg. of crushed stone sand, but excluding cost of reinforcement grill and fabricating charges, centering and shuttering and also including laying, vibrating with mechanical vibrators, finishing, curing, etc. and providing fixtures like fan clamps in the RCC floor/ roof slabs wherever necessary without claiming extra, etc., complete complying with standard specification and as directed by the SIPCOT Officers. The coarse and fine aggregates to be used should comply with the requirements of IS Standards. (No separate payment will be made by the Department for the excess usage of materials).
Earth work open excavation by manual means in all soils and sub-soils and to full depth as may be directed except in rock requiring blasting inclusive of shoring shuttering, bailing out water whe
Cement Concrete 1:4:8 (One Cement, four crushed stone sand and Eight hard broken stone jelly) using 40 mm gauge hard broken granite stone jelly for foundation including dewatering wherever necessary and laid in layers of not more than 15 cm thick well rammed, consolidated and including curing etc. complete complying with standard specification and as directed by the SIPCOT Officers -Mixing by mechanical means
rever necessary and depositing the excavated earth with a lead of 10 mts. within the compound in places shown by the SIPCOT Officers and clearing and levelling the site, etc., complete complying with standard specification and as direct-ed by the SIPCOT Officers.
Providing and fixing of safety foot rest of PVC Mould CI steps for sump and having manufacture's permanent identification mark to be visible even after fixing, including fixing in manholes/chambers/sump etc. all complete complying with standard specifications and as directed by "SIPCOT" officers..
Providing and fixing of FRC manhole cover with frame of size 600mmx600mm etc. all complete complying with standard specifications and as directed by "SIPCOT" officers..
Supply, installation 65mm dia GI pipe (Class 'B') 4mtr height with 300mm x 300mm x 6mm base plate with duly welding (MR), MS box of 30cm x 20cm x 10cm with angle iron frame work with lock and key arrangements including Concreting and masonary work for fixing the post all inclusive necessary supports for installation of CCTV camera etc.completion as per the recommended and approved by the SIPCOT Officer
Superstructure in Ground floor
Superstructure in First floor
Supplying and filling in foundation, basement, etc with filling Stone dust/Quarry dust in layers of not more than 15 cm thick well watered, rammed and consolidated etc. complete complying with standard specification and as directed by the SIPCOT Officers.
In Ground floor
In First floor
Supplying and erecting steel centering including necessary supports for plane surfaces for Reinforced Cement K/Concrete works such as vertical slab, side slabs of boxing, vertical drops, facia, vertical wall, etc. using mild steel sheets of size 1200cm x 60cm and 10 BG stiffened with welded mild steel angles of size 40mm x 40mm x5 mm for boarding, laid with silver oak joists of size 10cm x 5cm & 7.5cm x 5cm as support runner, Top Horizontal stiffener spaced at about 60cm to 90cm centre to centre or at suitable intervals. MS Channel Section (ISMC 100) shall be provided as a vertical upport 1.20m C/C and with Lateral support of Steel Adjustable Telescopic Props of Size 2m x 2m (expandable upto 3.60m) & steel pipes of 20mm dia required level/spacing etc. complete complying with standard specifcation and as directed by the SIPCOT Officers. (Payment for centering shall be given after the concrete is laid)
Supplying and erecting centering for plane surfaces such as RCC Floor Slab, Roof Slab, Loft, Landing Slabs, etc with necessary supports and strutting upto 3.60m height in all floors with all cross bracings using MS Sheets made of 10 gauge thick welded with MS angle of Size 25mm x 25mm x 3mm for boarding laid over steel adjustable span of size 2m x 2m (expandable upto 3.60m) and supported by Steel Adjustable Telescopic Props of Size 2m x 2m (expandable upto 3.60m) made with outer steel pipe with dia 50mm (3.60mm thick) and inner steel pipe with dia 40mm (2.90mm thick), etc complete complying with standard specifications. Steel adjustable span and Steel Adjustable telescopic props shall be provided as directed by the SIPCOT Officers. (Payment for centering shall be given after the concrete is laid).
Providing 300mm dia Auger pile to required depth in CC 1:3:6 (one of cement, three of sand, six of hard broken jelly) using 20mm gauge HBG stone jelly excluding cost and fabrication of steel reinforcement grills but including cost of concrete, pouring, Augering, curing, compacting, hire charges for tools and plants etc, complete in all respects and as directed by the SIPCOT Officers
Supplying and erecting steel centering including necessary supports For plane surfaces such as rectangular or square RCC columns etc. which require only nominal strutting using mild steel sheets made of 10 gauge thick welded with MS angle size 40mm x 40mm x 5 mm and supported by Steel Adjustable Telescopic Props of Size 2m x 2m (expandable upto 3.60m) made with outer steel pipe with dia 50mm (3.60mm thick) and inner steel pipe with dia 40mm (2.90mm thick).etc..complete in all floors complying with standard specifcation. Steel Adjustable telescopic props shall be rovided as directed by the SIPCOT Officers. (Payment for centering shall be given after the concrete is laid).
Plain Cement Concrete 1:2:4 (one cement, two crushed stone sand and four hard broken stone jelly) using 20mm jelly for wearing coat including laying, compacting, finishing and curing, etc., complete as per standard specificatins and as directed by the SIPCOT Officers.-Mixing by mechanical means
UPVC WindowSpecification:Supplying and fixing UPVC (Un-Plasticized Polyvinyl Chloride) Windows of casement type (open) from the profile the size of outer frame 60mm x 58mm and shutter profile are reinforcement with GI/1mm 125GSM and 100% corrosion free, the profiles are multi chambered sections with wall thick of 2mm. The EPDM rubber (black colour) covered with over all the edges of frame and shutter the shutter will be provided with Espag multi power point locks and also it operates as handle. The corners and joints should be welded and cleaned. Radiations free pin headed plain or brown colour glass 4mm thick should be provided to the shutter and it should not allow leakage of water even at most ranging storms and should have key lockable action, security protective hinges, strong locking systems and as per size for arresting noise and energy loss. The connecting mechanism between sash and outer frame that enables opening of the window. The window should be fixed to the wall with 100% packing with screws and silicon packing all round the frames. The window should be got approved from the Executive Engineer before use on work
Providing and laying in position, Standardised Concrete Mix M-30 Grade by insitu machine mix concrete adopting weighing batch method in accordance with IS:456-2000 using 20mm and down graded hard broken granite stone jelly for all RCC items of works with minimum cement content of 400 kg/m3 and maximum water cement ratio of 0.45, including admixture (plasticiser / superplasticiser) in recommended proportions as per IS:9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability with about (5.0 Cu.m) 7730 kg. of 20mm machine crushed stone jelly and with about (3.3 Cu.m) 5156 kg. of 10-12mm machine crushed stone jelly and with about (4.79 cu.m’) 7670 kg. of crushed stone sand, but excluding cost of reinforcement grill and fabricating charges, centering and shuttering and also including laying, vibrating with mechanical vibrators, finishing, curing, etc. and providing fixtures like fan clamps in the RCC floor/ roof slabs wherever necessary without claiming extra, etc., complete complying with standard specification and as directed by the SIPCOT Officers. The coarse and fine aggregates to be used should comply with the requirements of IS Standards. (No separate payment will be made by the Department for the excess usage of materials). Foundation and Basement.
Supplying and erecting centering for plane surfaces such as RCC Floor Slab, Roof Slab, Loft, Landing Slabs, etc with necessary supports and strutting upto 3.60m height in all floors with all cross bracings using MS Sheets made of 10 gauge thick welded with MS angle of Size 25mm x 25mm x 3mm for boarding laid over steel adjustable span of size 2m x 2m (expandable upto 3.60m) and supported by Steel Adjustable Telescopic Props of Size 2m x 2m (expandable upto 3.60m) made with outer steel pipe with dia 50mm (3.60mm thick) and inner steel pipe with dia 40mm (2.90mm thick) , etc complete complying with standard specifications. Steel adjustable span and Steel Adjustable telescopic props shall be provided as directed by the SIPCOT Officers. (Payment for centering shall be given after the concrete is laid). Above Plinth
Weathering course in brick jelly lime concrete using broken brick jelly of size 20mm uniform gauge in pure slaked lime (no crushed stone sand to be used) to the proportion of brick jelly to lime being 32:12.5 by volume and laid over the RCC roof slab in a single layer of required slope and finished by beating the concrete with wooden beaters of approved pattern, keeping the surface constantly wet by sprinkling lime jaggery water, etc., complete as per standard specification and as directed by the deparmental officers.
Supplying and erecting steel centering including necessary supports for plane surfaces for Reinforced Cement Concrete works such as vertical slab, side slabs of boxing, vertical drops, facia, vertical wall, etc. using mild steel sheets of size 1200cm x 60cm and 10 BG stiffened with welded mild steel angles of size 40mm x 40mm x 5 mm for boarding, laid with silver oak joists of size 10cm x 5cm & 7.5cm x 5cm as support runner, Top Horizontal stiffener spaced at about 60cm to 90cm centre to centre or at suitable intervals. MS Channel Section (ISMC 100) shall be provided as a vertical upport @1.20m C/C and with Lateral support of Steel Adjustable Telescopic Props of Size 2m x 2m (expandable upto 3.60m) & steel pipes of 20mm dia @ required level/spacing etc. complete complying with standard specifcation and as directed by the SIPCOT Officers. (Payment for centering shall be given after the concrete is laid) Above Plinth
Plastering the surface of walls with Cement Mortar 1:3 (One cement and Three plastering sand), 12mm thick in all floors including mortar plasticizer at 200ml per 50Kg of cement used, curing etc., complete complying with standard specification and as directed by the SIPCOT Officers.
Providing and laying in position, standardised concrete Mix M-20 Grade by insitu machine mix concrete adopting weighing batch method in accordance with IS 456 using 20mm and down graded hard broken granite stone jelly for all RCC items of works with minimum cement content of 325 kg/m3 and maximum water cement ratio of 0.55, including admixture (plasticiser / super plasticiser) in recommended proportions as per IS:9103 to accelerate, retard setting of concrete, improve workability without inspiring strength and durability with about (5 Cu.m) 7730 kg. of 20mm machine crushed stone jelly and with about (3.3 Cu.m) 5156 kg. of 10-12mm machine crushed stone jelly and with about (4.79 cu.m) 7670 kg. of crushed stone sand, but excluding cost ofreinforcement grill and fabricating charges, centering and shuttering and also including laying,vibrating with mechanical vibrators, finishing, curing, etc. and providing fixtures like fan clamps in the RCC floor/ roof slabs wherever necessary without claiming extra, etc.,complete complying with standard specification and as directed by the SIPCOT Officers. The coarse and fine aggregates to be used should comply with the requirements of IS standards. (No separate payment will be made by the Department for the excess usage of materials). Foundation and Basement.
Supplying and laying of Interlocking Paver Block Stone 63mm thick Over a 80mm tk base layer of crushed stone sand filling incl. Cost of materials laying and Labour charges etc complete complying with the standard specification and as directed by the SIPCOT Officers.
Earth work excavation for foundation by manual means for Isolated, Combined and Other type foundations in all soils and sub-soils and to full depth as may be directed except in rock requiring blasting inclusive of shoring shuttering, bailing out water wherever necessary and depositing the surplus earth within the compound in places shown by the SIPCOT Officers with an initial lead of 10 mts and initial lift of 2.00mts. and clearing and levelling the site, etc., complete complying with standard specification and as directed by
Supplying and Erecting Pull and Push Type Rolling Shutter with ISI make of approved size and section using 18 GI sheet. The shutter shall be painted with one coat of red oxide primer and the rate is inclusive of hood covers, transportation charges etcGear Operated Type (from 8 sqm. to 12 sqm. Area)
Providing granolithic floor finish of 25mm thickness with plain cement concrete 1:2:4 (One Cement, Two Crushed Stone Sand and Four aggregate) using 6 to12mm gauge hard broken stone jelly including laying, finishing and the top rubbed smooth with power trowel, thread lining, curing etc. complete complying with standard specification and as directed by the SIPCOT Officers. (The rate is inclusive of necessary planking for panelling wherever necessary and as directed by the SIPCOT Officers)
110mm dia PVC Pipe for Two Floors
Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer etc. all complete complying with standard specifications and as directed by "SIPCOT" officers..
Part - K - Pump Room Internal Electrical
supply and fixing of 450mm sweep heavy duty AC exhaust fan complete with louvers shutters arrangements etc complete as directed and approved by SIPCOT Officers
Supply, installation, testing & Commissioning of Plate Earthing as per PWD standard with a copper earth plate of size 600X600X3mm with necessary funnelling arrangements and masonry works and 38mm RCC Cover slab for brick masonry etc. complete and as directed by SIPCOT Officers.
4 Core X 10 Sq.mm. AR.Al.UG. Cable.
Supply and run of 50mm x 6mm copper Flat Down Conductor with necessary clamps / supports on wall / floor / ground for earth connection etc. complete and as directed by SIPCOT Officers.
4core x 10 sq.mm. Ar. Al. UG cable
Supply of 2m x 1m Rubber Mat suitable for 11 KV installation confirming to IS etc. complete and as directed by SIPCOT Officers.
3core x 16 sq.mm. Ar. Al. UG cable
supply and fixing of 1200mm (48") sweep AC ceiling fan 5 star rated complete with 2 module fan step regulator with 1 metre down rod with fan clamp with side plates and cross arm etc complete as directed and approved by SIPCOT Officers
Supply and fixing of 60W LED street light fitting with LED (Lower end) with 32mm dia. GI pipe (class B) with 1 no.32 mm dia GI bend complete on the existing post/ on wall with PVC unsheathed FRLS copper leads with MS clamps and with painting etc complete as directed and approved by SIPCOT Officers
11kV 2pole Structures: Supply, installation, & commissioning of Providing 11kV Double Pole Structure with AB Switch 12kV, 630A, 26.3kA for 3sec, 3-ph, 3 Pin type, Vertical/ Horizental Mounting type, Gang Operated, AB Switch along with Support Insulators, Base Channel down Pipe, Arcing Horns etc. complete as per technical specifications, scope of works and approved drawings on Poles as per technical specification, approved drawings and scope of work. etc,...complete as directed and approved by SIPCOT Officers.
Supply of First Aid Box complete with all First Aid Medicines etc. complete and as directed by SIPCOT Officers.
HT Metering Sets with METERING BOX:Supply, installation, testing & commissioning HT Metering Sets with 11KV metering cubicles 11 KV set , 10/5A., accuracy 0.2 S covers design, fabrication, manufacture, painting, testing of 11KV metering cubicles for HT consumers with 0.2S class 11 KV CTs & PTs bushings, connecting bus bars, control cables duly terminated suitable for supply energy measurement system and for indoor as well as outdoor application etc. complete as directed and approved by SIPCOT Officers.
Supplying and making outdoor cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for size of 300 sq.mm. 3 core HT Cable Outdoor Terminations XLPE 11KV (E) etc. complete as directed and approved by SIPCOT Officers.
Supply of Shock Treatment Chart fixed in glass frame etc. complete and as directed by SIPCOT Officers.
Supply of 4 Nos. Fire Buckets made out of 40 x 40 x 6mm MS Angle etc. complete and as directed by SIPCOT Officers.
Supply of rubber Hand Gloves of 11KV Grade etc. complete and as directed by SIPCOT Officers.
Manufacturing supplying and fixing of Fully Panelled steel door with the following specification MS angels of size 40x40x6mm are used for the outer frames and M.S. angle
Supply, erection, testing and commissioning of following MS ‘C’ Class Heavy Duty Pipe as per IS 1239 to withstand a developing pressure of 10 kg. / sq.cm including necessary fittings like MS flange of table ‘E’, elbows, reducers, gaskets, bolt, nuts with washers & joints as per standard method of arc welding, including one coat metal primer and two coat Post Office Red painting including conveyance, all incidental charges, neccessary scaffolding and re-doing the dismantled portions to its original condition wherever found neccessary, etc., complete as per standard specification and as directed by the SIPCOT Officers. (Above Ground)
Supply, erection, testing and commissioning of cast iron body
Supplying, Fabricating and placing in position steel reinforcement grills using M.S. I R.T.S. rods of all sizes of reinforcement for all Reinforced cement: concrete works (for pedestal pillar concrete) including cost and conveyance of stee
s of size 35x35x5mm for the shutter frames, stiffeners with 32 x 6mm M.S flat is provided at required intervals in the shutter frame. 18-gauge C.R. sheet laid as panel in the shutter and welded intact. M.S. flat 18x5mm is welded over the 32 x 6mm M.S. flat sandwitching the C.R. sheet in between additional stiffeners with 18x5mm M.S. flat is provided diagonally at the rear side of the shutter. 3nos. of Steel Parliament Hinges of Size 125mm x 150mm in case of single leaf and 6nos. of Steel Parliament Hinges of Size 125mm x 150mm in double leaves shutter to be provided. 6nos. of holdfasts 200 mm in length made of angle section spliced at the ends are welded to the outer frames of the door. Tower bolts 3 nos, one at the top, one at lock rail(Inner) and the other at the bottom are provided 1no. Aldrop is provided at lock rail section in the door 2 Nos of 200mm handle are to be provided. One rotaing locking arrangements for the inner side of the door and additional provision for locking arrangements for lock is provided on the rear side of the door at an appropriate place. Incase of double leaf door M.S.Flat 32 x 3mm at 1.1Kg/m is provided on the one shutter t conceal the gap between the two shutters. at an appropriate place in the door. A tie bar is provided at the bottom of the frame to prevent twisting of frame during transportation and fixing. All members are given a coat of red oxide primer as directed by the SIPCOT Officers. The rate includes cost of all materials, labour charges, transportation to site of work, loading, un loading and all other incidental charges etc., complete complying with standard specification and as directed by the SIPCOT Officers. -Single leaf of size 1.00m x 2.10m.
Plastering the surface of walls with Cement Mortar 1:3 (One cement and Three plastering sand), 12mm thick in all floors including mortar plasticizer at 200ml per 50Kg of cement used, curing etc., complete complying with standard specification and as directed by the SIPCOT Officers.
and bronze internal non-rising spindle sluice valve of sizes at required places to control the flow of water including necessary MS flange of table ‘E’, gaskets, bolts & nuts including conveyance, all incidental charges, neccessary scaffolding and re-doing the dismantled portions to its original condition wherever found neccessary, etc., complete as per standard specification and as directed by the SIPCOT Officers.
Supplying and fixing Mild Steel grills for windows, ventilators etc.,complete complying with standard specifications and as directed by the SIPCOT Officers.
Providing granolithic floor finish of 52mm thickness with plain cement concrete 1:2:4 (One Cement, Two Crushed Stone Sand and Four aggregate) using 6 to12mm gauge hard broken stone jelly including laying, finishing and the top rubbed smooth with power trowel, thread lining, curing etc. complete complying with standard specification and as directed by the SIPCOT Officers. (The rate is inclusive of necessary planking for panelling wherever necessary and as directed by the SIPCOT Officers)
Creche, canteen and Medical Facility Building
Part - L - Admin Building Water Tank
Admin Building
Supply of HT Rubber Mat installation size of 2m x 1m confirming to IS etc. complete and as directed by SIPCOT Officers.
Supply and run of 2of No.8 SWG GI. wire for earth connection with necessary clamps / supports on wall / floor / ground for earth connection etc. complete and as directed by SIPCOT Officers.
Supply and fixing of 12 way single pole and neutral MCB sheet steel enclosure distribution board with double door (metal) with 1 no. 32A DP MCB switch as incoming and 10 nos. 6A to 32A SP MCB as outgoing in flush with wall with earth connection only complete etc.complete as directed and approved by SIPCOT Officers.
Supply and laying of GI Hot Dip / Powder Coated 16 SWG Cable Tray with 300mm width and 50mm height Ladder type cable tray etc.complete as directed and approved by SIPCOT Officers.
Supply and fixing of 60W LED street light fitting with LED with 32mm dia. GI pipe (class B) with 1 no.32 mm GI bend complete on the existing post/ on wall with PVC unsheathed copper leads with MS clamps and with painting etc.complete as directed and approved by SIPCOT Officers.
Supply and laying of RCC Hume Pipe size of 300mm dia which include the earth excavation, refilling the earth etc.complete as directed and approved by SIPCOT Officers.
Supply, laying, commissioning and testing of CAT 6A UTP Unarmoured Cable through 25mm PVC conduit .or as per the approval of site engineer incharge. painting of suitable colour etc.complete as directed and approved by SIPCOT Officers.
Part - N - External Power Distribution.
Supply and Laying of 6 Core Out door OFC cable in suitable size HDPE pipe in a trench to be excavated at a depth of 0.75 metre and refilling the earth to make good. etc.complete as directed and approved by SIPCOT Officers.
Brick work in Cement Mortar 1:5 using best quality Burnt Clay Brick of size 9” x 4 1/2” x 3” with class designation of 7.5 conforming to IS 1077-1992 for oundation and basement including Cost of Mortar Plasticizer curing, etc.,complete complying with standard specification and as directed by the SIPCOT Officers. Brickwork shall be done as per IS 2212-1991 adopting English Bond generally.other type of bond shall be done as directed by the SIPCOT OfficersFoundation and Basement.
The LT Panel shall be indoor, floor-mounted, dust and vermin proof, fabricated from 2.0 mm CRCA sheet steel with seven-tank process powder coating, modular in construction, and conforming to IP-54 as per IS/IEC 60529. It shall operate on 415 V, 3 Phase, 4 Wire, 50 Hz AC system with a rated capacity of 400 A. The panel shall be totally enclosed, compartmentalized, and mounted on a rigid MS angle/ISMC base frame with hinged lockable doors, neoprene gaskets, and adequate ventilation.The High-conductivity electrolytic copper busbars, 400 A rated, PVC sleeved, and color-coded, with short-circuit withstand capacity as per IS 8623/IEC 61439, shall be provided. Incoming feeders shall comprise 2 Nos. 400 A, 4 Pole MCCBs (EB & DG) and 1 No. 125 A, 4 Pole MCCB (Solar), all with thermal-magnetic/microprocessor release, rotary handle, and complete cable entry arrangements with glands/lugs.Outgoing of following250 A, 4P MCCB - 2Nos125 A, 4P MCCB - 1No63-100 A, 4P MCCB - 10nosThe panel shall include a digital multifunction meter, RYB indicating lamps with control MCBs, earth leakage protection, CTs of suitable ratio and class, space heaters with thermostat and switch, and earthing studs on both sides individual digital multifunctional meter with RS485 port and suitable CT etc. including concrete pedestal and associated civil works etc. complete and as directed by engineer in-charge.
3.5 core x 300 sq.mm. Ar. Alu. UG cable
3.5 core x 35 sq.mm. Ar. Alu. UG cable
Supplying, fabricating and placing in position Mild Steel / Ribbed Tor Steel reinforcement grills of all variety like HYSD/CTD/TMTand all grade like Fe 500, Fe550D, Fe 500 D etc., for all RCC works as per design given including cost of steel reinforcement and G.I. binding wire, wastage etc. complete complying with standard specification and as directed by the SIPCOT Officers.(Contractor has to make his own arrangements for the supply of steel reinforcement and binding wire) Upto Plinth / Basment Level.
The LT Panel shall be indoor, floor-mounted, dust and vermin proof, fabricated from 2.0 mm CRCA sheet steel with seven-tank process powder coating, modular in construction, and conforming to IP-54 as per IS/IEC 60529. It shall operate on 415 V, 3 Phase, 4 Wire, 50 Hz AC system with a rated capacity of 400 A. The panel shall be totally enclosed, compartmentalized, and mounted on a rigid MS angle/ISMC base frame with hinged lockable doors, neoprene gaskets, and adequate ventilation.The High-conductivity electrolytic copper busbars, 400 A rated, PVC sleeved, and color-coded, with short-circuit withstand capacity as per IS 8623/IEC 61439, shall be provided. Incoming feeders shall comprise 2 Nos. 400 A, 4 Pole MCCBs (EB & DG) and 1 No. 125 A, 4 Pole MCCB (Solar), all with thermal-magnetic/microprocessor release, rotary handle, and complete cable entry arrangements with glands/lugs.Outgoing of following250 A, 4P MCCB - 2Nos125 A, 4P MCCB - 1No63-100 A, 4P MCCB - 10nosThe panel shall include a digital multifunction meter, RYB indicating lamps with control MCBs, earth leakage protection, CTs of suitable ratio and class, space heaters with thermostat and switch, and earthing studs on both sides individual digital multifunctional meter with RS485 port and suitable CT etc. including concrete pedestal and associated civil works etc. complete and as directed by engineer in-charge.
3.5 core x 300 sq.mm. Ar. Alu. UG cable
3.5 core x 35 sq.mm. Ar. Alu. UG cable
Supply and laying of the following size of PVC armoured LTUG cable in a trench to be excavated at a depth of 0.75 metre putting 0.15 metre layer of sand and covering the three sides of the cable and refilling the earth to make good etc., complete and as directed by SIPCOT SIPCOT Officers.
The LT Panel shall be indoor, floor-mounted, dust and vermin proof, fabricated from 2.0 mm CRCA sheet steel with seven-tank process powder coating, modular in construction, and conforming to IP-54 as per IS/IEC 60529. It shall operate on 415 V, 3 Phase, 4 Wire, 50 Hz AC system with a rated capacity of 400 A. The panel shall be totally enclosed, compartmentalized, and mounted on a rigid MS angle/ISMC base frame with hinged lockable doors, neoprene gaskets, and adequate ventilation.The High-conductivity electrolytic copper busbars, 400 A rated, PVC sleeved, and color-coded, with short-circuit withstand capacity as per IS 8623/IEC 61439, shall be provided. Incoming feeders shall comprise 2 Nos. 400 A, 4 Pole MCCBs (EB & DG) and 1 No. 125 A, 4 Pole MCCB (Solar), all with thermal-magnetic/microprocessor release, rotary handle, and complete cable entry arrangements with glands/lugs.Outgoing of following250 A, 4P MCCB - 2Nos125 A, 4P MCCB - 1No63-100 A, 4P MCCB - 10nosThe panel shall include a digital multifunction meter, RYB indicating lamps with control MCBs, earth leakage protection, CTs of suitable ratio and class, space heaters with thermostat and switch, and earthing studs on both sides individual digital multifunctional meter with RS485 port and suitable CT etc. including concrete pedestal and associated civil works etc. complete and as directed by engineer in-charge.
3.5 core x 300 sq.mm. Ar. Alu. UG cable
3.5 core x 35 sq.mm. Ar. Alu. UG cable
SPNDB: Supply and fixing of 8 way single pole and neutral MCB sheet steel enclosure distribution board with double door (metal) with 1 no. 32A DP MCB as incoming and 6 nos. 6A to 32A SP MCB as outgoing on suitable on wall with earth etc. Complete as directed and approved by SIPCOT Officers.
Supply of Fire Extinguisher Co2, 4.5 kg. confirming to TAC Norms etc. complete and as directed by SIPCOT Officers.
Light and fan point wiring Wiring with 2 x1.5 sq.mm. PVC insulated single core unsheathed FRLSH copper conductor of 1100 V grade in suitable PVC rigid pipe Concealed in wall and open as required and ceiling with PVC accessories, ceiling rose and round sheet with flexible hose, Module Gl switch box in flush with wall with 6A one way module switch with module front plate with continuous earth wire connection of 1.5 sq.mm copper wire and making good of the concealed portion with suitable colour for Concealed PVC Light point/fan point etc. Complete as directed and approved by SIPCOT Officers.
Supply and fixing of brass cable gland for following PVC LTUG aluminium armoured cable with earth connection etc.for following sizes of cables etc., complete and as directed by SIPCOT SIPCOT Officers.
Supply of Earth Discharge Rod etc. complete and as directed by SIPCOT Officers.
termination of following size PVC LTUG aluminium armoured cable with necessary aluminium cable sockets by crimping etc with electrical connection complete etc., complete and as directed by SIPCOT SIPCOT Officers.
Supply, installation,9U Rack- RACK WITH ACCESSORIES inter connecting wiring including PDU and other accessories all inclusive etc. complete and as directed by SIPCOT SIPCOT Officers.
Supply of HT Rubber hand gloves as per the norms etc. complete and as directed by SIPCOT Officers.
3.5 core x 185 sq.mm. Ar. Alu. UG cable
Part - O - External Street Light
Design, manufacture, supply, erection, testing and commissioning of 415 V streetlight service feeder pillar panel 1200mm x 900mm x 300mm suitable for outdoor installation, made up of CRCA sheet steel of thickness not less than 2 mm with a weather proof canopy of top, double door construction, IP 55 protection, with 2 coat of primer and 2 coats of aluminium finish with 1no. 100A A TPN MCCB with 25 kA breaking capacity in the incoming and 6nos 32 A, TPN contactor 6nos. 32A TPN MCB, 9nos, of 6-32A SP MCB as outgoing, automatic dawn and dusk with cyclic timer control for street light outgoing and adequate plate to terminate suitable cable as incomer and suitable cable as outgoing. energy saver for automatic switching ON/OFF as per pre-sets time cycle, digital multifunctional meter with RS485 port and suitable CT etc. including the pillar to be erected with suitable angle iron frame pedestal with concrete grouting etc., complete and as directed by officers.
Supplying and erection of 8m Free Standing Double Arm Bracket 8 sided Octagonally continuously tapered structured pole galvanized iron coated (GI) with minimum coating of not less than 65-75 micron, with 130mm bottom A/F & 70mm at top A/F made up of 3mm thick HT sheet along with base plate of size 300 x 300 x 12mm thick including 4 Nos of M24X750mm high "J" type EN8 grade foundation bolts along with template and 1.5mtr long hot dip galvanized Single / double arm bracket made up of 40NB dia GI pipe suitable to mount on pole having top of 70mm A/F and including Bakelite sheet with 1 No 6A SP MCB and stud type connector suitable for 4CX25Sqmm cable etc., complete complying with standard specifications and as directed by SIPCOT officers.
Supplying and erection of 6m Free Standing single Arm Bracket Single Bracket Pole with Base Plate Octagonally continuously tapered structured pole galvanized iron coated (GI) with minimum coating of not less than 65-75 micron, with 130mm bottom A/F & 70mm at top A/F made up of 3mm thick HT sheet along with base plate of size 250x250x12mm thick including 4 Nos of M24X750mm high "J" type EN8 grade foundation bolts along with template and 1.5mtr long hot dip galvanized Single / double arm bracket made up of 40NB dia GI pipe suitable to mount on pole having top of 70mm A/F and including Bakelite sheet with 1 No 6A SP MCB and stud type connector suitable for 4CX25Sqmm cable etc., complete complying with standard specifications and as directed by SIPCOT officers.
Design, manufacture, testing and inspection at places of manufacturer, and supplying, delivery at site, unloading, storing, transporting directly to site or through transit stores as the case may be, installation, final painting, testing and commissioning of street lighting fixtures suitable for 80 W LED street light fitting with cool day light, made out of pressure die cast aluminium body, separate compartment for LED, including electronic drivers, day light colour LED lamps, inter connecting wiring with suitable fixing clams as required including accessories all inclusive etc., complete complying with standard specifications and as directed by SIPCOT officers.
Design, manufacture, testing and inspection at places of manufacturer, and supplying, delivery at site, unloading, storing, transporting directly to site or through transit stores as the case may be, installation, final painting, testing and commissioning of street lighting fixtures suitable for 120W LED street light fitting with cool day light, made out of pressure die cast aluminium body, separate compartment for LED, including electronic drivers, day light colour LED lamps, inter connecting wiring with suitable fixing clams as required including accessories all inclusive etc., complete complying with standard specifications and as directed by SIPCOT officers.
Providing and laying in position, Standardised Concrete Mix M-25 Grade by insitu machine mix concrete adopting weighing batch method in accordance with IS:456-2000 using 20mm and down graded hard broken granite stone jelly for all RCC items of works with minimum cement content of 350 kglm3 and maximum water cement ratio of 0.50, including admixture (plasticiser / superplasticiser) in recommended proportions as per IS:9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability with about (5.0 Cu.m) 7730 kg. of 20mm machine crushed stone jelly and with about (3.3 Cu.m) 5156 kg. of 10-12mm machine crushed stone jelly and with about (4.79 cu.m’) 7670 kg. of crushed stone sand, but excluding cost of reinforcement grill and fabricating charges, centering and shuttering and also including laying, vibrating with mechanical vibrators, finishing, curing, etc. and providing fixtures like fan clamps in the RCC floor/ roof slabs wherever necessary without claiming extra, etc., complete complying with standard specification and as directed by the SIPCOT Officers. The coarse and fine aggregates to be used should comply with the requirements of IS Standards. (No separate payment will be made by the Department for the excess usage of materials). Foundation and Basment.
Supply and fixing of 65 mm dia.GI pipe of 6 metre length with 300mm x 300mm x 6mm MS base plate duly welded at the bottom with concreting with construction of masonary pedestal with suitable SMC box with door arrangement to house 6A SP MCB switch, 2/4 way connector on suitable hylem sheet and supply and fixing of 60W LED street light fitting with LED (Lower end) with 1 metre 32mm dia. GI pipe (class B) Complete with suitable MS clamps for LED street light fitting and SMC box with PVC unsheathed FRLS copper leads from SMC box to fitting and with painting of suitable colour .
4core x 16 sq.mm. Ar. Alu. UG cable ( For street light pole )
Brick work in In Cement Mortar 1:5 using best quality II Class Ground Moulded Chamber Burnt Bricks of size - 9" x 41/2" x 3" with Class Designation of 7.5 conforming to IS 1077-1992 for foundation and basement including Cost of Mortar Plasticizer curing, etc.,complete complying with standard specification and as directed by the SIPCOT Officers. Brickwork shall be done as per IS 2212-1991 adopting English Bond generally.other type of bond shall be done as directed by the SIPCOT OfficersFoundation and Basment.
Supply and fixing of 65 mm dia.GI pipe of 6 metre length with 300mm x 300mm x 6mm MS base plate duly welded at the bottom with concreting with construction of masonary pedestal with suitable SMC box with door arrangement to house 6A SP MCB switch, 2/4 way connector on suitable hylem sheet and supply and fixing of 60W LED street light fitting with LED (Lower end) with 1 metre 32mm dia. GI pipe (class B) Complete with suitable MS clamps for LED street light fitting and SMC box with PVC unsheathed FRLS copper leads from SMC box to fitting and with painting of suitable colour .
4core x 16 sq.mm. Ar. Alu. UG cable ( For street light pole )
Cement Concrete 1:3:6 (One Cement, Three crushed stone sand and Six broken stone jelly) using 40mm size hard broken stone jelly excluding cost of centering shuttering reinforcement grills and fabrication charges but including curing etc
Supply and fixing of 65 mm dia.GI pipe of 6 metre length with 300mm x 300mm x 6mm MS base plate duly welded at the bottom with concreting with construction of masonary pedestal with suitable SMC box with door arrangement to house 6A SP MCB switch, 2/4 way connector on suitable hylem sheet and supply and fixing of 60W LED street light fitting with LED (Lower end) with 1 metre 32mm dia. GI pipe (class B) Complete with suitable MS clamps for LED street light fitting and SMC box with PVC unsheathed FRLS copper leads from SMC box to fitting and with painting of suitable colour .
4core x 16 sq.mm. Ar. Alu. UG cable ( For street light pole )
. complete and as directed by the SIPCOT Officers. - Mixing by mechanical means
Brick work in Cement Mortar 1:5 using best quality Burnt Clay Brick of size 9” x 4 1/2” x 3” with class designation of 7.5 conforming to IS 1077-1992 for oundation and basement including Cost of Mortar Plasticizer curing, etc.,complete complying with standard specification and as directed by the SIPCOT Officers. Brickwork shall be done as per IS 2212-1991 adopting English Bond generally.other type of bond shall be done as directed by the SIPCOT Officers Foundation and Basement.
Providing and laying in position, Standardised Concrete Mix M-25 Grade by insitu machine mix concrete adopting weighing batch method in accordance with IS:456-2000 using 20mm and down graded hard broken granite stone jelly for all RCC items of works with minimum cement content of 350 kglm3 and maximum water cement ratio of 0.50, including admixture (plasticiser / superplasticiser) in recommended proportions as per IS:9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability with about (5.0 Cu.m) 7730 kg. of 20mm machine crushed stone jelly and with about (3.3 Cu.m) 5156 kg. of 10-12mm machine crushed stone jelly and with about (4.79 cu.m’) 7670 kg. of crushed stone sand, but excluding cost of reinforcement grill and fabricating charges, centering and shuttering and also including laying, vibrating with mechanical vibrators, finishing, curing, etc. and providing fixtures like fan clamps in the RCC floor/ roof slabs wherever necessary without claiming extra, etc., complete complying with standard specification and as directed by the SIPCOT Officers. The coarse and fine aggregates to be used should comply with the requirements of IS Standards. (No separate payment will be made by the Department for the excess usage of materials). Foundation and Basement.
Providing 52mm thick granolithic floor finish of the following thickness with plain cement concrete 1:2:4 (One Cement, Two Crushed Stone Sand and Four aggregate) using 6 to12mm gauge hard broken stone jelly including laying, finishing and the top rubbed smooth with power trowel, thread lining, curing etc. complete complying with standard specification and as directed by the SIPCOT Officers. (The rate is inclusive of necessary planking for panelling wherever necessary and as directed by the SIPCOT Officers)
Supplying, fabricating and placing in position Mild Steel / Ribbed Tor Steel reinforcement grills of all variety like HYSD/CTD/TMTand all grade like Fe 500, Fe550D, Fe 500 D etc., for all RCC works as per design given including cost of steel reinforcement and G.I. binding wire, wastage etc. complete complying with standard specification and as directed by the SIPCOT Officers.(Contractor has to make his own arrangements for the supply of steel reinforcement and binding wire) Upto Plinth / Basement.
3.5core x 50 sq.mm. Ar. Alu. UG cable ( I/C to Feeder pillar box )
Supplying and erecting centering for sides and soffits including necessary supports and strutting up to 3.29 M height for plane surfaces as detailed below in all floors with all cross bracings using Mild Steel sheets of size 90 x 60 cm and 10 BG stiffened with welded Mild Steel angle of size 25mm x 25mm x 3 mm for boarding laid over silver oak joists of size 10cm x 6.50 cm spaced at abote 90 cm centre to centre and supported by casurina props of 10cm to 13 cm dia spaced at not more than 75 cm centre to centre etc., complete complying with the standard specificaiton and as directed by SIPCOT officers. (Payment for centering shall be given after the concrete is laid)
Plastering with Cement Mortar 1:5 (One cement and Five Plastering sand), 12mm thick in all floors including mortar plasticizer at 200ml per 50Kg of cement used, curing etc. complete complying with standard specification and as directed by the SIPCOT Officers
Earth work excavation for foundation by manual means for Isolated, Combined and Other type foundations in all soils and sub-soils and to full depth as may be directed except in rock requiring blasting inclusive of shoring shuttering, bailing out water wherever necessary and depositing the surplus earth within the compound in places shown by the SIPCOT Officers with an initial lead of 10 mts and initial lift of 2.00mts. and clearing and levelling the site, etc., complete complying with standard specification and as directed by
the SIPCOT Officers.
Supplying and erecting steel centering including necessary supports for plane surfaces for Reinforced Cement 50 Concrete works such as column footings, column pedestals, plinth beams, grade beams, staircase steps, Sal slabs etc. which require only nominal strutting using mild steel sheets of size 90cm x 60cm and 10 BG stiffened with welded mild steel angles of size 25mm x 25mm x 3 mm for boarding, laid with silver oak joists of size 10cm x 5cm & 7.5cm x 5cm as support runner vertical stiffener, side support and Top Horizontal stiffener spaced at about 60cm to 90cm centre to centre or at suitable intervals etc. complete in all floors complying with standard specifcation. (Payment for centering shall be given after the concrete is laid).
Cement Concrete 1:4:8 (One Cement, four crushed stone sand and Eight hard broken stone jelly) using 40 mm gauge hard broken granite stone jelly for foundation including dewatering wherever necessary and laid in layers of not more than 15 cm thick well rammed, consolidated and including curing etc. complete complying with standard specification and as directed by the SIPCOT Officers -Mixing by mechanical means
Manufacturing, supplying and fixing in position Reinforced Cement concrete perforated precast slab of 100 mm thick in Cement Concrete M25 grade including cost of moulding charges, casting of slab, finishing, curing, placing etc. all complete complying with standard specifications and as directed by "SIPCOT" officers..( At pedestrian crossing)
Supply of approved make 8TB HDD as per the recommended and approved by the SIPCOT Officer
Supply, installation, testing, commissioning of approved make 8 Port POE Switch as per the recommended and approved by the SIPCOT Officer
the SIPCOT Officers.
Supplying and erecting steel centering including necessary supports for plane surfaces for Reinforced Cement 50 Concrete works such as column footings, column pedestals, plinth beams, grade beams, staircase steps, Sal slabs etc. which require only nominal strutting using mild steel sheets of size 90cm x 60cm and 10 BG stiffened with welded mild steel angles of size 25mm x 25mm x 3 mm for boarding, laid with silver oak joists of size 10cm x 5cm & 7.5cm x 5cm as support runner vertical stiffener, side support and Top Horizontal stiffener spaced at about 60cm to 90cm centre to centre or at suitable intervals etc. complete in all floors complying with standard specifcation. (Payment for centering shall be given after the concrete is laid).
Change over switch:Supply and fixing of 250 Amps Three Phase 4 Pole Change Over Switch on suitable angle iron frame work with MS cable entry boxes for incoming and outgoing earthing etc.complete as directed and approved by SIPCOT Officers.
Cement Concrete 1:4:8 (One Cement, four crushed stone sand and Eight hard broken stone jelly) using 40 mm gauge hard broken granite stone jelly for foundation including dewatering wherever necessary and laid in layers of not more than 15 cm thick well rammed, consolidated and including curing etc. complete complying with standard specification and as directed by the SIPCOT Officers -Mixing by mechanical means
Providing and laying in position, standardised concrete Mix M-20 Grade by insitu machine mix concrete adopting weighing batch method in accordance with IS 456 using 20mm and down graded hard broken granite stone jelly for all RCC items of works with minimum cement content of 325 kg/m3 and maximum water cement ratio of 0.55, including admixture (plasticiser / super plasticiser) in recommended proportions as per IS:9103 to accelerate, retard setting of concrete, improve workability without inspiring strength and durability with about (5 Cu.m) 7730 kg. of 20mm machine crushed stone jelly and with about (3.3 Cu.m) 5156 kg. of 10-12mm machine crushed stone jelly and with about (4.79 cu.m) 7670 kg. of crushed stone sand, but excluding cost ofreinforcement grill and fabricating charges, centering and shuttering and also including laying,vibrating with mechanical vibrators, finishing, curing, etc. and providing fixtures like fan clamps in the RCC floor/ roof slabs wherever necessary without claiming extra, etc.,complete complying with standard specification and as directed by the SIPCOT Officers. The coarse and fine aggregates to be used should comply with the requirements of IS standards. (No separate payment will be made by the Department for the excess usage of materials). Foundation and Basement.
Finishing the top of roof using Pressed Tiles of 230mm x 230mm x 16 mm to 18mm of approved quality set in Cement Mortar 1:3 (One Cement and Three Crushed stone Sand) 12mm thick mixed with water proofing compound conforming to ISS at 2% by weight of cement used and the joints pointed neatly to full depth of tiles with the same cement mortar mixed with red oxide and water proofing compound including curing etc., complete complying with standard specification and as directed by the SIPCOT Officers
Special ceiling plastering and finishing the exposed surface of all RCC items of work such as slabs, beams, sunshades, facia, canopy slab, staircase waist slab, landing slab etc., with Cement Mortar 1:3 (One Cement and Three Plastering Sand) 10mm thick including mortar plasticizer at 200ml per 50Kg of cement used , hacking the surfaces and curing, etc., in all floors complying with standard specification and as directed by the SIPCOT Officers
Manufacturing, supplying and fixing in position plain cement concrete precast kerb stone Size of 600 x 325 x 165mm and Design in Cement Concrete 1:3:6 (One cement, three sand and six jelly) using 20mm HBG stone jelly including cost of moulding charges, casting of slab, finishing, curing, fixing and pointing the slab with CM 1:3 (One Cement and Three Sand) to full depth of kerb and the shape of kerb stone as per drawing, the cost including manufacturing, transportation, laying in position, curing etc., complete complying with standard specification
Supplying, fabricating and placing in position Mild Steel / Ribbed Tor Steel reinforcement grills of all variety like HYSD/CTD/TMTand all grade like Fe 500, Fe550D, Fe 500 D etc., for all RCC works as per design given including cost of steel reinforcement and G.I. binding wire, wastage etc. complete complying with standard specification and as directed by the SIPCOT Officers.(Contractor has to make his own arrangements for the supply of steel reinforcement and binding wire)
Construction of Granular Sub - Base (GSB) to the required compacted thickness (Drainage layer) by providing approved Coarse graded material conforming to Grading-V of Table 400 - 1 and satisfying the physical requirement for material for GSB as per Table 400 - 2 of MORTH Rev -5 including screening, spreading in uniform layers with motor grader on prepared surface, watering and premixing by mix in place method with rotavator at OMC, and compacting with Vibratory roller 80 to 100 KN static weight to achieve the desired density and fine dressing to required grade and cross slope as directed by the SIPCOT officers etc., complete including obtaining and transporting all materials from approved quarry site to work site with all lift and lead by mechanical transport, head load or any other mode of transporation including cost and conveyance of all materials, labour charges,hire charges and fuel charges for loader, water tanker with sprinkler,motor grader, vibratory road rollers and all other equipments, tools and plants, safety measures, testing required including all other incidental charges, etc., complete as per the standard specification as per clause 401 of MORTH Rev.-5 and as directed by the SIPCOT officers.
Providing, laying, spreading and compacting graded stone aggregates for Wet Mix Macadam 250mm thick, including premixing the materials with water at OMC in mechnanical mix plant, conveyance of mixed materials by tipper to site, laying in uniform layers using pavers in Sub Base/ Base course on well prepared surface and compacting with vibratory roller to acheive the desired density including cost of material, labour charges, rentals for machinery, fuel and all other incidental charges etc., complete as per clause 406 of MORTH Rev-5
Part - P - Storm Water Drain
Part - R - Paver Finish in Driveway, Footpath.
Providing, laying 50mm consolidated thick Dense Bituminous Macadam using 0.24cum of 26.50- 13.20mm, 0.25cum of 13.20-2.36mm and 0.23cum of 2.36mm & below and with 53.20Kgs of VG30 Grade bitumen for premixing per 10sqm including cost and conveyance of all materials to CMP site, heating the bitumen, aggregate and mixing them in the required temperature in Central Hot Mix Plant 20- 30 ton capacity, conveying the mix by tipper trucks to work site, spreading the mix to uniform thickness of 50mm using paver to the specified grades and cross sections and compacted by Vibratory / Pneumatic Roller to the required density etc., including labour for attending to paver at site etc., including hire and fuel charges for 20-30ton CMP with bitumen boiler, tipper trucks, Paver Finisher, Vibratory rollers and all other tools and plant required, including all other incidental charges etc., complete as per specification using CMP as per clause 505 MORTH Rev-5
Providing and laying Bituminous Concrete to 30/40mm thick using 0.13 cum of 19.00- 9.50mm, 0.17 cum of 9.50-2.36mm and 0.26 cum of 2.36 and below with 50.30kgs of VG30 bitumen for premixing per 10sqm including cost and conveyance of all materials to CMP site, heating the bitumen and aggregate to required temperature and mixing them in required temperature in central hot mix plant 20-30 ton capacity, conveying the mix by tipper trucks to paver site, spreading the mix to uniform thickness of 40mm with mechanical paver to the specified grades and cross sections and consolidated by 8-10 tonne Vibratory to the required density etc., including labour for attending to paver to site etc., including hire charges and fuel charges for 20-30 t CMP with bitumen boiler, tipper trucks, Paver Finisher, Vibratory roller and all other tools and plant required, including fuel and all other incidental charges etc., complete as per specification using CMP as per clause 507 of MORTH Rev-5
Providing and laying in position, Standardised Concrete Mix M-25 Grade by insitu machine mix concrete adopting weighing batch method in accordance with IS:456-2000 using 20mm and down graded hard broken granite stone jelly for all RCC items of works with minimum cement content of 350 kglm3 and maximum water cement ratio of 0.50, including admixture (plasticiser / superplasticiser) in recommended proportions as per IS:9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability with about (5.0 Cu.m) 7730 kg. of 20mm machine crushed stone jelly and with about (3.3 Cu.m) 5156 kg. of 10-12mm machine crushed stone jelly and with about (4.79 cu.m’) 7670 kg. of crushed stone sand, but excluding cost of reinforcement grill and fabricating charges, centering and shuttering and also including laying, vibrating with mechanical vibrators, finishing, curing, etc. and providing fixtures like fan clamps in the RCC floor/ roof slabs wherever necessary without claiming extra, etc., complete complying with standard specification and as directed by the SIPCOT Officers. The coarse and fine aggregates to be used should comply with the requirements of IS Standards. (No separate payment will be made by the Department for the excess usage of materials). Foundation and Basement
Supplying, fabricating and placing in position Mild Steel / Ribbed Tor Steel reinforcement grills of all variety like HYSD/CTD/TMTand all grade like Fe 500, Fe550D, Fe 500 D etc., for all RCC works as per design given including cost of steel reinforcement and G.I. binding wire, wastage etc. complete complying with standard specification and as directed by the SIPCOT Officers.(Contractor has to make his own arrangements for the supply of steel reinforcement and binding wire) Upto Plinth / Basement Level
Providing and laying in position, standardised concrete Mix M-20 Grade by insitu machine mix concrete adopting weighing batch method in accordance with IS 456 using 20mm and down graded hard broken granite stone jelly for all RCC items of works with minimum cement content of 325 kg/m3 and maximum water cement ratio of 0.55, including admixture (plasticiser / super plasticiser) in recommended proportions as per IS:9103 to accelerate, retard setting of concrete, improve workability without inspiring strength and durability with about (5 Cu.m) 7730 kg. of 20mm machine crushed stone jelly and with about (3.3 Cu.m) 5156 kg. of 10-12mm machine crushed stone jelly and with about (4.79 cu.m) 7670 kg. of crushed stone sand, but excluding cost ofreinforcement grill and fabricating charges, centering and shuttering and also including laying,vibrating with mechanical vibrators, finishing, curing, etc. and providing fixtures like fan clamps in the RCC floor/ roof slabs wherever necessary without claiming extra, etc.,complete complying with standard specification and as directed by the SIPCOT Officers. The coarse and fine aggregates to be used should comply with the requirements of IS standards. (No separate payment will be made by the Department for the excess usage of materials). Foundation and Basement.
Painting New Plastered Wall Surface with Two finishing coats of
ready mixed (Emulsion) of approved quality and colour over one coat priming coat in all floors including the cost of primer etc., complete complying with standard specification and as directed by the SIPCOT Officers.(The make, quality and colour of paint should be got approved by the Executive Engineer before use on works.)
Part - T - External Water Supply
Supplying, laying and jointing UPVC pipes of Class 5 (having working pressure of 10 kg/sq.cm) conforming to IS 4985- 2000 of approved quality and best variety of the following dia including cutting and fixing UPVC specials using UPVC adhesives (but excluding cost of such specials) in accordance with IS 7634-3 (2003) and fixing into wall with teak wood plugs, PVC clamps and screws making holes on the wall (or) drilling holes in the roof and making good the dismantled portion to original condition with necessary brick work / cement concrete and plastering neatly wherever necessary with necessary scaffolding charges upto 4 metre height above ground level, etc., complete complying with standard specifications. The PVC pipes shall be got approved by Executive Engineer before use on works - External water supply above ground level / Below ground level.
Below Ground Level
25mm dia Below GL
32mm dia Below GL
Part - U - Sewer Network.
Construction of Machineholes using OPC/PPC cement at various depths to invert including earthwork excavation as per SS20B, laying cement concrete in C.M.1:3:6 using Crushed stone sand (Msand) and 40mm jelly for foundation, sinking well kerb below G.L. for 4.5m depth and above, pumping, timbering charges for 2.5m depth and above, stock brick work in C.M.1:3, for 23cm thick wall and over 23cm thick wall, plastering interior with C.M.1:3, 20mm thick and exterior with C.M.1:3, 12mm thick, laying plain cement concrete 1:3:6using 12.0mm to 20mm jelly fixing the frame, providing C.I. steps, machinehole cover using M20 grade concrete 125mm thick and SFRC circular cover and frame heavy duty, benching and channelling including refilling the trench with excavated earth and disposal of surplus earth etc. complete for the following sizes for each machine hole (As per the type design drawing for machinehole)
Up to 1m depth Invert level
1.00m to 1.5m depth
Supply , Delivery, laying & Jointing of DWC Structured Wall Polyethylene Piping Systems (Pipe with online/offline coupler and elastomeric sealing ring) with required specials non-smooth external annular corrugated and smooth internal surface (Double wall) (SN 8 Class) for non-pressure underground sewerage, drainage application generally as per IS-16098 (Part-2) type B.
150mm dia pipe
Supplying, fabricating and placing in position Mild Steel / Ribbed Tor Steel reinforcement grills of all variety like HYSD/CTD/TMTand all grade like Fe 500, Fe550D, Fe 500 D etc., for all RCC works as per design given including cost of steel reinforcement and G.I. binding wire, wastage etc. complete complying with standard specification and as directed by the SIPCOT Officers.(Contractor has to make his own arrangements for the supply of steel reinforcement and binding wire) Upto Plinth / Basement Level
Supplying and fixing in position best approved of BIS quality PVC rain water down fall pipes having a pressure of 4 kg. / sq.cm including cost of neceSORy PVC shoe, PVC bend, cast iron gratings of required diameter and special clamps, brass screws, nails, etc., and fixing of cast iron gratings at junction of parapet and the RCC roof slab including finishing neatly etc., complete. The rate shall be inclusive of cast of removable cast iron grating. The PVC pipe shall be fixed in wall with special type of “U” clamp at the centre of the pipe line in addition to those for more than 3.0 metre pipe length, etc., complete complying with standard specification and as directed by the SIPCOT Officers
Wrapping and coating anti-corrosive treatment for the following under ground MS pipe having one coat of anti corrosive metal primer, one layer of asphalt tar tape wound over the MS Pipe as per standard methods as per standard specifications and as directed by the SIPCOT Officers.
Power point wiring with GI box, socket & switch Wiring with 2 x 2.5 sq.mm. PVC insulated single core unsheathed FRLS copper conductor of 1100 V grade in suitable heavy gauge PVC conduit pipe Concealed in wall and ceiling with PVC accessories with suitable Module GI switch box in flush wall with 1 no. 6A one way module switch and 1 no. 6A 5 pin module socket with module front plate with painting of Suitable colour with continuous earth wire connection of 2.5 sq.mm copper wire and making good of the concealed portion with painting of suitable colour for Concealed etc. Complete as directed and approved by SIPCOT Officers.
Circuit main wiring Supply and run of 2 of 2.5 sq.mm. PVC insulated SC unsheathed FRLS copper conductor of 1100 V grade in suitable PVC conduit pipe concealed in wall and ceiling with continuous earth wire connection of 2.5 sq. mm copper wire with painting of suitable colour etc. Complete as directed and approved by SIPCOT Officers.
Supplying and filling in foundation, basement, etc with filling Stone dust/Quarry dust in layers of not more than 15 cm thick well watered, rammed and consolidated etc. complete complying with standard specification and as directed by the SIPCOT Officers.
IN Ground floor upto 3.6m Ht
In Ground floor
In First floor
8/1962 of anodic film thickness for all sections. All the materials should be got approved by the EE before fixing in position as directed.
Supply of NP3 Class RCC Pipe conforming to IS 458/2003 including cost of pipe as a finished work including all other incidental charges, testing charges including loading, unloading, transport and delivery in good condition at work site etc., complete, as directed by the SIPCOT Officers and as per standard specifications.
Hoisting and fixing of NP3 Class RCC Pipe and Collars in proper gradient including all labour charges and all other incidental charges etc., complete, as directed by the SIPCOT Officers and as per standard specifications. Up to 900mm Dia
Supply, erection, testing and commissioning of Cast iron body and Gun metal or stainless steel internal Non-return valve of following sizes to control one way flow of water to be installed pump room at delivery line and near overhead tank at terrace level near to jockey pump and motor including necessary MS flange of table ‘E’, gaskets, bolts & nuts, etc. as per IS 5312 including conveyance, all incidental charges, neccessary scaffolding and re-doing the dismantled portions to its original condition wherever found neccessary, etc., complete as per standard specification and as directed by the SIPCOT Officers.
Supply, and fixing in position of Fire Fighting Application 63mm dia stainless steel short length Branch Pipe with hexagonal type spray nozzle of 15mm (or) 20mm jet bore. Near every hydrant points including conveyance, all incidental charges, neccessary scaffolding and re-doing the dismantled portions to its original condition wherever found neccessary, etc., complete as per standard specification and as directed by the SIPCOT Officers.
Providing 300mm dia Auger pile to required depth in CC 1:3:6 (one of cement, three of sand, six of hard broken jelly) using 20mm gauge HBG stone jelly excluding cost and fabrication of steel reinforcement grills but including cost of concrete, pouring, Augering, curing, compacting, hire charges for tools and plants etc, complete in all respects and as directed by the SIPCOT Officers
IN First floor
In Foundation and Basement
3.30 - 4.30 Height
4.30 - 5.30 Height
Supplying and fixing of two track aluminium glazed sliding window of anodize alu, natural color matt finish in all floors. All the two shutter with sliding arrangements the bottom section should have gutter arrangements so as to drain the water entering and made with extruded alu section for frame bottom track 61.85mm x 31.75 mm x 1.50mm @ 0.909 kg/m frame top and two slides 61.85 x 31.5mm x 1.50mm @ 0.784 kg/m shutter section top and bottom 40 x 27 mm x 18mm x 1.45 mm @ 0.607 kg/m vertical section 40 x 18 mm x 1.25 mm @ 0.417 kg/m and interlocking vertical section 40 x 18mm x 1.25mm @ 0.417 kg/m with necessary accessories such as rubber beading.
Window W-1 of Size 1.50X1.50Mt
Supply of Fire Fighting Application MS Hose Box to keep two number of hoses and 1 No. of branch pipe with nozzle having proper glass window type double door with universe open key, painted inside white and outside Post Office Red. Near every hydrant point including conveyance, all incidental charges, neccessary scaffolding and re-doing the dismantled portions to its original condition wherever found neccessary, etc., complete as per standard specification and as directed by the SIPCOT Officers.
Supplying and fixing of aluminium anodized natural color matt finish louvered glazed ventilator with the cuter frame of size 63.50x38.10 mm x 1.41 mm @ 0.818 kg/m and louvers with moving arrangements will be made with alu, channel of sizes 60 x 30 x 4 mm @ 1.27 kg/m with necessary glass panes for louvers 4mm thick aluminum "L" angles, screws, nails conveyance, scaffolding if any and power consumption charges required for fabrication wherever necessary with power drill to extent required and made good to the original condition after fixing etc complete complying with relevant standard specification. The aluminium surface is to be anodized with matt finish under electrically controlled condition in accordance with ISI specification 185
Supply, and fixing in position of Fire Fighting Application Hose of 63mm dia of 15 metres length binded by copper wire with 63mm dia stainless steel male and female instantaneous fire fighting special coupling as per IS 901 as directed by the SIPCOT Officers. Near every hydrant points including conveyance, all incidental charges, neccessary scaffolding and re-doing the dismantled portions to its original condition wherever found neccessary etc complete as per standard specification and as directed by the SIPCOT Officers.
Providing and laying in position, Standardised Concrete Mix M-30 Grade by insitu machine mix concr
Weathering course in brick jelly lime concrete using broken brick jelly of size 20mm uniform gauge in pure slaked lime (no crushed stone sand to be used) to the proportion of brick jelly to lime being 32:12.5 by volume and laid over the RCC roof slab in a single layer of required slope and finished by beating the concrete with wooden beaters of approved pattern, keeping the surface constantly wet by sprinkling lime jaggery water, etc., complete as per standard specification and as directed by the deparmental officers.
Supply and kept in position of 9 litres capacity Fire Buckets of 4 Nos. (Tranfomer yard & Electrical room) with Bucket Stand as per standard specifications and as directed by the SIPCOT Officers
Plastering the surface of walls with Cement Mortar 1:3 (One cement and Three plastering sand), 12mm thick in all floors including mortar plasticizer at 200ml per 50Kg of cement used, curing etc., complete complying with standard specification and as directed by the SIPCOT Officers.
Supplying and erecting centering for plane surfaces such as RCC Floor/Roof Beam, Lintels, Cantilever Beams, Bed Blocks etc. with necessary supports and strutting upto 3.60m height in all floors with all cross bracings using MS Sheets made of 10 gauge thick welded with MS angle of Size 25mm x 25mm x 3mm for boarding laid over Steel adjustable Span of Size 2m x 2m(expandable upto 3.60m) and Silver Oak Joists of Size 10 x 5 cm spaced at 50cm to 60cm c/c and supported by Steel Adjustable Telescopic Props of Size 2m x 2m (expandable upto 3.60m) made with outer steel pipe with dia 50mm (3.60mm thick) and inner steel pipe with dia 40mm (2.90mm thick) Spaced at not more than 50 to 60cm c/c, etc complete complying with standard specifications. Steel adjustable span and Steel Adjustable telescopic props shall be provided as directed by the SIPCOT Officers. (Payment for centering shall be given after the concrete is laid).
Supplying and fixing Mild Steel grills for windows, ventilators etc.,complete complying with standard specifications and as directed by the SIPCOT Officers.
Supplying and laying of Interlocking Paver Block Stone 63mm thick Over a 80mm tk base layer of crushed stone sand filling incl. Cost of materials laying and Labour charges etc complete complying with the standard specification and as directed by the SIPCOT Officers.
Earth work excavation for foundation by manual means for Isolated, Combined and Other type foundations in all soils and sub-soils and to full depth as may be directed except in rock requiring blasting inclusive of shoring shuttering, bailing out water wherever necessary and depositing the surplus earth within the compound in places shown by the SIPCOT Officers with an initial lead of 10 mts and initial lift of 2.00mts. and clearing and levelling the site, etc., complete complying with standard specification and as directed by
Supplying and erecting centering for plane surfaces such as RCC Floor Slab, Roof Slab, Loft, Landing Slabs, etc with necessary supports and strutting above 4.90m upto 5.50m height in all floors with all cross bracings using MS Sheets made of 10 gauge thick welded with MS angle of Size 25mm x 25mm x 3mm for boarding laid over steel adjustable span of size 2m x 2m (expandable upto 3.60m) and supported by Steel Adjustable Telescopic Props of Size 3.00m x 3.00m (expandable upto 5.50m) made with outer steel pipe with dia 50mm (3.60mm thick) and inner steel pipe with dia 40mm (2.90mm thick) with Cross bracings provided at two levels at a spacing of 1.80m, etc complete complying with standard specifications. Steel adjustable span and Steel Adjustable telescopic props shall be provided as directed by the SIPCOT Officers (Payment for centering shall be given after the concrete is laid). Above Plinth
ete adopting weighing batch method in accordance with IS:456-2000 using 20mm and down graded hard broken granite stone jelly for all RCC items of works with minimum cement content of 400 kg/m3 and maximum water cement ratio of 0.45, including admixture (plasticiser / superplasticiser) in recommended proportions as per IS:9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability with about (5.0 Cu.m) 7730 kg. of 20mm machine crushed stone jelly and with about (3.3 Cu.m) 5156 kg. of 10-12mm machine crushed stone jelly and with about (4.79 cu.m’) 7670 kg. of crushed stone sand, but excluding cost of reinforcement grill and fabricating charges, centering and shuttering and also including laying, vibrating with mechanical vibrators, finishing, curing, etc. and providing fixtures like fan clamps in the RCC floor/ roof slabs wherever necessary without claiming extra, etc., complete complying with standard specification and as directed by the SIPCOT Officers. The coarse and fine aggregates to be used should comply with the requirements of IS Standards. (No separate payment will be made by the Department for the excess usage of materials). Fourth Floor
Supplying, fabricating and placing in position Mild Steel / Ribbed Tor Steel reinforcement grills of all variety like HYSD/CTD/TMTand all grade like Fe 500, Fe550D, Fe 500 D etc., for all RCC works as per design given including cost of steel reinforcement and G.I. binding wire, wastage etc. complete complying with standard specification and as directed by the SIPCOT Officers.(Contractor has to make his own arrangements for the supply of steel reinforcement and binding wire) Upto Plinth / Basement Level
Supplying and fixing in position best approved of BIS quality PVC rain water down fall pipes having a pressure of 4 kg. / sq.cm including cost of neceSORy PVC shoe, PVC bend, cast iron gratings of required diameter and special clamps, brass screws, nails, etc., and fixing of cast iron gratings at junction of parapet and the RCC roof slab including finishing neatly etc., complete. The rate shall be inclusive of cast of removable cast iron grating. The PVC pipe shall be fixed in wall with special type of “U” clamp at the centre of the pipe line in addition to those for more than 3.0 metre pipe length, etc., complete complying with standard specification and as directed by the SIPCOT Officers
Wrapping and coating anti-corrosive treatment for the following under ground MS pipe having one coat of anti corrosive metal primer, one layer of asphalt tar tape wound over the MS Pipe as per standard methods as per standard specifications and as directed by the SIPCOT Officers.
Power point wiring with GI box, socket & switch Wiring with 2 x 2.5 sq.mm. PVC insulated single core unsheathed FRLS copper conductor of 1100 V grade in suitable heavy gauge PVC conduit pipe Concealed in wall and ceiling with PVC accessories with suitable Module GI switch box in flush wall with 1 no. 6A one way module switch and 1 no. 6A 5 pin module socket with module front plate with painting of Suitable colour with continuous earth wire connection of 2.5 sq.mm copper wire and making good of the concealed portion with painting of suitable colour for Concealed etc. Complete as directed and approved by SIPCOT Officers.
Circuit main wiring Supply and run of 2 of 2.5 sq.mm. PVC insulated SC unsheathed FRLS copper conductor of 1100 V grade in suitable PVC conduit pipe concealed in wall and ceiling with continuous earth wire connection of 2.5 sq. mm copper wire with painting of suitable colour etc. Complete as directed and approved by SIPCOT Officers.
Supplying and filling in foundation, basement, etc with filling Stone dust/Quarry dust in layers of not more than 15 cm thick well watered, rammed and consolidated etc. complete complying with standard specification and as directed by the SIPCOT Officers.
IN Ground floor upto 3.6m Ht
In Ground floor
In First floor
8/1962 of anodic film thickness for all sections. All the materials should be got approved by the EE before fixing in position as directed.
Supply of NP3 Class RCC Pipe conforming to IS 458/2003 including cost of pipe as a finished work including all other incidental charges, testing charges including loading, unloading, transport and delivery in good condition at work site etc., complete, as directed by the SIPCOT Officers and as per standard specifications.
Hoisting and fixing of NP3 Class RCC Pipe and Collars in proper gradient including all labour charges and all other incidental charges etc., complete, as directed by the SIPCOT Officers and as per standard specifications. Up to 900mm Dia
Supply, erection, testing and commissioning of Cast iron body and Gun metal or stainless steel internal Non-return valve of following sizes to control one way flow of water to be installed pump room at delivery line and near overhead tank at terrace level near to jockey pump and motor including necessary MS flange of table ‘E’, gaskets, bolts & nuts, etc. as per IS 5312 including conveyance, all incidental charges, neccessary scaffolding and re-doing the dismantled portions to its original condition wherever found neccessary, etc., complete as per standard specification and as directed by the SIPCOT Officers.
Supply, and fixing in position of Fire Fighting Application 63mm dia stainless steel short length Branch Pipe with hexagonal type spray nozzle of 15mm (or) 20mm jet bore. Near every hydrant points including conveyance, all incidental charges, neccessary scaffolding and re-doing the dismantled portions to its original condition wherever found neccessary, etc., complete as per standard specification and as directed by the SIPCOT Officers.
Providing 300mm dia Auger pile to required depth in CC 1:3:6 (one of cement, three of sand, six of hard broken jelly) using 20mm gauge HBG stone jelly excluding cost and fabrication of steel reinforcement grills but including cost of concrete, pouring, Augering, curing, compacting, hire charges for tools and plants etc, complete in all respects and as directed by the SIPCOT Officers
IN First floor
In Foundation and Basement
3.30 - 4.30 Height
4.30 - 5.30 Height
Supplying and fixing of two track aluminium glazed sliding window of anodize alu, natural color matt finish in all floors. All the two shutter with sliding arrangements the bottom section should have gutter arrangements so as to drain the water entering and made with extruded alu section for frame bottom track 61.85mm x 31.75 mm x 1.50mm @ 0.909 kg/m frame top and two slides 61.85 x 31.5mm x 1.50mm @ 0.784 kg/m shutter section top and bottom 40 x 27 mm x 18mm x 1.45 mm @ 0.607 kg/m vertical section 40 x 18 mm x 1.25 mm @ 0.417 kg/m and interlocking vertical section 40 x 18mm x 1.25mm @ 0.417 kg/m with necessary accessories such as rubber beading.
Window W-1 of Size 1.50X1.50Mt
Supply of Fire Fighting Application MS Hose Box to keep two number of hoses and 1 No. of branch pipe with nozzle having proper glass window type double door with universe open key, painted inside white and outside Post Office Red. Near every hydrant point including conveyance, all incidental charges, neccessary scaffolding and re-doing the dismantled portions to its original condition wherever found neccessary, etc., complete as per standard specification and as directed by the SIPCOT Officers.
Supplying and fixing of aluminium anodized natural color matt finish louvered glazed ventilator with the cuter frame of size 63.50x38.10 mm x 1.41 mm @ 0.818 kg/m and louvers with moving arrangements will be made with alu, channel of sizes 60 x 30 x 4 mm @ 1.27 kg/m with necessary glass panes for louvers 4mm thick aluminum "L" angles, screws, nails conveyance, scaffolding if any and power consumption charges required for fabrication wherever necessary with power drill to extent required and made good to the original condition after fixing etc complete complying with relevant standard specification. The aluminium surface is to be anodized with matt finish under electrically controlled condition in accordance with ISI specification 185
Supply, and fixing in position of Fire Fighting Application Hose of 63mm dia of 15 metres length binded by copper wire with 63mm dia stainless steel male and female instantaneous fire fighting special coupling as per IS 901 as directed by the SIPCOT Officers. Near every hydrant points including conveyance, all incidental charges, neccessary scaffolding and re-doing the dismantled portions to its original condition wherever found neccessary etc complete as per standard specification and as directed by the SIPCOT Officers.
Providing and laying in position, Standardised Concrete Mix M-30 Grade by insitu machine mix concr
Weathering course in brick jelly lime concrete using broken brick jelly of size 20mm uniform gauge in pure slaked lime (no crushed stone sand to be used) to the proportion of brick jelly to lime being 32:12.5 by volume and laid over the RCC roof slab in a single layer of required slope and finished by beating the concrete with wooden beaters of approved pattern, keeping the surface constantly wet by sprinkling lime jaggery water, etc., complete as per standard specification and as directed by the deparmental officers.
Supply and kept in position of 9 litres capacity Fire Buckets of 4 Nos. (Tranfomer yard & Electrical room) with Bucket Stand as per standard specifications and as directed by the SIPCOT Officers
Plastering the surface of walls with Cement Mortar 1:3 (One cement and Three plastering sand), 12mm thick in all floors including mortar plasticizer at 200ml per 50Kg of cement used, curing etc., complete complying with standard specification and as directed by the SIPCOT Officers.
Supplying and erecting centering for plane surfaces such as RCC Floor/Roof Beam, Lintels, Cantilever Beams, Bed Blocks etc. with necessary supports and strutting upto 3.60m height in all floors with all cross bracings using MS Sheets made of 10 gauge thick welded with MS angle of Size 25mm x 25mm x 3mm for boarding laid over Steel adjustable Span of Size 2m x 2m(expandable upto 3.60m) and Silver Oak Joists of Size 10 x 5 cm spaced at 50cm to 60cm c/c and supported by Steel Adjustable Telescopic Props of Size 2m x 2m (expandable upto 3.60m) made with outer steel pipe with dia 50mm (3.60mm thick) and inner steel pipe with dia 40mm (2.90mm thick) Spaced at not more than 50 to 60cm c/c, etc complete complying with standard specifications. Steel adjustable span and Steel Adjustable telescopic props shall be provided as directed by the SIPCOT Officers. (Payment for centering shall be given after the concrete is laid).
Supplying and fixing Mild Steel grills for windows, ventilators etc.,complete complying with standard specifications and as directed by the SIPCOT Officers.
Supplying and laying of Interlocking Paver Block Stone 63mm thick Over a 80mm tk base layer of crushed stone sand filling incl. Cost of materials laying and Labour charges etc complete complying with the standard specification and as directed by the SIPCOT Officers.
Earth work excavation for foundation by manual means for Isolated, Combined and Other type foundations in all soils and sub-soils and to full depth as may be directed except in rock requiring blasting inclusive of shoring shuttering, bailing out water wherever necessary and depositing the surplus earth within the compound in places shown by the SIPCOT Officers with an initial lead of 10 mts and initial lift of 2.00mts. and clearing and levelling the site, etc., complete complying with standard specification and as directed by
Supplying and erecting centering for plane surfaces such as RCC Floor Slab, Roof Slab, Loft, Landing Slabs, etc with necessary supports and strutting above 4.90m upto 5.50m height in all floors with all cross bracings using MS Sheets made of 10 gauge thick welded with MS angle of Size 25mm x 25mm x 3mm for boarding laid over steel adjustable span of size 2m x 2m (expandable upto 3.60m) and supported by Steel Adjustable Telescopic Props of Size 3.00m x 3.00m (expandable upto 5.50m) made with outer steel pipe with dia 50mm (3.60mm thick) and inner steel pipe with dia 40mm (2.90mm thick) with Cross bracings provided at two levels at a spacing of 1.80m, etc complete complying with standard specifications. Steel adjustable span and Steel Adjustable telescopic props shall be provided as directed by the SIPCOT Officers (Payment for centering shall be given after the concrete is laid). Above Plinth
ete adopting weighing batch method in accordance with IS:456-2000 using 20mm and down graded hard broken granite stone jelly for all RCC items of works with minimum cement content of 400 kg/m3 and maximum water cement ratio of 0.45, including admixture (plasticiser / superplasticiser) in recommended proportions as per IS:9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability with about (5.0 Cu.m) 7730 kg. of 20mm machine crushed stone jelly and with about (3.3 Cu.m) 5156 kg. of 10-12mm machine crushed stone jelly and with about (4.79 cu.m’) 7670 kg. of crushed stone sand, but excluding cost of reinforcement grill and fabricating charges, centering and shuttering and also including laying, vibrating with mechanical vibrators, finishing, curing, etc. and providing fixtures like fan clamps in the RCC floor/ roof slabs wherever necessary without claiming extra, etc., complete complying with standard specification and as directed by the SIPCOT Officers. The coarse and fine aggregates to be used should comply with the requirements of IS Standards. (No separate payment will be made by the Department for the excess usage of materials). Fourth Floor
supply and fixing of 300mm (12") sweep AC exhaust fan complete with louvers shutters arrangements for 300mm (12") sweep etc complete as directed and approved by SIPCOT Officers SIPCOT SIPCOT Officers.
Light and fan point wiring Wiring with 2 x1.5 sq.mm. PVC insulated single core unsheathed FRLSH copper conductor of 1100 V grade in suitable PVC rigid pipe Concealed in wall and open as required and ceiling with PVC accessories, ceiling rose and round sheet with flexible hose, Module Gl switch box in flush with wall with 6A one way module switch with module front plate with continuous earth wire connection of 1.5 sq.mm copper wire and making good of the concealed portion with suitable colour for Concealed PVC Light point/fan point etc. Complete as directed and approved by SIPCOT Officers.
Supply & laying of Gl Hot Dip / Powder Coated 16 SWG Cable Tray with 300mm width and 50mm height Ladder type cable tray inside the electrical room etc. complete as directed and approved by SIPCOT Officers and as directed by SIPCOT Officers.
11 KV VCB panel:Design, engineering, manufacture, assembly, supply, erection, installation, testing, and commissioning of an 11 kV, 630A, 25 kA (for 3 seconds) outdoor type HT Vacuum Circuit Breaker (VCB) panel, complete as per specification, shall be both auto and manual operated. The VCB panel shall be suitable for terminating a 3-core 11 kV HT XLPE cable for incoming and outgoing connections, with all necessary accessories and protection as per the standards. It shall be designed for installation in a three-phase, three-wire, 11 kV, 50 Hz
Supplying and Fixing in position of barbed wire fencing using 10 gauge 2 ply 4 pronged barbed wire (Galvanised) etc complete in all respects and as directed by SIPCOT SIPCOT Officers
Part - X - Internal Electrification (Admin Building)
Supplying, fabricating and placing in position Mild Steel / Ribbed Tor Steel reinforcement grills of all variety like HYSD/CTD/TMTand all grade like Fe 500, Fe550D, Fe 500 D etc., for all RCC works as per design given including cost of steel reinforcement and G.I. binding wire, wastage etc. complete complying with standard specification and as directed by the SIPCOT Officers.(Contractor has to make his own arrangements for the supply of steel reinforcement and binding wire) Upto Plinth / Basment Level.
Supply and laying of the following size of PVC armoured LTUG cable in a trench to be excavated at a depth of 0.75 metre putting 0.15 metre layer of sand and covering the three sides of the cable and refilling the earth to make good etc., complete and as directed by SIPCOT SIPCOT Officers.
Part - X - Internal Electrification (Admin Building)
AC distribution network with digital metering system with RS485 port and suitable class-1 CTs& PTs complete with all accessories and erected on the provided foundation as per specification and standards etc, complete as directed and approved by the SIPCOT Officers at the site.
11kV HT TRANSFORMERS Supply, installation, testing & commissioning of 250 kVA, 11 kV/433 V ONAN Outdoor Transformer (As per ISI 1180-Level 1), (Copper winding) Energy Efficient Level - 1 oil immersed ONAN cooled, core type continuous rating, outdoor distribution power transformer with copper winding for voltage ratio 11 KV/433 volts between phases with neutral brought out at LV side. The transformer shall be contained in a mild steel plain & radiator cooled tank, conforming to IS 1180 (Part I) of 2014 with off-load tap switch for ±10% on L.V side and ±5 % on H.V.side. The transformer shall be supplied with all accessories for Plinth Mounted Transformer such as HT & LT Cable Entry Boxes, Copper Extension for Cable End Termination for HT & LT sides, Bucholz Relay, Marshaling Box, Wheels, Channels etc., first filling of oil and consisting of all the fittings and accessories such as Inspection cover, Oil level indicator with minimum and filling level markings, on load tap changing switch with locking device & keys, H.V. Terminals- Bushings, L.V. Terminals cable box, Rating plate, Two earthing terminals, Two lifting hooks etc complete as per IS 1180 (Part I) and as amended thereafter etc. complete as directed and approved by SIPCOT Officers
Supply & Laying of 3C X 185 sq.mm. HT XLPE 11KV insulated aluminium armoured cable in ground up to 1200 mm deep, 500 mm wide cable trench providing sand cushioning before and after laying cable and covering with Layer of sand covering the three sides of the cable with bricks and refilling the earth to make it good as per technical specification, approved drawings and scope of work etc. complete as directed and approved by SIPCOT Officers.
Supplying and making outdoor cable end termination with heat shrinkable jointing kit complete with all accessories including lugs,clamp, tape etc. suitable for size of 185 sq.mm. 3 core HT XLPE 11KV Cable Outdoor Terminations etc. complete as directed and approved by SIPCOT Officers.
Supply & laying of GI Hot Dip / Powder Coated 16 SWG Cable Tray with 300mm width and 50mm height Ladder type cable tray inside the electrical room etc. complete as directed and approved by engine
er incharge and as directed by SIPCOT Officers.
Supply and run of 25mm x 6mm GI Flat Down Conductor with necessary clamps / supports on wall / floor / ground for earth connection etc. complete and as directed by SIPCOT Officers.
LT Cable and End Termination Supply and laying of the following PVC armoured LTUG cable in a trench to be excavated at a depth of 0.75 metre putting 0.15 metre layer of sand and covering the cable completely with bricks and sand and refilling the earth to make good etc. complete and as directed by SIPCOT Officers. From Electrical room VTPNDB to SPNDB-
Providing and fixing of chain link fencing shall be carried out using high-quality PVC-coated 10-gauge galvanized iron (GI) wire, with additional strengthening using 12-gauge GI wire, conforming to IS 2721 and IS 4826 standards. The mesh shall be diamond-shaped with a standard aperture size of 50 mm x 50 mm (or as specified). The fencing shall be properly tensioned, aligned, and installed true to line and level, including the use of suitable nuts, bolts, and washers for secure fixing. All materials and workmanship shall be as per standard specifications, and the work shall be completed in all respects to the satisfaction and as directed by the SIPCOT SIPCOT Officers
Supply and fixing of brass cable gland for following PVC LTUG aluminium armoured cable with earth connection etc.for following sizes of cables etc., complete and as directed by SIPCOT SIPCOT Officers.
LT cable and End Termination Supply and laying of the following PVC armoured LTUG cable in a trench to be excavated at a depth of 0.75 metre putting 0.15 metre layer of sand and covering the cable completely with bricks and sand and refilling the earth to make good etc. complete and as directed by SIPCOT Officers Form Electrical Room VTPNDB to SPNDB.
Supply and fixing of brass cable gland for following PVC LTUG aluminium armoured cable with earth connection etc. For following sizes of cables etc. complete and as directed by SIPCOT Officers
Supply and providing cable end termination of size 3core x 16 sq.mm. Ar. Al. UG cable PVC LTUG aluminium armoured cable with necessary aluminium cable sockets by crimping etc with electrical connection complete etc. complete and as directed by SIPCOT Officers.
Supply and run of 25mm x 6mm Flat Down Conductor with necessary clamps / supports on wall / floor / ground for earth connection etc., complete and as directed by SIPCOT SIPCOT Officers.
Supply and installation of PVC Rigid Pipe 50mm (2") including laying charges in street light pole foundation for power cable entry. Complete, as per standard specification etc., complete and as directed by SIPCOT SIPCOT Officers.
Supply & installation of Cable route markers made of galvanised CI circular 100 mm. dia. with "LT/HT CABLE" markers on same by 30 mm. size letter. The cable marked shall be firmly installed with 450 mm anchoring below ground level etc., complete and as directed by SIPCOT SIPCOT Officers.
Light Fixtures and fan Supply, installation, testing and commissioning of 40W, 4ft LED tube light fitting with cool day light made out of CRCA powder coated body, aluminium reflectors, poly carbonate diffuser, glare free light, suitable for surface mounting including electronic drivers, day light colour LED lamps, inter connecting wiring including accessories all inclusive etc. complete and as directed by SIPCOT SIPCOT Officers.
Supply, installation, testing & Commissioning of Earthing as per PWD standard with an electrode of 2.10 metre class 'B' GI pipe of die not less than 40mm with copper earth plate of size 125mmx50mmx6mm with necessary funnelling arrangements and masonry works and 38mm RCC Cover slab for brick masonry etc. complete and as directed by SIPCOT Officers. Supply and run of 25mm x 6mm Gl Flat Down Conductor with necessary clamps / supports on wall / floor / ground for earth connection etc. complete and as directed by SIPCOT Officers.
Supply and run of 25mm x 6mm GI Flat Down Conductor with necessary clamps / supports on wall / floor / ground for earth connection etc. complete and as directed by SIPCOT Officers.
Supply and run of 2of No.8 SWG GI wire for earth connection with necessary clamps / supports on wall / floor / ground for earth connection etc. complete and as directed by SIPCOT Officers.
supply and fixing of 300mm (12") sweep AC exhaust fan complete with louvers shutters arrangements for 300mm (12") sweep etc complete as directed and approved by SIPCOT Officers SIPCOT SIPCOT Officers.
Light and fan point wiring Wiring with 2 x1.5 sq.mm. PVC insulated single core unsheathed FRLSH copper conductor of 1100 V grade in suitable PVC rigid pipe Concealed in wall and open as required and ceiling with PVC accessories, ceiling rose and round sheet with flexible hose, Module Gl switch box in flush with wall with 6A one way module switch with module front plate with continuous earth wire connection of 1.5 sq.mm copper wire and making good of the concealed portion with suitable colour for Concealed PVC Light point/fan point etc. Complete as directed and approved by SIPCOT Officers.
Supply & laying of Gl Hot Dip / Powder Coated 16 SWG Cable Tray with 300mm width and 50mm height Ladder type cable tray inside the electrical room etc. complete as directed and approved by SIPCOT Officers and as directed by SIPCOT Officers.
11 KV VCB panel:Design, engineering, manufacture, assembly, supply, erection, installation, testing, and commissioning of an 11 kV, 630A, 25 kA (for 3 seconds) outdoor type HT Vacuum Circuit Breaker (VCB) panel, complete as per specification, shall be both auto and manual operated. The VCB panel shall be suitable for terminating a 3-core 11 kV HT XLPE cable for incoming and outgoing connections, with all necessary accessories and protection as per the standards. It shall be designed for installation in a three-phase, three-wire, 11 kV, 50 Hz
DG Set Supply, erection, testing, commissioning of 250kVA, 415 V, 3 phase, 50 Hz, DG Set suitable for synchronisation with diesel engine at 1500 RPM coupled with alternator mounted on a channel Iron base frame, fuel tank of adequate capacity, starting batteries with leads, AMF panel, hospital type silencer, with acoustic enclosure , control panel, inter connecting control cable, cable end termination, including lubrication system, cooling system, all inclusive. DG set should comply with conforming to CPCB IV+ Norms and BIS Specifications or as per the latest environment (protection) rules, etc.complete as directed and approved by SIPCOT Officers.
Part - X - Internal Electrification (Admin Building)
Supplying, fabricating and placing in position Mild Steel / Ribbed Tor Steel reinforcement grills of all variety like HYSD/CTD/TMTand all grade like Fe 500, Fe550D, Fe 500 D etc., for all RCC works as per design given including cost of steel reinforcement and G.I. binding wire, wastage etc. complete complying with standard specification and as directed by the SIPCOT Officers.(Contractor has to make his own arrangements for the supply of steel reinforcement and binding wire) Upto Plinth / Basment Level.
Supply and laying of the following size of PVC armoured LTUG cable in a trench to be excavated at a depth of 0.75 metre putting 0.15 metre layer of sand and covering the three sides of the cable and refilling the earth to make good etc., complete and as directed by SIPCOT SIPCOT Officers.
Part - X - Internal Electrification (Admin Building)
AC distribution network with digital metering system with RS485 port and suitable class-1 CTs& PTs complete with all accessories and erected on the provided foundation as per specification and standards etc, complete as directed and approved by the SIPCOT Officers at the site.
11kV HT TRANSFORMERS Supply, installation, testing & commissioning of 250 kVA, 11 kV/433 V ONAN Outdoor Transformer (As per ISI 1180-Level 1), (Copper winding) Energy Efficient Level - 1 oil immersed ONAN cooled, core type continuous rating, outdoor distribution power transformer with copper winding for voltage ratio 11 KV/433 volts between phases with neutral brought out at LV side. The transformer shall be contained in a mild steel plain & radiator cooled tank, conforming to IS 1180 (Part I) of 2014 with off-load tap switch for ±10% on L.V side and ±5 % on H.V.side. The transformer shall be supplied with all accessories for Plinth Mounted Transformer such as HT & LT Cable Entry Boxes, Copper Extension for Cable End Termination for HT & LT sides, Bucholz Relay, Marshaling Box, Wheels, Channels etc., first filling of oil and consisting of all the fittings and accessories such as Inspection cover, Oil level indicator with minimum and filling level markings, on load tap changing switch with locking device & keys, H.V. Terminals- Bushings, L.V. Terminals cable box, Rating plate, Two earthing terminals, Two lifting hooks etc complete as per IS 1180 (Part I) and as amended thereafter etc. complete as directed and approved by SIPCOT Officers
Supply & Laying of 3C X 185 sq.mm. HT XLPE 11KV insulated aluminium armoured cable in ground up to 1200 mm deep, 500 mm wide cable trench providing sand cushioning before and after laying cable and covering with Layer of sand covering the three sides of the cable with bricks and refilling the earth to make it good as per technical specification, approved drawings and scope of work etc. complete as directed and approved by SIPCOT Officers.
Supplying and making outdoor cable end termination with heat shrinkable jointing kit complete with all accessories including lugs,clamp, tape etc. suitable for size of 185 sq.mm. 3 core HT XLPE 11KV Cable Outdoor Terminations etc. complete as directed and approved by SIPCOT Officers.
Supply & laying of GI Hot Dip / Powder Coated 16 SWG Cable Tray with 300mm width and 50mm height Ladder type cable tray inside the electrical room etc. complete as directed and approved by engine
er incharge and as directed by SIPCOT Officers.
Supply and run of 25mm x 6mm GI Flat Down Conductor with necessary clamps / supports on wall / floor / ground for earth connection etc. complete and as directed by SIPCOT Officers.
LT Cable and End Termination Supply and laying of the following PVC armoured LTUG cable in a trench to be excavated at a depth of 0.75 metre putting 0.15 metre layer of sand and covering the cable completely with bricks and sand and refilling the earth to make good etc. complete and as directed by SIPCOT Officers. From Electrical room VTPNDB to SPNDB-
Providing and fixing of chain link fencing shall be carried out using high-quality PVC-coated 10-gauge galvanized iron (GI) wire, with additional strengthening using 12-gauge GI wire, conforming to IS 2721 and IS 4826 standards. The mesh shall be diamond-shaped with a standard aperture size of 50 mm x 50 mm (or as specified). The fencing shall be properly tensioned, aligned, and installed true to line and level, including the use of suitable nuts, bolts, and washers for secure fixing. All materials and workmanship shall be as per standard specifications, and the work shall be completed in all respects to the satisfaction and as directed by the SIPCOT SIPCOT Officers
Supply and fixing of brass cable gland for following PVC LTUG aluminium armoured cable with earth connection etc.for following sizes of cables etc., complete and as directed by SIPCOT SIPCOT Officers.
LT cable and End Termination Supply and laying of the following PVC armoured LTUG cable in a trench to be excavated at a depth of 0.75 metre putting 0.15 metre layer of sand and covering the cable completely with bricks and sand and refilling the earth to make good etc. complete and as directed by SIPCOT Officers Form Electrical Room VTPNDB to SPNDB.
Supply and fixing of brass cable gland for following PVC LTUG aluminium armoured cable with earth connection etc. For following sizes of cables etc. complete and as directed by SIPCOT Officers
Supply and providing cable end termination of size 3core x 16 sq.mm. Ar. Al. UG cable PVC LTUG aluminium armoured cable with necessary aluminium cable sockets by crimping etc with electrical connection complete etc. complete and as directed by SIPCOT Officers.
Supply and run of 25mm x 6mm Flat Down Conductor with necessary clamps / supports on wall / floor / ground for earth connection etc., complete and as directed by SIPCOT SIPCOT Officers.
Supply and installation of PVC Rigid Pipe 50mm (2") including laying charges in street light pole foundation for power cable entry. Complete, as per standard specification etc., complete and as directed by SIPCOT SIPCOT Officers.
Supply & installation of Cable route markers made of galvanised CI circular 100 mm. dia. with "LT/HT CABLE" markers on same by 30 mm. size letter. The cable marked shall be firmly installed with 450 mm anchoring below ground level etc., complete and as directed by SIPCOT SIPCOT Officers.
Light Fixtures and fan Supply, installation, testing and commissioning of 40W, 4ft LED tube light fitting with cool day light made out of CRCA powder coated body, aluminium reflectors, poly carbonate diffuser, glare free light, suitable for surface mounting including electronic drivers, day light colour LED lamps, inter connecting wiring including accessories all inclusive etc. complete and as directed by SIPCOT SIPCOT Officers.
Supply, installation, testing & Commissioning of Earthing as per PWD standard with an electrode of 2.10 metre class 'B' GI pipe of die not less than 40mm with copper earth plate of size 125mmx50mmx6mm with necessary funnelling arrangements and masonry works and 38mm RCC Cover slab for brick masonry etc. complete and as directed by SIPCOT Officers. Supply and run of 25mm x 6mm Gl Flat Down Conductor with necessary clamps / supports on wall / floor / ground for earth connection etc. complete and as directed by SIPCOT Officers.
Supply and run of 25mm x 6mm GI Flat Down Conductor with necessary clamps / supports on wall / floor / ground for earth connection etc. complete and as directed by SIPCOT Officers.
Supply and run of 2of No.8 SWG GI wire for earth connection with necessary clamps / supports on wall / floor / ground for earth connection etc. complete and as directed by SIPCOT Officers.
Plastering with Cement Mortar 1:3 (One Cement and Three Plastering Sand) 12mm thick mixed with water proofing compound conforming to BIS at 2% by weight of cement used including mortar plasticizer at 200ml per 50Kg of cement used, finsihing, curing, etc., complete in all floors complying with standard specification and as directed by the SIPCOT Officers.
Supplying and laying of Interlocking Paver Block Stone 83mm thick, Over a base layer of 80mm crushed stone sand filling. including cost of Paver,crushed stone sand, laying and Labour charges etc complete complying with the standard specification and as directed by the SIPCOT Officers.
Supplying and fixing in position best approved of BIS quality PVC rain water down fall pipes having a pressure of 4 kg. / sq.cm including cost of neceSORy PVC shoe, PVC bend, cast iron gratings of required diameter and special clamps, brass screws, nails, etc., and fixing of cast iron gratings at junction of parapet and the RCC roof slab including finishing neatly etc., complete. The rate shall be inclusive of cast of removable cast iron grating. The PVC pipe shall be fixed in wall with special type of “U” clamp at the centre of the pipe line in addition to those for more than 3.0 metre pipe length, etc., complete complying with standard specification and as directed by the SIPCOT Officers
Painting the wall two coats with approved weather proof Exterior Emulsion paint over one primer coat on cement plastered wall surface ect., complete complying with standard specification and as directed by the SIPCOT Officers.
Design, supply, installation, testing, and commissioning of an online hydropneumatic pump system with IP65-rated enclosures, including a standby pump arrangement to ensure uninterrupted operation. The system shall be capable of filling a 35,000-liter terrace tank within 45 minutes, requiring a minimum flow rate of approximately 780 liters per minute, with adequate head pressure based on site elevation. The scope includes laying necessary pipelines from the nearest potable water mainline to the terrace tank, using UPVC pipe, and incorporating essential accessories like isolation valves, non-return valves, strainers, pressure gauges, and air release valves. An IP65-rated electrical panel board shall be provided with auto/manual pump controls, overload and dry-run protection, indicator lamps, and pressure switches, connected via copper armoured cables from the electrical room to the panel and from the panel to the pump. The installation shall include RCC foundations, vibration isolation, and all civil, mechanical, and electrical works required for full functionality. The contractor shall ensure the system meets performance criteria including noise levels below 70 dB and automated operation based on pressure and tank level. All materials, labor, transport, testing, documentation, and warranty for a minimum of 12 months shall be included in the quoted cost, and the system must comply with relevant BIS and ISO standards ect., complete complying with standard specification and as directed by the SIPCOT Officers.
Providing additional Strutting to centering of R.C.C slab of all surfaces or any other form works required at site during execution of work for every additional 1 metre height or part there of but not less than 30 cm over the initial 3.60 mt height complete complying with the standard specification and as directed by the SIPCOT Officers.
Supplying and erecting steel centering including necessary supports For plane surfaces such as rectangular or square RCC columns etc. which require only nominal strutting using mild steel sheets made of 10 gauge thick welded with MS angle size 40mm x 40mm x 5 mm and supported by Steel Adjustable Telescopic Props of Size 2m x 2m (expandable upto 3.60m) made with outer steel pipe with dia 50mm (3.60mm thick) and inner steel pipe with dia 40mm (2.90mm thick).etc.. Complete in all floors complying with standard specification. Steel Adjustable telescopic props shall be provided as directed by the SIPCOT Officers. (Payment for centering shall be given after the concrete is laid Above Plinth
rever necessary and depositing the excavated earth with a lead of 10 mts. within the compound in places shown by the SIPCOT Officers and clearing and levelling the site, etc., complete complying with standard specification and as direct-ed by the SIPCOT Officers.
Supplying and fixing Mild Steel grills for windows, ventilators etc.,complete complying with standard specifications and as directed by the SIPCOT Officers.
Plastering with Cement Mortar 1:3 (One Cement and Three Plastering Sand) 12mm thick mixed with water proofing compound conforming to BIS at 2% by weight of cement used including mortar plasticizer at 200ml per 50Kg of cement used, finsihing, curing, etc., complete in all floors complying with standard specification and as directed by the SIPCOT Officers.
Supplying and laying of Interlocking Paver Block Stone 83mm thick, Over a base layer of 80mm crushed stone sand filling. including cost of Paver,crushed stone sand, laying and Labour charges etc complete complying with the standard specification and as directed by the SIPCOT Officers.
Supplying and fixing in position best approved of BIS quality PVC rain water down fall pipes having a pressure of 4 kg. / sq.cm including cost of neceSORy PVC shoe, PVC bend, cast iron gratings of required diameter and special clamps, brass screws, nails, etc., and fixing of cast iron gratings at junction of parapet and the RCC roof slab including finishing neatly etc., complete. The rate shall be inclusive of cast of removable cast iron grating. The PVC pipe shall be fixed in wall with special type of “U” clamp at the centre of the pipe line in addition to those for more than 3.0 metre pipe length, etc., complete complying with standard specification and as directed by the SIPCOT Officers
Painting the wall two coats with approved weather proof Exterior Emulsion paint over one primer coat on cement plastered wall surface ect., complete complying with standard specification and as directed by the SIPCOT Officers.
Design, supply, installation, testing, and commissioning of an online hydropneumatic pump system with IP65-rated enclosures, including a standby pump arrangement to ensure uninterrupted operation. The system shall be capable of filling a 35,000-liter terrace tank within 45 minutes, requiring a minimum flow rate of approximately 780 liters per minute, with adequate head pressure based on site elevation. The scope includes laying necessary pipelines from the nearest potable water mainline to the terrace tank, using UPVC pipe, and incorporating essential accessories like isolation valves, non-return valves, strainers, pressure gauges, and air release valves. An IP65-rated electrical panel board shall be provided with auto/manual pump controls, overload and dry-run protection, indicator lamps, and pressure switches, connected via copper armoured cables from the electrical room to the panel and from the panel to the pump. The installation shall include RCC foundations, vibration isolation, and all civil, mechanical, and electrical works required for full functionality. The contractor shall ensure the system meets performance criteria including noise levels below 70 dB and automated operation based on pressure and tank level. All materials, labor, transport, testing, documentation, and warranty for a minimum of 12 months shall be included in the quoted cost, and the system must comply with relevant BIS and ISO standards ect., complete complying with standard specification and as directed by the SIPCOT Officers.
Providing additional Strutting to centering of R.C.C slab of all surfaces or any other form works required at site during execution of work for every additional 1 metre height or part there of but not less than 30 cm over the initial 3.60 mt height complete complying with the standard specification and as directed by the SIPCOT Officers.
Supplying and erecting steel centering including necessary supports For plane surfaces such as rectangular or square RCC columns etc. which require only nominal strutting using mild steel sheets made of 10 gauge thick welded with MS angle size 40mm x 40mm x 5 mm and supported by Steel Adjustable Telescopic Props of Size 2m x 2m (expandable upto 3.60m) made with outer steel pipe with dia 50mm (3.60mm thick) and inner steel pipe with dia 40mm (2.90mm thick).etc.. Complete in all floors complying with standard specification. Steel Adjustable telescopic props shall be provided as directed by the SIPCOT Officers. (Payment for centering shall be given after the concrete is laid Above Plinth
rever necessary and depositing the excavated earth with a lead of 10 mts. within the compound in places shown by the SIPCOT Officers and clearing and levelling the site, etc., complete complying with standard specification and as direct-ed by the SIPCOT Officers.
Supplying and fixing Mild Steel grills for windows, ventilators etc.,complete complying with standard specifications and as directed by the SIPCOT Officers.
Earth work Open excavation by Mechanical Means for Open Earthwork in all soils and sub-soils and to full depth as may be directed except in rock requiring blasting inclusive of shoring shuttering, bailing out water wherever necessary and depositing the surplus earth within the compound in places shown by the SIPCOT Officers with an initial lead of 100 mts and clearing and levelling including dressing of sides and raming of bottoms etc., complete complying with standard specification and as directed by the SIPCOT Officers. Upto 2.40m Depth
Supplying and filling of Good Earth in foundation, basement, etc with with a average lead of 30 km in conveyed earth in layers of not more than 150mm thick layers well watered, rammed with surface vibrator and consolidated including conveyan
ce charges etc. complete complying with standard specification and as directed by the SIPCOT Officers.
Supplying and filling in foundation, basement, etc with conveyed earth in layers of not more than 150mm thick layers well watered, rammed with surface vibrator and consolidated including conveyance charges etc. complete complying with standard specification and as directed by the SIPCOT Officers.
Supplying and fixing Mild Steel grills for windows, ventilators etc.,complete complying with standard specifications and as directed by the SIPCOT Officers.
Paving pre-polished concrete anti-skid step tiles (Required shape and design) of 20mm thick of approved quality and colour laid in accordance with IS 1443 in Cement Mortar 1:3 (One Cement and Three crushed stone sand), with required Cement Slurry and Mortar Plasticizer, 20mm thick and pointed with white cement mixed with colouring pigment at the rate of 0.40 Kg. / sq.m., curing, etc., complete complying with standard specification and as directed by the SIPCOT Officers. (The make and brand of the tiles should be got approved by Executive Engineer before use on works)
Supplying and erecting centering for plane surfaces such as RCC Floor Slab, Roof Slab, Loft, Landing Slabs, etc with necessary supports and strutting upto 3.60m height in all floors with all cross bracings using MS Sheets made of 10 gauge thick welded with MS angle of Size 25mm x 25mm x 3mm for boarding laid over steel adjustable span of size 2m x 2m (expandable upto 3.60m) and supported by Steel Adjustable Telescopic Props of Size 2m x 2m (expandable upto 3.60m) made with outer steel pipe with dia 50mm (3.60mm thick) and inner steel pipe with dia 40mm (2.90mm thick), etc complete complying with standard specifications. Steel adjustable span and Steel Adjustable telescopic props shall be provided as directed by the SIPCOT Officers. (Payment fo
Earth work Open excavation by Mechanical Means for Open Earthwork in all soils and sub-soils and to full depth as may be directed except in rock requiring blasting inclusive of shoring shuttering, bailing out water wherever necessary and depositing the surplus earth within the compound in places shown by the SIPCOT Officers with an initial lead of 100 mts and clearing and levelling including dressing of sides and raming of bottoms etc., complete complying with standard specification and as directed by the SIPCOT Officers. Upto 2.40m Depth
Supplying and fixing in position 110mm dia best approved of BIS quality PVC rain water down fall pipes having a pressure of 4 kg. / sq.cm including cost of neceSORy PVC shoe, PVC bend, cast iron gratings of required diameter and special clamps, brass screws, nails, etc., and fixing of cast iron gratings at junction of parapet and the RCC roof slab including finishing neatly etc., complete. The rate shall be inclusive of cast of removable cast iron grating. The PVC pipe shall be fixed in wall with special type of “U” clamp at the centre of the pipe line in addition to those for more than 3.0 metre pipe length, etc., complete complying with standard specification and as directed by the SIPCOT Officers
ce charges etc. complete complying with standard specification and as directed by the SIPCOT Officers.
Supplying and filling in foundation, basement, etc with conveyed earth in layers of not more than 150mm thick layers well watered, rammed with surface vibrator and consolidated including conveyance charges etc. complete complying with standard specification and as directed by the SIPCOT Officers.
Supplying and fixing Mild Steel grills for windows, ventilators etc.,complete complying with standard specifications and as directed by the SIPCOT Officers.
Paving pre-polished concrete anti-skid step tiles (Required shape and design) of 20mm thick of approved quality and colour laid in accordance with IS 1443 in Cement Mortar 1:3 (One Cement and Three crushed stone sand), with required Cement Slurry and Mortar Plasticizer, 20mm thick and pointed with white cement mixed with colouring pigment at the rate of 0.40 Kg. / sq.m., curing, etc., complete complying with standard specification and as directed by the SIPCOT Officers. (The make and brand of the tiles should be got approved by Executive Engineer before use on works)
Supplying and erecting centering for plane surfaces such as RCC Floor Slab, Roof Slab, Loft, Landing Slabs, etc with necessary supports and strutting upto 3.60m height in all floors with all cross bracings using MS Sheets made of 10 gauge thick welded with MS angle of Size 25mm x 25mm x 3mm for boarding laid over steel adjustable span of size 2m x 2m (expandable upto 3.60m) and supported by Steel Adjustable Telescopic Props of Size 2m x 2m (expandable upto 3.60m) made with outer steel pipe with dia 50mm (3.60mm thick) and inner steel pipe with dia 40mm (2.90mm thick), etc complete complying with standard specifications. Steel adjustable span and Steel Adjustable telescopic props shall be provided as directed by the SIPCOT Officers. (Payment fo
1 PHASE UPS:Supply erection, testing, commissioning of The UPS shall be 1 Phase, 3 kVA, 230 V,50 Hz , online PWM with IGBT, suitable for continuous duty as per IEC/IS standards, delivering regulated, distortion-free, uninterrupted power with ≥90% efficiency at full load. It shall include comprehensive protections, audible alarms for fault and low-battery, and SMF lead-acid batteries of reputed make providing minimum 1-hour backup at full load. The system shall be complete with input/output MCBs, neutral link, double earthing as per IS 3043, and all required cabling and accessories for safe and reliable operation etc,. complete as directed and approved by SIPCOT Officers.
Supply and run of 33mm x 6mm GI Flat Down Conductor with necessary clamps / supports on wall / floor / ground for earth connection etc. complete and as directed by SIPCOT Officers.
Supply, installation, testing & Commissioning of Earthing as per PWD standard with an electrode of 2.10 metre class 'B' GI pipe of die not less than 40mm with copper earth plate of size 125mmx50mmx6mm with necessary funnelling arrangements and masonry works and 38mm RCC Cover slab for brick masonry etc. complete and as directed by SIPCOT Officers.
Supply and run of 25mm x 6mm tinned copper flat with necessary clamps / supports on wall / floor / ground for earth connection etc. complete and as directed by SIPCOT Officers.
Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer etc. all complete complying with standard specifications and as directed by "SIPCOT" officers..
Supplying and laying of Interlocking Paver Block Stone 63mm thick Over a 80mm tk base layer of crushed stone sand filling incl. Cost of materials laying and Labour charges etc complete complying with the standard specification and as directed by the SIPCOT Officers.
Supplying and filling in foundation, basement, etc with filling Stone dust/Quarry dust in layers of not more than 15 cm thick well watered, rammed and consolidated etc. complete complying with standard specification and as directed by the SIPCOT Officers.
Foundation and basement
In Ground floor
r centering shall be given after the concrete is laid)
Providing and laying in position, standardised concrete Mix M-20 Grade by insitu machine mix concrete adopting weighing batch method in accordance with IS 456 using 20mm and down graded hard broken granite stone jelly for all RCC items of works with minimum cement content of 325 kg/m3 and maximum water cement ratio of 0.55, including admixture (plasticiser / super plasticiser) in recommended proportions as per IS:9103 to accelerate, retard setting of concrete, improve workability without inspiring strength and durability with about (5 Cu.m) 7730 kg. of 20mm machine crushed stone jelly and with about (3.3 Cu.m) 5156 kg. of 10-12mm machine crushed stone jelly and with about (4.79 cu.m) 7670 kg. of crushed stone sand, but excluding cost ofreinforcement grill and fabricating charges, centering and shuttering and also including laying,vibrating with mechanical vibrators, finishing, curing, etc. and providing fixtures like fan clamps in the RCC floor/ roof slabs wherever necessary without claiming extra, etc.,complete complying with standard specification and as directed by the SIPCOT Officers. The coarse and fine aggregates to be used should comply with the requirements of IS standards. (No separate payment will be made by the Department for the excess usage of materials). Foundation and Basement.
Earth work open excavation by manual means in all soils and sub-soils and to full depth as may be directed except in rock requiring blasting inclusive of shoring shuttering, bailing out water wherever necessary and depositing the excavated earth with a lead of 10 mts. within the compound in places shown by the SIPCOT Officers and clearing and levelling the site, etc., complete complying with standard specification and as direct-ed by the SIPCOT Officers. 0 to 2m depth
1 PHASE UPS:Supply erection, testing, commissioning of The UPS shall be 1 Phase, 3 kVA, 230 V,50 Hz , online PWM with IGBT, suitable for continuous duty as per IEC/IS standards, delivering regulated, distortion-free, uninterrupted power with ≥90% efficiency at full load. It shall include comprehensive protections, audible alarms for fault and low-battery, and SMF lead-acid batteries of reputed make providing minimum 1-hour backup at full load. The system shall be complete with input/output MCBs, neutral link, double earthing as per IS 3043, and all required cabling and accessories for safe and reliable operation etc,. complete as directed and approved by SIPCOT Officers.
Supply and run of 33mm x 6mm GI Flat Down Conductor with necessary clamps / supports on wall / floor / ground for earth connection etc. complete and as directed by SIPCOT Officers.
Supply, installation, testing & Commissioning of Earthing as per PWD standard with an electrode of 2.10 metre class 'B' GI pipe of die not less than 40mm with copper earth plate of size 125mmx50mmx6mm with necessary funnelling arrangements and masonry works and 38mm RCC Cover slab for brick masonry etc. complete and as directed by SIPCOT Officers.
Supply and run of 25mm x 6mm tinned copper flat with necessary clamps / supports on wall / floor / ground for earth connection etc. complete and as directed by SIPCOT Officers.
Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer etc. all complete complying with standard specifications and as directed by "SIPCOT" officers..
Supplying and laying of Interlocking Paver Block Stone 63mm thick Over a 80mm tk base layer of crushed stone sand filling incl. Cost of materials laying and Labour charges etc complete complying with the standard specification and as directed by the SIPCOT Officers.
Supplying and filling in foundation, basement, etc with filling Stone dust/Quarry dust in layers of not more than 15 cm thick well watered, rammed and consolidated etc. complete complying with standard specification and as directed by the SIPCOT Officers.
Foundation and basement
In Ground floor
r centering shall be given after the concrete is laid)
Providing and laying in position, standardised concrete Mix M-20 Grade by insitu machine mix concrete adopting weighing batch method in accordance with IS 456 using 20mm and down graded hard broken granite stone jelly for all RCC items of works with minimum cement content of 325 kg/m3 and maximum water cement ratio of 0.55, including admixture (plasticiser / super plasticiser) in recommended proportions as per IS:9103 to accelerate, retard setting of concrete, improve workability without inspiring strength and durability with about (5 Cu.m) 7730 kg. of 20mm machine crushed stone jelly and with about (3.3 Cu.m) 5156 kg. of 10-12mm machine crushed stone jelly and with about (4.79 cu.m) 7670 kg. of crushed stone sand, but excluding cost ofreinforcement grill and fabricating charges, centering and shuttering and also including laying,vibrating with mechanical vibrators, finishing, curing, etc. and providing fixtures like fan clamps in the RCC floor/ roof slabs wherever necessary without claiming extra, etc.,complete complying with standard specification and as directed by the SIPCOT Officers. The coarse and fine aggregates to be used should comply with the requirements of IS standards. (No separate payment will be made by the Department for the excess usage of materials). Foundation and Basement.
Earth work open excavation by manual means in all soils and sub-soils and to full depth as may be directed except in rock requiring blasting inclusive of shoring shuttering, bailing out water wherever necessary and depositing the excavated earth with a lead of 10 mts. within the compound in places shown by the SIPCOT Officers and clearing and levelling the site, etc., complete complying with standard specification and as direct-ed by the SIPCOT Officers. 0 to 2m depth
Sub Total of Total Amount in Column BA (ie. Qty x Unit Rate)
Added GST of 18%
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 0.33 MB
BOQ_744147.xls
BOQ • 0.70 MB
annexure1.pdf
Tender Documents • 0.58 MB
Annexure2.pdf
Tender Documents • 1.21 MB
Download all tender documents and submit your bid